Advanced Structural Analysis for Earthquake-Resistant Design of Buildings

A special issue of Applied Sciences (ISSN 2076-3417). This special issue belongs to the section "Civil Engineering".

Deadline for manuscript submissions: 30 April 2024 | Viewed by 7177

Special Issue Editors


E-Mail Website
Guest Editor
1. Faculty of Science and Technology, Norwegian University of Life Sciences, Ås, Norway
2. Department of Civil, Construction-Architectural and Environmental Engineering (DICEAA), University of L’Aquila, 67100 L’Aquila, Italy
Interests: structural analysis; earthquake engineering; structural dynamics; finite element analysis

E-Mail Website
Guest Editor
Norwegian Institute of Wood and Technology, Oslo, Norway
Interests: structural analysis; earthquake engineering; structural dynamics; finite element analysis

Special Issue Information

Dear Colleagues,

The use of computers has led to a substantial change in the design and seismic analysis of structures. Strongly approximate procedures, foreseen by the previous regulations, are considered superseded by the most recent regulations. In particular, nonlinear dynamic analyses are increasingly used in the seismic design of complex structures. Buildings experience significant inelastic deformations under large earthquakes; the analysis method is able to account for strength and stiffness deterioration, and may represent the structural behavior more realistically.

However, nonlinear analyses require significantly more effort and expertise in term of the material behavior. What is the trade-off between accuracy and computational cost in seismic response simulations? Are nonlinear dynamic analyzes always necessary? What is the degree of the conventionality of approximate methods, such as linear and nonlinear statics and linear dynamics? Recently, many scholars have tackled the analysis of the seismic response of structures from both a theoretical (development of new methods) and applicational point of view. This Special Issue intends to collect recent research contributions on the seismic response of structures, from method investigations to noteworthy case studies. The novel methods will include structural analysis methods and numerical modelling approaches for the seismic design and assessment of buildings based on deterministic and probabilistic approaches. Original contributions containing fundamental and applied research, case studies, or state of the art are encouraged to be submitted to this Special Issue.

Dr. Angelo Aloisio
Dr. Dag Pasquale Pasca
Guest Editors

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All submissions that pass pre-check are peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. Applied Sciences is an international peer-reviewed open access semimonthly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 2400 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Keywords

  • seismic design
  • structural dynamics
  • structural analysis
  • seismic retrofitting

Published Papers (7 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Research

28 pages, 17200 KiB  
Article
Geotechnical and Structural Damages Caused by the 2023 Kahramanmaraş Earthquakes in Gölbaşı (Adıyaman)
by Fahriye Akar, Ercan Işık, Fatih Avcil, Aydın Büyüksaraç, Enes Arkan and Rabia İzol
Appl. Sci. 2024, 14(5), 2165; https://doi.org/10.3390/app14052165 - 05 Mar 2024
Cited by 1 | Viewed by 627
Abstract
On 6 February 2023, two independent earthquake pairs on the East Anatolian Fault Zone, with epicenters in Pazarcık (Mw = 7.7) and Elbistan (Mw = 7.6) districts of Kahramanmaraş province, caused great destruction. Adıyaman and Gölbaşı districts of this city are among the [...] Read more.
On 6 February 2023, two independent earthquake pairs on the East Anatolian Fault Zone, with epicenters in Pazarcık (Mw = 7.7) and Elbistan (Mw = 7.6) districts of Kahramanmaraş province, caused great destruction. Adıyaman and Gölbaşı districts of this city are among the settlements most affected by the earthquake. Especially in the district where geotechnical damages are most observed, the destructive effects of earthquakes have been clearly observed in buildings with different structural systems. In this study, information is given about the earthquakes that hit the region and the fault zone where the earthquakes occur. Geotechnical and structural damages occurring in the villages and center of the district were evaluated within the scope of earthquakes and structural engineering. It can be stated that damages observed in the district center are generally caused by soil–structure interaction problems. The fact that masonry structures, which are widely used in rural areas, do not benefit from any engineering services has an impact on the level of damage. The main reason for the damages occurring in the reinforced concrete structures in the district is the reinforced concrete system that is not designed properly or not built in accordance with the design. This case study demonstrated the importance of earthquake–soil–structure interactions in line with earthquake-resistant building design principles. Full article
Show Figures

Figure 1

30 pages, 11318 KiB  
Article
Seismic Performance Evaluation of Reinforced Concrete Buildings Retrofitted with a New Concrete Filled Tube Composite Strengthening System
by Ho-Jin Baek, Ju-Seong Jung, Kang-Seok Lee and Bok-Gi Lee
Appl. Sci. 2023, 13(24), 13231; https://doi.org/10.3390/app132413231 - 13 Dec 2023
Viewed by 695
Abstract
This study proposes a concrete-filled tube composite strengthening system (CCSS), which is a new concept that can improve and supplement the vulnerability of existing CFT seismic strengthening methods. The CCSS seismic reinforcement method is easy to construct and integrates with the existing frame [...] Read more.
This study proposes a concrete-filled tube composite strengthening system (CCSS), which is a new concept that can improve and supplement the vulnerability of existing CFT seismic strengthening methods. The CCSS seismic reinforcement method is easy to construct and integrates with the existing frame and reinforcement. It is one of the seismic strengthening methods that allows the simple calculation of the required amount of seismic reinforcement and can efficiently increase the strength when applied to existing reinforced concrete (R/C) buildings with non-seismic details dominated by shear failure. To examine the seismic safety of the proposed CCSS, two framework specimens were prepared based on an existing R/C building with non-seismic details. A pseudo-dynamic test was conducted on the unreinforced framework specimen and the framework specimen reinforced with CCSS to verify the seismic strengthening effect of applying CCSS to the existing R/C framework, i.e., in terms of the load–displacement characteristics and seismic response control capability. Based on the pseudo-dynamic test results, restoration of the force characteristics was proposed for the nonlinear dynamic analysis of the building reinforced with CCSS. Nonlinear dynamic analysis was conducted based on the proposed restoration of the force characteristics, and the results were compared with the pseudo-dynamic test results. Finally, for the commercialization of CCSS, nonlinear dynamic analysis was conducted on the existing whole R/C building with non-seismic details that was reinforced with CCSS. The seismic strengthening effect was then verified by examining the seismic response load, displacement characteristics, and the degree of seismic damage to the members based on the ductility ratio before and after seismic strengthening. The study results show that under a design basis earthquake with a magnitude of 200 cm/s2, the unreinforced R/C building exhibits shear failure, and light seismic damage is expected on the CCSS-reinforced building. Full article
Show Figures

Figure 1

17 pages, 5802 KiB  
Article
Nonlinear Static Analysis for Seismic Evaluation of Existing RC Hospital Building
by Kevin Karanja Kuria and Orsolya Katalin Kegyes-Brassai
Appl. Sci. 2023, 13(21), 11626; https://doi.org/10.3390/app132111626 - 24 Oct 2023
Cited by 1 | Viewed by 1377
Abstract
Nonlinear Static Analysis otherwise known as pushover analysis will be used in this study to evaluate the seismic performance of an existing reinforced concrete (RC) hospital structure. This method aids in determining the structure’s ability to withstand lateral loads and calculating its local [...] Read more.
Nonlinear Static Analysis otherwise known as pushover analysis will be used in this study to evaluate the seismic performance of an existing reinforced concrete (RC) hospital structure. This method aids in determining the structure’s ability to withstand lateral loads and calculating its local and global deformation requirements. The study begins with a thorough analysis of the geometry, materials, and structural elements of the structure, followed by a review of pertinent building regulations and codes. A finite element model in three dimensions of the hospital building is created, encapsulating the main features of the structure’s behavior under seismic loading. The lateral force method of analysis and static pushover analysis is then carried out and compared, and the findings are used to pinpoint crucial weak places, potential failure mechanisms, and regions needing additional research or fortification. Recommendations are given to improve the seismic performance of the current RC hospital building based on the pushover analysis’s findings. These adjustments can be made to the structural system via retrofitting techniques or to non-structural elements. For engineers, architects, and legislators concerned with the seismic assessment and renovation of hospital buildings and other crucial infrastructure, the findings from this study are valuable. Full article
Show Figures

Figure 1

32 pages, 30270 KiB  
Article
Analytic Investigation of Hooked Stirrups on Seismic Behavior of Reinforced Concrete 3D Frame Buildings
by Ibrahim Baran Karasin
Appl. Sci. 2023, 13(20), 11590; https://doi.org/10.3390/app132011590 - 23 Oct 2023
Cited by 1 | Viewed by 1182
Abstract
Ensuring the safety and stability of buildings during earthquakes is of utmost importance. This can be achieved by assessing the seismic performance of reinforced concrete structures with consideration of design details. This study focused on the seismic behavior of reinforced concrete buildings by [...] Read more.
Ensuring the safety and stability of buildings during earthquakes is of utmost importance. This can be achieved by assessing the seismic performance of reinforced concrete structures with consideration of design details. This study focused on the seismic behavior of reinforced concrete buildings by comparing the effects of two different types of stirrups, namely those with a 135° angled end-hook shape and straight hooks, with variation of concrete strength. Pushover analysis of a sample building was performed to determine the effect of hook shape on stirrup reinforcement with a constant volumetric ratio for various concrete strength classes. The results of the analysis indicated significant differences in concrete strength and seismic behavior between the two stirrup configurations. The hooked stirrups demonstrated superior energy dissipation capability and ductility, which led to better seismic performance compared to unhooked stirrups across varying levels of concrete strength. To extend the investigation, the study compared the Mander et al., Kent–Scott–Park, and Kappos–Konstantinidis concrete models with different concrete classes (C50-C25-C20-C16-C10). The findings emphasized the importance of stirrup configuration in the design of earthquake-resistant structures. The study concluded that RC structural performance with the 135-degree hooked concrete members exhibited much better behavior of the 90-degree members for the various concrete strength. In this way, it has been revealed the arrangement and detailing of reinforcement in the construction beams and columns improves the governing effect on seismic structural performance. Full article
Show Figures

Figure 1

37 pages, 5979 KiB  
Article
Utilizing Artificial Neural Networks and Random Forests to Forecast the Dynamic Amplification Factors of Non-Structural Components
by P. Vyshnavi, S. P. Challagulla, Musa Adamu, Felipe Vicencio, Mohammed Jameel, Yasser E. Ibrahim and Omar Shabbir Ahmed
Appl. Sci. 2023, 13(20), 11329; https://doi.org/10.3390/app132011329 - 16 Oct 2023
Viewed by 1057
Abstract
Soft stories in buildings are well-known to present structural vulnerabilities during seismic events, and the failure of non-structural components (NSCs) has been evident in past earthquakes, along with structural damage. This study seeks to investigate how the presence of a soft story in [...] Read more.
Soft stories in buildings are well-known to present structural vulnerabilities during seismic events, and the failure of non-structural components (NSCs) has been evident in past earthquakes, along with structural damage. This study seeks to investigate how the presence of a soft story in a building affects the criteria for elastic floor acceleration. The soft story is assumed to be at the top, middle, and bottom levels of the structure. To comprehend the behavior of NSCs, the researchers analyze the floor response spectra (FRSs) and component acceleration amplification. Remarkably, the results reveal that the position of the soft story strongly influences the floor response spectra, with structures featuring a middle soft story showing the most significant amplification of component acceleration. In constructing the FRSs, the component dynamic amplification factors (CDAFs) play a vital role as they accurately illustrate how NSCs amplify floor vibrations. Consequently, the study delves into exploring machine learning (ML) models like artificial neural networks (ANNs) and random forest (RF) to map the intricate relationship between CDAFs, the dynamic characteristics of the building, and the behavior of NSCs. Upon comparison of the two models, the random forest model emerges as the superior method in predicting the CDAFs. Full article
Show Figures

