Next Article in Journal
Updated Meta-Analysis of Randomized Controlled Trials Comparing External Fixation to Intramedullary Nailing in the Treatment of Open Tibial Fractures
Previous Article in Journal
Evaluation of Therapeutic Capability of Emustil Drops against Tear Film Complications under Dry Environmental Conditions in Healthy Individuals
Previous Article in Special Issue
Intraoperative Hypotension Prediction—A Proactive Perioperative Hemodynamic Management—A Literature Review
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Continuous Blood Pressure Monitoring in Patients Having Surgery: A Narrative Review

1
Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, 20251 Hamburg, Germany
2
Outcomes Research Consortium, Cleveland, OH 44195, USA
*
Author to whom correspondence should be addressed.
Medicina 2023, 59(7), 1299; https://doi.org/10.3390/medicina59071299
Submission received: 18 April 2023 / Revised: 11 June 2023 / Accepted: 10 July 2023 / Published: 14 July 2023
(This article belongs to the Special Issue Evolving Concepts in Hemodynamic Management)

Abstract

:
Hypotension can occur before, during, and after surgery and is associated with postoperative complications. Anesthesiologists should thus avoid profound and prolonged hypotension. A crucial part of avoiding hypotension is accurate and tight blood pressure monitoring. In this narrative review, we briefly describe methods for continuous blood pressure monitoring, discuss current evidence for continuous blood pressure monitoring in patients having surgery to reduce perioperative hypotension, and expand on future directions and innovations in this field. In summary, continuous blood pressure monitoring with arterial catheters or noninvasive sensors enables clinicians to detect and treat hypotension immediately. Furthermore, advanced hemodynamic monitoring technologies and artificial intelligence—in combination with continuous blood pressure monitoring—may help clinicians identify underlying causes of hypotension or even predict hypotension before it occurs.

1. Introduction

In patients having surgery under general anesthesia, profound and prolonged hypotension is associated with organ injury—specifically, acute kidney and myocardial injury [1,2]—and postoperative mortality [3,4,5,6]. Hypotension can occur after anesthetic induction before surgical incision (postinduction hypotension), during surgery (intraoperative hypotension), and after surgery (postoperative hypotension) [7,8,9]. Associations with organ injury have been shown for postinduction hypotension [8], intraoperative hypotension [1,2,3,4,5], and postoperative hypotension [9,10,11,12].
While the association between perioperative hypotension and organ injury is well established, optimal blood pressure targets for individual patients remain controversial [13,14,15]. Pending results from robust clinical trials on targeted blood pressure management [16] (ClinicalTrials.gov identifier: NCT04884802), anesthesiologists should avoid profound and prolonged hypotension and maintain mean arterial pressure (MAP) above 65 mmHg during surgery [17]—and presumably somewhat higher postoperatively [6,18].
A crucial part of avoiding hypotension is accurate and tight blood pressure monitoring. Improving blood pressure monitoring to help avoid perioperative hypotension is thus a matter of ongoing research. Continuous blood pressure monitoring with arterial catheters or noninvasive sensors provides blood pressure in real-time and may enable clinicians to detect and treat hypotension immediately. Furthermore, advanced hemodynamic monitoring technologies and predictive monitoring may help clinicians identify underlying causes of hypotension or even predict hypotension before it occurs [19,20].
In this article, we briefly describe methods for continuous blood pressure monitoring, discuss current evidence for continuous blood pressure monitoring in patients having surgery to reduce perioperative hypotension, and expand on future directions and innovations in this field.

2. Methods for Continuous Blood Pressure Monitoring

The clinical reference method (i.e., gold standard) to continuously measure blood pressure is intraarterial blood pressure monitoring with an arterial catheter [21]. However, intraarterial blood pressure monitoring requires the cannulation of an artery, which can very rarely cause serious complications such as ischemia or major bleeding [22].
Noninvasive finger sensors allow blood pressure to be monitored continuously without arterial cannulation. Noninvasive blood pressure monitoring with finger sensors is based on the vascular unloading technique [23,24]. The underlying measurement principle is based on the theory that a force exerted by a body can be determined by measuring a counterforce – assuming a steady physical coupling [25]. Finger sensors contain an inflatable finger cuff and integrated infrared photodiodes and light detectors. The infrared system measures the blood volume in the finger arteries which changes periodically throughout the cardiac cycle. A control system adjusts the cuff pressure high-frequently to keep the blood volume in the finger arteries constant. Based on the cuff pressure adjustments, a continuous blood pressure waveform can be reconstructed and analyzed to obtain absolute blood pressure values. Validation studies investigating the accuracy of finger sensor-derived blood pressures compared to intraarterial blood pressures revealed heterogeneous results [26]. On the one hand, several studies demonstrated interchangeability between finger sensor and intraarterial blood pressure monitoring [26,27,28,29,30] and—even more importantly—superiority of finger sensor blood pressure monitoring compared to oscillometric blood pressure monitoring [31]. For example, in patients having bariatric surgery, the agreement between finger sensor and intraarterial blood pressures was better than the agreement between oscillometric and intraarterial blood pressures [31]. On the other hand, there are also studies suggesting that finger sensor and intraarterial blood pressure monitoring are not interchangeable [32,33,34,35]. Finger sensor blood pressure monitoring may thus be used instead of intermittent oscillometric blood pressure monitoring rather than instead of intraarterial blood pressure monitoring. Finger sensor blood pressure monitoring becomes unreliable in patients with impaired finger perfusion—such as patients with circulatory shock or high-dose vasopressor therapy [28,36]—who usually have intraarterial monitoring anyway.

