Next Article in Journal
Influence of Carbon Micro- and Nano-Fillers on the Viscoelastic Properties of Polyethylene Terephthalate
Next Article in Special Issue
Fabrication of a Double Core–Shell Particle-Based Magnetic Nanocomposite for Effective Adsorption-Controlled Release of Drugs
Previous Article in Journal
Hydrodynamic and Polyelectrolyte Properties of Actin Filaments: Theory and Experiments
Previous Article in Special Issue
3-O-Ethyl-L-Ascorbic Acid Doped Enteric-Coated Gelatin Capsules towards the Advanced Oral Curcumin Delivery for Cancers
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Effect of Common Mouthwashes on Mechanical Properties of Suture Materials Used in Dental Surgeries: A Laboratory Experiment

by
Shahabe Saquib Abullais
1,
Shaker Saleh AlOsman
2,
Sultan Mansoor AlQahtani
2,
Abdul Ahad Khan
3,*,
Rakhshinda Nahid
4,
Sulphi Abdul Basheer
3 and
Ahmad Saib Jameel
5
1
Department of Periodontics and Community Dental Sciences, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia
2
Inters, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia
3
Department of Oral and Maxillofacial Surgery, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia
4
Department of Periodontology, Faculty of Dental Sciences, Institute of Medical Sciences, Banaras Hindu University, Varanasi 221005, India
5
Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
*
Author to whom correspondence should be addressed.
Polymers 2022, 14(12), 2439; https://doi.org/10.3390/polym14122439
Submission received: 25 April 2022 / Revised: 25 May 2022 / Accepted: 2 June 2022 / Published: 16 June 2022
(This article belongs to the Special Issue Polymer Materials in Biomedical Application II)

Abstract

:
Background: Sutures play a pivotal role in promoting healing in any surgical procedure. However, the versatile nature of the oral environment entails additional properties in the suture materials to assure uneventful healing. A surgeon needs to understand these delicate intricacies in the immediate postoperative phase and needs some kind of algorithm in the selection of sutures that suits the different surgical scenarios. Therefore, a study was designed to observe the effect of four different types of mouthwash, viz. Avohex, Aloedent, Parodontax and Betadine, on the mechanical properties of Vicryl (polyglactin 910), PTFE (polytetrafluoroethylene), Prolene (polypropylene) and Mersilk. Methods: A total of 288 suture samples were divided in four equal groups (72 = each group) and used for the experiments. Tensile load, tensile strength as well as percentage elongation of the suture materials were evaluated in the various stated media at 3rd, 7th, 10th and 14th days, which were compared with the controls. The results were analyzed statistically and inferences were drawn. Results: Mersilk in (Avohex, Parodontax and Betadine) solutions showed a statistically significant decrease in tensile load over time. All the sutures had the highest tensile strength in Parodontax and had the lowest in Betadine solution. Vicryl and PTFE presented significant percentage elongation over time as compared to Prolene and Mersilk. Conclusion: The author has given certain recommendations but also states that there is no standard rule for the use of a particular suture material in all clinical situations. However, the selection of the suture material should be based on the type of surgery and preferences of the surgeon.

1. Introduction

Sutures are consistently being used for wound approximation in periodontal and oral surgical procedures for wound closure. In 3500 BC, the use of linen as suture material was first described by the Egyptians. Animal hair, vegetable fibers, silk, leather and gut have been successfully used as suture materials for wound closures [1]. Most sutures are made up of polymers. Polymers are large molecules made up of repeating units of small molecules called monomers. Sutures can be classified in several ways. Based on the raw material used, they can be either natural or synthetic. Depending upon their structure, they can be either monofilament or multifilament. Based on their resorptive and degenerative capacity, they can be categorized into absorbable and non-absorbable. Non-absorbable sutures resist their dissolution in saliva, oral fluids and serum. Moreover, a second appointment is required for their removal. Absorbable sutures are degraded by hydrolysis or by proteolytic enzymes, hence their removal is not essential [2,3].
Vicryl (Polyglactin 910) is a commonly used synthetic absorbable (resorbable) suture material obtained from a copolymer of 90% glycolide and 10% l-lactide. Polytetrafluoroethylene (PTFE) is a biologically inert, synthetic, non-absorbable (non-resorbable) suture material consisting of fluoropolymer of tetrafluoroethylene. Mersilk (silk) is a natural, non-absorbable suture material that is frequently used in oral and periodontal surgeries because of its superior handling characteristics [4,5]. Prolene (Polypropylene) is a synthetic, nonabsorbable suture material that is made from a polymer of propylene [5].
After the surgical procedure, the flaps are placed in close approximation with the help of sutures for an intended period of time; this is important to achieve healing through primary intention. Improper positioning of flaps results in healing by the secondary intention, which may compromise the results. The ideal suture material demands several specific characteristics, such as having adequate tensile strength, having the capacity to elongate with tissue edema, being biocompatible, being easy to manipulate while using, able to maintain a secure knot, and should biodegrade if used in internal wound closures [6,7]. Among the various intrinsic properties exhibited by a suture material, the tensile strength and percentage elongation are the most important in order to maintain the surgical flaps in position during the wound healing phase [8].
In oral surgery, suture induced wound healing is difficult as compared to the other parts of the body because of factors related to saliva, quality of the tissue involved, high level of vascularization and the dynamics of speech, mastication and swallowing [9,10]. In the oral cavity, significant variations in pH and temperature are inevitable due to the consumption of various types of foods and fluids. This variability is also caused by the use of prophylactic agents such as toothpastes and mouthwashes. Different suture materials exhibit dissimilar characteristics and soft tissue responses in the oral cavity [3,11,12].
A dental surgeon needs to understand the physical and mechanical properties of commonly used suture materials. At present, no suture fulfills all the requisites of an ideal suture material [13]. Most of the published data on the tensile behavior of sutures mainly focus on the tensile strength. Comprehensive reports on other vital properties of suture material such as percentage elongation, modulus and full stress-strain curves are quite limited in the field of periodontal and oral surgery.
In the present study, one absorbable and three non-absorbable suture materials were studied: Vicryl (polyglactin 910), PTFE (polytetrafluoroethylene), Prolene (polypropylene) and Mersilk (natural silk). The purpose of this study was to compare the effects of four different types of mouthwashes, namely Avohex, Aloedent, Parodontax and Betadine, on the mechanical properties of the above said suture materials, which are commonly used in periodontal, oral and maxillofacial surgeries.

2. Materials and Methods

The present in-vitro experimental study used four types of suture materials, out of which three were non-resorbable (silk, polypropylene and PTFE), whereas polyglactin 910 was resorbable (Table 1). All the suture materials used in the study were of uniform gauge (4-0). The type of suture material and their gauge were selected because of their frequent use in periodontal and oral surgery. The experimental design was presented to the institutional Ethical Review Board (King Khalid University, Abha, Saudi Arabia) to procure the ethical approval [SRC/ETH/2017-18/090]. The study was carried out between June 2021 and December 2021.
Four different types of thermostatically controlled test media, composed of mouthwashes, were used to evaluate the physical properties of these suture materials. The above setting was devised to simulate potential short-term intraoral exposure to various tested mouthwashes. The experimental media used were as follows:
Test group 1 (TT1) = Avohex; main ingredient: 0.2% chlorhexidine (Avalon Pharma, Sulimaniyah, Riyadh).
Test group 2 (TT2) = Betadine; main ingredient: 1% Povidone Iodine (Mundi Pharma, Alvarado, Argentina).
Test group 3 (TT3) = Aloedent; main ingredient: Aloe Vera (Optima naturals, Vergiate, Italy).
Test group 4 (TT4) = Parodontax; main ingredient: Aqua, glycerin, other (GlaxoSmithKline, Bradford, UK).
Artificial saliva was formulated by assimilating specific chemicals as mentioned in Table 2 in 1000 mL of distilled water [14]. Artificial saliva was preserved in an amber container until used for the experiment. During the experiment, the prepared artificial saliva was mixed with human serum (Human AB serum, Equitech-Bio, Kerrville, TX, USA) in the ratio of 1:1 concentration at 37 °C and a pH of 7.4 to 8.1 [6] to mimic the biologic simulation of the oral environment.
A total of 288 suture specimens were collected from sterile, unexpired and commercially available individual packs. All the suture specimens were cut to a uniform length of 14 cm. From each group, eight specimens were tested in the dry state for tensile strength (TS) before immersing it into the test media and were labeled as the control group. The rest of the 256 specimens were kept in artificial saliva until they were exposed to the test media. All the suture specimens were exposed to the test media for 2 min twice daily and returned to the artificial saliva after washing with normal saline. The comprehensive study protocol has been explained in Figure 1.
TS of the suture specimens was tested by the Universal Testing Machine (UTM) (Star Testing Systems, India. Model No. STS-248) which was connected to a computer for digital readout (Figure 2). TS of the suture specimens was assessed at specified time intervals: pre-immersion (dry), followed by post-immersion into test media on the 3rd, 7th, 10th and 14th day. Each suture specimen was secured by a modified jig between the opposite arms of the machine with a fixed distance of 10 cm. Pilot testing revealed that there was no slippage of jig or specimen failure by the above arrangement. TS assessment of each suture specimen was carried out at a cross-head speed of 5 mm/min. Each specimen was stretched until the material broke apart. The maximum load required to break the suture was documented in Newtons (N). The collected data was organized and subjected to statistical analysis.
The data on continuous variables were presented as mean and standard deviation across the 4 study groups. The intergroup statistical comparison of means of continuous variables was conducted using analysis of variance with Bonferroni correction for multiple group comparisons. The intragroup statistical comparisons were conducted by repeated measure analysis of variance in each study group. The underlying normality assumption was tested before subjecting each variable to the analysis of variance and repeated-measure analysis of variance. In the entire study, the p-value of less than 0.05 was considered to be statistically significant. All the hypotheses were formulated using 2-tailed alternatives against each null hypothesis (hypothesis of no difference). All data were statistically analyzed using Statistical Package for Social Sciences (SPSS version 22.0, IBM Corporation, New York, NY, USA) for MS Windows.

3. Results

At the end of the soaking period of suture materials in their respective media, all were intact and suitable for mechanical testing. Each suture material represented a unique apparent breaking point, firmness and elongation while being tested.

3.1. Tensile Load

All the values of tensile load for different suture materials in different test media are displayed in Table 3. From the table, it can be observed that the values of tensile load are maintained for all suture materials, in different solutions over a period except for Mersilk (in Avohex, Parodontax and Betadine solution) which shows a statistically significant decrease in tensile load over time.
Upon comparing the tensile load for different solutions within the group, it was noticed that PTFE and Mersilk both showed statistically significant differences on the 7th day, while for Prolene it was on the 14th day. All three specimens had the highest value for Parodontax and the lowest for Betadine. Vicryl shows a significant difference on the 10th and 14th day, having the highest load in Parodontax and the lowest in Betadine solution at both periods.

3.2. Tensile Strength

The mean values of TS for each suture material in different solutions at different periods are shown in Table 4. From the table, it can be observed that PTFE, Vicryl and Prolene maintained their TS at different periods, and the difference in TS over time is statistically nonsignificant. However, Mersilk shows a statistically significant decrease in TS from baseline until day 14th.
Upon intragroup comparison of TS in different solutions, it was observed that PTFE showed a statistically significant difference on day 7, Prolene on day 14 and Mersilk on day 7 and 14. All the above sutures had the highest strength in Parodontax and lowest in Betadine solution. Vicryl displayed a statistically significant difference at each period, having the highest value for Parodontax and the lowest for Betadine.

3.3. Percentage Elongation

Table 5 shows the values of percentage elongation of different suture specimens in different media over the stated period. From the table, it is found that different suture-material specimens showed a statistically significant difference in percentage elongation in different test media over the stated period. PTFE showed a statistically significant difference in percentage elongation over the period for Aloedent and Betadine solutions, but Vicryl shows a statistically significant difference in Betadine solution only. Meanwhile, Prolene and Mersilk show statistically significant differences in Aloedent and Parodontax solution at different time periods, respectively.
Upon intragroup comparison, PTFE showed a statistically significant difference in percentage elongation on the 7th and 10th day, whereas Vicryl showed a statistically significant difference on the 3rd, 7th and 10th day. However, Prolene and Mersilk showed significant differences on the 3rd and 7th day, respectively.

4. Discussion

A suture is a medical tool used to hold body tissues together after an injury or surgery. Most sutures are made of polymers. Polymers are made up of large number of individual repeating units called monomers. If individual repeating units are from one monomer, they are called homopolymers, whereas if they are made from a combination of two or more different monomers then they are called copolymers. The properties of a polymer depend on the structure of the monomer(s) used, the size of the polymer chain, and in the case of a copolymer, the composition and positioning of each repeating monomer chain [15]. The properties of the suture are determined by the molecular structure of the polymer and how the chains of polymers interact with each other. The structural characteristics of the polymer such as molecular mass, degree of entanglement, intermolecular forces and hydrogen bonding can affect the properties such as quality, drawability and strength when used to make a suture [15].
Clot formation and stabilization in the immediate postsurgical phase is an inevitable part of uneventful healing. Sutures play a pivotal role in achieving this objective. The biomechanical properties of the suture materials play a crucial role to neutralize the physiological tensile forces acting on the margins of the healing wound [16,17].
The purpose of this study was to compare the effects of four different mouthwashes, namely Avohex, Aloedent, Parodontax and Betadine, on the mechanical properties of silk, polypropylene, PTFE and Polyglactin suture materials. A single examiner carried out the entire study to minimize variability. The methodology used for this research was established according to previous studies [18,19]. Further, a 1:1 ratio of serum and saliva was used in our study to simulate possible oral surgical and periodontal surgical situations [6,20].
TS of suture material can be defined as the ratio of maximum (tensile) load that a suture can withstand without breaking, while being stretched to the original cross-sectional area of the given material [21]. It can be observed from the results that all suture materials maintained their tensile load in different solutions except Mersilk, in which the tensile load reduced over time. Similarly, it can be observed that PTFE, Vicryl and Prolene maintained their tensile strengths at different time periods, whereas Mersilk shows a statistically significant decrease in tensile strength from baseline until day 14. The reason could be that Mersilk is obtained from natural sources, so maybe more susceptible to the action of proteolytic enzymes from the bacteria as well as the host, whereas others are synthetic. Mersilk is not a polymer and is mainly composed of 70% protein fibers and 30% extraneous material or gum, whereas other suture materials are polymers. Furthermore, Mersilk is braided to increase the knot stability, which is very important during the wound-healing phase.
Previous studies have reported that absorbable materials have higher resistance to tension while nonabsorbable ones show lower resistance [22]. Khiste et al. inferred that polyglactin (Vicryl) sutures maintained their tensile strength until the 10th day but had minimal strength by the 14th day [23]. Another study by Ferguson et al. reported diminished tensile strength of Vicryl in saliva as compared to immersion in other liquids such as soy, saline or milk [24].
However, Chu et al. report that Vicryl shows better breaking strength as compared to natural sutures. This is especially evident after immersion in physiological and acidic pH solutions. They also reported that from among the nonabsorbable sutures, silk appears to be the most susceptible to various pH conditions [25]. Jose Arce et al. have stated in their research that Teflon (PTFE) and polyglactin (Vicryl) sutures maintained their strength after 21 days of evaluation [26]. On the other hand, the monofilament and Polyglactin (Vicryl) displayed higher tensile strength as compared to BS (black silk) and PTFE [27,28,29].
Chu et al. also reported that pH levels effected the performance outcome of absorbable sutures more than nonabsorbable ones. They further elaborated that both acidic and alkaline environments are able to accelerate the degradation of absorbable sutures [25]. Meanwhile, according to Ven Herdeen, only alkaline conditions accelerated the degradation of synthetic, or “man-made,” absorbable sutures [30].
Kearney CM et al., while evaluating the effect of various equine physiological and pathological fluids, on the rate of degradation of commonly used suture materials, found that multifilament suture materials demonstrate more rapid degradation as compared to monofilament sutures [31].
Percentage elongation or strain of a material describes the change in length of that material, as compared to its original length, before the breaking point is reached [31]. In our study, PTFE shows a statistically significant difference in percentage elongation over time for Aloedent and Betadine solutions, whereas Vicryl shows a difference in Betadine solution only. Meanwhile, Prolene and Mersilk show a difference in Aloedent solution and Parodontax solution, respectively.
Kearney CM et al. stated that incubation time significantly affected the percentage elongation for each suture type in all culture media. Further monofilament sutures displayed the highest yield to failure strain as compared to multifilament sutures, including polyglactin. It is also stated that monofilament suture (polydioxanone) exhibits a high level of elasticity in all media as compared to multifilament sutures (polyglactin) [31]. Naleway et al., while evaluating the mechanical properties of suture materials in general and cutaneous surgery, were of the opinion that increased elongation would be advantageous in situations where a great deal of edema is expected postoperatively [7].
We recommend that in spite of the statistically significant reduction in strength of Mersilk on 10th day, it retains approximately 90% of its strength until the 7th day, so can be recommended in surgical situations in which tissue immobilization of 5–7 days is sufficient to promote healing. At the same time, Parodontax should be prescribed alongside it as a mouthwash during the immediate postsurgical phase. However, if prolonged immobilization of 2 weeks is required, then PTFE should be preferred over Vicryl and Prolene. Aloedent or Parodontax should be prescribed as a mouthwash and Betadine should be avoided along with PTFE during the immediate postoperative phase. Further, Vicryl can be recommended if mild-to-moderate tissue edema is expected.
However, our study has a few limitations that restrict the application of the results in the clinical scenario. As it is an in vitro study, although we have tried to simulate the oral environment in/with regard to temperature and pH, we could not incorporate the microbiological component, which could affect our outcome significantly. Besides the effect of the diverse muscular actions related to the functional components of mastication, deglutition and speech could not be replicated in the experimental setup. Further, there is a scope for additional research as to explore the type of suture materials for use in the specific type of tissue.

5. Conclusions

Under the limitation of the present study, it can be concluded that various suture materials exhibit different properties under different circumstances, based on the degree of tissue edema expected, the amount of immobilization required, pH variations expected and the mouthwash recommended for oral hygiene maintenance. The recommendation of a particular suture material in all clinical situations, as a rule of thumb, cannot be justified. Therefore, the selection of the suture material should be tailored to the requirements of the surgery and preferences of the surgeon.

Author Contributions

Conceptualization, S.S.A. (Shahabe Saquib Abullais), S.M.A. and S.S.A. (Shaker Saleh AlOsman); methodology, S.S.A. (Shahabe Saquib Abullais), S.S.A.(Shaker Saleh AlOsman) and A.A.K.; software, R.N.; validation, S.S.A. (Shahabe Saquib Abullais), S.M.A. and S.S.A. (Shaker Saleh AlOsman); formal analysis, S.A.B., R.N. and S.S.A. (Shaker Saleh AlOsman); investigation, S.S.A. (Shahabe Saquib Abullais), S.M.A., A.A.K. and S.S.A. (Shaker Saleh AlOsman); data curation, S.S.A. (Shahabe Saquib Abullais), S.M.A. and S.S.A. (Shaker Saleh AlOsman); writing S.S.A. (Shahabe Saquib Abullais), R.N., S.A.B., A.S.J. and A.A.K.; writing—review and editing, A.A.K., S.S.A. (Shahabe Saquib Abullais), S.S.A. (Shaker Saleh AlOsman), S.M.A., S.A.B., A.S.J. and R.N.; supervision, S.S.A. (Shahabe Saquib Abullais); project administration, S.S.A. (Shahabe Saquib Abullais) and A.A.K.; funding acquisition, S.S.A. (Shahabe Saquib Abullais), and S.A.B. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

The data presented in this study are available on reasonable request from the corresponding author. The data are not publicly available due to privacy restrictions.

Acknowledgments

The authors extend their appreciation to the Deanship of Scientific Research at King Khalid University, Abha, KSA for funding this work through Large Research Group Project under grant number (RGP-2/234/1443).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Parell, G.J.; Becker, G.D. Comparison of absorbable with nonabsorbable sutures in closure of facial skin wounds. Arch. Facial Plast. Surg. 2003, 5, 488–490. [Google Scholar] [CrossRef] [PubMed]
  2. Jain, I.K.; Shetty, S.S. Effect of mouthwashes on the tensile strength of poliglecaprone and polyglactin absorbable sutures-An invitro study. IJDSIR 2020, 3, 224–230. [Google Scholar]
  3. Selvig, K.A.; Biagiotti, G.R.; Leknes, K.N.; Wikesjo, U.M. Oral tissue reactions to suture materials. Int. J. Periodontics Restor. Dent. 1998, 18, 474–487. [Google Scholar]
  4. Alshehri, M.A.; Baskaradoss, J.K.; Geevarghese, A.; Ramakrishnaiah, R.; Tatakis, D.N. Effects of myrrh on the strength of suture materials: An in vitro study. Dent. Mater. J. 2015, 34, 148–153. [Google Scholar] [CrossRef] [Green Version]
  5. Minozzi, F.; Bollero, P.; Unfer, V.; Dolci, A.; Galli, M. The sutures in dentistry. Eur. Rev. Med. Pharmacol. Sci. 2009, 13, 217–226. [Google Scholar]
  6. Vasanthan, A.; Satheesh, K.; Hoopes, W.; Lucaci, P.; Williams, K.; Rapley, J. Comparing suture strengths for clinical applications: A novel in vitro study. J. Periodontol. 2009, 80, 618–624. [Google Scholar] [CrossRef]
  7. Naleway, S.E.; Lear, W.; Kruzic, J.J.; Maughan, C. Mechanical properties of suture materials in general and cutaneous surgery. J. Biomed. Mater. Res. Part B 2015, 103, 735–742. [Google Scholar] [CrossRef]
  8. Von Fraunhofer, J.A.; Storey, R.S.; Stone, I.K.; Masterson, B.J. Tensile strength of suture materials. J. Biomed. Mater. Res. B Appl. Biomater. 1985, 19, 595–600. [Google Scholar] [CrossRef] [PubMed]
  9. La Scala, G.; Lleo, M.M. Sutures in dentistry. Traditional and PTFE materials. Dent. Cadmos 1990, 58, 54–58, 61. [Google Scholar]
  10. Gallini, G.; Pasqualini, M. Sutures in oral surgery. Attual. Dent. 1988, 4, 14–18. (In Italian) [Google Scholar]
  11. DeNardo, G.A.; Brown, N.O.; Trenka-Benthin, S.; Marretta, S.M. Comparison of seven different suture materials in the feline oral cavity. J. Am. Anim. Hosp. Assoc. 1996, 32, 164–172. [Google Scholar] [CrossRef]
  12. Banche, G.; Roana, J.; Mandras, N.; Amasio, M.; Gallesio, C.; Allizond, V.; Angeretti, A.; Tullio, V.; Cuffini, A.M. Microbial adherence on various intraoral suture materials in patients undergoing dental surgery. J. Oral. Maxillofac. Surg. 2007, 65, 1503–1507. [Google Scholar] [CrossRef]
  13. Holmlund, W. Physical properties of surgical suture materials: Stress-strain relationship. Stress-relaxation and irreversible elongation. Ann. Surg. 1976, 184, 189–193. [Google Scholar] [CrossRef] [PubMed]
  14. Gal, J.Y. About a synthetic saliva for in vitro studies. Talanta 2001, 53, 1103–1111. [Google Scholar] [CrossRef]
  15. Polymeric Medical Sutures: An Exploration of Polymer and Green Chemistry, Student Handout. Available online: https://csp.umn.edu/wp-content/uploads/2017/05/MedicalSutureExperiment-2.pdf (accessed on 25 January 2021).
  16. Wikesjö, U.M.E.; Nilveéus, R.E.; Selvig, K.A. Significance of Early Healing Events on Periodontal Repair: A Review. J. Periodontol. 1992, 63, 158–165. [Google Scholar] [CrossRef] [PubMed]
  17. Wikesj, U.M.E.; Nilveéus, R. Periodontal Repair in Dogs: Effect of Wound Stabilization on Healing. J. Periodontol. 1990, 61, 719–724. [Google Scholar] [CrossRef]
  18. Kim, J.C.; Lee, Y.K.; Lim, B.S.; Rhee, S.H.; Yang, H.C. Comparison of tensile and knot security properties of surgical sutures. J. Mater. Sci. Mater. Med. 2007, 18, 2363–2369. [Google Scholar] [CrossRef] [PubMed]
  19. Muffly, T.M.; Cook, C.; Distasio, J.; Bonham, A.J.; Blandon, R.E. Suture end length as a function of knot integrity. J. Surg. Educ. 2009, 66, 276–280. [Google Scholar] [CrossRef] [PubMed]
  20. Zoller, G.O.; Zentner, A. Initial attachment of human gingi- val fibroblast-like cells in vitro to titanium surfaces pre- treated with saliva and serum. Clin. Oral Implants Res. 1996, 7, 311–315. [Google Scholar] [CrossRef] [PubMed]
  21. Brandt, M.T.; Jenkins, W.S. Suturing Principles for the Dentoalveolar Surgeon. Dent. Clin. N. Am. 2012, 56, 281–303. [Google Scholar] [CrossRef]
  22. Abellán, D.; Nart, J.; Pascual, A.; Cohen, R.E.; Sanz-Moliner, J.D. Physical and Mechanical Evaluation of Five Suture Materials on Three Knot Configurations: An in Vitro Study. Polymers 2016, 8, 147. [Google Scholar] [CrossRef] [Green Version]
  23. Khiste, S.V.; Ranganath, V.; Nichani, A.S. Evaluation of tensile strength of surgical synthetic absorbable suture materials: An in vitro study. J. Periodontal Iplant Sci. 2013, 43, 130–135. [Google Scholar] [CrossRef] [Green Version]
  24. Ferguson, R.E., Jr.; Schuler, K.; Thornton, B.P.; Vasconez, H.C.; Rinker, B. The effect of saliva and oral intake on the tensile properties of sutures: An experimental study. Ann. Plast Surg. 2007, 58, 268–272. [Google Scholar] [CrossRef]
  25. Chu, C.C.; Moncrief, G. An in vitro evaluation of the stability of mechanical properties of surgical suture materials in various pH conditions. Ann. Surg. 1983, 198, 223–228. [Google Scholar] [CrossRef]
  26. Arce, J.; Palacios, A.; Alvítez-Temoche, D.; Mendoza-Azpur, G.; Romero-Tapia, P.; Mayta-Tovalino, F. Tensile Strength of Novel Nonabsorbable PTFE (Teflon®) versus Other Suture Materials: An In Vitro Study. Int. J. Dent. 2019, 2019, 7419708. [Google Scholar] [CrossRef] [Green Version]
  27. Craig, P.H.; Williams, J.A.; Davis, K.W.; Magoun, A.D.; Levy, A.J.; Bogdansky, S.; Jones, J.P., Jr. A biologic comparison of polyglactin 910 and polyglycolic acid synthetic absorbable sutures. Surg. Gynecol. Obstet. 1975, 141, 1–10. [Google Scholar]
  28. Katz, R.; Turner, R.J. Evaluation of tensile and absorption properties of polyglycolic acid sutures. Surg. Gynecol. Obstet. 1970, 131, 1–14. [Google Scholar]
  29. Pavan, A.; Bosio, M.; Longo, T. A comparative study of poly(glycolic acid) and catgut as suture materials. Histomorphology and mechanical properties. J. Biomed. Mater. Res. 1979, 13, 477–496. [Google Scholar] [CrossRef]
  30. van Heerden, J. Comparison of inflammatory response to polyglytone 6211 and polyglecaprone 25 in a rat model. S. Afr. Med. J. 2005, 95, 972–974. [Google Scholar]
  31. Kearney, C.M.; Buckley, C.T.; Jenner, F.; Moissonnier, P.; Brama, P.A. Elasticity and breaking strength of synthetic suture materials incubated in various equine physiological and pathological solutions. Equine Vet. J. 2014, 46, 494–498. [Google Scholar] [CrossRef]
Figure 1. Flow chart of the study.
Figure 1. Flow chart of the study.
Polymers 14 02439 g001
Figure 2. Suture specimen mounted by using modified attachments between the crossheads of universal testing machine.
Figure 2. Suture specimen mounted by using modified attachments between the crossheads of universal testing machine.
Polymers 14 02439 g002
Table 1. Details about the suture material used for the experiment.
Table 1. Details about the suture material used for the experiment.
Suture MaterialCompositionDegradationManufacturer
SilkNatural braided Non-absorbableMersilk, Ethicon,
J&J Pvt. Ltd., Mumbai, India.
Polyglactin 910Synthetic braidedAbsorbableVicryl, Ethicon,
J&J Pvt. Ltd., Mumbai, India.
PolypropyleneSynthetic monofilamentNon-absorbableProlene, Ethicon,
J&J Pvt. Ltd., Germany.
PolytetrafluoroethyleneSynthetic monofilamentNon-absorbableDental-A, Golnit Ltd., Kiev, Ukraine.
Table 2. Composition of artificial saliva.
Table 2. Composition of artificial saliva.
Chemical ConstituentsConcentration (mg/L)
Sodium chloride125.6
Potassium chloride963.9
Potassium thiocyanate189.2
Monopotassium phosphate654.4
Urea200.2
Sodium sulfate decahydrate763.2
Ammonium chloride178.0
Calcium chloride dihydrate227.8
Sodium bicarbonate630.8
Table 3. Tensile load (N) for each suture material in different solutions at different points (in time).
Table 3. Tensile load (N) for each suture material in different solutions at different points (in time).
MaterialsTensile Load (N) (Mean ± SD)ANOVA
Initial3 Days7 Days10 Days14 Daysp-Value
PTFEAVOHEX8.05 ± 0.67.69 ± 0.077.59 ± 0.077.25 ± 0.927.19 ± 0.490.482 NS
ALOEDENT8.05 ± 0.67.40 ± 0.067.25 ± 0.067.96 ± 0.087.20 ± 0.500.194 NS
PARODONTAX8.05 ± 0.69.70 ± 1.668.59 ± 1.666.70 ± 0.816.98 ± 1.240.105 NS
BETADINE8.05 ± 0.67.35 ± 0.137.00 ± 0.136.65 ± 0.646.85 ± 0.570.105 NS
ANOVAp-Value-0.124 NS0.008 **0.332 NS0.956 NS
VICRYLAVOHEX25.51 ± 6.923.38 ± 2.4022.83 ± 2.4022.00 ± 0.9218.77 ± 0.730.242NS
ALOEDENT25.51 ± 6.924.78 ± 1.3124.10 ± 1.3121.23 ± 0.9820.95 ± 0.320.359 NS
PARODONTAX25.51 ± 6.925.20 ± 1.0824.37 ± 1.0822.05 ± 0.7321.27 ± 1.150.426 NS
BETADINE25.51 ± 6.922.28 ± 1.7122.00 ± 1.7119.80 ± 0.5716.45 ± 1.330.064 NS
ANOVAp-Value-0.216 NS0.083 NS0.032 *0.001 ***
PROLENEAVOHEX15.05 ± 1.513.42 ± 0.7414.53 ± 0.7413.89 ± 0.6814.11 ± 0.550.353 NS
ALOEDENT15.05 ± 1.516.16 ± 0.3615.09 ± 0.3613.62 ± 1.3214.17 ± 1.360.177 NS
PARODONTAX15.05 ± 1.514.85 ± 0.8614.24 ± 0.8613.74 ± 0.5514.46 ± 0.750.596 NS
BETADINE15.05 ± 1.514.47 ± 2.2012.29 ± 2.2012.53 ± 0.7112.27 ± 0.450.074 NS
ANOVAp-Value-0.138 NS0.062 NS0.281 NS0.048 *
MERSILKAVOHEX13.81 ± 0.511.33 ± 0.9411.04 ± 0.9410.42 ± 0.8710.08 ± 0.46<0.001 ***
ALOEDENT13.81 ± 0.510.65 ± 2.2010.97 ± 2.2010.63 ± 0.5510.25 ± 0.650.018 *
PARODONTAX13.81 ± 0.512.38 ± 0.3012.44 ± 0.3011.34 ± 0.2510.66 ± 0.57<0.001 ***
BETADINE13.81 ± 0.510.38 ± 0.6010.08 ± 0.6010.10 ± 0.288.97 ± 0.28<0.001 ***
ANOVAp-Value-0.278 NS0.001 ***0.110 NS0.019 *
p-Value < 0.05 is considered to be statistically significant. * p-Value < 0.05, ** p-Value < 0.01, *** p-Value < 0.001, NS—Statistically nonsignificant.
Table 4. Tensile strength (MPa) for each suture material in different solutions at different points (in time).
Table 4. Tensile strength (MPa) for each suture material in different solutions at different points (in time).
MaterialsTensile Strength (MPa) (Mean ± SD)ANOVA
Initial3 Days7 Days10 Days14 Daysp-Value
PTFEAVOHEX434.27 ± 55.430.16 ± 3.15429.61 ± 3.15440.34 ± 12.05435.16 ± 11.760.997 NS
ALOEDENT434.27 ± 55.418.53 ± 3.92410.21 ± 3.92507.66 ± 2.80464.63 ± 29.920.141 NS
PARODONTAX434.27 ± 55.548.80 ± 94.08634.16 ± 94.08576.81 ± 85.81481.53 ± 30.140.077 NS
BETADINE434.27 ± 55.415.76 ± 7.84397.72 ± 7.84457.39 ± 20.09401.11 ± 3.340.423 NS
ANOVAp-Value-0.121 NS<0.001 ***0.115 NS0.075 NS
VICRYLAVOHEX1443.10 ± 3911315.70 ± 103.691246.70 ± 103.691204.13 ± 21.071213.23 ± 88.600.530 NS
ALOEDENT1443.10 ± 3911503.63 ± 36.881403.93 ± 36.881559.50 ± 136.311351.97 ± 44.050.722 NS
PARODONTAX1443.10 ± 3911651.90 ± 96.201448.63 ± 96.201532.27 ± 116.811355.60 ± 108.310.458 NS
BETADINE1443.10 ± 3911260.17 ± 223.941266.13 ± 223.941159.70 ± 68.59960.27 ± 58.020.150 NS
ANOVAp-Value-0.025 *0.040 *0.001 ***0.001 ***
PROLENEAVOHEX851.84 ± 86.64759.45 ± 41.85822.32 ± 41.85794.08 ± 75.98799.26 ± 31.190.490 NS
ALOEDENT851.84 ± 86.64914.66 ± 19.99853.69 ± 19.99784.77 ± 21.34801.94 ± 76.880.148 NS
PARODONTAX851.84 ± 86.64833.36 ± 36.91805.64 ± 36.91822.97 ± 38.26818.58 ± 42.340.895 NS
BETADINE851.84 ± 86.64818.58 ± 124.74725.60 ± 124.74816.51 ± 66.60699.45 ± 13.490.138 NS
ANOVAp-Value-0.127 NS0.121 NS0.808 NS0.05 *
MERSILKAVOHEX781.61 ± 29.34641.18 ± 52.68624.55 ± 52.68581.97 ± 62.62567.93 ± 51.490.001 ***
ALOEDENT781.61 ± 29.34602.38 ± 124.61620.95 ± 124.61639.34 ± 3.20580.21 ± 36.910.019 *
PARODONTAX781.61 ± 29.34700.32 ± 16.93704.01 ± 16.93642.52 ± 40.80602.97 ± 32.06<0.001 ***
BETADINE781.61 ± 29.34587.60 ± 33.72571.81 ± 33.72584.52 ± 76.01474.33 ± 39.02<0.001 ***
ANOVAp-Value-0.277 NS0.001 ***0.379 NS0.02 *
p-Value < 0.05 is considered to be statistically significant. * p-Value < 0.05, ** p-Value < 0.01, *** p-Value < 0.001, NS—Statistically nonsignificant.
Table 5. Percentage elongation for each suture material in different solutions at different points (in time).
Table 5. Percentage elongation for each suture material in different solutions at different points (in time).
MaterialsElongation (%) (Mean ± SD)ANOVA
Initial3 Days7 Days10 Days14 Daysp-Value
PTFEAVOHEX43.33 ± 6.727.37 ± 11.6733.31 ± 11.6726.23 ± 1.2432.37 ± 8.490.176 NS
ALOEDENT43.33 ± 6.729.94 ± 2.2149.44 ± 2.2113.50 ± 2.9734.13 ± 2.300.009 **
PARODONTAX43.33 ± 6.727.37 ± 18.3818.28 ± 18.3817.60 ± 1.2731.95 ± 1.840.068 NS
BETADINE43.33 ± 6.721.81 ± 2.3920.55 ± 2.3922.90 ± 0.4225.24 ± 2.640.004 **
ANOVAp-Value-0.896 NS0.025 *0.007 **0.367 NS
VICRYLAVOHEX21.54 ± 8.921.21 ± 5.6922.25 ± 5.6920.91 ± 1.8220.95 ± 4.640.998 NS
ALOEDENT21.54 ± 8.929.78 ± 0.7025.96 ± 0.7023.96 ± 3.3424.79 ± 3.990.351 NS
PARODONTAX21.54 ± 8.931.00 ± 2.3424.87 ± 2.3425.20 ± 0.6423.79 ± 1.920.174 NS
BETADINE21.54 ± 8.923.96 ± 5.2138.62 ± 5.2128.54 ± 2.6024.89 ± 2.000.014 *
ANOVAp-Value-0.05 *0.000 ***0.024 *0.482 NS
PROLENEAVOHEX32.16 ± 5.630.04 ± 1.7534.75 ± 1.7535.25 ± 6.2828.34 ± 0.390.298 NS
ALOEDENT32.16 ± 5.644.54 ± 3.6933.58 ± 3.6931.96 ± 2.1329.62 ± 4.750.011 *
PARODONTAX32.16 ± 5.628.04 ± 3.0636.08 ± 3.0632.37 ± 4.3631.83 ± 2.780.689 NS
BETADINE32.16 ± 5.633.46 ± 7.7833.30 ± 7.7841.37 ± 6.3029.22 ± 0.960.195 NS
ANOVAp-Value-0.01 **0.963 NS0.165 NS0.507 NS
MERSILKAVFAOHEX15.21 ± 2.217.96 ± 2.1917.83 ± 2.1913.62 ± 2.6815.00 ± 1.390.104 NS
ALOEDENT15.21 ± 2.215.58 ± 3.7217.79 ± 3.7216.46 ± 0.7412.58 ± 1.920.131 NS
PARODONTAX15.21 ± 2.221.83 ± 5.1421.08 ± 5.1416.41 ± 1.3012.82 ± 1.660.009 **
BETADINE15.21 ± 2.214.91 ± 2.3916.86 ± 2.3915.66 ± 0.9115.60 ± 2.140.759 NS
ANOVAp-Value-0.153 NS0.009 **0.182 NS0.172 NS
p-Value < 0.05 is considered to be statistically significant. * p-Value < 0.05, ** p-Value < 0.01, *** p-Value < 0.001, NS—Statistically nonsignificant.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Abullais, S.S.; AlOsman, S.S.; AlQahtani, S.M.; Khan, A.A.; Nahid, R.; Basheer, S.A.; Jameel, A.S. Effect of Common Mouthwashes on Mechanical Properties of Suture Materials Used in Dental Surgeries: A Laboratory Experiment. Polymers 2022, 14, 2439. https://doi.org/10.3390/polym14122439

AMA Style

Abullais SS, AlOsman SS, AlQahtani SM, Khan AA, Nahid R, Basheer SA, Jameel AS. Effect of Common Mouthwashes on Mechanical Properties of Suture Materials Used in Dental Surgeries: A Laboratory Experiment. Polymers. 2022; 14(12):2439. https://doi.org/10.3390/polym14122439

Chicago/Turabian Style

Abullais, Shahabe Saquib, Shaker Saleh AlOsman, Sultan Mansoor AlQahtani, Abdul Ahad Khan, Rakhshinda Nahid, Sulphi Abdul Basheer, and Ahmad Saib Jameel. 2022. "Effect of Common Mouthwashes on Mechanical Properties of Suture Materials Used in Dental Surgeries: A Laboratory Experiment" Polymers 14, no. 12: 2439. https://doi.org/10.3390/polym14122439

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop