Next Article in Journal
Remaining Useful Life Estimation of Hollow Worn Railway Vehicle Wheels via On-Board Random Vibration-Based Wheel Tread Depth Estimation
Next Article in Special Issue
Reduction in the Sensor Effect on Acoustic Emission Data to Create a Generalizable Library by Data Merging
Previous Article in Journal
Surface-Enhanced Raman Spectroscopy Using a Silver Nanostar Substrate for Neonicotinoid Pesticides Detection
Previous Article in Special Issue
A Comparison of Two Types of Acoustic Emission Sensors for the Characterization of Hydrogen-Induced Cracking
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Enhancing Structural Health Monitoring with Acoustic Emission Sensors: A Case Study on Composites under Cyclic Loading

Korea Atomic Energy Research Institute, 111 Daedeok-daero 989-gil, Yusenong-gu, Daejeon 34057, Republic of Korea
*
Author to whom correspondence should be addressed.
Sensors 2024, 24(2), 371; https://doi.org/10.3390/s24020371
Submission received: 29 November 2023 / Revised: 4 January 2024 / Accepted: 6 January 2024 / Published: 8 January 2024

Abstract

:
This study conducts an in-depth analysis of the failure behavior of woven GFRP under cyclic loading, leveraging AE sensors for monitoring damage progression. Utilizing destructive testing and AE methods, we observed the GFRP’s response to varied stress conditions. Key findings include identifying distinct failure modes of GFRP and the effectiveness of AE sensors in detecting broadband frequency signals indicative of crack initiation and growth. Notably, the Felicity effect was observed in AE signal patterns, marking a significant characteristic of composite materials. This study introduces the Ibe-value, based on statistical parameters, to effectively track crack development from inception to growth. The Ibe-values potential for assessing structural integrity in composite materials is highlighted, with a particular focus on its variation with propagation distance and frequency-dependent attenuation. Our research reveals challenges in measuring different damage modes across frequency ranges and distances. The effectiveness of Ibe-values, combined with the challenges of propagation distance, underscores the need for further investigation. Future research aims to refine assessment metrics and improve crack evaluation methods in composite materials, contributing to the field’s advancement.