3. Continuous Blood Pressure Monitoring during Anesthetic Induction

Postinduction hypotension, i.e., hypotension between the start of anesthetic induction and surgical incision, is common [7,37,38] and associated with acute kidney injury [8]. Postinduction hypotension accounts for about one-third of all perioperative hypotension [8] and is mainly determined by anesthetic management [39]—specifically vasodilation by anesthetic drugs [38]. Postinduction hypotension is “scheduled hypotension” that usually rapidly occurs after the administration of anesthetic drugs.
Despite the obvious cause of postinduction hypotension, blood pressure is usually monitored only intermittently using upper-arm cuff oscillometry during anesthetic induction even if intraarterial blood pressure monitoring with an arterial catheter is planned for intraoperative blood pressure monitoring. In a recent survey, almost two-thirds of European anesthesiologists stated that they would insert arterial catheters usually only after the administration of anesthetic induction agents, i.e., when the patient is already under general anesthesia—instead of inserting arterial catheters before anesthetic induction [40]. It is reasonable to assume that intermittent blood pressure monitoring easily misses hypotension and that continuous—compared to intermittent—blood pressure monitoring may reduce postinduction hypotension.
A single-center randomized trial including 242 noncardiac surgery patients indeed confirmed that continuous intraarterial compared to intermittent oscillometric blood pressure monitoring reduces hypotension during anesthetic induction [41]. All patients had a clinical indication for intraarterial blood pressure monitoring during surgery. In all patients, the arterial catheter was inserted before anesthetic induction. Patients were then assigned to continuous intraarterial or intermittent oscillometric blood pressure monitoring (with blinded continuous intraarterial blood pressure monitoring) during the first 15 min of anesthetic induction. The median (25th percentile, 75th percentile) area under a MAP of 65 mmHg was 46 (7, 111) mmHg x min in patients assigned to intermittent oscillometric blood pressure monitoring and 15 (2, 36) mmHg x min in patients assigned to continuous intraarterial blood pressure monitoring. Patients assigned to intermittent oscillometric blood pressure monitoring spend a median duration of 5.4 (2.1, 9.5) min below a MAP of 65 mmHg—compared to 2.6 (0.7, 5.0) min in patients assigned to continuous intraarterial blood pressure monitoring [41]. In this trial, continuous intraarterial blood pressure monitoring thus not only reduced the duration but also the severity of hypotension [41]. In patients for whom continuous intraarterial blood pressure monitoring is planned, clinicians should thus consider inserting arterial catheters before, rather than after, anesthetic induction.
Most patients having surgery do not have a clinical indication for intraarterial blood pressure monitoring with an arterial catheter [42]. In these patients, who are monitored with intermittent oscillometry in today’s clinical practice, finger sensors could be used for continuous blood pressure monitoring. The decision whether to use arterial catheters or finger sensors depends on patient- and surgery-related risk factors [6].
Whether finger sensor blood pressure monitoring helps reduce postinduction hypotension is a subject of current research. In a single-center randomized trial with 242 noncardiac surgery patients, patients were assigned to continuous finger sensor blood pressure monitoring or intermittent oscillometric blood pressure monitoring (with blinded continuous finger sensor blood pressure monitoring) [43]. Continuous finger sensor—compared to intermittent oscillometric—blood pressure monitoring, reduced the severity and duration of hypotension during the first 15 min of anesthetic induction. Based on the results of this trial, clinicians should consider continuous finger sensor blood pressure monitoring rather than intermittent oscillometric blood pressure monitoring during anesthetic induction.
These trials suggest that continuous blood pressure monitoring during anesthetic induction reduces hypotension compared to intermittent blood pressure monitoring. To reduce postinduction hypotension, blood pressure should thus be monitored continuously during anesthetic induction, either with an arterial catheter or with a finger sensor. However, the extent of hypotension reduction on postoperative complications is unclear and needs to be investigated in large randomized trials.

4. Continuous Blood Pressure Monitoring during Surgery

Intraoperative hypotension, i.e., hypotension during surgery, is common [44] and associated with acute kidney injury, acute myocardial injury, and mortality [1,45,46]. Several trials investigated the effect of continuous blood pressure monitoring on intraoperative hypotension [43,47,48,49].
In a randomized trial, 306 patients having noncardiac surgery were assigned either to continuous intraarterial blood pressure monitoring or intermittent oscillometric blood pressure monitoring [50]. Hypotension was quantified either based on continuous intraarterial or intermittent oscillometric blood pressure monitoring. The median area under a MAP of 65 mmHg was 24 (1, 121) mmHg x min in patients assigned to continuous intraarterial blood pressure monitoring and 10 (0, 57) mmHg x min in patients assigned to intermittent oscillometric blood pressure monitoring. This trial shows that continuous intraarterial blood pressure monitoring detects more than twice as much hypotension as intermittent oscillometric blood pressure monitoring [50]. These results may be in part explainable by the intermittent measurement character and overestimation of low blood pressures by oscillometry [51].
A trial including 316 moderate-to-high-risk patients investigated whether continuous finger sensor blood pressure monitoring reduces intraoperative hypotension compared to intermittent oscillometric blood pressure monitoring (with blinded finger sensor blood pressure monitoring) [49]. Hypotension was quantified using the time-weighted average MAP < 65 mmHg. The median time-weighted average MAP < 65 mmHg was 0.05 (0.00, 0.22) mmHg in patients assigned to continuous finger sensor blood pressure monitoring and 0.11 (0.00, 0.54) mmHg in patients assigned to intermittent oscillometric blood pressure monitoring.
These results are in line with a trial in 160 patients having orthopedic surgery under general anesthesia in which patients were assigned to continuous finger sensor blood pressure monitoring or to intermittent oscillometric blood pressure monitoring [48]. Hypotension was defined as a single MAP measurement < 60 mmHg. Hypotension occurred less frequently in patients assigned to continuous finger sensor blood pressure monitoring than in patients assigned to intermittent oscillometric blood pressure monitoring (51 hypotensive events versus 19 hypotensive events).
In another randomized trial, 242 noncardiac surgery patients were assigned to continuous finger sensor blood pressure monitoring or to intermittent oscillometric blood pressure monitoring (with blinded continuous finger sensor blood pressure monitoring) [43]. The severity and duration of hypotension during surgery quantified as the time-weighted average MAP < 65 mmHg was lower in patients assigned to continuous finger sensor blood pressure monitoring compared to patients assigned to intermittent oscillometric blood pressure monitoring [43].

5. Continuous Blood Pressure Monitoring after Surgery

Postoperative hypotension, i.e., hypotension within the first days after surgery, is common [52] and associated with acute kidney injury, myocardial injury, and mortality [9,10,11]. A substudy of the POISE-2 trial with more than 9000 patients showed that patients with postoperative hypotension within the first four postoperative days have almost three times higher odds of 30-day myocardial infarction and death than patients without postoperative hypotension [9]. Nearly one in five postoperative patients suffers from hypotension (defined as a MAP < 65 mmHg for at least 15 consecutive minutes) during the first two postoperative days [52]. On normal wards, blood pressure is usually only spot-checked every 4–8 h. Thus, postoperative hypotension often remains undetected and untreated [52,53,54]. For example, hypotensive episodes defined as a MAP < 70 mmHg for at least 15 consecutive minutes are not detected on normal wards in approximately 80% of all cases [53].
To detect postoperative hypotension, close or even continuous blood pressure monitoring would be needed [52,53]. As severe postoperative complications are often preceded by hypotension several minutes or hours earlier [55], timely recognition of hypotension may help improve patient outcomes.
In intensive care units, blood pressure is routinely measured continuously using arterial catheters. However, on normal wards, blood pressure is measured by nurses only every few hours. Continuous monitoring of blood pressure—and other vital signs—is an intriguing new concept that has the potential to revolutionize patient care [56,57,58,59]. Continuous blood pressure monitors on normal wards need to be small, noninvasive, and untethered. Additionally, they should not interfere with patients’ mobility or sleep. Different technologies for continuous blood pressure monitoring on normal wards are available, including the vascular unloading technique, pulse-wave transit time, and pulse decomposition [60,61,62]. Finger sensors can be used for continuous blood pressure monitoring on normal wards, but current systems still are not wireless and not well tolerated by patients [54]. Miniaturized wireless finger sensor systems are currently being developed [63]. Blood pressure sensors such as chest patches or wrist sensors are often photoplethysmography-based and use the pulse-wave transit time method to estimate blood pressure [61,64,65,66]. Several variables, including pulse rate and peripheral oxygen saturation, can be accurately monitored with wearable sensors. However, studies investigating the measurement performance of wearable sensors to measure blood pressure revealed contradicting results. Many of the currently available devices do not yet pass criteria of international measurement performance standards [67,68].

6. Will Artificial Intelligence Change Continuous Blood Pressure Monitoring?

Artificial intelligence may substantially change current concepts of continuous blood pressure monitoring. Current blood pressure management is mainly reactive, with hypotension being treated only when it has already occurred [69]. Artificial intelligence can be used to analyze the blood pressure waveform and predict hypotension (Figure 1). Predictive monitoring may help avoid hypotension [69]. For example, the hypotension prediction index software (HPI-software) (Edwards Lifesciences, Irvine, CA, USA) analyzes the blood pressure waveform and provides a unitless number ranging from 0 to 100 that is an indicator for the likelihood of a patient developing hypotension [20]. The HPI-software was developed using a machine-learning algorithm considering waveform features [20]. HPI-software monitoring can be used on blood pressure waveforms from arterial catheters or finger sensors [70]. Trials investigating whether HPI-software monitoring reduces intraoperative hypotension compared to blood pressure management without HPI-software monitoring revealed contradictory results [71,72]. Robust trials are needed to investigate the effect of HPI-software monitoring on postoperative complications.
Artificial intelligence can also be used to identify distinct underlying causes of hypotension (Figure 1). In a recent study in patients having major abdominal surgery, an unsupervised machine-learning algorithm was used to identify endotypes of intraoperative hypotension based on essential hemodynamic variables, including stroke volume index, heart rate, cardiac index, systemic vascular resistance index, and pulse pressure variation [19]. Six different endotypes were identified: myocardial depression, bradycardia, vasodilation with cardiac index increase, vasodilation without cardiac index increase, hypovolemia, and mixed type [19]. Identifying and considering these different endotypes may help clinicians to treat hypotension causally and may help improve postoperative outcomes.

7. Conclusions

In patients having surgery under general anesthesia, profound and prolonged hypotension is associated with organ injury—specifically, acute kidney and myocardial injury—and postoperative mortality. Hypotension can occur after anesthetic induction before surgical incision (postinduction hypotension), during surgery (intraoperative hypotension), and after surgery (postoperative hypotension). Anesthesiologists should avoid profound and prolonged hypotension and maintain MAP above 65 mmHg during surgery—and presumably somewhat higher postoperatively. A crucial part of avoiding hypotension is accurate and tight blood pressure monitoring. The clinical reference method to continuously measure blood pressure is intraarterial blood pressure monitoring with an arterial catheter. Noninvasive finger sensors allow blood pressure to be monitored continuously without arterial cannulation. Trials suggest that continuous blood pressure monitoring during anesthetic induction and during surgery reduces hypotension compared to intermittent blood pressure monitoring. To reduce postinduction and intraoperative hypotension, blood pressure should thus be monitored continuously—either with an arterial catheter or with a finger sensor. However, the effect of hypotension reduction on postoperative complications is unclear and needs to be investigated in large randomized trials. Postoperative hypotension, i.e., hypotension within the first days after surgery, is common—and mainly missed by current spot-check measurements by nurses. Continuous monitoring of blood pressure is an intriguing new concept that has the potential to revolutionize patient care. Different technologies for continuous blood pressure monitoring on normal wards have been suggested, but none is established in routine care. Artificial intelligence can be used to analyze the continuous blood pressure waveform and predict hypotension, and identify distinct endotypes of hypotension.

Author Contributions

All authors take responsibility for the intellectual content of this article, and all authors contributed to its writing. All authors have read and agreed to the published version of the manuscript.

Funding

Support was provided solely from institutional and/or departmental sources.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

A.B. and G.G. have no conflict of interest to declare. K.K. is a consultant for and has received honoraria for giving lectures from Edwards Lifesciences Inc. (Irvine, CA, USA). K.K. is a consultant for Vygon (Aachen, Germany). BS is a consultant for and has received institutional restricted research grants and honoraria for giving lectures from Edwards Lifesciences (Irvine, CA, USA). BS is a consultant for Philips North America (Cambridge, MA, USA) and has received honoraria for giving lectures from Philips Medizin Systeme (Böblingen, Germany). BS is a consultant for and has received institutional restricted research grants and honoraria for giving lectures from Baxter (Deerfield, IL, USA). BS is a consultant for and has received institutional restricted research grants and honoraria for giving lectures from GE Healthcare (Chicago, IL, USA). BS has received institutional restricted research grants and honoraria for giving lectures from CNSystems Medizintechnik (Graz, Austria). BS is a consultant for Maquet Critical Care (Solna, Sweden). BS has received honoraria for giving lectures from Getinge (Gothenburg, Sweden). BS is a consultant for and has received institutional restricted research grants and honoraria for giving lectures from Pulsion Medical Systems (Feldkirchen, Germany). BS is a consultant for and has received honoraria for giving lectures from Vygon (Aachen, Germany). BS is a consultant for and has received institutional restricted research grants from Retia Medical (Valhalla, NY, USA). BS has received institutional restricted research grants from Osypka Medical (Berlin, Germany). BS was a consultant for and has received institutional restricted research grants from Tensys Medical (San Diego, CA, USA).

Abbreviations

HPI-softwarehypotension prediction index software
MAPmean arterial pressure

References

  1. Walsh, M.; Devereaux, P.J.; Garg, A.X.; Kurz, A.; Turan, A.; Rodseth, R.N.; Cywinski, J.; Thabane, L.; Sessler, D.I. Relationship between intraoperative mean arterial pressure and clinical outcomes after noncardiac surgery: Toward an empirical definition of hypotension. Anesthesiology 2013, 119, 507–515. [Google Scholar] [CrossRef] [PubMed]
  2. Ahuja, S.; Mascha, E.J.; Yang, D.; Maheshwari, K.; Cohen, B.; Khanna, A.K.; Ruetzler, K.; Turan, A.; Sessler, D.I. Associations of Intraoperative Radial Arterial Systolic, Diastolic, Mean, and Pulse Pressures with Myocardial and Acute Kidney Injury after Noncardiac Surgery: A Retrospective Cohort Analysis. Anesthesiology 2020, 132, 291–306. [Google Scholar] [CrossRef] [PubMed]
  3. Gregory, A.; Stapelfeldt, W.H.; Khanna, A.K.; Smischney, N.J.; Boero, I.J.; Chen, Q.; Stevens, M.; Shaw, A.D. Intraoperative Hypotension Is Associated With Adverse Clinical Outcomes After Noncardiac Surgery. Anesth. Analg. 2021, 132, 1654–1665. [Google Scholar] [CrossRef] [PubMed]
  4. Wesselink, E.M.; Kappen, T.H.; Torn, H.M.; Slooter, A.J.C.; van Klei, W.A. Intraoperative hypotension and the risk of postoperative adverse outcomes: A systematic review. Br. J. Anaesth. 2018, 121, 706–721. [Google Scholar] [CrossRef] [Green Version]
  5. Wijnberge, M.; Schenk, J.; Bulle, E.; Vlaar, A.P.; Maheshwari, K.; Hollmann, M.W.; Binnekade, J.M.; Geerts, B.F.; Veelo, D.P. Association of intraoperative hypotension with postoperative morbidity and mortality: Systematic review and meta-analysis. BJS Open 2021, 5, zraa018. [Google Scholar] [CrossRef]
  6. Saugel, B.; Sessler, D.I. Perioperative Blood Pressure Management. Anesthesiology 2021, 134, 250–261. [Google Scholar] [CrossRef]
  7. Suedfeld, S.; Brechnitz, S.; Wagner, J.Y.; Reese, P.C.; Pinnschmidt, H.O.; Reuter, D.A.; Saugel, B. Post-induction hypotension and early intraoperative hypotension associated with general anaesthesia. Br. J. Anaesth. 2017, 119, 57–64. [Google Scholar] [CrossRef] [Green Version]
  8. Maheshwari, K.; Turan, A.; Mao, G.; Yang, D.; Niazi, A.K.; Agarwal, D.; Sessler, D.I.; Kurz, A. The association of hypotension during non-cardiac surgery, before and after skin incision, with postoperative acute kidney injury: A retrospective cohort analysis. Anaesthesia 2018, 73, 1223–1228. [Google Scholar] [CrossRef] [Green Version]
  9. Sessler, D.I.; Meyhoff, C.S.; Zimmerman, N.M.; Mao, G.; Leslie, K.; Vasquez, S.M.; Balaji, P.; Alvarez-Garcia, J.; Cavalcanti, A.B.; Parlow, J.L.; et al. Period-dependent Associations between Hypotension during and for Four Days after Noncardiac Surgery and a Composite of Myocardial Infarction and Death: A Substudy of the POISE-2 Trial. Anesthesiology 2018, 128, 317–327. [Google Scholar] [CrossRef]
  10. Liem, V.G.B.; Hoeks, S.E.; Mol, K.; Potters, J.W.; Grune, F.; Stolker, R.J.; van Lier, F. Postoperative Hypotension after Noncardiac Surgery and the Association with Myocardial Injury. Anesthesiology 2020, 133, 510–522. [Google Scholar] [CrossRef]
  11. Khanna, A.K.; Maheshwari, K.; Mao, G.; Liu, L.; Perez-Protto, S.E.; Chodavarapu, P.; Schacham, Y.N.; Sessler, D.I. Association Between Mean Arterial Pressure and Acute Kidney Injury and a Composite of Myocardial Injury and Mortality in Postoperative Critically Ill Patients: A Retrospective Cohort Analysis. Crit. Care Med. 2019, 47, 910–917. [Google Scholar] [CrossRef]
  12. van Lier, F.; Wesdorp, F.; Liem, V.G.B.; Potters, J.W.; Grune, F.; Boersma, H.; Stolker, R.J.; Hoeks, S.E. Association between postoperative mean arterial blood pressure and myocardial injury after noncardiac surgery. Br. J. Anaesth. 2018, 120, 77–83. [Google Scholar] [CrossRef] [Green Version]
  13. Futier, E.; Lefrant, J.Y.; Guinot, P.G.; Godet, T.; Lorne, E.; Cuvillon, P.; Bertran, S.; Leone, M.; Pastene, B.; Piriou, V.; et al. Effect of Individualized vs. Standard Blood Pressure Management Strategies on Postoperative Organ Dysfunction Among High-Risk Patients Undergoing Major Surgery: A Randomized Clinical Trial. JAMA 2017, 318, 1346–1357. [Google Scholar] [CrossRef]
  14. Hu, A.M.; Qiu, Y.; Zhang, P.; Zhao, R.; Li, S.T.; Zhang, Y.X.; Zheng, Z.H.; Hu, B.L.; Yang, Y.L.; Zhang, Z.J. Higher versus lower mean arterial pressure target management in older patients having non-cardiothoracic surgery: A prospective randomized controlled trial. J. Clin. Anesth. 2021, 69, 110150. [Google Scholar] [CrossRef]
  15. Wanner, P.M.; Wulff, D.U.; Djurdjevic, M.; Korte, W.; Schnider, T.W.; Filipovic, M. Targeting Higher Intraoperative Blood Pressures Does Not Reduce Adverse Cardiovascular Events Following Noncardiac Surgery. J. Am. Coll. Cardiol. 2021, 78, 1753–1764. [Google Scholar] [CrossRef]
  16. Bergholz, A.; Meidert, A.S.; Flick, M.; Krause, L.; Vettorazzi, E.; Zapf, A.; Brunkhorst, F.M.; Meybohm, P.; Zacharowski, K.; Zarbock, A.; et al. Effect of personalized perioperative blood pressure management on postoperative complications and mortality in high-risk patients having major abdominal surgery: Protocol for a multicenter randomized trial (IMPROVE-multi). Trials 2022, 23, 946. [Google Scholar] [CrossRef]
  17. Sessler, D.I.; Bloomstone, J.A.; Aronson, S.; Berry, C.; Gan, T.J.; Kellum, J.A.; Plumb, J.; Mythen, M.G.; Grocott, M.P.W.; Edwards, M.R.; et al. Perioperative Quality Initiative consensus statement on intraoperative blood pressure, risk and outcomes for elective surgery. Br. J. Anaesth. 2019, 122, 563–574. [Google Scholar] [CrossRef] [Green Version]
  18. McEvoy, M.D.; Gupta, R.; Koepke, E.J.; Feldheiser, A.; Michard, F.; Levett, D.; Thacker, J.K.M.; Hamilton, M.; Grocott, M.P.W.; Mythen, M.G.; et al. Perioperative Quality Initiative consensus statement on postoperative blood pressure, risk and outcomes for elective surgery. Br. J. Anaesth. 2019, 122, 575–586. [Google Scholar] [CrossRef]
  19. Kouz, K.; Brockmann, L.; Timmermann, L.M.; Bergholz, A.; Flick, M.; Maheshwari, K.; Sessler, D.I.; Krause, L.; Saugel, B. Endotypes of intraoperative hypotension during major abdominal surgery: A retrospective machine learning analysis of an observational cohort study. Br. J. Anaesth. 2023, 130, 253–261. [Google Scholar] [CrossRef]
  20. Hatib, F.; Jian, Z.; Buddi, S.; Lee, C.; Settels, J.; Sibert, K.; Rinehart, J.; Cannesson, M. Machine-learning Algorithm to Predict Hypotension Based on High-fidelity Arterial Pressure Waveform Analysis. Anesthesiology 2018, 129, 663–674. [Google Scholar] [CrossRef]
  21. Saugel, B.; Kouz, K.; Meidert, A.S.; Schulte-Uentrop, L.; Romagnoli, S. How to measure blood pressure using an arterial catheter: A systematic 5-step approach. Crit. Care 2020, 24, 172. [Google Scholar] [CrossRef] [Green Version]
  22. Scheer, B.; Perel, A.; Pfeiffer, U.J. Clinical review: Complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit. Care 2002, 6, 199–204. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  23. Peňáz, J. Patentova Listina. CISLO 1969, 133, 205. [Google Scholar]
  24. Peňáz, J.; Voigt, A.; Teichmann, W. Contribution to the continuous indirect blood pressure measuremen. Z. Gesamte Inn. Med. 1976, 31, 1030–1033. [Google Scholar] [PubMed]
  25. Parati, G.; Ongaro, G.; Bilo, G.; Glavina, F.; Castiglioni, P.; Di Rienzo, M.; Mancia, G. Non-invasive beat-to-beat blood pressure monitoring: New developments. Blood Press. Monit. 2003, 8, 31–36. [Google Scholar] [CrossRef]
  26. Saugel, B.; Hoppe, P.; Nicklas, J.Y.; Kouz, K.; Korner, A.; Hempel, J.C.; Vos, J.J.; Schon, G.; Scheeren, T.W.L. Continuous noninvasive pulse wave analysis using finger cuff technologies for arterial blood pressure and cardiac output monitoring in perioperative and intensive care medicine: A systematic review and meta-analysis. Br. J. Anaesth. 2020, 125, 25–37. [Google Scholar] [CrossRef]
  27. de Wilde, R.B.; de Wit, F.; Geerts, B.F.; van Vliet, A.L.; Aarts, L.P.; Vuyk, J.; Jansen, J.R. Non-invasive continuous arterial pressure and pulse pressure variation measured with Nexfin(®) in patients following major upper abdominal surgery: A comparative study. Anaesthesia 2016, 71, 788–797. [Google Scholar] [CrossRef] [Green Version]
  28. Martina, J.R.; Westerhof, B.E.; van Goudoever, J.; de Beaumont, E.M.; Truijen, J.; Kim, Y.S.; Immink, R.V.; Jobsis, D.A.; Hollmann, M.W.; Lahpor, J.R.; et al. Noninvasive continuous arterial blood pressure monitoring with Nexfin®. Anesthesiology 2012, 116, 1092–1103. [Google Scholar] [CrossRef] [Green Version]
  29. Ilies, C.; Bauer, M.; Berg, P.; Rosenberg, J.; Hedderich, J.; Bein, B.; Hinz, J.; Hanss, R. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br. J. Anaesth. 2012, 108, 202–210. [Google Scholar] [CrossRef] [Green Version]
  30. Ameloot, K.; Van De Vijver, K.; Van Regenmortel, N.; De Laet, I.; Schoonheydt, K.; Dits, H.; Broch, O.; Bein, B.; Malbrain, M.L. Validation study of Nexfin® continuous non-invasive blood pressure monitoring in critically ill adult patients. Minerva Anestesiol. 2014, 80, 1294–1301. [Google Scholar]
  31. Schumann, R.; Meidert, A.S.; Bonney, I.; Koutentis, C.; Wesselink, W.; Kouz, K.; Saugel, B. Intraoperative Blood Pressure Monitoring in Obese Patients. Anesthesiology 2021, 134, 179–188. [Google Scholar] [CrossRef]
  32. Jeleazcov, C.; Krajinovic, L.; Münster, T.; Birkholz, T.; Fried, R.; Schüttler, J.; Fechner, J. Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: Assessment during general anaesthesia. Br. J. Anaesth. 2010, 105, 264–272. [Google Scholar] [CrossRef] [Green Version]
  33. Broch, O.; Bein, B.; Gruenewald, M.; Carstens, A.; Illies, C.; Schöneich, F.; Steinfath, M.; Renner, J. A comparison of continuous non-invasive arterial pressure with invasive radial and femoral pressure in patients undergoing cardiac surgery. Minerva Anestesiol. 2013, 79, 248–256. [Google Scholar]
  34. Balzer, F.; Habicher, M.; Sander, M.; Sterr, J.; Scholz, S.; Feldheiser, A.; Müller, M.; Perka, C.; Treskatsch, S. Comparison of the non-invasive Nexfin® monitor with conventional methods for the measurement of arterial blood pressure in moderate risk orthopaedic surgery patients. J. Int. Med. Res. 2016, 44, 832–843. [Google Scholar] [CrossRef] [Green Version]
  35. Sakai, Y.; Yasuo, M.T.; Oyama, T.; Murakami, C.; Kakuta, N.; Tanaka, K. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy. J. Med. Investig. 2018, 65, 69–73. [Google Scholar] [CrossRef] [Green Version]
  36. Monnet, X.; Dres, M.; Ferre, A.; Le Teuff, G.; Jozwiak, M.; Bleibtreu, A.; Le Deley, M.C.; Chemla, D.; Richard, C.; Teboul, J.L. Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: Comparison with four other dynamic indices. Br. J. Anaesth. 2012, 109, 330–338. [Google Scholar] [CrossRef] [Green Version]
  37. Yoshimura, M.; Shiramoto, H.; Koga, M.; Morimoto, Y. Preoperative echocardiography predictive analytics for postinduction hypotension prediction. PLoS ONE 2022, 17, e0278140. [Google Scholar] [CrossRef]
  38. Saugel, B.; Bebert, E.J.; Briesenick, L.; Hoppe, P.; Greiwe, G.; Yang, D.; Ma, C.; Mascha, E.J.; Sessler, D.I.; Rogge, D.E. Mechanisms contributing to hypotension after anesthetic induction with sufentanil, propofol, and rocuronium: A prospective observational study. J. Clin. Monit. Comput. 2022, 36, 341–347. [Google Scholar] [CrossRef]
  39. Reich, D.L.; Hossain, S.; Krol, M.; Baez, B.; Patel, P.; Bernstein, A.; Bodian, C.A. Predictors of hypotension after induction of general anesthesia. Anesth. Analg. 2005, 101, 622–628. [Google Scholar] [CrossRef]
  40. Flick, M.; Joosten, A.; Scheeren, T.W.L.; Duranteau, J.; Saugel, B. Haemodynamic monitoring and management in patients having noncardiac surgery. Eur. J. Anaesthesiol. Intensive Care 2023, 2, e0017. [Google Scholar] [CrossRef]
  41. Kouz, K.; Wegge, M.; Flick, M.; Bergholz, A.; Moll-Khosrawi, P.; Nitzschke, R.; Trepte, C.J.C.; Krause, L.; Sessler, D.I.; Zollner, C.; et al. Continuous intra-arterial versus intermittent oscillometric arterial pressure monitoring and hypotension during induction of anaesthesia: The AWAKE randomised trial. Br. J. Anaesth. 2022, 129, 478–486. [Google Scholar] [CrossRef] [PubMed]
  42. Maguire, S.; Rinehart, J.; Vakharia, S.; Cannesson, M. Technical communication: Respiratory variation in pulse pressure and plethysmographic waveforms: Intraoperative applicability in a North American academic center. Anesth. Analg. 2011, 112, 94–96. [Google Scholar] [CrossRef] [PubMed]
  43. Kouz, K.; Weidemann, F.; Naebian, A.; Lohr, A.; Bergholz, A.; Thomsen, K.K.; Krause, L.; Petzoldt, M.; Moll-Khosrawi, P.; Sessler, D.I.; et al. Continuous finger-cuff versus intermittent oscillometric arterial pressure monitoring and hypotension during induction of anesthesia and non-cardiac surgery: The DETECT randomized trial. Anesthesiology 2023, in press. [CrossRef]
  44. Shah, N.J.; Mentz, G.; Kheterpal, S. The incidence of intraoperative hypotension in moderate to high risk patients undergoing non-cardiac surgery: A retrospective multicenter observational analysis. J. Clin. Anesth. 2020, 66, 109961. [Google Scholar] [CrossRef] [PubMed]
  45. Salmasi, V.; Maheshwari, K.; Yang, D.; Mascha, E.J.; Singh, A.; Sessler, D.I.; Kurz, A. Relationship between Intraoperative Hypotension, Defined by Either Reduction from Baseline or Absolute Thresholds, and Acute Kidney and Myocardial Injury after Noncardiac Surgery: A Retrospective Cohort Analysis. Anesthesiology 2017, 126, 47–65. [Google Scholar] [CrossRef]
  46. Stapelfeldt, W.H.; Yuan, H.; Dryden, J.K.; Strehl, K.E.; Cywinski, J.B.; Ehrenfeld, J.M.; Bromley, P. The SLUScore: A Novel Method for Detecting Hazardous Hypotension in Adult Patients Undergoing Noncardiac Surgical Procedures. Anesth. Analg. 2017, 124, 1135–1152. [Google Scholar] [CrossRef] [Green Version]
  47. Benes, J.; Simanova, A.; Tovarnicka, T.; Sevcikova, S.; Kletecka, J.; Zatloukal, J.; Pradl, R.; Chytra, I.; Kasal, E. Continuous non-invasive monitoring improves blood pressure stability in upright position: Randomized controlled trial. J. Clin. Monit. Comput. 2015, 29, 11–17. [Google Scholar] [CrossRef]
  48. Meidert, A.S.; Nold, J.S.; Hornung, R.; Paulus, A.C.; Zwissler, B.; Czerner, S. The impact of continuous non-invasive arterial blood pressure monitoring on blood pressure stability during general anaesthesia in orthopaedic patients: A randomised trial. Eur. J. Anaesthesiol. 2017, 34, 716–722. [Google Scholar] [CrossRef]
  49. Maheshwari, K.; Khanna, S.; Bajracharya, G.R.; Makarova, N.; Riter, Q.; Raza, S.; Cywinski, J.B.; Argalious, M.; Kurz, A.; Sessler, D.I. A Randomized Trial of Continuous Noninvasive Blood Pressure Monitoring During Noncardiac Surgery. Anesth. Analg. 2018, 127, 424–431. [Google Scholar] [CrossRef]
  50. Naylor, A.J.; Sessler, D.I.; Maheshwari, K.; Khanna, A.K.; Yang, D.; Mascha, E.J.; Suleiman, I.; Reville, E.M.; Cote, D.; Hutcherson, M.T.; et al. Arterial Catheters for Early Detection and Treatment of Hypotension During Major Noncardiac Surgery: A Randomized Trial. Anesth. Analg. 2020, 131, 1540–1550. [Google Scholar] [CrossRef]
  51. Wax, D.B.; Lin, H.M.; Leibowitz, A.B. Invasive and concomitant noninvasive intraoperative blood pressure monitoring: Observed differences in measurements and associated therapeutic interventions. Anesthesiology 2011, 115, 973–978. [Google Scholar] [CrossRef]
  52. Turan, A.; Chang, C.; Cohen, B.; Saasouh, W.; Essber, H.; Yang, D.; Ma, C.; Hovsepyan, K.; Khanna, A.K.; Vitale, J.; et al. Incidence, Severity, and Detection of Blood Pressure Perturbations after Abdominal Surgery: A Prospective Blinded Observational Study. Anesthesiology 2019, 130, 550–559. [Google Scholar] [CrossRef]
  53. Saab, R.; Wu, B.P.; Rivas, E.; Chiu, A.; Lozovoskiy, S.; Ma, C.; Yang, D.; Turan, A.; Sessler, D.I. Failure to detect ward hypoxaemia and hypotension: Contributions of insufficient assessment frequency and patient arousal during nursing assessments. Br. J. Anaesth. 2021, 127, 760–768. [Google Scholar] [CrossRef]
  54. King, C.E.; Kermode, A.; Saxena, G.; Carvelli, P.; Edwards, M.; Creagh-Brown, B.C. Postoperative continuous non-invasive cardiac output monitoring on the ward: A feasibility study. J. Clin. Monit. Comput. 2021, 35, 1349–1356. [Google Scholar] [CrossRef]
  55. Kause, J.; Smith, G.; Prytherch, D.; Parr, M.; Flabouris, A.; Hillman, K.; Intensive Care Society (UK) & Australian; New Zealand Intensive Care Society Clinical Trials Group. A comparison of antecedents to cardiac arrests, deaths and emergency intensive care admissions in Australia and New Zealand, and the United Kingdom—The ACADEMIA study. Resuscitation 2004, 62, 275–282. [Google Scholar] [CrossRef]
  56. Khanna, A.K.; Hoppe, P.; Saugel, B. Automated continuous noninvasive ward monitoring: Future directions and challenges. Crit. Care 2019, 23, 194. [Google Scholar] [CrossRef] [Green Version]
  57. Sessler, D.I.; Saugel, B. Beyond ‘failure to rescue’: The time has come for continuous ward monitoring. Br. J. Anaesth. 2019, 122, 304–306. [Google Scholar] [CrossRef] [Green Version]
  58. Saugel, B.; Hoppe, P.; Khanna, A.K. Automated Continuous Noninvasive Ward Monitoring: Validation of Measurement Systems Is the Real Challenge. Anesthesiology 2020, 132, 407–410. [Google Scholar] [CrossRef]
  59. Flick, M.; Saugel, B. Continuous ward monitoring: The selection, monitoring, alarms, response, treatment (SMART) road map. Br. J. Anaesth. 2021, 127, 675–677. [Google Scholar] [CrossRef]
  60. Michard, F.; Sessler, D.I.; Saugel, B. Non-invasive arterial pressure monitoring revisited. Intensive Care Med. 2018, 44, 2213–2215. [Google Scholar] [CrossRef]
  61. Michard, F.; Scheeren, T.W.L.; Saugel, B. A glimpse into the future of postoperative arterial blood pressure monitoring. Br. J. Anaesth. 2020, 125, 113–115. [Google Scholar] [CrossRef] [PubMed]
  62. Arakawa, T. Recent Research and Developing Trends of Wearable Sensors for Detecting Blood Pressure. Sensors 2018, 18, 2772. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  63. Fortin, J.; Rogge, D.E.; Fellner, C.; Flotzinger, D.; Grond, J.; Lerche, K.; Saugel, B. A novel art of continuous noninvasive blood pressure measurement. Nat. Commun. 2021, 12, 1387. [Google Scholar] [CrossRef]
  64. Kim, S.H.; Song, J.G.; Park, J.H.; Kim, J.W.; Park, Y.S.; Hwang, G.S. Beat-to-beat tracking of systolic blood pressure using noninvasive pulse transit time during anesthesia induction in hypertensive patients. Anesth. Analg. 2013, 116, 94–100. [Google Scholar] [CrossRef] [PubMed]
  65. Kachel, E.; Constantini, K.; Nachman, D.; Carasso, S.; Littman, R.; Eisenkraft, A.; Gepner, Y. A Pilot Study of Blood Pressure Monitoring After Cardiac Surgery Using a Wearable, Non-invasive Sensor. Front. Med. 2021, 8, 693926. [Google Scholar] [CrossRef]
  66. Finnegan, E.; Davidson, S.; Harford, M.; Jorge, J.; Watkinson, P.; Young, D.; Tarassenko, L.; Villarroel, M. Pulse arrival time as a surrogate of blood pressure. Sci. Rep. 2021, 11, 22767. [Google Scholar] [CrossRef]
  67. Athaya, T.; Choi, S. A Review of Noninvasive Methodologies to Estimate the Blood Pressure Waveform. Sensors 2022, 22, 3953. [Google Scholar] [CrossRef]
  68. Ismail, S.N.A.; Nayan, N.A.; Jaafar, R.; May, Z. Recent Advances in Non-Invasive Blood Pressure Monitoring and Prediction Using a Machine Learning Approach. Sensors 2022, 22, 6195. [Google Scholar] [CrossRef]
  69. Saugel, B.; Kouz, K.; Hoppe, P.; Maheshwari, K.; Scheeren, T.W.L. Predicting hypotension in perioperative and intensive care medicine. Best Pract. Res. Clin. Anaesthesiol. 2019, 33, 189–197. [Google Scholar] [CrossRef]
  70. Wijnberge, M.; van der Ster, B.J.P.; Geerts, B.F.; de Beer, F.; Beurskens, C.; Emal, D.; Hollmann, M.W.; Vlaar, A.P.J.; Veelo, D.P. Clinical performance of a machine-learning algorithm to predict intra-operative hypotension with noninvasive arterial pressure waveforms: A cohort study. Eur. J. Anaesthesiol. 2021, 38, 609–615. [Google Scholar] [CrossRef]
  71. Wijnberge, M.; Geerts, B.F.; Hol, L.; Lemmers, N.; Mulder, M.P.; Berge, P.; Schenk, J.; Terwindt, L.E.; Hollmann, M.W.; Vlaar, A.P.; et al. Effect of a Machine Learning-Derived Early Warning System for Intraoperative Hypotension vs. Standard Care on Depth and Duration of Intraoperative Hypotension During Elective Noncardiac Surgery: The HYPE Randomized Clinical Trial. JAMA 2020, 323, 1052–1060. [Google Scholar] [CrossRef]
  72. Maheshwari, K.; Shimada, T.; Yang, D.; Khanna, S.; Cywinski, J.B.; Irefin, S.A.; Ayad, S.; Turan, A.; Ruetzler, K.; Qiu, Y.; et al. Hypotension Prediction Index for Prevention of Hypotension during Moderate- to High-risk Noncardiac Surgery. Anesthesiology 2020, 133, 1214–1222. [Google Scholar] [CrossRef]
Figure 1. Artificial intelligence and continuous blood pressure monitoring. The figure shows two applications of artificial intelligence that can be used to predict hypotension or identify distinct endotypes of hypotension.
Figure 1. Artificial intelligence and continuous blood pressure monitoring. The figure shows two applications of artificial intelligence that can be used to predict hypotension or identify distinct endotypes of hypotension.
Medicina 59 01299 g001
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Bergholz, A.; Greiwe, G.; Kouz, K.; Saugel, B. Continuous Blood Pressure Monitoring in Patients Having Surgery: A Narrative Review. Medicina 2023, 59, 1299. https://doi.org/10.3390/medicina59071299

AMA Style

Bergholz A, Greiwe G, Kouz K, Saugel B. Continuous Blood Pressure Monitoring in Patients Having Surgery: A Narrative Review. Medicina. 2023; 59(7):1299. https://doi.org/10.3390/medicina59071299

Chicago/Turabian Style

Bergholz, Alina, Gillis Greiwe, Karim Kouz, and Bernd Saugel. 2023. "Continuous Blood Pressure Monitoring in Patients Having Surgery: A Narrative Review" Medicina 59, no. 7: 1299. https://doi.org/10.3390/medicina59071299

Article Metrics

Back to TopTop