Special Issue "Optical Sensing Technology for Point-of-Care Diagnostics"

A special issue of Biosensors (ISSN 2079-6374). This special issue belongs to the section "Optical and Photonic Biosensors".

Deadline for manuscript submissions: 30 July 2024 | Viewed by 2269

Special Issue Editors

College of Information Science and Engineering, Northeastern University, Shenyang 110819, China
Interests: optical fiber biosensor; lab on a chip; surface plasmon resonance sensor; optical fiber interference sensor; label free biosensor
Special Issues, Collections and Topics in MDPI journals
College of Information Science and Engineering, Northeastern University, Shenyang 110819, China
Interests: optical fiber biochemical sensors; photonic crystal sensors; VOC sensors; point-of-care sensor; intelligent fiber sensor
Special Issues, Collections and Topics in MDPI journals

Special Issue Information

Dear Colleagues,

The success of POC diagnostics heavily depends on the continued development of alternative medical technologies that are cost-effective, yet sensitive and sufficiently accurate.  In this quest, optical technologies play an increasingly important role, as the advances in opto-electronics, fiber optics, optical micro-systems and microfluidics have rapidly transformed the field of biomedical optics.

The field of optical sensors has undergone rapid growth in recent years, with new concepts in miniaturization, multiplex analysis, photonic structures, and optically responsive materials appearing regularly. At the same time, the fields of genomics, proteomics, and metabolomics are providing a wealth of new molecules for detection purposes.

This Special Issue will highlight research focused on the development and use of new optical sensors for medical diagnostics, biomedical research, and related endeavors. Papers that describe new optical diagnostics methods for point-of-care, field-use, and resource-limited applications are encouraged, as are those that report novel assays, multiplex testing systems, “lab-on-a-chip” sensors, and spectroscopic methods.

Dr. Xuegang Li
Prof. Dr. Yanan Zhang
Guest Editors

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All submissions that pass pre-check are peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. Biosensors is an international peer-reviewed open access monthly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 2700 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Keywords

  • optical sensing
  • point-of-care diagnostics
  • integrated photonics for sensing
  • plasmonics
  • multiplex detection
  • spectroscopy
  • lab-on-a-chip devices

Published Papers (2 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Research

16 pages, 2074 KiB  
Article
Surface Functionalised Optical Fibre for Detection of Hydrogen Sulphide
Biosensors 2023, 13(11), 949; https://doi.org/10.3390/bios13110949 - 24 Oct 2023
Viewed by 685
Abstract
Dysregulated production of hydrogen sulphide in the human body has been associated with various diseases including cancer, underlining the importance of accurate detection of this molecule. Here, we report the detection of hydrogen sulphide using fluorescence-emission enhancement of two 1,8-naphthalimide fluorescent probes with [...] Read more.
Dysregulated production of hydrogen sulphide in the human body has been associated with various diseases including cancer, underlining the importance of accurate detection of this molecule. Here, we report the detection of hydrogen sulphide using fluorescence-emission enhancement of two 1,8-naphthalimide fluorescent probes with an azide moiety in position 4. One probe, serving as a control, featured a methoxyethyl moiety through the imide to evaluate its effectiveness for hydrogen sulphide detection, while the other probe was modified with (3-aminopropyl)triethoxysilane (APTES) to enable direct covalent attachment to an optical fibre tip. We coated the optical fibre tip relatively homogeneously with the APTES-azide fluorophore, as confirmed via x-ray photoelectron spectroscopy (XPS). The absorption and fluorescence responses of the control fluorophore free in PBS were analysed using UV-Vis and fluorescence spectrophotometry, while the fluorescence emission of the APTES-azide fluorophore-coated optical fibres was examined using a simple, low-cost optical fibre-based setup. Both fluorescent probes exhibited a significant increase (more than double the initial value) in fluorescence emission upon the addition of HS when excited with 405 nm. However, the fluorescence enhancement of the coated optical fibres demonstrated a much faster response time of 2 min (time for the fluorescence intensity to reach 90% of its maximum value) compared to the control fluorophore in solution (30 min). Additionally, the temporal evolution of fluorescence intensity of the fluorophore coated on the optical fibre was studied at two pH values (7.4 and 6.4), demonstrating a reasonable overlap and confirming the compound pH insensitivity within this range. The promising results from this study indicate the potential for developing an optical fibre-based sensing system for HS detection using the synthesised fluorophore, which could have significant applications in health monitoring and disease detection. Full article
(This article belongs to the Special Issue Optical Sensing Technology for Point-of-Care Diagnostics)
Show Figures

Graphical abstract

12 pages, 1976 KiB  
Article
Ultrasensitive and Rapid Visual Detection of Escherichia coli O157:H7 Based on RAA-CRISPR/Cas12a System
Biosensors 2023, 13(6), 659; https://doi.org/10.3390/bios13060659 - 16 Jun 2023
Cited by 1 | Viewed by 1129
Abstract
Escherichia coli (E. coli) O157:H7 is a major foodborne and waterborne pathogen that can threaten human health. Due to its high toxicity at low concentrations, it is crucial to establish a time-saving and highly sensitive in situ detection method. Herein, we [...] Read more.
Escherichia coli (E. coli) O157:H7 is a major foodborne and waterborne pathogen that can threaten human health. Due to its high toxicity at low concentrations, it is crucial to establish a time-saving and highly sensitive in situ detection method. Herein, we developed a rapid, ultrasensitive, and visualized method for detecting E. coli O157:H7 based on a combination of Recombinase-Aided Amplification (RAA) and CRISPR/Cas12a technology. The CRISPR/Cas12a-based system was pre-amplified using the RAA method, which showed high sensitivity and enabled detecting as low as ~1 CFU/mL (fluorescence method) and 1 × 102 CFU/mL (lateral flow assay) of E. coli O157:H7, which was much lower than the detection limit of the traditional real-time PCR technology (103 CFU/mL) and ELISA (104~107 CFU/mL). In addition, we demonstrated that this method still has good applicability in practical samples by simulating the detection in real milk and drinking water samples. Importantly, our RAA-CRISPR/Cas12a detection system could complete the overall process (including extraction, amplification, and detection) within 55 min under optimized conditions, which is faster than most other reported sensors, which take several hours to several days. The signal readout could also be visualized by fluorescence generated with a handheld UV lamp or a naked-eye-detected lateral flow assay depending on the DNA reporters used. Because of the advantages of being fast, having high sensitivity, and not requiring sophisticated equipment, this method has a promising application prospect for in situ detection of trace amounts of pathogens. Full article
(This article belongs to the Special Issue Optical Sensing Technology for Point-of-Care Diagnostics)
Show Figures

Figure 1

Back to TopTop