Figure 1

26 pages, 9381 KiB  
Article
The Effect of Material Quality on Buildings Moderately and Heavily Damaged by the Kahramanmaraş Earthquakes
by Başak Zengin and Fatih Aydin
Appl. Sci. 2023, 13(19), 10668; https://doi.org/10.3390/app131910668 - 25 Sep 2023
Cited by 7 | Viewed by 1073
Abstract
On 6 February 2023, two major earthquakes occurred in the Turkish province of Kahramanmaraş. The first earthquake with a magnitude of Mw 7.7 occurred in the center of Kahramanmaras, while the second earthquake with a magnitude of Mw 7.5 occurred in the region [...] Read more.
On 6 February 2023, two major earthquakes occurred in the Turkish province of Kahramanmaraş. The first earthquake with a magnitude of Mw 7.7 occurred in the center of Kahramanmaras, while the second earthquake with a magnitude of Mw 7.5 occurred in the region of Elbistan. These earthquakes caused heavy damage and loss of life in the affected regions. In particular, the Elbistan region experienced both earthquakes with great severity. Following the earthquakes, damage analyses were carried out on the earthquake-affected structures in this region. In the region, 1045 buildings were destroyed, 2640 buildings were heavily damaged, and 463 buildings were moderately damaged by the earthquakes. In this study, the relation between the material quality and the damage status of the affected buildings in the Elbistan region was investigated. A total of 20 buildings with heavy and moderate damage, built both before and after the year 2000, were selected for analysis. Samples were taken from these buildings, and the compressive strength values of the samples were obtained. Further, in situ experiments featuring the Schmidt and UPV tests were performed in the buildings. The results found that the buildings lacked adequate concrete strength. In particular, the post-2000 structures recorded concrete strength values below the established standard. This study proves the necessity of following established regulations in the design and construction of buildings in earthquake-prone zones, especially with respect to the construction materials used. Full article
Show Figures

Figure 1

24 pages, 5309 KiB  
Article
Dynamic Response Analysis of Mega-Sub Isolated Structures under Multiaxial Earthquakes
by Xueyuan Yan, Jian Liu, Weiyu Lin, Guoguan Lan and Huimin Mao
Appl. Sci. 2023, 13(15), 8692; https://doi.org/10.3390/app13158692 - 27 Jul 2023
Viewed by 550
Abstract
With the use of seismic isolation techniques on mega-sub structures, several scholars have carried out research on them. However, little research has been carried out on mega-sub isolated structures under multiaxial earthquakes. There have been instances in actual engineering where the peak vertical [...] Read more.
With the use of seismic isolation techniques on mega-sub structures, several scholars have carried out research on them. However, little research has been carried out on mega-sub isolated structures under multiaxial earthquakes. There have been instances in actual engineering where the peak vertical acceleration exceeded the horizontal direction, and the vertical seismic component will also amplify the dynamic response of the structure in the horizontal direction, so in practice, it is necessary to consider the influence of the vertical component of the earthquake on the structure. To investigate the dynamic response of mega-sub isolated structures under unidirectional earthquake and coupled earthquake, this paper used numerical methods to analyze the influences of the horizontal and vertical damping ratio of the isolation layer, the horizontal and vertical frequency ratio of the main substructure, and the mass ratio of the main substructure on the acceleration and displacement of the main and substructure. The optimum parameter values are finally achieved by analytical calculations, which provide a basis for further optimization and practical design of the structure. Finally, the collision between the main and sub-structures in the mega-sub isolated structure was simulated, and the influences of the peak ground motion, main and subframe spacing, vertical seismic component, and sub-structure height on the collision force and acceleration were analyzed. It was shown that the conflict of the main and sub-structures generates instantaneous, large collision forces, which also instantaneously amplify the acceleration and base shear force response, which should be avoided in practical engineering. Full article
Show Figures

Figure 1

Back to TopTop