Article

Energy Planning of Renewable Energy Sources in an Italian Context: Energy Forecasting Analysis of Photovoltaic Systems in the Residential Sector

by
Domenico Palladino
* and
Nicolandrea Calabrese
DUEE Department, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Via Anguillarese 301, Santa Maria di Galeria, 00123 Rome, Italy
*
Author to whom correspondence should be addressed.
Energies 2023, 16(7), 3042; https://doi.org/10.3390/en16073042
Submission received: 27 February 2023 / Revised: 23 March 2023 / Accepted: 25 March 2023 / Published: 27 March 2023

Abstract

:
Solar photovoltaic systems will play a key role in the country’s energy mix thanks to their ability to meet increasing energy needs while reducing greenhouse gas emissions. Despite the potential of solar photovoltaic energy, several criticalities remain, such as the intermittent nature and the need for significant land use for its implementation. In this regard, this work aimed at evaluating the photovoltaic potentiality in a national context by 2030 and 2050, considering only installations on the roof surfaces of existing buildings, i.e., without consuming additional land. This study has allowed the answering of three key points: (i) the roof surface could represent a valuable and alternative solution for new installations, since it could amount to around 450 km2, (ii) the national target cannot be reached by only using installations on existing buildings, although some regions could get close to the target by 2050, and (iii) long-term energy incentives should be implemented branching out to each national region, considering their photovoltaic potential. Finally, a regional potential index was also defined, capable of evaluating the photovoltaic potential in each region, helping policymakers to adopt the most suitable energy strategies.

1. Introduction

The current geopolitical situation has highlighted multiple issues in the energy strategies of many countries looking for alternative energy sources to fossil fuels. In addition, the new European targets of achieving net-zero emissions by 2050 and the decoupling of national growth from the use of resources have led to a breakthrough in the green transition of the European Union to reduce net emissions by 2030 compared to 1990 levels [1]. Among the actions undertaken to achieve these objectives is the promotion of the use of renewable energy sources and the energy efficiency of buildings, which remains one of the main sectors accountable for total energy consumption.
In Italy, residential buildings are still accountable for 12% of total emissions [2], corresponding to about 30% of total energy requirements [3], mainly due to heating energy services, and mostly due to poor building envelope performance. In recent years, multiple energy efficiency actions have been implemented, ranging from the renovation of the whole national building stock, such as the Superbonus scheme [4], to raising awareness of the use of high-energy class equipment. However, this sector, which includes more than 12 million buildings across the country [5], is one of the most energy-intensive sectors, with an electricity consumption of over 65,500 GWh on average in the last years [6,7,8,9,10,11,12,13]. Among the possible strategies to cover this energy need could be the massive use of photovoltaic systems, since over 1100 kWh per kW of installed power could be produced on average across the country [14,15,16,17,18,19].
Solar photovoltaic energy could be crucial both in Europe and Italy due to its potential of meeting increasing energy needs while reducing greenhouse gas emissions. According to a study carried out by the International Energy Agency (IEA), Italy set an ambitious target of 52 GW of photovoltaic capacity by 2030, i.e., around 2.5 times the value recorded in 2020, indicating photovoltaic systems as a key player in the country’s energy mix [20].
In the literature, photovoltaics is widely studied, both in terms of technology development and forecasting model implementation. Only in the last year, a large number of studies were carried out with different purposes, such as performing energy and exergy balances of photovoltaic systems [21,22,23,24,25], the analysis of new materials or photovoltaic technologies [26,27], forecasting analysis to check its potentiality over the years [28,29,30,31] by also using machine learning [32,33,34] or other specific methods [35,36,37], or to analyze national energy policy [38,39].
Despite the potential and convenience of solar photovoltaic energy, as highlighted in these works, there are several criticalities: the intermittent nature of solar energy, the need for significant land use for its implementation, high levels of bureaucracy, and the regulatory uncertainties that have hindered the growth of the sector. As an energy policy, solar photovoltaic energy could have significant potential to become one of the major sources of electricity. Nevertheless, there are relevant challenges that need to be addressed, particularly concerning land use.
To increase the number of photovoltaic installations, Italy has issued the new Law Decree n. 17 of 2022 [40] aiming at reducing the levels of bureaucracy and promoting new installations of photovoltaic systems on the roofs of existing buildings, including those falling in A-zones, i.e., the historical city centers.
As a result of this framework, this study aimed at evaluating the potentiality and energy production of photovoltaics in a national context. In particular, as photovoltaic systems will play a key role in the national energy mix, this study was performed to understand the real potential of photovoltaics by 2030–2050 when only installed on the roofs of existing buildings, i.e., without consuming additional land. The study aims to answer three key points in detail:
(1)
Is it possible to use only the roof surface of existing buildings for the new installations of photovoltaic panels?
(2)
What could be the productivity of the photovoltaic panels by 2050 and what could be the theoretical maximum power that could be placed on the roof surface of existing buildings?
(3)
Would it be possible to meet European targets by placing photovoltaic panels only on the roof surfaces of existing buildings?
To answer these key questions, a careful research procedure was adopted aimed at (i) evaluating the roof surface available for new installations of photovoltaic systems, (ii) understanding the current number of installations and productivity of the photovoltaic systems placed only in the residential sector, (iii) assessing the growth rates of photovoltaic panels in the residential sector, (iv) performing a forecast analysis, and (v) analyzing and comparing the theoretical photovoltaic energy production with respect to European targets.
The paper is structured as follows: the research procedure is detailed in Section 2, the underlying current energy consumption of the residential sector (Section 2.1), the state-of-the-art photovoltaic system (Section 2.2), and the theoretical roof surface of existing buildings (Section 2.3). As national reports provide disaggregated data only on an annual basis, a comparison of the energy production of photovoltaic panels on a monthly and annual basis was also performed to check the reliability of the annual forecasting analysis. This discussion is reported at the beginning of Section 3 (Section 3.1). Finally, the results of the forecasting analysis were discussed in Section 3.2, whilst the main findings are remarked upon in the conclusions.

2. Materials and Methods

The forecasting analysis was performed by planning a detailed research procedure (Figure 1) based on: (i) the energy consumption of the buildings sector, based on national reports provided by the National Electricity Network [6,7,8,9,10,11,12,13], (ii) the state-of-the-art photovoltaic panels placed only on the roofs of residential buildings, according to the annual reports provided by Energy Services Manager [14,15,16,17,18,19], and (iii) the type and number of building units as well as their roof surface area across the country, assessed from data provided by the National Institute of Statistics [5]. Data from the National Electricity Network and Energy Services Manager is provided for each Italian region; therefore, all of the analyses were carried out in regional detail. However, for clarity in the presentation, the aggregated results are discussed, distinguishing five Italian zones:
  • Northwest: including Valle d’Aosta, Piemonte, Liguria, and Lombardia regions;
  • Northeast: including Trentino, Friuli Venezia Giulia, Veneto, and Emilia Romagna;
  • Centre: grouping Toscana, Umbria, Marche, and Lazio;
  • South: grouping Abruzzo, Campania, Molise, Puglia, Basilicata, and Calabria;
  • Islands: including the two islands of Sicilia and Sardegna.
A key point of the work consists of the evaluation of the available roof surface area where photovoltaic panels could be placed; in fact, one of the purposes of the study is to check the possibility of using existing surfaces for this kind of application, i.e., without further land use. For this analysis, an estimation of the roof surface area of existing buildings starting with data provided by the National Institute of Statistics [5] was attempted.
Furthermore, for each region, the growth rates relating to the number and peak power of photovoltaic panels placed on existing buildings and the energy consumption of the building sector were also estimated. In addition, the improvements in photovoltaic panels over the year could also be taken into account, although the developments of this technology in the future are neither available nor foreseeable. For that reason, the following growth or development rates (GR or DR) were taken into account for the forecasting analysis based on data availability:
  • Growth rate of energy consumption (GREC): this was calculated considering the annual growth rates from 2014 (see Section 2.1);
  • Growth rate of photovoltaic panels (GRPhV): this was calculated considering the annual growth rates from 2016 (see Section 2.2);
  • Development rate of photovoltaic panels (DRP-PhV): this was calculated considering the annual development rates recorded from 2016 (see Section 2.2).
The mean annual values of energy consumption and the number of new installations of photovoltaic panels were also calculated and assumed as the reference values (data used from 2022) for the forecasting analysis by applying different GR values.
Finally, the forecasting analysis was performed for 2050 by checking: (i) the photovoltaic power installed by 2030 and 2050, (ii) the theoretical roof area needed for photovoltaic panels, and (iii) the energy need covered by photovoltaic panels. The forecasting analysis was performed with and without DRP-PhV to highlight the increase in energy production due to technology development.
Results were finally analyzed to evaluate the achievement of the national targets by 2030 and 2050 and to underline the potentiality and the issues of only installing photovoltaic systems on the roofs of existing buildings.

2.1. Energy Consumption of National Buildings Stock

The electrical energy consumption of the national building stock was assessed in agreement with national annual reports provided by the National Electricity Network [6,7,8,9,10,11,12,13]; in particular, the available data on an annual basis between 2014 and 2021 was taken into account (Table 1).
According to this data, a slight but significant variation (in relative terms) in electricity consumption can be highlighted; in fact, the energy consumption of the building sector has varied over the years by a value between −6.86% (Valle d’Aosta, 2019) and +7.22% (Veneto, 2015). Based on this trend, annual growth rates associated with energy consumption (GREC) were estimated for each region as the relative difference between two consecutive years. Starting from these values, a mean GREC was assessed and used to evaluate the variation in electrical energy consumption of the national building stock in the forecasting analysis. The mean GREC assessed from the data in Table 1 is reported in the next section (see Section 3.2).

2.2. Photovoltaic Systems: Growth and Development Rates and Energy Production

Based on the annual reports provided by Energy Services Manager [14,15,16,17,18,19], the state-of-the-art photovoltaic systems in the residential building sector were also detailed. In this case, disaggregated data were available only from 2016 and on an annual basis, although more information on photovoltaic systems is available from 2008. The number of photovoltaic panel installations on the roofs of the building stock and the total photovoltaic power produced every investigated year is detailed in Table 2 and Table 3, whilst the roof surface required for photovoltaic panels is reported in Table 4. It is worth noting that while the number of new photovoltaic panel installations and the photovoltaic power output are both provided by national reports, the roof surface area required by photovoltaic panels was assessed considering an average area per kW of 6.18 m2/kW. This average value was evaluated based on the surface generally required by polycrystalline panels (the most common solution as indicated in [14,15,16,17,18,19]) with nominal power of between 150 and 450 W, and increased by a precautionary factor of 1.25.
According to data from the national reports [14,15,16,17,18,19], it was worth noting that the highest number of installations can be found in the Northeast zone of Italy (around 15,780 photovoltaic installations overall) thanks to the highest number of new installations found in Lombardia in 2021. Although the Islands zone takes into account only two regions (Sardegna and Sicilia), it is worth noting that the number of installations is similar to the number for the South, as well as the photovoltaic power and roof surface area occupied by photovoltaic panels, highlighting the strong impact of this technology in these two regions.
Based on this data, some growth rates correlated to the number of new installations (GRPhV) were assessed (Table 5); in particular, four growth rates for each region were considered:
  • GRPhV-1: this was assessed as the mean value considering all of the available data from 2016 to 2021;
  • GRPhV-2: this was assessed as the mean value considering all of the available data by excluding the extreme values (i.e., the minimum and the maximum values in order to neglect the effect of the last national incentive (Superbonus), which led to a significant increase in the number of new installations in many regions);
  • GRPhV-3: this was assessed as the maximum value considering all of the available data but excluding the extreme values;
  • GRPhV-4: this was assessed as the minimum value considering all of the available data but excluding the extreme values.
Furthermore, based on data assessed or provided by national reports, the mean values in terms of photovoltaic power, the number of installations, energy production, and roof surface area required for each installation were finally assessed and assumed as reference values from 2022 (see Section 3) as this information is not yet available.
Finally, to take into account the improvements in photovoltaic technology over the years, a mean development rate was also estimated for each region. In particular, based on the number of new installations and the total power of photovoltaic systems installed every year, the average power for each installation was assessed and development rates of this technology (DRP-PhV) were evaluated as the relative difference between two consecutive years. Starting from these values, a mean DRP-PhV was assessed (Table 6).

2.3. National Building Stock: Roof Surface Area Calculation

One key point in the forecasting analysis lies in the roof surface area assessment, which used the roof surface area of existing buildings and is calculated using data provided by the National Institute of Statistics [5], which is available online. Considering the limited information and correlation provided by [5], such as the number of residential buildings per number of floors, the number of buildings per number of building units, and the number of building units per net surface range, the following steps were followed for the roof surface area calculations:
  • Step 1: a correlation between the number of buildings per number of floors (the National Institute of Statistics groups data into “one floor”, “two floors”, “three floors”, and “four and more floors”) and the number of buildings per building units (data grouped into “one unit”, “two units”, “three or four units”, “from five to eight units”, “from nine to fifteen units”, and “more than sixteen units”) was attempted;
  • Step 2: the total net surface area of building units was assessed by correlating data obtained from step 1 and the number of building units per specific net surface range provided by [5] (data groups into “≤29 m2”, “30–39 m2”, “40–49 m2”, “50–59 m2”, “60–79 m2”, “80–99 m2”, “100–119 m2”, “120–149 m2”, and “≥150 m2”);
  • Step 3: for the buildings falling into the group “four or more floors” provided by [5], an average and weighted height was assessed varying the number of the floors in the 4–14 range based on the number of building units;
  • Step 4: for each group of buildings (“one floor”, “two floors”, “three floors”, and “four and more floors”), the total net surface area was assessed and divided for the height of the buildings, calculating the theoretical roof surface area of existing buildings.
According to [5], it was possible to perform this analysis by considering around 12 million residential buildings, of which almost 50% are on “two floors”, around 24% on “three floors”, and just over 17% on “one floor”. Buildings with “four or more floors” represent the minority of the sample (just under 10%). Furthermore, the number of building units for each building is highly variable, with a clear difference for single-family units (SFH—around 54% of the sample) and multi-family houses (MFH). Finally, the data highlights that buildings with more than nine building units are a small percentage of the sample (less than 5% overall), indicating a lower diffusion of this type of building.
To proceed with step 1, the following assumptions were made:
  • buildings on “one floor” were considered buildings with only one building unit;
  • buildings on “two floors” were associated with buildings from one to four building units;
  • buildings on “three floors” were considered as buildings from two to eight building units;
  • buildings on “four or more floors” were associated with buildings with more than four building units.
Based on these assumptions, around 31 million building units were correlated and grouped into the ranges, as shown in Table 7: around 21% of the sample falls into “one floor” (SFH), about 25% fall into “two floors” (around 8.5 million of the sample), whilst more than 40% fall into buildings with “four or more floors”.
The evaluated distribution was merged with the distribution of the sample per specific surface area ranges provided by the National Institute of Statistics (step 2), and a theoretical net surface area of building units was assessed by considering an average value for each surface area range (step 3). An iteration analysis varying the number of floors for the buildings falling into the “four or more floors” group was carried out, calculating an average and weighted number of floors for this type of building equal to 5.48 m (step 4). A total roof surface area was assessed to be around 1350 km2; finally, since no information regarding the inclination of the roofs is provided, an average pitch inclination of 25° was assumed, obtaining a total roof surface area of about 1490 km2, which is considered as the roof surface area value for existing buildings. It is worth noting that the theoretical roof surface area can be considered a precautionary value as it was estimated starting from the net surface area of building units. Therefore, it could be possible that the actual surface area could also be higher than the estimated value. Furthermore, assuming that not all of the roofs have an optimal orientation for the installation of photovoltaic panels, the calculated roof surface area values have been further reduced. In this regard, it was assumed that only 30% of the surface area has suitable conditions for the installation of photovoltaic systems, reducing the available surface area to around 447 km2 overall.
The percentage distribution of the sample from steps 2 and 3 for each surface area range is shown in Table 8, whilst the maximum theoretical roof surface areas and the reference roof surface areas adopted for the forecasting analysis are detailed in Table 9. More detailed information in Table A1, Table A2 and Table A3 is reported in Appendix A.

3. Results and Discussion

3.1. Photovoltaic Energy Production: Annual vs. Monthly Calculations

As stated, all of the national reports on photovoltaic systems [14,15,16,17,18,19] provided disaggregated data only on an annual basis, whilst aggregate data (i.e., including all of the sectors) is also provided monthly. The electrical energy consumption is only provided on an annual basis [6,7,8,9,10,11,12,13] for each sector. As the impact of the photovoltaic system on the residential sector was studied in this work, it was only possible to take into account disaggregated data on an annual basis. However, the energy production of photovoltaic systems, as well as the energy requirements of the residential sector, are strongly dependent on the month of the year and location. For that reason, a preliminary analysis was performed aimed at checking the reliability of the annual forecasting concerning monthly forecasting because of the unavailability of some monthly data. This analysis was only possible for photovoltaic energy production since this monthly data can be obtained from the solar atlas provided by the Energy Services Manager [41].
For this preliminary analysis, the following assumptions were made:
  • The energy production per m2 of a photovoltaic system with monthly steps is assessed according to the solar atlas provided by the Energy Services Manager for each region and investigated year [41];
  • Since national reports [14,15,16,17,18,19] provide only the number of new installations with annual steps, it was equally shared by the days of each month. The same assumption was made for the installed power since national reports did not provide any information on a monthly step.
Based on these assumptions (the monthly energy production, the number of new installations, and the power of photovoltaic systems installed on the roof of buildings), it was possible to carry out a monthly forecasting analysis for each region up to 2050. It was performed with the same approach adopted for the annual analysis, i.e., considering monthly growth rates for the number of new installations. Annual results estimated adopting monthly steps were thus compared to that returned on the annual basis to check the reliability of the two approaches.
The energy production comparison assessed with an annual or monthly approach for each region and year is shown in Figure 2. The annual estimated energy production starting from the monthly step is reported on the ordinate axis, whilst that on the annual basis is shown on the abscissa. It is worth noting that a little difference can be highlighted by adopting these two approaches; greater differences were found for the years 2017 and 2021, although this difference is around ±10% in the larger energy-producing regions.
This result can be affected by the assumptions made in this work; however, the lack of information on the number of new installations every month meant that it was not possible to perform a more accurate analysis. Nevertheless, although the outcomes on an annual basis are slightly lower than those on a monthly basis, they can be considered reliable and precautionary. It means that it is possible that the energy production of the photovoltaic systems could be even greater than the estimated values. According to this result, the forecasting analysis on an annual basis can be considered a cautionary scenario.

