Next Article in Journal
A Study on the Non-Linear Impact of Digital Technology Innovation on Carbon Emissions in the Transportation Industry
Previous Article in Journal
Adjunctive Bright Light Therapy for Non-Seasonal Major Depressive Disorder: A Randomized Controlled Trial
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Gaseous Air Pollutants and Respirable Crystalline Silica Inside and Outside Homes at Brick Kilns in Bhaktapur, Kathmandu Valley, Nepal

Department of Public Health, Brigham Young University, Provo, UT 84602, USA
*
Author to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2022, 19(19), 12431; https://doi.org/10.3390/ijerph191912431
Submission received: 2 August 2022 / Revised: 7 September 2022 / Accepted: 26 September 2022 / Published: 29 September 2022
(This article belongs to the Section Environmental Health)

Abstract

:
Household and ambient air pollution remain public health problems in much of the world. Brick kiln employees in Nepal may be particularly at risk of high air pollution exposures and resulting health effects due to high levels of outdoor air pollution, substandard housing, and indoor biomass cooking. We conducted a cross-sectional study of indoor and outdoor air pollution concentrations at workers’ homes at four fixed chimney Bull’s trench brick kilns in Bhaktapur, Kathmandu Valley, Nepal. We measured air concentrations of carbon monoxide (CO), carbon dioxide (CO2), nitrogen dioxide (NO2), sulfur dioxide (SO2), and respirable crystalline silica (SiO2; cristobalite, quartz, tridymite) using established methods and conducted a survey about characteristics of homes or samples that may be associated with air pollution concentrations. Geometric mean concentrations of CO, CO2, and SiO2 (quartz) were 0.84 ppm, 1447.34 ppm, and 6.22 µg/m3, respectively, whereas concentrations of all other air pollutants measured below lower detection limits. Most characteristics of homes or samples were not associated with air pollution concentrations. We found a positive association between the variable how long lived in house and SiO2 (quartz) concentrations, which may reflect sustained take-home exposure to SiO2 (quartz) over time. Interventions should focus on administrative controls to reduce take-home exposure to SiO2 (quartz) in this population.

1. Introduction

Brick workers in Nepal are a uniquely vulnerable population with regard to hazardous inhalation exposures. As a population, these workers experience almost constant exposure to hazardous air pollutants from (1) poor outdoor air quality in the Kathmandu Valley, (2) occupational brick dust containing respirable crystalline silica (SiO2), and (3) household air pollution (HAP) during non-working hours. Fine particulate matter (PM2.5) in the Kathmandu Valley regularly exceeds the 5.0 µg/m3 guideline recommended by the World Health Organization (WHO), often by an order of magnitude or more [1,2,3]. One prior study also documented occupational exposures to respirable crystalline SiO2 exceeding the permissible exposure limit (PEL) established by the U.S. Occupational Safety and Health Administration (OSHA) for all job categories that were studied [4]. Average exposures by job category ranged from 71–331 µg/m3. When brick workers are not working, they often live at the brick kiln in poorly constructed housing with limited ventilation [5]. Due to their impoverished conditions, brick workers and their families often use inexpensive solid fuels (e.g., wood) for cooking, which leads to high indoor HAP exposures [6,7]. The repeated daily triadic inhalation exposures likely explain why brick workers in Nepal report a high prevalence of symptoms consistent with a diagnosis of chronic obstructive pulmonary disease (COPD) [8].
Inhalation of HAP from burning solid fuels is a well-recognized risk factor for developing COPD, particularly among women, who spend more time with direct exposure to smoke from cooking fires [9,10]. Previous assessments of HAP in brick worker housing focused exclusively on PM2.5 and PM2.5 chemical constituents. Thygerson et al. sampled 16 homes at four different brick kilns in the Kathmandu Valley during daytime hours. The geometric mean (GM) indoor PM2.5 concentration did not differ significantly from the GM outdoor PM2.5 concentration, and both indoor and outdoor levels exceeded 180 µg/m3 [5]. A later study by Johnston et al. sampled PM2.5 over approximately 24 h. This study compared homes with wood cooking fires (n = 6) to those using cleaner-burning liquefied petroleum gas (LPG) cookstoves (n = 12) at a single brick kiln in Bhaktapur, Kathmandu Valley, Nepal [7]. Homes with wood cooking fires had significantly higher PM2.5 concentrations (GM: 541.14 µg/m3) than homes with LPG cookstoves (GM: 79.32 µg/m3) or outdoor air (GM 48.38 µg/m3). PM2.5 peaks in homes using wood fires occurred during morning and evening cooking times. Johnston et al., subsequently reported results of the chemical analyses of PM2.5 filters [6]. They identified several PM2.5 constituents, including aluminum, calcium, copper, iron, silicon, and titanium, above levels found to be associated with respiratory health effects in prior studies [11,12].
To date, we are not aware of any studies that have reported measures of other pollutants in brick workers’ homes, although the potential for those exposures exists. Likely exposures include carbon monoxide (CO), carbon dioxide (CO2), nitrogen dioxide (NO2), sulfur dioxide (SO2), and non-occupational respirable crystalline SiO2 dust. It is common among some brick kilns in the Kathmandu Valley to use “woods, recycled motor oils, coals, fuel oils, diesels, tires, trashes, and plastics for fuel” [13] (p. 185), which contributes to ambient levels of CO, CO2, NO2, and SO2 [13,14]. Brick worker housing is generally built using un-mortared brick walls with tin roofs, and relatively large openings between the bricks and other building materials. This loose construction allows easy infiltration of ambient air pollution into and out of homes [5]. Agro-residue burning and forest fires, automobile traffic, manufacturing (brick kilns), and cooking activities (kerosene, firewood, and LPG) are major sources of CO in the Kathmandu Valley [15,16,17]. Brick workers in Nepal live in homes with high occupant density, which may contribute to elevated levels of CO2 from exhaled breath [5]. NO2 is among the most common air pollutants and is primarily produced by man-made sources, including burning of fossil fuel [18,19]. SO2 results from the burning of coal and other fuels containing sulfur. SO2 can then dissolve in water vapor or interact with other gases to form acid, sulfates, or other respiratory particles [20]. SiO2 is the major component of most rocks and contains biologically active (respirable) particles measuring < 5 μm [21]. Considering the proximity of worker housing to their respective brick kilns, and the potential for dust to blow into brick worker housing through gaps in construction materials, the possibility exists for non-occupational, indoor exposure to SiO2 during non-working hours. Thus, our purpose in this study was to measure indoor CO, CO2, NO2, SO2, and respirable crystalline SiO2 (cristobalite, quartz, tridymite) in brick workers’ homes. Understanding these exposures may provide important knowledge related to respiratory and other diseases in this population of workers, and potential avenues to prevent future exposures.

2. Materials and Methods

2.1. Study Design

We selected brick worker homes for our cross-sectional study using convenience sampling in May 2018. We recruited four homes from each of four brick kilns for a total of 16 homes. All homes included in our study were located within an approximate 100 m radius of their respective brick kiln, and all kilns were located in Bhaktapur, Kathmandu Valley, Nepal. At each of the four brick kilns, we characterized homes as being either fire master or worker domiciles. We then recruited two fire master and two worker homes at each kiln. Fire master homes are typically located on the brick kiln, while worker (non-fire master) homes are typically located adjacent to the kiln (Figure 1), which we hypothesized would lead to different exposure profiles. We hypothesized fire masters’ homes would have higher indoor and outdoor air pollution levels than workers’ homes due to their proximity to brick kiln smoke. The Institutional Review Board (IRB) at Brigham Young University reviewed this study prior to our arrival in Nepal. The IRB determined the study did not include human subjects’ research according to U.S. Code of Federal Regulations Title 45, Part 46 [22].
We collected samples indoors and outdoors at each study home. The arithmetic mean (AM) sampling time was 6.67 h (standard deviation [SD]: 0.38 h). We placed instruments by clipping them to a light-weight cord suspended between two tripod stands so that they hung about 1.1–1.2 m from the ground, the height of an adult home occupant’s mouth/nose when crouching inside the home, which was required due to the low heights of the roofs. The methods used for these samples, and a questionnaire we administered to an adult resident of each home regarding characteristics of homes or samples that may be related to air pollution concentrations, were described previously [5].

2.2. Respirable Crystalline SiO2 Measurement

Respirable crystalline SiO2 samples were collected in accordance with U.S. National Institute for Occupational Safety and Health (NIOSH) Method 7500 [23]. All SiO2 samples were collected using SKC AirLite (SKC Inc., Eighty Four, PA, USA) sampling pumps. Pumps were calibrated to 2.5 L/min prior to being deployed. Pumps were pre- and post-calibrated with a DryCal® Defender 510 volumetric flow standard (Mesa Labs, Butler, NJ, USA). The sampling train consisted of tubing, a 37 mm styrene cassette housing a pre-weighed 5.0 μm PVC membrane filter, and an aluminum cyclone with a 4.0-μm cut-point (SKC Inc., Eighty Four, PA, USA). Pre- and post-air flow calibrations were conducted with the sampling train in-place. Gravimetric and X-ray diffraction (XRD) analyses for SiO2 were conducted at ALS Laboratories in Salt Lake City, UT, USA. The lower detection limit masses for cristobalite, quartz, and tridymite were five µg, five µg, and 30 µg, respectively.

2.3. CO and CO2 Measurement

We measured CO and CO2 levels using Drager Pac 7000 Personal Gas Detectors (SKC Inc., Eighty Four, PA, USA). Both the CO and CO2 monitors were pre-calibrated by SKC Inc. prior to sample collection (CO LDL concentration: 6 ppm; CO2 LDL concentration: 3000 ppm). Prior to each sampling day, we used the Pac 7000 software to ensure that the settings were correct and that the memory was clear on each device. We clipped a CO and CO2 device on the suspension string and followed the device manual for use (SKC Inc., Eighty Four, PA, USA). We set each device to measure in 10 s intervals. We had one additional CO and CO2 monitor saved for backup as needed. For post sampling, we connected each device to a computer through the Pac 7000 cartridge and then transferred and saved the data as Excel spreadsheets.

2.4. NO2 and SO2 Measurement

We assessed NO2 and SO2 levels using UMEX200 Passive Samplers (SKC Inc., Eighty Four, PA, USA). Each badge is fitted internally with a tape treated with triethanolamine (TEA) that absorbs nitrogen oxides (NOx) and sulfur oxides (SOx). Following the instructions from SKC Inc., we opened the aluminum pouch to remove the badge, clipped it onto the suspension string, and slid the sampler cover down to the “on” position. After the sampling period, we slid the cover up to the “off” position and immediately enclosed the sampler in the original aluminum pouch (SKC Inc., Eighty Four, PA, USA). We took a field blank for each day of sampling. We stored the samples in the aluminum pouches until we sent them for analysis at ALS Laboratories in Salt Lake City, Utah, USA. The LDL masses were 2.5 and 1.8 μg for NO2 and SO2, respectively.

2.5. Statistical Analyses

We used SAS version 9.4 (SAS Institute, Inc., Cary, NC, USA) for all data management and analyses. CO and CO2 measurements were recorded every 10 s, so we calculated the AM of measurements during the sampling period for each sample. If 100% of CO or CO2 measurements were above the LDL for a particular sample, then we calculated the AM for the sample using intercept only linear regression models. If less than 100% of CO or CO2 measurements were above the LDL for a particular sample, then we calculated the AM for the sample using intercept only Tobit regression models. If the AM for the sample was below the LDL, then we considered the entire sample to be below the LDL.
For categorical characteristics of homes or samples, we calculated frequencies and percentages. For continuous characteristics of homes or samples, we calculated the AM, SD, minimum, first quartile, median, third quartile, and maximum. For air pollutants, we calculated frequencies and percentages of samples that had measurements above and below LDLs. For air pollutants that had at least one measurement above LDLs, we calculated GMs and 95% confidence intervals (CI) for each air pollutant using separate intercept only Tobit regression models that used the natural logarithm of air pollution concentrations as dependent variables because no air pollutant had 100% of measurements above LDLs and distributions of air pollutants were right skewed. We calculated minimum and maximum air pollutant concentrations from samples that had measurements above LDLs.
We used separate simple (i.e., unadjusted) exact unconditional logistic regression models to calculate exact odds ratios (OR) and exact 95% CI for associations between characteristics of homes or samples and having air pollutant concentrations above LDLs if greater than 10%, but less than or equal to 30%, of samples had measurements above LDLs [24,25]. We used separate simple (i.e., unadjusted) Tobit regression models that used the natural logarithm of air pollution concentrations as dependent variables to calculate GM and 95% CI for associations between characteristics of homes or samples and air pollutant concentrations if greater than 30% of samples had measurements above LDLs [24,25]. If a characteristic of homes or samples that had more than two categories was significantly associated with air pollutant concentrations, then we used the Tukey–Kramer method to test for pairwise differences in air pollutant concentrations among the categories of the characteristic of homes or samples.
We repeated analyses of associations between characteristics of homes or samples and air pollutant concentrations or having air pollutant concentrations above LDLs using indoor air samples only. We used multivariable Tobit regression models that used the natural logarithm of air pollutant concentrations as dependent variables to estimate adjusted associations between characteristics of homes or samples and air pollutant concentrations when more than one characteristic of homes or samples was associated with air pollutant concentrations in simple (i.e., unadjusted) Tobit regression models.

3. Results

We collected 32 air pollution samples from 16 homes (i.e., from four homes each at four kilns (Table 1). We collected 16 of the samples at homes of fire masters and 16 at homes of workers. Similarly, we collected 16 of the samples inside homes and 16 outside homes. The AM size of house was 82.16 ft2 (7.64 m2), the median time lived in house was 5.50 months, the AM number of people who lived in house was 4.71, and the median occupant density was 62.50 residents/100 m2. We collected 36% of samples at homes that had 1–3 children 0–18 years-old who lived in the house and 31% of samples at homes that had 1–3 children under six years-old who lived in the house. We collected 60%, 67%, and 50% of samples at homes that used wood only as the primary fuel for cooking, electricity as the type of heating source in the home, and candle as the type of non-electric light source in the home, respectively. We collected 67% of samples at homes that had any smokers living in the home and 33% of these samples at homes that had 2–4 smokers living in the home who regularly smoked inside the home. We collected 25% of samples at homes that had 3–4 smokers living in the home.
All samples had air concentrations below LDLs for NO2, SiO2 (cristobalite), SiO2 (tridymite), and SO2 (Table 2). Only two (6%), eight (25%), and 19 (61%) samples had concentrations of CO, CO2, and SiO2 (quartz), respectively, above LDLs. GMs were 0.84 ppm, 1447.34 ppm, and 6.22 µg/m3 for CO, CO2, and SiO2 (quartz), respectively.
Using all indoor and outdoor air samples, no characteristic of homes or samples was significantly associated with having CO2 concentrations above the LDL (Table 3). A two month increase in how long lived in house was significantly (p = 0.01) associated with a nine percent (95% CI: 2%, 18%) increase in GM SiO2 (quartz) concentrations (Table 4). Samples at homes with other (lightbulb, line cable) or no type of heating source in the home had significantly (p = 0.0008) higher SiO2 (quartz) concentrations (GM: 10.15, 95% CI: 6.84, 15.07 µg/m3) than samples at homes with electricity (GM: 3.77, 95% CI: 2.48, 5.75 µg/m3). Samples at homes with no smokers living in the home had significantly (p = 0.03) higher SiO2 (quartz) concentrations (GM: 9.36, 95% CI: 5.78, 15.13 µg/m3) than samples at homes with smokers (GM: 4.75, 95% CI: 3.16, 7.14 µg/m3). How many smokers living in the home was significantly (p = 0.03) associated with SiO2 (quartz) concentrations. Tukey–Kramer pairwise comparisons indicated samples at homes with zero smokers living in the home had significantly (p = 0.01) higher SiO2 (quartz) concentrations (GM: 9.43, 95% CI: 6.04, 14.75 µg/m3) than samples at homes with 1–2 smokers (GM: 3.53, 95% CI: 1.91, 6.54 µg/m3). No other characteristic of homes or samples was significantly associated with SiO2 (quartz) concentrations.
Using indoor air samples only, the exact OR for the association between a two month increase in how long lived in house and having CO2 concentrations above the LDL was 0.05 (exact 95% CI: < 0.01, 1.00; exact p = 0.05; Supplementary Materials, Table S1). Samples at homes with other (lightbulb, line cable) or no type of heating source in the home had significantly (p = 0.04) higher SiO2 (quartz) concentrations (GM: 9.74, 95% CI: 5.70, 16.66 µg/m3) than samples at homes with electricity (GM: 4.64, 95% CI: 2.86, 7.53 µg/m3; Supplementary Materials, Table S2). No other characteristic of homes or samples was significantly associated with having CO2 concentrations above the LDL or SiO2 (quartz) concentrations indoors. However, the aforementioned associations between characteristics of homes or samples and SiO2 (quartz) concentrations using all indoor and outdoor air samples were generally in the same directions and of similar magnitudes using indoor air samples only.
When we mutually adjusted how long lived in house, type of heating source in the home, and any smokers living in the home for each other using all indoor and outdoor air samples, only type of heating source in the home remained significantly (p = 0.0002) associated with SiO2 (quartz) concentrations. Similarly, only type of heating source in the home remained significantly (p = 0.002) associated with SiO2 (quartz) concentrations when we mutually adjusted how long lived in house, type of heating source in the home, and how many smokers living in the home for each other using all indoor and outdoor air samples.

4. Discussion

In our study of gaseous air pollutants and respirable crystalline SiO2 concentrations inside and outside homes of workers at brick kilns in Bhaktapur, Kathmandu Valley, Nepal, we found concentrations of air pollutants to be low and usually undetectable. Most characteristics of homes or samples were not associated with CO2 or SiO2 (quartz) concentrations using all indoor and outdoor samples or indoor samples only. Type of heating source in the home was the characteristic of homes or samples that was most consistently associated with SiO2 (quartz) concentrations in various analyses and concentrations were higher at homes with other (lightbulb, line cable) or no type of heating source in the home compared to homes with electricity. An explanation for why other or no type of heating source was associated with respirable SiO2 in brick workers’ homes is elusive. One thought is that the respirable fraction of SiO2 has a long settling time. It is possible that brick workers with no heating source behave differently during cold morning hours than workers with a heating source. For instance, workers with no heating may use more blankets that emit dust particles, resuspending small SiO2 particles in the air. For particles < 2.5 µm, it takes 85 min to fall one m, and for particles < 1.0 µm, it takes 485 min to fall one m in indoor air with low air exchange rates [26]. It may be that workers with no heating suspend more dust before leaving their homes for work, which we picked up on the air monitors.
We are unaware of previous studies that measured concentrations of gaseous air pollutants and respirable crystalline SiO2 inside or outside homes of brick kiln workers. However, a study of occupational exposures conducted at 12 brick kilns in Patiala district, Punjab, India, reported mean area air concentrations of 2.02 µg/m3 for CO, 0.89 µg/m3 for CO2, 96 µg/m3 for NOx, and 91.76 µg/m3 for SOx [27]. Pangtey et al. conducted a study at 22 fixed chimney Bull’s trench brick kilns in Lucknow, India, and found mean area air concentrations of 3.44 ppm for CO, 0.23 ppm for NOx, and 0.35 ppm for SO2 [28]. A study conducted at three fixed chimney Bull’s trench brick kilns in Kasur district, Pakistan, used area samples to measure air pollution concentrations in two areas of the kiln: modulation and kiln [29]. Workers in the modulation area completed activities such as digging, wetting, mixing, and lifting clay and mud and molding and arranging bricks for drying, whereas workers in the kiln area completed activities such as carrying, loading, and arranging bricks, adding coal to the fire, and unloading and sorting fired bricks. Mean concentrations of NO2 and SO2 were 0.0591 ppm and zero ppm, respectively, in the modulation area and 0.07 ppm and 0.0652 ppm, respectively, in the kiln area. Sanjel et al. used personal breathing zone sampling to measure respirable crystalline SiO2 (quartz) among 46 workers at fixed chimney Bull’s trench brick kilns in the Kathmandu Valley, Nepal. The GM respirable crystalline SiO2 (quartz) concentrations among workers in five similar exposure groups were 92 µg/m3 for coal crushing/carrying preparation, 102 µg/m3 for fireman, 71 µg/m3 for green brick molding, 223 µg/m3 for green brick stacking/carrying, and 331 µg/m3 for red brick loading/carrying [4]. In our study, GM area air concentrations inside and outside homes of workers at four fixed chimney Bull’s trench brick kilns in Bhaktapur, Kathmandu Valley, Nepal, were 0.84 ppm for CO, 1447.34 ppm for CO2, and 6.22 µg/m3 for SiO2 (quartz), but NO2, SO2, SiO2 (cristobalite), and SiO2 (tridymite) concentrations were below LDLs. Considered together, these studies suggest air concentrations of CO, CO2, NO2/x, and SO2/x at fixed chimney Bull’s trench brick kilns and on-site worker housing in Asia are typically low, whereas concentrations of SiO2 (quartz) are typically high at brick kilns, but low at on-site worker housing.
CO2 is an essential byproduct of cellular metabolism with ambient levels generally about 380 ppm [30,31]. Combustion of fossil fuels such as coal, natural gas and oil are the primary human activities that emit CO2. The main sources of CO2 emissions in the United States include gasoline and diesel emissions, electricity, and fossil fuel combustion during various industrial processes [32]. In Nepal, fossil fuel and biofuel consumption are the main sources of CO2 emissions and brick kilns generate an estimated 11% of CO2 emissions [33]. In our study, individuals mainly used wood for cooking, electricity as a heating source in the home and candles as a type of non-electric light source. The latest OSHA standard for CO2 is 5000 ppm as an eight-hour time-weighted average (TWA) concentration [34]. Concentrations as low as 800 ppm can increase heart rate, blood pressure, and cardiac output and stimulate ventilation and other respiratory symptoms while concentrations from 1000–2500 ppm can lead to significantly reduced cognitive performance [30,31]. Unconsciousness or death can result from exposure to concentrations of 10% (100,000 ppm) or more [34]. There are multiple ways to prevent harmful CO2 exposure including alarms which monitor CO2 concentrations in the home. In addition, educational interventions can help inform individuals of the hazards of CO2 in the air and prevent dangerous situations.
The SiO2 exposure experienced by our study population is directly caused by the bricks in Nepal’s brick kilns [4]. Inhalation exposure to crystalline SiO2 is associated with significantly increased risks of developing acute and chronic silicosis, COPD, pulmonary tuberculosis, and rheumatoid arthritis [35]. Among these, the health effect of highest concern is silicosis because the effects of SiO2 on the lungs are irreversible and can lead to lung cancer [36]. There is evidence that workers’ cumulative SiO2 exposure is directly associated with lung cancer risk [37]. The World Health Organization’s International Agency for Research on Cancer has declared crystalline SiO2 to be a group 1 (definite) human lung carcinogen based its review of both animal and human SiO2 exposure studies [38]. A no-observed-adverse-effect level (NOAEL) for SiO2 has not been established due to workers developing silicosis even at the lowest estimated cumulative exposure ranges reported [36]. To protect against these adverse health outcomes, OSHA has developed a PEL of 50 µg/m3 over an eight-hour work period and an action level of 25 µg/m3 [39]. If measured SiO2 levels rise above the action level, then the use of wet methods (e.g., wet spray misting) have been shown to be low-cost, effective methods to decrease exposure [40]. If the use of wet methods is not practical or feasible, then it is recommended that particulate respirators with a high-efficiency filter be worn by those experiencing exposure [41].
CO2 and SiO2 (quartz) concentrations were not associated with most characteristics of homes or samples in our study. Notably, location of sample (indoor, outdoor) was not associated with having CO2 concentrations above the LDL and indoor GM SiO2 (quartz) concentrations were not significantly different from outdoor GM SiO2 (quartz) concentrations. As discussed previously [5], the homes of brick kiln workers we sampled for our study were made of un-mortared bricks that had gaps between the bricks and the walls and tin roofs. The doors were typically covered by natural fiber hangings and the floors were made of dirt. This construction likely resulted in free exchange of air and air pollution between the inside and outside of homes and suspension and resuspension of dust into the breathing zones of brick workers and their family members. In addition, dust containing SiO2 (quartz) could have blown into brick workers’ homes and led to non-occupational, indoor exposure to SiO2 (quartz) during non-working hours.
Only a few characteristics of homes or samples were associated with SiO2 (quartz) concentrations in our study. A possible explanation for the positive association between how long lived in house and SiO2 (quartz) concentrations may be take-home exposure (e.g., via contaminated worker clothing). We detected SiO2 (quartz) in 61% of air samples collected at homes of brick kiln workers. Although the low GM SiO2 (quartz) concentration we found may suggest take-home exposure to SiO2 (quartz) is a relatively minor problem in this population of workers and their families, take-home exposures could result in SiO2 (quartz) dust accumulating at the home over time. As mentioned previously, the SiO2 (quartz) could then be resuspended into the breathing zones of brick kiln workers and their family members, which could be confirmed by future studies. Reasons for associations between type of heating source in the home and whether and how many smokers were living in the home and SiO2 (quartz) concentrations are not apparent. However, only type of heating source in the home remained significantly associated with SiO2 (quartz) concentrations when we restricted to indoor samples only or when we mutually adjusted associations between these characteristics and SiO2 (quartz) concentrations for each other.
Our study had several strengths and limitations. Strengths included a novel research question because we think we were the first to study concentrations of gaseous air pollutants and respirable crystalline SiO2 at homes of brick kiln workers. We also collected air samples at homes of brick workers at four different brick kilns in different areas of Bhaktapur, Kathmandu Valley, Nepal. We used state-of-the-art air sampling equipment, measured multiple air pollutants inside and outside of homes, and collected information about several characteristics of homes or samples which may be associated with air pollution concentrations. Limitations included our use of a cross-sectional study design with sampling at one point in time, so our results may not generalize to air pollution concentrations over longer periods of time. In addition, we used a convenience sample, so our results may not generalize to homes of other brick workers at the brick kilns included in our study or elsewhere. We had a relatively small sample size (n = 32 air samples), although it was 60% larger than other studies of air pollution conducted among this population [6,7]. We also sampled during non-prime cooking hours, which may explain why we found concentrations of air pollutants to be low and usually undetectable. In addition, the LDL for CO2 was relatively high. Finally, we used area rather than personal air samples, so our estimates of air pollution concentrations may not reflect those in study participants’ personal breathing zones. Future studies should address these limitations by measuring air pollution concentrations over longer periods of time (e.g., days to weeks or even months), including a larger, representative sample of homes or workers, sampling during prime cooking hours during the morning and evening, sampling during the colder season, using instruments that can measure air pollution, particularly gaseous pollutants, at lower concentrations, and using personal breathing zone sampling to estimate personal rather than area exposures.

5. Conclusions

In conclusion, concentrations of gaseous air pollutants and respirable crystalline SiO2 inside and outside homes of workers at brick kilns in Bhaktapur, Kathmandu Valley, Nepal, were low and usually undetectable. However, these results need to be confirmed by future studies that sample during prime cooking hours. Concentrations of CO2 and SiO2 (quartz) were not associated with the majority of characteristics of homes or samples. Take-home exposures to SiO2 (quartz) could lead to higher SiO2 (quartz) air concentrations at brick kiln workers’ homes over time. Interventions should focus on administrative controls such as providing brick kiln workers with clean clothing to use for non-work times and encouraging regular bathing, changing from work to non-work clothes at the end of work shifts, washing of work clothes, and cleaning of homes.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/ijerph191912431/s1, Table S1. Associations between characteristics and having CO2 air concentrations measured inside homes above the LDL at brick kilns in Bhaktapur, Kathmandu Valley, Nepal, May 2018; Table S2. Associations between characteristics and SiO2 (quartz) air concentrations measured inside homes at brick kilns in Bhaktapur, Kathmandu Valley, Nepal, May 2018.

Author Contributions

Conceptualization, S.M.T. and J.D.J.; methodology, J.D.B., S.M.T. and J.D.J.; validation, J.D.B., S.M.T. and J.D.J.; formal analysis, J.D.B.; investigation, S.M.T. and J.D.J.; resources, J.D.B., S.M.T. and J.D.J.; data curation, J.D.B.; writing—original draft preparation, J.D.B., S.M.T., A.O., J.E.T., S.W. and J.D.J.; writing—review and editing, J.D.B., S.M.T., A.O., J.E.T., S.W. and J.D.J.; visualization, J.D.B.; supervision, J.D.B., S.M.T. and J.D.J.; project administration, J.D.B., S.M.T. and J.D.J. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The IRB at Brigham Young University reviewed this study prior to our arrival in Nepal. The IRB determined the study did not include human subjects’ research according to U.S. Code of Federal Regulations Title 45, Part 46 [22].

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available upon request from the corresponding author.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. World Health Organization. WHO Global Air Quality Guidelines. Particulate Matter (PM2.5 and PM10), Ozone, Nitrogen Dioxide, Sulfur Dioxide and Carbon Monoxide; World Health Organization: Geneva, Switzerland, 2021; Available online: https://apps.who.int/iris/bitstream/handle/10665/345329/9789240034228-eng.pdf?sequence=1&isAllowed=y (accessed on 28 July 2022).
  2. Saud, B.; Paudel, G. The threat of ambient air pollution in Kathmandu, Nepal. J. Environ. Public Health 2018, 2018, 1504591. [Google Scholar] [CrossRef] [PubMed]
  3. Shakya, K.M.; Rupakheti, M.; Shahi, A.; Maskey, R.; Pradhan, B.; Panday, A.; Puppala, S.P.; Lawrence, M.; Peltier, R.E. Near-road sampling of PM2.5, BC, and fine-particle chemical components in Kathmandu Valley. Nepal. Atmos. Chem. Phys. 2017, 17, 6503–6516. [Google Scholar] [CrossRef]
  4. Sanjel, S.; Khanal, S.N.; Thygerson, S.M.; Carter, W.; Johnston, J.D.; Joshi, S.K. Exposure to respirable silica among clay brick workers in Kathmandu valley, Nepal. Arch. Environ. Occup. Health 2018, 73, 347–350. [Google Scholar] [CrossRef] [PubMed]
  5. Thygerson, S.M.; Beard, J.D.; House, M.J.; Smith, R.L.; Burbidge, H.C.; Andrus, K.N.; Weber, F.X.; Chartier, R.; Johnston, J.D. Air-quality assessment of on-site brick-kiln worker housing in Bhaktapur, Nepal: Chemical speciation of indoor and outdoor PM2.5 pollution. Int. J. Environ. Res. Public Health 2019, 16, 4114. [Google Scholar] [CrossRef]
  6. Johnston, J.D.; Beard, J.D.; Montague, E.J.; Sanjel, S.; Lu, J.H.; McBride, H.; Weber, F.X.; Chartier, R.T. Chemical composition of PM2.5 in wood fire and LPG cookstove homes of Nepali brick workers. Atmosphere 2021, 12, 911. [Google Scholar] [CrossRef]
  7. Johnston, J.D.; Hawks, M.E.; Johnston, H.B.; Johnson, L.A.; Beard, J.D. Comparison of liquefied petroleum gas cookstoves and wood cooking fires on PM2.5 trends in brick workers’ homes in Nepal. Int. J. Environ. Res. Public Health 2020, 17, 5681. [Google Scholar] [CrossRef]
  8. Sanjel, S.; Khanal, S.N.; Thygerson, S.M.; Carter, W.S.; Johnston, J.D.; Joshi, S.K. Respiratory symptoms and illnesses related to the concentration of airborne particulate matter among brick kiln workers in Kathmandu valley, Nepal. Ann. Occup. Environ. Med. 2017, 29, 9. [Google Scholar] [CrossRef]
  9. Eisner, M.D.; Anthonisen, N.; Coultas, D.; Kuenzli, N.; Perez-Padilla, R.; Postma, D.; Romieu, I.; Silverman, E.K.; Balmes, J.R. Environmental Occupational Health Assembly Committee on Nonsmoking COPD. An official American Thoracic Society public policy statement: Novel risk factors and the global burden of chronic obstructive pulmonary disease. Am. J. Respir. Crit. Care Med. 2010, 182, 693–718. [Google Scholar] [CrossRef]
  10. Li, J.; Qin, C.; Lv, J.; Guo, Y.; Bian, Z.; Zhou, W.; Hu, J.; Zhang, Y.; Chen, J.; Cao, W.; et al. Solid fuel use and incident COPD in Chinese adults: Findings from the China Kadoorie Biobank. Environ. Health Perspect. 2019, 127, 57008. [Google Scholar] [CrossRef]
  11. Bell, M.L.; Ebisu, K.; Leaderer, B.P.; Gent, J.F.; Lee, H.J.; Koutrakis, P.; Wang, Y.; Dominici, F.; Peng, R.D. Associations of PM2.5 constituents and sources with hospital admissions: Analysis of four counties in Connecticut and Massachusetts (USA) for persons ≥ 65 years of age. Environ. Health Perspect. 2014, 122, 138–144. [Google Scholar] [CrossRef] [Green Version]
  12. Ostro, B.; Roth, L.; Malig, B.; Marty, M. The effects of fine particle components on respiratory hospital admissions in children. Environ. Health Perspect. 2009, 117, 475–480. [Google Scholar] [CrossRef] [PubMed]
  13. Pariyar, S.K.; Das, T.; Ferdous, T. Environment and health impact for brick kilns in Kathmandu valley. Int. J. Sci. Technol. Res. 2013, 2, 184–187. [Google Scholar]
  14. Joshi, S.K.; Dudani, I. Environmental health effects of brick kilns in Kathmandu valley. Kathmandu Univ. Med. J. 2008, 6, 3–11. [Google Scholar]
  15. Dhakal, S. Implications of transportation policies on energy and environment in Kathmandu Valley, Nepal. Energy Policy 2003, 31, 1493–1507. [Google Scholar] [CrossRef]
  16. Mahata, K.S.; Rupakheti, M.; Panday, A.K.; Bhardwaj, P.; Naja, M.; Singh, A.; Mues, A.; Cristofanelli, P.; Pudasainee, D.; Bonasoni, P.; et al. Observation and analysis of spatiotemporal characteristics of surface ozone and carbon monoxide at multiple sites in the Kathmandu Valley, Nepal. Atmos. Chem. Phys. 2018, 18, 14113–14132. [Google Scholar] [CrossRef]
  17. Shrestha, S.R.; Oanh, N.T.K.; Xu, Q.; Rupakheti, M.; Lawrence, M.G. Analysis of the vehicle fleet in the Kathmandu Valley for estimation of environment and climate co-benefits of technology intrusions. Atmos. Environ. 2013, 81, 579–590. [Google Scholar] [CrossRef]
  18. Salonen, H.; Salthammer, T.; Morawska, L. Human exposure to NO2 in school and office indoor environments. Environ. Int. 2019, 130, 104887. [Google Scholar] [CrossRef]
  19. Zhao, S.; Liu, S.; Sun, Y.; Liu, Y.; Beazley, R.; Hou, X. Assessing NO2-related health effects by non-linear and linear methods on a national level. Sci. Total Environ. 2020, 744, 140909. [Google Scholar] [CrossRef]
  20. Chen, T.M.; Gokhale, J.; Shofer, S.; Kuschner, W.G. Outdoor air pollution: Nitrogen dioxide, sulfur dioxide, and carbon monoxide health effects. Am. J. Med. Sci. 2007, 333, 249–256. [Google Scholar] [CrossRef]
  21. Hoy, R.F.; Chambers, D.C. Silica-related diseases in the modern world. Allergy 2020, 75, 2805–2817. [Google Scholar] [CrossRef]
  22. U.S. Code of Federal Regulations Title 45, Part 46.104. Available online: https://www.ecfr.gov/current/title-45/subtitle-A/subchapter-A/part-46/subpart-A/section-46.104 (accessed on 26 July 2022).
  23. National Institute for Occupational Safety and Health. Method 7500 Silica, Crystalline, by XRD (Filter Redeposition). In NIOSH Manual of Analytical Methods, 4th ed.; Schlecht, P.C., O’Connor, P.F., Eds.; Issue 4, DHHS (NIOSH) Publication No. 2003-154; U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health: Cincinnati, OH, USA, 2003. Available online: https://www.cdc.gov/niosh/docs/2003-154/pdfs/7500.pdf (accessed on 26 July 2022).
  24. Beard, J.D.; Erdely, A.; Dahm, M.M.; de Perio, M.A.; Birch, M.E.; Evans, D.E.; Fernback, J.E.; Eye, T.; Kodali, V.; Mercer, R.R.; et al. Carbon nanotube and nanofiber exposure and sputum and blood biomarkers of early effect among U.S. workers. Environ. Int. 2018, 116, 214–228. [Google Scholar] [CrossRef] [PubMed]
  25. Lubin, J.H.; Colt, J.S.; Camann, D.; Davis, S.; Cerhan, J.R.; Severson, R.K.; Bernstein, L.; Hartge, P. Epidemiologic evaluation of measurement data in the presence of detection limits. Environ. Health Perspect. 2004, 112, 1691–1696. [Google Scholar] [CrossRef] [PubMed]
  26. Gao, N.P.; Niu, J.L. Modeling particle dispersion and deposition in indoor environments. Atmos. Environ. 2007, 41, 3862–3876. [Google Scholar] [CrossRef] [PubMed]
  27. Tandon, S.; Gupta, S.; Singh, S.; Kumar, A. Respiratory abnormalities among occupationally exposed, non-smoking brick kiln workers from Punjab, India. Int. J. Occup. Environ. Med. 2017, 8, 166–173. [Google Scholar] [CrossRef] [PubMed]
  28. Pangtey, B.S.; Kumar, S.; Bihari, V.; Mathur, N.; Rastogi, S.K.; Srivastava, A.K. An environmental profile of brick kilns in Lucknow. J. Environ. Sci. Eng. 2004, 46, 239–244. [Google Scholar] [PubMed]
  29. Raza, A.; Ali, Z. Impact of air pollution generated by brick kilns on the pulmonary health of workers. J. Health Pollut. 2021, 11, 210906. [Google Scholar] [PubMed]
  30. Satish, U.; Mendell, M.J.; Shekhar, K.; Hotchi, T.; Sullivan, D.; Streufert, S.; Fisk, W.J. Is CO2 an indoor pollutant? Direct effects of low-to-moderate CO2 concentrations on human decision-making performance. Environ. Health Perspect. 2012, 120, 1671–1677. [Google Scholar] [CrossRef]
  31. Shriram, S.; Ramamurthy, K.; Ramakrishnan, S. Effect of occupant-induced indoor CO2 concentration and bioeffluents on human physiology using a spirometric test. Build. Environ. 2019, 149, 58–67. [Google Scholar] [CrossRef]
  32. U.S. Environmental Protection Agency. Overview of Greenhouse Gases. Available online: https://www.epa.gov/ghgemissions/overview-greenhouse-gases (accessed on 26 July 2022).
  33. Sadavarte, P.; Rupakheti, M.; Bhave, P.; Shakya, K.; Lawrence, M. Nepal emission inventory–Part I: Technologies and combustion sources (NEEMI-Tech) for 2001–2016. Atmos. Chem. Phys. 2019, 19, 12953–12973. [Google Scholar] [CrossRef]
  34. Occupational Safety and Health Administration. Potential Carbon Dioxide (CO2) Asphyxiation Hazard When Filling Stationary Low Pressure CO2 Supply Systems; OSHA HIB 06-05-1996; U.S. Department of Labor, Occupational Health and Safety Administration: Washington, DC, USA, 1996. Available online: https://www.osha.gov/publications/hib19960605 (accessed on 26 July 2022).
  35. Calvert, G.M.; Rice, F.L.; Boiano, J.M.; Sheehy, J.W.; Sanderson, W.T. Occupational silica exposure and risk of various diseases: An analysis using death certificates from 27 states of the United States. Occup. Environ. Med. 2003, 60, 122–129. [Google Scholar] [CrossRef]
  36. Agency for Toxic Substances and Disease Registry. Toxicological Profile for Silica; U.S. Department of Health and Human Services, Agency for Toxic Substances and Disease Registry: Atlanta, GA, USA, 2019. Available online: https://www.atsdr.cdc.gov/ToxProfiles/tp211.pdf (accessed on 26 July 2022).
  37. Sato, T.; Shimosato, T.; Klinman, D.M. Silicosis and lung cancer: Current perspectives. Lung Cancer Targets Ther. 2018, 9, 91–101. [Google Scholar] [CrossRef] [PubMed]
  38. International Agency for Research on Cancer. Arsenic, Metals, Fibres, and Dusts. In IARC Monographs on the Evaluation of Carcinogenic Risks to Humans; International Agency for Research on Cancer: Lyon, France, 2012; Volume 100C, Available online: https://publications.iarc.fr/120 (accessed on 26 July 2022).
  39. Occupational Safety and Health Administration. Silica, Crystalline. Available online: https://www.osha.gov/silica-crystalline (accessed on 26 July 2022).
  40. Gottesfeld, P.; Tirima, S.; Anka, S.M.; Fotso, A.; Nota, M.M. Reducing lead and silica dust exposures in small-scale mining in northern Nigeria. Ann. Work Expo. Health 2019, 63, 1–8. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  41. National Institute for Occupational Safety and Health. NIOSH Policy Statement. Respiratory Protection Recommendations for Airborne Exposures to Crystalline Silica; DHHS (NIOSH) Publication No. 2008–140; U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health: Cincinnati, OH, USA, 2008. Available online: https://www.cdc.gov/niosh/docs/2008-140/pdfs/2008-140.pdf (accessed on 26 July 2022).
Figure 1. (A) Home of fire master on the brick kiln (for fixed chimney Bull’s trench brick kilns), (B) homes of brick workers adjacent to the brick kiln, and (C) brick kiln chimney in Bhaktapur, Kathmandu Valley, Nepal, May 2018.
Figure 1. (A) Home of fire master on the brick kiln (for fixed chimney Bull’s trench brick kilns), (B) homes of brick workers adjacent to the brick kiln, and (C) brick kiln chimney in Bhaktapur, Kathmandu Valley, Nepal, May 2018.
Ijerph 19 12431 g001
Table 1. Characteristics of air pollution samples collected inside and outside homes at brick kilns in Bhaktapur, Kathmandu Valley, Nepal, May 2018.
Table 1. Characteristics of air pollution samples collected inside and outside homes at brick kilns in Bhaktapur, Kathmandu Valley, Nepal, May 2018.
CharacteristicSamples, nMissing, nAMSDMinQ1MedianQ3Max
Total32
Size of house, feet228482.1636.3920.0052.0084.00112.00150.00
Size of house, m22847.643.351.904.807.8010.4013.90
How long lived in house, months2848.827.894.005.005.507.0030.00
How many people live in house2484.712.192.003.004.006.009.00
Occupant density, residents/100 m2221073.4849.8919.2343.1762.5090.91210.53
Abbreviations: AM, arithmetic mean; Max, maximum; Min, minimum; Q1, first quartile; Q3, third quartile; SD, standard deviation.
Table 2. LDLs and summary statistics for air pollutants measured inside and outside homes at brick kilns in Bhaktapur, Kathmandu Valley, Nepal, May 2018.
Table 2. LDLs and summary statistics for air pollutants measured inside and outside homes at brick kilns in Bhaktapur, Kathmandu Valley, Nepal, May 2018.
Total Samples
Above LDL
Air PollutantLDL Mass (μg)LDL Concentration RangeMissing, nBelow LDL, n (%)n (%)GM a95% CI aMin bMax b
CO, ppmNA6.00 30 (94)2 (6)0.840.05, 14.009.9112.99
CO2, ppmNA3000.00 24 (75)8 (25)1447.34651.18, 3216.953799.3212,975.99
NO2, μg/m32.50325.47, 404.79 32 (100)0 (0)NANANANA
SiO2 (cristobalite), μg/m35.004.55, 6.04131 (100)0 (0)NANANANA
SiO2 (quartz), μg/m35.004.55, 6.04112 (39)19 (61)6.224.56, 8.485.1943.28
SiO2 (tridymite), μg/m330.0027.29, 36.22131 (100)0 (0)NANANANA
SO2, μg/m31.80266.71, 331.71 32 (100)0 (0)NANANANA
Abbreviations: CO, carbon monoxide; CO2, carbon dioxide; CI, confidence interval; GM, geometric mean; LDL, lower detection limit; Max, maximum; Min, minimum; NA, not applicable; NO2, nitrogen dioxide; SiO2, crystalline silica; SO2, sulfur dioxide. a Estimated using intercept only Tobit regression models of the natural logarithm transformed values. b Calculated using only samples that had values above LDLs.
Table 3. Associations between characteristics and having CO2 air concentrations measured inside and outside homes above the LDL at brick kilns in Bhaktapur, Kathmandu Valley, Nepal, May 2018.
Table 3. Associations between characteristics and having CO2 air concentrations measured inside and outside homes above the LDL at brick kilns in Bhaktapur, Kathmandu Valley, Nepal, May 2018.
CO2, ppm
CharacteristicBelow LDL, n (%)Above LDL, n (%)Exact OR aExact 95% CI aExact p-Value a
Kiln number
 16 (25)2 (25)1.00Reference
 26 (25)2 (25)1.000.05, 18.27
 36 (25)2 (25)1.000.05, 18.27
 46 (25)2 (25)1.000.05, 18.271.00
Type of home
 Worker13 (54)3 (38)1.00Reference
 Fire master11 (46)5 (63)1.930.29, 15.340.69
Location of sample
 Indoor11 (46)5 (63)1.00Reference
 Outdoor13 (54)3 (38)0.520.07, 3.390.69
Size of house, 50 feet2 1.000.30, 3.331.00
 Missing31
Size of house, m2 1.000.77, 1.301.00
 Missing31
How long lived in house, two months 1.090.88, 1.320.43
 Missing31
How many people live in house 1.020.67, 1.540.93
 Missing71
Occupant density, 10 residents/100 m2 1.030.84, 1.220.78
 Missing82
How many children 0–18 years-old live in house
 012 (57)6 (86)1.00Reference
 1–39 (43)1 (14)0.23<0.01, 2.490.37
 Missing31
How many children under 6 years-old live in house
 012 (63)6 (86)1.00Reference
 1–37 (37)1 (14)0.300.01, 3.350.55
 Missing51
Primary fuel used for cooking
 Gas only6 (26)0 (0)0.37 b0.00, 2.38
 Wood only13 (57)5 (71)1.00Reference
 Other c4 (17)2 (29)1.290.09, 12.960.49
 Missing11
Type of heating source in the home
 Electricity12 (63)4 (80)1.00Reference
 Other d or none7 (37)1 (20)0.440.01, 5.790.89
 Missing53
Type of non-electric light source in the home
 Candle11 (52)3 (43)0.560.04, 9.11
 Generator6 (29)2 (29)0.690.03, 13.30
 Other e or none4 (19)2 (29)1.00Reference1.00
 Missing31
Any smokers living in the home
 No8 (35)2 (29)1.00Reference
 Yes15 (65)5 (71)1.320.16, 16.871.00
 Missing11
How many smokers living in the home
 08 (42)2 (40)1.00Reference
 1–26 (32)2 (40)1.310.07, 23.23
 3–45 (26)1 (20)0.810.01, 19.751.00
 Missing53
How many smokers living in the home regularly smoke inside the home
 0–110 (71)2 (50)1.00Reference
 2–44 (29)2 (50)2.360.13, 44.120.81
 Missing104
Abbreviations: CO2, carbon dioxide; CI, confidence interval; LDL, lower detection limit; OR, odds ratio. a Estimated using simple (i.e., unadjusted) exact unconditional logistic regression models. b Median unbiased estimate. c Includes coal and wood, gas and wood. d Includes lightbulb, line cable. e Includes candle and torch, fuel.
Table 4. Associations between characteristics and SiO2 (quartz) air concentrations measured inside homes at brick kilns in Bhaktapur, Kathmandu Valley, Nepal, May 2018.
Table 4. Associations between characteristics and SiO2 (quartz) air concentrations measured inside homes at brick kilns in Bhaktapur, Kathmandu Valley, Nepal, May 2018.
SiO2 (Quartz), μg/m3
CharacteristicBelow LDL, n (%)Above LDL, n (%)GM a95% CI ap-Value a
Kiln number
 10 (0)8 (42)9.265.62, 15.27
 22 (15)6 (32)6.693.97, 11.27
 34 (31)4 (21)7.274.09, 12.90
 47 (54)1 (5)2.671.20, 5.930.08
Type of home
 Worker8 (62)8 (42)4.983.23, 7.66
 Fire master5 (38)11 (58)7.755.25, 11.430.13
Location of sample
 Indoor6 (46)10 (53)6.003.94, 9.13
 Outdoor7 (54)9 (47)6.484.19, 10.000.80
Size of house, 50 feet2 1.08 b0.64, 1.83 b0.78
 Missing04
Size of house, m2 1.01 b0.91, 1.14 b0.80
 Missing04
How long lived in house, two months 1.09 b1.02, 1.18 b0.01
 Missing13
How many people live in house 1.10 b0.91, 1.32 b0.32
 Missing26
Occupant density, 10 residents/100 m2 0.97 b0.87, 1.08 b0.55
 Missing28
How many children 0–18 years-old live in house
 09 (75)9 (56)5.643.59, 8.86
 1–33 (25)7 (44)6.563.81, 11.310.67
 Missing13
How many children under 6 years-old live in house
 09 (75)9 (64)5.633.57, 8.90
 1–33 (25)5 (36)5.322.84, 9.960.88
 Missing15
Primary fuel used for cooking
 Gas only4 (31)2 (12)3.881.73, 8.69
 Wood only8 (62)10 (59)6.394.16, 9.80
 Other c1 (8)5 (29)7.253.72, 14.120.46
 Missing02
Type of heating source in the home
 Electricity12 (100)4 (33)3.772.48, 5.75
 Other d or none0 (0)8 (67)10.156.84, 15.070.0008
 Missing17
Type of non-electric light source in the home
 Candle8 (67)6 (38)5.373.20, 8.99
 Generator0 (0)8 (50)9.265.27, 16.28
 Other e or none4 (33)2 (13)4.041.79, 9.090.20
 Missing13
Any smokers living in the home
 No2 (15)8 (47)9.365.78, 15.13
 Yes11 (85)9 (53)4.753.16, 7.140.03
 Missing02
How many smokers living in the home
 02 (22)8 (53)9.436.04, 14.75
 1–25 (56)3 (20)3.531.91, 6.54
 3–42 (22)4 (27)7.524.15, 13.610.03 f
 Missing44
How many smokers living in the home regularly smoke inside the home
 0–18 (80)4 (50)4.142.27, 7.55
 2–42 (20)4 (50)6.113.17, 11.790.37
 Missing311
Abbreviations: CI, confidence interval; GM, geometric mean; LDL, lower detection limit; SiO2, crystalline silica. a Estimated using simple (i.e., unadjusted) Tobit regression models of the natural logarithm transformed values. b Exponentiated regression coefficient and 95% CI (i.e., GM SiO2 [quartz] concentration ratio for a specified change in the independent variable or exp(β)—1 = percent change in GM SiO2 [quartz] concentration for a specified change in the independent variable). c Includes coal and wood, gas and wood. d Includes lightbulb, line cable. e Includes candle and torch, fuel. f Adjusting for multiple comparisons using the Tukey–Kramer method, tests of pairwise differences among categories of how many smokers living in the home had the following p-values: 0 vs. 1–2: 0.01, 0 vs. 3–4: 0.55, and 1–2 vs. 3–4: 0.08.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Beard, J.D.; Thygerson, S.M.; Olivares, A.; Tadje, J.E.; Willis, S.; Johnston, J.D. Gaseous Air Pollutants and Respirable Crystalline Silica Inside and Outside Homes at Brick Kilns in Bhaktapur, Kathmandu Valley, Nepal. Int. J. Environ. Res. Public Health 2022, 19, 12431. https://doi.org/10.3390/ijerph191912431

AMA Style

Beard JD, Thygerson SM, Olivares A, Tadje JE, Willis S, Johnston JD. Gaseous Air Pollutants and Respirable Crystalline Silica Inside and Outside Homes at Brick Kilns in Bhaktapur, Kathmandu Valley, Nepal. International Journal of Environmental Research and Public Health. 2022; 19(19):12431. https://doi.org/10.3390/ijerph191912431

Chicago/Turabian Style

Beard, John D., Steven M. Thygerson, Alisandra Olivares, Jaxson E. Tadje, Selah Willis, and James D. Johnston. 2022. "Gaseous Air Pollutants and Respirable Crystalline Silica Inside and Outside Homes at Brick Kilns in Bhaktapur, Kathmandu Valley, Nepal" International Journal of Environmental Research and Public Health 19, no. 19: 12431. https://doi.org/10.3390/ijerph191912431

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.