State-of-the-Art Energy Conversion and Storage

A special issue of Processes (ISSN 2227-9717). This special issue belongs to the section "Energy Systems".

Deadline for manuscript submissions: closed (15 April 2024) | Viewed by 10180

Special Issue Editors


E-Mail Website
Guest Editor
Department of Energy and Power Engineering, Tsinghua University, Beijing 100084, China
Interests: hydraulic energy storage; nuclear energy; fluid mechanics; multidisciplinary design optimization; pump-turbine
School of Energy and Power Engineering, Jiangsu University, Zhenjiang 212013, China
Interests: biomass conversion; renewable energy technologies; energy conversion; chemical looping; CO2 capture and utilization

E-Mail Website
Guest Editor
Department of Energy and Power Engineering, Tsinghua University, Beijing 100084, China
Interests: complex flow and vortex dynamics in pump turbine
Special Issues, Collections and Topics in MDPI journals

E-Mail Website
Guest Editor
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210024, China
Interests: renewable energy technologies; new energy machinery manufacturing; surface processing of biomimetic; micro-nano structure

Special Issue Information

Dear Colleagues,

With the shortage of energy and the change of climate, renewable energy has become the focus of society today. Renewable energy includes solar energy, water energy, wind energy, biomass energy, tidal energy, geothermal energy, etc. This Special Issue on “State-of-the-Art Energy Conversion and Storage” intends to present novel examples of new theories, new concepts and new technologies for all types of renewable energy. Topics include, but are not limited to:

  • Wind energy, solar energy, hydro energy, pumped storage, nuclear energy;
  • Biomass Conversion, Renewable Energy Technologies, Energy Conversion and storage.
  • Wind-solar-water-storage integration, wind-solar-hydropower generation;
  • Advanced nuclear reactor technology, Nuclear Engineering;
  • Experimental measurement, numerical simulation, sustainable energy systems and policies.

Dr. Yonggang Lu
Dr. Zhong Ma
Dr. Xijie Song
Dr. Yanjie Yuan
Guest Editors

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All submissions that pass pre-check are peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. Processes is an international peer-reviewed open access monthly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 2400 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Keywords

  • renewable energy
  • wind energy
  • solar energy
  • hydro energy
  • biomass conversion
  • nuclear energy
  • pumped storage
  • renewable energy technologies

Published Papers (10 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Research

Jump to: Review

18 pages, 2263 KiB  
Article
Mitigation of Renewable Energy Source Production Variability in Residential Stock through Small-Scale Gas–Liquid Energy Storage Technology Application
by Andrea Vallati, Miriam Di Matteo, Laura Pompei, Fabio Nardecchia and Costanza Vittoria Fiorini
Processes 2024, 12(4), 655; https://doi.org/10.3390/pr12040655 - 25 Mar 2024
Viewed by 610
Abstract
Despite renewable energy source integration being a well-established requirement in international policies, energy systems still face some unresolved issues, including the intermittence of production. To tackle this problem, a viable solution could comprise the off-peak storage of electricity production excess, to be consumed [...] Read more.
Despite renewable energy source integration being a well-established requirement in international policies, energy systems still face some unresolved issues, including the intermittence of production. To tackle this problem, a viable solution could comprise the off-peak storage of electricity production excess, to be consumed later during peak-load hours. The transition from the diffuse pattern of centralized generation to the distributed model, involving energy communities, suggests an additional aspect to manage: the spatial constraints of systems for domestic applications. Compressed-air energy storage represents a promising Power-to-Power technology for small-scale energy integration. This study proposes the application of a gas–liquid energy storage system (GLES) in a residential building, using renewable energy excess from a photovoltaic (PV) array. The performance of the proposed system, whose operation involves the compression of the gaseous mass through a piston operated by mineral oil, was evaluated through energy analysis performed simulating the devices and their coupling with the load profiles of the building. The thermodynamic model of storage was validated using data from an experimental campaign on a prototype. A sensitivity study, acting on the features of the system, such as the compression rate and vessel size, allowed us to compare the absorbed PV energy excess, the coverage of the building energy demand during the expansion phase, and the electrical efficiency of a daily cycle. The results obtained, together with the related economic analysis, were used to quantify the market potential of the proposed solution, to be exploited as a mechanical alternative to conventional electric batteries in dwellings. Full article
(This article belongs to the Special Issue State-of-the-Art Energy Conversion and Storage)
Show Figures

Figure 1

19 pages, 5953 KiB  
Article
Flow Characteristics Analysis of a 1 GW Hydraulic Turbine at Rated Condition and Overload Operation Condition
by Chengming Liu, Siyuan Wu, Xingxing Huang, Shuai Zhang, Lingjiu Zhou, Tianli Hu and Zhengwei Wang
Processes 2024, 12(2), 255; https://doi.org/10.3390/pr12020255 - 24 Jan 2024
Viewed by 491
Abstract
Flow stability is extremely important for hydraulic turbines, especially for 1 GW hydraulic turbines, and has a strong impact on mesh stability. However, turbines often operate under non-design conditions, and current research on this aspect is still lacking. So a model of the [...] Read more.
Flow stability is extremely important for hydraulic turbines, especially for 1 GW hydraulic turbines, and has a strong impact on mesh stability. However, turbines often operate under non-design conditions, and current research on this aspect is still lacking. So a model of the fluid domains of a high-quality installed 1 GW Francis turbine was established to investigate the flow characteristics of the turbine and fluid domains. CFD simulations of a 1 GW Francis turbine under rated load and overload operation conditions were performed. According to simulation results, when the turbine is under the overload operation condition, the internal flow stability of the 1 GW hydraulic turbine can be obviously different from that of the rated load. In the overload condition, the flow field is more turbulent and a large number of vortices are generated in the draft tube, resulting in significant changes in pressure, flow rate, and output. In order to improve calculation accuracy, a pure clearance model containing only clearances and pressure balance pipes was established. The results of the full flow channel and pure clearance were compared. It was found that under the rated operating condition and the overload condition, compared with the pure clearance model, the axial force of the runner calculated by the full flow channel model is approximately 2–7% biased, the radial force is biased by approximately 7–8%, and the leakage flow is smaller. Full article
(This article belongs to the Special Issue State-of-the-Art Energy Conversion and Storage)
Show Figures

Figure 1

21 pages, 5294 KiB  
Article
Centrifugal Pump Cavitation Fault Diagnosis Based on Feature-Level Multi-Source Information Fusion
by Mengbin Song, Yifan Zhi, Mengdong An, Wei Xu, Guohui Li and Xiuli Wang
Processes 2024, 12(1), 196; https://doi.org/10.3390/pr12010196 - 16 Jan 2024
Viewed by 752
Abstract
In nuclear power systems, centrifugal pumps often need to operate under extreme conditions. However, accurately determining the cavitation status of centrifugal pumps under such extreme conditions is challenging. To improve the recognition accuracy of the three statuses of non-cavitation, incipient cavitation, and severe [...] Read more.
In nuclear power systems, centrifugal pumps often need to operate under extreme conditions. However, accurately determining the cavitation status of centrifugal pumps under such extreme conditions is challenging. To improve the recognition accuracy of the three statuses of non-cavitation, incipient cavitation, and severe cavitation while improving the anti-interference capability of the monitoring system, this study extracted cavitation features from centrifugal pumps’ motor current and vibration signals under three different operational conditions. It fused the features using feature-level multi-source information fusion (MSIF) based on the backpropagation neural network (BPNN) or support vector machine (SVM) to construct a cavitation status recognition model and analyzed the results to compare with those of recognition without information fusion. The results show that, compared with one signal source, MSIF can significantly improve the recognition accuracy of cavitation statuses. Combined current and pump casing axial monitoring based on the BPNN is the optimal scheme, with an overall recognition accuracy of 97.3% for all operational conditions, compared to 73.9% for the single current signal and 89.3% for the single casing axial vibration signal. These research results can guide the monitoring of cavitation statuses in practical engineering, as well as timely intervention at incipient cavitations to reduce structural damage to centrifugal pumps and prolong service life. Full article
(This article belongs to the Special Issue State-of-the-Art Energy Conversion and Storage)
Show Figures

Figure 1

17 pages, 9580 KiB  
Article
Analysis of Cavitation-Induced Unsteady Flow Conditions in Francis Turbines under High-Load Conditions
by Haobo Wang, Daqing Zhou, An Yu and Junxun Guo
Processes 2024, 12(1), 72; https://doi.org/10.3390/pr12010072 - 28 Dec 2023
Viewed by 618
Abstract
Hydraulic vibrations in Francis turbines caused by cavitation profoundly impact the overall hydraulic performance and operational stability. Therefore, to investigate the influence of cavitation phenomena under high-load conditions, a three-dimensional unsteady numerical simulation is carried out for a Francis turbine with different head [...] Read more.
Hydraulic vibrations in Francis turbines caused by cavitation profoundly impact the overall hydraulic performance and operational stability. Therefore, to investigate the influence of cavitation phenomena under high-load conditions, a three-dimensional unsteady numerical simulation is carried out for a Francis turbine with different head operating conditions, which is combined with the SST k-w turbulence model and two-phase flow cavitation model to capture the evolution of cavitation under high-load conditions. Additionally, utilizing entropy production theory, the hydraulic losses of the Francis turbine during cavitation development are assessed. Contrary to the pressure-drop method, the entropy production theory can quantitatively reflect the characteristics of the local hydraulic loss distribution, with a calculated error coefficient τ not exceeding 2%. The specific findings include: the primary sources of energy loss inside the turbine are the airfoil cavitation and cavitation vortex rope, constituting 26% and 71% of the total hydraulic losses, respectively. According to the comparison with model tests, the vapor volume fraction (VVF) inside the draft tube fluctuates periodically under high-load conditions, causing low-frequency pressure pulsation in the turbine’s power, flow rate, and other external characteristic parameters at 0.37 Hz, and the runner radial force fluctuates at a frequency of 1.85 Hz. Full article
(This article belongs to the Special Issue State-of-the-Art Energy Conversion and Storage)
Show Figures

Figure 1

13 pages, 6270 KiB  
Article
Research on the Hydraulic Excitation Characteristics of the Top Cover Caused by the Radial Installation Deviation of the Seal of a 1GW Francis Turbine
by Kun Jin, Yonggang Lu, Peng Lin, Zequan Zhang, Juan Li, Yun Zhao, Xingxing Huang and Zhengwei Wang
Processes 2023, 11(11), 3172; https://doi.org/10.3390/pr11113172 - 07 Nov 2023
Viewed by 599
Abstract
The radial installation deviation of the turbine runner will change the gap flow between the upper crown and the lower ring seal, which will affect the radial force of the runner and the hydraulic excitation characteristics of the top cover. This research focuses [...] Read more.
The radial installation deviation of the turbine runner will change the gap flow between the upper crown and the lower ring seal, which will affect the radial force of the runner and the hydraulic excitation characteristics of the top cover. This research focuses on the 1GW Francis turbine on the right bank of the Baihetan hydropower station. The pressure distribution along the circumference of the top cover was analyzed, and the effects of deviations on the specific generation of hydraulic excitation forces were studied. This research shows that the increase in radial deviation will slightly reduce the output and efficiency, and the radial force on the runner increases parabolically. When the radial deviation is 1.5 mm, the radial force is 5.9 times higher compared to the case without any deviation, and the radius of the fitting circle of the radial force behavior trajectory increases with the increase in radial deviation. In addition, the radial deviation has little effect on the internal flow of the runner and the pressure distribution in the upper crown chamber. The dominant frequency components at the upstream monitoring points include fn, 15 fn, 24 fn, and 30 fn. The dominant frequency components at the downstream monitoring points include the blade passing frequencies of 15 fn and 30 fn. However, with the increase in radial deviation, the fluctuation amplitudes exhibit an asymmetric distribution, the uniformity of the pressure distribution in the circumferential direction of the labyrinth seal area becomes significantly worse, and the waveform of the downstream monitoring points changes significantly and presents a non-uniform distribution in one rotation cycle. Full article
(This article belongs to the Special Issue State-of-the-Art Energy Conversion and Storage)
Show Figures

Figure 1

16 pages, 7187 KiB  
Article
Hydraulic Characterization of Variable-Speed Pump Turbine under Typical Pumping Modes
by Linmin Shang, Jingwei Cao, Zhengwei Wang and Xiaobing Liu
Processes 2023, 11(10), 2903; https://doi.org/10.3390/pr11102903 - 02 Oct 2023
Cited by 1 | Viewed by 894
Abstract
The pump turbine is a crucial component of pumped storage hydropower plants. When operated at a constant speed, it does not respond well to variations in the grid frequency. To improve the hydraulic efficiency of pumped storage units, variable-speed units have been introduced. [...] Read more.
The pump turbine is a crucial component of pumped storage hydropower plants. When operated at a constant speed, it does not respond well to variations in the grid frequency. To improve the hydraulic efficiency of pumped storage units, variable-speed units have been introduced. However, the mechanism of variable-speed pump turbines has not been extensively studied numerically. In this study, the flow characteristics of a variable-speed pump turbine were computed under two typical pumping modes, the maximum head and minimum flow rate condition, as well as the minimum head and maximum flow rate condition. The computed results aligned with experimental results, and the changing trends of hydraulic thrust under these two pumping modes were discussed. The error for the Hmax, Qmin condition was 1.3%, and the error for the Hmin, Qmax condition was −1.9%. These error values fell within a reasonable range. The research findings indicate that in the Hmax, Qmin condition, the flow within the flow passage exhibited higher velocity, which was 84.87 m/s, increased flow turbulence, larger pressure fluctuations, and poorer unit stability. On the other hand, in the Hmin, Qmax condition, both the axial hydraulic thrust and radial forces were greater, and there were sudden changes in the extreme values of pressure fluctuations over a certain period of time. It is recommended to avoid operating the variable-speed pump turbine under these two conditions during pumping operations. Full article
(This article belongs to the Special Issue State-of-the-Art Energy Conversion and Storage)
Show Figures

Figure 1

12 pages, 7990 KiB  
Article
Numerical Prediction of Erosion of Francis Turbine in Sediment-Laden Flow under Different Heads
by Jinliang Wang, Xijie Song, Hu Wang, Ran Tao and Zhengwei Wang
Processes 2023, 11(9), 2523; https://doi.org/10.3390/pr11092523 - 23 Aug 2023
Cited by 1 | Viewed by 757
Abstract
Hydropower stations are an important source of clean energy, usually operating in sandy water flow, and the turbine wheels may suffer severe wear and tear. In addition, during the operation of the unit, it is necessary to operate at different water heads according [...] Read more.
Hydropower stations are an important source of clean energy, usually operating in sandy water flow, and the turbine wheels may suffer severe wear and tear. In addition, during the operation of the unit, it is necessary to operate at different water heads according to the actual situation, which will result in varying degrees of wear and tear. In this paper, the Lagrange method is used to study the wear characteristics of a Francis turbine under different water heads. The research object is the water turbine in Wanjiazhai Hydropower Station. Research has shown that wear on the walls of the turbine volute, guide vanes, and runner is inevitable, and the clearance walls are also vulnerable to wear. The difference in the water head mainly affects the movement trajectory and impact speed of particles. The higher the water head, the more severe the wear on the wall surface of the flow passage components. Both the crown and lower ring of the runner are worn. The impact of particles causes wear at this location, and the greater the relative velocity relative to the runner, the more severe the wall wear. This indicates that reasonable head operating conditions can effectively reduce wall wear, which provides guidance for the operation of hydraulic turbines. Full article
(This article belongs to the Special Issue State-of-the-Art Energy Conversion and Storage)
Show Figures

Figure 1

15 pages, 10251 KiB  
Article
Study on the Internal Flow Characteristics of Long and Short Blade Runners of a 1000 MW Francis Turbine under Different Opening Conditions
by Hao Chen, Yonggang Lu, Kui Liu, Zequan Zhang, Honghui Li, Xingxing Huang, Weiqiang Zhao and Zhengwei Wang
Processes 2023, 11(6), 1796; https://doi.org/10.3390/pr11061796 - 13 Jun 2023
Cited by 4 | Viewed by 821
Abstract
The 1000 MW Francis turbine unit at the Baihetan hydropower station is the maximum capacity unit in the world at present, and it has adopted the runner type with long and short blades. For this ultra-high output Francis turbine, especially with the breakthrough [...] Read more.
The 1000 MW Francis turbine unit at the Baihetan hydropower station is the maximum capacity unit in the world at present, and it has adopted the runner type with long and short blades. For this ultra-high output Francis turbine, especially with the breakthrough runner structure, the hydraulic excitation phenomenon caused by internal dynamic and static interference is the key factor for the stability of the unit. In this study, the 1000 MW Francis turbine unit is taken as the research object, and the rated output conditions with different guide vane openings are selected for comparative analysis. The flow field structure and the pressure pulsation characteristics inside the guide vane and runner under different openings are obtained. The distribution characteristics and evolution law of the vortex in the runner under different guide vane openings are analyzed. The results show that the dynamic and static interference between the runner and the guide vane induces the local high-speed flow to appear in the vaneless area, and the larger the guide vane opening, the smaller the dynamic and static interference between the runner and the guide vane; the vortex in the runner mainly develops and evolves from the inlet to the outlet and is mainly distributed near the blade wall surface. The pressure pulsation inside the runner is mainly due to the action of dynamic and static interference. The pressure pulsation induced by the dynamic and static interferences shows a decreasing law from the runner inlet to the runner outlet. Full article
(This article belongs to the Special Issue State-of-the-Art Energy Conversion and Storage)
Show Figures

Figure 1

14 pages, 7693 KiB  
Article
Research on Two-Way Contra-Rotating Axial-Flow Pump–Turbine with Various Blade Angles in Pump Mode
by Yiming Chen, Ce An, Rongyong Zhang, Qiang Fu and Rongsheng Zhu
Processes 2023, 11(5), 1552; https://doi.org/10.3390/pr11051552 - 18 May 2023
Cited by 3 | Viewed by 991
Abstract
In tidal two-way contra-rotating units, significant differences in performance often occur when arranging the front and rear impellers, which requires an optimized design of the impellers. To solve this problem, by reducing the blade inlet and outlet angles, the impact of different blade [...] Read more.
In tidal two-way contra-rotating units, significant differences in performance often occur when arranging the front and rear impellers, which requires an optimized design of the impellers. To solve this problem, by reducing the blade inlet and outlet angles, the impact of different blade angles on the performance of two-way pump–turbines and the internal flow was explored, and the effects of the blade inlet angle of the impellers on the performance of the counter-rotating pump were obtained. Afterward, the streamline and vorticity of the two-stage impeller at different angles were analyzed. The results show that different blade angles will have a certain impact on the internal flow of the two-way pump–turbine. Different blade outlet angles have a significant impact. The variation in different inlet blade angles is not significant for the vorticity changes in the front impeller and rear impeller. In addition, changes in the outlet blade angle will have an impact on the location of LE impact water of the rear impeller, which in turn affects the contours of vorticity of the rear impeller near LE, which also means that the vorticity in this area is mainly dominated by the vortex stretching term. Full article
(This article belongs to the Special Issue State-of-the-Art Energy Conversion and Storage)
Show Figures

Figure 1

Review

Jump to: Research

16 pages, 859 KiB  
Review
Current, Projected Performance and Costs of Thermal Energy Storage
by Laura Pompei, Fabio Nardecchia and Adio Miliozzi
Processes 2023, 11(3), 729; https://doi.org/10.3390/pr11030729 - 28 Feb 2023
Cited by 7 | Viewed by 2964
Abstract
The technology for storing thermal energy as sensible heat, latent heat, or thermochemical energy has greatly evolved in recent years, and it is expected to grow up to about 10.1 billion US dollars by 2027. A thermal energy storage (TES) system can significantly [...] Read more.
The technology for storing thermal energy as sensible heat, latent heat, or thermochemical energy has greatly evolved in recent years, and it is expected to grow up to about 10.1 billion US dollars by 2027. A thermal energy storage (TES) system can significantly improve industrial energy efficiency and eliminate the need for additional energy supply in commercial and residential applications. This study is a first-of-its-kind specific review of the current projected performance and costs of thermal energy storage. This paper presents an overview of the main typologies of sensible heat (SH-TES), latent heat (LH-TES), and thermochemical energy (TCS) as well as their application in European countries. With regard to future challenges, the installation of TES systems in buildings is being implemented at a rate of 5%; cogeneration application with TES is attested to 10.2%; TES installation in the industry sector accounts for 5% of the final energy consumption. From the market perspective, the share of TES is expected to be dominated by SH-TES technologies due to their residential and industrial applications. With regard to the cost, the SH-TES system is typically more affordable than the LH-TES system or the TCS system because it consists of a simple tank containing the medium and the charging/discharging equipment. Full article
(This article belongs to the Special Issue State-of-the-Art Energy Conversion and Storage)
Show Figures

Figure 1

Back to TopTop