Experimental Study on Fatigue Performance of M24 Twisted-Shear High-Strength Bolt for Assembled Steel Structure

1
College of Civil Engineering, Taiyuan University of Technology, Taiyuan 030024, China
2
College of Transportation Engineering, Shanxi Vocational University of Engineering Science and Technology, Jinzhong 030032, China
*
Author to whom correspondence should be addressed.
Appl. Sci. 2023, 13(7), 4296; https://doi.org/10.3390/app13074296
Submission received: 13 February 2023 / Revised: 22 March 2023 / Accepted: 24 March 2023 / Published: 28 March 2023
(This article belongs to the Special Issue Steel Structures Design and Evaluation in Building Engineering)

Abstract

:
High-strength bolt connection is a kind of main connection mode of prefabricated steel structures. Due to the insufficient fatigue performance of high-strength bolts, the degree of damage in the steel structure is very serious, so the fatigue performance research of high strength bolts cannot be ignored. The research object of the paper is M24 twisted-shear high-strength bolts in a steel structure buildings. Some special tests and results analysis on the normal fatigue performance were carried out, establishing the fatigue S-N curve of M24 twisted-shear high-strength bolts, revealing the fatigue failure mechanism of M24 torsion-shear high-strength bolts; obtaining the fatigue S-N curve equation; and estimating the fatigue life of high-strength bolts by using the Paris formula. In addition, by comparing the test data in this paper with the constant fatigue test data of high-strength bolts in the existing research literature, it can be seen how the strength grade of the bolts and the pretension force have an impact on the fatigue strength. It is further revealed that the M24 torsion-shear high-strength bolt with full pretension force has twice as long fatigue life than the other two types of bolts. By comparing the test results of M24 and M20 bolts under full pretension, it is known the relation between the fatigue strength of the bolts and diameter decreases. The research data and useful conclusions can provide scientific basis and theoretical reference for the anti-fatigue design of M24 torsion-shear high-strength bolt connection.

1. Introduction

High-strength bolt connection is the main connection mode of prefabricated steel structures, and it is widely applied in practical engineering because of its advantages of convenient installation, easily ensuring the construction quality, and high construction efficiency. On-site bolt connection is fast and convenient, but fatigue damage of the bolt nodes will occur under the action of long-term repeated load, so the fatigue performance of bolt nodes cannot be ignored. Since the German engineer W. A. J. Albert proposed the fatigue problem as early as 1829, many scholars have paid attention to it and studied it [1], and different studies on structures’ fatigue problems are gradually appearing, especially considering different kinds of factors such as structural details, structure materials, etc. [2,3,4,5,6,7,8,9].
So, the fatigue problem of high-strength bolt connection is also being paid more and more paid attention. Saranik et al. conducted fatigue test research on high-strength bolts, putting forward the effect of stress concentration on the fatigue performance [10]; Lei et al. have carried out a lot of test and theory research on high-strength bolts’ fatigue problems, and the stress concentration coefficient of M14, M20, M24, M30, M33, M39, M36, M52, M60 was established; the S-N curve was obtained by unified regression analysis; the corresponding constant fatigue design method was established; and the variable fatigue life was estimated with the help of Corten–Dolan theory [11]. Hao et al. fitted the fatigue crack extension rate of S355 and S690 steel by the Walker formula, and the average stress effect was included, based on which random analysis was conducted by the Monte Carlo method, and it was concluded that the guaranteed rate of fatigue crack expansion parameters of steel is 95%, 97.7%, and 99%, respectively [12]. Jiao et al. carried out static analysis of high-strength bolt joints and metallographic analysis of fatigue fracture through a constant amplitude fatigue test, and in 2021 completed the constant amplitude fatigue test of 21 M24 high-strength large hexagon head bolts made of 35K steel and of grade 8.8 with an MTS fatigue tester [13]. Huang carried out the constant amplitude fatigue test of 14 M24 high-strength large hexagon head bolts with the help of an MTS fatigue testing machine [14]. Guo et al. analyzed the fatigue performance of the Q690D high-strength steel bolt connection through the fatigue test, and fitted the S-N curve according to the test data, deducing the fatigue injury formula through the test data [15]. Bai et al. developed a general lumped damage simulation model for predicting the fatigue damage life-cycle and the associated crack propagation in the full range of elastic and plastic amplitudes [16]. Niu et al. analyzed the relationship among defects, fatigue strength, and fatigue curves to extrapolate the probabilistic fatigue curves for AM materials [17]. Li et al. proposed a new probabilistic fatigue model for life assessment by combining the weakest link theory with the strain energy concept, and utilized experimental data of GH4169, TC4, and TC11 alloys with different geometries to carry out model validation and comparison [18].
However, most fatigue studies are focused on high-strength bolts with a grid structure. Currently, there is little research about sudden fatigue failure of a fabricated steel structure buildings Therefore, on the basis of previous research on the fatigue failure type and mechanism of the steel structure, we carried out constant amplitude fatigue tests on the M24 twisted-shear high-strength bolts used in the fabricated steel structure residence. In the study, the nodes between the beam and the column of the fabricated steel structure fully apply twisted-shear high-strength bolts. It is the study prerequisite that the full pretension force was applied to the twisted-shear high-strength bolts before the experiment. Through analyzing test data, we have established the fatigue S-N curve equation of M24 twisted-shear high-strength bolt connection, revealed the fatigue failure mechanism, and developed the design method for constant amplitude fatigue based on the nominal stress, estimating the fatigue life of M24 twisted-shear high-strength bolts based on broken mechanics. In total, this study will provide the scientific basis and theoretical reference for the anti-fatigue design on M24 twisted-shear high-strength bolt connection.

2. Experimental Methods

2.1. Specimen Design

2.1.1. M24 Torsional Shear High-Strength Bolt Connection

Figure 1 shows the M24 torsion-shear high-strength bolt used in the fatigue test, the nominal diameter of which is 24 mm; the length of which is 100 mm; and the composition of which is ML20MnTiB steel, produced in China. It is constituted of one bolt, one nut, and one gasket, exactly the same as the high-strength bolts used in an actual fabricated steel structure. Before the fatigue tests, the bolts’ appearance was visually checked, ensuring that there were no initial defects such as cracks, rust, or bumps on the bolts. The basic performance indexes of the high-strength bolt connection are shown in Table 1.

2.1.2. T-Type Connector

By reference to the Design Standard for Steel Structure (GB50017-2017) [20], a set of T-type load devices was designed for the axial tensile fatigue test of torsion-shear high-strength bolts according to the loading requirements of the fatigue test, considering the connection form and force characteristics of high-strength bolts. The specific processing size of the T-type connector is shown in Figure 2. The loading device is made of Q345B steel. The thickness of the plate is 25 mm; the thickness of the reinforced rib is 14 mm. The connection between the plates includes an open groove weld with equal strength. The steel of the device meets the quality requirements of Q345 of Low Alloy High-Strength Structural Steel (GB/T1591-2018) [21], and the strength and stiffness of the loading device meet the requirements of the fatigue test.

2.2. Mechanical Properties of Bolt’s Material

In order to obtain the static mechanics properties of the M24 twisted-shear high-strength bolt and provide a reference basis for the fatigue test loading scheme, the static tensile test of the M24 twisted-shear high-strength bolt was carried out before the fatigue test. Meanwhile, according to Metallic materials—Tensile testing—Part 1: Method of Test at Room Temperature (GB/T228.1-2010) [22], three M24 twisted-shear high-strength bolt specimens randomly selected were set as a group, No. of which was a, b, and c respectively, and they were processed into standard specimens by machine tools, as shown in Figure 3. The static tensile test of the standard bolt sample was conducted by the MTS test machine, as shown in Figure 4. The material properties obtained from the static tensile test are listed in Table 2. It is seen from the results in the table that the average ultimate tensile strength of the M24 torsion-shear high-strength bolt is 1106.5 MPa, and its average conditional yield strength is 1029.0 MPa. Therefore, the mechanical properties meet the relevant regulations and requirements of the current national standard—Torsional shear High Strength Bolt Link for Steel Structure (GB/T3632-2008) [19]. Then, these properties were applied to the determination of the suitable loading stress level.

2.3. Testing Program and Procedure

2.3.1. Fatigue Test Equipment

The constant amplitude fatigue test of the M24 twisted-shear high-strength bolt connection was carried out in the civil engineering laboratory of Taiyuan University of Technology with a room temperature atmospheric environment. The test equipment included an MTS Landmark 370.50 hydraulic servo fatigue test machine. The device has high load accuracy and the dynamic load capability of 500 kN; the load frequency can reach 100 Hz at most; the loading displacement measurement accuracy reaches 0.00028 mm.

2.3.2. Process and Method of the Test

Following the relevant regulations of Metallic materials-Tensile testing-Axial-Force -Controlled Method (GB/T3075-2008) [23], 10 loading stress levels corresponding to different stress ranges were obtained for the fatigue test according to the above mechanical properties of M24 twisted-shear high-strength bolts, as shown in Table 3.
The stress was calculated as the following Formula (1):
σ = P / A e f f
where P is the axial tension load; Aeff is the effective area of the bolt.
The stress ratio in cyclic loading was set as the following Formula (2):
R = σ min σ max = 0.6
where σmax and σmin are the maximum and minimum stress.
And the stress range was calculated as the following Formula (3):
Δ σ = σ m a x σ m i n
Considering the factors of this test equipment and loading device, etc., the specimens were tested under a constant amplitude sinusoidal loading at a 2~7 Hz frequency; the maximum stress level is about 0.6 fy; and the stress ratio R is 0.6.
The key to the test is that the high-strength bolts should be put the pretension force in order to achieve the purpose of reliable connection. The method of applying the pretension force is shown in Figure 5. When the tail of the torsional shear high-strength bolt is shaken off, the pretension force value of the bolt reaches the specified requirements and, meanwhile, the pretension force of the bolt reaches the specified value 225 kN. The fatigue test loading of the M24 torsion high-strength bolt connection is shown in Figure 6.
There are three steps in the constant amplitude fatigue test. The specific test process is that, first, two high-strength bolts are connected to the left and right sides of the T sample, adjusting the position of two T parts to keep them in the center, and they are finally tightened to maintain the coaxial degree between the T combination sample and fixture. The upper and lower ends of the T combination sample are clamped respectively by the MTS fatigue test machine, in order to put axial tensile force on the bolts; secondly, the samples are loaded after installing, specifically recording the test process and related conditions. During the test, if bolts break or other damage occurs, the MTS test machine will stop loading. When the test stops, the cycle time is recorded as the fatigue life of the damaged bolt, and the fatigue failure map is made; thirdly, the broken bolts are replaced, the load stress amplitude is reset, and the first two steps are repeated to carry out a normal amplitude fatigue test of the next high-strength bolt until the test ends.

3. Experimental Results

3.1. Fatigue Failure Mode

The total 25 M24 twisted-shear high-strength bolts were subjected to the fatigue test. Their fatigue failure forms are presented in Figure 7. It is seen that all the fatigue failures in the test occurred at the root of the high-strength bolt thread, and the failure of most of bolts were located in the first circle of the thread where the nut was engaged with the bolt. Through further analysis, the fatigue failure form of the above bolts can be summarized into the following three modes, as is shown in Table 4.

3.2. Fatigue S-N Curve

In total, 25 satisfactory constant amplitude fatigue tests of the M24 twisted-shear high-strength bolts were carried out. The results of fatigue tests are shown in Table 5, Table 6, Table 7 and Table 8. It is seen that M24-1 and M24-2’s had more than 5 million stress cycles, while M24-13, M24-14, and M24-15 with prestress relaxation during secondary loading had a significantly shorter fatigue life.
Generally, the relationship between the external load and its corresponding fatigue life is described by the S-N curve. The empirical equation of the S-N curve in the form of a power function is given by
N · Δ σ m = C
The S-N curve in logarithmic form can be expressed as follows:
lg N = m lg Δ σ + lg C
Under the 97.72% reliability probability, the formula obtained is as follows:
lg N = m lg Δ σ + lg C 2 s
Combined with the data in the fatigue test process analysis in Table 4, Table 5, Table 6 and Table 7, M24-13~15 were considered as abnormal data points and eliminated due to the prestress relaxation of the secondary loading. Furthermore, over 5 million stress cycle data points of the bolts M24-1 and M24-2 also did not participate in fitting the S-N curve. Therefore, the valid data of the other 20 bolts were used to fit the power multiplier S-N curves. Taking the stress amplitude as the parameter, the constant amplitude power regression curve and fatigue S-N curve are presented in Figure 8 and Figure 9, respectively, where the logarithmic equation for the corresponding part of the oblique line of the S-N curve in Figure 9 can be developed as Equation (7).
lg N = 32.365 11.419 lg Δ σ
It can be seen from Figure 8 and Figure 9 that the fatigue life of the specimens is relatively scattered at the same stress amplitude, but in total the fitting correlation coefficient of the bolt test data is highly satisfied, the value of which is about 0.8. Moreover, the test data follow the trend that the lower the stress range, the longer the fatigue life. Additionally, by calculating the standard deviation of fatigue test data, we can acquire the S-N curve equation under 97.72% survival probability, as shown in Equation (8).
lg N = 32.365 11.419   lg Δ σ 2 × 0.141

4. The Design Method for Constant Amplitude Fatigue Based on the Nominal Stress

4.1. The Establishment of the Formula

The nominal stress method takes the nominal stress of the parts as the parameter. Through a lot of fatigue tests, the fatigue S-N curves of different structural details are established, so as to design the fatigue strength or fatigue life of the structure. The high cycle fatigue problem mainly involves this method. At present, the nominal stress amplitude method is still the representative fatigue design and checking method in the steel structure design specifications of various countries. Therefore, we used the nominal stress amplitude as the control parameter, establishing the allowable stress amplitude fatigue design method of M24 twisted-shear high-strength bolts under the condition of full pretension. The method can be applied in practical engineering and check the fatigue strength of M24 twisted-shear high-strength bolts.
The calculating formula with the nominal stress amplitude as the design parameter is as follows:
Δ σ [ Δ σ ]
[ Δ σ ] = C N 1 / β

4.2. Application of The Formula

According to the fatigue S-N curve fitting formula, the value of the fatigue design parameter β is 11.419, and the value of the fatigue design parameter C is 12.106 × 1031. It can be seen that when the fatigue life of the bolt is 5 × 106, the value of normal amplitude fatigue limit Δ σ 5 × 10 6 is 167.0 MP, and when the fatigue life of the bolt is 2 × 106, the value of the allowable stress amplitude Δ σ 2 × 10 6 is 187.0 MP.

5. Estimating the Fatigue Life of M24 High-Strength Bolts Based on Broken Mechanics

5.1. Parameter Determination

The values of the parameters are shown in Table 9.

5.2. Estimation of Fatigue Life of M24 Twisted-Shear High-Strength Bolt

According to the fatigue crack extension parameters determined above, the fatigue life of M24 high-strength bolts is estimated based on the Paris formula, and the results are listed in Table 10, Table 11 and Table 12.
According to the comparison of the predicted life and the test life in the tables above, it is basically feasible to estimate the fatigue life of high-strength bolts by using the Paris formula, which can generally reflect the changing trend of fatigue life.

6. Results and Discussion

6.1. Influence of the Bolts’ Pretension on the Fatigue Strength

In existing fatigue performance research of M24 high-strength bolts [13], with the help of an MTS fatigue test machine, a normal amplitude fatigue test on 21 M24 high-strength large hexagon head bolts that were of 8.8 grade and made of 35 K steel was carried out. The torque value of the pretension force put on the bolt in the test was from 230 to 360 N·m. Test loading stress ratio R was equal to 0.5, σ max was from 180 to 460, increasing by 10 MP every time to 300 MP and adding 20 MP per level from 300 MP. σ min was from 90 to 150, increasing by 5 MP to 150 MP, and adding 20 MP per level from 150 MP. The constant stress amplitude fatigue of M24 high-strength large hexagon head bolts for fabricated steel structures was compared. The results of the constant amplitude fatigue test are shown in Table 13.
In existing fatigue performance research of M24 high-strength bolts [14], the constant amplitude fatigue test of 14 M24 high-strength hexagon head bolts with the help of an MTS fatigue test machine was completed, in which the material (ML20MnTiB) and strength grade (10.9) of the bolts were exactly the same as those of the test in this paper. The torque value of the pretension force put on the bolt in the test was from 200 to 300 N·m, and the test loading stress ratio R was equal to 0.64. The results of normal amplitude fatigue tests in the literature are listed in Table 14.
In order to compare the constant amplitude fatigue performance of M24 high-strength bolts under different conditions, the relationship between the stress range and fatigue life was investigated. Taking the nominal stress amplitude as the parameter, the power regression curve and S-N curve were established in the same coordinate system, as shown in Figure 10 and Figure 11.
Combined with the data in the fatigue test process analysis in Table 5, Table 6, Table 7 and Table 8 and Table 12, Table 13 and Table 14, taking the stress amplitude as the parameter, the constant amplitude power regression curve and fatigue S-N curve are presented in Figure 10 and Figure 11, respectively, where the logarithmic equation for the corresponding part of the oblique line of the S-N curve in Figure 11 can be developed as the first and the second equation in Table 16.
As can be seen above, the following conclusions can be drawn:
  • The grade 10.9 M24 twisted-shear high-strength bolt has a longer fatigue life, while the grade 8.8 M24 large hexagonal bolt has the shortest fatigue life;
  • Through comparing the test results of the M24 twisted-shear high-strength bolt with 100% pretension and of grade 10.9 and the grade 8.8 M24 large hexagonal bolt that only experienced 20~40% of the pretension torque value, it is seen that the pretension force of the bolt will have a great impact on the fatigue strength. The higher the value of the pretension force, the higher the fatigue strength of the bolt.

6.2. Influence of Bolt Diameter on Fatigue Strength

In existing fatigue performance research of M20 twisted-shear high-strength bolts [24,25], the material (ML20MnTiB) and strength grade (10.9) used in this test are exactly the same as the bolts tested, and the test loading stress ratio R is equal to 0.1. The value range of the largest stress is 350–550 MPa. The value range of the smallest stress is 35–55 MPa, with both showing a gradual decreasing trend. However, the fatigue life becomes longer and longer. The maximum value is 1,021,264 N/time; the minimum is 28,103 N/time. The results of normal amplitude fatigue tests in the literature are listed in Table 15.
In order to compare the constant fatigue performance of M24 and M20 twisted-shear high-strength bolts under full pretension, the double-log S-N curve is made in the same coordinate system according to the fatigue test data in Table 5, Table 6, Table 7 and Table 8 and in Table 15, as is shown in Figure 12, and the logarithmic equation for the corresponding part of the oblique line of the S-N curve is developed as the third equation in Table 16.
The constant amplitude fatigue S-N curve equations of the 8.8-grade M24 high-strength large hexagonal head bolt, the 10.9-grade M24 high-strength large hexagonal head bolt, and M20 torsion-shear bolt were obtained by regression fitting, as shown below.
As can be seen above, the following conclusions can be drawn:
  • Under full pretension, the fatigue test data of the M20 twisted-shear high-strength bolt have higher values than those of the M24 bolt.
  • Under the guaranteed probability of 97.72%, the stress amplitude of the M20 twisted-shear high-strength bolt corresponding to 2 million fatigue life is about 278.0 MPa, which is greater than the stress amplitude, the value of which is 181.0 MPa for the M24 bolt. It was indicated that under the same stress amplitude the M20 twisted-shear high-strength bolt has a longer fatigue life than the M24 twisted-shear high-strength bolt.
  • The fatigue strength will decrease when the bolt diameter increases. The reason is that, due to the influence trend that the bolt diameter has on the fatigue strength, when the diameter of the bolt increases, the concentration of the stress between the thread and the bolt will be exacerbated; meanwhile, some defects or impurities will occur during the process of heat treatment.

7. Conclusions

This research included a total of 25 constant amplitude fatigue experiments to study the fatigue performance of M24 twisted-shear high-strength bolts. The design method for constant amplitude fatigue based on the nominal stress was established. In order to evaluate the fatigue performance of M24 twisted-shear high-strength bolts exactly, comparisons between fatigue test data obtained from M24 high-strength bolts of grades 8.8 and 10.9 with a large hexagon head under 20–40% pretension force and M20 bolts under full pretension force were completed. The following conclusions could be drawn based on the findings from the above experiments.
  • Fatigue failure of all M24 twisted-shear high-strength bolts in the test occurred at the root of the high-strength bolt thread, and among them most bolts were damaged at the first circle of the thread between the nut and the bolt, where there was a serious stress concentration, and the fatigue gap effect was significant.
  • The constant amplitude fatigue S-N curve was obtained by test data fitting and the corresponding S-N curve equation of M24 twisted-shear high-strength bolts with the stress range as the design parameter, and the fitting correlation coefficient of the test data was about 0.8. Under the guaranteed rate of 97.72%, the allowable stress amplitude of 5 million fatigue life is about 167.0 MPa; that of 2 million fatigue life is about 181.0 MPa.
  • According to the fatigue S-N curve fitting formula, the value of the fatigue design parameter is 11.419, and the value of the fatigue design parameter C is 12.106 × 1031. It can be seen that when the fatigue life of the bolt is 5×106, the value of normal amplitude fatigue limit is 167.0 MP, and when the fatigue life of the bolt is 2 × 106, the value of the allowable stress amplitude is 187.0 MP.
  • It is basically feasible to estimate the fatigue life of high-strength bolts by using the Paris formula, which can generally reflect the changing trend of fatigue life.
  • M24 twisted-shear high-strength bolts with 100% pretension force had better performance in the specified stress range. Under the 97.72% survival probability, the fatigue strength of M24 pretension force high-strength bolts was 1.86 times and 1.71 times that of the 8.8-grade M24 and 10.9-grade M24 large hexagonal head bolts, respectively.
  • By comparing the test results of M24 and M20 bolts under full pretension, it is seen that when the diameter of the bolt decreases, the fatigue strength of the bolt will reduce.

8. Future Works

In the future, this research will provide more and stronger data for further fatigue life theory analysis of other twisted-shear high-strength bolts of different diameters and grades. It is necessary that more tests on twisted-shear high-strength bolts of different diameters and grades are carried out in order to predict the fatigue life of steel structures constituted by twisted-shear high-strength bolt connections.

Author Contributions

Conceptualization, H.L.; Data curation, R.X.; Formal analysis, R.X. and B.Q.; Investigation, R.X. and B.Q.; Methodology, R.X.; Software, R.X.; Writing—Original draft, R.X.; Writing—Review and Editing, R.X. and H.L.; Funding acquisition, H.L. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by National Nature Science Foundation of China, grant number No. 51578387.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data is contained within the article.

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

σ0.2measured value of the offset yield strength
σbmeasured value of the yield strength
Emeasured value of the elastic modulus
δmeasured value of elongation rate
σmaxthe maximum stress
σminthe minimum stress
∆σthe loading stress range
σmthe average stress
fythe yield strength
Rthe stress ratio (the ratio of minimum stress to maximum stress)
Nfatigue life
Cundetermined parameter
βundetermined parameter
a0initial crack length
accritical crack length
αstress intensity factor
Cmaterial parameter
mmaterial parameter

References

  1. Sun, H.X. Overview on the development of fatigue research and the fatigue fracture mechanism. Glob. Mark. 2016, 25, 101. [Google Scholar]
  2. Hobbs, J.W.; Burguete, R.L.; Heyes, P.F.; Patterson, E.A. Effect of eccentric loading on the fatigue performance of high tensile bolts. Int. J. Fatigue 2000, 22, 531–538. [Google Scholar] [CrossRef]
  3. Novoselac, S.; Kozak, D. Fatigue damage assessment of bolted ioint under different preload. New Trends Fatigue Fract. 2014, 14, 93–109. [Google Scholar]
  4. Nan, Z.S.; Li, H.F.; Luo, J. Study on the mechanism of ultra-low cycle fatigue failure about steel LY 100 with low yielding point considering welding influence. Prog. Build. Steel Struct. 2008, 20, 12–17+66. [Google Scholar]
  5. Feng, X.J.; Lin, X.S.; Pan, W. Fatigue performance of bolt ball node grid under the action of suspension crane. J. Archit. 1995, 16, 3–13. [Google Scholar]
  6. Farrahi, G.H.; Habibi, N. Experimental evaluation of the effect of thread pitch on fatigue life of bolts. Int. J. Fatigue 2005, 27, 189–196. [Google Scholar]
  7. Lei, H.G.; Pei, Y.; Liu, L.J. Finite element analysis on fatigue notch factor of high strength bolts. Eng. Mech. 2008, 1, 49–53. [Google Scholar]
  8. Yan, Y.J.; Lei, H.G.; Jiao, J.F. Establishment of fatigue calculation method on high strength bolt in the bolt ball node grid. J. Archit. 2010, 31, 92–97. [Google Scholar]
  9. Lei, H.G.; Liu, X.J.; Jiao, J.F. Study on variable amplitude fatigue test and fatigue life estimation of high strength bolts in the the bolt ball node grid. J. Archit. 2010, 31, 98–102. [Google Scholar]
  10. Yang, X. Test and Theoretical Study on Fatigue Performance of High Strength Bolts M30 and M39 in the Bolt Ball Node Grid. Ph.D. Thesis, Taiyuan University of Technology, Taiyuan, China, 2017. [Google Scholar]
  11. Saranik, M.; Jrzrquel, L.; Lenoir, D. Experimental and numerical study for fatigue life prediction of bolted connection. Procedia Eng. 2013, 66, 354–368. [Google Scholar] [CrossRef] [Green Version]
  12. Lei, H.G. The Theoretical and Experimental Study on the Fatigue Performance of the High-Strength Bolt Connection in the Network Frame Structure with Bolt Sphere Node. Ph.D. Thesis, Taiyuan University of Technology, Taiyuan, China, 2008. [Google Scholar]
  13. Xin, H.H.; Jose Correia, A.F.O.; Veljkovic, M. Three-dimensional fatigue crack propagation simulation using extended finite element methods for steel grades S355 and S690 considering mean stress effects. Eng. Struct. 2021, 227, 111414. [Google Scholar] [CrossRef]
  14. Jiao, J.; Liu, Z.; Guo, Q.; Liu, Y.; Lei, H. Constant-amplitude fatigue behavior of M24 high-strength bolt of end-plate flange connection. Structures 2021, 34, 2041–2053. [Google Scholar] [CrossRef]
  15. Huang, W.P. Test and Theoretical Study on the Fatigue Performance of M24 High Strength Bolt in Prefabricated Steel Structure. Ph.D. Thesis, Taiyuan University of Technology, Taiyuan, China, 2019. [Google Scholar]
  16. Guo, H.C.; Wan, J.H.; Liu, Y.H. The fatigue performance test study of Q690D high strength steel bolt connection. J. Civ. Eng. 2018, 51, 20–26. [Google Scholar]
  17. Bai, Y.; Nardi, D.C.; Zhou, X.; Picon, R.A.; Florez-Lopez, J. A new comprehensive model of damage for flexural subassemblies prone to fatigue. Comput. Struct. 2021, 256, 106639. [Google Scholar] [CrossRef]
  18. Niu, X.; Zhu, S.P.; He, J.C.; Liao, D.; Correia, J.A.; Berto, F.; Wang, Q. Defect tolerant fatigue assessment of AM materials: Size effect and probabilistic prospects. Int. J. Fatigue 2022, 160, 106884. [Google Scholar] [CrossRef]
  19. Li, X.K.; Zhu, S.P.; Liao, D.; Correia, J.A.; Berto, F.; Wang, Q. Probabilistic fatigue modelling of metallic materials under notch and size effect using the weakest link theory. Int. J. Fatigue 2022, 159, 106788. [Google Scholar] [CrossRef]
  20. GB/T3632-2008; Torsional Shear High Strength Bolt Link for Steel Structure. The Standardization Administration of China, General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China: Beijing, China, 2008.
  21. GB/50017-2017; Standard for Design of Steel Structure. Ministry of Housing and Urban-Rural Development, PRC, General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China: Beijing, China, 2017.
  22. GB/T1591-2018; High-Strength Low Alloy Structural Steels. The Standardization Administration of China, The State Administration for Market Regulation: Beijing, China, 2018.
  23. GB/T228.1-2010; Metallic Materials-Tensile Testing-Part 1: Method of Test at Room Temperature. The Standardization Administration of China, General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China: Beijing, China, 2010.
  24. GB/T3075-2008; Metallic Materials-Tensile Testing-Axial-Force-Controlled Method. The Standardization Administration of China, General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China: Beijing, China, 2008.
  25. Shen, Y. Experimental Study on Fatigue Performance of M20 High Strength Torsion Shear Screw Shaft Drawing for Prefabricated Steel Structure. Ph.D. Thesis, Taiyuan University of Technology, Taiyuan, China, 2022. [Google Scholar]
Figure 1. The high-strength bolt connection.
Figure 1. The high-strength bolt connection.
Applsci 13 04296 g001
Figure 2. T-type connectors.
Figure 2. T-type connectors.
Applsci 13 04296 g002
Figure 3. Standard tensile specimen for M24 torsional shear-type high-strength bolt.
Figure 3. Standard tensile specimen for M24 torsional shear-type high-strength bolt.
Applsci 13 04296 g003
Figure 4. Schematic diagram of test loading.
Figure 4. Schematic diagram of test loading.
Applsci 13 04296 g004
Figure 5. Comparison of M24 torsional shear-type bolt before and after pretightening application.
Figure 5. Comparison of M24 torsional shear-type bolt before and after pretightening application.
Applsci 13 04296 g005
Figure 6. A general view of fatigue test loading for M24 high-strength bolts.
Figure 6. A general view of fatigue test loading for M24 high-strength bolts.
Applsci 13 04296 g006
Figure 7. Fatigue failure of specimens.
Figure 7. Fatigue failure of specimens.
Applsci 13 04296 g007
Figure 8. The power regression S-N curve with the stress range as parameter.
Figure 8. The power regression S-N curve with the stress range as parameter.
Applsci 13 04296 g008
Figure 9. S-N curve of M24 high-strength bolts obtained from the tests.
Figure 9. S-N curve of M24 high-strength bolts obtained from the tests.
Applsci 13 04296 g009
Figure 10. Comparing fatigue test results of three bolts.
Figure 10. Comparing fatigue test results of three bolts.
Applsci 13 04296 g010
Figure 11. Comparing fatigue test results of three bolts (double logarithmic S-N curve).
Figure 11. Comparing fatigue test results of three bolts (double logarithmic S-N curve).
Applsci 13 04296 g011
Figure 12. Comparison of fatigue test data of M24 and M20 bolts.
Figure 12. Comparison of fatigue test data of M24 and M20 bolts.
Applsci 13 04296 g012
Table 1. High-strength bolt type, performance grade, and related specifications.
Table 1. High-strength bolt type, performance grade, and related specifications.
TypeMaterial or Performance GradeStandard
torsion-shear high-strength bolt connectionbolt10.9STorsion-shear High-strength Bolt Link for Steel Structure
(GB/T 3632-2008) [19]
nut10H
gasket35 steel/45 steel
Table 2. Test results for high-strength bolts.
Table 2. Test results for high-strength bolts.
No.Strength (MPa)Modulus of Elasticity (GPa)Extensibility δ ¯
σ 0.2 σ 0.2 ¯ σ b σ b ¯ E E ¯
a1008.410291084.41106.5208.9207.913.4
b10401117.8209.1
c1038.61117.2205.6
Table 3. Details of testing program.
Table 3. Details of testing program.
Level σ m a x   ( MP ) Δ σ   ( MP ) NumberLevel σ m a x   ( MP ) Δ σ   ( MP ) Number
L14001602L65152062
L24751902L75252102
L34851941L85502209
L45002002L95752302
L5512.52051L106002402
Table 4. Fatigue failure mode for high-strength bolts.
Table 4. Fatigue failure mode for high-strength bolts.
Model No.Fatigue Fracture CharacteristicIllustration
1Fatigue fracture occurred at the first circle of the bite between the bolt rod and the nut, and the number of bolts where fatigue damage occurred accounts for about 85% of the total number of specimens. It is the main form of damage in this fatigue test. The reason is that the fixing effect of the nut leads to the thread gap root of the first circle between the nut and the thread has a serious stress concentration, the fatigue notch effect is significant, and the initial fatigue crack easily occurs.Applsci 13 04296 i001
2There is only one bolt fatigue failure which is of this type, which is far away from the thread bottom where the nut meshes, and it destroyed the first circle of the thread of the transition area between the bolt rod (smooth part) and the thread.Applsci 13 04296 i002
3The bolts were not completely broken, but some obvious cracks appeared in the thread, which seriously affected the bearing capacity of the bolts. There were three bolts with this damage mode. If the loading continued, the bolt also broke at the thread.Applsci 13 04296 i003
Table 5. Constant amplitude fatigue test results of M24 torsional shear-type high-strength bolt with pretension ( σ m a x = 400–500 MP).
Table 5. Constant amplitude fatigue test results of M24 torsional shear-type high-strength bolt with pretension ( σ m a x = 400–500 MP).
No.Loading Stress/MPaStress Amplitude/MPaFatigue Life/Time
σ m a x
σ m i n
σ m
R
Δ σ
N
M24-14002403200.61605,100,006
M24-24002403200.61605,100,006
M24-34752853800.61902,273,480
M24-44752853800.61902,352,282
M24-54852913880.6194751,375
M24-65003004000.62001,221,394
M24-75003004000.62001,298,395
Table 6. Constant amplitude fatigue test results of M24 torsional shear-type high-strength bolt with pretension ( σ m a x = 512.5–525 MP).
Table 6. Constant amplitude fatigue test results of M24 torsional shear-type high-strength bolt with pretension ( σ m a x = 512.5–525 MP).
No.Loading Stress/MPaStress Amplitude/MPaFatigue Life/Time
σ m a x
σ m i n
σ m
R
Δ σ
N
M24-8512.5307.54100.62051,546,630
M24-95153094120.6206492,189
M24-105153094120.6206492,189
M24-115253154200.6210535,942
M24-125253154200.6210567,354
Table 7. Constant amplitude fatigue test results of M24 torsional shear-type high-strength bolt with pretension ( σ m a x = 550 MP).
Table 7. Constant amplitude fatigue test results of M24 torsional shear-type high-strength bolt with pretension ( σ m a x = 550 MP).
No.Loading Stress/MPaStress Amplitude/MPaFatigue Life/Time
σ m a x
σ m i n
σ m
R
Δ σ
N
M24-135503304400.6220153,563
M24-145503304400.6220205,678
M24-155503304400.6220196,329
M24-165503304400.6220370,241
M24-175503304400.6220457,271
M24-185503304400.6220457,271
M24-195503304400.6220642,275
M24-205503304400.6220642,275
M24-215503304400.6220441,443
Table 8. Constant amplitude fatigue test results of M24 torsional shear-type high-strength bolt with pretension ( σ m a x = 575–600 MP).
Table 8. Constant amplitude fatigue test results of M24 torsional shear-type high-strength bolt with pretension ( σ m a x = 575–600 MP).
No.Loading Stress/MPaStress Amplitude/MPaFatigue Life/Time
σ m a x
σ m i n
σ m
R
Δ σ
N
M24-225753454600.6230282,422
M24-235753454600.6230282,422
M24-246003604800.6240195,186
M24-256003604800.6240214,782
Table 9. The value of parameters.
Table 9. The value of parameters.
Parametera0ac (mm)αCm
0.01 mm, 0.02 mm, 0.05 mm21.191.12157.04 × 10−123
Table 10. Estimated fatigue life of M24 high-strength bolt (a0 = 0.01 mm).
Table 10. Estimated fatigue life of M24 high-strength bolt (a0 = 0.01 mm).
No. σ m a x / MPa σ m i n / MPa Δ σ n / MPa Predicted Life/TimeTest Life/Time
M24-14002401602,731,7215,100,006
M24-24002401602,731,7215,100,006
M24-34752851901,631,3062,273,480
M24-44752851901,631,3062,352,282
M24-54852911941,532,467751,375
M24-65003002001,398,6411,221,394
M24-75003002001,398,6411,298,395
M24-8512.5307.52051,298,7771,546,630
M24-95153092061,279,955492,189
M24-105153092061,279,955492,189
M24-115253152101,208,199535,942
M24-125253152101,208,199567,354
M24-135503302201,050,820153,563
M24-145503302201,050,820205,678
M24-155503302201,050,820196,329
M24-165503302201,050,820370,241
M24-175503302201,050,820457,271
M24-185503302201,050,820457,271
M24-195503302201,050,820642,275
M24-205503302201,050,820642,275
M24-215503302201,050,820441,443
M24-22575345230919,629282,422
M24-23575345230919,629282,422
M24-24600360240809,399195,186
M24-25600360240809,399214,782
Table 11. Estimated fatigue life of M24 high-strength bolt (a0 = 0.02 mm).
Table 11. Estimated fatigue life of M24 high-strength bolt (a0 = 0.02 mm).
No. σ m a x / MPa σ m i n / MPa Δ σ n / MPa Predicted Life/TimeTest Life/Time
M24-14002401601,913,8515,100,006
M24-24002401601,913,8515,100,006
M24-34752851901,142,8972,273,480
M24-44752851901,142,8972,352,282
M24-54852911941,073,650751,375
M24-6500300200979,8921,221,394
M24-7500300200979,8921,298,395
M24-8512.5307.5205909,9271,546,630
M24-9515309206896,740492,189
M24-10515309206896,740492,189
M24-11525315210846,467535,942
M24-12525315210846,467567,354
M24-13550330220736,207153,563
M24-14550330220736,207205,678
M24-15550330220736,207196,329
M24-16550330220736,207370,241
M24-17550330220736,207457,271
M24-18550330220736,207457,271
M24-19550330220736,207642,275
M24-20550330220736,207642,275
M24-21550330220736,207441,443
M24-22575345230644,295282,422
M24-23575345230644,295282,422
M24-24600360240567,067195,186
M24-25600360240567,067214,782
Table 12. Estimated fatigue life of M24 high-strength bolt a0 = 0.05 mm.
Table 12. Estimated fatigue life of M24 high-strength bolt a0 = 0.05 mm.
No. σ m a x / MPa σ m i n / MPa Δ σ n / MPa Predicted Life/TimeTest Life/Time
M24-14002401601,188,1305,100,006
M24-24002401601,188,1305,100,006
M24-3475285190709,5172,273,480
M24-4475285190709,5172,352,282
M24-5485291194666,528751,375
M24-6500300200608,3231,221,394
M24-7500300200608,3231,298,395
M24-8512.5307.5205564,8881,546,630
M24-9515309206556,701492,189
M24-10515309206556,701492,189
M24-11525315210525,492535,942
M24-12525315210525,492567,354
M24-13550330220457,042153,563
M24-14550330220457,042205,678
M24-15550330220457,042196,329
M24-16550330220457,042370,241
M24-17550330220457,042457,271
M24-18550330220457,042457,271
M24-19550330220457,042642,275
M24-20550330220457,042642,275
M24-21550330220457,042441,443
M24-22575345230399,982282,422
M24-23575345230399,982282,422
M24-24600360240352,039195,186
M24-25600360240352,039214,782
Table 13. Constant amplitude fatigue test data of M24 high-strength bolts with large hexagon head.
Table 13. Constant amplitude fatigue test data of M24 high-strength bolts with large hexagon head.
No.Stress/MPaStress Amplitude/MPaFatigue Life/Time
σ m a x σ m i n RThe Torque Value of the Pretension Force/(N·m)∆σN
1180900.5300902,426,465
2190950.5360952,477,335
32001000.53001002,791,911
42101050.52301051,748,722
52201100.53001101,422,068
62301150.52301151,152,669
72401200.5330120818,742
82501250.5250125532,491
92601300.5330130684,474
102701350.5270135778,867
112801400.5330140296,540
122901450.5190145539,048
133001500.5360150523,784
143201600.5360160385,283
153401700.5360170189,234
163601800.5240180190,009
173801900.5240190130,256
184002000.5240200168,523
194202100.527021084,119
204402200.527022081,535
214602300.527023068,781
Table 14. Constant amplitude fatigue test data of M24 high-strength bolts with large hexagon head.
Table 14. Constant amplitude fatigue test data of M24 high-strength bolts with large hexagon head.
No.Stress/MPaStress Amplitude/MPaFatigue Life/Time
σ m a x σ m i n σ m R∆σN
110006408200.6436021,500
211337259290.6440812,800
34302783540.64155411,700
44502883690.64162319,000
5470300.8385.40.64169.2306,900
6490313.6401.80.64176.4299,200
78005126560.6428846,000
86504165330.64234113,000
96003844920.64216159,300
105503524510.64198179,200
114002563280.64144668,200
123502242870.641261,305,600
13370236.8303.40.64133.2732,700
14360230.4295.20.64129.6915,600
Table 15. Constant amplitude fatigue life of M20 bolts under full pretension force.
Table 15. Constant amplitude fatigue life of M20 bolts under full pretension force.
No.Fatigue Life/TimeNo.Fatigue Life/Time
NN
M20-128,103M20-7106,049
M20-232,223M20-8124,244
M20-334,656M20-9293,280
M20-449,162M20-101,021,264
M20-579,504M20-11602,672
M20-687,079M20-121,580,019
Table 16. Constant amplitude fatigue S-N curve equation of M24 and M20 high-strength bolts with large hexagon head.
Table 16. Constant amplitude fatigue S-N curve equation of M24 and M20 high-strength bolts with large hexagon head.
The Type of BoltEquationThe Stress Amplitude/MP (2 Million Fatigue Life; the Reliability Level of 97.72%)
10.9-grade M24 twisted-shear bolt lg N = 32.365 11.419   lg Δ σ 2 × 0.141 167
8.8-grade M24 lg N = 14.697 4.188   lg Δ σ 2 × 0.106 90
10.9-grade M24 lg N = 13.821 3.720   lg Δ σ 2 × 0.056 98
M20 twisted-shear bolt lg N = 27.023 8.348   lg Δ σ 2 × 0.1535 278
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Xing, R.; Qiu, B.; Lei, H. Experimental Study on Fatigue Performance of M24 Twisted-Shear High-Strength Bolt for Assembled Steel Structure. Appl. Sci. 2023, 13, 4296. https://doi.org/10.3390/app13074296

AMA Style

Xing R, Qiu B, Lei H. Experimental Study on Fatigue Performance of M24 Twisted-Shear High-Strength Bolt for Assembled Steel Structure. Applied Sciences. 2023; 13(7):4296. https://doi.org/10.3390/app13074296

Chicago/Turabian Style

Xing, Rong, Bin Qiu, and Honggang Lei. 2023. "Experimental Study on Fatigue Performance of M24 Twisted-Shear High-Strength Bolt for Assembled Steel Structure" Applied Sciences 13, no. 7: 4296. https://doi.org/10.3390/app13074296