Next Article in Journal
Utilization of a Telemetry Monitoring System for the Dynamics of Water Quantity and Quality in the Dadahup Swamp Irrigation Area
Previous Article in Journal
Forecasting of Banana Crop Productivity Using Geospatial Approach: A Case Study of Anand District
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Proceeding Paper

A Unified Hydrologic Framework for Flood Design Estimation in Ungauged Basins †

by
Lampros Vasiliades
1,*,
George Papaioannou
2 and
Athanasios Loukas
3
1
Department of Civil Engineering, School of Engineering, University of Thessaly, Pedion Areos, 38334 Volos, Greece
2
Department of Forestry and Management of the Environment and Natural Resources, Democritus University of Thrace, 68200 Orestiada, Greece
3
Department of Transportation and Hydraulic Engineering, School of Rural and Surveying Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
*
Author to whom correspondence should be addressed.
Presented at the 7th International Electronic Conference on Water Sciences, 15–30 March 2023; Available online: https://ecws-7.sciforum.net/.
Environ. Sci. Proc. 2023, 25(1), 40; https://doi.org/10.3390/ECWS-7-14194
Published: 14 March 2023
(This article belongs to the Proceedings of The 7th International Electronic Conference on Water Sciences)

Abstract

:
Design flood hydrograph estimation is a key problem in hydrology and is necessary for a variety of applications from the design of hydraulic structures to flood risk mapping processes. Furthermore, in large ungauged basins (>1000 km2), design flood estimation methods mainly rely on single-event theories using digital elevation models, land use/land cover and soil type data, and relevant meteorological information (temperature and rainfall data). The single event-based deterministic approach was adopted based on three modelling components: (i) a synthetic storm generator; (ii) a hydrological simulation model; and (iii) a hydrological routing model. In this study the 100-year design flood (which is assumed equal to 100-year extreme rainfall) was estimated for the Pinios River Basin, Thessaly, Greece, at Larissa outlet station (upstream of the area by about 6500 km2). The hydrological approach is based on semi-distributed modelling of the rainfall–run-off process (at the sub-basin scale) using HEC-HMS v.4.10 software and the SCS-CN method for estimating rainfall excess, as well as the unit hydrograph theory and the Muskingum hydrological flow routing method for propagating the surface run-off to the sub-basin outlets.

1. Introduction

Hydrological extremes such as extreme precipitation and severe floods have consistently posed a risk to human culture. Due to the potential rise in meteorological and hydroclimatological extremes in recent decades, the issue has received significant attention [1]. The primary input for modelling hydrological extremes is rainfall, which has both geographical and temporal characteristics that must be taken into consideration in simulation procedures. In order to design hydraulic structures, design rainfall is often estimated as a univariate variable [2]. Hence, design flood hydrograph estimation is a key problem in hydrology and is necessary for a variety of applications from the design of hydraulic structures to flood risk mapping processes. Furthermore, in large ungauged basins (>1000 km2), design flood estimation methods mainly rely on single-event theories using digital elevation models, land use/land cover and soil type data, and relevant meteorological information (temperature and rainfall data) [3].
The single event-based deterministic approach was adopted based on three modelling components: (i) a synthetic storm generator; (ii) a hydrological simulation model; and (iii) a hydrological routing model [4]. In this study, the 100-year design flood (which is assumed equal to 100-year extreme rainfall) was estimated for the Pinios River Basin, Thessaly, Greece, at Larissa outlet station (upstream area is about 6500 km2). The hydrological approach is based on semi-distributed modelling of the rainfall–run-off process (at the sub-basin scale) using HEC-HMS software and the SCS-CN method for estimating rainfall excess, as well as the unit hydrograph theory for propagating the surface run-off to the sub-basin outlets. Design rainfall at the subbasin scale is estimated from 13 intensity–duration–frequency (IDF) rainfall point curves using thiessen polygons and adjusted to the mean elevation of the sub-basin with the developed precipitation gradients. The design flood hydrograph is estimated by combining the IDF approach with standard time profiles for constructing synthetic rainfall events of a certain probability, the SCS-CN method for extracting the excess from the gross rainfall, and the unit hydrograph theory for propagating the surface run-off to the basin outlet.

2. Materials and Methods

2.1. Study Area

The design flood hydrographs were estimated for a larger part of the Pinios River Basin in Thessaly, Greece. Figure 1 shows the hydrological basin upstream of the point of interest near Larissa City with a total area of 6407 km2. The hydrographic network, depicted also shown in Figure 1, was configured in the application of Water Directive 2000/60/EC and includes the main watercourses of the study area. The most extensive and complex network of watercourses develops in the Pinios Basin, and includes, in addition to the main branch of the river, almost all its important tributaries, namely: (a) in the southern part of the basin, Enipeas, Farsaliotis, Sofaditis, and Kalentzis, (b) in the western and southwestern part, Pamisos, Portaikos, Malakasiotiko, and Murgani, and (c) in the northern part, the Litheos and Neochoritis rivers.
Based on the hydrographic network, the study area was divided into 22 watersheds and smaller sub-basins, considering nodes at the entrances of the zones and the confluences of the main watercourses of the study area. The boundaries of the basins are shown in Figure 1 and Table 1 and present the main characteristics of the sub-watersheds. In the mountainous and semi-mountainous parts of the hydrological basin, the hydrological basins were drawn based on a digital elevation model (DEM) with a pixel size of 25 × 25 m, while in the plain areas, a DEM with 5 m resolution was used across the main bed of the Pinios River combined with National Cadastre maps as well as Google Earth satellite images. The mapping based on higher resolution information was necessary in the c riverbed as well as in the lowland sections, because many of the watercourses are diverted and do not fully follow the natural slope of the ground. In addition, in some cases, embankments have been constructed on either side of the bed to prevent lateral runoff, with the result being that these embankments actually define artificial barriers. Artificial interventions in the flow are also created by other projects, such as road embankments, canals, etc. In addition, the information of the hydrographic network was integrated into the DEM (DEM reconditioning) for more accurate mapping of the flow field in the areas of low and very low gradients and for the correct mapping of the sub-basins and the accurate calculation of the geomorphological characteristics of the sub-basins and watercourses.
The run-off curve number (CN) proposed by the Soil Conservation Service (SCS, 1972) was used to condense the physiographic characteristics of the watershed into a single representative value. In the present study, it is used to estimate the maximum potential retention, which is the input data of the SCS-CN method (the method is applied to estimate hydrological deficits in the context of hydrological modelling with HEC-HMS software). The hydrological simulation model of the Pinios River Basin (just upstream of the confluence of the Pinios River with the Gousbasianiotis stream) includes 22 sub-watersehds, 20 nodes, and 19 river reaches.

2.2. Hydrological Modelling

The surface integration of IDF point measurements at the sub-basin level was carried out using the Thiessen polygon method. The calculated weights resulting from the application of the methodology were used to calculate the intensities (and rainfall heights) for durations of 5 min to 48 h and return periods from 1–1000 years according to the Thiessen method. From the calculated intensities i(d, T) according to the Thiessen method for various durations d and return periods, it is possible to adjust the equation of the rainfall ombrian curves by optimizing the five (5) parameters κ, λ′, ψ′, θ, and η at the sub-basin level. As the objective function of the optimization, the weighted root mean square error (weighted RMSE) was used, resulting from the minimization of the root mean square error of the observed and calculated intensities (RMSEintensity) and rainfall heights (RMSEdepth) for each sub-basin.
In the present study, to estimate the 100-year return period design flood, the flood return period was assumed to be equal to the return period of an extreme typical 100-year return period storm. The duration of the storm was chosen for all sub-basins to be constant and equal to 48 h so that the design storms in the sub-basins had a duration longer than the concentration time of the entire hydrological basin upstream of the point of interest. Finally, the design rainfall was distributed over time using the alternating block method (ABM). Time-distributed precipitation was used as an input hyetograph to the hydrological model to produce the hydrographs for each sub-catchment. Hydrological uncertainty has been expressed in terms of the two typical antecedent moisture conditions (AMC) that are accounted for in the Soil Conservation Service curve number (SCS-CN) approach of moderate (or average—AMCII) represented by CNII and wet (or high—AMCIII) represented by CNIII. The transformation of the excess rainfall over each sub-basin to the flood hydrograph at the outlet junction (rainfall–run-off model) was achieved using the dimensionless curvilinear unit hydrograph approach of SCS, which is considered the prevailing modelling approach for ungauged basins. A key assumption of the method was the implementation of the concept of varying the (i.e., run-off-dependent) time of concentration, which affects the shape of unit hydrographs, thus introducing further non-linearities to the overall modelling approach. Hence, in order to take account of the dependence of the response time of the basin against run-off, a kinematic-wave-theory-based semi-empirical formula was employed, considering that tc is inversely proportional to the design rainfall. Further details are given in [3,4]. HEC-HMS software was used, and the design flood hydrographs from the generated storms were estimated for all scenarios.

3. Results and Discussion

Table 2 presents the characteristics of the calculated synthetic unit hydrographs by the SCS-CN method for the 22 sub-watersheds of the study area and for the selected return period T = 100 years. In addition, Figure 2 presents the developed IDF curves and unit hydrographs from the application of the methodology for two sub-basins, the Megas sub-basin with the code name Sub04 and the mountainous sub-basin of Sofaditis (Sofaditis_3) with the code name Sub22, for selected periods return T = 5, 100, and 1000 years.
Application of the hydrological simulation model of the Pinios River Basin, which includes 22 sub-basins, 20 nodes, and 19 river reaches using (i) the developed IDF curves; (ii) the SCS-CN unit hydrograph model; and (iii) the Muskingum hydrological flow routing model, is shown in Figure 3 for the outlet J1 of the study area for the two employed scenarios and the return period of 100 years.
The design flood values for a return period of T = 100 years at the outlet of the study area, which were estimated by the application of semi-distributed methodology, are 2808 m3/s for average soil moisture conditions (CNII, average scenario) and 4571 m3/s for wet soil moisture conditions (CNIII, adverse scenario). These flood values as well as the flood hydrographs should be used in the design of hydrotechnical projects in the study area.

Author Contributions

Conceptualization, mathematical analysis, and writing—review and editing L.V., G.P. and A.L. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Blöschl, G.; Hall, J.; Viglione, A.; Perdigão, R.A.P.; Parajka, J.; Merz, B.; Lun, D.; Arheimer, B.; Aronica, G.T.; Bilibashi, A.; et al. Changing Climate Both Increases and Decreases European River Floods. Nature 2019, 573, 108–111. [Google Scholar] [CrossRef] [PubMed]
  2. Apel, H.; Thieken, A.H.; Merz, B.; Blöschl, G. Flood Risk Assessment and Associated Uncertainty. Nat. Hazards Earth Syst. Sci. 2004, 4, 295–308. [Google Scholar] [CrossRef]
  3. Papaioannou, G.; Vasiliades, L.; Loukas, A.; Alamanos, A.; Efstratiadis, A.; Koukouvinos, A.; Tsoukalas, I.; Kossieris, P. A Flood Inundation Modeling Approach for Urban and Rural Areas in Lake and Large-Scale River Basins. Water 2021, 13, 1264. [Google Scholar] [CrossRef]
  4. Papaioannou, G.; Efstratiadis, A.; Vasiliades, L.; Loukas, A.; Papalexiou, S.; Koukouvinos, A.; Tsoukalas, I.; Kossieris, P. An Operational Method for Flood Directive Implementation in Ungauged Urban Areas. Hydrology 2018, 5, 24. [Google Scholar] [CrossRef]
Figure 1. Study area with sub-watersheds, the hydrographic network, and simulation nodes in the Greek Geodetic Reference System 1987 (EPSG: 2100).
Figure 1. Study area with sub-watersheds, the hydrographic network, and simulation nodes in the Greek Geodetic Reference System 1987 (EPSG: 2100).
Environsciproc 25 00040 g001
Figure 2. The developed intensity–duration–frequency (IDF) curves for (a) the Sub04 and (b) Sub22 sub-watersheds. Synthetic unit hydrographs: (c) the Sub04 sub-watershed and (d) the Sub22 sub-watershed.
Figure 2. The developed intensity–duration–frequency (IDF) curves for (a) the Sub04 and (b) Sub22 sub-watersheds. Synthetic unit hydrographs: (c) the Sub04 sub-watershed and (d) the Sub22 sub-watershed.
Environsciproc 25 00040 g002
Figure 3. Design flood hydrographs at the outlet of the study area for the employed hydrologic scenarios and the return period of 100 years.
Figure 3. Design flood hydrographs at the outlet of the study area for the employed hydrologic scenarios and the return period of 100 years.
Environsciproc 25 00040 g003
Table 1. Sub-watershed characteristics.
Table 1. Sub-watershed characteristics.
CodeSub-WatershedArea
(km2)
Mean
Elevation (m)
Outlet
Elevation (m)
Maximum Flow Length (km)Curve Number (CNII)Time of Concentration (h)
Sub01Larisa331.15165.7761.765.61753.220.980
Sub02Piniada138.49193.4671.434.21255.811.130
Sub03Karditsa-Keramidi185.0994.6379.839.60753.836.917
Sub04Megas193.14244.8392.027.50457.79.793
Sub05Nomi-Mesdani37.7098.2384.228.22654.822.327
Sub06Neochoritis293.48489.9984.245.31770.18.470
Sub07Litheos_2114.68246.9488.429.16152.18.596
Sub08Litheos321.53288.8093.362.30460.414.766
Sub09Pamisos234.13568.0398.038.38159.26.848
Sub10Sarakina-Mesdani298.87298.6798.055.54257.913.455
Sub11Portaikos296.42629.41104.134.83059.16.605
Sub12Malakasiotikos518.53962.30236.642.67162.17.196
Sub13Mourgani440.46698.19236.661.25468.210.229
Sub14Vlochos92.6898.4283.323.08453.123.535
Sub15Kalentzis398.20321.0692.541.73458.211.776
Sub16Enipeas_1356.69201.8586.365.25356.920.166
Sub17Enipeas_2682.97524.27158.969.81459.913.685
Sub18Farsaliotis_1565.33140.9189.056.03653.931.078
Sub19Farsaliotis_2310.32299.73109.339.06655.711.690
Sub20Sofaditis_1158.58210.0593.242.67158.613.228
Sub21Sofaditis_2203.92542.48249.034.00964.77.890
Sub22Sofaditis_3234.80739.57249.027.44764.15.783
Table 2. Characteristics of SCS synthetic unit hydrographs for the return period of 100 years in all sub-watersheds.
Table 2. Characteristics of SCS synthetic unit hydrographs for the return period of 100 years in all sub-watersheds.
CodeSub-Watershedtc (h)tp (h)tb (h)Qp (m3/s)PD=48h,T=100y (mm)PD=48h,T=5y (mm)
Sub01Larisa14.0988.58442.91880.244166.275.1
Sub02Piniada7.7544.77723.88660.300172.983.9
Sub03Karditsa-Keramidi25.65415.51777.58624.810177.385.6
Sub04Megas6.9874.31721.58693.055200.0101.8
Sub05Nomi-Mesdani16.1719.82849.1387.979125.966.1
Sub06Neochoritis6.4834.01520.075152.038163.395.7
Sub07Litheos_26.4393.98919.94359.804134.475.4
Sub08Litheos11.0426.75033.75199.076135.675.8
Sub09Pamisos5.1583.22016.099151.245216.7122.9
Sub10Sarakina-Mesdani10.0266.14130.703101.237139.377.4
Sub11Portaikos4.8933.06115.304201.430226.9124.5
Sub12Malakasiotikos5.5753.47017.350310.816230.5138.4
Sub13Mourgani7.6254.70023.500194.924176.798.2
Sub14Vlochos16.2389.86849.33819.535195.693.1
Sub15Kalentzis8.2795.09325.463162.639211.4104.5
Sub16Enipeas_113.7198.35641.78288.784179.683.1
Sub17Enipeas_29.6965.94329.714239.040207.9104.4
Sub18Farsaliotis_120.66812.52662.62893.879175.977.8
Sub19Farsaliotis_27.8104.81124.056134.160181.581.0
Sub20Sofaditis_18.9015.46527.32760.352191.686.8
Sub21Sofaditis_25.3633.34316.714126.882210.397.2
Sub22Sofaditis_34.0162.53512.674192.678232.9112.3
Note: tc: adjusted time of concentration, tp: time to peak, tb: base time, Qp: peak run-off, PD=48h,T=100y: extreme rainfall for the rain duration of 48 h and T = 100 years, PD=48h,T=5y: extreme rainfall for the rain duration of 48 h and T = 5 years.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Vasiliades, L.; Papaioannou, G.; Loukas, A. A Unified Hydrologic Framework for Flood Design Estimation in Ungauged Basins. Environ. Sci. Proc. 2023, 25, 40. https://doi.org/10.3390/ECWS-7-14194

AMA Style

Vasiliades L, Papaioannou G, Loukas A. A Unified Hydrologic Framework for Flood Design Estimation in Ungauged Basins. Environmental Sciences Proceedings. 2023; 25(1):40. https://doi.org/10.3390/ECWS-7-14194

Chicago/Turabian Style

Vasiliades, Lampros, George Papaioannou, and Athanasios Loukas. 2023. "A Unified Hydrologic Framework for Flood Design Estimation in Ungauged Basins" Environmental Sciences Proceedings 25, no. 1: 40. https://doi.org/10.3390/ECWS-7-14194

Article Metrics

Back to TopTop