Next Article in Journal
Preparation of a Fluorescent Peptide Substrate to Target Tumor-Associated Macrophages
Previous Article in Journal
In Silico Approaches for the Study of New Anti-Parkinson’s Agents
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Proceeding Paper

Chromo-Fluorogenic Detection of Cyanide Ion with a Cyanine Probe †

by
Cátia D. F. Martins
,
Maria Manuela M. Raposo
and
Susana P. G. Costa
*
Centre of Chemistry, University of Minho, Campus de Gualtar, 4710-057 Braga, Portugal
*
Author to whom correspondence should be addressed.
Presented at the 27th International Electronic Conference on Synthetic Organic Chemistry (ECSOC-27), 15–30 November 2023; Available online: https://ecsoc-27.sciforum.net/.
Chem. Proc. 2023, 14(1), 64; https://doi.org/10.3390/ecsoc-27-16109
Published: 15 November 2023

Abstract

:
Due to the extreme toxicity of cyanide in biological systems and its widespread presence in the environment, great efforts have been focused on developing sensitive and selective methods for cyanide detection. In this regard, sulfo-cyanine dye 1 was evaluated as a colorimetric and fluorimetric probe for various anions. Chemosensing studies revealed that this compound exhibited remarkable selectivity and sensitivity for CN in acetonitrile solution, with a marked colour change from cyan to colourless and fluorescence emission switched off. The detection limit was estimated to be as low as 0.45 μM, and the binding mode was studied using NMR techniques.

1. Introduction

The adverse health effects caused by specific anions underscore the importance of easy and straightforward anion recognition. Excessive levels of anions such as cyanide or nitrate can disturb physiological processes, leading to health problems. For instance, cyanide ions (CN) are highly toxic because of their ability to bind to the ferric form of cytochrome-c in the mitochondrial electron transport chain. This binding disrupts the production of adenosine triphosphate (ATP) and thereby inhibits cellular respiration. However, cyanide is widely used in a variety of industrial processes, including in paper, textiles, and plastics manufacturing methods, as well as in metallurgy for electroplating and gold and silver extraction [1,2]. Therefore, the selective and sensitive detection of cyanide ions is essential for human well-being, environmental preservation, and the advancement of scientific and medical knowledge in the context of cyanide exposure.
Nowadays, optical chemosensors designed for anion detection are highly attractive for biological and environmental applications because of their simplicity, cost-effectiveness, real-time response, and ease of detection through optical changes (colour and/or fluorescence) without requiring advanced equipment [2,3,4]. This provides reliable quantitative and qualitative analyses for a variety of analytes. Over the past years, various promising optical chemosensors have been developed for sensing cyanide ions [2,4,5,6,7,8]. Among these probes, cyanine dyes offer numerous advantages, including high sensitivity, tunable optical properties, and biocompatibility, making them valuable tools in analytical chemistry and biosensing applications [9].
Following our previous work focused on the synthesis of a sulfo-cyanine dye and its evaluation as an optical chemosensor for cations [10,11], we now report its chromo-fluorogenic ability for anion detection in acetonitrile solution. Therefore, the interaction of this compound with several anions was evaluated via preliminary chemosensing studies, followed by UV/Vis, fluorescence and NMR titrations.

2. Experimental Section

2.1. Instruments and Materials

UV/Vis absorption spectra were obtained using a Shimadzu UV/2501PC spectrophotometer (Shimadzu Europa GmbH, Duisburg, Germany), and fluorescence spectra were collected using a FluoroMax-4 spectrofluorometer (HORIBA Europe GmbH, Darmstadt, Germany) in standard quartz cuvettes with a 1 cm optical path. NMR spectra were recorded on a Bruker Avance III 400 (Bruker, Billerica, MA, USA) at an operating frequency of 400 MHz for 1H and 100.6 MHz for 13C, using the solvent peak as the internal reference at 25 °C; the chemical shift values (δ relative to TMS) are given in ppm. All commercially available reagents were used as received. The synthesis and structural characterization of dye 1 in MeOH-d4 has been reported by us elsewhere [10]. In this report, NMR spectra were obtained in DMSO-d6.
1H NMR (400 MHz, DMSO-d6): δ = 1.30–1.38 (2H, m, CH2-c), 1.45–1.53 (2H, m, CH2-b), 1.65–1.70 (14H, m, CH2-d and 4xCH3), 1.92 (2H, t, J = 7.2 Hz, CH2-e), 3.58 (1H, s, NCH3), 4.06 (2H, t, J = 7.2 Hz, CH2-a); 6.25 (1H, d, J = 14.4 Hz, H-α or H-α′), 6.29 (1H, d, J = 14.4 Hz, H-α or H-α′), 6.57 (1H, t, J = 12.4 Hz, H-γ), 7.29 (2H, d, J = 8.0 Hz, H-7 and H-7′), 7.62 (2H, dd, J = 1.6 and 8.0 Hz, H-6 and H-6′), 7.79 (2H, d, J = 1.2 Hz, H-4 and H-4′), 8.34 (2H, t, J = 13.2 Hz, H-β and H-β′) ppm.
13C NMR (100.6 MHz, DMSO-d6): δ = 25.66 (CH2-b), 26.26 (CH2-c), 26.83 (CH2-d), 26.93 (2xCH3), 27.09 (2xCH3), 31.19 (NCH3), 37.07 (CH2-e), 43.52 (CH2-a), 48.81 (C-3 or C-3′), 48.85 (C-3 or C-3′), 103.36 (C-α or C-α′), 103.59 (C-α or C-α′),110.00 (C-7 or C-7′), 110.11 (C-7 or C-7′), 119.81 (C-4 or C-4′), 119.90 (C-4 or C-4′), 125.68 (C-γ), 125.96 (C-6 or C-6′), 126.07 (C-6 or C-6′), 140.37 (C-3a or C-3a′), 140.48 (C-3a or C-3a′),142.00 (C-7a′), 142.72 (C-7a), 145.16 (C-5 or C-5′), 145.25 (C-5 or C-5′), 154.13 (C-β or C-β′), 154.17 (C-β or C-β′), 172.86 (C-2′), 173.57 (C-2), 174.51 (C=O) ppm.

2.2. Stock Solutions

Evaluation of dye 1 as a colorimetric and fluorimetric chemosensor was carried out in the presence of various anions (F, I, Br, CN, ClO4, HSO4, NO3, BzO, H2PO4, and CH3COO) in the form of hydrated tetrabutylammonium salts. Solutions of dye 1 (ca. 1.0 × 10−5 to 5.0 × 10−6 M) and the selected anions (ca. 1.0 × 10−2 to 5.0 × 10−4 M) were prepared in UV-grade acetonitrile.

2.3. Preliminary Chemosensing Studies and Titrations

Preliminary chemosensing studies were performed by addition of 20 equivalents of each ion to the solution of compound 1. Spectrophotometric and spectrofluorimetric titrations were carried out by sequential addition of the ion to the solution of 1 (3 mL), and the absorption and fluorescence spectra were measured until reaching the maximum optical change. Emission scans were recorded via excitation at 590 nm, with a 3 nm slit. NMR titrations were carried out by similar gradual addition of the ion (6.0 × 10−1 M) to the solution of 1 (2.0 × 10−2 M) in DMSO-d6 at 25 °C.

2.4. Determination of the Detection Limit (DL)

The detection limit (DL) was calculated using the equation DL = 3σ/S, where σ is the standard deviation of the fluorescent intensity of the analyte-free solution, and S is the slope of the linear plot of concentration-dependent fluorescence response [12].

3. Results and Discussion

3.1. Preliminary Chemosensing Studies

In our previous work, we reported the synthesis and photophysical characterization of sulfo-cyanine 1 (Figure 1), as well as its evaluation as an efficient colorimetric probe for cations, especially for Cu2+ and Fe3+ [10,11]. Here, we study the sensing ability of this compound for different anions with environmental and medicinal relevance.
Firstly, the selectivity of probe 1 towards the selected anions was evaluated via naked-eye perceivable colour changes through the addition of 20 equivalents of each anion to the solution of 1. This compound displayed a selective response in the presence of CN, showing a remarkable colour change from cyan to colourless (Figure 2). No obvious colorimetric change was observed upon the addition of the other ions to the solution.
Furthermore, the fluorimetric behaviour of probe 1 was also studied by recording the fluorescence intensity of 1 before and after the addition of the selected anions. It was found that probe 1 exhibited a complete quenching of fluorescence upon interaction with CN, while other ions did not induce relevant changes (Figure 3).

3.2. Spectrophotometric and Spectrofluorimetric Titrations

Considering the most promising result in both colorimetric and fluorescence preliminary chemosensing studies, the interaction of probe 1 with CN was evaluated via spectrophotometric and spectrofluorimetric titrations in acetonitrile solution. The ion-free solution showed an intense absorption band at 651 nm (εmax = 136,304 M−1 cm−1) and a strong fluorescence intensity at 672 nm (Figure 4).
It was found that probe 1 exhibited a decrease in absorbance and fluorescence intensity in response to increasing amounts of cyanide. Notably, the sensitivity of 1 towards CN was evident, as the addition of a low number of equivalents (0.4 equiv.) was enough to cancel the absorbance and for the complete quenching of fluorescence. The molar extinction coefficient for the chemodosimeter 1-CN (651 nm) was found to be εmax = 1544 M−1 cm−1).
Based on fluorimetric titration, the detection limit (DL) of 1 for CN was calculated by using the DL = 3σ/S method [12]. The DL for CN was found to be 0.45 μM, which is lower than the WHO limit for cyanide in drinking water (1.9 μM) [13]. Overall, the results suggest that compound 1 could be used as an efficient chromofluorescent probe for CN with high sensitivity in acetonitrile solution.

3.3. NMR Studies

The mode of the complexation of probe 1 with CN was further investigated through the use of 1H NMR titrations. Upon the addition of cyanide ions, the aromatic and vinyl protons attributed to probe 1 disappeared, while a set of new signals appeared (Figure 5a). This result is close to those described by Qiu et al. [7], suggesting that the chemodosimeter Cy5-CN is likely a product of a nucleophilic addition. In this reaction, CN acted as a nucleophile in the nucleophilic addition at one of the iminium carbons of the indolium salts of Cy5, as strongly indicated by the shifts observed for protons adjacent to the nitrogen atoms. Indeed, a comparison of the 13C NMR spectrum of probe 1 with 13C NMR and DEPT 135 spectra of probe 1 with 0.5 equiv. of CN confirms the presence of new quaternary carbon signals at 80.04 and 117.62 ppm, which could be ascribed to the cyano group carbon and C2, respectively (Figure 5b). These results suggest the formation of a new species, such as 2 (Figure 6).

4. Conclusions

In summary, we have reported a cyanine dye-based chromofluorescent chemosensor, which exhibited various advantageous properties, including a high molar absorption coefficient at 651 nm (εmax = 136,304 M−1 cm−1); a selective and sensitive response towards CN, showing a remarkable colour change from cyan to colourless and a complete quenching of fluorescence with a low detection limit (0.45 μM). NMR studies suggest a mechanism involving nucleophilic addition of cyanide to the iminium carbon. Therefore, probe 1 could be used to detect cyanide ions qualitatively (naked eye) and quantitatively (UV-Vis and fluorescence spectroscopy) with high sensitivity in acetonitrile solution.

Author Contributions

Conceptualization, C.D.F.M. and S.P.G.C.; methodology, C.D.F.M. and S.P.G.C.; validation, S.P.G.C. and M.M.M.R.; formal analysis, C.D.F.M., M.M.M.R. and S.P.G.C.; investigation, C.D.F.M.; resources, S.P.G.C. and M.M.M.R.; writing—original draft preparation, C.D.F.M.; writing—review and editing, C.D.F.M., M.M.M.R. and S.P.G.C.; supervision, S.P.G.C. and M.M.M.R.; project administration, S.P.G.C. and M.M.M.R.; funding acquisition, S.P.G.C. and M.M.M.R. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by Fundação para a Ciência e Tecnologia—FCT (Portugal) through CQ-UM (UID/QUI/00686/2020), project PTDC/QUI-OUT/3143/2021 and a PhD grant to C. D. F. Martins (SFRH/BD/05277/2020). The NMR spectrometer Bruker Avance III 400 is part of the National NMR Network and was purchased within the framework of the National Program for Scientific Re-equipment, contract REDE/1517/RMN/2005 with funds from POCI 2010 (FEDER) and FCT.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available in the article.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Xu, J.-F.; Chen, H.-H.; Chen, Y.-Z.; Li, Z.-J.; Wu, L.-Z.; Tung, C.-H.; Yang, Q.-Z. A Colorimetric and Fluorometric Dual-Modal Chemosensor for Cyanide in Water. Sens. Actuators B Chem. 2012, 168, 14–19. [Google Scholar] [CrossRef]
  2. Udhayakumari, D. Chromogenic and Fluorogenic Chemosensors for Lethal Cyanide Ion. A Comprehensive Review of the Year 2016. Sens. Actuators B Chem. 2018, 259, 1022–1057. [Google Scholar] [CrossRef]
  3. Gale, P.A.; Caltagirone, C. Fluorescent and Colorimetric Sensors for Anionic Species. Coord. Chem. Rev. 2018, 354, 2–27. [Google Scholar] [CrossRef]
  4. Wang, F.; Wang, L.; Chen, X.; Yoon, J. Recent Progress in the Development of Fluorometric and Colorimetric Chemosensors for Detection of Cyanide Ions. Chem. Soc. Rev. 2014, 43, 4312–4324. [Google Scholar] [CrossRef] [PubMed]
  5. Lv, X.; Liu, J.; Liu, Y.; Zhao, Y.; Sun, Y.-Q.; Wang, P.; Guo, W. Ratiometric Fluorescence Detection of Cyanide Based on a Hybrid Coumarin–Hemicyanine Dye: The Large Emission Shift and the High Selectivity. Chem. Commun. 2011, 47, 12843–12845. [Google Scholar] [CrossRef] [PubMed]
  6. Niu, H.-T.; Jiang, X.; He, J.; Cheng, J.-P. Cyanine Dye-Based Chromofluorescent Probe for Highly Sensitive and Selective Detection of Cyanide in Water. Tetrahedron Lett. 2009, 50, 6668–6671. [Google Scholar] [CrossRef]
  7. Qiu, D.; Liu, Y.; Li, M.; Chen, H.; Li, H. Near-Infrared Chemodosimetric Probes Based on Heptamethine Cyanine Dyes for the “Naked-Eye” Detection of Cyanide in Aqueous Media. J. Lumin. 2017, 185, 286–291. [Google Scholar] [CrossRef]
  8. Chen, X.; Nam, S.-W.; Kim, G.-H.; Song, N.; Jeong, Y.; Shin, I.; Kim, S.K.; Kim, J.; Park, S.; Yoon, J. A Near-Infrared Fluorescent Sensor for Detection of Cyanide in Aqueous Solution and Its Application for Bioimaging. Chem. Commun. 2010, 46, 8953–8955. [Google Scholar] [CrossRef] [PubMed]
  9. Sun, W.; Guo, S.; Hu, C.; Fan, J.; Peng, X. Recent Development of Chemosensors Based on Cyanine Platforms. Chem. Rev. 2016, 116, 7768–7817. [Google Scholar] [CrossRef] [PubMed]
  10. Martins, C.D.F.; Raposo, M.M.M.; Costa, S.P.G. Synthesis and Characterization of a Water-Soluble Pentamethine Indocyanine Dye for Peptide Labeling. Chem. Proc. 2022, 8, 91. [Google Scholar]
  11. Martins, C.D.F.; Raposo, M.M.M.; Costa, S.P.G. A Sulfo-Cyanine Dye as a Colorimetric Chemosensor for Metal Cation Recognition. Eng. Proc. 2022, 27, 12. [Google Scholar]
  12. Li, S.; Zhang, D.; Xie, X.; Ma, S.; Liu, Y.; Xu, Z.; Gao, Y.; Ye, Y. A Novel Solvent-Dependently Bifunctional NIR Absorptive and Fluorescent Ratiometric Probe for Detecting Fe3+/Cu2+ and Its Application in Bioimaging. Sens. Actuators B Chem. 2016, 224, 661–667. [Google Scholar] [CrossRef]
  13. Pan, H.; Liu, Y.; Liu, S.; Ou, Z.; Chen, H.; Li, H. A Dual-Function Colorimetric Probe Based on Carbazole-Cyanine Dyad for Highly Sensitive Recognition of Cyanide and Hypochlorous Acid in Aqueous Media. Talanta 2019, 202, 329–335. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Structure of probe 1.
Figure 1. Structure of probe 1.
Chemproc 14 00064 g001
Figure 2. Colorimetric responses of probe 1 in acetonitrile solution (1.0 × 10−5 M) before and after the addition of 20 equiv. of various anions.
Figure 2. Colorimetric responses of probe 1 in acetonitrile solution (1.0 × 10−5 M) before and after the addition of 20 equiv. of various anions.
Chemproc 14 00064 g002
Figure 3. Normalized fluorescence responses of probe 1 at 672 nm (λexc = 590 nm) in acetonitrile solution (5.0 × 10−6 M) before and after the addition of 20 equiv. of various anions.
Figure 3. Normalized fluorescence responses of probe 1 at 672 nm (λexc = 590 nm) in acetonitrile solution (5.0 × 10−6 M) before and after the addition of 20 equiv. of various anions.
Chemproc 14 00064 g003
Figure 4. Spectrophotometric (left) and spectrofluorimetric (right) titration of probe 1 with CN in acetonitrile solution: [1] = 5.0 × 10−6 M. Inset: absorption at 651 nm and emission at 672 nm as a function of added anion equivalents.
Figure 4. Spectrophotometric (left) and spectrofluorimetric (right) titration of probe 1 with CN in acetonitrile solution: [1] = 5.0 × 10−6 M. Inset: absorption at 651 nm and emission at 672 nm as a function of added anion equivalents.
Chemproc 14 00064 g004
Figure 5. NMR studies: (a) partial 1H NMR spectra of 1 before and after the addition of 0.5 equiv. of CN (* overlap of water signal in the DMSO-d6 solution); (b) partial 13C NMR (top) and DEPT 135 (bottom) of 1 with CN (0.5 equiv.) in DMSO-d6 (* indicates new cyano group carbon and C2).
Figure 5. NMR studies: (a) partial 1H NMR spectra of 1 before and after the addition of 0.5 equiv. of CN (* overlap of water signal in the DMSO-d6 solution); (b) partial 13C NMR (top) and DEPT 135 (bottom) of 1 with CN (0.5 equiv.) in DMSO-d6 (* indicates new cyano group carbon and C2).
Chemproc 14 00064 g005
Figure 6. Suggested structure for species 2.
Figure 6. Suggested structure for species 2.
Chemproc 14 00064 g006
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Martins, C.D.F.; Raposo, M.M.M.; Costa, S.P.G. Chromo-Fluorogenic Detection of Cyanide Ion with a Cyanine Probe. Chem. Proc. 2023, 14, 64. https://doi.org/10.3390/ecsoc-27-16109

AMA Style

Martins CDF, Raposo MMM, Costa SPG. Chromo-Fluorogenic Detection of Cyanide Ion with a Cyanine Probe. Chemistry Proceedings. 2023; 14(1):64. https://doi.org/10.3390/ecsoc-27-16109

Chicago/Turabian Style

Martins, Cátia D. F., Maria Manuela M. Raposo, and Susana P. G. Costa. 2023. "Chromo-Fluorogenic Detection of Cyanide Ion with a Cyanine Probe" Chemistry Proceedings 14, no. 1: 64. https://doi.org/10.3390/ecsoc-27-16109

Article Metrics

Back to TopTop