Next Article in Journal
Parametric Study of Lightweight Wooden Wall Assemblies for Cold and Subarctic Climates Using External Insulation
Previous Article in Journal
Dynamic Properties of Soil Cements for Numerical Modelling of the Foundation’s Basis Transformed under the Technology of Deep Soil Mixing: A Determination Method
Previous Article in Special Issue
Ultrasonic Assessment of the Concrete Residual Strength after a Real Fire Exposure
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Editorial

Non-Destructive Testing for Building Evaluation

Faculty of Civil Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Buildings 2022, 12(7), 1030; https://doi.org/10.3390/buildings12071030
Submission received: 12 July 2022 / Accepted: 15 July 2022 / Published: 16 July 2022
(This article belongs to the Special Issue Non-destructive Testing for Building Evaluation)

1. Introduction

As of recent, non-destructive testing (NDT) has been used more frequently to evaluate and assess the condition of buildings. This evaluation includes a wide range of activities, including simple visual inspection; thermography; optical laser treatment; acoustic, radiological, and electromagnetic methods; and advanced tomography. At the construction stage, the materials and parts of the buildings are tested on site or in a laboratory. At the maintenance stage, buildings are more often monitored. Special efforts have been placed on the complementary application of various NDT techniques into an integrated structural health monitoring (SHM) system. More advanced techniques and algorithms are used to correlate the obtained signals and parameters from NDT measurements.
The main objective of this Special Issue is to share, present, and discuss recent applications of NDT for the evaluation and assessment of the condition of buildings. Particular focus was placed on real-world applications. The Special Issue starts with a compressive review of recent literature from the point of view of the evaluation of the adhesion between overlays and substrates in concrete floors, as well as non-destructive and semi-destructive testing methods used for this purpose [1]. This article also specifies some research gaps and possible future perspectives.
The rest of the Special Issue mainly contains articles that extend knowledge in the field of non-destructive testing for the evaluation of buildings with regards to the applications of ultrasonic, optical, thermographic, analytical, numerical, and laboratory methods.

2. Application of Ultrasonic Methods

Article [2] starts with interesting exemplary photos of cracks in a concrete cover after fire, as well as pictures of concrete surfaces after fires. Moreover, it discusses the color changes in concrete after fire. Samples for tests were taken after a fire from a 64 apartment building under construction. Core samples were tested across the sample’s height using the ultrasonic pulse velocity (UPV) method. The UPV method was validated with regards to the compressive strength of concrete, which was established based on the destructive strength tests. Afterwards, the distribution of the post-fire concrete strength across the sample’s height was evaluated using the UPV method. The presented method showed to be accurate as it can estimate the thickness of the concrete layer that is necessary to be removed or reinforced after being subjected to fire.
Another application of ultrasonic methods is presented in [3]. This time, the UPV method was used to evaluate the properties of cement-based materials modified with marble powder. The replacement ratios ranged from 5 to 15% of the amount of cement when compared to an unmodified reference sample. The UPV method showed to be a useful tool to indirectly evaluate the compressive strength and the apparent density of cement-based materials modified with marble powder. To support this statement, relationships between each of these parameters were also presented in the article.

3. Application of Optical Methods

Article [4] shows an application of close range photogrammetry (CRP) for the measurement of dynamic displacements of a three-dimensional one-story building frame model placed on a one-dimensional shake table. The performance of the CRP method was positively verified using a traditional method of attached accelerometers, as well as numerical models. The CRP method is also beneficial due to the fact that it measures displacements in three independent directions at the same time. Moreover, the cost and required time for instrumentation and analysis are relatively low when compared to other methods.
The dynamic analysis of elements made of simple monolithic glass is presented in [5]. This analysis was performed based on non-destructive laboratory tests, which were enhanced with operational modal analysis, numerical simulations, classical analytical models, and video-tracking techniques. In this research, the video-tracking technique showed a certain potential for dynamic investigations.

4. Application of Thermographic Methods

Article [6] proposes an experimental procedure which uses infrared thermography (IRT) to measure the surface temperature of building elements. Thanks to the proposed procedure, it is possible to approximate the thermal transmittance of the U-value. The application of IRT, in combination with the dynamic method (DYNM), could be successfully used for in situ tests. This is due to the fact that the DYNM does not need to have stable boundary conditions. Furthermore, the proposed procedure can also be used for a relatively fast and inexpensive approximation of the U-value without the use of expensive equipment that is needed in other methods (e.g., heat flux sensors).
Another interesting case study presents the application of thermographic methods in order to find structural elements and hidden openings in historic buildings in Osijek [7]. The first step of this research was to apply a steady-state thermographic method to analyze a building’s envelope. After that, evaluation was carried out using step heating.

5. Analytical, Numerical, and Laboratory Methods

Article [8] presents a new model for estimating the shear capacity of support zones that were reinforced longitudinally using fiber-reinforced polymer (FRP) bars instead of typical shear reinforcement. According to the authors, the shear strength, with regards to the proposed model, can be estimated using an accompanying (non-destructive) method for the empirical determination of the shear resistance of FRP bars.
The next valuable application of numerical methods is presented in [9]. This paper describes a case study of the dynamic characterization of a grandstand of a stadium in Lisbon. The grandstand was made of reinforced concrete. Data for the model, in the form of the natural frequencies and vibration modes, were taken from the performed ambient vibration tests on the analyzed grandstand. A sensitivity analysis provided evidence of the numerical fitting of the experimental results.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Szymanowski, J. Evaluation of the adhesion between overlays and substrates in concrete floors: Literature survey, recent non-destructive and semi-destructive testing methods, and research gaps. Buildings 2019, 9, 203. [Google Scholar] [CrossRef] [Green Version]
  2. Wróblewski, R.; Stawiski, B. Ultrasonic assessment of the concrete residual strength after a real fire exposure. Buildings 2020, 10, 154. [Google Scholar] [CrossRef]
  3. Toubal Seghir, N.; Benaimeche, O.; Krzywiński, K.; Sadowski, Ł. Ultrasonic evaluation of cement-based building materials modified using marble powder sourced from industrial wastes. Buildings 2020, 10, 38. [Google Scholar] [CrossRef] [Green Version]
  4. Ghaychi Afrouz, S.; Razavi, M.R.; Pourkand, A.; Mara Dias Wilson, C. Dynamic displacement of an aluminum frame using close range photogrammetry. Buildings 2019, 9, 176. [Google Scholar] [CrossRef] [Green Version]
  5. Bedon, C.; Fasan, M.; Amadio, C. Vibration analysis and dynamic characterization of structural glass elements with different restraints based on operational modal analysis. Buildings 2019, 9, 13. [Google Scholar] [CrossRef] [Green Version]
  6. Gaši, M.; Milovanović, B.; Gumbarević, S. Comparison of infrared thermography and heat flux method for dynamic thermal transmittance determination. Buildings 2019, 9, 132. [Google Scholar] [CrossRef] [Green Version]
  7. Glavaš, H.; Hadzima-Nyarko, M.; Haničar Buljan, I.; Barić, T. Locating hidden elements in walls of cultural heritage buildings by using infrared thermography. Buildings 2019, 9, 32. [Google Scholar] [CrossRef] [Green Version]
  8. Bywalski, C.; Drzazga, M.; Kamiński, M.; Kaźmierowski, M. A New Proposal for the Shear Strength Prediction of Beams Longitudinally Reinforced with Fiber-Reinforced Polymer Bars. Buildings 2020, 10, 86. [Google Scholar] [CrossRef]
  9. Santos, F.; Cismaşiu, C.; Cismaşiu, I.; Bedon, C. Dynamic characterisation and finite element updating of a RC stadium grandstand. Buildings 2018, 8, 141. [Google Scholar] [CrossRef] [Green Version]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Sadowski, Ł. Non-Destructive Testing for Building Evaluation. Buildings 2022, 12, 1030. https://doi.org/10.3390/buildings12071030

AMA Style

Sadowski Ł. Non-Destructive Testing for Building Evaluation. Buildings. 2022; 12(7):1030. https://doi.org/10.3390/buildings12071030

Chicago/Turabian Style

Sadowski, Łukasz. 2022. "Non-Destructive Testing for Building Evaluation" Buildings 12, no. 7: 1030. https://doi.org/10.3390/buildings12071030

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop