Article

Comparison of Kinetic Models Applied for Transport Description in Polymer Inclusion Membranes

by
Piotr Szczepański
Faculty of Chemistry, Nicolaus Copernicus University, 7 Gagarina Street, 87-100 Toruń, Poland
Membranes 2023, 13(2), 236; https://doi.org/10.3390/membranes13020236
Submission received: 20 December 2022 / Revised: 28 January 2023 / Accepted: 14 February 2023 / Published: 16 February 2023
(This article belongs to the Special Issue Polymer Inclusion Membranes: Analytical Applications)

Abstract

:
Five mathematical models for transport description in polymer inclusion membranes (PIMs) were presented and compared via regression analysis. The applicability of the models was estimated through the examination of experimental data of Zn(II), Cd(II), Pb(II), and Cu(II) ions transported by typical carriers. In four kinetic models, a change in the feed and stripping solution volume was taken into account. The goodness of fit was compared using the standard error of the regression, Akaike information criterion (AIC), Bayesian (Schwarz) information criterion (BIC), and Hannan–Quinn information criterion (HQC). The randomness distribution in the data was confirmed via a nonparametric runs test. Based on these quantities, appropriate models were selected.

1. Introduction

In past decades, polymer inclusion membranes (PIMs) have been frequently used in analytical applications. PIMs are employed to separate and preconcentrate various species such as metals, organics, and pharmaceutical compounds [1,2,3,4,5]. Their use in analytics requires the development of quantitative descriptions of the transport kinetics, which can be obtained through mathematical modeling. Appropriate equations can be used for the calculation of time-dependent values of, for example, the selectivity, concentration, or recovery factors, since an accurate prediction of these quantities is important in analytics, especially in the procedures of sample preparation [6].
For many years, simple mathematical models similar to those describing the reaction kinetics have been used to describe transport in many membrane systems. These equations have been primarily applied for describing transport in liquid membrane (LM) and PIM systems. As their main advantage, they enable the calculation of the parameters that influence transport efficiency (e.g., maximum flux) and predict concentration changes in respective solutions of the adjacent membrane solutions.

1.1. Model No. 1

Despite the availability of many different kinetic equations, one of the most commonly employed mathematical models is that proposed by Danesi [7], whose mathematical form is identical to the differential equations describing the kinetics of first-order reactions:
d c f d t = k 1 c f
d c s d t = V f V s k 1 c f
and results from the general transport scheme in the form of
c f k 1 c s
where k1 denotes the apparent first-order constant for membrane entrance, Vf and Vs are the volumes of the feed and receiving phase, and cf and cs are the concentrations of a substance at the given time t in the feed and the receiving solution, respectively.
The calculated k1 values can be further used for the evaluation of the permeability coefficient (P1, [cm/s]):
P 1 = k 1 V f A
as well as the initial maximum flux (JM, [mol/cm2·s]), because for the initial condition t = 0 and cf = cf,t = 0, it can be estimated from the well-known relationship [7]
J M = V f A d c f d t = P 1 c f , t = 0
In the above equations, A denotes the membrane surface area [cm2]. This simple model, as represented by Equations (1) and (2), is most frequently used to describe transport kinetics in PIMs. For example, only last year, it was used to describe the removal of fluoride [8] and phenol [9], the separation of mercury(II) [10], the separation of lithium and magnesium [11,12], the recovery of bismuth(III) [13] and scandium [14], the extraction of arsenic(V) [15], the separation of Pb(II), Zn(II), and Cd(II) ions [16], and the removal of antibiotics [17].
Noteworthy is the fact that, in some cases, the model fit quality is poor [15,17] or does not satisfy the criterion of a random distribution of residuals [10,16]. This means that a different or more advanced model should be used to describe the transport kinetics.

1.2. Model No. 2

It was previously shown that the transport of Cd(II), Zn(II), Pb(II), and Cu(II) ions through PIMs containing reactive ionic liquids or D2EHPA (di-(2-ethylhexyl)phosphoric acid) as a carrier obeys the kinetic laws of a reversible first-order reaction [18,19]:
c f k 1 k 1 c s
According to the general transport scheme above, the rate of change in concentrations in the respective solutions during the membrane transport can be expressed by
d c f d t = k 1 c f + V s V f k 1 c s
d c s d t = V f V s k 1 c f k 1 c s
This model was also successfully applied for the description of Pb(II) ion transport through PIMs containing calixresorcin [4] arene derivatives as carriers [20].

1.3. Model No. 3

In the models presented above, the initial maximum flux can be interpreted as a flux related to the sorption of molecules into the membrane. In this case, the value of the initial flux into the receiving phase has no physical meaning because in membrane processes controlled by diffusion, a time lag should be expected. This means that the minimum period of time is needed for the formation of the complex and its penetration into the membrane interior until the release of the first molecules into the receiving phase. At the beginning of the process, the zero value of the transported substance flux into the receiving solution should be expected if the membrane has not been pre-equilibrated with the feed solution. The application of effective carriers and the appropriate membrane composition allow for minimizing the time lag effect to such an extent that it is not observable in the process. However, in order to describe transport through PIMs, considering the diffusive nature of the process, the time lag should be taken into account, as it is always present in this type of system. For this purpose, a model whose equations are similar to the equations describing the kinetics of first-order consecutive reactions can be used:
c f k 1 c L M k 2 c s
d c f d t = k 1 c f
d c L M d t = V f V L M k 1 c f k 2 c L M
d c s d t = V L M V s k 2 c L M
Such a mathematical model is mainly applied for the description of the transport of various substances through bulk liquid membranes (BLMs). For instance, this model was applied in the case of the pertraction of chromium(VI) [21,22], chromium(III) [23], chromium(II) [24], mercury(II) [25], cobalt(II) [26], cadmium (II) [27], and cyanide and thiocyanate ions [28,29].

1.4. Model No. 4

Analogous to the model proposed by Danesi [7], in this model, a problem with its fitting to experimental data, as well as the related incorrect residual distribution, is observed [21,23,28]. The quality of the model fit can be improved by applying a model similar to a consecutive reaction scheme with a slow reversible step, antecedent to the irreversible step, according to the scheme
c f k 1 k 1 c L M k 2 c s
which can be described by the following set of differential equations:
d c f d t = k 1 c f + V L M V f k 1 c L M
d c L M d t = V f V L M k 1 c f k 1 c L M k 2 c L M
d c s d t = V L M V s k 2 c L M
This model was previously applied for the description of phenol [30], L-isoleucine [31], and strontium(II) pertraction [32] through BLMs.
In summary, there are at least four simple kinetic models that can be used to describe transport through PIMs. Nevertheless, only the model proposed by Danesi [7] is most frequently applied.

1.5. Model No. 5

It should be noted that in the case of the linear concentration vs. time dependence for transported substances, an equation similar to those describing a zero-order reaction (which corresponds to stationary or pseudo-stationary conditions of the transport) can be used:
d c f d t = k 1
Despite the many different kinetic models that enable the determination of the initial maximum flux (JM) and a quantitative description of the concentration change in the feed and receiving solutions, some authors calculate JM from the first derivative of an exponential decay function fitted to the feed solution concentration dependence [33,34,35,36,37]. This approach probably results from problems occurring when fitting the most commonly used kinetic model (model No. 2) to the experimental data. The calculated JM value describes the system efficiency. However, it is impossible to obtain a quantitative description of time-dependent concentrations, especially in the receiving solution. In this case, there is also no possibility of a physicochemical interpretation of the exponential decay function, contrary to the typical kinetic models. The main aim of this work is, therefore, to discuss the applicability of the above simple kinetic models and to select the most appropriate model for the transport description of substances through PIMs. The usefulness of the models was evaluated with the use of typical parameters describing the quality of the model fit to the experimental results of Zn(II), Cd(II), Pb(II), and Cu(II) ion transport. In the model calculations, a change in the feed and stripping solution volume (because of sampling) was taken into account. The goodness-of-fit evaluation was estimated using the standard error of the regression, Akaike information criterion (AIC), Bayesian (Schwarz) information criterion (BIC), and Hannan–Quinn information criterion (HQC). A nonparametric runs test was also used to examine the randomness of the residuals.
The novelty of this research is the development of a method for the selection of a proper model based on appropriate fit quality parameters and a runs test as well as the application of kinetic models that have never been used for the description of transport through PIMs.

2. Experimental

Experimental studies of Zn, Cd, Pb, and Cu ion transport through PIMs containing various types of carriers were carried out. The following carriers were used for this purpose: TOPO (tri-n-octyl phosphine oxide, 90% Sigma Aldrich, St. Louis, MO, USA), D2EHPA (di-(2-ethylhexyl) phosphoric acid, 97% Aldrich, St. Louis, USA), Aliquat 336 (methyl trioctyl ammonium chloride, Aldrich St. Louis, MO, USA), Cyphos IL 101 (trihexyl(tetradecyl)phosphonium chloride, >97% Solvionic, Toulouse, France), and RILC8_Br (3-(1,3-diethoxy-1,3-dioxopropan-2-yl)-1-octylimidazolium bromide, synthesis described in [18]). Experimental studies were carried out in the system described in detail in [18,19]. The feed solution was composed of Zn(II), Cd(II), Cu(II), and Pb(II) nitrates (Sigma-Aldrich, St. Louis, MO, USA, reagent grade, purity ≥ 98%) dissolved in 0.5 M HCl (200 cm3) with an initial concentration equal to 0.002 M. Only in the system with D2EHPA as a carrier, due to its properties, was a 0.002 M solution of metal ions (initial pH = 4) without HCl used. As the stripping phase, a nitric acid solution with a concentration of 0.5 M and volume of 100 cm3 was applied. The surface membrane area was equal to 17 cm2. The aqueous solutions were pumped from the external reservoirs by a peristaltic pump (GILSON MINIPULS 3) at a 16 cm3/min flow rate. During the transport experiments, 1 mL samples from the feed and the receiving solution were taken for analysis with the flame atomic absorption method using a SPECTRAA 20ABQ Varian spectrophotometer. The atomic absorption spectroscopy operating parameters are presented in the Supplementary File (Table S2). All the experiments were carried out at room temperature (25 ± 2 °C).

2.1. Membrane Preparation

PIMs were prepared according to the procedure described in [18,19] using a solution casting and solvent evaporation technique. Cellulose triacetate (Acros Organics, Morris Plains, NJ, USA), as a polymer matrix, and o-nitrophenyl octyl ether (Alfa Aesar, Kandel, Germany, 98%), as a plasticizer, were used. The composition and thickness of the membranes applied in the experiments are presented in Table 1.

2.2. Model Calculations

The ordinary differential equations (ODEs) were solved with the Berkeley Madonna program v.8.1 (Berkeley, CA, USA) using the Rosenbrock (stiff) method. This method is related to the Runge–Kutta method; however, it possesses excellent stability properties, is computationally efficient, and preserves the positivity of the solutions [38,39]. The parameter values were estimated using the curve fit procedure which minimizes the deviation between the model output and dataset. The dependences of concentration changes in the feed and stripping solution were fitted simultaneously.
The most common parameter used to select the model with the best fit quality is the determination coefficient. However, it was proven that for nonlinear models, the application of the determination coefficient for the model selection is questionable because R-squared does not distinguish between good and bad nonlinear models [40].
Therefore, as the fit quality parameter, the standard error of the regression (sy) was calculated using the following equation:
s y = M S E = R S S n p 1 = ( y i y ^ i ) 2 n p 1
where RSS denotes the residual sum of squares, MSE is the mean squared error, yi is the observed value of the response variable, y ^ i is a predicted value of the response variable, n is the number of observations (the sample size), and p is the (total) number of estimated parameters.
Moreover, the criteria for model selection among a finite set of models, such as the Akaike information criterion (AIC), Bayesian (Schwarz) information criterion (BIC), and Hannan–Quinn information criterion (HQC), were also calculated. These criteria are most frequently applied as measures of the goodness of fit of a statistical model and are defined by [40]
AIC = 2 p   -   ln ( L )
BIC = p ln ( n )   -   2 ln ( L )
where ln(L) denotes the log-likelihood function of the statistical model defined by
ln ( L ) = 0 . 5 n ln ( 2 π ) + 1 ln n + ln ( R S S )
The Hannan–Quinn information criterion was calculated using the following equation [41]:
HQC = n ln R S S n + 2 p ln ( ln ( n ) )
Note that the model with lower sy, AIC, BIC, and HQC values is preferred.
Before the model selection, another test should be performed to examine the random distribution of the residuals. For this purpose, a nonparametric runs test was used [42]. The best model was therefore selected from those in which the randomness of the residuals was fulfilled.

3. Results

3.1. Influence of the Feed and Stripping Solution Volume Changes

During the operation of the membrane system, samples of the feed and receiving solution were taken for concentration analysis (without return). Consequently, the effect of the change in the volume of the respective solutions was taken into account in the model calculations. The actual change in volume can be described by a step function, which is problematic to include in numerical calculations carried out in the Berkeley Madonna ODE solver. Therefore, a nonlinear function (third-degree polynomial) was used to describe the continuous change in volume during the system operation. As an example, in Figure 1a, the results of the calculations for the model proposed by Danesi are compared with those of the same model taking into account the influence of the feed and receiving solution volume (step and continuous). A comparison of the fits of the models represented by Equations (7) and (8) is presented in Figure 1b.
The results of the concentration vs. time dependence calculations for the feed solution are almost the same regardless of whether the change in volume is taken into account or not. For the stripping solution dependence, the application of the continuous (solid line) or step function (dotted line) for the description of the volume changes leads to a much better fit of the model to the experimental data. The percentage error between the calculated values of concentration in the receiving solution for the two best-fit models does not exceed 1%. Therefore, the solution volume changes in the membrane system were described by the third-degree polynomial in further model calculations. An example of a third-degree polynomial fitting to the experimental results is presented in the Supplementary File (Figure S1).

3.2. TOPO as a Carrier

The experimental results of Cd(II), Zn(II), Pb(II), and Cu(II) ion transport through PIMs with TOPO as a carrier were used for the best model selection. No transport of Cu(II) ions was observed in this study, i.e., the concentration was below the detection limit of AAS. The values of the fit quality parameters and the initial maximum fluxes are listed in Table 2. The lowest values are in bold.
The results indicate that in the case of Cd(II) and Zn(II) ion transport, the lowest values of the sy, AIC, BIC, and HQC parameters were obtained for model No. 4, while model No. 3 was best-fitted to the experimental data of Pb(II) ion transport. Despite the similarity of the values of the initial fluxes calculated using different models, it should be remembered that the fit quality of the models is different. For example, Figure 2 depicts the fit of model No. 1 (dashed line) and model No. 4 (solid line) to the experimental data of Zn(II) transport. Model No. 1 was the worst-fit model, whereas model No. 4 was the best-fit model. Furthermore, model No. 1 (and models No. 2 and No. 3) also failed the runs test because the residuals were not randomly distributed. The best-fit models for all the transported ions and systems are presented in the Supplementary File.
The Zn(II) concentration differences in the feed solution, calculated by models No. 1 and No. 4, were small. Therefore, the same values of the initial maximum fluxes (JM = 3.400 × 10−10 mol/cm2·s) were evaluated. Significant differences are visible only in the concentration dependences for the receiving solution, leading to a maximum percentage error exceeding 5% at the end of the transport. Such a value is inacceptable when the model is used in analytical applications, e.g., to predict the enrichment factor of analytes.

3.3. Aliquat 336 as a Carrier

The kinetic models were applied for the description of the transport of Cd(II), Zn(II), Pb(II), and Cu(II) ions through PIMs containing Aliquat 336 as a carrier. Similar to the system with TOPO as a carrier, transport of Cu(II) ions was not observed (below the detection limit of AAS). The calculated model fit quality parameters are presented in Table 3, along with the initial maximum fluxes. Based on these quantities, the most appropriate models were selected.
Model No. 4 provided the lowest values of all the model fit quality parameters for Zn(II) and Pb(II) ion transport, whereas model No. 3 showed the best fit in the case of Cd(II) ion transport. In this membrane system, the best-fitted models led to initial maximum fluxes higher than 7 to 11%, especially for preferentially transported Cd(II) and Zn(II) ions.
A comparison of the fits of models No. 3 and No. 1 to the experimental data for Cd(II) ion transport is shown in Figure 3.
The experimental results and the fitted model No. 3 indicate the occurrence of a time lag in the investigated system and thus the accumulation of transported Cd(II) in the membrane. The same effect was also observed for Zn(II) and Pb(II) ion transport. This phenomenon is fundamental in analytical applications since accumulation reduces the transport efficiency and enrichment factor. Note that for models No. 1 and No. 2, the accumulation of the transported substance in the membrane was not taken into account.

3.4. Cyphos IL 101 as a Carrier

The fit quality measures obtained from fitting the kinetic models to the experimental data of Cd(II), Zn(II), Pb(II), and Cu(II) ion transport through PIMs containing Cyphos IL 101 as a carrier are presented in Table 4.
The lowest values—which indicate a better fit of the model to the experimental data—were observed for model No. 3 used for the description of the Cd(II) and Pb(II) concentration vs. time dependences. In the case of Zn(II) and Cu(II) ion transport, only one model satisfied the criterion of the randomness of the data. For the Cu(II) ions, it was model No. 2, and for the Zn(II) ions, it was model No. 4. The results show that, similar to the system with Aliquat 336 as the carrier, for Cd(II), Zn(II), and Pb(II) ion transport, accumulation in the membrane was also observed. The biggest difference between the initial maximum flux values calculated from the appropriate models was found for the transport of Cu(II) ions; the JM calculated by the correctly fitted model was over 55% higher than the values calculated by the other models. The fitting of the worst (model No. 1) and best models (No. 4) to the experimental data of Zn(II) ion transport is compared in Figure 4.
The fits of models No. 1 and No. 4 to the dependence of the concentration changes in the feed solution were similar, leading to almost identical flux values of Zn(II) ions. For Cyphos IL 101 as a carrier in PIMs, accumulation of transported Cd(II), Zn(II), and Pb(II) ions in the membrane was also observed. Differences in the fit of the models appear for the receiving solution concentration vs. time dependence, indicating that the fit of model No. 5 is much better.

3.5. D2EHPA as a Carrier

The calculated fit quality characteristics of the analyzed models used for the description of Cd(II), Zn(II), Pb(II), and Cu(II) ion transport through PIMs containing D2EHPA as a carrier are compared in Table 5.
The transport kinetics in this system can be described by various models satisfying the criterion of the randomness of the data, especially for the transport of Cd(II) ions. From the comparison of the fit quality parameter results, all of the fit criteria using model No. 3 were lower than those of the other models for Cd(II) and Zn(II) ion transport. The lowest sy, AIC, BIC, and HQC values for Pb(II) ion transport were found for model No. 4, while for Cu(II) ions, the lowest values were found for model No. 2. The calculated initial maximum fluxes using different models were similar. However, a decidedly different fit of the models to the experimental data was observed (see Figure 5). For Cu(II) ion transport, the initial maximum flux calculated by model No. 2 was approx. 14% higher when compared to the values calculated by the other models.

3.6. Reactive Ionic Liquid (RILC8_Br) as a Carrier

A summary of the fit quality measures of the analyzed models is presented in Table 6. In this membrane system, no transport of Cu(II) ions was observed.
All the fit quality measures indicate that there was only one kinetic model appropriate for the description of Cd(II), Zn(II), and Pb(II) ion transport through PIMs using RILC8_Br as a carrier. In the case of Cd(II) and Zn(II) ion transport, except for model No. 2, no other model met the random distribution of residuals criterion. Choosing an inappropriate model leads to substantial errors in the initial maximum flux values. The calculated JM values from the best-fit model were higher by approx. 22% for Cd(II) ions and up to 74% for Zn(II) ions. The proper choice of this model for the description of metal ion transport through PIMs containing reactive ionic liquids was also confirmed by the results presented in [18].
The fit of models No. 2 and No. 4 to the experimental data of Cd(II) ion transport is shown in Figure 6. The results indicate a much better fit of model No. 2. Moreover, no time lag effect was observed in the investigated system. The undetectable time lag may result primarily from the properties of the carrier used, as well as the application of the thinnest membrane in the experiments.

4. Conclusions

An appropriate mathematical model enables a quantitative prediction of concentration changes in external solutions and the calculation of, e.g., the time needed to achieve the maximum concentration, recovery, or enrichment factor of the transported substances.
Among the numerous equations used to describe transport kinetics, it is impossible to choose only one as the most appropriate. The presented results indicated that the application of the most frequently used model (proposed by Danesi) is significantly limited because of the nonrandomly distributed residuals.
The selection of the appropriate model should be based on the values of the standard error of the regression, Akaike information criterion (AIC), Bayesian (Schwarz) information criterion (BIC), or Hannan–Quinn information criterion (HQC) after the runs test evaluation (residuals’ randomness check).
Of the models presented in this report, model No. 4 is the most universal. However, the model selection should be individualized for each experimental relationship. It was also found that a nonlinear equation (third-degree polynomial) can be successfully used to describe solutions’ volume changes in a membrane system (because of sampling), leading to a better fit of the model to the experimental data.
The results indicated that the models that have not been used thus far for transport description in PIMs, i.e., models No. 3 and No. 4, can be successfully applied. These models are particularly important in the case of systems where a time lag is observed. This mainly applies to systems with carriers characterized by a high partition coefficient (high sorption of transported substances to the membrane), slow diffusion inside the membrane (e.g., because of the relatively high membrane thickness), or slow kinetics of extraction and re-extraction at the respective membrane interfaces.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/membranes13020236/s1, Table S1. List of differential equations used in an appropriate models. Table S2. Atomic absorption spectroscopy operating parameters. Table S3. The calculated kinetic parameters and initial maximum fluxes for the system with TOPO as a carrier. Table S4. The calculated kinetic parameters and initial maximum fluxes for the system with Aliquat 336 as a carrier. Table S5. The calculated kinetic parameters and initial maximum fluxes for the system with Cyphos IL 101 as a carrier. Table S6. The calculated kinetic parameters and initial maximum fluxes for the system with D2EHPA as a carrier. Table S7. The calculated kinetic parameters and initial maximum fluxes for the system with reactive ionic liquid (RILC8_Br) as a carrier. Figure S1. The 3rd degree polynomial fitting to the experimental results for system with D2EHPA as a carrier. Figure S2. The best fitted models for predicting Cd(II) (a), Zn(II) (b), and Pb(II) (c) ions transport through PIM with TOPO as a carrier. Figure S3. The best fitted models for predicting Cd(II) (a), Zn(II) (b), and Pb(II) (c) ions transport through PIM with Aliquat 336 as a carrier. Figure S4. The best fitted models for predicting Cd(II) (a), Zn(II) (b), Pb(II) (c), and Cu(II) (d) ions transport through PIM with Cyphos IL 101 as a carrier. Figure S5. The best fitted models for predicting Cd(II) (a), Zn(II) (b), Pb(II) (c), and Cu(II) (d) ions transport through PIM with D2EHPA as a carrier. Figure S6. The best fitted models for predicting Cd(II) (a), Zn(II) (b), and Pb(II) (c) ions transport through PIM with a reactive ionic liquid (RILC8_Br) as a carrier.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Data is contained within the article or Supplementary Material.

Conflicts of Interest

The author declare no conflict of interest.

References

  1. Almeida, I.M.G.S.; Cattrall, R.W.; Kolev, S.D. Recent trends in extraction and transport of metal ions using polymer inclusion membranes (PIMs). J. Membr. Sci. 2012, 415–416, 9–23. [Google Scholar] [CrossRef]
  2. Almeida, I.M.G.S.; Cattrall, R.W.; Kolev, S.D. Polymer inclusion membranes (PIMs) in chemical analysis—A review. Anal. Chim. Acta 2017, 987, 1–14. [Google Scholar] [CrossRef] [PubMed]
  3. Maiphetlho, K.; Chimuka, L.; Tutu, H.; Richards, H. Technical design and optimisation of polymer inclusion membranes (PIMs) for sample pre-treatment and passive sampling—A review. Sci. Total Environ. 2021, 799, 149483. [Google Scholar] [CrossRef]
  4. Keskin, B.; Zeytuncu-Gökoğlu, B.; Koyuncu, I. Polymer inclusion membrane applications for transport of metal ions: A critical review. Chemosphere 2021, 279, 130604. [Google Scholar] [CrossRef] [PubMed]
  5. López-Guerrero, M.M.; Granado-Castro, M.D.; Díaz-de-Alba, M.; Lande-Durán, J.; Casanueva-Marenco, M.J. A polymer inclusion membrane for the simultaneous determination of Cu(II), Ni(II) and Cd(II) ions from natural waters. Microchem. J. 2020, 157, 104980. [Google Scholar] [CrossRef]
  6. Chimuka, L.; Cukrowska, E.; Michel, M.; Buszewski, B. Advances in sample preparation using membrane-based liquid-phase microextraction techniques. TrAC Trends Anal. Chem. 2011, 30, 1781–1792. [Google Scholar] [CrossRef]
  7. Danesi, P.R. Separation of metal species by supported liquid membranes. Sep. Sci. Technol. 1984, 19, 857–894. [Google Scholar] [CrossRef]
  8. Alcalde, B.; Anticó, E.; Fontàs, C. Fluoride removal from natural waters by polymer inclusion membranes. J. Membr. Sci. 2022, 644, 120161. [Google Scholar] [CrossRef]
  9. Kiswandono, A.A.; Nusantari, C.S.; Rinawati, R.; Hadi, S. Optimization and Evaluation of Polymer Inclusion Membranes Based on PVC Containing Copoly-EDVB 4% as a Carrier for the Removal of Phenol Solutions. Membranes 2022, 12, 295. [Google Scholar] [CrossRef]
  10. Zawierucha, I.; Nowik-Zajac, A.; Lagiewka, J.; Malina, G. Separation of Mercury(II) from Industrial Wastewater through Polymer Inclusion Membranes with Calix[4]pyrrole Derivative. Membranes 2022, 12, 492. [Google Scholar] [CrossRef]
  11. Xu, L.; Zeng, X.; He, Q.; Deng, T.; Zhang, C.; Zhang, W. Stable ionic liquid-based polymer inclusion membranes for lithium and magnesium separation. Sep. Purif. Technol. 2022, 288, 120626. [Google Scholar] [CrossRef]
  12. Zeng, X.; Xu, L.; Deng, T.; Zhang, C.; Xu, W.; Zhang, W. Polymer Inclusion Membranes with P507-TBP Carriers for Lithium Extraction from Brines. Membranes 2022, 12, 839. [Google Scholar] [CrossRef] [PubMed]
  13. Meziani, R.; Mitiche, L.; Fontàs, C.; Sahmoune, A. Polymer inclusion membranes with ionic liquids for the recovery of the technology-critical element Bi(III). Chem. Eng. Process. Process Intensif. 2022, 175, 108911. [Google Scholar] [CrossRef]
  14. Hedwig, S.; Kraus, M.; Amrein, M.; Stiehm, J.; Constable, E.C.; Lenz, M. Recovery of scandium from acidic waste solutions by means of polymer inclusion membranes. Hydrometallurgy 2022, 213, 105916. [Google Scholar] [CrossRef]
  15. Govindappa, H.; Bhat, M.P.; Uthappa, U.T.; Sriram, G.; Altalhi, T.; Prasanna Kumar, S.; Kurkuri, M. Fabrication of a novel polymer inclusion membrane from recycled polyvinyl chloride for the real-time extraction of arsenic (V) from water samples in a continuous process. Chem. Eng. Res. Des. 2022, 182, 145–156. [Google Scholar] [CrossRef]
  16. Radzyminska-Lenarcik, E.; Kwiatkowska-Marks, S.; Kosciuszko, A. Transport of Heavy Metals Pb(II), Zn(II), and Cd(II) Ions across CTA Polymer Membranes Containing Alkyl-Triazole as Ions Carrier. Membranes 2022, 12, 1068. [Google Scholar] [CrossRef]
  17. Olasupo, A.; Sadiq, A.C.; Suah, F.B.M. A novel approach in the removal of ciprofloxacin antibiotic in an aquatic system using polymer inclusion membrane. Environ. Technol. Innov. 2022, 27, 102523. [Google Scholar] [CrossRef]
  18. Szczepański, P.; Guo, H.; Dzieszkowski, K.; Rafiński, Z.; Wolan, A.; Fatyeyeva, K.; Kujawa, J.; Kujawski, W. New reactive ionic liquids as carriers in polymer inclusion membranes for transport and separation of Cd(II), Cu(II), Pb(II), and Zn(II) ions from chloride aqueous solutions. J. Membr. Sci. 2021, 638, 119674. [Google Scholar] [CrossRef]
  19. Szczepański, P. Some Critical Remarks about Mathematical Model Used for the Description of Transport Kinetics in Polymer Inclusion Membrane Systems. Membranes 2020, 10, 411. [Google Scholar] [CrossRef]
  20. Konczyk, J.; Ciesielski, W. Calixresorcin[4]arene-Mediated Transport of Pb(II) Ions through Polymer Inclusion Membrane. Membranes 2021, 11, 285. [Google Scholar] [CrossRef]
  21. Zhang, W.; Liu, J.; Ren, Z.; Wang, S.; Du, C.; Ma, J. Kinetic study of chromium(VI) facilitated transport through a bulk liquid membrane using tri-n-butyl phosphate as carrier. Chem. Eng. J. 2009, 150, 83–89. [Google Scholar] [CrossRef]
  22. Alpaydin, S.; Saf, A.Ö.; Bozkurt, S.; Sirit, A. Kinetic study on removal of toxic metal Cr(VI) through a bulk liquid membrane containing p-tert-butylcalix[4]arene derivative. Desalination 2011, 275, 166–171. [Google Scholar] [CrossRef]
  23. Religa, P.; Gawroński, R.; Gierycz, P. Kinetics of Chromium(III) Transport Through a Liquid Membrane Containing DNNSA as a Carrier. Int. J. Mol. Sci. 2009, 10, 964–975. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  24. Alpoguz, H.K.; Kaya, A.; Sener, I. Carrier-Mediated Transport of Hg(II) through Bulk and Supported Liquid Membranes. J. Macromol. Sci. Part A Pure Appl. Chem. 2007, 44, 1061–1068. [Google Scholar] [CrossRef]
  25. Ersoz, M. Transport of mercury through liquid membranes containing calixarene carriers. Adv. Colloid Interface Sci. 2007, 134–135, 96–104. [Google Scholar] [CrossRef]
  26. León, G.; Guzmán, M.A. Kinetic study of the effect of carrier and stripping agent concentrations on the facilitated transport of cobalt through bulk liquid membranes. Desalination 2005, 184, 79–87. [Google Scholar] [CrossRef]
  27. He, D.; Ma, M. Effect of paraffin and surfactant on coupled transport of cadmium(II) ions through liquid membranes. Hydrometallurgy 2000, 56, 157–170. [Google Scholar] [CrossRef]
  28. Aydiner, C.; Kobya, M.; Demirbas, E. Cyanide ions transport from aqueous solutions by using quaternary ammonium salts through bulk liquid membranes. Desalination 2005, 180, 139–150. [Google Scholar] [CrossRef]
  29. Kobya, M.; Demirbas, E.; Dernircioglu, N.; Yildirimd, Y.; Yildiz, Y.S. Effect of carrier type on coupled transport kinetics of thiocyanate ions through liquid membranes. Desalination 2004, 160, 253–262. [Google Scholar] [CrossRef]
  30. Cichy, W.; Schlosser, Š.; Szymanowski, J. Extraction and pertraction of phenol through bulk liquid membranes. J. Chem. Technol. Biotechnol. 2004, 80, 189–197. [Google Scholar] [CrossRef]
  31. Ma, M.; He, D.; Liao, S.; Zeng, Y.; Xie, Q.; Yao, S. Kinetic study of L-isoleucine transport through a liquid membrane containing di(2-ethylhexyl) phosphoric acid in kerosene. Anal. Chim. Acta 2002, 456, 157–165. [Google Scholar] [CrossRef]
  32. Rajec, P.; Mikulaj, V.; Mackova, J. Pertraction of strontium in bulk liquid membrane systems using crown ether as a carrier. J. Radioanal. Nucl. Chem. 1991, 150, 315–323. [Google Scholar] [CrossRef]
  33. Hoque, B.; Almeida, M.I.G.S.; Cattrall, R.W.; Gopakumar, T.G.; Kolev, S.D. Effect of cross-linking on the performance of polymer inclusion membranes (PIMs) for the extraction, transport and separation of Zn(II). J. Membr. Sci. 2019, 589, 117256. [Google Scholar] [CrossRef]
  34. St John, A.M.; Cattrall, R.W.; Kolev, S.D. Determination of the initial flux of polymer inclusion membranes. Sep. Purif. Technol. 2013, 116, 41–45. [Google Scholar] [CrossRef]
  35. O’Bryan, Y.; Cattrall, R.W.; Truong, Y.B.; Kyratzis, I.L.; Kolev, S.D. The use of poly(vinylidenefluoride-co-hexafluoropropylene) for the preparation of polymer inclusion membranes. application to the extraction of thiocyanate. J. Membr. Sci. 2016, 510, 481–488. [Google Scholar] [CrossRef]
  36. Croft, C.F.; Almeida, M.I.G.S.; Cattrall, R.W.; Kolev, S.D. Separation of lanthanum(III), gadolinium(III) and ytterbium(III) from sulfuric acid solutions by using a polymer inclusion membrane. J. Membr. Sci. 2018, 545, 259–265. [Google Scholar] [CrossRef]
  37. Bonggotgetsakul, Y.Y.N.; Cattrall, R.W.; Kolev, S.D. The Effect of Surface Confined Gold Nanoparticles in Blocking the Extraction of Nitrate by PVC-Based Polymer Inclusion Membranes Containing Aliquat 336 as the Carrier. Membranes 2018, 8, 6. [Google Scholar] [CrossRef] [Green Version]
  38. Voss, D.A.; Khaliq, A.Q.M. Parallel Rosenbrock methods for chemical systems. Comput. Chem. 2001, 25, 101–107. [Google Scholar] [CrossRef]
  39. Ostermann, A.; Roche, M. Rosenbrock methods for partial differential equations and fractional orders of convergence. SIAM J. Numer. Anal. 1993, 30, 1084–1098. Available online: http://www.jstor.org/stable/2158191 (accessed on 2 January 2023). [CrossRef]
  40. Spiess, A.-N.; Neumeyer, N. An evaluation of R2 as an inadequate measure for nonlinear models in pharmacological and biochemical research: A Monte Carlo approach. BMC Pharmacol. 2010, 10, 6. [Google Scholar] [CrossRef] [Green Version]
  41. Ayalew, S.; Chitti Babu, M.; Mohana Rao, L.K. Comparison of New Approach Criteria for Estimating the Order of Autoregressive Process. IOSR J. Math. (IOSRJM) 2012, 1, 10–20. Available online: https://iosrjournals.org/iosr-jm/papers/vol1-issue3/C0131020.pdf (accessed on 2 January 2023).
  42. Janke, S.J.; Tinsley, F.C. Introduction to Linear Models and Statistical Inference; John Wiley & Sons, Inc.: Hoboken, NJ, USA, 2005; pp. 191–194. [Google Scholar]
Figure 1. Comparison of the model that does not take into account the volume changes (dashed lines) with the models using a continuous function (solid lines) and a step function (dotted lines) to describe the changes in the volume. The systems use D2EHPA (a) and RILC8_Br (b) as carriers.
Figure 1. Comparison of the model that does not take into account the volume changes (dashed lines) with the models using a continuous function (solid lines) and a step function (dotted lines) to describe the changes in the volume. The systems use D2EHPA (a) and RILC8_Br (b) as carriers.
Membranes 13 00236 g001
Figure 2. Comparison of the best (model No. 4, solid line) and worst (model No. 1, dashed line) model fits for predicting Zn(II) ion transport through PIMs with TOPO as a carrier.
Figure 2. Comparison of the best (model No. 4, solid line) and worst (model No. 1, dashed line) model fits for predicting Zn(II) ion transport through PIMs with TOPO as a carrier.
Membranes 13 00236 g002
Figure 3. The best (model No. 3, solid line) and worst (model No. 1, dashed line) model fits for predicting Cd(II) ion transport through PIMs with Aliquat 336 as a carrier.
Figure 3. The best (model No. 3, solid line) and worst (model No. 1, dashed line) model fits for predicting Cd(II) ion transport through PIMs with Aliquat 336 as a carrier.
Membranes 13 00236 g003
Figure 4. The best (model No. 4, solid line) and worst (model No. 1, dashed line) model fits for predicting Zn(II) ion transport through PIMs with Cyphos IL 101 as a carrier.
Figure 4. The best (model No. 4, solid line) and worst (model No. 1, dashed line) model fits for predicting Zn(II) ion transport through PIMs with Cyphos IL 101 as a carrier.
Membranes 13 00236 g004
Figure 5. Comparison of the best (model No. 4, solid line) and worst (model No. 1, dashed line) model fits for predicting Pb(II) ion transport through PIMs with D2EHPA as a carrier.
Figure 5. Comparison of the best (model No. 4, solid line) and worst (model No. 1, dashed line) model fits for predicting Pb(II) ion transport through PIMs with D2EHPA as a carrier.
Membranes 13 00236 g005
Figure 6. Comparison of the best model fit (model No. 2, solid line) and the fit of the model represented by Equations (14)–(16) (model No. 4, dashed line) to the experimental data of Cd(II) ion transport through PIMs with RILC8_Br as a carrier.
Figure 6. Comparison of the best model fit (model No. 2, solid line) and the fit of the model represented by Equations (14)–(16) (model No. 4, dashed line) to the experimental data of Cd(II) ion transport through PIMs with RILC8_Br as a carrier.
Membranes 13 00236 g006
Table 1. The composition and thickness of the membranes used.
Table 1. The composition and thickness of the membranes used.
Carrier TypeMembrane Composition [wt%]Thickness [mm]
CarrierNPOECTA
TOPO5230180.100 (±0.005)
Aliquat 3364431250.149 (±0.011)
Cyphos IL 1014919320.1498 (±0.0014)
D2EHPA4629250.199 (±0.043)
RILC8_Br5020300.0972 (±0.0074)
Table 2. The calculated fit quality parameters and initial maximum fluxes for the system with TOPO as a carrier.
Table 2. The calculated fit quality parameters and initial maximum fluxes for the system with TOPO as a carrier.
IonNo.SchemeV = f(t)Randomness in Data
(Runs Test)
sy × 105AICBICHQCJM × 1010
[mol/cm2·s]
Cd (II)1A→BNONO7.97−288.76−287.87−339.723.006
1aA→BYESNO6.49−296.16−295.27−347.122.926
2A↔BYESNO6.70−294.18−292.40−345.012.924
3A→B→CYESYES3.67−315.82−311.15−366.663.036
4A↔B→CYESYES3.21−319.94−317.27−370.652.989
Zn (II)1A→BNONO9.66−281.85−280.96−332.813.400
1aA→BYESNO7.52−290.86−289.97−341.823.332
2A↔BYESNO7.77−288.86−287.08−339.693.332
3A→B→CYESNO5.57−300.85−296.18−351.693.477
4A↔B→CYESYES2.87−324.00−321.33−374.713.400
Pb (II)1A→BNOYES1.68−344.75−343.86−395.710.2411
1aA→BYESYES1.52−348.50−347.61−399.460.2342
2A↔BYESYES1.26−354.47−352.69−405.310.2485
3A→B→CYESYES1.57−346.50−341.83−397.330.2342
4A↔B→CYESYES1.61−344.82−342.15−395.540.2342
Table 3. The calculated fit quality parameters and initial maximum fluxes for the system with Aliquat 336 as a carrier.
Table 3. The calculated fit quality parameters and initial maximum fluxes for the system with Aliquat 336 as a carrier.
IonNo.SchemeV = f(t)Randomness in Data
(Runs Test)
Sy × 105AICBICHQCJM × 1010
[mol/cm2·s]
Cd (II)1A→BNONO13.1−301.06−300.07−357.623.476
1aA→BYESYES12.2−303.68−302.69−360.253.347
2A↔BYESYES12.6−301.71−302.72−358.083.345
3A→B→CYESYES4.53−342.57−343.57−398.943.718
4A↔B→CYESYES4.67−340.57−343.57−396.743.718
Zn (II)1A→BNONO14.8−295.99−294.99−352.551.512
1aA→BYESNO13.6−299.52−298.52−356.081.473
2A↔BYESNO14.0−297.52−298.52−353.891.473
3A→B→CYESYES8.59−316.98−317.99−373.351.680
4A↔B→CYESYES6.36−328.20−331.21−384.381.620
Pb (II)1A→BNONO3.06−359.07−358.07−415.630.3340
1aA→BYESYES2.82−362.46−361.46−419.020.3265
2A↔BYESYES2.90−360.46−361.46−416.830.3265
3A→B→CYESYES2.18−371.92−372.92−428.290.3363
4A↔B→CYESYES2.01−374.30−377.30−430.470.3424
Table 4. The calculated fit quality parameters and initial maximum fluxes for the system with Cyphos IL 101 as a carrier.
Table 4. The calculated fit quality parameters and initial maximum fluxes for the system with Cyphos IL 101 as a carrier.
IonNo.SchemeV = f(t)Randomness in Data
(Runs Test)
sy × 105AICBICHQCJM × 1010
[mol/cm2·s]
Cd (II)1A→BNONO9.53−313.70−312.70−370.263.206
1aA→BYESNO8.96−316.14−315.15−372.703.067
2A↔BYESYES9.22−314.15−312.15−370.513.067
3A→B→CYESYES3.30−355.19−350.21−411.563.240
4A↔B→CYESYES3.41−353.20−350.22−409.383.241
Zn (II)1A→BNONO10.6−309.47−308.48−366.032.254
1aA→BYESNO8.95−316.17−315.18−372.742.190
2A↔BYESNO9.21−314.17−312.18−372.732.190
3A→B→CYESNO5.00−338.60−333.61−397.162.307
4A↔B→CYESYES4.00−346.78−343.79−407.342.234
Pb (II)1A→BNONO26.9−272.21−271.21−328.770.7189
1aA→BYESNO3.79−350.57−349.57−407.130.7000
2A↔BYESNO3.90−348.57−346.57−404.930.7000
3A→B→CYESYES3.03−358.61−353.63−414.980.7170
4A↔B→CYESYES3.09−356.98−353.99−413.150.7168
Cu (II)1A→BNONO0.312−225.39−225.09−254.100.007139
1aA→BYESNO0.322−224.73−224.42−253.440.006916
2A↔BYESYES0.132−241.96−241.36−271.010.01110
3A→B→CYESNO0.345−222.73−219.82−251.770.006916
4A↔B→CYESNO0.373−220.73−219.83−250.110.006917
Table 5. The calculated fit quality parameters and initial maximum fluxes for the system with D2EHPA as a carrier.
Table 5. The calculated fit quality parameters and initial maximum fluxes for the system with D2EHPA as a carrier.
IonNo.SchemeV = f(t)Randomness in Data
(Runs Test)
sy × 105AICBICHQCJM × 1010
[mol/cm2·s]
Cd (II)1A→BNOYES4.10−347.39−346.39−403.950.4684
1aA→BYESYES4.29−345.58−344.58−402.140.4548
2A↔BYESYES4.43−343.49−341.50−399.860.4579
3A→B→CYESYES2.90−360.39−355.41−416.760.4757
4A↔B→CYESYES3.38−353.53−350.54−409.710.4652
Zn (II)1A→BNONO6.36−329.88−328.89−386.443.514
1aA→BYESNO5.24−337.63−336.63−394.193.413
2A↔BYESNO5.42−335.39−333.40−391.763.421
3A→B→CYESYES3.44−353.59−348.61−409.963.527
4A↔B→CYESYES3.51−352.03−349.04−408.213.512
Pb (II)1A→BNONO10.3−310.67−309.68−367.242.792
1aA→BYESYES7.91−321.14−320.15−377.712.747
2A↔BYESYES8.14−319.14−320.15−375.512.747
3A→B→CYESNO5.75−333.02−334.03−389.392.881
4A↔B→CYESYES2.37−367.68−370.68−423.852.822
Cu (II)1A→BNOYES2.27−371.02−370.02−427.580.2180
1aA→BYESNO2.29−370.80−369.81−427.370.2121
2A↔BYESYES1.31−392.16−393.16−448.530.2425
3A→B→CYESNO2.35−368.80−369.81−425.170.2121
4A↔B→CYESNO2.42−366.88−369.89−423.060.2122
Table 6. The calculated fit quality parameters and initial maximum fluxes for the system with a reactive ionic liquid (RILC8_Br) as a carrier.
Table 6. The calculated fit quality parameters and initial maximum fluxes for the system with a reactive ionic liquid (RILC8_Br) as a carrier.
IonNo.SchemeV = f(t)Randomness in Data
(Runs Test)
sy × 105AICBICHQCJM × 1011
[mol/cm2·s]
Cd (II)1A→BNONO7.19−322.84−321.95−379.417.499
1aA→BYESNO7.04−323.72−322.82−380.287.260
2A↔BYESYES2.286−367.70−365.93−424.089.190
3A→B→CYESNO8.74−314.07−309.40−370.447.260
4A↔B→CYESNO9.00−311.99−309.32−368.167.260
Zn (II)1A→BNONO4.99−337.41−336.52−393.971.386
1aA→BYESNO5.09−336.61−335.72−393.171.345
2A↔BYESYES1.66−380.57−378.79−436.952.414
3A→B→CYESNO5.23−334.61−329.94−390.981.345
4A↔B→CYESNO5.69−332.61−329.94−388.781.346
Pb (II)1A→BNOYES1.79−378.51−377.62−435.071.075
1aA→BYESYES1.84−377.49−376.59−434.051.049
2A↔BYESYES0.651−417.98−416.19−474.341.344
3A→B→CYESYES1.88−375.49−370.81−431.861.049
4A↔B→CYESYES1.93−373.53−370.86−429.701.049
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Szczepański, P. Comparison of Kinetic Models Applied for Transport Description in Polymer Inclusion Membranes. Membranes 2023, 13, 236. https://doi.org/10.3390/membranes13020236

AMA Style

Szczepański P. Comparison of Kinetic Models Applied for Transport Description in Polymer Inclusion Membranes. Membranes. 2023; 13(2):236. https://doi.org/10.3390/membranes13020236

Chicago/Turabian Style

Szczepański, Piotr. 2023. "Comparison of Kinetic Models Applied for Transport Description in Polymer Inclusion Membranes" Membranes 13, no. 2: 236. https://doi.org/10.3390/membranes13020236

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics