Review

Wind Load and Wind-Induced Vibration of Photovoltaic Supports: A Review

by
Bo Nan
1,
Yuanpeng Chi
1,
Yingchun Jiang
2,* and
Yikui Bai
1
1
College of Water Conservancy, Shenyang Agricultural University, Shenyang 110866, China
2
College of Engineering, Shenyang Agricultural University, Shenyang 110866, China
*
Author to whom correspondence should be addressed.
Sustainability 2024, 16(6), 2551; https://doi.org/10.3390/su16062551
Submission received: 19 January 2024 / Revised: 22 February 2024 / Accepted: 5 March 2024 / Published: 20 March 2024
(This article belongs to the Special Issue Energy Technology and Sustainable Energy Systems)

Abstract

:
(1) Background: As environmental issues gain more attention, switching from conventional energy has become a recurring theme. This has led to the widespread development of photovoltaic (PV) power generation systems. PV supports, which support PV power generation systems, are extremely vulnerable to wind loads. For sustainable development, corresponding wind load research should be carried out on PV supports. (2) Methods: First, the effects of several variables, including the body-type coefficient, wind direction angle, and panel inclination angle, on the wind loads of PV supports are discussed. Secondly, the wind-induced vibration of PV supports is studied. Finally, the calculation method of the wind load on PV supports is summarized. (3) Conclusions: According to the particularity of the PV support structure, the impact of different factors on the PV support’s wind load should be comprehensively considered, and a more accurate method should be adopted to evaluate and calculate the wind load to lessen the damage that a PV support’s wind-induced vibration causes, improve the force safety of PV supports, and thereby enhance the power generation efficiency of PV systems.

1. Introduction

Environmental problems have become increasingly severe in recent years. Given the goals of “peak carbon dioxide emissions”, “carbon neutrality”, and compliance with the requirements of sustainable development, PV power generation is a promising renewable energy generation method because of both its environmental protection and economy, and it has been widely developed [1]. China generated 241.4 billion kWh of PV power in 2021 and 325.9 billion kWh in 2022, indicating an annual increase of 35%. However, wind damage to PV supports occurs from time to time, and the most significant load when designing PV supports is the wind load. Therefore, wind resistance is essential for a safe, durable, and sustainable PV power generation system.
There are three modes of support in PV power generation systems: fixed [2], flexible [3], and floating [4,5]. Fixed PV supports are structures with the same rear position and angle. They have the advantages of mature technology, wide application, and simple overhaul and maintenance. In contrast, they face the disadvantage of limited application scope. Meanwhile, a flexible PV panel support is installed on rows of steel cables, which are connected by rigid supports at two ends, realizing a structure spanning 10–30 meters [6]. In addition, external tensile stay cables or internal rigid diagonal supports are used at both ends of the support to reduce the bending moment of the top support at the ends [7,8]. As such, it has the advantages of an extensive and flexible span range, a significant utilization rate of land space, flexible operation, good ventilation performance, and high power generation efficiency [9]. To a certain extent, it can be mutually beneficial regarding crops. A problem, however, is the immaturity of the technology. A floating PV support is a structure that uses PV panels that are fixed by anchor blocks and floats on the water’s surface with a buoy. It not only does not require the construction of a foundation but also adapts to the fluctuations of the water level and helps to achieve the goals of “complementary fishing and light” in water power generation and underwater fish farming [10]. It does not occupy land resources; at the same time, the use of water to cool the PV array can improve the output power and reduce the cost of additional cooling devices for air and water cooling [11,12]. However, floating PV supports at sea level are vulnerable to seawater erosion, and there are few studies on floating PV supports. The specific advantages and disadvantages of the three are shown in Figure 1.
Wind often damages PV supports. The wind load is the most significant load considered while designing a PV support [13]. Therefore, wind resistance is essential for a safe and durable PV power generation system. The impact of the wind load on a floating PV support is smaller than that on other PV supports, but regardless of whether fixed or flexible supports are used, the wind load is considered first. Making full use of the previous research results, the following are the main wind load issues associated with the three types of PV supports: (1) the factors affecting the wind loads of PV supports—the main factors are shown in Figure 2; (2) the wind-induced vibration of PV supports; (3) the value and calculation of the wind load of a PV support. It is hoped that this review will provide a reference for the improvement of the wind resistance of PV supports.

2. Influencing Factors of Wind Load of PV Panel Support

2.1. Panel Inclination Angle

The angle β between the PV panel and the horizontal plane is called the panel inclination (Figure 3). Because of the PV panel’s varying inclination angle, a PV power generation system’s wind load varies, impacting the system’s power generation efficiency.
Ma [14,15] et al. investigated the impact of the inclination parameters on the wind load of a PV panel support in a pressure-measuring wind tunnel using rigid PV panel models. The wind load of the PV support was found to be sensitive to the panel inclination angle; in other words, the size coefficient of the PV panel and wind load increased as the inclination angle increased. However, it is not true that the lower the panel inclination angle, the better; when considering the power generation efficiency, the panel inclination angle will have a critical point, but the critical point value remains to be studied. Li [16,17] et al. investigated the influence law of the dip angle and other parameters on the PV wind load on the roof by conducting wind tunnel tests with a rigid scaling model on a single- and double-slope PV vehicle shed (Figure 4 and Figure 5) with a roof dip angle of 20° and 30°. The following conclusions were drawn from their work: (1) the more significant the slope inclination, the greater the wind load value; (2) the windward corner and the leeward ridge sections displayed the highest and lowest wind pressure coefficients of the most disadvantageous measuring location. The greater the slope inclination, the greater the extreme wind suction of the measuring point. The wind distribution of pressure on the surfaces of independent roof panels of flat buildings with modest geometric proportions was investigated by Stathopoulos [18] et al. The test results showed that the panel inclination with the critical wind direction angle of 135°, at which the panels on the back experienced higher suction compared to those in the front, had an impact on the net values of the pressure coefficients corresponding to different configurations.
A large-scale PV system model installed on a residential structure was tested in a wind-wall research facility by Naeiji [19] et al., who concluded that the gap height and building height had little influence on the roof PV support structure, and the wind load value changed by only 5%. The most critical factor influencing the peak pressure coefficients that were produced was the panel inclination angle, and the wind load value changed by 43%. The greater the panel inclination angle, the greater the wind load of the roof PV support structure. Qiao [20] et al. employed computational fluid dynamics (CFD) to examine the PV support array’s wind field and suggested regional division methods for varying dip angles and wind load shape coefficients. Kopp [21] et al. performed a wind tunnel study on roof-mounted solar arrays with two panel inclination angles. Two main mechanisms for the aerodynamic loads were obtained: (1) the panels’ turbulence; (2) pressure equalization. The array created turbulence at high inclination angles, which raised the net wind loads. Meanwhile, pressure equalization predominated for small inclination degrees.
At Florida International University’s Wall of Wind Facility, Naeiji [22] et al. conducted extensive experimental wind testing to examine the effects of geometric parameters on PV systems. The panel inclination angle was the most significant factor influencing wind-induced pressures. The crucial spots with the highest wind pressures were then identified. Jiang [23] et al. examined how the PV array’s installation angle and other elements affected the wind load. The body shape and bending moment coefficients of each PV panel rose with the wind direction angle of 30° or 180° when the PV array was installed at a 45° angle. Consequently, the PV array installation angle should not be 45°. Yemenici [24] et al. investigated how the inclination angle affected ground solar panel flow structures, finding that the wind directions and panel inclination angles had a significant impact. The impact of various panel inclination angles on the wind loads of PV supports is summarized in Table 1.
The investigations stated above established that the inclination angle significantly impacted the wind loads of PV supports. It was discovered that the wind load was the most crucial factor when designing PV supports. Future research should concentrate on the sensible arrangement of the PV panel’s inclination angles and the improved wind resistance of the PV support system’s design. This gives a theoretical foundation for the wind-resistant design of PV panel supports.

2.2. Wind Direction Angle

The wind direction angle, represented by α and having a value range of 0° to 180°, is the angle formed between the wind direction and the PV panel’s long-axis direction on the horizontal plane (Figure 6). The wind direction angle significantly influences the wind load on PV supports. For example, distinct wind loads are produced on PV supports at varying wind direction angles. For flexible PV supports, the wind load is highly sensitive when the wind direction angle is 150°. In contrast, the wind load affects fixed PV panel supports and arrays differently.
Du [25] et al. used the ANSYS 2022R2 finite element software to study the structural wind pressure of a flexible PV support with an increase in the wind azimuth, which refers to the position where the highest absolute value of the wind pressure coefficient gradually moves. Meanwhile, several scholars have analyzed the relationship between the wind angle and fixed PV supports. Using CFD, Huang [26] et al. separately compared the wind load at different azimuthal angles in fixed PV panels and trackers. They discovered that, because of the tracker panels’ massive left–right clearance and modest length-to-height ratios at 45° and 135° wind diversion angles, their wind loads were more significant than those of the fixed panels. Li [27] et al. conducted a numerical wind tunnel simulation for the Hami Chengzi PV system. At wind angles of 90° and 180°, the variation laws of the wind load were similar along the downwind direction; in other words, the windward area had an overall positive pressure, whereas the downwind area had an overall negative pressure. The first two rows of the windward zone had significant variations in the body type coefficient. A rigid model (Figure 7) with a tilt-adjustable PV panel was tested in a wind tunnel by Yin [28] et al. to determine the wind loads on the structure at various wind inclinations and directions. The most sizeable local wind pressure was produced at the windward angle with 45° and 135° wind direction angles, according to the results.
Regarding PV arrays, Xu [29] et al. used CFD numerical modeling to assess the wind loads on PV panels at various angles and locations. The wind load variation law was then determined at wind direction angles of 0° and 180°. A thorough study of the wind loads on the array of the surrounding wind field was conducted by Jubayer [30] et al. The third row had the lowest wind loads for wind direction angles of 0° and 180. Shademan [31,32] et al. used three-dimensional Reynolds-averaged Navier–Stokes and CFD simulations to examine the impact of the wind direction angle on PV arrays. The initial findings provided a theoretical foundation for the following wind-resistant design since they demonstrated that the wind load of the structure reached its most significant value at wind direction angles of 0° and 180°. Table 2 summarizes the impact of the wind direction angle on the wind loads of PV panel supports.
The works mentioned above determined that different wind angles cause the position of the maximum wind load to vary, resulting in different positions for possible damage. Therefore, the design at the position of the maximum wind load should be strengthened to increase the wind resistance, safety, and reliability of PV panel supports.

2.3. Body Type Coefficient

The definition of the body type coefficient is as follows:
C p i = P i P s P t P s = P i P s 0.5 ρ U r 2
C p i : the average wind pressure coefficient of measuring point i at different wind angles;
P t : the total pressure at the height of the reference point;
P s : the static pressure at the reference point height;
P i : the pressure at point i at different wind direction angles;
U r : the average wind speed at the height of the reference point.
μ s i = C p i 10 Z i 2 ϕ
μ s i : the body type coefficient at measuring point i ;
Z i : the height at point i ;
ϕ : the ground roughness index.
The body type coefficient is a significant component influencing the wind load of a PV support. In general, the larger the size factor, the greater the wind load of the PV support. Huang [33] et al. used Fluent to numerically calculate and analyze the surface wind pressure distribution characteristics of PV panel arrays and proposed the body type coefficient for a PV panel group with a wind-resistant design. After researching a single row of PV supports in a wind tunnel, Niu [34] et al. discovered the distribution law of the body type coefficient when the front and rear PV panels interfered. Wang [35] et al. analyzed the wind load distribution of PV panels on a flat roof array by using the wind tunnel test method and concluded that the closer the overall body type coefficient of the PV panels is to the edge of the roof, the greater the wind load that they will bear.
At the same time, some factors will also affect the body type coefficient of the wind load of a PV support and the size of the wind load. Huang [36] et al. studied the wind load distribution on solar PV panels using the wind tunnel test of a rigid model. The experimental results showed that, because of the existence of upstream PV panels, the shape coefficients of the downstream PV panels will decrease to a certain degree. Through a numerical wind tunnel, Huang [37] et al. simulated the body type coefficient of a simplified solar tracker PV panel model. Their research demonstrated that the body type coefficient increased with the gradual increase in the PV panel’s elevation angle under each wind direction. In contrast, Wang [38] et al. conducted a wind tunnel test with simultaneous pressure measurement in a uniform turbulent field and used Fluent to numerically simulate and calculate the body type coefficient distribution of the group support under a specific wind direction. The computational findings demonstrated that the test data were compatible with the numerical calculation results and the change rules were consistent when compared to the corresponding results of the wind tunnel test. This gives theoretical justification for the design of wind-resistant PV supports.
The study mentioned above established the significant impact of the body type coefficient on the PV supports’ wind load. Therefore, the body type coefficient should be controlled reasonably to increase the wind resistance of the PV panel support system.

2.4. Geometric Scale

The geometric scale is a significant issue influencing the wind loads of PV supports. In particular, the wind loads of PV supports with different geometric scales differ. Aly [39,40,41] et al. investigated the causes of the variations in peak wind load using a CFD simulation. The findings demonstrated that the geometric size was the primary cause of the various peak wind loads. Using scale models in a boundary-layer wind tunnel, Kopp [42] et al. investigated the wind loads on low-profile roof-mounted solar arrays. The pressure coefficient showed a linear increase with an increasing inclination angle for tilt degrees less than 10°. To investigate the impact of the geometric scale on the wind-induced pressure of rooftop solar panels, Alrawashdeh [43] et al. created, produced, and tested three models in the atmospheric-boundary-layer wind tunnel of Concordia University (Figure 8) with geometric ratios of 1:50, 1:100, and 1:200, respectively. The findings demonstrated the significance of the geometric test scale for solar panel models, particularly when considering the design wind load.
The works mentioned above establish the importance of the geometric scale in the PV panel supports’ wind load. In particular, different geometric scales result in differences in the peak wind load of the PV panel support. In future works, the geometric scale of PV panels should be reasonably designed to strengthen their wind resistance.

2.5. Shielding Effect

The shielding effect results in different wind loads at different locations of PV supports. For a numerical simulation and analysis, Fang [44] et al. used ANSYS 19.0 software on PV arrays with a wind angle ranging from 0° to 180°. The simulation result showed that the PV array barrier between the plates impacted the wind load, which led to varying wind loads on the PV panels at various locations. Bitsuamlak [45] et al. examined four test situations to ascertain the impact of wind on independent ground-mounted solar panels. The investigation showed that the wind loads on the neighboring solar panels organized in tandem were significantly decreased by the prominent shielding effect generated by the upwind solar panels. Radu [46] et al. investigated the steady-state wind load characteristics affecting two rectangular flat panel solar collectors of varying sizes through experiments in boundary-layer wind tunnels. Because of the building’s and the first row of collectors’ sheltering qualities, the wind loads on the solar collectors significantly decreased. The variations in the PV body type coefficients with the inclination angle and panel number were investigated by Lou [47] et al. Upstream PV panels were found to exhibit a notable shielding effect on downstream PV panels, which remained stable with the number of upstream PV panels.
The shielding effect is inevitable for PV panel arrays. The investigations above demonstrate how the shielding effect affects the wind stress on PV panel supports. To serve as a guide for the design of PV panel supports with wind resistance, future research should reduce the impact of the shielding effect on the wind loads of the supports.

2.6. Template Gap

One crucial aspect influencing the wind load of a PV support is the template gap. However, different academics have differing views regarding the influence of the template gap on the wind loads of PV supports; some believe the impact to be quite significant, while others do not.
In a numerical simulation investigation of PV arrays, Ruan [48] et al. concluded that the installation gap of the panels can alter the distribution of wind stress on the upper and lower surfaces of the panels overall. The pressure field on the upper and bottom surfaces of PV panels was investigated by Abiola-Ogedengbe [49] et al. in a wind tunnel. The findings indicated that the template gap would affect the components’ surface pressure field. Stenabaugh [50] et al. studied the influence of geometric shapes on the wind loads acting on PV arrays and found that the more significant the gap between panels, the smaller the gap between the panels and roof surfaces and the smaller the net wind loads generated. Yemenici [51] et al. found that the panel gap had a more significant influence on the wind loads of intermediate panels after conducting aerodynamic load measurements on ground-based solar panel arrays. Shademan [52] et al. examined the effects of ground clearance on the average wind load and fluctuating wind loads of solar panels by utilizing the detached eddy simulation method, and the results showed that an increase in clearance would cause an increased average wind load and unstable wind load. Warsido [53] et al. investigated the effects of various spacing parameters on the wind loads of the ground and roof solar arrays in a boundary-layer wind tunnel. They discovered that the wind load coefficient rose as the panel line spacing increased, while the wind load of the roof array decreased as the building edge perimeter spacing increased. Cao [54] et al. carried out several wind tunnel tests to assess the wind stresses on flat roof PV panels. The results showed that the distance between the arrays increased the opposing panel force.
However, according to Wood [55] et al.’s wind tunnel tests, adjusting the panel spacing had a minimal impact on the pressure recorded for solar panel arrays. Geurts [56] et al. conducted wind tunnel experiments (Figure 9) to ascertain the net uplift stress on these systems. In the wind tunnel, they studied the impact of the space between the panel and the roof. According to the results, the effects of the space between the PV system and the roof surface were minor. He [57] et al. conducted numerical simulation calculations on the wind loads of PV panels and drew the following conclusion: in a panel array, the panel gap has little influence on the wind load.
Although a few scholars posit that the template gap has little influence on the wind loads of PV support structures, most scholars still believe that the smaller the template gap and the larger the ground clearance, the greater the wind load generated. Therefore, the influence of the template gap cannot be ignored, and the specific impact of the template gap on the wind load of the PV support structure needs to be further tested and studied. It is also necessary to reasonably increase the template gap and reduce the ground clearance in order to reduce the wind load of the PV support structure, enhance the wind resistance of the PV support structure, and improve the safety and reliability of the PV support structure.

2.7. Other Factors

It is not only the panel inclination angle, wind direction angle, body type coefficient, geometric scale, shielding effect, and template gap that affect the wind load of the PV support; some other parameters also affect it. Erwin [58] et al. conducted wind tunnel tests on rooftop PV panels to develop a data set of aerodynamic loading effects for rooftop PV systems. The results showed that reasonable agreement was obtained between the WoW and wind tunnel results regarding the lateral and uplift load coefficients for the most critical panel inclination angle of -45° for the flat roof and the 5:12 gable roof. Based on an experimental study, Pfahl [59] et al. concluded that the wind load components varied partly with the panel’s aspect ratio. As a result, when organizing the parts of solar trackers, the aspect ratio needs to be considered. Consequently, the effect of the building side was investigated by Wang [60] et al., who conducted wind tunnel studies to study the effects of a constant building height. The results demonstrated a growing trend in the net pressure coefficients for the most significant negative peak area across all wind directions and panels when the inside ratio increased. Ma [61] et al. utilized inflexible models to conduct pressure wind tunnel experiments to investigate the impact of the bottom-flow obstruction ratio on the wind load on the surface of the PV panels. The findings indicated that a bottom-flow blockage significantly enhanced the maximum wind suction on the PV panel, hence decreasing the maximum wind pressure and wind-induced bending moment on the PV panel. Chai [62] et al. conducted several wind tunnel tests (Figure 10) and assessed a stiff panel’s pressure to determine the wind pressure coefficients on the PV panel. A wind load model that considered the wind-induced moment was presented based on the nonuniform distribution of wind pressure. This proposed model and its distribution coefficients can be used in designing flexibly supported PV panels.
In order to methodically examine the wind loads on solar panels installed on tall building rooftops, Dai [63] et al. carried out several pressure tests. They concluded that lower-height structures typically produce more pronounced variations in the wind pressure on solar panels. Zhang [64] et al. analyzed the wind load characteristics of near-ground PV arrays shielded by walls, whereby the wall height was found to have a notable impact on the wind load. Browne [65] et al. investigated the impact of parapets on the wind loading of a rooftop solar array with a 10° inclination angle using a scale model wind tunnel test. For many arrays, the parapet effect raised the peak wind load at standard parapet heights. Banks [66] et al. investigated the uplift wind loads on the roofs of wide, rectangular, low-rise, flat-roofed buildings using tilted flat PV panels in an atmospheric boundary-layer wind tunnel. The findings showed a significant difference in wind load between the corner vortices and the cases without them. Pratt [67] et al. conducted a study on the wind patterns surrounding solar arrays that were installed on roofs. Significant vertical gusts caused southern wind peak uplifts at larger inclination degrees, while northern wind peaks were attributed to gusts in the streamwise direction. Wang [68] et al. examined the specific features of wind loads on solar arrays installed on flat roofs with deflectors, as well as those on gable roofs. When comparing gable roofs to flat roofs, the study found that the solar arrays on flat roofs saw more extensive and more rapidly decreasing negative peak net pressures, particularly as the tributary area increased. Aly [69] et al. systematically investigated the wind loads on solar panels installed on various roof zones. This was done in a boundary-layer wind tunnel, considering varied wind directions (Figure 11). The cladding loads on the individual panels either exceeded or fell short of those on the same area of an uncovered roof. To prevent excessive net minimum pressures from affecting the PV panels, it is advisable to steer clear of the sensitive zones of the roof.
When designing PV support systems, the wind load is the primary load to consider for PV power generation. The amount of the PV wind load is influenced by various elements, such as the panel inclination angle, wind direction angle, body type coefficient, geometric scale, shielding effect, and template gap. Therefore, in future works, the reasonable control of the influence of each factor on the PV wind load is necessary to strengthen the wind-resistant design of PV power generation systems.

3. Wind-Induced Vibration of the PV Support

3.1. Wind-Induced Vibration

For PV panels, due to the absorption of solar energy, the temperature may be too high; this is only one of the reasons for the increase in the temperature of PV panels [70], which also reduces the power generation efficiency of PV panels. A wind load accelerates the cooling of PV panels, thereby reducing the cell’s temperature and increasing the power generation efficiency for PV power generation. However, the PV panel generates wind-induced vibration due to the wind load, which can damage the system (Figure 12). To solve this problem, a new method has been used to analyze the reliability of solar PV systems.
Ma [71] et al. conducted a wind tunnel test to assess the vibration of elastic models and explored how different parameters affected the wind-induced vibration of tracking solar PV panels. He [72] et al. conducted multiple wind tunnel experiments to examine the vibration properties of PV panels supported by suspension cables. The primary findings can be summarized as follows: cable-supported PV panels are susceptible to significant vibrations when exposed to crosswinds; leeward PV panels experience less vibration than windward panels, primarily due to the shielding effect. Using CFD simulations, Jubayer [73] et al. looked into the wind loads surrounding a series of solar panels on the ground. A thorough examination of the impact of wind on a solar panel array installed on the ground was achieved by considering both direct and oblique wind directions. In order to investigate the changes in the wind-induced vibration of PV panels, considering the wind speed, Li [74] et al. tested elastic-suspension segmental models with varying PV panel inclinations in wind tunnels. The flexible PV segmental models’ flutter critical wind speed values at different inclinations were also found. Wang [75] et al. used an arrangement involving two diagonal tie bars and one vertical rigid bar to analyze the modal and maximum displacement curve under wind–pressure time history excitation and investigated the control effect of different vibration control methods on multirow flexible supports. The results showed that the vertical rigid rod arrangement could effectively coordinate the displacement of the upper chord, middle–upper chord, middle–lower chord, and lower chord at different survey points across the middle and simultaneously reduce the inconsistencies concerning the displacement of the strings of multiple rows of flexible PV supports. Zhao [76] et al. analyzed the displacement state of a structure using two analysis methods with and without consideration of the spatial correlation of the pulsating wind, in order to investigate the suspension cables of a long-span support system accurately. The displacement states of the upper and lower chords of the structure were investigated. For structures exhibiting a large span and long space, the spatial correlation of the pulsating wind may not be considered, adversely affecting the analysis results. Consequently, an envelope design for a large-span stent system was recommended. A response history analysis was employed by Schellenberg [77] et al. to examine how solar panels affect wind (Figure 13). According to the response history study, code-design-level winds under uplift can be withstood by a flexible solar array support system with a sufficient ballast weight or attachments, especially at the edges and corners of the array, and suitable structural connections.
Yuan [78] et al. used a dynamic analysis method to simulate the dynamic response of a PV steel panel support under strong winds. A new calculation method for the design of PV steel structures and a basis for the study of their dynamic performance and structural optimization was provided. Xu [79,80] et al. used the finite element program ABAQUS to investigate the wind-induced vibration coefficient of a fish-belly PV cable truss structural support. The numerical analysis results of the dynamic wind load obtained a large discrete-type displacement–wind–vibration coefficient, suggesting the practicality of using stress–wind–vibration coefficients. In an experiment, Gong [81] et al. examined a rigid heliostat model subjected to three-dimensional wind loads in a wind tunnel. The findings of the measurements made by Peterka et al. were compared with the maximum wind force coefficients that were obtained and the corresponding wind directions. Based on the results of the analysis, a desirable stow location was recommended to withstand wind loads. Tamura [82] et al. described the wind-induced vibration of a solar wing system obtained in wind tunnel experiments and investigated its aeroelastic instability using a scaled model. In order to investigate the flow characteristics surrounding solar arrays installed on a flat roof building (Figure 14) for two typical wind directions and elucidate the relationships between the flow field and wind pressure distributions on solar panels, Wang [83,84] et al. conducted extensive eddy simulations. It was concluded that the PV panel was more prone to vibration when its back was facing the wind. Liu [85] et al. studied a typical solar panel structure while considering an equivalent static wind load. A reference for the design of solar energy structures was thus provided by comparing the displacement and stress of the structure under various working conditions and determining the impact of the wind load on the structure.
Future research should lessen the effect of the wind load on the wind-induced vibration of PV power generation systems, consequently increasing the efficiency of PV power generation systems, to address the detrimental effect of wind loads on panel PV supports.

3.2. Example Analysis

According to the comparison of the advantages and disadvantages of fixed PV supports, flexible PV supports, and floating PV supports in Figure 1, the scope of application of fixed PV supports and floating PV supports is relatively limited; a fixed PV support is only suitable for flat terrain, and a floating PV support is only suitable for flat or sea level water, while the flexible PV support has a broader range of application. It is applicable in harsh terrain but is affected by the wind load; a flexible PV support makes it easy to produce wind-induced vibration. Thus, an analysis is conducted on a flexible PV support’s wind-induced vibration.

3.2.1. Numerical Model

Firstly, a refined model of the flexible PV support was established (Figure 15). The model comprises a horizontal load-bearing structure, beam structure, cable structure, tripod structure, and PV panel. Because of the three horizontal load-bearing structures, three models, such as a horizontal load-bearing structure of the cable, an inclined steel column horizontal load-bearing structure, and a horizontal force-bearing structure with eight inclined steel columns, are generated. In this paper, the span of the flexible PV support is 8 m, and the height is 2.6 m. In the horizontal load-bearing structure, the base size is 500 mm × 500 mm × 500 mm and the column structure’s size is 200 mm × 200 mm × 2400 mm; the beam structure’s size is 2000 mm × 200 mm × 200 mm; the cable structure’s length is 8 m; the tripod’s size is 1420 mm × 820 mm × 200 mm; and the PV panel structure’s size is 1640 mm × 992 mm × 48 mm.

3.2.2. Material Parameters

In this simulation experiment, concrete material is used as the foundation. The columns and beams in the horizontal load-bearing structure are all made of structural steel. The tripod structure adopts aluminum alloy material; the PV panels are made of PV materials; each material is an isotropic elastic material; and all components are assigned corresponding material properties (each material’s properties are shown in Table 3).

3.2.3. Simulation Results

This paper uses the ANSYS finite element analysis software to load wind loads on the three horizontal load-bearing structural models. The wind load direction is horizontal, and the wind load value is constantly increased to extract the ultimate wind loads of the three horizontal load-bearing structural models. The final simulation results are shown in Figure 16.
The maximum displacement of the three horizontal load-bearing structural models when they reach the ultimate bearing capacity is around 12.4 mm, as seen by comparing the above three simulation results. Therefore, to ensure safety, the displacement should be limited to 12.4 mm. At this time, the ultimate wind loads of the three models were extracted and compared (Figure 17).
Three types of ultimate wind loads are obtained through the concrete analysis of the three types of flexible PV support structure. Through the comparative analysis of these three wind loads, it is concluded that the ultimate wind load of the horizontal load-bearing structure of the cable is the smallest, the ultimate wind load of the horizontal force-bearing structure with eight inclined steel columns is the largest, and the ultimate wind load of the inclined steel column horizontal load-bearing structure is similar to that of the horizontal force-bearing structure with eight inclined steel columns. Therefore, the horizontal force-bearing structure with eight inclined steel columns and the inclined steel column horizontal load-bearing structure are more reliable. However, compared with the inclined steel column horizontal load-bearing structure, the horizontal force-bearing structure with eight inclined steel columns is more complicated, and the cost is higher, so the inclined steel column horizontal load-bearing structure is safer, more reliable, and economical, and the loading characteristics of the inclined steel column horizontal load bearing structure need to be further studied. In summary, the inclined steel column horizontal load-bearing structure is the best choice to reduce the wind vibration of the flexible PV support.

3.2.4. Discussion

The wind load is a vital load affecting PV supports, and the harm caused by wind-induced vibration due to wind loads is enormous. Aiming at the wind-induced vibration of flexible PV supports, a PV building integration technology [86,87] was proposed to reduce the harm caused by wind vibration. PV building integration (Figure 18) is a technology that integrates solar power generation products into buildings. Because of this characteristic, it offers a measure to avoid wind-induced vibration during PV power generation. However, at the same time, its application range is also relatively narrow, only some buildings are suitable for PV building integration, and it will also produce a series of problems, such as temperature problems [88].
There is also a unified active roof wind design method [89] that defines the fixtures of these products and suggests rules for the design of substructures against wind loads, but, so far, this technology has yet to be developed.

4. Calculation of Wind Load of PV Panel Support

The wind load is the most significant load when designing a PV support; thus, its value and calculation should be investigated. Different countries have their own specifications and, consequently, equations for the wind loads of PV supports. Zou [90] et al. compared the main parameters of the wind load in relevant local and international regulations used for the wind load calculation of the fixed supports of PV structures. The findings demonstrated that different regulations’ restrictions on the wind load on PV installations fluctuate significantly, leading to various wind load values. Two recognized techniques for the determination of wind loads on structures—such as solar panels—were introduced by Banks [91] in the United States. Meanwhile, Zhao [92] et al. conducted a comparative analysis of the most widely used Chinese, American, European, and Japanese codes for PV wind load calculation methods. In particular, the similarities and differences in the wind load calculation factors and their correction coefficients for each code were compared and investigated. The Chinese, American, European, and Japanese codes were noted to consider the ground roughness category, topographic conditions, wind pressure height variations, and wind vibration coefficients, but there were differences in the correction coefficients used for different countries. Thus, He [93] et al. proposed a new wind load distribution model for PV arrays (Figure 19) based on the comparison between the Japanese and Chinese codes and combined this with the results of wind tunnel experiments for a more accurate evaluation of the wind load on a PV array and for the determination of the actuator axial force of tracking systems.
Wind tunnel studies were conducted by Kopp [94] et al. to determine the design wind load for rooftop solar arrays. Meanwhile, based on a compilation of wind tunnel experiments carried out by RWDI using rigid pressure models, Browne [95] et al. presented a succinct method to determine the design wind loads for multi-row ground-mounted solar arrays, including both static and dynamic wind load coefficients compatible with ASCE 7. Yang [96] et al. established a wind load calculation model for tracking supports based on the national standard analysis of the heterogeneous loads of PV panel supports. This method offers clear direction for the PV tracking support’s optimization. Further, the developed MATLAB 2021b calculation tool can conveniently and efficiently calculate the PV wind load. Three wind load models, namely the uniform distribution, trapezoidal distribution, and eccentric moment models, were developed by Ma [97] et al. in terms of the structural features of a solar panel. Gao [98] et al. used computational calculations and wind tunnel testing to investigate the wind field properties of a PV panel support unit. The outcomes demonstrated that the PV panel’s wind load influence variables were parameterized. Additionally, formulas for wind loads were derived together with examples, providing a guide for the design of wind-resistant PV structures. Zhang [99] et al. used Labview and a pull-pressure sensor to analyze the pulling and pressing on PV panels. Subsequently, the results were compared with those of previous numerical analysis and verification experiments, providing the basis for the strength design of PV panels and their tipping moment calculation. The wind load of floating PV arrays (Figure 20) was simulated by Chen [100] et al. by CFD. The variation rule of the wind load under different directions was obtained to verify the accuracy of the design specifications. According to the results, the first row of upwind PV arrays was primarily affected by the wind load. Consequently, improvement measures were established based on the results. Thus, this study is essential for the design and optimization of PV panel arrays and the correct selection of the wind load in the anti-wind design of solar panels. Han [101] et al. utilized a rigid model wind tunnel test of the wind load distribution of a single set of ground-mounted PV panels. Subsequently, recommended values were obtained for the test operation of a single set of PV panels, a PV panel array, and a rooftop PV panel with different parapet heights. The detailed calculation formula for the wind load is shown in Table 4.

5. Conclusions

(1)
For PV support structures, the most critical load is the wind load; the existing research only focuses on the panel inclination angle, wind direction angle, body type coefficient, geometric scale, shielding effect, template gap, and other single factors that impact the wind loads of PV support structures. Future work should consider the comprehensive impact of the above factors for the wind-resistant design of PV support structures.
(2)
The wind-induced vibration caused by wind loads is one of the main reasons for the failure of PV supports, so the research focus is not only to improve the power generation efficiency of PV systems but also to reduce the wind-induced vibration of PV support structures.
(3)
The wind load is an essential load in the PV support structure, so determining the wind load is critical. The existing wind load calculation formulas for PV support structures have their limitations. In the future, the wind load calculation formulas of PV support structures should be further improved based on their predecessors to better achieve the wind-resistant design of PV support structures.

Author Contributions

Conceptualization, Y.J. and B.N.; validation, Y.J. and Y.C.; writing—original draft preparation, Y.J., B.N. and Y.C.; writing—review and editing, Y.J., B.N. and Y.C.; visualization, Y.B. and Y.J.; supervision, Y.J.; project administration, Y.J.; funding acquisition, B.N. and Y.J. All authors have read and agreed to the published version of the manuscript.

Funding

Basic Scientific Research Project of Colleges and Universities of Liaoning Province (LJKZ0698); Scientific Research Funding Project of Liaoning Province, China (Grant number: LJKZ0689).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

NotationDescription
W the design wind load
ω k the standard value of the wind load
ω 0 the basic wind pressure
μ s the body type coefficient of the wind load
μ z the wind pressure height coefficient
β z the wind vibration coefficient
A W the wind area
p the design wind pressure
G the gust coefficient
C N the body type coefficient of the wind load
q h the velocity of the wind pressure at a given altitude
P t o t a l the total wind pressure
P ¯ n e t the mean wind pressure
P ˜ n e t the standard deviation of the wind pressure
g B _ p the resonant peak factor
g R _ p the resonant peak factor
D A F p the dynamic amplification factors associated with the normal force
W k the design wind load
c p m e a n the average wind pressure coefficient
μ z the height coefficient
φ p the position coefficient
φ β the wind direction angle factor
φ α the dip coefficient
A the wind area
V the wind speed

References

  1. Bouich, A.; Pradas, I.G.; Khan, M.A.; Khattak, Y.H. Opportunities, Challenges, and Future Prospects of the Solar Cell Market. Sustainability 2023, 15, 15445. [Google Scholar] [CrossRef]
  2. Huang, H.; Zhang, M.; He, Y. Experimental Study on Bearing Load-carrying Capacity of Fixed Photovoltaic Bracket. Acta Energiae Solaris Sin. 2020, 41, 7–13. [Google Scholar]
  3. Tang, J.; Lin, J.; Huo, J. Structural Characteristics Analysis and Optimal Design of Flexible Photovoltaic Support Structure. J. Huaqiao Univ. 2019, 40, 331–337. [Google Scholar] [CrossRef]
  4. Yuan, W.; Lu, H.; Pan, T. Research on the Structural Dynamics of Floating Photovoltaic (PV) System under the Condition with Wind and Wave Coupled. Eng. J. Wuhan Univ. 2021, 54, 7–13. [Google Scholar]
  5. Wu, J.; Liang, T.; Mi, W. Analysis of Development and Application Prospect of Floating Photovoltaic Power Station on Water. Sol. Energy 2019, 20–23. [Google Scholar]
  6. Li, C. Structure Design and Engineering Application of Flexible Photovoltaic Support System. Archit. Technol. 2021, 52, 1120–1122. [Google Scholar]
  7. Song, K.; Wang, L.; Fan, J. Numerical Study of Heat Transfer Enhancement of Finned Flat Tube Bank Fin with Vortex Generators Mounted on both Surfaces of the Fin. Heat Mass Transf. 2008, 44, 959–967. [Google Scholar] [CrossRef]
  8. Wongwuttanasatian, T.; Sarikarin, T.; Suksri, A. Performance Enhancement of a Photovoltaic Module by Passive Cooling Using Phase Change Material in a Finned Container Heat Sink. Sol. Energy 2020, 195, 47–53. [Google Scholar] [CrossRef]
  9. Liu, X.; Cui, G.; Yu, K. Study on Flexible Solar Photovoltaic Support System. China’s New Technol. New Prod. 2020, 2, 79–81. [Google Scholar] [CrossRef]
  10. Ma, X.; Yu, H.; Zhang, D.; Li, G.; Wan, J.; Cai, D. Analysis of the development trend of surface photovoltaic industry. Sol. Energy. 2023, 5–12. [Google Scholar] [CrossRef]
  11. Cuce, E.; Cuce, P.M.; Saboor, S.; Ghosh, A.; Sheikhnejad, Y. Floating PVs in Terms of Power Generation, Environmental Aspects, Market Potential, and Challenges. Sustainability 2022, 14, 2626. [Google Scholar] [CrossRef]
  12. Zhan, Y.; Yu, Z.; Liu, X. Research and Application of Floating PV Power Generation System under Resource-intensive Conditions. Sol. Energy 2023, 56–61. [Google Scholar] [CrossRef]
  13. Wang, C.; Ma, W.; Han, L.; Gao, F. Effect of Parapet on Wall Load of Flat Roof Array Solar Panel. Eng. Mech. 2021, 38, 216–222. [Google Scholar] [CrossRef]
  14. Ma, W.; Ma, C.; Wang, C. Wind Tunnel Experimental Study on the Wind Load Interference Effect of Solar Panel Arrays. J. Exp. Fluid Mech. 2021, 35, 19–25. [Google Scholar] [CrossRef]
  15. Ma, W.; Chai, X.; Ma, C. Experimental Study on Wind Load Influencing Factors of Flexible Support Photovoltaic Modules. J. Exp. Fluid Mech. 2021, 42, 10–18. [Google Scholar] [CrossRef]
  16. Li, S.; Liu, Z.; Zhang, X.; Fang, X.; Gao, W.; Sun, H. Wind Tunnel Tests for a Solar Parking Shed with a Mono-sloped Roof. J. Vib. Shock 2019, 38, 240–245+263. [Google Scholar] [CrossRef]
  17. Li, S.; Zhang, X.; Fang, X.; Sun, H.; Chen, N.; Hu, J. Wind Loads on Solar Car Parking Gable Shed. Acta Energiae Solaris Sin. 2019, 40, 530–537. [Google Scholar]
  18. Stathopoulos, T.; Zisis, I.; Xypnitou, E. Local and Overall Wind Pressure and Force Coefficients for Solar Panels. J. Wind Eng. Ind. Aerodyn. 2014, 125, 195–206. [Google Scholar] [CrossRef]
  19. Naeiji, A.; Raji, F.; Zisis, I. Wind Loads on Residential Scale Rooftop Photovoltaic Panels. J. Wind Eng. Ind. Aerodyn. 2017, 168, 228–246. [Google Scholar] [CrossRef]
  20. Qiao, X.; Gu, S.; Luo, X. Wind Load Distribution of Photovoltaic Bracket Array Based on Numerical Wind Tunnel. Comput. Aided Eng. 2018, 27, 51–56. [Google Scholar] [CrossRef]
  21. Kopp, G.A.; Farquhar, S.; Murrison, M.J. Aerodynamic Mechanisms for Wind Loads on Tilled, Roof-mounted, Solar arrays. J. Wind Eng. Ind. Aerodyn. 2012, 111, 40–52. [Google Scholar] [CrossRef]
  22. Naeiji, A.; Raji, F.; Zisis, I. Wind-Induced Pressures and Forces on Solar Panels Mounted on Flat, Gable or Hip Roof Residential Buildings. In Proceedings of the 14th International Conference on Wind Engineering, Porto Alegre, Brazil, 21–26 June 2015. [Google Scholar]
  23. Jiang, J.; Zhang, Z.; Lu, Y.; Lu, Y.; Zhang, T.; Zhang, J. Numerical Analysis of Wind Loads about Photovoltaic Arrays Considering Bending Moment. Renew. Energy Resour. 2019, 37, 46–52. [Google Scholar] [CrossRef]
  24. Yemenici, O.; Aksoy, M.O. An Experimental and Numerical Study of Wind Effects on a Ground-mounted Solar Panel at Different Panel Tilt Angles and Wind Directions. J. Wind Eng. Ind. Aerodyn. 2021, 213, 104630. [Google Scholar] [CrossRef]
  25. Du, H.; Xu, H.; Zhang, Y.; Lou, W. Wind Pressure Characteristics and Wind Vibration Response of Long-span Flexible Photovoltaic Support Structure. J. Harbin Inst. Technol. 2022, 54, 67–74. [Google Scholar] [CrossRef]
  26. Huang, Z.; Yan, H. Numerical Simulation of Group Shielding Effect of Solar Photovoltaic Panels under Wind Load. Spec. Struct. 2015, 32, 18–22. [Google Scholar]
  27. Li, J.; Qin, K.; Li, H. Numerical Wind Tunnel Simulation of Hami Shicheng Photovoltaic Industrial Park. Sol. Energy 2013, 19–22. [Google Scholar] [CrossRef]
  28. Yin, M.; Zou, Y.; Li, Q.; He, X.; Yan, L.; Han, G. Wind Tunnel Test Study on Wind Load of Single Row Tracking Photovoltaic Structure. J. Railw. Sci. Eng. 2020, 17, 2354–2362. [Google Scholar] [CrossRef]
  29. Xu, N.; Li, X.; Gao, C.; Zhu, C.; Zhou, Z.; Zhu, X. Analysis of Shape Coefficients of Wind Loads of Photovoltaic System. Acta Energiae Solaris Sin. 2021, 42, 17–22. [Google Scholar] [CrossRef]
  30. Jubayer, C.M.; Hangan, H. Numerical Simulation of Wind Effects on a Stand-alone Ground Mounted Photovoltaic (PV) system. J. Wind Eng. Ind. Aerodyn. 2014, 134, 56–64. [Google Scholar] [CrossRef]
  31. Shademan, M.; Barron, M.R.; Balachanda, R.; Hangan, H. Numerical Simulation of Wind Loading on Ground-mounted Solar Panels at Different Flow Configurations. Can. J. Civ. Eng. 2014, 41, 728–738. [Google Scholar] [CrossRef]
  32. Shademan, M.; Horia, H. Wind Loading on Solar Panels at Different Inclination Angles. In Proceedings of the 11th Americas Conference on Wind Engineering, San Juan, Puerto Rico, 22–26 June 2009. [Google Scholar]
  33. Huang, Z.; Yang, G.; Han, X.; Wang, Q. CFD Numerical Analysis of Wind Pressure Distribution Characteristics of Solar Photovoltaic Panel under Dual Array Layout; Tianjin University: Tianjin, China, 2016; pp. 1878–1883. [Google Scholar]
  34. Niu, B.; Zhuang, C.; Hou, W.; Wang, L.; Ma, L.; Qi, W. Time History Analysis of Wind Load on Arrayed Solar Panels Based on CFD Simulations. Acta Energiae Solaris Sin. 2016, 37, 1774–1779. [Google Scholar]
  35. Wang, C.; Ma, W.; Han, X.; Gao, F. Influence of Parapet on Wind Load on Array PV Panels on the Roof; Wuhan University of Technology: Wuhan, China, 2020; pp. 252–256. [Google Scholar] [CrossRef]
  36. Huang, B.; Ma, W.; Liu, Q.; Liu, X.; Xing, K. Study on the Effect of Sheelding Tandem Photovoltaic Panels Shape Coeffcient. In Proceedings of the National Structural Engineering Academic Conference, Jinan, China, 14–16 August 2016. [Google Scholar]
  37. Huang, Z.; Zuo, C. Numerical Simulation of Wind Load Shape Coefficient of Photovoltaic Panel for Solar Tracker. Spec. Struct. 2014, 31, 101–107. [Google Scholar]
  38. Wang, D.; Wang, L.; Fang, W. Study on Shape Coefficient of Group Photovoltaic Support Based on Wind Tunnel Test and Numerical Simulation. Spec. Struct. 2020, 37, 42–46. [Google Scholar] [CrossRef]
  39. Aly, A.M.; Bitsuamlak, G. Aerodynamic Pressures on Ground Mounted Solar Panels: Test Model Scale Effects. In Proceedings of the 2012 International Conference on Advances in Wind and Structures (AWAS’12), Seoul, Republic of Korea, 20–26 August 2012. [Google Scholar]
  40. Aly, A.M.; Bitsuamlak, G. Aerodynamics of Ground-mounted Solar Panels: Test Model Scale Effects. J. Wind. Eng. Ind. Aerodyn. 2013, 123, 250–260. [Google Scholar] [CrossRef]
  41. Aly, A.M. On the Evaluation of Wind Loads on Solar Panels: The scale issue. Sol. Energy 2016, 135, 423–434. [Google Scholar] [CrossRef]
  42. Kopp, G.A. Wind Loads on Low-profile, Tilted, Solar Arrays Placed on Large, Flat, Low-rise Building Roofs. J. Struct. Eng. 2014, 140, 4013057. [Google Scholar] [CrossRef]
  43. Alrawashdeh, H.; Stathopoulos, T. Wind Loads on Solar Panels Mounted on Flat Roofs: Effect of geometric scale. J. Wind Eng. Ind. Aerodyn. 2020, 206, 104339. [Google Scholar] [CrossRef]
  44. Fang, Y.; Zhang, G.; Tang, W. Study on the Numerical Simulation of Solar Photovoltaic Panels Array of Wind Pressure Characteristics. Electr. Power Surv. Des. 2018, 4, 76–80. [Google Scholar] [CrossRef]
  45. Bitsuamlak, G.T.; Dagnew, A.K.; Erwin, J. Evaluation of Wind Loads on Solar Panel Modules Using CFD. In Proceedings of the Fifth International Symposium on Computational Wind Engineering, Chapel Hill, NC, USA, 23–27 May 2010; pp. 23–27. [Google Scholar]
  46. Radu, A.; Axinte, E.; Theohari, C. Steady Wind Pressures on Solar Collectors on Flat-roofed Buildings. J. Wind Eng. Ind. Aerodyn. 1986, 23, 249–258. [Google Scholar] [CrossRef]
  47. Lou, W.; Shan, H.; Yang, Z. Study of Shielding Effect on Shape Coefficient of Super-large Photovoltaic Arrays. J. Build. Struct. 2021, 42, 47–54. [Google Scholar] [CrossRef]
  48. Ruan, H.; Liao, W.; Wang, K.; Zhao, Y. Numerical Research on Surface Wind Load of PV Array. Acta Energiae Solaris Sin. 2015, 36, 871–877. [Google Scholar]
  49. Abiola-Ogedengbe, A.; Hangan, H.; Siddiqui, K. Experimental Investigation of Wind Effects on a Standalone Photovoltaic (PV) Module. Renew. Energy 2015, 78, 657–665. [Google Scholar] [CrossRef]
  50. Stenabaugh, S.E.; Yumi, I.; Kopp, G.A.; Karava, P. Wind Loads on Photovoltaic Arrays Mounted Parallel to Sloped Roofs on Low-rise Buildings. J. Wind Eng. Ind. Aerodyn. 2015, 139, 16–26. [Google Scholar] [CrossRef]
  51. Yemenici, O. Experimental Study of Aerodynamic Loads on Ground-mounted Solar Panel Arrays: The Panel Spacing and Inclination Angle Effect. Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci. 2020, 234, 3380–3396. [Google Scholar] [CrossRef]
  52. Shademan, M.; Balachandar, R.; Barron, R.M. Detached Eddy Simulation of Flow Past an Isolated Inclined Solar Panel. Fluids Struct. 2014, 50, 217–230. [Google Scholar] [CrossRef]
  53. Warsido, W.P.; Bitsuamlak, G.T.; Barata, J.; Chowdhury, A.G. Influence of Spacing Parameters on the Wind Loading of Solar Array. J. Fluids Struct. 2014, 48, 295–315. [Google Scholar] [CrossRef]
  54. Cao, J.; Yoshida, A.; Saha, P.K.; Tamura, Y. Wind Loading Characteristics of Solar Arrays Mounted on Flat Roofs. J. Wind Eng. Ind. Aerodyn. 2013, 123, 214–225. [Google Scholar] [CrossRef]
  55. Wood, G.S.; Denoon, R.O.; Kwok, K.C.S. Wind Loads on Industrial Solar Panel Arrays and Supporting Roof Structure. Wind Struct. 2001, 4, 481–494. [Google Scholar] [CrossRef]
  56. Geurts, C.; Blackmore, P. Wind Loads on Stand-off Photovoltaic Systems on Pitched Roofs. J. Wind Eng. Ind. Aerodyn. 2013, 123, 239–249. [Google Scholar] [CrossRef]
  57. He, J.; Zhu, R.; Wang, J. Numerical Simulation of Wind Load on Photovoltaic Panels. Sol. Energy 2013, 16, 56–58. [Google Scholar]
  58. Erwin, J.; Bitsuamlak, G.; Chowdhury, A.G.; Barkaszi, S.; Gamble, S. Full Scale and Wind Tunnel Testing of a Photovoltaic Panel Mounted on Residential Roofs. In Advances in Hurricane Engineering: Learning from Our Past, Proceedings of the ATC & SEI Conference on Advances in Hurricane Engineering 2012, Miami, FL, USA, 24 October 2012; ASCE Press: Reston, VA, USA, 2013; pp. 471–482. [Google Scholar] [CrossRef]
  59. Pfahl, A.; Buselmeier, M.; Zaschke, M. Wind Loads on Heliostats and Photovoltaic Trackers of Various Aspect Ratios. Sol. Energy 2011, 85, 2185–2201. [Google Scholar] [CrossRef]
  60. Wang, J.; Yang, Q.; Tamura, Y. Effects of Building Parameters on Wind Loads on Flat-roof-mounted Solar Arrays. J. Wind Eng. Ind. Aerodyn. 2018, 174, 210–224. [Google Scholar] [CrossRef]
  61. Ma, W.; Chai, X.; Liu, Q.; Xing, K.; Liu, X. Study on Effect of Bottom Flow Obstruction on Wind Load of Solar Photovoltaic Panels. Build. Struct. 2019, 49, 129–134. [Google Scholar] [CrossRef]
  62. Ma, W.; Chai, X.; Zhao, H.; Ma, C. A Study on Distribution Coefficient of a Flexible Photovoltaic Support Cable Based on an Eccentric Moment Wind Load Distribution Model. J. Vib. Shock 2021, 40, 305–310. [Google Scholar] [CrossRef]
  63. Dai, S.F.; Liu, H.J.; Yang, J.H.; Peng, H.Y. Wind Loads on Roof-mounted Isolated Solar Panels of Tall Buildings through Wind Tunnel Testing. Sol. Energy 2022, 231, 607–622. [Google Scholar] [CrossRef]
  64. Zhang, D.; Chang, F. Analysis of Wind Loads on Ground-mounted PV Arrays with Wall Shielding. J. Shenyang Aerosp. Univ. 2019, 36, 41–49. [Google Scholar]
  65. Browne, M.T.L.; Gibbons, M.P.M.; Camble, S.; Galsworthy, J. Wind Loading on Titled Roof-top Solar Arrays: The Parapet Effect. J. Wind Eng. Ind. Aerodyn. 2013, 123, 202–213. [Google Scholar] [CrossRef]
  66. Banks, D. The Role of Corner Vortices in Dictating Peak Wind Loads on Tilted Flat Solar Panels Mounted on Large Flat Roofs. Wind Eng. Ind. Aerodyn. 2013, 123, 192–201. [Google Scholar] [CrossRef]
  67. Pratt, R.N.; Kopp, G.A. Velocity Measurements around Low-profile, Tilted, Solar Arrays Mounted on Large Flat-roofs, for Wall Normal Wind Directions. J. Wind Eng. Ind. Aerodyn. 2013, 123, 226–238. [Google Scholar] [CrossRef]
  68. Wang, J.; Yang, Q.; Liu, M.; Zhang, J. Experimental Research on Characteristics of Wind Loads of Solar Arrays Mounted on Flat and Gable Roofs. J. Build. Struct. 2018, 39, 21–28. [Google Scholar] [CrossRef]
  69. Aly, A.M.; Bitsusmlak, G. Wind-induced Pressures on Solar Panels Mounted on Residential Homes. J. Archit. Eng. 2014, 20, 4013003. [Google Scholar] [CrossRef]
  70. Górecki, K.; Dąbrowski, J.; Krac, E. SPICE-Aided Modeling of Daily and Seasonal Changes in Properties of the Actual Photovoltaic Installation. Energies 2021, 14, 6247. [Google Scholar] [CrossRef]
  71. Ma, C. Study on Wind Load Characteristics and Wind-Induced Response of Solar Photovoltaic Panels; Shijiazhuang Tiedao University: Shijiazhuang, China, 2021. [Google Scholar]
  72. He, X.; Ding, H.; Jing, H.; Zhang, F.; Wu, X.; Wen, X. Wind-induced Vibration and its Suppression of Photovoltaic Modules Supported by Suspension Cables. J. Wind Eng. Ind. Aerodyn. 2020, 206, 104275. [Google Scholar] [CrossRef]
  73. Jubayer, C.M.; Hangan, H. A Numerical Approach to the Investigation of Wind Loading on an Array of Ground Mounted Solar Photovoltaic (PV) Panels. J. Wind Eng. Ind. Aerodyn. 2016, 153, 60–70. [Google Scholar] [CrossRef]
  74. Li, S.; Ma, J.; Liu, J.; Chen, Z. Experimental Study for Flutter Performance of Flexible Photovoltaic System by Segmental Model Test. China Civ. Eng. J. 2023, 36, 1–8. [Google Scholar] [CrossRef]
  75. Wang, Z.; Zhao, F.; Ji, C.; Peng, X.; Lu, H. Analysis of Vibration Control of Multi-row Large-span Flexible Photovoltaic Supports. Eng. J. Wuhan Univ. 2020, 53, 29–34. [Google Scholar]
  76. Wang, Z.; Zhao, F.; Ji, C.; Peng, X.; Lu, H. Wind-induced Vibration Analysis of Multi-row and Multi-span Flexible Photovoltaic Support. Eng. J. Wuhan Univ. 2021, 54, 75–79. [Google Scholar]
  77. Schellenberg, A.; Maffei, J.; Telleen, K.; Ward, R. Structural Analysis and Application of Wind Loads to Solar Arrays. J. Wind Eng. Ind. Aerodyn. 2013, 123, 261–272. [Google Scholar] [CrossRef]
  78. Yuan, T.; Liu, S.; Wang, S. FEM Analysis of Photovoltaic Steel Structure Support in the Gale Based on Force Time-history Analysis Method. In Proceedings of the 12th China CAE Annual Conference 2016, Chengdu, China, 31 August 2016; pp. 184–188. [Google Scholar]
  79. Xu, Z.; Hou, G.; Zhang, Z.; Wang, W.; Fan, H.; Shi, J. Numerical Analysis of Wind Vibration Coefficient of Fish Bellied Photovoltaic Cable Truss. Sol. Energy 2019, 46–49+18. [Google Scholar] [CrossRef]
  80. Xu, Z. Numerical Analysis of Wind-induced Response of Fish Bellied Photovoltaic Cable Truss. In Proceedings of the 2020 Industrial Architecture Academic Exchange Conference; Building Research Institute of China Metallurgical Co., Ltd.: Shangai, China, 2020; Volume 2, pp. 363–365+257. [Google Scholar] [CrossRef]
  81. Gong, B.; Li, Z.; Wang, Y. Wind-induced Dynamic Response of Heliostat. Renew. Energy 2012, 38, 206–213. [Google Scholar] [CrossRef]
  82. Tamura, Y.; Kim, Y.C.; Yoshida, A.; Itoh, T. Wind-induced Vibration Experiment on Solar Wing. MATEC Web Conf. EDP Sci. 2015, 24, 4006. [Google Scholar] [CrossRef]
  83. Wang, J.; Phuc, P.V.; Yang, Q.; Tamura, Y. LES Study of Wind Pressure and Flow Characteristics of Flat-roof-mounted Solar Arrays. J. Wind Eng. Ind. Aerodyn. 2020, 198, 104096. [Google Scholar] [CrossRef]
  84. Wang, J.; Yang, Q.; Phuc, P.V.; Tamura, Y. Characteristics of Conical Vortices and their Effects on Wind Pressures on Flat-roof-mounted Solar Arrays by LES. J. Wind Eng. Ind. Aerodyn. 2020, 200, 104146. [Google Scholar] [CrossRef]
  85. Liu, C.; Bai, B.; Li, L. Response Analysis of Equivalent Static Wind Load of Solar Panel Support System. Shanxi Archit. 2017, 43, 45–47. [Google Scholar] [CrossRef]
  86. Liu, B.; Duan, S.; Cai, T. Photovoltaic DC-building-module Based BIPV System: Concept and Design Considerations. IEEE Trans. Power Electron. 2010, 26, 1418–1429. [Google Scholar] [CrossRef]
  87. Chen, L.; Zheng, X.; Yang, J.; Yoon, J. Impact of BIPV Windows on Building Energy Consumption in Street Canyons: Model Development and Validation. Energy Build. 2021, 249, 111207. [Google Scholar] [CrossRef]
  88. Azhar, M.H.A.; Alhammadi, S.; Jang, S.; Kim, J.; Kim, J.; Kim, W.K. Long-Term Field Observation of the Power Generation and System Temperature of a Roof-Integrated Photovoltaic System in South Korea. Sustainability 2023, 15, 9493. [Google Scholar] [CrossRef]
  89. Eu, F.E. Wind Loads on Solar Energy Roofs. Heron 2007, 52, 201–222. [Google Scholar]
  90. Zou, Y.; Li, Q.; Yin, M.; He, X.; Yan, L.; Liu, Y. Comparison of Wind Load Standard Values of Tracking Photovoltaic (PV) Structure with Wind Tunnel Test Values. J. Cent. South Univ. 2022, 53, 1331–1340. [Google Scholar] [CrossRef]
  91. Banks, D. How to Calculate Wind Loads on Roof Mounted Solar Panels in the US. 2007. Available online: https://www.cppwind.com/wp-content/uploads/2014/03/HowToCalculateWindLoads.pdf (accessed on 21 November 2013).
  92. Zhao, Y.; Wang, L.; Dou, H. Comparative Analysis of Sino-foreign Codes on Wind Load Calculation Methods for Photovoltaic Panels. J. Water Resour. Archit. Eng. 2022, 20, 182–187. [Google Scholar] [CrossRef]
  93. He, G.; Jiang, H.; Shan, J.; Zhou, A. Research of Wind Load Model in Photovoltaic Array. Electr. Power Des. 2012, 33, 5–8. [Google Scholar] [CrossRef]
  94. Kopp, G.A.; Banks, D. Use of the Wind Tunnel Test Method for Obtaining Design Wind Loads on Roof-mounted Solar Arrays. J. Struct. Eng. 2013, 139, 284–287. [Google Scholar] [CrossRef]
  95. Browne, M.T.L.; Taylor, Z.J.; Li, S.; Gamble, S. A Wind Load Design Method for Ground-mounted Multi-row Solar Arrays Based on a Compilation of Wind Tunnel Experiments. J. Wind Eng. Ind. Aerodyn. 2020, 205, 104294. [Google Scholar] [CrossRef]
  96. Yang, L.; Yu, H.; Lin, L. Study on Wind Load Calculation Method of Photovoltaic Power Array. J. Energy Environ. 2021, 70–72. [Google Scholar] [CrossRef]
  97. Ma, W.; Sun, G.; Liu, X.; Xing, K.; Liu, Q. Tests for Wind Load Distribution Model of Solar Panels. J. Vib. Shock 2017, 36, 8–13. [Google Scholar] [CrossRef]
  98. Gao, L.; Dou, Z.; Bai, H.; Li, J. Analysis of Influence Factors for Wind Lode of PV Module. Acta Energiae Solaris Sin. 2016, 37, 1931–1937. [Google Scholar]
  99. Zhang, Q.; Liu, Z.; Qi, X.; Jia, L. Solar Photovoltaic Panels Wind Load Testing and Analysis. Energy Technol. 2010, 31, 93–95. [Google Scholar]
  100. Chen, Y.; Wang, J. Design Optimization and Numerical Analysis of Wind Load for Large Water Surface Photovoltaic Power Station. J. Guangdong Univ. Petrochem. Technol. 2021, 31, 33–35+39. [Google Scholar]
  101. Han, X. Study on Wind Load Value of Solar Photovoltaic Array; Shijiazhuang Tiedao University: Shijiazhuang, China, 2016. [Google Scholar]
Figure 1. Comparison of advantages and disadvantages of three types of PV supports.
Figure 1. Comparison of advantages and disadvantages of three types of PV supports.
Sustainability 16 02551 g001
Figure 2. Factors affecting wind load of PV support.
Figure 2. Factors affecting wind load of PV support.
Sustainability 16 02551 g002
Figure 3. Panel inclination angle diagram.
Figure 3. Panel inclination angle diagram.
Sustainability 16 02551 g003
Figure 4. Single-slope PV carport.
Figure 4. Single-slope PV carport.
Sustainability 16 02551 g004
Figure 5. Double-slope PV carport.
Figure 5. Double-slope PV carport.
Sustainability 16 02551 g005
Figure 6. Wind direction angle diagram.
Figure 6. Wind direction angle diagram.
Sustainability 16 02551 g006
Figure 7. PV model with adjustable inclination angle.
Figure 7. PV model with adjustable inclination angle.
Sustainability 16 02551 g007
Figure 8. Boundary-layer wind tunnel 1:50, 1:100, 1:200 test model.
Figure 8. Boundary-layer wind tunnel 1:50, 1:100, 1:200 test model.
Sustainability 16 02551 g008
Figure 9. BRE wind tunnel view.
Figure 9. BRE wind tunnel view.
Sustainability 16 02551 g009
Figure 10. Installation drawing of a rigid model wind tunnel.
Figure 10. Installation drawing of a rigid model wind tunnel.
Sustainability 16 02551 g010
Figure 11. Boundary-layer wind tunnel test configuration diagram.
Figure 11. Boundary-layer wind tunnel test configuration diagram.
Sustainability 16 02551 g011
Figure 12. Wind vibration damage of PV support.
Figure 12. Wind vibration damage of PV support.
Sustainability 16 02551 g012
Figure 13. Response-history analysis chart.
Figure 13. Response-history analysis chart.
Sustainability 16 02551 g013aSustainability 16 02551 g013b
Figure 14. Schematic view of flat-roof-mounted solar arrays.
Figure 14. Schematic view of flat-roof-mounted solar arrays.
Sustainability 16 02551 g014
Figure 15. Fine model of flexible PV support.
Figure 15. Fine model of flexible PV support.
Sustainability 16 02551 g015
Figure 16. Comparison of the total deformation of the three models. (a) Maximum displacement of the cable model. (b) Maximum displacement of the inclined steel column model. (c) Maximum displacement of the model with eight inclined steel columns.
Figure 16. Comparison of the total deformation of the three models. (a) Maximum displacement of the cable model. (b) Maximum displacement of the inclined steel column model. (c) Maximum displacement of the model with eight inclined steel columns.
Sustainability 16 02551 g016
Figure 17. Comparison of the ultimate wind loads of three models.
Figure 17. Comparison of the ultimate wind loads of three models.
Sustainability 16 02551 g017
Figure 18. PV building integration project.
Figure 18. PV building integration project.
Sustainability 16 02551 g018
Figure 19. A new wind load distribution model for PV arrays.
Figure 19. A new wind load distribution model for PV arrays.
Sustainability 16 02551 g019
Figure 20. Floating PV array.
Figure 20. Floating PV array.
Sustainability 16 02551 g020
Table 1. Impact of various panel inclination angles on wind loads of PV supports.
Table 1. Impact of various panel inclination angles on wind loads of PV supports.
AuthorAngle of InclinationConclusionReference
Ma et al.10°, 30°The wind load increases as the inclination angle increases.[14]
Li et al.20°, 30°As the roof angle increases, so does the wind load.[16,17]
Stathopoulos et al.20°, 30°, 40°, 45°The panel inclination angle only has an effect in key wind directions.[18]
Naeiji et al.20°, 30°, 40°The factor that most significantly influences the peak pressure coefficient is the angle of panel inclination.[19]
Qiao et al.10°, 60°With varying inclination angles, the wind load’s form coefficient changes.[20]
Kopp et al.2°, 20°The array created turbulence at high inclination angles, which raised the net wind load. Meanwhile, pressure equalization predominated for small inclination degrees.[21]
Jiang et al.20°, 25°, 30°, 35°, 45°The installation angle affects the shape coefficient and bending moment coefficient of each PV array.[23]
Yemenici et al.25°, 45°The wind direction and panel inclination have a significant influence on the flow structure.[24]
Table 2. Impact of wind direction angle on wind loads of PV panel supports.
Table 2. Impact of wind direction angle on wind loads of PV panel supports.
AuthorWind Direction AngleConclusionReference
Du et al.0°, 180°The wind pressure on a flexible PV panel support increases as the wind azimuth increases.[25]
Huang et al.45°, 135°The wind load of tracker panels was higher than that of fixed panels owing to the large left–right clearance and the small length-to-height ratio at 45° and 135° wind direction angles.[26]
Yin et al.0°, 45°, 135°, 180°The wind direction angle and dip angle significantly influence the wind load of a PV support.[28]
Xu et al.0°, 180°When the wind angle was 0° and 180°, the second row of the PV panel array had the smallest size coefficient.[29]
Jubayer et al.0°, 180°For 0° and 180° winds, row 3 had the smallest wind load.[30]
Shademan et al.0°, 180°The structure’s wind load achieved its maximum value at 0° and 180° wind direction angles.[31]
Table 3. Material characteristics.
Table 3. Material characteristics.
Material NameDensity (kg/m3)Young’s Modulus (Pa)Poisson’s Ratio
Concrete23003 × 10100.18
Structural steel78502 × 10110.3
Aluminum alloy27707.1 × 10100.33
PV material26001.1 × 10110.225
Table 4. The calculation formula for the wind load.
Table 4. The calculation formula for the wind load.
AuthorFormulaCharacteristicReference
Zou et al. W = w k A w , w k = β z μ s μ z w 0 The dynamic effect of the wind must be considered.[90]
Zhao et al. p = q h G C N Short time interval and long recurrence period.[92]
He et al. W = w k 1 + w k 2 2 A w Close to the actual situation, conducive to the realization of PV structures with complex designs.[93]
Browne et al. P total = P ¯ n e t ± P ˜ n e t g B _ p 2 + g R _ P 2 DAF P 2 1 It is assumed that the wind deflection is slight and therefore the structure is inflexible.[95]
Yang et al. W k = 1 3 w k 1 + 2 3 w k 2 Computational models are more realistic.[96]
Gao et al. P = c p m e a n μ z φ p φ β φ α w 0 A It provides a reference for the wind-resistant design of solar PV structures.[98]
Zhang et al. W = 0.856 V 2 The fitting values are consistent with the empirical values.[99]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Nan, B.; Chi, Y.; Jiang, Y.; Bai, Y. Wind Load and Wind-Induced Vibration of Photovoltaic Supports: A Review. Sustainability 2024, 16, 2551. https://doi.org/10.3390/su16062551

AMA Style

Nan B, Chi Y, Jiang Y, Bai Y. Wind Load and Wind-Induced Vibration of Photovoltaic Supports: A Review. Sustainability. 2024; 16(6):2551. https://doi.org/10.3390/su16062551

Chicago/Turabian Style

Nan, Bo, Yuanpeng Chi, Yingchun Jiang, and Yikui Bai. 2024. "Wind Load and Wind-Induced Vibration of Photovoltaic Supports: A Review" Sustainability 16, no. 6: 2551. https://doi.org/10.3390/su16062551