1. Introduction
Enterococcus belongs to a genus of commonly found bacteria with low pathogenicity and is relatively harmless when detected in healthy individuals. In people with reduced immune function,
Enterococcus can lead to serious infectious diseases, such as endocarditis or septicemia, which require treatment with antibiotics [
1,
2,
3]. However, increased antibiotic use has resulted in the emergence of drug-resistant strains, including those resistant to vancomycin, which has become a major problem. In sewage treatment plants in Japan, the currently used concentration of chlorine may not completely sterilize drug-resistant bacteria [
4]. This may lead to the propagation of resistance genes, thereby leading to the appearance of new strains of multidrug-resistant bacteria. Sterilization via ultraviolet irradiation and ozone are alternatives to chlorination; however, the required equipment is costly. Furthermore, the effectiveness of these methods is attenuated by turbidity, indicating that sufficient sterilization may not always be achieved.
In the present study, we proposed the use of impulse voltage as an alternative method of sterilization [
5]. This technique uses an electric field to physically disrupt bacterial cell membranes [
6,
7], thereby inactivating the bacteria itself [
8]. Since the experiments of Sale and Hamilton in 1967, a number of studies on impulse-voltage-mediated sterilization have been performed [
9,
10,
11,
12,
13,
14]. In the impulse voltage method, physical factors such as electric field and temperature distribution between electrodes, the orientation of bacteria to the electric field, and the nature of the medium as well as biological factors such as the cell cycle and membrane state affect the degree of membrane damage and response to damage. Until now, mostly bacteria that are likely to be detected in food, such as
E. coli and
Enterobacter, were subjected to sterilization by impulse voltage. To date, the authors have applied impulse voltage to vancomycin-resistant
Enterococcus faecium (
VRE) and achieved a reduction rate of >5 log. However, the temperature of the bacterial suspension was not controlled but increased by the energy of the impulse voltage [
15].
In addition, since sterilization by impulse voltage causes intracellular fluid to flow out due to membrane damage, we predicted that intracellular ions might flow out and change the conductivity of the entire bacterial suspension. In order to determine the number of sterilized bacteria, it is necessary to know the number of viable bacteria. There are various methods for quantifying viable bacteria, such as the turbidity, plate culture, and polymerase chain reaction methods; however, these methods have disadvantages such as the time required for measurement and the high cost of the equipment. If the number of bacteria can be estimated by measuring conductivity, it may be possible to develop an inexpensive and simple method for quantifying bacteria, although its use is limited to sterilization by impulse voltage. Furthermore, the temperature was not constant but increased according to the number of times impulse voltage was applied. In this study, we clarified the sterilizing effect of impulse voltage on VRE when temperature was controlled, focused on the change in conductivity of the bacterial suspension after impulse voltage was applied, and investigated its relationship with the rate of sterilization.
2. Materials and Methods
2.1. Target Bacteria
VRE (Gram-positive bacterium) strain ATCC 51559, which possesses the
vanA gene, was used as a representative antibiotic-resistant bacterium in this study.
VRE is listed as a serious threat in the CDC publication “Antibiotic Resistance Threats in the United States” and is considered one of the most alarming threats to public health.
VRE carries the
vanA gene. These resistance genes are located on plasmids and can easily undergo horizontal gene transfer [
16].
2.2. Design of an Impulse Voltage Generator
Figure 1 shows the circuit diagram of the impulse voltage generator that uses a transformer. The circuit configuration consists of a primary capacitor (
C0 = 1.67 µF), SI (saturable inductor) device, transformer, and 10 silicon-insulated gate bipolar transistor processes (Si-IGBTs; IXYS, IXYL60N447) connected in parallel. The output voltage (
Vout) was applied to the load resistor (
R) connected in parallel with the capacitor (
C1 = 25 µF). The Si-IGBT is a discrete type of device with a rated voltage (
VCES) of 4.5 kV and an instantaneous maximum current (<1 ms; I
CM) of 680 A.
SI, which is comprised of windings on the iron core, was used to connect the current to the IGBTs in a parallel and uniform manner. In the current procedure, switching was controlled via an inductance change when the iron core was saturated and unsaturated; this is also known as a magnetic switch or saturable inductor. Therefore, permeability at saturation and unsaturation significantly affects the switching performance. Additionally, high-saturation magnetic flux density and slight core loss are required. In this section, the generation of
I1 was delayed using SI, and
I1 flowed after all Si-IGBTs connected in parallel were turned on, which enabled parallelization. The saturation time t
s (in µs) when a voltage Va (in V) is applied to a magnetic material with a running cross-sectional area Ae (in mm
2), saturation flux density Bs (in mT), and number of turns N are calculated using the following equation [
17]:
From the above equation, the delay time is directly proportional to the saturation flux density and number of turns of the magnetic material and inversely proportional to the applied voltage. SI used in this study was an iron core made of iron-based nanocrystalline alloy (Hitachi Metals, FT-3H, Bs = 1.23 mT) with a cross-sectional area of 1983 mm2. The number of turns was set to 15. The primary and secondary windings in the transformer were routed at equal intervals to equalize the magnetic flux distribution in the transformer, prevent leakage inductance, and increase the coupling factor.
Figure 2 shows the gate circuit of the Si-IGBT. A pulse signal with a signal voltage of 5 V from a function generator was input to a photocoupler (Toshiba, TLP350(F)); the pulse signal was amplified to 22 V. The amplified pulse signal was transmitted to each Si-IGBT through the gate resistor
Rg, which was set to 8.0 Ω for the current experiment.
2.3. The Shape of Electrodes for Impulse Voltage Application
Figure 3 shows the shape of the electrodes used for bacterial and gene sterilization, including a cross-sectional diagram of the apparatus. The structure was that of a coaxial cylinder; stainless steel was used for the conductors, and polyvinyl chloride was used for the insulators. The inner conductor had a diameter of 8 mm, the outer conductor had a bore of 14.4 mm, and the space between the electrodes measured 3.2 mm. The apparatus was wired, with the inner conductor as the high-tension side and the outer conductor as the ground. The bacterial suspension was introduced into the space between the electrodes, and an impulse voltage was applied. The impulse voltage generator was developed using magnetic materials (Hitachi Metals, FT-3H, Bs = 1.23 mT) and semiconductor switches. The operating frequency was 200 Hz, and the impulse voltage was applied with a pulse width (full width at half maximum) of 6.9 µs or 1.7 µs.
2.4. Preparation of a Suspension and Bacterial Count
VRE at the late stage of logarithmic growth, i.e., when it is very active, were used for sterilization experiments where impulse voltage was applied. The optimum incubation time of 12–14 h was determined based on the
VRE growth curve [
15]. The strain was inoculated into Todd–Hewitt broth (Difco) supplemented with 128 µg/mL of vancomycin and incubated for 12–14 h at 37 °C ± 1.0 °C in a rotary shaker (120 rpm). Next, 5 mL of the precultured
VRE strain was centrifuged at 4000×
g for 5 min, and the supernatant was removed. The bacterial pellet was washed twice using 10 mL of sterile ultrapure water. The pellet was then suspended in 40 mL of sterile ultrapure water. The bacterial suspension’s absorbance was measured at 600 nm (OD
600) using a spectrophotometer (AE-350, ERMA). Finally, the suspension containing
VRE was adjusted to approximately 8.0 × 10
5 CFU/mL and 8.0 × 10
3 CFU/mL via dilution based on the calibration curve (OD
600 absorbance vs.
VRE count). The suspension was adjusted to approximately 8.0 × 10
9 CFU/mL because the change in conductivity was small when the conductivity was measured. The suspension was stored at 25 °C ± 1.0 °C until use in the application experiment. The culturable
VRE of each sample was counted using the spread plate method and Chromocult Enterococci Agar (Merck) plates. Samples predicted to have high bacterial concentrations were diluted with sterile phosphate-buffered saline; 100 µL of the sample or its prepared dilutions were inoculated on agar plates in triplicate and incubated at 35.0 °C ± 1.0 °C for 20–24 h. This was repeated five times for each condition. The sterilization rate (N) was expressed as the logarithm of the ratio of the number of bacteria (C
0) before application to the number of bacteria (C) after application, as shown in Equation (2).
2.5. Application of Impulse Voltage to the Bacterial Suspension
Impulse voltages with initial voltages of 0 kV, 1.5 kV, 4.5 kV, and 7.5 kV were applied to the bacterial suspension with an operating frequency of 200 Hz and a pulse width of 6.9 μs or 1.7 μs. The concentration of the suspension was 8.0 × 105 CFU/mL and 8.0 × 103 CFU/mL, and the application time was up to 10 min. The temperature change observed when the concentration of the suspension was 8.0 × 105 CFU/mL was also measured.
2.6. Temperature Control of the Bacterial Suspension
Sterilization via application of impulse voltage was attempted after maintaining a constant temperature of the bacterial suspension inside the electrodes by cooling the outer conductor with circulating water whose temperature was controlled by a chiller. The concentration of bacteria was set to 5.0 × 105 CFU/mL to clarify the effects of the impulse voltage versus the resulting increase in temperature. To clarify the relationship between electrical conductivity and bactericidal activity, a dilution of 8.0 × 109 CFU/mL was also used. The temperature was adjusted to 20 °C, 40 °C, or 50 °C. The changes in the sterilization rate at an applied voltage of 7.5 kV, pulse width of 6.9 μs, and frequency of 200 Hz were measured via the colony method. In addition, the change in the sterilization rate without the impulse voltage was confirmed.