3.2. Photovoltaic Energy Forecasting

As already stated in previous sections, the forecasting analysis started in 2022 assuming the number of new installations of photovoltaic panels to be equal to the mean value found in the previous investigated years, as well as the photovoltaic power and energy production. Similarly, a mean value of energy consumption was also adopted. Based on these average values, using values from 2022 as the reference values, as detailed in Table 10, specific annual growth rates associated with the energy consumption of the residential sector (GREC) were applied to calculate the outgoing energy consumption in addition to the annual growth rates of the number of new installations of photovoltaic panels (GRPhV), as already described in Table 8.
The results for estimated photovoltaic systems power output by 2050 are shown in Figure 3 whilst Figure 4 displays the results relating to the theoretical optimal roof surface area required by the photovoltaic systems by 2050. The results give an interesting insight, highlighting the greatest impact of photovoltaic panels in specific zones of Italy. From all of the adopted scenarios, the most promising zone could be the Northeast zone of Italy mainly due to the important contribution provided by the Veneto (which affects the photovoltaic power by about 59%) and Emilia Romagna regions (which affects the photovoltaic power by about 29%). In this zone, the most probable scenario (GRPhV-2) could potentially recognize more than 9 GW of photovoltaic power by 2050, requiring a little less than 70% of the available roof surface of this zones. Even in the most conservative scenario (GRPhV-4) it could be possible to reach 7 GW of photovoltaic power output by 2050, confirming that this zone is the most promisingly productive areas in Italy. In the most promising scenario (GRPhV-3), 11 GW of photovoltaic power output by 2050 could potentially be achieved; however, it could require almost 80% of the available roof surface area. Moreover, this scenario is closely linked to the use of specific incentive systems such as the Superbonus, making it one of the more improbable scenarios.
The greatest potential can be highlighted in the Northwest and in the South zones, where less than 30–40% of the available roof surface could be used. In these zones, a photovoltaic power output of 7.0 GW (both Northwest and South) could potentially be achieved in the most promising scenario (GRPhV-3), although values of 5.5 GW (Northwest) and 4.0 GW (South) seem to be most probable (GRPhV-2), corresponding to less than 30% of the available roof surface area in those zones.
Similarly, the Centre zone showed significant room for flexibility since around 60–70% of the roof surface area would remain available. On the other hand, the Islands zone showed the least potential photovoltaic power output by 2050 due to the limited use of roof surfaces.
All of these scenarios confirmed a less marked growth for the central and southern regions of Italy, highlighting the need for specific incentive systems in those zones if more than the 5 GW threshold is to be exceeded by 2050.
It is worth noting that all of these scenarios could be feasible and technically possible since they could require less roof surface area than that estimated. Only for the Northeast area, the analyzed scenarios may not be feasible if greater incentives were adopted due to the smaller roof surface area available in that zone. According to these results, overall, it could be possible to reach around 6 GW of photovoltaic power output by 2030 if the moderate scenarios were considered (GRPhV-1 and GRPhV-2), i.e., 11.5% of the national goal, or a little bit more than 6.5 GW in the most promising scenario (GRPhV-3 corresponding to about 12.7% of the national goal). In the most conservative scenario (GRPhV-4), it could be possible to reach around 5.5 GW of photovoltaic power by 2030 overall, corresponding to about 10.5% of the national goal. The evaluated trends confirm the need for specific national incentives to increase the number of photovoltaic installations by 2030.
The energy produced and supplied by photovoltaic systems, with the respect to the electrical energy consumption of the building stock, was thus analyzed; the comparison is shown in Figure 5, Figure 6, Figure 7, Figure 8 and Figure 9 for each considered zone (disaggregated data are reported in Appendix A). The energy required for the residential sector was assessed over the year by adopting the estimated mean GREC, as reported in Table 10.
Relevant findings can be highlighted in these figures:
  • Northwest zone: the energy supplied by photovoltaic panels could potentially exceed 5500 GWh in all of the GRPhV scenarios, allowing 40% to 50% of the electrical energy requirements by the building stock to be met, depending on the growth rate. It is worth noting that the blue lines in Figure 5, Figure 6, Figure 7, Figure 8 and Figure 9 (representing the electrical energy to be covered by other energy sources) always have a downward concavity, indicating the good impact of these technologies already in this zone;
  • Northeast zone: the energy supplied by photovoltaic panels could potentially reach 7100 GWh even with low growth rates (GRPhV-4), covering more than 50% of the predicted electrical energy requirements of the building stock by 2050 (the red line crosses the blue line). Moreover, in the most promising scenario (GRPhV-3), the energy produced by photovoltaic panels could potentially reach more than 10,000 GWh, meeting more than 74% of electrical energy requirements;
  • Centre zone: although a smaller growth than in the northern area of Italy, it could be possible to meet 27–39% of the electrical energy requirements of the building stock by 2050. In that case, the most probable scenarios (GRPhV-1 and GRPhV-2) showed an energy coverage of 30–32% by achieving a potential energy production of around 3700–4000 GWh. However, these results pointed out that it could be necessary to take specific energy actions to reach the 50% threshold;
  • South zone: a completely different trend can be observed in this zone, which could underline possible issues of these regions to achieve the national target by 2050, where Puglia and Campania alone could produce more than 65% of the whole photovoltaic energy production. Nevertheless, the energy production would not exceed 6200 GWh, even in the most optimistic scenario (GRPhV-3), which would allow the meeting of 38% of the predicted electrical energy requirements of the building stock. The evaluated trends highlighted significant issues for all of these regions mainly due to the limited number of installations recorded to date. In this case, it could also be necessary to implement additional actions to reach the 50% threshold;
  • Islands: similar to the South zone, the results have also underlined how far away the target is for the Islands zone, even if the Sicilia region alone could produce more than 1200–1500 GWh on average. The produced energy in that zone could allow between 13% (GRPhV-4) and 28% (GRPhV-3) of electrical energy requirements to be met, with an average and most probable outcome of 19–20%; therefore, additional specific energy actions should also be considered to reach the 50% threshold in this area.
As stated, all of the scenarios are potentially feasible since the required roof surface area would always be less than the estimated value (equal to around 450 km2 overall). In fact, only in the Northeast area of Italy, could almost 80% of the roof surface be required, whilst, in all of the other zones, relevant room for improvement can be highlighted. In particular, when considering the produced energy and the available roof surface area, the northwestern area seems to be the area with the greatest power output potential, an area already widely distributed with this technology.
Furthermore, it is pertinent to underscore that, theoretically, the installable power on the roof surface areas (the estimated roof surface area could be around 450 km2) could exceed 72 GW, enabling the production of over 79,000 GWh of energy. When compared to national objectives, namely a 55% reduction in emissions and the installation of 52 GW of new photovoltaic capacity by 2030, these objectives may potentially be achievable solely through the utilization of existing building roof surface areas, without the need for additional land use. However, the analyses have revealed the necessity of a region-specific incentive system tailored to the real potential, in terms of available surface area.
In addition to this cautionary scenario, a further analysis was performed in which the development rate of photovoltaic technology was also taken into account. For this analysis, the mean DRP-PhV defined in Table 6 was considered for each region. A comparison between the two forecasting analyses (with and without considering DRP-PhV) was, therefore, carried out. The results shown in Table 11 are for two representative years (2030 and 2050) and the average scenario (GWPhV-2), highlighting that further development of this technology could help to reach a higher energy production by 2050 (around 26,000 GWh), i.e., increasing potential energy production by around 6% overall.
Nevertheless, since the developments of this technology in the future are neither available nor foreseeable, the forecasting analysis carried out without DRP-PhV can be considered a more conservative scenario.
In this light, a new index has been introduced, namely the regional potential index (RPI), defined as the ratio between the photovoltaic power installed by three chosen reference years (2021, 2030, and 2050) and the theoretical maximum that could be installed on the calculated optimal roof surface area (around 450 km2). For this analysis, the photovoltaic forecasting results with GRPhV-2 were considered since it is the average trend in many national regions.
The results of the RPI assessment are reported in Figure 10, where the blue, red, and green lines are the assessed RPI for each region by 2021 (actual situation), 2030, and 2050. It is worth noting that the closer the RPI gets to 0%, the greater the photovoltaic potential of the region, i.e., much of the calculated roof surface area could still be available for new installations.
The figure shows that the RPI could potentially be lower than 40% by 2050 in all of the southern regions, reflecting their great potential to realize new installations also in the following years. Many northern and central regions have an RPI closer to or greater than 40%; in particular, the Veneto region reaches an RPI in the order of 90%, indicating the possible saturation of the roof surface area a few years after 2050. It is worth noting that although the different potential of the regions, in terms of the available roof surface area, all of the northern and central regions have shown a similar trend in RPI, indicating similar actions in using and placing photovoltaic panels based on their energy requirements and potential. On the other hand, the South and Islands regions have shown a greater potential from 2050 (RPI lower than 30–40%), highlighting a currently lower photovoltaic diffusion in these zones. Furthermore, a greater gap between the 2030 and 2050 lines can also be observed but only in a few regions (such as Veneto and Marche); this trend could indicate that in those regions, the growth rate of new photovoltaic installations could be more marked (tending more towards an exponential rather than linear trend). On the other hand, in all other regions, the smaller differences between these two lines could indicate a greater need to adopt appropriate incentive actions to increase the number of new installations.
It is worth noting that none of the analyses took into account the effects of climatic change. As already known, climatic change can significantly affect the productivity of photovoltaic panels; however, it is difficult to understand or forecast these effects due to various environmental factors. For instance, increased temperatures and extreme weather events, such as droughts, floods, and storms, could reduce photovoltaic efficiency. Dust and air pollution on the surface of solar panels can reduce their ability to absorb sunlight and convert it into electricity. Furthermore, changes in cloud cover and atmospheric conditions can impact the amount and intensity of sunlight that reaches the panels, resulting in a decrease in their overall productivity. All of these factors can have a significant impact on the productivity of photovoltaic panels and should be considered when evaluating the potential effects of climate change on renewable energy production.
According to this premise, climate change can negatively influence the assessed producibility of photovoltaic panels through various environmental factors; however, many of these influences are still being researched, and it was not possible to forecast or include the real influence of climate change on our analysis. The study of its effects on the producibility of photovoltaic panels could be investigated in a medium-to-long-term study.

4. Conclusions

The International Energy Agency (IEA) has indicated solar photovoltaic systems as a key player in the country’s energy mix. Italy has set a target of achieving 52 GW of photovoltaic capacity by 2030, which is two and a half times the capacity recorded in 2020. Therefore, solar photovoltaic energy could be crucial for meeting increasing energy needs while reducing greenhouse gas emissions, both in Europe and Italy. Despite the potential and convenience of solar photovoltaic energy, there are several challenges associated with solar photovoltaic energy, such as the intermittent nature of the source, the significant land use required for its implementation, and the high levels of bureaucracy and regulatory uncertainties. Nevertheless, photovoltaic systems play a key role in national energy policies, with new decrees being issued to reduce the bureaucracy and promote new installations of photovoltaic systems on the roofs of existing buildings.
In this framework, this study aims to evaluate the photovoltaic potential and energy production in the national context, without consuming additional land, by focusing only on the roof surface area of existing buildings. The study aims to answer three key points (KP) to assess the potential and critical issues associated with the implementation of national policies.
The study found that the roof surfaces of existing buildings offer a potential area of around 450 km2, with considerable growth potential in several regions across Italy (KP1). Theoretically, the installable power on the roof surfaces could exceed 72 GW, enabling the production of over 79,000 GWh of energy (KP2). When compared to national objectives, namely the installation of 52 GW of new photovoltaic capacity by 2030, these objectives may potentially be achievable solely through the utilization of the roof surfaces of existing buildings, without the need for additional land use (KP3). However, the most probable scenarios have shown that it could be possible to reach only around 6 GW of photovoltaic power by 2030 overall, i.e., 11.5% of the national goal (KP2), indicating the need for a region-specific incentive system tailored to the real potential of each national zone (in terms of available surface area).
Moreover, the energy production in the moderate scenarios could only meet around 10% of the electricity needs of residential buildings, with an estimated production of around 6200 GWh at the national level (KP2-KP3). By 2050, photovoltaic production could potentially cover more than 38% of the energy needs but would still fall short of national and European targets. In the most promising scenarios, it could be possible to cover almost 50% of the electricity consumption by 2050 with long-term energy incentives (KP2-KP3). The use of the roof surface of existing buildings can help to reduce the land use required for this type of application; however, it is not enough to achieve the ambitious energy targets by 2030. Nevertheless, some regions of Italy, such as Veneto, Emilia Romagna, and Lombardia, could come close to meeting national targets but only by 2050, even in a moderate scenario, indicating the need to develop different forms of energy incentives in the national context. Although this study has considered the more conservative scenarios, it did not take into account the effects of climatic change, which can negatively influence the assessed energy production of photovoltaic panels due to various environmental factors. To evaluate the influence of climatic change on the present forecasting analysis a medium-to-long-term study should be carried out.
Finally, based on these results, a new index, namely the regional potential index, was also defined as the ratio between the photovoltaic power installed and the theoretical maximum that could be installed based on the calculated optimal roof surface areas. This index can be used to evaluate the photovoltaic potential for each region and it could be useful as support for the development of specific incentives based on the real availability of roof surface areas of the regions.

Author Contributions

Conceptualization, D.P.; methodology, D.P.; software, D.P.; validation, D.P.; formal analysis, D.P.; investigation, D.P.; resources, D.P. and N.C; data curation, D.P.; writing—original draft preparation, D.P.; writing—review and editing, D.P.; visualization, D.P.; supervision, D.P. and N.C. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

Data elaboration is from a new design analysis carried out consistently within the aim of this study.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviation

BUBuilding units
CCentre
DEDifference between energy consumption and energy produced by photovoltaic panels
DRDevelopment rate
ECEnergy consumption
GRGrowth rate
IIslands
KPKey point
MFHMulti-family house
NENortheast
NWNorthwest
PPower
PhVPhotovoltaics
RPIRegional potential index
SSouth
SFHSingle-family house

Appendix A

Table A1. Building distribution (absolute values): breakdown by geographical area of Italy, number of building floors, and building type (single-family house—SFH and multi-family house—MFH).
Table A1. Building distribution (absolute values): breakdown by geographical area of Italy, number of building floors, and building type (single-family house—SFH and multi-family house—MFH).
ZonesSFHMFH
1 Floor2 Floors3 Floors≥4 Floors
n. 1n. 1n. 2n. 3–4n. 2n. 3–4n. 5–8n. 3–4n. 5–8n. 9–15n. ≥16
Piemonte2,083,3894,458,3571,232,233290,6661,506,062407,623646,827728,39071,870324,261219,559
Valle d’Aosta82,127475,44351,2095690147,40524,36139,77655,212442025,04521,953
Liguria313515,4520011,4002050267051252971056701
Lombardia29,96386,31925,020278034,33610,09719,19322,462213313,69814,919
Trentino Alto Adige135,547519,959170,355118,771208,21161,571106,53335,15613,04757,98444,248
Veneto10,89365,2810047,781928817,10923,219190156173110
Friuli Venezia Giulia93,862478,762118,52569,672144,86332,77547,21012,26512,83223,70510,824
Emilia Romagna35,916156,7120057,459624012,54915,600139483934217
Toscana60,500310,99893,82128,403114,67133,06960,39854,270671130,29515,597
Umbria79,859279,14579,12742,30996,71129,11148,43830,468538221,31311,218
Marche15,81786,71716,748186137,4307007870815,65696836611946
Lazio21,253122,22821,674240863,50712,72520,47629,404227588013501
Abruzzo153,357220,70981,74963,11599,91631,84441,62816,49619,24233,93327,743
Molise44,813153,65816,368181960,13911,10215,24225,937169467163775
Campania13,35148,9130017,6932383280659573121412977
Puglia159,125270,14297,53198,438119,20528,33526,714032,44422,88518,287
Basilicata427,892160,16976,91981,82094,01200039,41319,61213,488
Calabria39,30753,92214,972166419,9504978636410,78170724931133
Sicilia138,784217,66248,505538980,14719,15225,17742,491279795834677
Sardegna400,175477,25356,8426316226,96539,84948,53693,306539321,25113,485
Table A2. Building units distribution (absolute values): breakdown by geographical area of Italy, number of building floors, and building type (single-family house—SFH and multi-family house—MFH).
Table A2. Building units distribution (absolute values): breakdown by geographical area of Italy, number of building floors, and building type (single-family house—SFH and multi-family house—MFH).
ZonesSFHMFH
1 Floor2 Floors3 Floors≥4 Floors
n. 1n. 1n. 2n. 3–4n. 2n. 3–4n. 5–8n. 3–4n. 5–8n. 9–15n. ≥16
Piemonte82,127475,443102,41822,760294,81097,442238,658220,84626,518300,540526,872
Valle d’Aosta313515,4520022,800820016,02220,500178012,67216,824
Liguria29,96386,31950,04011,12068,67240,387115,16089,84912,796164,376358,056
Lombardia135,547519,959340,709475,085416,423246,283639,197140,62378,283695,8081,061,952
Trentino Alto Adige10,89365,2810095,56237,151102,65492,87711,40667,40474,640
Veneto93,862478,762237,049278,690289,727131,101283,25949,06276,993284,460259,776
Friuli Venezia Giulia35,916156,71200114,91824,96075,29262,4008366100,716101,208
Emilia Romagna60,500310,998187,643113,610229,341132,277362,389217,08140,265363,540374,328
Toscana79,859279,145158,254169,236193,422116,442290,628121,87032,292255,756269,232
Umbria15,81786,71733,496744474,86028,02752,24562,625580543,93246,704
Marche21,253122,22843,3489633127,01450,899122,855117,61613,651105,61284,024
Lazio153,357220,709163,499252,459199,832127,377249,76665,984115,454407,196665,832
Abruzzo44,813153,65832,7377275120,27744,40991,454103,74810,16280,59290,600
Molise13,35148,9130035,386953116,83723,829187116,94423,448
Campania159,125270,142195,062393,751238,410113,341160,2850194,663274,620438,888
Puglia427,892160,169153,838327,280188,024000236,478235,344323,712
Basilicata39,30753,92229,945665439,89919,91138,18343,123424329,91627,192
Calabria138,784217,66297,00921,558160,29576,608151,060169,96216,784114,996112,248
Sicilia400,175477,253113,68425,263453,930159,394291,217373,22332,357255,012323,640
Sardegna137,713216,53869,62215,472104,63641,69785,36988,771948581,69690,240
Table A3. Total net surface area distribution (absolute values in km2) of building units (BU): breakdown by geographical area of Italy (Northwest, Northeast, Centre, South, and Islands) and building type (single-family house—SFH and multi-family house—MFH).
Table A3. Total net surface area distribution (absolute values in km2) of building units (BU): breakdown by geographical area of Italy (Northwest, Northeast, Centre, South, and Islands) and building type (single-family house—SFH and multi-family house—MFH).
Building Type AreaNet Surface Distribution of the Building Units (km2)
≤2930–3940–4950–5960–7980–99100–119120–149≥150
SFHNorthwest0.000.221.152.8413.2521.7218.3317.4527.77
Northeast0.000.120.691.749.3618.2519.7920.4035.66
Centre0.000.150.761.909.6917.4116.5714.8421.76
South0.000.311.343.0415.8737.1638.9836.0947.29
Islands0.000.210.962.1410.6323.4828.7227.5933.67
MFH (2 floors)Northwest0.030.722.414.3115.6222.7016.6213.7418.71
Northeast0.010.180.681.265.509.048.367.7612.50
Centre0.010.310.961.746.759.187.085.527.30
South0.020.411.091.807.3513.7911.718.7810.05
Islands0.000.060.170.281.081.962.051.651.77
MFH (3 floors)Northwest0.030.902.995.3619.5127.8020.2916.8323.22
Northeast0.010.250.911.677.1511.4310.399.3314.56
Centre0.010.331.011.847.2710.228.036.268.22
South0.010.240.641.064.297.816.815.196.00
Islands0.010.240.681.094.237.718.106.326.66
MFH (≥4 floors)Northwest0.030.732.434.3615.9022.4616.3313.5218.69
Northeast0.010.170.601.114.717.456.675.919.10
Centre0.010.300.941.706.568.976.965.417.10
South0.010.260.681.134.638.717.525.766.62
Islands0.010.160.440.702.745.005.254.104.33
Table A4. Energy production obtained from forecasting analysis: scenario n. 1 (GRPhV-1).
Table A4. Energy production obtained from forecasting analysis: scenario n. 1 (GRPhV-1).
YearsNational Regions
1234567891011121314151617181920
20162109273878639912728115368104206821913119335118252170
20172311031435100446136321173801232411052215024439138294195
201822210314409745713831216474114232992014422936128281177
2019246113148499477140343178811242511072215724538140300194
2020237113450095519150344176811212691032216224138137304191
202124710365339255915235318276117262972016122735133291180
2022248113450599518148351182801242641052216124639140307193
20232631038578101573159374186781202641002016122835127275173
20242801140627105622167402198811272851072117224437133293181
20252991243681109675176431210841343081142118426039141313189
20263191247740113733185463223871423321212219627840148333198
20273401350803117795195498237911503581292320929742156355207
20283621453872122863206535252951583871372422331844164378216
20293861457947127936217574268981674171462523834046173403226
20304111561102913210162286172851021774501552625436348183430236
20314391666111713711032406633031061874861652727038850192458247
20324681771121314311972537123221111985241762828941453203488258
20334981876131714812992667653431152095661873030844355214520270
20345311981143015414092818213641202216111993132847358225554282
20355662087155316015292958823871252336592123235050660237590295
20366042193168616716603119484121302477112263437454063250629308
2037644221001831173180132810184381352617672403539857866263670322
2038686231071988180195434510944651402768282563642561769277714337
2039731241152159188212136311754941462918932723845366072292761352
2040779261232345195230138312625261523089642903948470575308811368
20418312713225462032497403135655915832610403084151675379324864384
20428862914227652112710424145659416434411223284355080582342921402
20439443015230022192941447156463117136412113494558786086360981420
2044100632163326022831924711680671178385130737246626919903791046439
2045107333175354023734634961805714185407141039648668982944001115459
20461144351883844246375852219397591924301522421507131050984211188480
204712193720141742564079550208380620045416424485276011221034441266502
204813003921645322664426579223785720848017724775581111991084671349524
204913854123149222774803610240391121650819125085786512811124921437548
205014774324853442885212642258296922553720635405992313691185191531573
1—Piemonte, 2—Valle d’Aosta, 3—Liguria, 4—Lombadia, 5—Trentino Alto Adige, 6—Veneto, 7—Friuli Venezia Giulia, 8—Emilia Romagna, 9—Toscana, 10—Umbria, 11—Marche, 12—Lazio, 13—Abruzzo, 14—Molise, 15—Campania, 16—Puglia, 17—Basilicata, 18—Calabria, 19—Sicilia, and 20—Sardegna.
Table A5. Energy production obtained from forecasting analysis: scenario n. 2 (GRPhV-2).
Table A5. Energy production obtained from forecasting analysis: scenario n. 2 (GRPhV-2).
YearsNational Regions
1234567891011121314151617181920
20162109273878639912728115368104206821913119335118252170
20172311031435100446136321173801232411052215024439138294195
201822210314409745713831216474114232992014422936128281177
2019246113148499477140343178811242511072215724538140300194
2020237113450095519150344176811212691032216224138137304191
202124710365339255915235318276117262972016122735133291180
2022249113450499517148351183811242641042216224339140305193
2023264113857610157116037618680120266982016322235128272173
20242831141625106618168404198841272871032017523537135288181
20253021244677111669178435211881343111092118824739143305189
20263231247735116724188469224931423361152220226140151324198
20273451350797121784198505239971503641212321627542159343207
202836914548641268482095432541021593931272423229144169363217
202939415589371329182215852701081684251342524930746178385227
2030421156210161389942336302881131784601412526732348189408237
20314501666110114410762466783061191894981492628734150199432248
20324811771119415011652597303261251995381572730836053211457259
20335141876129515712612747863471322115821652933038055223485271
20345491982140416413652898463691392236301743035540158236513284
20355872088152217114783059113931462366811833138042360249544297
20366272194165117916003229814181542507371933240844663263576311
2037670221011790187173234010564451622647972043343847166279610325
2038716241091941195187535911374731702808622153447049769295647340
2039766251172104204203037912245041792969332263650452472311685355
20408182612522822132197400131853618831310092383754155375329726372
20418742813424742232379422141957019833110912513858158379348769389
20429352914426832332575445152860720835111802644062361583368815407
20439993115529092432788470164564621937112762784166964986389863425
204410673316631552543018496177168723039313812934371868590412914445
204511413517834212653267524190673124241514933094577072394435969465
2046121936191370927735365532052778255439161532546826762994601026487
20471303382054022290382858422108282684651747343488878041034871087509
20481392412204361303414461623798812824921890361509518491085151152533
204914884323647293164486650256193829752120443805210218951135441220557
205015904525351283304857686275899831255122114015410959451185751292583
1—Piemonte, 2—Valle d’Aosta, 3—Liguria, 4—Lombadia, 5—Trentino Alto Adige, 6—Veneto, 7—Friuli Venezia Giulia, 8—Emilia Romagna, 9—Toscana, 10—Umbria, 11—Marche, 12—Lazio, 13—Abruzzo, 14—Molise, 15—Campania, 16—Puglia, 17—Basilicata, 18—Calabria, 19—Sicilia, and 20—Sardegna.
Table A6. Energy production obtained from forecasting analysis: scenario n. 3 (GRPhV-3).
Table A6. Energy production obtained from forecasting analysis: scenario n. 3 (GRPhV-3).
YearsNational Regions
1234567891011121314151617181920
20162109273878639912728115368104206821913119335118252170
20172311031435100446136321173801232411052215024439138294195
201822210314409745713831216474114232992014422936128281177
2019246113148499477140343178811242511072215724538140300194
2020237113450095519150344176811212691032216224138137304191
202124710365339255915235318276117262972016122735133291180
20222501134508100522149353184811252661082216325339141311195
20232671138586103582160379189811222681062016424037129283176
20242871141641109636170409203861302921152117726439137306186
20253091245700115696179443217911383171262219028941146330196
20263321348766121761190479233971473451372420531744155356207
202735714528381278322015172501031573751502522034847164385218
202838315569161349102135592681091674071642623738250175416230
2029412166110011419952256052871161784431792825541953186449243
20304431765109514910872386543081231894811952927445957197485256
20314761871119715711892527073301302015232133129550460210524270
20325111976130916513002667643541382145692333231855364223566285
20335502082143117414212828263791472286192543434260668237611301
20345912189156518315542988934071562436722783636866573252660317
20356352396171119316993159664361652597313033839672977267712335
2036682241041871203185833410444671762767953314042680082284769353
2037733261122046214203135311295011862948643624245887787302831373
2038788281212237226222137412205371983139393954449396293321898393
203984729131244623824283951319576210333102143147530105699341969415
20409103114126752512655418142661722335511104714957111581053621047437
20419783315229252642903442154266223737812065145261412701123851131462
204210513616531982783174468166771025140313125615566113931194091221487
204311303817834972933470495180376126642914266135771115291274351319514
204412144019238243093794524194981628345715506696176516771354621424542
204513054320741813254149554210787430048616857316482418391444911538572
204614034622445723434536587227893831951818327986788620171535221661603
2047150849242499936149606212463100533855219918717195422131635551794636
20481620522615466380542365726631078359588216595275102624281735891938671
204917415528259774015929695287911553816262353103979110426631846262093708
205018715930465354226483735311212394046662558113583118829211966662261747
1—Piemonte, 2—Valle d’Aosta, 3—Liguria, 4—Lombadia, 5—Trentino Alto Adige, 6—Veneto, 7—Friuli Venezia Giulia, 8—Emilia Romagna, 9—Toscana, 10—Umbria, 11—Marche, 12—Lazio, 13—Abruzzo, 14—Molise, 15—Campania, 16—Puglia, 17—Basilicata, 18—Calabria, 19—Sicilia, and 20—Sardegna.
Table A7. Energy production obtained from forecasting analysis: scenario n. 4 (GRPhV-4).
Table A7. Energy production obtained from forecasting analysis: scenario n. 4 (GRPhV-4).
YearsNational Regions
1234567891011121314151617181920
20162109273878639912728115368104206821913119335118252170
20172311031435100446136321173801232411052215024439138294195
201822210314409745713831216474114232992014422936128281177
2019246113148499477140343178811242511072215724538140300194
2020237113450095519150344176811212691032216224138137304191
202124710365339255915235318276117262972016122735133291180
2022246113450197513148349181791232621022116023838139302192
202325910375699856315836918375118261951915921434125267170
2024274114061410160616539519377124280982016822135131280176
20252901142661103652173421203791303001022017822936137294182
20263061245713106701182450214811363221052118923737143309189
20273241248768109754191480225831433461092120024538150324196
20283421351828112811200513237851503711132221125438157341203
20293621355893115872210548250871573971172322426239164357210
20303831458962118938220585264891654261212323727240172375218
2031405146210371211009231625278911734571252425128141180394226
2032428156611181241085242667293931814901302426629143188413234
2033453167112051281167254713309951905261342528130144197434242
2034479167512991311256266761325981995641392629831145206456251
20355061780140013513512798133431002096051442631532246216478260
20365351886150913814532938683611022196491492733433347226502269
20375661991162614215633079273811052306961552835434548236527279
20385991997175314616813229904011072417461602937435749247553289
2039633201041889149180833810574231102538001662939636951259581299
2040670211112036153194435511294461132658581723042038252271609310
2041708221182195158209137212054701152789211783144439653284640321
2042749231262366162225039012874951182919871843247040955297671333
20437922413425501662420409137452212130610591913349842356311705345
20448372514327481712602429146855012432011361973452743857325740357
20458862615229621752799450156757912733612182043555845359340777370
20469372716231931803011472167461013035213062123559146960356815383
20479902817334411853238495178764313337014012193662648662373856397
204810472918437091903483520190967813638815032273766350263390898412
204911083119739981953747545203871513940716122353870152065408943426
205011713221043092004030572217775314342617282433974353867427990442
1—Piemonte, 2—Valle d’Aosta, 3—Liguria, 4—Lombadia, 5—Trentino Alto Adige, 6—Veneto, 7—Friuli Venezia Giulia, 8—Emilia Romagna, 9—Toscana, 10—Umbria, 11—Marche, 12—Lazio, 13—Abruzzo, 14—Molise, 15—Campania, 16—Puglia, 17—Basilicata, 18—Calabria, 19—Sicilia, and 20—Sardegna.

References

  1. European Commission. Communication from the Commission to the European Parliament, the European Council, the Council, the European Economic and Social Committee and the Committee of the Regions. The European Green Deal. 2019. Available online: https://eur-lex.europa.eu/legal-content/IT/TXT/?uri=CELEX:52019DC0640 (accessed on 10 November 2022).
  2. Italian Institute for Environmental Protection and Research. Efficiency and Decarbonization Indicators of the National Energy System and the Electricity Sector. 2022. Available online: https://www.isprambiente.gov.it/files2022/pubblicazioni/rapporti/r363-2022.pdf (accessed on 10 November 2022). (In Italian)
  3. Ministry of Ecological Transition. Annual Report on the National Energy Situation. Data 2021. Available online: https://dgsaie.mise.gov.it/pub/sen/relazioni/relazione_annuale_situazione_energetica_nazionale_dati_2021.pdf (accessed on 10 November 2022). (In Italian)
  4. ENEA. Annual Report on Energy Efficiency over the Country. 2021. Available online: https://www.efficienzaenergetica.enea.it/component/jdownloads/?task=download.send&id=511&catid=40&Itemid=101 (accessed on 23 November 2022). (In Italian).
  5. National Institute of Statistics. National Census of the Population, Buildings, Energy Consumptions. 2011. Available online: http://dati.istat.it/ (accessed on 10 November 2022). (In Italian)
  6. National Electricity Network S.p.A. Report on Electric Energy Consumption in Italy: The Year 2014. Available online: https://download.terna.it/terna/0000/0642/35.pdf (accessed on 10 November 2022). (In Italian).
  7. National Electricity Network S.p.A. Report on Electric Energy Consumption in Italy: The Year 2015. Available online: https://download.terna.it/terna/0000/0837/41.pdf (accessed on 10 November 2022). (In Italian).
  8. National Electricity Network S.p.A. Report on Electric Energy Consumption in Italy: The Year 2016. Available online: https://download.terna.it/terna/0000/0964/23.pdf (accessed on 10 November 2022). (In Italian).
  9. National Electricity Network S.p.A. Report on Electric Energy Consumption in Italy: The Year 2017. Available online: https://download.terna.it/terna/0000/1089/69.pdf (accessed on 10 November 2022). (In Italian).
  10. National Electricity Network S.p.A. Report on Electric Energy Consumption in Italy: The Year 2018. Available online: https://download.terna.it/terna/6-CONSUMI_8d726f170b61362.pdf (accessed on 10 November 2022). (In Italian).
  11. National Electricity Network S.p.A. Report on Electric Energy Consumption in Italy: The Year 2019. Available online: https://download.terna.it/terna/6-CONSUMI_8d9cfa23d9b95aa.pdf (accessed on 10 November 2022). (In Italian).
  12. National Electricity Network S.p.A. Report on Electric Energy Consumption in Italy: The Year 2020. Available online: https://download.terna.it/terna/6-CONSUMI_8d9cecfdb0ebb54.pdf (accessed on 10 November 2022). (In Italian).
  13. National Electricity Network S.p.A. Report on Electric Energy Consumption in Italy: The Year 2021. Available online: https://download.terna.it/terna/6%20-%20CONSUMI_8dae443b9f610d6.pdf (accessed on 10 November 2022). (In Italian).
  14. Energy Services Manager. Statistical Report of the Solar Photovoltaic System: The Year 2016. Available online: https://www.gse.it/documenti_site/Documenti%20GSE/Rapporti%20statistici/Solare%20Fotovoltaico%20-%20Rapporto%20Statistico%202016.pdf (accessed on 10 November 2022). (In Italian).
  15. Energy Services Manager. Statistical Report of the Solar Photovoltaic System: The Year 2017. Available online: https://www.gse.it/documenti_site/Documenti%20GSE/Rapporti%20statistici/Solare%20Fotovoltaico%20-%20Rapporto%20Statistico%202017.pdf (accessed on 10 November 2022). (In Italian).
  16. Energy Services Manager. Statistical Report of the Solar Photovoltaic System: The Year 2018. Available online: https://www.gse.it/documenti_site/Documenti%20GSE/Rapporti%20statistici/Solare%20Fotovoltaico%20-%20Rapporto%20Statistico%202018.pdf (accessed on 10 November 2022). (In Italian).
  17. Energy Services Manager. Statistical Report of the Solar Photovoltaic System: The Year 2019. Available online: https://www.gse.it/documenti_site/Documenti%20GSE/Rapporti%20statistici/Solare%20Fotovoltaico%20-%20Rapporto%20Statistico%202019.pdf (accessed on 10 November 2022). (In Italian).
  18. Energy Services Manager. Statistical Report of the Solar Photovoltaic System: The Year 2020. Available online: https://www.gse.it/documenti_site/Documenti%20GSE/Rapporti%20statistici/Solare%20Fotovoltaico%20-%20Rapporto%20Statistico%20GSE%202020.pdf (accessed on 10 November 2022). (In Italian).
  19. Energy Services Manager. Statistical Report of the Solar Photovoltaic System: The Year 2021. Available online: www.gse.it/documenti_site/Documenti%20GSE/Rapporti%20statistici/Solare%20Fotovoltaico%20-%20Rapporto%20Statistico%202021.pdf (accessed on 10 November 2022). (In Italian).
  20. International Energy Agency. Renewables 2020. Analysis and Forecast to 2025. Available online: https://iea.blob.core.windows.net/assets/1a24f1fe-c971-4c25-964a-57d0f31eb97b/Renewables_2020-PDF.pdf (accessed on 23 November 2022).
  21. Kampik, M.; Fice, M.; Pilśniak, A.; Bodzek, K.; Piaskowy, A. An Analysis of Energy Consumption in Small- and Medium-Sized Buildings. Energies 2023, 16, 1536. [Google Scholar] [CrossRef]
  22. Lillo-Bravo, I.; Lopez-Roman, A.; Moreno-Tejera, S.; Delgado-Sanchez, J.M. Photovoltaic energy balance estimation based on the building integration level. Energy Build. 2023, 282, 112786. [Google Scholar] [CrossRef]
  23. G. Landera, Y.; C. Zevallos, O.; Neto, R.C.; Castro, J.F.D.C.; Neves, F.A.S. A Review of Grid Connection Requirements for Photovoltaic Power Plants. Energies 2023, 16, 2093. [Google Scholar] [CrossRef]
  24. Kuczynski, W.; Chliszcz, K. Energy and exergy analysis of photovoltaic panels in northern Poland. Renew. Sustain. Energy Rev. 2023, 174, 113138. [Google Scholar] [CrossRef]
  25. Yao, W.; Kong, X.; Xu, A.; Xu, P.; Wang, Y.; Gao, W. New models for the influence of rainwater on the performance of photovoltaic modules under different rainfall conditions. Renew. Sustain. Energy Rev. 2023, 173, 113119. [Google Scholar] [CrossRef]
  26. Jiao, J.; Yang, M.; Li, J.; Xiong, D.; Li, H. A novel high reflective glass-ceramic ink with Bi2Ti2O7 nanocrystals used for the photovoltaic glass backplane. J. Eur. Ceram. Soc. 2023; in press. [Google Scholar] [CrossRef]
  27. Chirwa, D.; Goyal, R.; Mulenga, E. Floating solar photovoltaic (FSPV) potential in Zambia: Case studies on six hydropower power plant reservoirs. Renew. Energy Focus 2023, 44, 344–356. [Google Scholar] [CrossRef]
  28. Mannino, G.; Tina, G.M.; Cacciato, M.; Merlo, L.; Cucuzza, A.V.; Bizzarri, F.; Canino, A. Photovoltaic Module Degradation Forecast Models for Onshore and Offshore Floating Systems. Energies 2023, 16, 2117. [Google Scholar] [CrossRef]
  29. Li, G.; Wei, X.; Yang, H. Decomposition integration and error correction method for photovoltaic power forecasting. Measurement 2023, 208, 112462. [Google Scholar] [CrossRef]
  30. Bezerra Menezes Leite, H.; Zareipour, H. Six Days Ahead Forecasting of Energy Production of Small Behind-the-Meter Solar Sites. Energies 2023, 16, 1533. [Google Scholar] [CrossRef]
  31. Dolara, A.; Leva, S.; Manzolini, G. Comparison of different physical models for PV power output prediction. Sol. Energy 2015, 119, 83–99. [Google Scholar] [CrossRef] [Green Version]
  32. Borunda, M.; Ramírez, A.; Garduno, R.; Ruíz, G.; Hernandez, S.; Jaramillo, O.A. Photovoltaic Power Generation Forecasting for Regional Assessment Using Machine Learning. Energies 2022, 15, 8895. [Google Scholar] [CrossRef]
  33. Mohamad Radzi, P.N.L.; Akhter, M.N.; Mekhilef, S.; Mohamed Shah, N. Review on the Application of Photovoltaic Forecasting Using Machine Learning for Very Short- to Long-Term Forecasting. Sustainability 2023, 15, 2942. [Google Scholar] [CrossRef]
  34. Cabezón, L.; Ruiz, L.G.B.; Criado-Ramón, D.; J. Gago, E.; Pegalajar, M.C. Photovoltaic Energy Production Forecasting through Machine Learning Methods: A Scottish Solar Farm Case Study. Energies 2022, 15, 8732. [Google Scholar] [CrossRef]
  35. Polo, J.; Martín-Chivelet, N.; Alonso-Abella, M.; Sanz-Saiz, C.; Cuenca, J.; de la Cruz, M. Exploring the PV Power Forecasting at Building Façades Using Gradient Boosting Methods. Energies 2023, 16, 1495. [Google Scholar] [CrossRef]
  36. Huang, Y.; Wu, Y. Short-Term Photovoltaic Power Forecasting Based on a Novel Autoformer Model. Symmetry 2023, 15, 238. [Google Scholar] [CrossRef]
  37. Lim, S.-C.; Huh, J.-H.; Hong, S.-H.; Park, C.-Y.; Kim, J.-C. Solar Power Forecasting Using CNN-LSTM Hybrid Model. Energies 2022, 15, 8233. [Google Scholar] [CrossRef]
  38. Woźniak, M.; Badora, A.; Kud, K.; Woźniak, L. Renewable Energy Sources as the Future of the Energy Sector and Climate in Poland—Truth or Myth in the Opinion of the Society. Energies 2022, 15, 45. [Google Scholar] [CrossRef]
  39. Hermoso, V.; Bota, G.; Brotons, L.; Morán-Ordóñez, A. Addressing the challenge of photovoltaic growth: Integrating multiple objectives towards sustainable green energy development. Land Use Policy 2023, 128, 106592. [Google Scholar] [CrossRef]
  40. President of Italian Republic. Law Decree 1st March 2022, n. 17. Urgent Measures to Contain the Electric Energy and Natural Gas Costs, for the Development of Renewable Energy Sources, and for Industrial Policies Relaunch. Available online: https://www.gazzettaufficiale.it/eli/gu/2022/03/01/50/sg/pdf (accessed on 10 November 2022). (In Italian).
  41. Energy Services Manager. Solar Atlas and Weather Forecast (sunRISE). Available online: http://sunrise.rse-web.it/ (accessed on 23 March 2023). (In Italian).
Figure 1. Research procedure adopted for performing photovoltaic forecasting.
Figure 1. Research procedure adopted for performing photovoltaic forecasting.
Energies 16 03042 g001
Figure 2. Comparison of the energy production of photovoltaic systems: annual vs. monthly calculation.
Figure 2. Comparison of the energy production of photovoltaic systems: annual vs. monthly calculation.
Energies 16 03042 g002
Figure 3. Power (MW) of photovoltaic panels: forecasting analysis over the years to 2050 for all of the national zones adopted in this study.
Figure 3. Power (MW) of photovoltaic panels: forecasting analysis over the years to 2050 for all of the national zones adopted in this study.
Energies 16 03042 g003
Figure 4. The theoretical roof surface area (%) required by photovoltaic panels: forecasting analysis over the years to 2050 for all of the national zones adopted in this study.
Figure 4. The theoretical roof surface area (%) required by photovoltaic panels: forecasting analysis over the years to 2050 for all of the national zones adopted in this study.
Energies 16 03042 g004
Figure 5. Energy requirements for the buildings sector, energy production, and energy requirements potentially met by photovoltaic panels by 2050 for various growth rates: the Northwest area of Italy.
Figure 5. Energy requirements for the buildings sector, energy production, and energy requirements potentially met by photovoltaic panels by 2050 for various growth rates: the Northwest area of Italy.
Energies 16 03042 g005
Figure 6. Energy requirements for the buildings sector, energy production, and energy requirements potentially met by photovoltaic panels by 2050 for various growth rates: the Northeast area of Italy.
Figure 6. Energy requirements for the buildings sector, energy production, and energy requirements potentially met by photovoltaic panels by 2050 for various growth rates: the Northeast area of Italy.
Energies 16 03042 g006
Figure 7. Energy requirements for the buildings sector, energy production, and energy requirements potentially met by photovoltaic panels by 2050 for various growth rates: the central area of Italy.
Figure 7. Energy requirements for the buildings sector, energy production, and energy requirements potentially met by photovoltaic panels by 2050 for various growth rates: the central area of Italy.
Energies 16 03042 g007
Figure 8. Energy requirements for the buildings sector, energy production, and energy requirements potentially met by photovoltaic panels by 2050 for various growth rates: the South area of Italy.
Figure 8. Energy requirements for the buildings sector, energy production, and energy requirements potentially met by photovoltaic panels by 2050 for various growth rates: the South area of Italy.
Energies 16 03042 g008
Figure 9. Energy requirements for the buildings sector, energy production, and energy requirements potentially met by photovoltaic panels by 2050 for various growth rates: the Islands of Italy.
Figure 9. Energy requirements for the buildings sector, energy production, and energy requirements potentially met by photovoltaic panels by 2050 for various growth rates: the Islands of Italy.
Energies 16 03042 g009
Figure 10. Regional Potential Index (RPI) calculated for each region and different years: 2021 (current situation), 2030 (red lines), and 2050 (green lines).
Figure 10. Regional Potential Index (RPI) calculated for each region and different years: 2021 (current situation), 2030 (red lines), and 2050 (green lines).
Energies 16 03042 g010
Table 1. Electrical energy consumption (GWh) for the residential building stock of each region and national zone: data from the National Electricity Network [6,7,8,9,10,11,12,13].
Table 1. Electrical energy consumption (GWh) for the residential building stock of each region and national zone: data from the National Electricity Network [6,7,8,9,10,11,12,13].
National Zones20142015201620172018201920202021
Valle d’Aosta178.4175.9176.6176.6177.9165.7161.0156.2
Piemonte4579.34627.14538.64554.34555.64545.34623.24534.8
Liguria1729.91737.51701.01693.01698.81687.31699.51686.5
Lombardia10,999.511,341.411,124.311,258.911,333.811,511.611,456.711,346.1
Trentino Alto Adige1195.21149.21156.21148.61160.11164.01158.91160.9
Veneto5195.55570.45396.55552.75595.55688.05644.35747.4
Friuli Venezia Giulia1316.41369.41340.21381.41391.21383.01377.41397.1
Emilia Romagna4900.05201.75041.25136.25143.55159.85174.85199.8
Toscana4032.94110.54026.94082.14087.04126.34156.84146.2
Umbria912.0935.4907.6926.3921.6925.2938.4945.4
Marche1520.01555.21513.21537.21546.41543.71567.31584.6
Lazio6699.96852.96670.56686.36456.36322.465186551.6
Abruzzo1286.41320.91286.61304.81294.21318.11317.71337.1
Molise284.4286.4279.8282.4276.1277.7281.0284.8
Campania5351.95484.15260.15347.65312.15443.85532.35633.0
Puglia3988.54160.73996.74168.64100.64133.94175.44397.9
Basilicata490.3498.9488.5503.2494.0495.6501.1512.0
Calabria1998.12044.81984.22041.91992.22036.32036.22120.7
Sicilia5481.85614.15340.655525436.95433.25666.25974.6
Sardegna2114.52150.52074.72156.62164.02277.12225.72335.5
Northwest17,487.117,881.917,540.517,682.817,766.117,909.917,940.417,723.6
Northeast12,607.113,290.712,934.113,218.913,290.313,394.813,355.413,505.2
Centre13,164.813,45413,118.213,231.913,011.312,917.613,180.513,227.8
South13,399.613,795.813,295.913,648.513,469.213,705.413,843.714,285.5
Islands7596.37764.67415.37708.67600.97710.37891.98310.1
Total64,254.966,18764,30465,490.765,137.865,63866,211.967,052.2
Table 2. The total number of photovoltaic installations installed each year (-): data provided by the Energy Services Manager [14,15,16,17,18,19].
Table 2. The total number of photovoltaic installations installed each year (-): data provided by the Energy Services Manager [14,15,16,17,18,19].
National Zones201620172018201920202021
Valle d’Aosta161017381833192519722094
Piemonte39,35041,97644,64148,03050,06054,141
Liguria620466777219781182828792
Lombardia87,34394,721102,340111,356119,000131,822
Trentino Alto Adige16,71517,56818,28419,05619,00420,287
Veneto83,89190,15097,453106,419113,993126,203
Friuli Venezia Giulia25,78427,15928,66030,32331,48033,395
Emilia Romagna59,07563,57268,18973,72477,77384,471
Toscana30,70532,56534,60436,99938,42041,666
Umbria13,23813,97114,92915,82916,46616,077
Marche18,88720,26321,31522,73123,60724,924
Lazio39,90643,52647,15951,26854,32858,368
Abruzzo13,24015,20016,11817,20517,43718,005
Molise274829483049321432823367
Campania22,51424,11025,81627,81728,78131,077
Puglia30,90336,23538,11740,64442,55142,782
Basilicata495953935612597459946186
Calabria17,36718,54619,50920,67621,25522,539
Sicilia37,11141,12343,63446,72748,88850,930
Sardegna28,43530,24831,64333,38434,22635,484
Northwest134,507145,112156,033169,122179,314196,849
Northeast185,465198,449212,586229,522242,250264,356
Centre102,736110,325118,007126,827132,821141,035
South91,731102,432108,221115,530119,300123,956
Islands65,54671,37175,27780,11183,11486,414
Total579,985627,689670,124721,112756,799812,610
Table 3. Annual photovoltaic panel power output (MW): data provided by Energy Services Manager [14,15,16,17,18,19].
Table 3. Annual photovoltaic panel power output (MW): data provided by Energy Services Manager [14,15,16,17,18,19].
National Zones201620172018201920202021
Valle d’Aosta8.09.09.010.09.010.0
Piemonte198.0209.0220.0235.0232.0253.0
Liguria26.029.031.034.034.037.0
Lombardia390.0421.0453.0493.0516.0578.0
Trentino Alto Adige80.090.094.097.088.092.0
Veneto393.0421.0451.0491.0509.0568.0
Friuli Venezia Giulia126.0129.0135.0143.0145.0155.0
Emilia Romagna271.0287.0306.0330.0330.0361.0
Toscana139.0148.0156.0166.0166.0182.0
Umbria62.066.070.074.073.073.0
Marche93.0100.0104.0110.0106.0111.0
Lazio183.0199.0213.0230.0239.0257.0
Abruzzo71.084.088.093.088.091.0
Molise16.017.018.019.018.018.0
Campania118.0126.0134.0144.0145.0158.0
Puglia159.0188.0196.0207.0206.0206.0
Basilicata29.031.032.033.031.032.0
Calabria96.0106.0111.0117.0114.0120.0
Sicilia199.0221.0232.0247.0250.0262.0
Sardegna136.0148.0154.0161.0159.0163.0
Northwest622.0668.0713.0772.0791.0878.0
Northeast870.0927.0986.01061.01072.01176.0
Centre477.0513.0543.0580.0584.0623.0
South489.0552.0579.0613.0602.0625.0
Islands335.0369.0386.0408.0409.0425.0
Total2793.03029.03207.03434.03458.03727.0
Table 4. Theoretical total roof surface area required for photovoltaic panel installations every year (km2).
Table 4. Theoretical total roof surface area required for photovoltaic panel installations every year (km2).
National Zones201620172018201920202021
Valle d’Aosta0.040.040.040.050.040.05
Piemonte0.981.031.091.161.151.25
Liguria0.130.140.150.170.170.18
Lombardia1.932.082.242.442.552.86
Trentino Alto Adige0.400.450.460.480.440.46
Veneto1.942.082.232.432.522.81
Friuli Venezia Giulia0.620.640.670.710.720.77
Emilia Romagna1.341.421.511.631.631.79
Toscana0.690.730.770.820.820.90
Umbria0.310.330.350.370.360.36
Marche0.460.490.510.540.520.55
Lazio0.910.981.051.141.181.27
Abruzzo0.350.420.440.460.440.45
Molise0.080.080.090.090.090.09
Campania0.580.620.660.710.720.78
Puglia0.790.930.971.021.021.02
Basilicata0.140.150.160.160.150.16
Calabria0.470.520.550.580.560.59
Sicilia0.981.091.151.221.241.30
Sardegna0.670.730.760.800.790.81
Northwest3.083.303.533.823.914.34
Northeast4.304.594.885.255.305.82
Centre2.362.542.692.872.893.08
South2.422.732.863.032.983.09
Islands1.661.831.912.022.022.10
Total13.8214.9815.8616.9917.1118.44
Table 5. Annual growth rates (%) of photovoltaic installations (GRPhV) adopted for the forecasting analysis for each region.
Table 5. Annual growth rates (%) of photovoltaic installations (GRPhV) adopted for the forecasting analysis for each region.
RegionsGRPhV-1GRPhV-2GRPhV-3GRPhV-4
Valle d’Aosta5.45.66.54.3
Piemonte6.66.97.55.7
Liguria7.27.38.06.6
Lombardia8.68.49.37.8
Trentino Alto Adige4.04.55.42.7
Veneto8.58.39.37.6
Friuli Venezia Giulia5.35.65.84.9
Emilia Romagna7.47.78.16.8
Toscana6.36.47.25.4
Umbria4.05.26.12.4
Marche5.75.86.54.9
Lazio7.98.28.77.3
Abruzzo6.45.39.23.5
Molise4.23.85.42.7
Campania6.77.37.65.9
Puglia6.95.59.73.5
Basilicata4.64.66.42.5
Calabria5.45.76.34.7
Sicilia6.65.98.05.0
Sardegna4.54.65.53.6
Italy7.07.27.76.4
Table 6. Annual development rates (%) of photovoltaic technology (DRP-PhV) adopted for the forecasting analysis for each region.
Table 6. Annual development rates (%) of photovoltaic technology (DRP-PhV) adopted for the forecasting analysis for each region.
Regions2016–20172017–20182018–20192019–20202020–2021Mean
Valle d’Aosta5.65.36.8−1.39.15.1
Piemonte12.50.011.1−10.011.14.9
Liguria11.56.99.70.08.87.4
Lombardia7.97.68.84.712.08.2
Trentino Alto Adige12.54.43.2−9.34.53.1
Veneto7.17.18.93.711.67.7
Friuli Venezia Giulia2.44.75.91.46.94.3
Emilia Romagna5.96.67.80.09.46.0
Toscana6.55.46.40.09.65.6
Umbria6.56.15.7−1.40.03.4
Marche7.54.05.8−3.64.73.7
Lazio8.77.08.03.97.57.0
Abruzzo18.34.85.7−5.43.45.4
Molise6.35.95.6−5.30.02.5
Campania6.86.37.50.79.06.1
Puglia18.24.35.6−0.50.05.5
Basilicata6.93.23.1−6.13.22.1
Calabria10.44.75.4−2.65.34.6
Sicilia11.15.06.51.24.85.7
Sardegna8.84.14.5−1.22.53.7
Italy9.15.26.6−1.56.25.1
Table 7. Building units (grouped into “n. 1”, “n. 2”, “n. 3–4”, “n. 5–8”, “n. 9–15”, and “n. ≥16”) distribution (%): breakdown by geographical area in Italy, number of building floors (“one floor”, “two floors”, “three floors”, and “four and more floors”), and building type (single-family house—SFH and multi-family house—MFH).
Table 7. Building units (grouped into “n. 1”, “n. 2”, “n. 3–4”, “n. 5–8”, “n. 9–15”, and “n. ≥16”) distribution (%): breakdown by geographical area in Italy, number of building floors (“one floor”, “two floors”, “three floors”, and “four and more floors”), and building type (single-family house—SFH and multi-family house—MFH).
ZonesSFHMFH
1 Floor2 Floors3 Floors≥4 Floors
n. 1n. 1n. 2n. 3–4n. 2n. 3–4n. 5–8n. 3–4n. 5–8n. 9–15n. ≥16
Piemonte0.31.50.30.10.90.30.80.70.11.01.7
Valle d’Aosta0.00.00.00.00.10.00.10.10.00.00.1
Liguria0.10.30.20.00.20.10.40.30.00.51.1
Lombardia0.41.71.11.51.30.82.10.50.32.23.4
Trentino Alto Adige0.00.20.00.00.30.10.30.30.00.20.2
Veneto0.31.50.80.90.90.40.90.20.20.90.8
Friuli Venezia Giulia0.10.50.00.00.40.10.20.20.00.30.3
Emilia Romagna0.21.00.60.40.70.41.20.70.11.21.2
Toscana0.30.90.50.50.60.40.90.40.10.80.9
Umbria0.10.30.10.00.20.10.20.20.00.10.1
Marche0.10.40.10.00.40.20.40.40.00.30.3
Lazio0.50.70.50.80.60.40.80.20.41.32.1
Abruzzo0.10.50.10.00.40.10.30.30.00.30.3
Molise0.00.20.00.00.10.00.10.10.00.10.1
Campania0.50.90.61.30.80.40.50.00.60.91.4
Puglia1.40.50.51.10.60.00.00.00.80.81.0
Basilicata0.10.20.10.00.10.10.10.10.00.10.1
Calabria0.40.70.30.10.50.20.50.50.10.40.4
Sicilia1.31.50.40.11.50.50.91.20.10.81.0
Sardegna0.40.70.20.00.30.10.30.30.00.30.3
Northwest0.83.51.61.62.61.33.21.50.43.86.3
Northeast0.63.21.41.32.31.02.61.40.42.62.6
Centre0.92.31.31.41.91.02.31.20.52.63.4
South2.62.91.62.42.50.81.51.11.52.43.3
Islands1.72.20.60.11.80.61.21.50.11.11.3
Total6.714.37.93.79.75.212.49.31.412.516.9
Table 8. Net surface distribution (%) of building units (BU): breakdown for the geographical area of Italy (NW = Northwest, NE = Northeast, C = Centre, S = South, and I = Islands) and building type (single-family house—SFH and multi-family house—MFH).
Table 8. Net surface distribution (%) of building units (BU): breakdown for the geographical area of Italy (NW = Northwest, NE = Northeast, C = Centre, S = South, and I = Islands) and building type (single-family house—SFH and multi-family house—MFH).
Building Type AreaNet Surface Area Distribution of the Building Units (%)
≤29 *30–3940–4950–5960–7980–99100–119120–149≥150
SFHNW0.00.00.20.52.23.63.12.94.6
NE0.00.00.10.31.63.03.33.45.9
C0.00.00.10.31.62.92.82.53.6
S0.00.10.20.52.66.26.56.07.9
I0.00.00.20.41.83.94.84.65.6
MFH (2 floors)NW0.00.31.01.86.49.36.85.77.7
NE0.00.10.30.52.33.73.43.25.1
C0.00.10.40.72.83.82.92.33.0
S0.00.20.40.73.05.74.83.64.1
I0.00.00.10.10.40.80.80.70.7
MFH (3 floors)NW0.00.31.11.96.99.87.26.08.2
NE0.00.10.30.62.54.03.73.35.1
C0.00.10.40.72.63.62.82.22.9
S0.00.10.20.41.52.82.41.82.1
I0.00.10.20.41.52.72.92.22.4
MFH (≥4 floors)NW0.00.31.11.97.09.97.26.08.3
NE0.00.10.30.52.13.32.92.64.0
C0.00.10.40.72.94.03.12.43.1
S0.00.10.30.52.03.93.32.52.9
I0.00.10.20.31.22.22.31.81.9
* Order of magnitude of the values shown in this column is around 0.0043 on average.
Table 9. Assessment of the mean roof surface area (km2) of existing buildings by varying the roof pitch.
Table 9. Assessment of the mean roof surface area (km2) of existing buildings by varying the roof pitch.
ZonesSFHMFHTotal25°30%
Piemonte41.8546.7488.5897.7429.32
Valle d’Aosta1.190.071.261.390.42
Liguria8.087.4415.5317.135.14
Lombardia51.63251.99303.62335.01100.50
Trentino Alto Adige5.522.768.289.132.74
Veneto53.6371.34124.97137.8941.37
Friuli Venezia Giulia16.613.6820.3022.406.72
Emilia Romagna30.2458.9689.2098.4229.53
Toscana29.5539.9669.5176.6923.01
Umbria8.742.1110.8511.983.59
Marche11.896.5618.4520.366.11
Lazio32.9071.37104.27115.0534.51
Abruzzo18.004.7122.7225.067.52
Molise5.730.245.976.591.98
Campania38.4266.67105.09115.9534.78
Puglia72.9338.16111.09122.5836.77
Basilicata8.410.859.2610.223.07
Calabria36.5911.7448.3353.3216.00
Sicilia89.5860.16149.74165.2249.57
Sardegna37.826.6344.4549.0414.71
Northwest102.75306.24408.99451.27135.38
Northeast106.01136.74242.75267.8480.35
Centre83.09119.99203.08224.0767.22
South180.09122.36302.45333.72100.12
Islands127.4066.79194.18214.2664.28
Total599.33752.131351.451491.16447.35
Table 10. Mean values for the photovoltaic systems in Italy: number of installations, power, energy production, and net surface area required for each installation.
Table 10. Mean values for the photovoltaic systems in Italy: number of installations, power, energy production, and net surface area required for each installation.
National ZonesNumber
(-)
Power
(kW)
Energy
(kWh/kW)
Available Roof Surface
(km2)
Energy Consumption
(kWh)
GREC
(%)
Valle d’Aosta1862.09.21111.60.42172.3−1.36
Piemonte46,366.3224.51036.629.324566.1−0.44
Liguria7497.531.8998.75.141701.6−0.54
Lombardia107,763.7475.2978.3100.5011,310.20.01
Trentino Alto Adige18,485.790.21053.02.741158.2−0.64
Veneto103,018.2472.21010.541.375574.60.54
Friuli Venezia Giulia29,466.8138.81013.16.721373.80.35
Emilia Romagna71,134.0314.21039.129.535142.60.01
Toscana35,826.5159.51075.623.014097.50.15
Umbria15,085.069.71101.93.59926.50.19
Marche21,954.5104.01127.96.111545.00.32
Lazio49,092.5220.21110.434.516597.1−0.61
Abruzzo16,200.885.81152.87.521307.10.22
Molise3101.317.71180.71.98281.7−0.19
Campania26,685.8137.51100.334.785412.00.47
Puglia38,538.7193.71189.236.774122.70.92
Basilicata5686.331.31176.83.07497.20.24
Calabria19,982.0110.71198.516.002024.90.34
Sicilia44,735.5235.21224.949.575530.70.87
Sardegna32,236.7153.51204.614.712181.41.03
Northwest163,489.5740.71031.3135.417,750.1−0.58
Northeast222,104.71015.31028.980.413,249.10.06
Centre121,958.5553.31103.967.213,166.10.01
South110,195.0576.71166.4100.113,645.50.33
Islands76,972.2388.71214.764.37712.10.95
Total694,719.83274.71104.2447.365,522.80.09
Table 11. Comparison between the energy production with and without considering the development rates of photovoltaic power (GRP-PhV), i.e., with and without taking into account the predicted improvements in photovoltaic technology.
Table 11. Comparison between the energy production with and without considering the development rates of photovoltaic power (GRP-PhV), i.e., with and without taking into account the predicted improvements in photovoltaic technology.
National ZonesEnergy Forecasting without DRP-PhVEnergy Forecasting with DRP-PhV
2030205020302050
Northwest1513.87016.71623.37537.5
Northeast1994.58630.82122.59207.1
Centre1039.44071.61098.34313.8
South994.73188.11046.73358.6
Islands644.81875.0676.91970.5
Italy6187.224,782.26567.726,387.4
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Palladino, D.; Calabrese, N. Energy Planning of Renewable Energy Sources in an Italian Context: Energy Forecasting Analysis of Photovoltaic Systems in the Residential Sector. Energies 2023, 16, 3042. https://doi.org/10.3390/en16073042

AMA Style

Palladino D, Calabrese N. Energy Planning of Renewable Energy Sources in an Italian Context: Energy Forecasting Analysis of Photovoltaic Systems in the Residential Sector. Energies. 2023; 16(7):3042. https://doi.org/10.3390/en16073042

Chicago/Turabian Style

Palladino, Domenico, and Nicolandrea Calabrese. 2023. "Energy Planning of Renewable Energy Sources in an Italian Context: Energy Forecasting Analysis of Photovoltaic Systems in the Residential Sector" Energies 16, no. 7: 3042. https://doi.org/10.3390/en16073042

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop