Proceeding Paper

Rapid Chloride Permeability Test of Mortar Samples with Various Admixtures †

by
Miriama Čambál Hološová
1,*,
Adriana Eštoková
1 and
Miloslav Lupták
2
1
Institute for Sustainable and Circular Construction, Faculty of Civil Engineering, Technical University of Kosice, Vysokoskolska 4, 04200 Kosice, Slovakia
2
Institute of Materials and Quality Engineering, Faculty of Materials, Metallurgy and Recycling, Technical University of Kosice, Vysokoskolska 4, 04200 Kosice, Slovakia
*
Author to whom correspondence should be addressed.
Presented at the 4th International Conference on Advances in Environmental Engineering, Ostrava, Czech Republic, 20–22 November 2023.
Eng. Proc. 2023, 57(1), 36; https://doi.org/10.3390/engproc2023057036
Published: 8 December 2023

Abstract

:
This paper is focused on the permeability of cement composite samples with various admixtures. Permeability was examined by the rapid chloride permeability test due to the simple and relatively quick performance among the many methods. Permeability is one of the durability parameters considering the pore system of the composite structure. Ion diffusion provides information about inner pore structure by passing a charge through the sample. In real-life conditions, not only chlorides but also other ions can penetrate into the structure and cause corrosion. Various cement supplements were used as admixtures. The reference sample consisted of cement, fine sand, and water, while the rest of the samples consisted of 20% blast furnace slag, bypass dust, eggshells or recycled glass instead of the cement. The results showed lower permeability in samples containing blast furnace slag and eggshells and a higher charge passage in samples with recycled glass and bypass dust than for the reference sample.

1. Introduction

Concrete is exposed to different aggressive attacks due to various environmental conditions. The durability of concrete can be defined as the resistance to physical or chemical deterioration caused by environmental interaction. Coastal areas and materials in direct contact with water, acid rain, airborne ions, or ions found in de-icing salt are the main sources of aggressive ions that encounter the material, and the activity of aggressive ions causes the corrosion of the structure of the composite cement material. Aggressive ions penetration and transport through the concrete is a process that can take place through a number of mechanisms such as diffusion and convection, among others. When the concentration of ions on the outside of the concrete member is higher than on the inside, the diffusion process occurs [1,2,3,4]. Convection transport is only applicable to concrete structures that are in contact with liquid under a pressure head, such as liquid-retaining structures, and is expressed as the rate of flow of liquids through a porous material caused by a pressure head. Therefore, it depends on the pore structure and the viscosity of the liquids or gases involved. Dissolved ions and gases are therefore transported by convection with penetrating water into the concrete [5].
In the past, the durability of concrete used to be specified by maximum water–cement ratio and minimum cement content. The development of materials allowed for the use of various additives and admixtures, including secondary raw materials. This made it more difficult to determine the fundamentals of durability properties. Chemical deterioration is differentiated from physical deterioration by chemical interactions between constituents [6]. The case studies that Metha mentioned in [4] reaffirmed that the key to overall durability is the permeability of the concrete rather than its chemistry. The term permeability generally describes the durability of a material, specifically it describes the ability of liquid to move through the concrete.
To determine the permeability of the material, several methods can be used. Methods can be categorized into the three categories: diffusion test, migration test, and indirect test based on resistivity and conductivity. Among the useable methods are the following: European method EN 13396 (immersion test for repair products and system), Nordest methods NT BUILD 433 (immersion test) and NT BUILD 492 (rapid migration test), INSA steady-state migration test, multi-regime migration test, and resistivity test. The rapid chloride permeability test (RCPT) is method defined in two American standards, ASTM C 1202 [7] and AASHTO T 277 [8], widespread in the USA and Canada, and used in the present research. The methods used have been confirmed to be performance-based specifications, which also include measurements based on the principle of the transport of chloride ions, especially in conditions where the materials are exposed to the influence of the environment [4,9]. RCPT, also known as the Coulomb Test, was first developed by Whiting in 1981 [10]. The RCPT is often utilized for its easy performance and time efficiency.
It was found that several parameters, which were examined by appropriate test methods, were related to different mechanisms of chloride transport. These parameters included the following: chloride diffusion coefficient, capillary absorption, sorptivity, initial surface absorption, the volume of permeable voids, compressive strength, water permeability coefficients, chloride migration, water–cement ratio, etc. [4,11]. The rate of chloride ion ingress into concrete is primarily dependent on pore size, pore distribution, and the interconnectivity of the pore system. The pore structure depends on other factors such as mix design, the type of cement and other mix constituents, the use of supplementary cementitious materials, construction practices, concrete mix proportions, the degree of hydration, compaction, and curing conditions. Whenever the potential risk of chemical corrosion is impended, the concrete should be evaluated for chloride permeability [11,12,13,14,15].
This paper is focused on determining the permeability of various waste-based cement materials investigated by measuring the chloride ions penetration. Measured admixtures were selected to test traditional and non-traditional wastes. The test of ion transportation aimed to obtain more information about the material’s internal structure and porosity system, which will provide information about the permeability and durability of the material, by simulating an accelerated model scenario of aggressive ions entering the material from the environment.

2. Materials and Methods

The fundamental tenet of the test is the passage of a charge through the sample during the 6 h test. According to [16] measured specimens with the diameter of 100 mm and thickness of 50 mm (obtained by sawing the central part of 100 × 200 mm concrete cylinders) should be used.
A constant voltage of 60 V was passing through the sealed sample. The sample was in contact with solutions on both sides; one side had a NaCl solution, and the other side had a NaOH solution according to standard [16]. To prevent sample from leaking, the sample was sealed with silicone putty. The samples were in contact with the solutions through a circular cross-section (as shown Figure 1) with sample dimensions of 44 mm circular diameter (on average) and 28 mm mean diameter. This RCP test has been modified to smaller dimensions compared to the guidelines. On the one hand, due to the difference in the composition of the mixtures, a mortar sample was used instead of a concrete sample, and on the other hand, due to the repeated current trend, the time frame was consequently shortened to 90 min.
The amount of current passed through the sealed sample in mA at a constant voltage of 60 V ± 1 V was measured during a period of 90 min. Every minute, the highest and lowest value of the current in mA was recorded. To determine the permeability of mortar samples, the total charge (Q(total)) passed through the mortars was calculated based on the maximum current detected within the 90 min measuring interval according to [16]:
Q ( t o t a l ) = 0 t I d t [ C ]
where:
Q—Charge (C);
I—Current (A);
t—Time (s).
The calculations of the total charge (Q(total)) according to the standard [4], considering the 360-min duration of the test, was comparable to the results of other studies. Q(total) was established in accordance with the recurring current transition trend from the current charge achieved during 90 min.
The investigated preparations consisted of a reference sample (CEM) comprising a mix of Ordinary Portland Cement, fine sand, and water. The other samples had the cement component replaced by 20 wt.% of admixtures from secondary raw materials. The high chloride resistance of concrete depends on the type of cement and maximum water–cement ratio [17]. According to [4], concrete with a water-to-cement ratio of 0.38 reports a much lower permeability than the concrete with a water-to-cement ratio of 0.52. In the present research, the water coefficient was set to 0.5 for all mixtures, according to [18].
Blast furnace slag (BFS), bypass dust (BD), eggshells (ESs), and recycled glass (RG) were the secondary raw materials used in the cement composite samples as the 20 wt.% cement (CEM) supplement. Mixtures were taken from the bulk sample into round molds with dimensions of 44 × 28 mm and left for hydration for 28 days. After a period of 28 days, the samples were saturated with water for at least an hour before the RCP test to achieve a faster current increase.

3. Results and Discussion

The values of maximum passed current (Imax) through the individual samples measured during the 90 min experiment are reported in Table 1. These maximum values were used to calculate the charge transfer according to Equation (1).
A comparison of the results of ion penetration between composite samples with supplementation and reference composite sample showed lower permeability for samples with BFS and ES, but higher permeability for samples with BD and RG by more than 30% (Table 1). However, this measurement provided only preliminary input data of the samples. Measured samples contain pozzolanic and latent hydraulic materials, which are subjected to continuous hydration processes, hardening of matrix, and changes in the inner structure.
Figure 2 represents the charge passed through each sample measured during a 6 h test according to the standard test method [7].
The sample with blast furnace slag (BFS) substitute and with eggshells (ESs) had a lower ion transition than the cement reference sample (CEM). The low permeability of the BFS samples corresponded with the results of the study [19]. Samples with bypass replacement (BD) and glass (RG) showed the highest ion permeability. The results for cement kiln dust (BD) from study [20] corresponded with the results obtained in the present research.
To express the differences in ion penetration and thus permeability among the samples with individual cement substitutes and reference sample, the charge index (CHI) was calculated by dividing the values of calculated total charges Q(total) of a sample with supplement and the reference sample:
C H I = Q t o t a l ( i ) Q t o t a l ( r e f )
where:
Q(total)(i) is the total charge calculated per individual sample (C);
Q(total)(ref) is the total charge calculated for reference sample (C).
Figure 3 shows results of charge indexes of composites with supplementations in relation to the reference sample.
The charge transport does not depend only on the chlorides contained in the test solution, but also on the chlorides contained in the sample. Therefore, the sample with bypass dust content was optimized by interpolation calculation, and despite this, it turned out that the structure of the composite is the most permeable among investigated mixtures. This implies that the porous system of the structure is richer in pores filled with air or water, which allows for the passage of not only chloride ions in the pore solution of the composite but also the passage of other ions, for example, OH, SO42−, Na+, Ca2+, etc., which participate in concrete corrosion [12].

4. Conclusions

The present work was focused on the estimation of the permeability of the cement composite material with different admixtures comprising secondary raw materials in comparison with a reference cement composite sample without admixture. The pore system of the material structure can lead to the corrosion of the material caused by ion penetration to the inner structure. To investigate the permeability of the material, the rapid chloride permeability test was used. RCPT is widely used test thanks to its relatively quick and simple performance. The results represent the amount of the passing charge transported through the sample under a constant voltage, which shows the permeability of the inner structure. The results showed a higher permeability for samples with bypass dust and recycled glass admixtures than the reference sample. On the other hand, a lower permeability than the reference sample was measured for blast-furnace-slag- and eggshell-based composites. The improvement in terms of decreasing the permeability was found for blast furnace slag samples by up to 30%.
Further investigations including the performance of X-ray fluorescence and diffraction analysis of the samples will provide more information about changes in the compound composition of the materials’ structure.

Author Contributions

Conceptualization, A.E. and M.Č.H.; methodology, M.Č.H.; investigation, M.Č.H. and M.L.; writing—original draft preparation, M.Č.H. and A.E.; writing—review and editing, A.E. All authors have read and agreed to the published version of the manuscript.

Funding

This study was carried out as part of the project solution and has been supported by Scientific Grant Agency of the Ministry of Education, science, research and sport of the Slovak Republic and the Slovak Academy of Sciences, projects VEGA Grant No. 1/0230/21 and 2/0108/23.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available upon request from the corresponding author.

Conflicts of Interest

The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

References

  1. Jau, W.C.; Tsay, D.S. A study of the basic engineering properties of slag cement concrete and its resistance to seawater corrosion. Cem. Concr. Res. 1998, 28, 1363–1371. [Google Scholar] [CrossRef]
  2. Sanchez, T.; Conciatori, D.; Keserle, G.C. Influence of the type of the de-icing salt on its diffusion properties in cementitious materials at different temperatures. Cem. Concr. Res. 2022, 128, 104439. [Google Scholar] [CrossRef]
  3. Joshi, P.; Chan, C. Rapid chloride permeability testing. Concr. Constr. 2002, 47, 37–43. [Google Scholar]
  4. Concrete, C.; Australia, A. Chloride resistance of concrete. In International Concrete Abstracts Portal; CCAA: Sydney, Australia, 2009. [Google Scholar]
  5. Wee, T.H.; Suryavanshi, A.K.; Tin, S.S. Evaluation of rapid chloride permeability test (RCPT) results for concrete containing mineral admixtures. Mater. J. 2000, 97, 221–232. [Google Scholar]
  6. Iffat, S.; Emon, A.B.; Manzur, T.; Ahmad, S.I. An experiment on durability test (RCPT) of concrete according to ASTM standard method using low-cost equipments. Adv. Mater. Res. 2014, 974, 335–340. [Google Scholar] [CrossRef]
  7. C1202-18; Standard Test Method for Electrical Indication of Concrete’s Ability to Resist Chloride Ion Penetration. ASTM International: West Conshohocken, PA, USA, 2012.
  8. AASHTO T 277; Standard Method of Test for Electrical Indication of Concrete’s Ability to Resist Chloride Ion Penetration. American Association of State Highway and Transportation Officials: Washington, DC, USA, 2011.
  9. Huang, K.S.; Yang, C.C. Using RCPT determine the migration coefficient to assess the durability of concrete. Constr. Build. Mater. 2018, 167, 822–830. [Google Scholar] [CrossRef]
  10. Whiting, D. Rapid Determination of the Chloride Permeability of Concrete; Final Report Portland Cement Association: Skokie, IL, USA, 1981. [Google Scholar]
  11. Chen, Y.; Ji, T.; Yang, Z.; Zhan, W.; Zhang, Y. Sustainable use of ferronickel slag in cementitious composites and the effect on chloride penetration resistance. Constr. Build. Mater. 2020, 240, 117969. [Google Scholar] [CrossRef]
  12. Zych, T. Test methods of concrete resistance to chloride ingress. Czas. Tech. 2015, 6-B, 117–139. [Google Scholar]
  13. Fenaux, M.; Reyes, E.; Gálvez, J.C.; Moragues, A. Modelling the transport of chloride and other ions in cement-based materials. Cem. Concr. Compos. 2019, 97, 33–42. [Google Scholar] [CrossRef]
  14. Huang, K.-S.; Yang, C.-C. Using the Chloride Penetration Depth Obtained from Rcpt to Assess the Permeability of Concrete. J. Environ. Sci. Technol. 2020, 28, 2–5. [Google Scholar]
  15. Abeywickrama, H.M.; Nanayakkara, S.M.A. Applicability of RCPT for performance-based durability design of reinforced concrete structures. Civil Engineering Research Symposium 2023. In Proceedings of the Civil Engineering Research Symposium 2023, Moratuwa, Sri Lanka, 27 September 2023. [Google Scholar]
  16. ASTM C1202-12; Standard Test Method for Electrical Indication of Concrete’s Ability to Resist Chloride ion Penetration. ASTM International: West Conshohocken, PA, USA, 2012; Volume 100, pp. 1–8.
  17. Shi, C. Effect of mixing proportions of concrete on its electrical conductivity and the rapid chloride permeability test (ASTM C1202 or ASSHTO T277) results. Cem. Concr. Res. 2004, 34, 537–545. [Google Scholar] [CrossRef]
  18. STN EN 206-1 (STN 73 2403); Concrete. Part 1: Specification, Performance, Production and Conformity. Publication No. 85349:72; Slovak Institute for Technical Normalization: Bratislava, Slovakia, 2002.
  19. Sengul, O.; Tasdemir, M.A. Compressive strength and rapid chloride permeability of concretes with ground fly ash and slag. J. Mater. Civ. Eng. 2009, 21, 494–501. [Google Scholar] [CrossRef]
  20. Kunal; Siddique, R.; Rajor, A.; Singh, M. Influence of bacterial-treated cement kiln dust on strength and permeability of concrete. J. Mater. Civ. Eng. 2016, 28, 04016088. [Google Scholar] [CrossRef]
Figure 1. Apparatus for RCP test according to [12] (photo by author).
Figure 1. Apparatus for RCP test according to [12] (photo by author).
Engproc 57 00036 g001
Figure 2. Total charge Q(total) passed through the reference composite sample and cement samples with supplements.
Figure 2. Total charge Q(total) passed through the reference composite sample and cement samples with supplements.
Engproc 57 00036 g002
Figure 3. Charge indexes for the cement samples.
Figure 3. Charge indexes for the cement samples.
Engproc 57 00036 g003
Table 1. Measured maximum currents (Imax) per reference sample (CEM) and cement samples with supplements.
Table 1. Measured maximum currents (Imax) per reference sample (CEM) and cement samples with supplements.
SampleCEMBFSBDESRG
Current Imax (mA) *55.5231.871.652.672.9
* Maximum current in milliamperes.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Hološová, M.Č.; Eštoková, A.; Lupták, M. Rapid Chloride Permeability Test of Mortar Samples with Various Admixtures. Eng. Proc. 2023, 57, 36. https://doi.org/10.3390/engproc2023057036

AMA Style

Hološová MČ, Eštoková A, Lupták M. Rapid Chloride Permeability Test of Mortar Samples with Various Admixtures. Engineering Proceedings. 2023; 57(1):36. https://doi.org/10.3390/engproc2023057036

Chicago/Turabian Style

Hološová, Miriama Čambál, Adriana Eštoková, and Miloslav Lupták. 2023. "Rapid Chloride Permeability Test of Mortar Samples with Various Admixtures" Engineering Proceedings 57, no. 1: 36. https://doi.org/10.3390/engproc2023057036

Article Metrics

Back to TopTop