2.7. Conductivity Measurement of the Bacterial Suspension
Change in electrical conductivity when an impulse voltage was applied to a bacterial suspension of 8.0 × 109 CFU/mL was measured. The conductivity was measured using a submersible electrical conductivity meter (Xylem, model 3200) at temperatures of 20 °C, 40 °C, and 50 °C of the bacterial suspension after application. Next, under the same bacterial concentration and electrical conditions mentioned in the previous section, an impulse voltage was applied to the bacterial suspension of VRE, and the conductivity was measured.
2.8. Statistical Analysis
Statistical analysis was conducted in Excel 2021 (Microsoft). To determine the relationships between each reduction ratio of VRE count and conductivity, with each electrical parameter (application time, voltage, and pulse width), the multiple regression analysis was carried out using VRE counts or conductivity as a response variable, and initial voltage, frequency, and pulse width as explanatory variables. The p-values were computed at a confidence level of 95%.
4. Discussion
Considering the impedance of the bacterial suspension, the voltage and current waveforms match the waveforms shown in
Figure 5 and
Figure 8, and the bacterial suspension has a majority of real (resistance) components. Baba et al. analyzed the electric field distribution at a frequency of 2 MHz for a liquid with higher conductivity and found that the electric field distribution is independent of the dielectric constant and is determined only by the conductivity [
18]. The pulse waveform applied in this experiment is in the order of μs (a few kHz), which indicates that the target bacterial liquid is resistive.
Figure 4 and
Figure 6 show that there was no difference in the sterilization rate at voltages of 7.5 kV and 1.5 kV, but the difference at 4.5 kV was significant. With a pulse width of 1.7 μs, the sterilization rate reached 6.0 log within 10 min of application, whereas with a pulse width of 6.9 μs, the sterilization rate reached 6.0 log within 5 min. Gintautas et al. and Frey et al. stated that pulse widths that differ by ≥100 times have an impact on the sterilization rate. The comparison revealed that the pulse widths of the voltage waveforms used in this experiment differed only by approximately four times, which was small enough to ensure that no difference in the sterilization rate is expected [
19,
20,
21,
22,
23,
24]. However, when comparing the time required for the temperature of the bacterial suspension to reach 38 °C at a voltage of 4.5 kV, it was found that application times of 10 and 5 min were required at a pulse width of 1.7 μs and 6.9 μs, respectively. The rate of increase in temperature was approximately double, which is consistent with the rate of increase in the sterilization rate. It is assumed that this is the reason for the difference in sterilization effects. To understand the relationship between sterilization rate and electrical parameters at a bacterial concentration of 8.0 × 10
5 CFU/mL, multiple regression analysis was performed. The results are shown in
Table 1. The disinfection rate did not depend on the pulse width, and there was no significant difference (
p > 0.05). The correlation between the applied voltage and the application time was confirmed (
p < 0.05), and the correlation between the applied voltage and the application time was higher than that between the applied voltage and the application time.
The change in the temperature of the bacterial suspension caused by impulse voltage is an important factor for determining the effectiveness of sterilization rate [
25,
26]. If the pores created in the cell membrane by the pulsed electric field are larger than a certain size, the intracellular fluid will flow out and the bacteria will die. The state of the phospholipids that make up the cell membrane is temperature dependent. Furthermore, a higher temperature is associated with a weaker lipid aggregation state; consequently, the sterilization treatment becomes more effective [
25,
26]. Heat is reported to be a factor that inhibits the repair of pores in the cell membrane, which may further enhance the sterilizing effect produced by impulse voltage [
27,
28]. Changes in the sterilization rate for the bacterial suspension at a constant temperature demonstrate that (
Figure 10) a higher temperature of the bacterial suspension would lead to a higher sterilization rate. It has been reported that
E. faecium could not maintain gene expression at temperatures above 60 °C [
15]. In this experiment, the bacteria were inactivated even when the temperature of the bacterial suspension was <50 °C, which indicated that the death of the bacteria was not only caused by heat but also by the electric field. To understand the relationship between the temperature of the bacterial suspension, electrical parameters, and sterilization rate, we performed a multiple regression analysis based on the results of
Figure 10b as before. The results are shown in
Table 2. The temperature of the bacterial diluent and the application time were correlated with the sterilization rate (
p < 0.05). The correlation of the bacterial diluent with the temperature was higher than that with the applied voltage. This result is consistent with the above discussion of electrical parameters and disinfection rate.
Longer application times lead to proportional increases in the conductivity; furthermore, the higher the temperature of the bacterial suspension was, the higher the conductivity. When the temperature of the bacterial suspension was 40 °C and 50 °C, the rate of increase in conductivity was similar, and at 20 °C, the conductivity was lower than that at 40 °C. This change in conductivity was similar to the change in the sterilization rate shown in
Figure 10. Therefore, we analyzed the relationship between the sterilization rate and conductivity obtained in the previous experiment, and as shown in
Figure 12, there was a correlation between the sterilization rate and conductivity when the number of bacteria was ≥6.0 log. When a pore opens in the cell membrane due to the application of pulsed high voltage, intracellular fluid flows out. Through experiments, Gintautas et al. showed that the concentration of potassium ions leaked from the cell increases with increasing electric field strength that can perforate the cell membrane [
20]. In the present experiment, considering that the extracellular area was ultrapure water and the ion concentration was extremely low, the impulse voltage caused intracellular fluid ions to flow out of the cell, which resulted in a higher ion concentration and an increased conductivity. In addition, given that the conductivity increased with the rate of sterilization when the number of bacteria was ≥6.0 log, it may be possible to use the measure of conductivity as a means to rapidly estimate the number of bacteria that were sterilized by the pulsed high voltage. In order to determine the relationship between conductivities >0.01 μS/cm, which is the detection limit of the conductivity meter, and sterilization rate, regression analysis was performed, and the regression curve was derived as follows:
where X indicates sterilization rate and Y indicates conductivity.
Table 3 shows that there is a correlation between conductivity and sterilization rate (
p < 0.05). Since the intercept of the regression curve is negative, it may not be linearly proportional. In this experiment, it was difficult to measure conductivities <0.01 μs/cm due to the detection limit of the conductivity meter; however, by measuring lower conductivity, it is possible to derive the sterilization rate when the number of bacteria is <6.0 log.
Previous studies have only applied pulse voltages to VRE, without investigating the bactericidal effect of voltage waveform (pulse width), which is difficult to vary. While previous experiments mentioned the temperature of the bacterial solution, they did not control for temperature. The present experiments have clarified these conditions, and multiple regression analysis has highlighted the importance of temperature increase due to voltage application.
Furthermore, this sterilization method, which causes intracellular fluid to flow out, was found to allow for estimating the rate of sterilizations by changes in conductivity, a novel finding. Conventional impedance measurement methods using electrical means require collecting minute amounts of bacterial fluid (less than 1 mL) and detecting it using a high-frequency power supply, making them neither simple nor inexpensive [
29,
30,
31,
32]. However, measuring conductivity may allow for quickly and inexpensively estimating the number of viable bacteria, as demonstrated in this experiment. Although this method is limited to pulse application, the value obtained could be used to control the output voltage by providing feedback to the impulse power supply, enabling a highly energy-efficient sterilization method.
5. Conclusions
In this study, we tried to sterilize VRE using impulse voltage. We developed an impulse power supply and measured the sterilization rate by changing the voltage, pulse width, and temperature of the bacterial suspension. In addition, we measured the changes in electrical conductivity with the sterilization rate. The results are as follows:
Two types of impulse voltages with different buildup times were applied to VRE. The voltage waveforms and the current waveforms were almost identical, which indicated that bacterial suspension has a resistance load.
The rate of VRE sterilization differed depending on the value of the impulse voltage applied. When the application voltage was 7.5 kV or 4.5 kV, complete sterilization of the bacteria was observed at longer application times.
Impulse voltage was applied while controlling the temperature of the bacterial suspension. The higher the temperature of the bacterial suspension was, the higher the sterilization effect of the impulse voltage, and a sterilization rate of >9.0 log was achieved.
We confirmed the change in the conductivity of the bacterial suspension using impulse voltage. Our results suggested the presence of a correlation between the sterilization rate and conductivity.
This research clarified the sterilizing effect of the voltage waveform, specifically the pulse width, and the temperature of the bacterial solution on drug-resistant bacteria. In addition, in the context of this sterilization method, where intracellular fluid is shed, a new discovery is the potential to estimate the number of bacteria sterilized by tracking changes in conductivity. Although limited to pulsed disinfection methods, this change in conductivity may facilitate rapid and cost-effective identification of viable bacteria.
The ultimate goal of this study is to disinfect against drug-resistant bacteria in wastewater. Future research needs to confirm gene inactivation and bactericidal effects in bacterial solutions with high electrical conductivity.