Next Article in Journal
A Parametric Study on the LDB Strength of Steel-Concrete Composite Beams
Next Article in Special Issue
Commercial Level Analysis of P2P vs. Net-Metering Comparing Economic and Technical Indexes
Previous Article in Journal
Assessment of Techniques for Detection of Transient Radio-Frequency Interference (RFI) Signals: A Case Study of a Transient in Radar Test Data
Previous Article in Special Issue
The Evaluation of Green Building’s Feasibility: Comparative Analysis across Different Geological Conditions
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Decentralized Biogas Production in Urban Areas: Studying the Feasibility of Using High-Efficiency Engines

by
Rubén González
1,
José García-Cascallana
2,
Javier Gutiérrez-Bravo
2 and
Xiomar Gómez
2,*
1
Department of Electrical, Systems and Automatic Engineering, School of Industrial, Computer and Aeronautical Engineering, Campus de Vegazana s/n, University of León, 24071 León, Spain
2
Department of Chemistry and Applied Physics, Chemical Engineering Area, Campus de Vegazana s/n, University of León, 24071 León, Spain
*
Author to whom correspondence should be addressed.
Eng 2023, 4(3), 2204-2225; https://doi.org/10.3390/eng4030127
Submission received: 26 July 2023 / Revised: 17 August 2023 / Accepted: 22 August 2023 / Published: 24 August 2023
(This article belongs to the Special Issue Green Engineering for Sustainable Development 2023)

Abstract

:
The study examines decentralized waste treatment in an urban setting with a high-density population of 2500 inhab./km2. The co-digestion of food and garden waste was assumed by using several mid-size digesters, while centralized biogas and digestate valorization was considered. The studied configuration generates electricity and thermal energy, covering 1.3% of the residential electricity demand and 3.2% of thermal demand. The use of double-turbocharged engines under the most favorable scenario aids cities in reaching sustainability goals. However, the location of treatment plants is a factor that may raise social discomfort and cause a nuisance to citizens. Locating waste plants near residential areas causes discomfort due to possible odors, gaseous emissions, and housing market distortions. Such problematic aspects must be addressed for the decentralized alternative to work. These factors are of great relevance and must be given a practical solution if the circular economic model is to be implemented by considering the insertion of waste streams into the production system and generating local energy sources and raw materials.

1. Introduction

Anaerobic digestion is considered a technology capable of transforming organic wastes into energetic products and obtaining digestate as a by-product that is susceptible to valorization in agriculture. Although widely spread, the implementation of this technology still experiences high installation costs, making its application unfeasible on small- and medium-sized systems. In addition, the recent events regarding the war scenario in Ukraine are putting much pressure on obtaining energy sources and gaseous fuels from local resources. Anaerobic digestion may be an excellent ally in the production of local gaseous fuels but may also have several disadvantages regarding the complexity of the biological process and the need for qualified personnel to perform daily tasks and keep an adequate maintenance of industrial equipment.
Decentralized waste treatment has gained attention in recent years due to the lower impacts associated with collection, transport, and the ease of controlling the process parameters when treating smaller waste quantities [1,2]. However, there are limits based on reasonableness in terms of the distance wastes are to be transported from the collecting point to the centralized treatment center [3]. Therefore, treating wastes locally has been proposed as a suitable alternative for low-populated areas, small livestock farms, or developing countries, where treating organic wastes may serve as a local source of biogas for cooking. This strategy, although technically feasible in some regions, faces several constraints regarding climatic conditions and substrate characteristics. Wang [4] reported that several digesters installed in China and Nepal were not operating at optimal conditions, and up to 50% were not functional after a short period. Similar reports regarding the installation and operating conditions of small digesters in China and India expressed concerns regarding low biogas production and inefficient operation [5,6,7].
Other researchers assessed the performance of small digestion units in Egypt and reported on the feasibility of these small plants [8]. These authors considered in their analysis only biofertilizers derived from digestate as a valuable product, disregarding energy production. A different evaluation also dealt with small-scale digestion systems, but in this case, using a prototype. The authors reported a higher energy demand per unit of biogas produced when compared with large-scale units [3], making the process non-competitive.
Further proliferation of small-scale digesters in developing countries may aid in significantly reducing global emissions of methane [9]. However, these digesters must remain operative during their whole life cycle. Luo et al. [10] studied different small-scale digestion units in China (30–200 m3), stating that with some technical improvement and maintaining operation at ambient conditions, these small units with a simple configuration may attain biogas productivities of 0.47 m3/m3reactor d. In addition, these authors indicated that farmers could perform the operating and maintenance tasks of small digesters after some basic training.
On the other side of the coin, centralized digestion does not face a clear horizon. Large-scale plants take advantage of economies of scale, but these plants may confront social rejection when integrated into mega-farm projects. The large number of animals held in large-scale farms allows for reducing costs and keeping better control of health risks. An increase in farm scale also makes it easier to comply with guidelines and guarantee animal welfare so that animals are raised and slaughtered humanely [11]. However, any attempt to increase the efficiency of meat production systems collides with the general trend of rejecting industrial animal production [12].
Anaerobic digestion is the best biological option for treating high-organic-strength effluents, but the methane potential of manures may not be high enough to assure plant feasibility. This fact, in addition to other factors such as high installation costs and the high price of co-substrates, may represent significant barriers to increasing the implementation of digestion technology in many countries [13,14]. Velásquez Piñas et al. [15] analyzed the Brazilian scenario of biogas plants using mono-substrates, such as cattle manure. These authors indicated that digestion was feasible if an electrical power higher than 740 kWe was installed. This value was increased to 1000 kWe when co-digestion was considered. In a different study, González et al. [16] evaluated the techno-economic feasibility of treating sheep manure considering a farm size of 2000 animals and electricity production from biogas. Even under the assumption of co-digestion, the system had low economic feasibility. Imeni et al. [17] reported results regarding the feasibility of a cattle farm with 250 adult animals. Profitability was only achieved if co-digestion with raw briquette straw was implemented.
Digestion technology has been successfully applied in the farm and agro-industrial sectors. However, the focus has shifted to extrapolating this experience from anaerobic digestion gained in different waste treatment sectors into urban areas as a means of locally treating food waste. This approach benefits from lower distances for transporting wastes and obtaining a local source of biogas. However, the final disposal of digestate is still pending a clear solution since, if not properly solved, this factor may threaten the whole implementation of the process [18]. The decentralized approach considers the presence of several small units for digesting the material. It should also consider the use of low-emission vehicles for waste collection and pretreatments to reduce the mass of residues and minimize odors [19].
Despite the feasibility of installing small digestion units, there are other factors needing optimization. The valorization of biogas by combined heat and power (CHP) units is heavily penalized since the electricity conversion efficiency is higher for large-capacity engines. In contrast, smaller ones are limited by efficiencies of about 34% [20]. It should be assessed whether a decentralized waste treatment system would be more practical than the current centralized system. In previous work, the authors of this paper evaluated the feasibility of producing biogas using small-scale digestion systems in urban and rural areas [21]. In their previous work, biogas derived from small digestion systems could scarcely cover 5.8% of a home’s thermal demand. If electricity production is considered, then small-scale digestion and in situ biogas valorization are not a good couple. It seems more reasonable to assume a hybrid approach where biogas is produced in a decentralized way and converted into electricity in high-efficiency engines.
The amount of electricity expected from food waste derived from urban areas could be about 2.4–4.1% of the total electrical demand of the population. This value was estimated by Nguyen et al. [22] for the Vietnam case, representing a motivating factor to search for an optimal configuration capable of integrating sustainability principles, energy production, and circularity goals. However, the local treatment of waste needs to consider several aspects regarding reactor design, operating conditions, climatic factors, and social aspects [1,23]. Win et al. [24] analyzed the decentralization scheme by considering waste treatment at high-producing centers. These authors indicated that subsidies and incentives are needed to attain economic feasibility. However, after so many years of experience in digestion technology development, the focus should be placed on attaining a profitable process, otherwise this technology may not become a real driver in the energy sector. Experience already gained in the digestion of manures and the treatment of agronomic waste may be useful in adapting technologies for the local treatment of wastes in urban areas.
Decentralization may aid in increasing social consciousness regarding materials reuse and cycling, thus making citizens aware of the impact caused by their daily activities on the environment. Treating waste as close as possible to the generation point increases social responsibility regarding consumption habits and reduces the discarding rate. The decentralized approach is yet full of challenges due to its intrinsic lower efficiency and higher installation costs. It is important, therefore, to find an equilibrium between the expected theoretical benefits and the discomfort that may be created due to the proximity of waste treatment centers. The present manuscript assessed a hybrid approach of waste treatment and biogas valorization, assuming decentralized anaerobic digestion and a centralized biogas valorization unit using CHP engines. The present study considered practical aspects regarding the location of decentralized plants in current existing cities and the space availability for implementing decentralized proposals. The energy production potential was obtained by assuming food and yard wastes as feeding material. Estimations of electricity and thermal energy were carried out considering the engine’s efficiency and seasonal climatic conditions.

2. Materials and Methods

2.1. Engine Description

The engine studied was a double turbocharged engine with a high efficiency. The biogas engine was a lean-burn, four-stroke Otto cycle, Jenbacher type JGS 320 GS-BL. This engine consisted of two inlet mixture compression stages and two intercooler stages with plate heat exchangers. Combustion took place under lean-burn conditions using spark ignition from spark plugs. The compressors were driven by the exhaust gases expanded in the turbines. Both components were mechanically coupled by means of a rotating shaft. The arrangement of the cylinders was based on two rows of ten units in a V-shape. Analysis of this engine was based on Cascallana et al. [25]. This engine was fueled by biogas and used an electronic carburetor to mix the incoming gases before compressing them in the first compression stage. Each of the two rows of cylinders had a turbocharger consisting of a centrifugal compressor driven by a centripetal turbine, which used exhaust gases for its operation. The intercoolers were air-to-water heat exchangers cooled by the main and auxiliary circuits.
Table 1 shows the geometric parameters of the engine.
Engine operating and performance parameters are shown in Table 2. Table 3 contains the characteristics and operating parameters of the turbochargers. The tolerances were ±5% for biogas consumption (biogas composition was assumed as CH4 65% and CO2 35%) and ±8% for the other parameters. The loading degree was considered to be 100% for a methane flow rate corresponding to a biogas flow rate of 458 kg/h with a 65% methane content. The power was determined at operating conditions at standard reference conditions as per ISO/3046/1 [27]: altitude 100 m above sea level (a.s.l.), pressure 100 kPa, temperature 25 °C, and humidity 30%. The volume was reported at standard conditions for biogas, combustion air and exhaust gases, pressure 101 kPa, and temperature 0 °C [28].
The engine cooling system is shown schematically in Figure 1, representing the main and auxiliary circuits. The purpose of the three-way thermostatic valves was to regulate the thermal power exchanged by the use of recirculating water without flowing through the plate heat exchangers. This allowed for adapting the water mass flow to all circumstances based on the degree of loading and, therefore, the amount of thermal energy transferred. When the engine was at full load, the flow through the bypass was zero, and all the energy was transferred. However, a fraction of the water flow was bypassed at a lower loading, reducing the amount that finally reached the heat exchanger.

2.2. Engine Performance Equations

Figure 2 shows the general operating scheme of the cogeneration system, considering the cooling circuit coupled to a heat recovery unit. The cogeneration system had two different cooling circuits, the main and the auxiliary. Each of these circuits had a plate heat exchanger that divided them into primary and secondary circuits. The primary section of the main circuit was responsible for cooling the engine block, the cylinder heads, the oil circuit inside the CHP unit, intercooler 2 of the twin-turbo system [28], and the heat recovery system of the exhaust gas. The main circuit in its second section allowed for thermal energy to be transferred to other devices via a heat exchanger or dissipated in the cooling tower. The auxiliary circuit cooled intercooler 1 via its primary circuit [28], while the secondary circuit dissipated the thermal energy in cooling towers. This thermal energy was disregarded due to its low temperature, which made its use difficult, containing just a small share of the total energy contained in the biogas. The primary section of both cooling circuits used a 37% glycol solution in water as the heat transfer fluid to prevent freezing when the engine was out of service.
Mass and energy balances were established for the double turbocharger. The numbers in Figure 2 were used to indicate the different calculation sections. The parameters obtained from compression were used to estimate those of the turbine. The power developed by the turbine was that necessary to drive the compressor after considering mechanical losses during power transmission by the common shaft.
The mass flow of the combustion mixture, Mmix, (biogas and air, Mbiogas and Mair) was estimated by Equation (1), and this value is conserved, thus being the same for the mass flow of exhaust gases (Meg). The mass ratio of biogas to air is represented by parameter F in Equation (2).
M m i x = M e g = M a i r · ( 1 + F )
F = M b i o g a s / M a i r
The twinning energy balance is the ratio of the mechanical power (P) between the compressor and turbine, as shown by Equations (3) and (4).
P T 1 = P C 2 / η m e c 2 T 1
P T 2 = P C 1 / η m e c 1 T 2
where subscripts 1 and 2 represent the first and second stages, and T and C, also used as subscripts, stand for turbine and compressor. Thus, PT1 represents the turbine power in stage 1. The mechanical efficiency is here denoted by ηmec. ηmec1 C2−T1 and ηmec1 C2−T1 were assumed to be 97% at most. This was due to the intrinsic limits of the turbine–compressor system, which set restrictions to the full recovery of energy from the exhaust gases when the nominal compression ratio was reached.
The compressor and turbine rotational speeds (nC, nT) were also twinned. The relationship between these speeds is shown in Equations (5) and (6). The subscripts 1 and 2 again represent the stage analyzed.
n C 1 = n T 2
n C 2 = n T 1
Equation (7) estimates the mechanical power developed by the engine (Peng).
P e n g = V · 2 · n N · 1 60 · M E P
where V is the total displacement volume of the cylinder per cycle (0.04867 m3/cycle), n is the engine rotation speed (1500 rpm), and N is the number of engine strokes (4 strokes/cycle). MEP (mean effective pressure) is a theoretical parameter representing the average pressure during a complete cycle and gives an idea of the effective work achieved (1800 kPa).
Equation (8) gives the engine MEP, where ρadm−a and ρbio are the densities of air and biogas, respectively, at the entrance to the combustion chamber. LHV is the lower heating value of biogas, and ηV and ηe are the volumetric and combustion efficiencies of the engine, respectively. ηV and ηe depended on the loading degree and were calculated by least-squares adjustment to keep consonance with the MEP value given by the manufacturer.
M E P = ρ a d m a · η V · F · L H V ρ b i o · η e
The specific heat of air (cp−air), the fuel–air mixture (cp−mix), and exhaust gases (cp−eg) were considered equivalent. The specific heat of air was obtained from Equation (9) [32].
c p a i r = R · ( 3.56839 6.788729 · 10 4 · T + 1.5537 · 10 6 · T 2 3.29937 · 10 12 · T 3 4.66395 · 10 13 · T 4 )
The compression ratio (rC) is estimated as the proportion between the inlet and outlet pressure. For the first-stage compressor, subscript 0 was used to indicate the inlet and 1 to represent the outlet stream. Compression was assumed isentropic; thus, it was equivalent pin Equation (10) when considering the isentropic ratio, where p1 is substituted by p1s.
r C 1 = p 1 / p 0 = p 1 s / p 0
The compression ratios used for the first and second stages of compression were 1.85 and 2.57, respectively [26]. The initial pressure was 101.3 kPa. The isentropic outlet temperature T1s was calculated using Equation (11).
T 1 s = T 0 · 1 r C 1 1 γ γ
The specific heat ratio (γ) was 1.4 for air, and the initial temperature (T0) was 25 °C. The isentropic efficiency (ηis−C1) is the ratio of the temperature increase that takes place under real and ideal compression conditions according to Equation (12). Subscripts 1 and 2 were used for the first or second stages, respectively. The isentropic efficiencies for the first and second stages were 75% [29].
η i s C 1 = T 1 s T 0 T 1 T 0
The compressor power (PC1) was calculated from Equation (13)
P C 1 = M m i x 3600 · c p m i x · T 1 T 0
The power of the intercooler (PINT1) was estimated from Equation (14) using the difference in the temperature conditions between the inlet point (T1) and outlet point (T2). The pressure after a cooling stage was estimated assuming the behavior of the gas mixture to be an ideal gas.
P I N T 1 = M m i x 3600 · c p m i x · T 1 T 2
The equations are equivalent for the second compressor and intercooler. In this case, the outlet condition for the compressor used subscript 3, and the outlet condition for the intercooler used subscript 4. Equations (15)–(18)—for turbine 1—were used to estimate the power (PT1), isentropic efficiency (ηis−T1), inlet pressure (p5), and the expansion ratio (rex-T1). The nomenclature used in these equations was set by considering subscript 5 to identify the inlet condition and 6 for the outlet stream.
P T 1 = P C 1 η m e c 1 = M e g 3600 · c p e g · T 6 T 5
η i s T 1 = T 5 T 6 T 5 T 6 s
p 5 = p 6 · T 5 T 6 s γ γ 1
r e x T 1 = p 5 / p 6 = p 5 / p 6 s
The isentropic temperature and pressure are denoted by T6s and p6s. The expansion ratio, calculated as the ratio between the inlet and outlet pressure, was considered here to be equivalent to that of the isentropic condition. The same equations were applied for turbine 2 using subscripts 6 and 7 to indicate the inlet and outlet streams. The power associated with chimney energy recovery (PER) was calculated by Equation (19). The inlet and outlet points are identified by subscripts 7 and 8.
P E R = M e g 3600 · c p e g · T 7 T 8

2.3. Methodology for Evaluating Decentralized Biogas Production in Mid-Size Communities

The efficiency of small-scale digesters is reduced with decreasing their size because the energy demand of the auxiliary equipment associated with the reactor operation does not follow a linear relationship. Different digester sizes were assumed by considering working conditions under different hydraulic retention times (HRT). The treatment of a mixture of food and garden waste was assumed by considering a population of 150,000 inhabitants with a mean population density of 2500 inhab./km2. Assumptions for the input materials are specified in Table 4. A 60% methane content in the biogas was assumed. The digestion process was assumed to be run under mesophilic conditions at a total solid (TS) feed content of 11%. Biogas production from the waste mixture was estimated by disregarding synergies between co-substrates.
Daily biogas production (DBP, expressed in m3/d) was calculated based on Equation (20)
D B P = W P × N ° i n h a b × T S × % V S × S M P 365,000 × [ C H 4 ]
where WP is the waste production factor either for food waste or garden waste (expressed as kg waste/inhab. year). inhab. stands for the number of inhabitants considered, TS is the total solid content of the waste, %VS is the content of volatile solids of the waste expressed as a percentage, SMP is the specific methane production, and [CH4] is the methane composition of biogas. A range of 5% variation was assumed for the SMP, TS, and VS content of the feed. A Monte Carlo simulation was carried out using the Excel® MSO 2016 (16.0.4266.1001) software.
The digester volume was calculated by considering the working volume of the reactor and assuming a head space equivalent to 30% of the total digester volume. The working volume (Vworking) was set as a variable parameter ranging from 50 to 500 m3, thus calculating the number of reactors needed to treat the volumetric flow of wastes (Qtotal, m3/d) at a TS content of 110 g/L.
Q t o t a l = N ° d i g e s t e r s × Q i
where digesters is the number of digesters needed to treat the mass of waste produced daily. Qi is the volumetric flow set as input for a single digester. This flow was estimated considering the working volume of the reactor and the HRT, as expressed in Equation (22).
Q i = V w o r k i n g H R T
The total volumetric flow of wastes was obtained from the mass flow of TS produced daily (FmTS) and the concentration of TS of the feed [TS] expressed in terms of kg/m3.
Q t o t a l = F m T S [ T S ]
The digester dimension was estimated considering a cylinder with equivalent magnitudes for the diameter and height and a core formed by a spherical cap with a height equivalent to a sixth of the cylinder diameter. The estimation of the decentralized plant size was based on the reactor cylinder base dimension using a multiplying factor of 20. The electricity demand for the treatment plants was estimated as 15% of the electricity produced at full engine load. The thermal demand of the digesters was estimated considering the heat needed to increase the temperature of the feed from ambient temperature (5 °C in winter and 20 °C in summer) to the digestion temperature (37 °C). The specific heat value (Cp) of the feeding slurry was assumed to be equivalent to that of water (4200 J/kg °C). The thermal demand of the digestion plant was estimated as shown in Equation (24).
Q ˚ d i g e s t i o n = F f e e d × C p × T
where digestion is the heat required to increase the temperature of the feed from ambient conditions to the fermentation temperature. Ffeed is the mass flow of feed introduced into the digester daily, and ΔT is the thermal gradient. The thermal losses of the digester were estimated assuming a value of 1.2 W/m2 °C for the heat transfer coefficient of the digester wall and a value of 0.95 W/m2 °C for the digester cap.
Q ˚ l o s s = U × A × T
where loss is the thermal loss of the digester, U is the heat transfer coefficient, and A is the area available for heat transfer. The thermal loss of the digester was estimated by summing the losses from the wall and the digester cap. The total heat demand was the heat demanded to treat the mixture of wastes produced daily.
Q ˚ t o t a l   d e m a n d = N ° d i g e s t e r s × ( Q ˚ d i g e s t i o n + Q ˚ l o s s )
The electricity demand for Spain was 5259.3 kWh/year home [42], and the thermal demand was 5233.21 kWh/year home [43] with a mean value of 2.5 persons per home [44]. The digestate derived from decentralized units was dewatered using a multi-disc screw-press sludge dehydrator. The digester location was assumed to be in the city extra-radius, assuming a multiplying factor of 4 to be applied to the distance marked by the city’s urban limits. The land application of digestates considered the transport of dewatered material (25% TS content) to a linear distance of 30 km, assuming a tortuosity factor of 1.4. The truck transport capacity was 40 t with a fuel consumption of 30 L diesel/100 km. The energy demand for digestate drying was estimated considering a value of 2270 kJ/kg as the heat of vaporization of water with a factor of 1.2 being used to consider difficulties in removing bound water. A 70% efficiency was assumed for the drying equipment. The LHV of digestate was between 15 and 18 MJ/kg [45,46,47].

3. Results

3.1. Analysis of Engine Performance

The electricity production was determined to be 1084.8 kW with 1056.6 kW of thermal power. This high efficiency was possible due to the large scale of the engine. Figure 3 shows the mass and energy balance of the engine and the double turbocharger at a 100% load. The reference temperature adopted was ambient conditions (25 °C) to evaluate two rows of cylinders. It should be noted that there was a mismatch of 20.6 kW in excess, which was 0.8% of the amount of energy brought into play at the starting point of the energy calculations. The thermal efficiency given by the manufacturer was 41.3%, which was equivalent to 1096.5 kW. This value differed from that obtained from the theoretical calculation with a difference of 39.8 kW (1.55% of the total energy contained in the biogas). This error may be explained by the fact that in the manufacturer’ real tests, there were conditions that the theoretical calculations did not consider, such as the use of cp−aire instead of that for the mixture (air–fuel) or that the average temperature of the flow between the inlet and outlet was used as the temperature for each stage. In any case, the difference was small enough to allow for predictions for electricity and thermal energy production.
The equations predicted a total efficiency for the engine of 80.4% (taking into account the 20.6 kW in excess), which was slightly higher than the value of 82.5% given by the manufacturer. The usable thermal power of the engine was 1314.5 kW and corresponded to that derived from both intercoolers, the oil exchangers, the block engine, and the exhaust gases (with a temperature of 142 °C). The useful thermal power was 1056.6 kW because the energy derived from intercooler 1 was disregarded due to its low temperature (<55 °C). The temperature of the exhaust gases was 142 °C. Any further energy recovery from this point was disregarded to avoid condensation problems. Thus, the energy recovery accounted for 423 kW. The energy flows of the main and auxiliary cooling circuits are shown in Figure 4. The adopted point of approximation between the exhaust air temperature and the inlet water was 5 °C for intercooler 1 and 10 °C for intercooler 2 [28].
The compression power of the first stage was 120.4 kW (35.9% of the total) because the inlet temperature of the mixture was 25 °C, the outlet temperature was 101.4 °C (+305.6%), and the compression ratio was 1.85. The compression power of the second stage was 214.7 kW (64.1%), which was more than 1.8 times that of the first one, as the inlet temperature of this second stage increased from 55 to 190.4 °C (+246.2%) and the compression ratio increased from 1.85 to 2.57 (+38.9%). The thermal power of each turbine stage was slightly higher than that of the compressor due to the mechanical losses occurring in the drive shafts (+3% in each stage). The density of the inlet mixture increased from 1.2 to 4.7 kg/m3 at the inlet of the cylinders (+291.6%). Therefore, the mass flow induced into the cylinders was almost four times higher, translating into a significant increase in efficiency.
The mean specific mechanical power per unit mass and displacement was 0.168 kW/kg, equivalent to 18.7 kW/L for single compression. These values increased to 0.199 kW/kg and 23.0 kW/L for double compression. The JGS 320 GS-BL engine with 1095 kW of mechanical power with dimensions of 5200 kg and 48.7 L would be equivalent to 6183 kg and 60.0 L for single compression. The mechanical efficiency when applying double compression was increased by 3.7% compared to that when applying single compression. The compression ratio was 4.2% higher for double compression, thus increasing the mechanical efficiency; the MEP was 23.3% higher for double compression. The double-compression engine allowed for a better energy recovery, thus justifying the centralized configuration when producing electricity from biogas. In addition, this type of engine allows for heat recovery, which is an important benefit for local populations.
The location of the engine close to the city area would facilitate the inhabitants benefitting from the extra thermal energy produced. If bonuses were distributed in the form of heat to the local population, they may be more receptive to the strategy of treating waste in a decentralized manner. However, an inconvenience appears in the form of supplying heat to several small digester units, requiring a new heat source to provide them with the thermal energy necessary to reach the operating temperatures.
Other technical alternatives that may be considered for valorizing biogas include upgrading biogas to reach the quality of natural gas, the use of fuel cells for electricity production, or the use of micro-turbines. In the first case, the technology has matured, and its feasibility should be carefully analyzed since profitability is very case-specific and is based on the availability of governmental subsidies [48]. The use of fuel cells and micro-turbines are promising options, but these technologies still face several challenges regarding biogas cleaning and installation costs [49,50,51]. There are currently several applications of high-efficiency CHP engines in wastewater treatment plants, landfills, and industry [52,53,54]. Biogas contains several contaminants that need to be removed, such as sulfur compounds, ammonia, small amounts of oxygen, and moisture [55,56]. CHP engines present lower cleaning requirements when compared with other valorization alternatives, thus making them the preferred gas valorization option.

3.2. Technical Feasibility of Decentralized Configuration

Considering the assumptions associated with waste production, the expected volumetric flow of material susceptible to co-digestion accounted for 294 ± 1 m3/d. The decentralized treatment of this material could be carried out in several homogenously distributed digesters in the city area. The HRT applied to the digestion process greatly influenced the size and number of digesters needed. Figure 5 shows the number of digestion units needed for treating this mixture. The minimum value of HRT evaluated was 15 days. Although this value may be feasible for treating food waste as a single substrate, its treatment with garden waste may cause an incomplete degradation due to the high lignocellulosic character of this latter material, which needs longer retention times [57].
Tian et al. [58] studied the decentralized digestion of wastes, reporting better results regarding global warming potential when evaluating the life cycle assessment of different treatment configurations. However, the treatment of this type of waste in a distributed form, when implemented in cities, implies having enough area susceptible to locating digesters and the auxiliary equipment associated with the grinding and mixing procedures for preparing the digester feed and, subsequently, when digestion ends, the auxiliary equipment necessary for digestate dewatering and storing this material until finding a final disposal option. The lower efficiency attained when comparing centralized and decentralized waste treatment systems should be noted, as demonstrated by González et al. [59] when evaluating the decentralized treatment of swine manure. Considering the minimum digester size at a lower HRT of 15 days, the use of the smallest digesters translates into an area of 2.65 hectares needed for locating the 88 small treatment plants, whereas this value increases to 7.06 hectares if the highest HRT is selected for the same working volume of reactors.
The location of these units would not be free of controversy. Locating a great number of digestion plants may not be free of generating odors and nuisance, although efforts could be made for covering equipment and avoiding adverse visual effects. Reducing offensive gaseous emissions and eliminating involuntary spills of fresh material would probably become an impossible task. These activities, when carried out close to residential areas, may cause rejection by neighbors. An attempt to install such types of units would probably cause the revival of the “not in my backyard” syndrome, which transforms into “not in anybody’s backyard”, no matter how useful the idea of locally treating waste may seem [60]. Locating such units in urban areas would also translate into a decrease in green areas. For the case examined here, if a value of 25 m2/inhab. is considered as the average value of available green area [61], then the decrease in these areas would be 0.7% in the best case, but it would rise to 1.9% when the highest HRT is considered. The question is how many neighbors would be willing to accept reducing their green areas for locating a permanent waste treatment facility in their vicinity, particularly considering that this decrease would not be evenly distributed and, therefore, some specific areas would suffer the main reduction.
There are several reports in the literature regarding the social rejection caused when planners try to locate different treatment centers that are needed in terms of the public interest but find a ferrous opposition when the specific location of the installation is to be set [62,63,64,65]. However, if the proximity of the location is not close enough so as to cause adverse effects to be experienced by residents but economic benefits could still be obtained in terms of jobs or energy bonuses, then a greater willingness to accept may be possible [66]. Locating these installations in the extra radius may be feasible since the population density in these areas is much lower. The most suitable option when taking any kind of decision regarding energy production or waste treatment must be based on different aspects such as technical, economic, environmental, and social criteria so as to comply with sustainable engineering principles [67].
The number of digesters needs to be set based on efficiency considerations. Thus, the volume and number of digestion units were estimated by considering the amount of thermal energy available. The volumetric flow of biogas expected was 482 ± 18 m3/h, a value estimated from SMP data. Considering the use of two engines, the gas loading would be 55.7 ± 2.1%, thus reducing the efficiency of electricity conversion and the thermal energy available. Figure 6a represents the thermal energy available for the two extreme values of digester configurations (under maximum and minimum retention times). The larger the hydraulic retention time, the less thermal energy is available for other uses because of the increased digester size and the thermal losses associated with the reactor surface. The blue band in this graph represents the range of available thermal energy under different thermal gradients at an HRT of 40 days. Similarly, the gray band represents the case for an HRT of 15 days. Clearly, the thermal energy available in this latter case is much greater, with a narrower band due to lower thermal losses experienced in winter because of the lower digester size.
The distribution presented in Figure 6a considers the number of digesters needed for each reactor size studied, which is represented in the x-axis. The amount of gas obtained penalized the engine performance since the efficiency was adversely affected by the lower loading of the engines. Thus, the electrical efficiency was reduced to 37.8%. The electricity available for daily activities would be scarcely enough to cover less than 1% (0.96 ± 0.05%) of the daily energy needs of a city of 150,000 inhab. In the case of thermal needs, the system could cover 2.5% of the city’s requirements in the summer period, when thermal losses are at a minimum, if assuming the implementation of the lowest HRT. However, in the winter period, almost all the thermal energy available would be necessary to maintain the system operating temperature when considering the lowest digester size.
The previous values may be improved by applying pretreatments that could increase the garden waste’s SMP. However, thermal and mechanical pretreatments increase the energy demand of the global process [68,69]. High temperatures usually accompany chemical pretreatments, such as using alkali or acid solutions, to become more effective, but costs and corrosive effects are disadvantages to be added [70,71]. Other pretreatments may be more beneficial in terms of energy demand and auxiliary equipment, such as micro-aerobic pretreatment or pre-acidification with digestate [72,73]. Adding small amounts of air to anaerobic systems can increase the methane production by up to 19% [74], while other studies have reported increases of up to three times [75]. If a modest 10% increase in methane production is assumed for yard wastes, then the benefits would translate into a coverage of 2.6% of the thermal needs of the city’s requirements in summer periods, a value also estimated by assuming the lowest retention time. A further increase of up to 40% would allow for loading the engines close to 73.4% of their maximum capacity, which would translate into higher values of efficiency in terms of electricity production and thermal recovery. Thus, 1.3% of the electricity demand could be covered by CHP engines, whereas a value of 3.2% could be obtained for covering the thermal needs, also under the same assumptions. Figure 6b shows the thermal energy range available under the latest assumption, and Figure 7 shows the results obtained from the Monte Carlo simulation.
The energy produced by CHP engines, whether in the form of electricity or thermal energy, may seem insufficient. However, these systems can be integrated into other renewable energy production systems in a hybrid scheme, thus reducing the dependence on fossil fuels. Investing in this type of energy can create jobs for local populations and promote sustainable development [76], favoring the decarbonization of the economy. The size of the single digesters needed for treating the daily mass of waste produced was 350 m3.
This size was selected because it was the value obtained after minimizing the available thermal energy changes with the digester size. Thus, the number of digesters needed would be 13 units. The location of the digesters in the community extra radius would be such that the zone selected would fall outside the city borders. For a population density of 2500 inhab./km2, the urban area would account for 60 km2. By increasing this area by a factor of four, the diameter of the circumference would be 17.5 km. Therefore, the digester would be located at a distance of 4.2 km from one another following the circumference perimeter. One factor that was not considered in the present estimation was the price of land. Some areas surrounding a city may have a higher land price due to specific landscape attributes, making them the living preference of high-income residents, thus adding constraints to the availability of suitable locations. The localization of a waste treatment plant will affect the price of land, probably reducing the value of the surrounding land, adversely affecting house pricing.
Previous estimations were carried out considering a solid content of the feed of 110 g/L. The increase in the solid content of the feed may increase productivity thanks to a better use of the digester volume [77]. Nevertheless, there is a limit to increasing the solid content in digestion systems, which is dictated by mass transfer restrictions and inhibitory compounds, significantly affecting methane yields [78,79]. Considering a value of 14% solid content prior to experiencing process adverse effects as a limit [80], the number of digesters would be reduced to 10 units, thus decreasing the impact caused by the presence of decentralized plants in the city surroundings.
The centralized valorization of biogas derived from several digesters also implies the development of a low-quality gas network for the transport of biogas to the high-efficiency engine location. Implementing this approach would translate into higher installation costs since compression units would be needed along with constructing a specific gas grid design for the underground transport of low-pressure gas. The carbon dioxide content in biogas sets limits to the pressure of the network. Therefore, a further analysis is necessary to evaluate the technical feasibility of this approach by considering additional auxiliary equipment linked to biogas compression and transport. Given the power input associated with the engine, the proposal is limited to a high flux of wastes or to a scenario of biogas co-valorization with other gases, such as natural gas or syngas derived from municipal solid wastes.

3.3. A Practical Solution Is Necessary to Finally Dispose of the Digestate

Anaerobic digestion is an eco-friendly technology with a low energy demand. However, the production of digestate as a by-product creates challenges that may not be easy to overcome. In the present case, the slurry produced daily was 60 t/d (TS content of 25%). The land application of this material is not feasible within city’s borders. Transport to the city’s outskirts is necessary for feasible agronomic application. Land spreading requires 0.5 TJ/year for digestate transport, which is the least energy-intensive option. The centralized composting of digestate reduces the material available for land spreading. Composting has been evaluated as a suitable way for valorizing digestate and increasing the quality of the organic material [81,82]. Mineralization attained during aerobic conversion reduces the volatile solid content and modifies the chemical characteristics of the organic matter [83,84]. However, the land requirements for a composting treatment plant are high, and the search for a market is necessary to attain the commercialization of the end product.
The thermal valorization of this material translates into an excessive energy demand because a drying operation is necessary prior to implementing an incineration or pyrolysis/gasification stage. The estimated amount of energy demanded if the digestate is to be dried up to a 90% TS content is 61.4 TJ/year. However, the amount of energy contained in the digestate ranges between 82 and 98.3 TJ/year, based on previous assumptions regarding LHVs. This implies that about 62–75% of the energy in the digestate is required for drying. The energetic valorization of this material does not seem suitable unless other benefits are obtained, such as the recycling of nutrients from combustion ashes. Thermal processes have high installation costs, so they are better suited to a large-scale scenario where the centralization of biomass treatment is the main aim [85,86,87].
Although there are several advantages to implementing waste treatment decentralization, the valorization of biogas and digested material performs better with a centralized configuration. The concept of decentralizing the treatment of organic wastes in high-density populated urban areas may seem irrational given all the difficulties that can be encountered regarding the location and the nuisance caused to neighbors. The centralized thermal treatment of digestate may show a better balance by combining it with other biomass and waste sources. Alternatives for valorization may consider its transformation into fuels and activated carbon [88,89]. However, these are highly energy-intensive processes more suited to a large-scale centralized configuration. Other alternatives, such as microalgae cultivation and media for bacterial growth, are promising options, but they are still at an infancy stage [90,91,92].

4. Conclusions

The advantages of decentralized waste treatment cannot be ignored. It offers the local processing of organics and reduces transport distances. However, for this configuration to work, technical details such as the number of digestion units required and the location of small treatment plants in city areas must be analyzed thoroughly. The production of electricity from biogas and the valorization of digestates are activities better suited to large-scale centralized configurations given the higher efficiency of these installations and the high costs. An essential factor to be considered when analyzing the decentralized treatment of wastes is the perception of the local population to this alternative and the possible nuisance caused, which may appear as a consequence of treating organic materials susceptible to producing odors and offensive emissions close to residential areas.
In the present document, the digestion of food and garden wastes was assumed to be locally treated in the city surroundings, needing 10 digesters for the best scenario and capable of producing enough electricity to cover 1.3% of the demand and 3.2% of the thermal needs (summer period) when using high-efficiency engines (double turbocharged). These results are a first approximation towards achieving sustainable cities, where resources and energy may be obtained from their own urban ecosystem.
However, the location of these small plants would not be free of controversy, probably making the whole treatment proposal unfeasible unless the local population enjoys tangible benefits. Decentralization is highly penalized by lower efficiencies due to the smaller scale of treatment units. Thus, a compensation mechanism should be available if this alternative is to be seriously considered as a feasible option for producing local resources from waste and integrating waste streams into the circular economy concept.
Future work will consider aspects regarding biogas upgrading and transport along with the feasibility of using a shared gas network for biogas and syngas derived from waste or biomass gasification.

Author Contributions

Conceptualization, J.G.-C. and X.G.; methodology, R.G. and J.G.-C.; validation, X.G., R.G. and J.G.-B.; formal analysis, R.G. and J.G.-B.; investigation, X.G.; resources, J.G.-C.; data curation, J.G.-B. and R.G.; writing—original draft preparation, J.G.-C.; writing—review and editing, X.G. and R.G.; visualization, J.G.-B.; supervision, X.G. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data are available on request to corresponding author.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Gadaleta, G.; De Gisi, S.; Notarnicola, M. Feasibility Analysis on the Adoption of Decentralized Anaerobic Co-Digestion for the Treatment of Municipal Organic Waste with Energy Recovery in Urban Districts of Metropolitan Areas. Int. J. Environ. Res. Public Health 2021, 18, 1820. [Google Scholar] [CrossRef]
  2. Nenciu, F.; Stanciulescu, I.; Vlad, H.; Gabur, A.; Turcu, O.L.; Apostol, T.; Vladut, V.N.; Cocarta, D.M.; Stan, C. Decentralized Processing Performance of Fruit and Vegetable Waste Discarded from Retail, Using an Automated Thermophilic Composting Technology. Sustainability 2022, 14, 2835. [Google Scholar] [CrossRef]
  3. González, R.; Hernández, J.E.; Gómez, X.; Smith, R.; González Arias, J.; Martínez, E.J.; Blanco, D. Performance evaluation of a small-scale digester for achieving decentralised management of waste. Waste Manag. 2020, 118, 99–109. [Google Scholar] [CrossRef] [PubMed]
  4. Wang, J. Decentralized Biogas Technology of Anaerobic Digestion and Farm Ecosystem: Opportunities and Challenges. Front. Energy Res. 2014, 2, 10. [Google Scholar] [CrossRef]
  5. Voegeli, Y.; Zurbrügg, C. Decentralised Anaerobic Digestion of Kitchen and Market Waste in Developing Countries—‘State of the Art’ in South India. In Proceedings of the Second International Symposium on Energy from Biomass and Waste, Venice, Italy, 17–20 November 2008. [Google Scholar]
  6. Raha, D.; Mahanta, P.; Clarke, M.L. The implementation of decentralised biogas plants in Assam, NE India: The impact and effectiveness of the National Biogas and Manure Management Programme. Energy Policy 2014, 68, 80–91. [Google Scholar] [CrossRef]
  7. Luo, T.; Khoshnevisan, B.; Huang, R.; Chen, Q.; Mei, Z.; Pan, J.; Liu, H. Analysis of revolution in decentralized biogas facilities caused by transition in Chinese rural areas. Renew. Sustain. Energy Rev. 2020, 133, 110133. [Google Scholar] [CrossRef]
  8. Samer, M.; Abdelaziz, S.; Refai, M.; Abdelsalam, E. Techno-economic assessment of dry fermentation in household biogas units through co-digestion of manure and agricultural crop residues in Egypt. Renew. Energy 2020, 149, 226–234. [Google Scholar] [CrossRef]
  9. Bruun, S.; Jensen, L.S.; Khanh Vu, V.T.; Sommer, S. Small-scale household biogas digesters: An option for global warming mitigation or a potential climate bomb? Renew. Sustain. Energy Rev. 2014, 33, 736–741. [Google Scholar] [CrossRef]
  10. Luo, T.; Zhu, N.; Shen, F.; Long, E.; Long, Y.; Chen, X.; Mei, Z. A Case Study Assessment of the Suitability of Small-Scale Biogas Plants to the Dispersed Agricultural Structure of China. Waste Biomass Valorization 2016, 7, 1131–1139. [Google Scholar] [CrossRef]
  11. Mench, J.A. Farm animal welfare in the U.S.A.: Farming practices, research, education, regulation, and assurance programs. Appl. Anim. Behav. Sci. 2008, 113, 298–312. [Google Scholar] [CrossRef]
  12. Hötzel, M.J. Improving farm animal welfare: Is evolution or revolution needed in production systems? In Dilemmas in Animal Welfare; CABI: Wallingford UK, 2023; pp. 67–84. [Google Scholar] [CrossRef]
  13. Wilkinson, K.G. A comparison of the drivers influencing adoption of on-farm anaerobic digestion in Germany and Australia. Biomass Bioenergy 2011, 35, 1613–1622. [Google Scholar] [CrossRef]
  14. O’Connor, S.; Ehimen, E.; Pillai, S.C.; Power, N.; Lyons, G.A.; Bartlett, J. An Investigation of the Potential Adoption of Anaerobic Digestion for Energy Production in Irish Farms. Environments 2021, 8, 8. [Google Scholar] [CrossRef]
  15. Velásquez Piñas, J.A.; Venturini, O.J.; Silva Lora, E.E.; del Olmo, O.A.; Calle Roalcaba, O.D. An economic holistic feasibility assessment of centralized and decentralized biogas plants with mono-digestion and co-digestion systems. Renew. Energy 2019, 139, 40–51. [Google Scholar] [CrossRef]
  16. González, R.; Blanco, D.; Cascallana, J.G.; Carrillo-Peña, D.; Gómez, X. Anaerobic Co-Digestion of Sheep Manure and Waste from a Potato Processing Factory: Techno-Economic Analysis. Fermentation 2021, 7, 235. [Google Scholar] [CrossRef]
  17. Imeni, S.M.; Puy, N.; Ovejero, J.; Busquets, A.M.; Bartroli, J.; Pelaz, L.; Ponsá, S.; Colón, J. Techno-Economic Assessment of Anaerobic Co-digestion of Cattle Manure and Wheat Straw (Raw and Pre-treated) at Small to Medium Dairy Cattle Farms. Waste Biomass Valorization 2020, 11, 4035–4051. [Google Scholar] [CrossRef]
  18. Fuldauer, L.I.; Parker, B.M.; Yaman, R.; Borrion, A. Managing anaerobic digestate from food waste in the urban environment: Evaluating the feasibility from an interdisciplinary perspective. J. Clean. Prod. 2018, 185, 929–940. [Google Scholar] [CrossRef]
  19. Babbitt, C.W. The role of clean technology research in creating sustainable urban food waste solutions. Clean Technol. Environ. Policy 2020, 22, 1–4. [Google Scholar] [CrossRef]
  20. Zhang, J.; Gu, D.; Chen, J.; He, Y.; Dai, Y.; Loh, K.-C.; Tong, Y.W. Assessment and optimization of a decentralized food-waste-to-energy system with anaerobic digestion and CHP for energy utilization. Energy Convers. Manag. 2021, 228, 113654. [Google Scholar] [CrossRef]
  21. Ellacuriaga, M.; González, R.; Gómez, X. Is Decentralized Anaerobic Digestion a Solution? Analyzing Biogas Production and Residential Energy Demand. Eng 2022, 3, 662–676. [Google Scholar] [CrossRef]
  22. Nguyen, H.H.; Heaven, S.; Banks, C. Energy potential from the anaerobic digestion of food waste in municipal solid waste stream of urban areas in Vietnam. Int. J. Energy Environ. Eng. 2014, 5, 365–374. [Google Scholar] [CrossRef]
  23. Miller, K.E.; Herman, T.; Philipinanto, D.A.; Davis, S.C. Anaerobic Digestion of Food Waste, Brewery Waste, and Agricultural Residues in an Off-Grid Continuous Reactor. Sustainability 2021, 13, 6509. [Google Scholar] [CrossRef]
  24. Win, S.S.; Hegde, S.; Chen, R.B.; Trabold, T.A. Feasibility Assessment of Low-Volume Anaerobic Digestion Systems for Institutional Food Waste Producers. In Energy Sustainability; American Society of Mechanical Engineers: New York, NY, USA, 2017; Volume 57595, p. V001T02A003. [Google Scholar] [CrossRef]
  25. García-Cascallana, J.; Carrillo-Peña, D.; Morán, A.; Smith, R.; Gómez, X. Energy Balance of Turbocharged Engines Operating in a WWTP with Thermal Hydrolysis. Co-Digestion Provides the Full Plant Energy Demand. Appl. Sci. 2021, 11, 11103. [Google Scholar] [CrossRef]
  26. Jenbacher. Jenbacher Type 3 Gas Engine. Available online: https://www.clarke-energy.com/gas-engines/type-3-gas-engines/ (accessed on 10 January 2023).
  27. ISO/3046/1; Reciprocating Internal Combustion Engines—Performance—Part 1: Declarations of Power, Fuel and Lubricating Oil Consumptions, and Test Methods—Additional Requirements for Engines for General Use. ISO: Geneva, Switzerland, 2002.
  28. Jenbacher. Technical Description Genset JGS 320 GS B L. AB Energy 320-18. Available online: https://www.energy-motors.com/sites/default/files/ge_jenbacher_j320.pdf (accessed on 10 January 2023).
  29. Honeywell: Garret Performance Engine Parts Catalogue, Volume 6. Available online: https://images.carid.com/garrett/items/pdf/garrett-product-catalog.pdf (accessed on 15 January 2023).
  30. The Engineering Toolbox. Available online: https://www.engineeringtoolbox.com/individual-universal-gas-constant-d_588.html (accessed on 15 January 2023).
  31. Urieli, I. Specific Heat Capacities of Air. Available online: https://www.ohio.edu/mechanical/thermo/property_tables/air/air_Cp_Cv.html (accessed on 15 January 2023).
  32. Abu-Nada, E.; Al-Hinti, I.; Al-Sarkhi, A.; Akash, B. Thermodynamic modeling of spark-ignition engine: Effect of temperature dependent specific heats. Int. Commun. Heat Mass Transf. 2006, 33, 1264–1272. [Google Scholar] [CrossRef]
  33. UNEP: Annual per Capita Household Food Waste of Selected Countries Worldwide as of 2020. Available online: https://www.statista.com/statistics/933059/per-capita-food-waste-of-selected-countries/ (accessed on 10 February 2023).
  34. Manu, M.K.; Kumar, R.; Garg, A. Physical and chemical characterization of yard waste. Int. J. Appl. Eng. Res. 2013, 8, 1891–1896. [Google Scholar]
  35. Redondas, V.; Moran, A.; Martínez, J.E.; Fierro, J.; Gomez, X. Effect of methanogenic effluent recycling on continuous H2 production from food waste. Environ. Prog. Sustain. Energy 2015, 34, 227–233. [Google Scholar] [CrossRef]
  36. Odejobi, O.J.; Ajala, O.O.; Osuolale, F.N. Anaerobic co-digestion of kitchen waste and animal manure: A review of operating parameters, inhibiting factors, and pretreatment with their impact on process performance. Biomass Convers. Biorefinery 2023, 13, 5515–5531. [Google Scholar] [CrossRef]
  37. Helenas Perin, J.K.; Biesdorf Borth, P.L.; Torrecilhas, A.R.; Santana da Cunha, L.; Kuroda, E.K.; Fernandes, F. Optimization of methane production parameters during anaerobic co-digestion of food waste and garden waste. J. Clean. Prod. 2020, 272, 123130. [Google Scholar] [CrossRef]
  38. Gómez, X.; Cuetos, M.J.; Tartakovsky, B.; Martínez-Núñez, M.F.; Morán, A. A comparison of analytical techniques for evaluating food waste degradation by anaerobic digestion. Bioprocess Biosyst. Eng. 2010, 33, 427–438. [Google Scholar] [CrossRef]
  39. González, R.; Rosas, J.G.; Blanco, D.; Smith, R.; Martínez, E.J.; Pastor-Bueis, R.; Gómez, X. Anaerobic digestion of fourth range fruit and vegetable products: Comparison of three different scenarios for its valorisation by life cycle assessment and life cycle costing. Environ. Monit. Assess. 2020, 192, 551. [Google Scholar] [CrossRef]
  40. Panigrahi, S.; Sharma, H.B.; Dubey, B.K. Overcoming yard waste recalcitrance through four different liquid hot water pretreatment techniques—Structural evolution, biogas production and energy balance. Biomass Bioenergy 2019, 127, 105268. [Google Scholar] [CrossRef]
  41. Favoino, E.; Giavini, M. Bio-Waste Generation in the EU: Current Capture Levels and Future Potential. Available online: https://zerowasteeurope.eu/wp-content/uploads/2020/07/2020_07_06_bic_zwe_report_bio_waste.pdf (accessed on 10 February 2023).
  42. Expansion: España—Consumo de Electricidad. Available online: https://datosmacro.expansion.com/energia-y-medio-ambiente/electricidad-consumo/espana (accessed on 10 February 2023).
  43. IDAE: Consumo Por Usos Del Sector Residencial. Available online: https://informesweb.idae.es/consumo-usos-residencial/informe.php (accessed on 10 February 2023).
  44. INE: Promedio De Personas En Los Hogares De España En 2020, Según Comunidad Autónoma [Gráfica]. Available online: https://es.statista.com/estadisticas/1013728/promedio-de-personas-en-los-hogares-en-espana-segun-comunidad-autonoma/#:~:text=TamañomediodelhogarsegúnCC.&text=EnelconjuntodeEspaña,2%2C5personasporhogar (accessed on 10 February 2023).
  45. Otero, M.; Sánchez, M.E.; Gómez, X. Co-firing of coal and manure biomass: A TG–MS approach. Bioresour. Technol. 2011, 102, 8304–8309. [Google Scholar] [CrossRef]
  46. Freda, C.; Nanna, F.; Villone, A.; Barisano, D.; Brandani, S.; Cornacchia, G. Air gasification of digestate and its co-gasification with residual biomass in a pilot scale rotary kiln. Int. J. Energy Environ. Eng. 2019, 10, 335–346. [Google Scholar] [CrossRef]
  47. Czekała, W. Solid Fraction of Digestate from Biogas Plant as a Material for Pellets Production. Energies 2021, 14, 5034. [Google Scholar] [CrossRef]
  48. Kapoor, R.; Ghosh, P.; Kumar, M.; Vijay, V.K. Evaluation of biogas upgrading technologies and future perspectives: A review. Environ. Sci. Pollut. Res. 2019, 26, 11631–11661. [Google Scholar] [CrossRef]
  49. Tawalbeh, M.; Alarab, S.; Al-Othman, A.; Javed, R.M.N. The operating parameters, structural composition, and fuel sustainability aspects of PEM fuel cells: A mini review. Fuels 2022, 3, 449–474. [Google Scholar] [CrossRef]
  50. Kabeyi, M.J.B.; Olanrewaju, O.A. Technologies for biogas to electricity conversion. Energy Rep. 2022, 8, 774–786. [Google Scholar] [CrossRef]
  51. Prioriello, A.; Duranti, L.; Luisetto, I.; Sanna, F.; Larosa, C.; Grilli, M.L.; Di Bartolomeo, E. Structured Catalyst for Indirect Internal Reforming (IIR) of Biogas in Solid Oxide Fuel Cell (SOFC). Catalysts 2023, 13, 1129. [Google Scholar] [CrossRef]
  52. Available online: https://www.innio.com/es/productos/jenbacher (accessed on 14 August 2023).
  53. Available online: https://www.idom.com/proyecto/central-electrica-a-partir-de-gas-de-vertedero-de-valdemingomez-19-mw/ (accessed on 14 August 2023).
  54. Available online: https://ecogen.be/en/projects/ (accessed on 14 August 2023).
  55. Upadhyay, A.; Kovalev, A.A.; Zhuravleva, E.A.; Kovalev, D.A.; Litti, Y.V.; Masakapalli, S.K.; Pareek, N.; Vivekanand, V. Recent Development in Physical, Chemical, Biological and Hybrid Biogas Upgradation Techniques. Sustainability 2022, 15, 476. [Google Scholar] [CrossRef]
  56. Secco, C.; Fuziki, M.E.K.; Tusset, A.M.; Lenzi, G.G. Reactive Processes for H2S Removal. Energies 2023, 16, 1759. [Google Scholar] [CrossRef]
  57. González, R.; Peña, D.C.; Gómez, X. Anaerobic Co-Digestion of Wastes: Reviewing Current Status and Approaches for Enhancing Biogas Production. Appl. Sci. 2022, 12, 8884. [Google Scholar] [CrossRef]
  58. Tian, H.; Wang, X.; Lim, E.Y.; Lee, J.T.E.; Ee, A.W.L.; Zhang, J.; Tong, Y.W. Life cycle assessment of food waste to energy and resources: Centralized and decentralized anaerobic digestion with different downstream biogas utilization. Renew. Sustain. Energy Rev. 2021, 150, 111489. [Google Scholar] [CrossRef]
  59. González, R.; García-Cascallana, J.; Gómez, X. Energetic valorization of biogas. A comparison between centralized and decentralized approach. Renew. Energy 2023, 119013. [Google Scholar] [CrossRef]
  60. Heiman, M. From ‘Not in My Backyard!’ to ‘Not in Anybody’s Backyard!’. J. Am. Plan. Assoc. 1990, 56, 359–362. [Google Scholar] [CrossRef]
  61. Diario de León: Las Ciudades de Castilla y León Disponen de 22,54 Metros Cuadrados de Zona Verde Por Habitante. Available online: https://ileon.eldiario.es/actualidad/ciudades-castilla-leon-disponen-metros-cuadrados-zona-verde-habitante_1_9449713.html#:~:text=León-ciudad-cuenta-con-el,superficie-urbana-catalogada-como-verde (accessed on 10 May 2023).
  62. Peelle, E.; Ellis, R. Beyond the not-in-my-backyard impasse. Forum Appl. Res. Publ. Pol. 1987, 2. Available online: https://www.osti.gov/biblio/6055189 (accessed on 10 May 2023).
  63. Xu, M.; Lin, B. Exploring the “not in my backyard” effect in the construction of waste incineration power plants—Based on a survey in metropolises of China. Environ. Impact Assess. Rev. 2020, 82, 106377. [Google Scholar] [CrossRef]
  64. Nie, Y.; Zhao, J.; Zhang, Y.; Zhou, J. Risk Evaluation of “Not-In-My-Back-Yard” Conflict Potential in Facilities Group: A Case Study of Chemical Park in Xuwei New District, China. Sustainability 2020, 12, 2723. [Google Scholar] [CrossRef]
  65. He, L.; Yang, Q.; Liu, X.; Fu, L.; Wang, J. Exploring Factors Influencing Scenarios Evolution of Waste NIMBY Crisis: Analysis of Typical Cases in China. Int. J. Environ. Res. Public Health 2021, 18, 2006. [Google Scholar] [CrossRef]
  66. Guo, Y.; Ru, P.; Su, J.; Anadon, L.D. Not in my backyard, but not far away from me: Local acceptance of wind power in China. Energy 2015, 82, 722–733. [Google Scholar] [CrossRef]
  67. Štilić, A.; Puška, A. Integrating Multi-Criteria Decision-Making Methods with Sustainable Engineering: A Comprehensive Review of Current Practices. Eng 2023, 4, 1536–1549. [Google Scholar] [CrossRef]
  68. Herrmann, C.; Heiermann, M.; Idler, C.; Prochnow, A. Particle Size Reduction during Harvesting of Crop Feedstock for Biogas Production I: Effects on Ensiling Process and Methane Yields. Bioenergy Res. 2012, 5, 926–936. [Google Scholar] [CrossRef]
  69. García-Cascallana, J.; Barrios, X.G.; Martinez, E.J. Thermal Hydrolysis of Sewage Sludge: A Case Study of a WWTP in Burgos, Spain. Appl. Sci. 2021, 11, 964. [Google Scholar] [CrossRef]
  70. Zheng, M.; Li, X.; Li, L.; Yang, X.; He, Y. Enhancing anaerobic biogasification of corn stover through wet state NaOH pretreatment. Bioresour. Technol. 2009, 100, 5140–5145. [Google Scholar] [CrossRef] [PubMed]
  71. Kim, D.; Kim, J.; Lee, C. Effect of Mild-Temperature Thermo-Alkaline Pretreatment on the Solubilization and Anaerobic Digestion of Spent Coffee Grounds. Energies 2018, 11, 865. [Google Scholar] [CrossRef]
  72. Amin, F.R.; Khalid, H.; Zhang, H.; Rahman, S.U.; Zhang, R.; Liu, G.; Chen, C. Pretreatment methods of lignocellulosic biomass for anaerobic digestion. AMB Express 2017, 7, 72. [Google Scholar] [CrossRef]
  73. Zhang, L.; Loh, K.-C.; Zhang, J. Food waste enhanced anaerobic digestion of biologically pretreated yard waste: Analysis of cellulose crystallinity and microbial communities. Waste Manag. 2018, 79, 109–119. [Google Scholar] [CrossRef]
  74. Morello, R.; Di Capua, F.; Pontoni, L.; Papirio, S.; Spasiano, D.; Fratino, U.; Pirozzi, F.; Esposito, G. Microaerobic Digestion of Low-Biodegradable Sewage Sludge: Effect of Air Dosing in Batch Reactors. Sustainability 2021, 13, 9869. [Google Scholar] [CrossRef]
  75. Montalvo, S.; Huiliñir, C.; Ojeda, F.; Castillo, A.; Lillo, L.; Guerrero, L. Microaerobic pretreatment of sewage sludge: Effect of air flow rate, pretreatment time and temperature on the aerobic process and methane generation. Int. Biodeterior. Biodegrad. 2016, 110, 1–7. [Google Scholar] [CrossRef]
  76. León Gómez, J.C.; De León Aldaco, S.E.; Aguayo Alquicira, J. A Review of Hybrid Renewable Energy Systems: Architectures, Battery Systems, and Optimization Techniques. Eng 2023, 4, 1446–1467. [Google Scholar] [CrossRef]
  77. Ellacuriaga, M.; Cascallana, J.G.; González, R.; Gómez, X. High-Solid Anaerobic Digestion: Reviewing Strategies for Increasing Reactor Performance. Environments 2021, 8, 80. [Google Scholar] [CrossRef]
  78. Abbassi-Guendouz, A.; Brockmann, D.; Trably, E.; Dumas, C.; Delgenès, J.-P.; Steyer, J.-P.; Escudié, R. Total solids content drives high solid anaerobic digestion via mass transfer limitation. Bioresour. Technol. 2012, 111, 55–61. [Google Scholar] [CrossRef]
  79. Pastor-Poquet, V.; Papirio, S.; Trably, E.; Rintala, J.; Escudié, R.; Esposito, G. High-solids anaerobic digestion requires a trade-off between total solids, inoculum-to-substrate ratio and ammonia inhibition. Int. J. Environ. Sci. Technol. 2019, 16, 7011–7024. [Google Scholar] [CrossRef]
  80. Jansson, A.T.; Patinvoh, R.J.; Sárvári Horváth, I.; Taherzadeh, M.J. Dry Anaerobic Digestion of Food and Paper Industry Wastes at Different Solid Contents. Fermentation 2019, 5, 40. [Google Scholar] [CrossRef]
  81. González, R.; Ellacuriaga, M.; Aguilar-Pesantes, A.; Carrillo-Peña, D.; García-Cascallana, J.; Smith, R.; Gómez, X. Feasibility of Coupling Anaerobic Digestion and Hydrothermal Carbonization: Analyzing Thermal Demand. Appl. Sci. 2021, 11, 11660. [Google Scholar] [CrossRef]
  82. Casini, D.; Barsali, T.; Rizzo, A.M.; Chiaramonti, D. Production and characterization of co-composted biochar and digestate from biomass anaerobic digestion. Biomass Convers. Biorefinery 2021, 11, 2271–2279. [Google Scholar] [CrossRef]
  83. Gómez, X.; Diaz, M.C.; Cooper, M.; Blanco, D.; Morán, A.; Snape, C.E. Study of biological stabilization processes of cattle and poultry manure by thermogravimetric analysis and 13C NMR. Chemosphere 2007, 68, 1889–1897. [Google Scholar] [CrossRef] [PubMed]
  84. Núñez, F.; Pérez, M.; Leon-Fernández, L.F.; García-Morales, J.L.; Fernández-Morales, F.J. Effect of the mixing ratio on the composting of OFMSW digestate: Assessment of compost quality. J. Mater. Cycles Waste Manag. 2022, 24, 1818–1831. [Google Scholar] [CrossRef]
  85. Alzate, S.; Restrepo-Cuestas, B.; Jaramillo-Duque, Á. Municipal Solid Waste as a Source of Electric Power Generation in Colombia: A Techno-Economic Evaluation under Different Scenarios. Resources 2019, 8, 51. [Google Scholar] [CrossRef]
  86. Nubi, O.; Morse, S.; Murphy, R.J. Prospective Life Cycle Costing of Electricity Generation from Municipal Solid Waste in Nigeria. Sustainability 2022, 14, 13293. [Google Scholar] [CrossRef]
  87. Safarian, S.; Unnthorsson, R.; Richter, C. Techno-Economic and Environmental Assessment of Power Supply Chain by Using Waste Biomass Gasification in Iceland. Biophys. Econ. Sustain. 2020, 5, 7. [Google Scholar] [CrossRef]
  88. Wang, W.; Lee, D.-J. Valorization of anaerobic digestion digestate: A prospect review. Bioresour. Technol. 2021, 323, 124626. [Google Scholar] [CrossRef]
  89. Cesaro, A. The valorization of the anaerobic digestate from the organic fractions of municipal solid waste: Challenges and perspectives. J. Environ. Manag. 2021, 280, 111742. [Google Scholar] [CrossRef]
  90. Dębowski, M.; Zieliński, M.; Kisielewska, M.; Kazimierowicz, J.; Dudek, M.; Świca, I.; Rudnicka, A. The Cultivation of Lipid-Rich Microalgae Biomass as Anaerobic Digestate Valorization Technology—A Pilot-Scale Study. Processes 2020, 8, 517. [Google Scholar] [CrossRef]
  91. Ermis, H.; Güven-Gülhan, Ü.; Çakır, T.; Altınbaş, M. Microalgae growth and diversity in anaerobic digestate compared to synthetic media. Biofuel Res. J. 2022, 9, 1551–1556. [Google Scholar] [CrossRef]
  92. Pastor-Bueis, R.; Mulas, R.; Gómez, X.; González-Andrés, F. Innovative liquid formulation of digestates for producing a biofertilizer based on Bacillus siamensis: Field testing on sweet pepper. J. Plant Nutr. Soil Sci. 2017, 180, 748–758. [Google Scholar] [CrossRef]
Figure 1. Engine cooling system. This system was composed of two separate lines: the main and auxiliary circuit.
Figure 1. Engine cooling system. This system was composed of two separate lines: the main and auxiliary circuit.
Eng 04 00127 g001
Figure 2. General operating diagram of the biogas engine.
Figure 2. General operating diagram of the biogas engine.
Eng 04 00127 g002
Figure 3. Mass and energy balance of engine and double turbocharging (total of two symmetrical lines).
Figure 3. Mass and energy balance of engine and double turbocharging (total of two symmetrical lines).
Eng 04 00127 g003
Figure 4. Schemes of engine auxiliary and main cooling circuit. Results obtained from mass and energy balance.
Figure 4. Schemes of engine auxiliary and main cooling circuit. Results obtained from mass and energy balance.
Eng 04 00127 g004
Figure 5. Number of digesters needed for treating daily food and garden waste production for a hypothetical city of 150,000 inhabitants.
Figure 5. Number of digesters needed for treating daily food and garden waste production for a hypothetical city of 150,000 inhabitants.
Eng 04 00127 g005
Figure 6. (a) Available thermal energy obtained for digestion units of different sizes. (b) Estimation of available thermal energy if pretreatment of yard waste is assumed, attaining an SMP improvement of 40%.
Figure 6. (a) Available thermal energy obtained for digestion units of different sizes. (b) Estimation of available thermal energy if pretreatment of yard waste is assumed, attaining an SMP improvement of 40%.
Eng 04 00127 g006
Figure 7. Results obtained from the Monte Carlo simulation, assuming normal distribution for data input.
Figure 7. Results obtained from the Monte Carlo simulation, assuming normal distribution for data input.
Eng 04 00127 g007
Table 1. Geometric parameters of the JGS 320 GS-BL engine [26].
Table 1. Geometric parameters of the JGS 320 GS-BL engine [26].
Parameters of Engine Type J 320 GS-D121Value
Engine strokes (strokes/cycle)4
Total displacement (cm3)48,670
Number of cylinders (units)20 in V
Number of cylinder lines (units)2
Angle of the cylinders (°)70
B, bore (mm)135
S, stroke (mm)170
S/B, stroke/bore ratio1.26
rC, engine compression ratio (dimensionless)11.8
n, engine rotation speed (rpm)1500
Average piston speed (m/s)8.5
Piston displacement (L)2.43
Piston area (cm2)143
Combustion chamber volume (cm3)225
Combustion chamber/displacement ratio (%)6.8
Table 2. Performance characteristics of the JGS 320 GS-BL engine [28].
Table 2. Performance characteristics of the JGS 320 GS-BL engine [28].
Performance Parameters of Engine Type J 320 GS-D121Degree of Loading (%)
1007550
Minimum LHV 1 of biogas (kWh/m3)5
2 CH4 number/minimum CH4 number135/100
Peng, engine mechanical power (kW)1095821548
Electrical power (cos φ = 1) (kW)1067798529
MEP, mean effective pressure (kPa)18001350901
Radiation power losses (kW)54
Mechanical power losses (kW)282319
Power loss of exhaust gases (100 °C) (kW)685
Power loss of exhaust gases (180 °C) (kW)550
Power loss of exhaust gases (0 °C) (kW)740
Exhaust gas temperature (°C)490
Mair, air mass flow inlet (kg/h)5176
Meg, exhaust gas mass flow (wet) (kg/h)5634
Mbio, biogas mass flow (kg/h)458
ηmec, mechanical efficiency (%)41.240.138.2
Electrical efficiency (cos φ = 1) (%)40.23936.8
ηe, engine thermal efficiency (%)41.3
Energy efficiency (%)82.5
BC, biogas consumption (kW)265520461436
Min–max biogas pressure range at the biogas inlet train (mbar)80–200
Main circuit thermal power (kW)645519394
Block and jacket circuit power (kW)341336296
PINT-2, intercooler 2 power (kW)181785
Oil exchanger power (kW)12310593
Auxiliary circuit thermal power (kW)775838
PINT-1, intercooler 1 power (kW)775838
F, ratio fuel/air (%)8.8
Max. admissible exhaust back pressure after engine (kPa)6
Max. admissible pressure drop in front of intake-air filter (kPa)1
1 LHV: lower heating value. 2 Methane number is a measure of resistance to detonation. Pure methane had an assigned value of 100, and hydrogen had a value of 0.
Table 3. Turbochargers characteristics and operating parameters.
Table 3. Turbochargers characteristics and operating parameters.
Turbocharger ParametersValueReferences
Maximum temperature of the mixture at second intercooler (°C)83.9[26]
Maximum temperature of mixture at first intercooler (°C)55[26]
ηmec1, ηmec2, mechanical efficiency of turbocharger transmission97[29]
R, universal constant of ideal gas (J/kg K)287.05[30]
γ, adiabatic coefficient of air, mixture and gases (dimensionless)1.4[31]
Table 4. Assumptions for food and garden waste: solid content and specific methane production (SMP). TS: total solids, %VS: percentage of volatile solids.
Table 4. Assumptions for food and garden waste: solid content and specific methane production (SMP). TS: total solids, %VS: percentage of volatile solids.
ParameterFood WasteReferenceGarden WasteReferences
Production (kg/year per capita)77[33]110 1
TS content (g/kg)150 610[34]
%VS90[35,36]77.5 2[34,37]
SMP (mL CH4/g VS)340[38,39]257[40]
1 Estimated as the difference between the mixture of food waste and garden waste production by subtracting the amount of food waste produced. Mixture of food waste and garden waste for Spain was 187 kg/person year [41]. 2 Estimated as average values of those reported in references.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

González, R.; García-Cascallana, J.; Gutiérrez-Bravo, J.; Gómez, X. Decentralized Biogas Production in Urban Areas: Studying the Feasibility of Using High-Efficiency Engines. Eng 2023, 4, 2204-2225. https://doi.org/10.3390/eng4030127

AMA Style

González R, García-Cascallana J, Gutiérrez-Bravo J, Gómez X. Decentralized Biogas Production in Urban Areas: Studying the Feasibility of Using High-Efficiency Engines. Eng. 2023; 4(3):2204-2225. https://doi.org/10.3390/eng4030127

Chicago/Turabian Style

González, Rubén, José García-Cascallana, Javier Gutiérrez-Bravo, and Xiomar Gómez. 2023. "Decentralized Biogas Production in Urban Areas: Studying the Feasibility of Using High-Efficiency Engines" Eng 4, no. 3: 2204-2225. https://doi.org/10.3390/eng4030127