1. Introduction

Structural health monitoring (SHM) has proven to be a valuable system for evaluating the abnormal conditions of structures such as nuclear power plants [1,2] and steam generators [3]. It primarily focuses on implementing damage identification strategies and is considered a promising system for assessing structural damage in real time [4,5]. SHM utilizes tools to assess changes in the structure, supporting engineers in maintaining the structural integrity of the facility continuously throughout its lifecycle. As a result, SHM systems have the potential to enhance reliability by reducing maintenance costs, preventing irreparable damage, and alleviating economic burdens. For these reasons, SHM is being applied in various fields such as wind power systems [6,7], high-pressure gas pipelines [8,9], and composite overwrapped pressure vessels (COPVs) [10]. However, despite the existence of various methodologies for sensor data analysis, they have not yet been widely used in the field. Therefore, continuous research is needed to refine these analysis techniques and evaluate their applicability and usefulness in real-world failure scenarios.
Most SHM systems are applied to assess abnormal conditions in locations that are inaccessible to non-destructive testing experts or during operation, making passive sensors suitable. Representative passive sensors include accelerometers and acoustic emission (AE) sensors [11,12,13,14]. Accelerometers are used to detect and measure the motion state of objects, including acceleration, velocity, and displacement. The impact of environmental factors is very important in the structural health assessment of engineering structures [15]. Particularly, factors such as temperature and noise can influence the dynamic characteristics of a structure and may obscure vibration signal changes caused by actual structural damage. This poses a particularly challenging problem for structural health assessment methods using accelerometers. AE sensors are used to assess physical changes, such as when AE manifests in the form of elastic waves, which occur when waves generated by stress changes inside the material reach the surface of the structure. AE signals that include information on abnormal conditions caused by environmental factors are important for the early detection and prevention of potential damage or defects within a structure [16]. This is because AE signals originate from the damage process itself. Therefore, by using AE parameters, it is possible to distinguish and analyze various issues within a structure, such as crack growth [17,18], corrosion [19], friction [20] and noise sources [16]. As a result, AE parameters become essential tools for maintaining the integrity of a structure and managing potential risks. For these reasons, AE sensors are applied to structural health monitoring (SHM) in various applications [16], including monitoring rock [16], concrete [21,22,23], and composite materials [24,25].
AE signals are converted into various AE parameters. The threshold-based AE-hit detection method functions by comparing the AE signal with a designated threshold, and any signal exceeding this threshold is identified as an AE-hit. Once an AE-hit is determined, three parameters become important: Hit definition time (HDT), hit lockout time (HLT), and peak definition time (PDT), which help in identifying the maximum amplitude and energy. Research is ongoing to interpret meaning from AE parameters. Ridge et al. [26] and Nair et al. [27] used amplitude and strength to assess damage in concrete samples, while Salamone et al. [28] applied statistical pattern recognition techniques to AE signals to identify the onset of damage. Ohtsu et al. [29] utilized AE energy and the Kaiser effect to study the damage state of RC beams under incremental cyclic loading. Colombo et al. [30] analyzed the fracture process in RC beams using the b-value based on the Gutenberg-Richter empirical formula [31], stating that changes in the b-value are associated with microcracks and macrocracks, and the b-value decreases as cracks grow. The Gallego research group applied AE testing to concrete [32,33] and FRP-reinforced wood beams [34] and proposed an SHM method based on the relationship between accumulated AE energy and plastic strain energy. This group empirically validated this methodology through several earthquake tests conducted on concrete structures, including RC structures with hysteresis dampers [35].
Recently, the energy b-value (be-value), which evaluates concrete cracks using AE hits and energy, has been successfully introduced [36]. However, its application in other areas, such as composite materials, has not yet been reported. Therefore, we assessed the applicability of the be-value using woven GFRP (glass fiber reinforced polymer), commonly used in high-pressure piping and COPVs. Through this research, we aim to propose a method for supporting nuclear power systems or evaluating the structural integrity of mechanical systems that are planned to be supported. Analyzing bursts of AE signals generated from cracks through frequency analysis allows for the distinction of damage modes. Representative failure modes such as matrix cracking, interfacial failure, and fiber fracture are known to primarily occur in distinct frequency ranges of 100–220 kHz, 240–360 kHz, and 380–500 kHz, respectively [37,38,39,40,41]. Additionally, the frequency of AE signals exhibits characteristics of attenuation with respect to propagation distance, referred to as the frequency-dependent attenuation of AE signals (Figure 1) [42,43,44]. As a result, the ratio of amplitude, energy, and hits of AE signals measured from AE sensors installed at different locations from the crack changes. In other words, the be-value may vary depending on the signal’s propagation distance. This phenomenon can occur not only in FRP but also in structures made using welding or cladding techniques.
However, there are still no research results that have been applied and evaluated in engineering structures or composite materials. In this study, we conducted destructive tests and AE testing using woven GFRP simultaneously. We varied the distance from the center hole to the sensors and observed changes in the be-value. Through this research, we aim to evaluate the applicability of the be-value. These results can be valuable not only for composite structures but also for mechanical structures where various abnormal conditions occur simultaneously. They can also provide important insights for improving the be-value.

2. Experimental Procedure

2.1. Fracture Testing

We used woven GFRP to generate broadband AE signals from a single crack, which originated from various defects. The 2 mm thick woven GFRP, made of woven glass fibers and epoxy resin, was purchased from Murakami Dengyo Co., Ltd. in Shizuoka, Japan. This flat plate was produced using pre-preg woven glass fibers (52.3 vol%) and was laminated with 16 plies, then compression-molded at 170 degrees Celsius.
Here is a step-by-step description of the experimental procedure (Figure 2):
  • Material: GFRP sheets with a 2 mm thickness, comprising glass fibers and epoxy resin arranged in a plain-woven fabric configuration.
  • Specimen Design: Woven GFRP plate specimens designed according to ASTM D3039 standards [45], including a center hole. The hole is created using a drill specifically designed for composite materials, resulting in a 2 mm-diameter hole at the center.
  • Prevention of Damage: GFRP tabs are attached to each end of the specimen to prevent damage from the test jig.
  • Tensile Testing: A universal testing machine (AGI; Shimadzu Corp., Kyoto, Japan) is employed for conducting the tensile tests. The crosshead speed is set at 1 mm/min (tensile loading), with cyclic loading at 10 mm/min.
Figure 3 shows the fracture surface of a woven GFRP specimen that failed due to cyclic loading. Near the center hole, matrix cracking, interfacial failure, and fiber fracture were observed. Consequently, the AE sensors detected signals of broadband frequencies originating from more than three defects [37,38].

2.2. AE Testing

AE testing was conducted using the following equipment and procedures:
  • Digitizer and Preamplifiers: AE signals were recorded using a digitizer (Physical Acoustics Corp.; PCI-2, Princeton Junction, NJ, USA) with a per-channel sampling rate of 10 MHz during each test. The tests utilized 2/4/6 preamplifiers (Physical Acoustics Corp., Princeton Junction, NJ, USA) with a 40 dBAE gain.
  • AE sensor: For AE testing, a PICO sensor from the Physical Acoustics Corporation (PAC; Princeton Junction, NJ, USA) was selected. This sensor operated within the frequency range of 200 to 750 kHz. Three AE sensors, referred to as data sensors, were strategically positioned at various distances from the hole on each specimen (refer to Figure 2). Guard sensors (labeled as sensor 4 and sensor 5) were applied at both ends of the specimen to enhance signal reliability. The utilization of guard sensors in testing represented a strategic approach to enhance signal reliability. These guard sensors were deployed to identify sources originating outside the area of interest. The guard technique entailed placing data sensors within the area of interest, encircled by multiple guard sensors [16]. Such a configuration allowed for a clear distinction between waves emanating from the area of interest and those from external sources. AE waves from the area of interest reached the data sensors before impacting any of the guard sensors. In contrast, waves originating from outside struck at least one of the guard sensors before reaching the data sensors. This setup facilitated the exclusion of external noise, enabling a focused analysis of pertinent acoustic emissions from the specimen under test.
  • Sensor attachment: The AE sensors were affixed to each specimen using silicon grease (HIVAC-G, Tokyo, Japan) and secured with vinyl tape.
  • Fracture occurrence: Specimens experienced fractures near the center hole due to stress concentration, leading to Table 1, which summarizes the test conditions based on previous research for AE monitoring.
  • Recording Criteria: AE signals exceeding 40 dBAE, as measured by the sensors, were recorded. This criterion helped filter out background noise and focus on relevant signals associated with the specimen’s behavior.
2.3. b-Value Analysis
The b-value analysis, initially developed by Gutenberg for seismological applications, is expressed by the formula [31]:
log 10 ( N ) = a b × A
Here, A represents the amplitude of the AE signal in decibels (dBAE), N represents the total number of AE hits, a is an empirical constant, and b is the slope of the linear relationship. This analysis uses amplitude as a direct indicator of damage, associating a decrease in the b-value with crack growth. To further enhance the analysis, the Ib-value [46] was introduced, considering specific statistical parameters of the amplitude distribution. The Ib-value is calculated using the mean (μ), standard deviation (σ), lower amplitude (μa1 × σ), and upper amplitude (μ + a2 × σ) values:
I b = log 10 N μ a 1 · σ log 10 N μ + a 2 · σ a 1 + a 2 · σ
Sagasta et al. [36] proposed the energy b-value (be):
log 10 N ( A E e ) = a b e × log 10 A E e
This proposed be-value assesses local damage in reinforced concrete structures under dynamic loads. It is based on the traditional b-value but uses the true energy of AE signals instead of the peak amplitude. Experimental applications demonstrate its potential for damage assessment, with the be-value responding when severe damage occurs in critical areas of the structure.
In the AE field, often considered microseismology, the b-value is extensively used to assess fracture processes. Similar to its application in engineering, the b-value in AE is associated with the number and amplitude of events. High b-values are linked to numerous small-amplitude AE events, like those from microcrack formation and slow crack growth, while low b-values indicate faster-growing or unstable crack formation. The b-value systematically changes during various stages of the fracture process, serving as a valuable indicator for estimating failure development. The composite material used in this study has a wide-frequency range, so it is necessary to select representative intervals and use their values. Therefore, Equation (2) was adopted into Equation (3) and defined as follows, where a1 = a2 = 3. The definition is illustrated in Figure 4.

3. Results and Discussion

Figure 5a illustrates the stress–strain curve of GFRP under tensile loading and cyclic loading. A tensile strength of 238 MPa was calculated for GFRP under tensile loading. By setting 70% of this value as the upper limit (197 MPa) and 45 MPa, the initial occurrence of AE signals, as the lower limit, the cyclic loading range was determined. The GFRP failed during the cyclic loading test at the 423rd cycle, with a stress of 188 MPa. This stress is lower compared to tensile loading, as fatigue failure occurs due to repetitive loading, leading to crack initiation and propagation. Simultaneously, this experiment provides insights into how the be-value responds to the occurrence and propagation of cracks.
During cyclic loading, AE signals are emitted from the crack growth to three sensors spaced at regular intervals from the center hole. The signals were recorded when each AE sensor exceeded 40 dBAE (threshold-based AE-hits technique, Figure 5b). PDT and HDT values of the AE signal were recorded as 50 microseconds and 150 microseconds, respectively. After calculating the burst duration time of the recorded AE signal, the energy of that interval was computed.
Figure 6 shows the results of converting the measured AE signals into AE energy during cyclic loading. In Figure 6a, AE energy progressively increased from 0 to 423 cycles. The AE energy of 7 eu recorded between 0 and 42 s is related to the formation of cracks. From 1931 s (9 eu) onward, a significant amount of AE energy is exclusively measured. This phenomenon is related to the Felicity effect, where AE signals are emitted before the previous maximum load. This occurrence is frequently observed in composite materials, including the GFRP specimen used in the test, indicating the growth of cracks. Until 3551 s, the maximum AE energy steadily increased to 707 eu, and this trend closely resembles the peak amplitude. Figure 6b,c shows the attenuated AE energy measured at propagation distances of 30 mm and 45 mm. These signals also consistently increased from the initiation of crack formation to the final failure. To clarify the attenuation effect, the cumulative hits of the calculated AE signals in Figure 6a–c were represented in Figure 6d. As the distance from the crack increased by 15 mm, the AE signals with AE energy decreased. However, the attenuation rate of the AE signals over time varied for each sensor. The failure behavior of composite materials is typically investigated to observe interface failure and fiber fracture occurring before matrix cracking [47,48]. Additionally, although the frequency ranges may vary among researchers [24,25,41], the general order is an increase in frequency corresponding to matrix cracking, interfacial failure, and fiber fracture. The AE signals generated near the final failure originate from matrix cracking, resulting in relatively low attenuation. On the other hand, a high attenuation ratio of matrix cracking and interfacial failure is observed in the crack initiation zone. For this reason, the difference in time–attenuation ratio (distance between the lines) is observed in Figure 6d.
Figure 7 shows the frequency distribution of the AE energy measured at Sensor 1 according to Equation (3). The be-value proposed by Sagasta et al. [36] utilizes the slope of the entire frequency distribution. Cracks in various materials, including composite materials, typically occur after the initiation of microcracks, followed by the development of macrocracks. From the perspective of AE signals, microcracking refers to the phenomenon characterized by the occurrence of numerous small-sized cracks. Therefore, in regions where microcracking predominates, a significant number of AE signals with low energy are generated, leading to a decrease in the be-value (3028 s to 3257 s). On the contrary, the occurrence of macrocracking, characterized by the formation of a single large-sized crack, results in an increase in the be-value (3257 s to 3440 s). The trend of increasing or decreasing be-values can be utilized to assess the structural integrity of a system, with an increase associated with microcracking and a decrease indicative of macrocracking. A similar occurrence is observed in the be-value proposed by Gutenberg et al. [31]. When computing the Ibe-value with Formula 3, we employed an interval of 0.02 for the frequency distribution and measured the slope after excluding non-accumulative intervals. We marked the representative interval of the frequency distribution, selected based on the mean and standard deviation, with an arrow at position 6. The slope was calculated using the method of least squares each time the AE signals reached multiples of 5.
Figure 8 displays the time series plot of Ibe-values along with stress. The calculation of Ibe-values commenced after the accumulation of 200 data points. The Ibe-values steadily decreased to 1.25 after the commencement of calculations. Unlike the dynamic approach of evaluating structural integrity using the trend of values, as seen in the b-value, the Ibe-value employs a more static method that heavily relies on the actual values. In a normal condition, the Ibe-value ranges from 3 to 2.75. As the material progresses from crack growth to final fracture, the Ibe-value decreases from 2.75 to 1.25. Many researchers assess the structural integrity by designating a specific value of Ib as the threshold for discontinuing the use of the structure. However, this study does not provide evaluation metrics as the Ibe-value was calculated using only a limited number of GFRP specimens. The most significant finding in this study is our confirmation of the powerful performance of the Ibe-value, demonstrating its potential for evaluating the structural integrity of composite materials using this method. On the other hand, the Ibe-value exhibited an overall decreasing trend as the propagation distance increased up to 45 mm. This phenomenon is attributed to the frequency dependence of the damping in the previously mentioned composite material. For a more detailed explanation, the AE energy frequency distribution measured up to 3028 s is illustrated in Figure 9a, concurrently with the representation of representative intervals based on Formula (3). Figure 9b illustrates the variations in peak frequency with propagation distance under identical conditions. The signals measured at Sensor 1 exhibited uneven attenuation over a propagation distance of 30 mm, leading to a change in the curve’s shape and consequently causing a variation in the Ibe-value. This phenomenon arises in the cracks of GFRP that exhibit broadband signals due to factors such as matrix cracking, interfacial failure, and fiber fracture. Each damage mode is characterized by a unique frequency and exhibits varying rates of attenuation. Consequently, it is observed that signals in the high-frequency range attenuate more rapidly than those in the low-frequency range [42,43,44]. This propagation characteristic is clearly depicted and validated in Figure 9b. Thus far, we have utilized the Ibe-value results obtained from AE signals emitted from the center hole as a basis for discussing the applicability of composite materials. It has been confirmed that the Ibe-value, along with previously proposed metrics such as be-value and Ibe-value, can be used to evaluate cracks in composite materials. However, since the values vary with the propagation distance, more extensive research is needed to understand this phenomenon.

4. Conclusions

In this study, we have conducted a comprehensive analysis of the failure behavior of woven GFRP under cyclic loading, utilizing AE sensors to monitor the progression of damage.
(1)
Our findings demonstrate that woven GFRP exhibits distinct failure modes when subjected to cyclic loading. The effectiveness of AE sensors in detecting broadband frequency signals from various failure modes provided valuable insights into the initiation and growth processes of cracks. A notable observation was the distinct presence of the Felicity effect, a characteristic of composite materials, in the AE signal patterns. Additionally, we observed that the AE signals attenuated with increasing distance from the crack source, which in this case was the center hole.
(2)
Employing the Ibe-value, which relies on statistical parameters, we were able to adeptly index the evolution of cracks from their formation to growth, originating from the center hole. One of the significant discoveries of this study is the potential application of the energy b-value in assessing the structural integrity of composite materials. However, we noted that the Ibe-value varied with the increase in propagation distance, a phenomenon attributed to the frequency dependence of attenuation.
This research has brought to light potential challenges that may be encountered when measuring different damage modes across various frequency ranges and at different propagation distances. The demonstrated effectiveness of Ibe-values, coupled with the identified challenges related to propagation distance, emphasizes the need for further investigations. These future studies would aim to refine assessment metrics and enhance the reliability of crack evaluation methods in composite materials.

Author Contributions

Conceptualization, D.J.; Investigation, J.L.; Data curation, D.J.; Writing—original draft, D.J.; Writing—review & editing, D.J. and J.L.; Visualization, D.J.; Project administration, J.L.; Funding acquisition, J.L. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Korea government (MOTIE), (20224B10100060, Development of artificial intelligence vibration monitoring system for rotating machinery).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data are contained within the article.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Upadhyaya, B.R.; Zhao, K.; Lu, B. Fault Monitoring of Nuclear Power Plant Sensors and Field Devices. Prog. Nucl. Energy 2003, 43, 337–342. [Google Scholar] [CrossRef]
  2. Hashemian, H.M. On-Line Monitoring Applications in Nuclear Power Plants. Prog. Nucl. Energy 2011, 53, 167–181. [Google Scholar] [CrossRef]
  3. Lu, B.; Upadhyaya, B.R.; Perez, R.B. Structural Integrity Monitoring of Steam Generator Tubing Using Transient Acoustic Signal Analysis. IEEE Trans. Nucl. Sci 2005, 52, 484–493. [Google Scholar]
  4. Doebling, S.W.; Farrar, C.R.; Prime, M.B.; Shevitz, D.W. Damage Identification and Health Monitoring of Structural and Mechanical Systems from Changes in Their Vibration Characteristics: A Literature Review; U.S. Department of Energy Office of Scientific and Technical Information: Oak Ridge, TN, USA, 1996. [Google Scholar]
  5. Avci, O.; Abdeljaber, O.; Kiranyaz, S.; Hussein, M.; Gabbouj, M.; Inman, D.J. A Review of Vibration-Based Damage Detection in Civil Structures: From Traditional Methods to Machine Learning and Deep Learning Applications. Mech. Syst. Signal Process 2021, 147, 107077. [Google Scholar] [CrossRef]
  6. Jin, X.; Chen, Y.; Wang, L.; Han, H.; Chen, P. Failure Prediction, Monitoring and Diagnosis Methods for Slewing Bearings of Large-Scale Wind Turbine: A Review. Measurement 2021, 172, 108855. [Google Scholar] [CrossRef]
  7. Tiboni, M.; Remino, C.; Bussola, R.; Amici, C. A Review on Vibration-Based Condition Monitoring of Rotating Machinery. Appl. Sci. 2022, 12, 972. [Google Scholar] [CrossRef]
  8. Mevissen, F.; Meo, M. A Review of NDT/Structural Health Monitoring Techniques for Hot Gas Components in Gas Turbines. Sensors 2019, 19, 711. [Google Scholar] [CrossRef]
  9. Li, S.; Wen, Y.; Li, P.; Yang, J.; Yang, L. Leak Detection and Location for Gas Pipelines Using Acoustic Emission Sensors. In Proceedings of the 2012 IEEE International Ultrasonics Symposium, Dresden, Germany, 7–10 October 2012; pp. 957–960. [Google Scholar]
  10. Gao, F.; Lin, J.; Ge, Y.; Lu, S.; Zhang, Y. A Mechanism and Method of Leak Detection for Pressure Vessel: Whether, When, and How. IEEE Trans. Instrum. Meas. 2020, 69, 6004–6015. [Google Scholar] [CrossRef]
  11. Calabrese, L.; Proverbio, E. A Review on the Applications of Acoustic Emission Technique in the Study of Stress Corrosion Cracking. Corros. Mater. Degrad. 2020, 2, 1–30. [Google Scholar] [CrossRef]
  12. Melchiorre, J.; Manuello Bertetto, A.; Rosso, M.M.; Marano, G.C. Acoustic Emission and Artificial Intelligence Procedure for Crack Source Localization. Sensors 2023, 23, 693. [Google Scholar] [CrossRef]
  13. Mandal, D.; Banerjee, S. Surface Acoustic Wave (SAW) Sensors: Physics, Materials, and Applications. Sensors 2022, 22, 820. [Google Scholar] [CrossRef] [PubMed]
  14. Hassani, S.; Dackermann, U. A Systematic Review of Advanced Sensor Technologies for Non-Destructive Testing and Structural Health Monitoring. Sensors 2023, 23, 2204. [Google Scholar] [CrossRef]
  15. Deng, Z.; Huang, M.; Wan, N.; Zhang, J. The Current Development of Structural Health Monitoring for Bridges: A Review. Buildings 2023, 13, 1360. [Google Scholar] [CrossRef]
  16. Mizutani, Y.; Enoki, M.; Inaba, H.; Nakamura, H.; Nakano, M.; Shigeishi, M.; Tomoki, S.; Shin-ichi, T. Practical Acoustic Emission Testing; Springer: Berlin/Heidelberg, Germany, 2016; ISBN 978-4-431-55071-6. [Google Scholar]
  17. Quy, T.B.; Kim, J.-M. Crack Detection and Localization in a Fluid Pipeline Based on Acoustic Emission Signals. Mech. Syst. Signal Process. 2021, 150, 107254. [Google Scholar] [CrossRef]
  18. Krampikowska, A.; Pała, R.; Dzioba, I.; Świt, G. The Use of the Acoustic Emission Method to Identify Crack Growth in 40CrMo Steel. Materials 2019, 12, 2140. [Google Scholar] [CrossRef] [PubMed]
  19. Verstrynge, E.; Van Steen, C.; Vandecruys, E.; Wevers, M. Steel Corrosion Damage Monitoring in Reinforced Concrete Structures with the Acoustic Emission Technique: A Review. Constr. Build. Mater. 2022, 349, 128732. [Google Scholar] [CrossRef]
  20. Khan, H.A.; Wang, K.; Pei, S.; Li, J.; Miller, S. Fatigue Damage Evolution of Micro Friction Stir Blind Riveting Joint through Acoustic Emission Analysis. Materialia 2019, 5, 100216. [Google Scholar] [CrossRef]
  21. Carpinteri, A.; Lacidogna, G.; Niccolini, G. Damage Analysis of Reinforced Concrete Buildings by the Acoustic Emission Technique. Struct. Control Health Monit. 2011, 18, 660–673. [Google Scholar] [CrossRef]
  22. Bunnori, N.M.; Lark, R.J.; Holford, K.M. The Use of Acoustic Emission for the Early Detection of Cracking in Concrete Structures. Mag. Concr. Res. 2011, 63, 683–688. [Google Scholar] [CrossRef]
  23. Bayane, I.; Brühwiler, E. Structural Condition Assessment of Reinforced-Concrete Bridges Based on Acoustic Emission and Strain Measurements. J. Civ. Struct. Health Monit. 2020, 10, 1037–1055. [Google Scholar] [CrossRef]
  24. Saeedifar, M.; Zarouchas, D. Damage Characterization of Laminated Composites Using Acoustic Emission: A Review. Compos. B Eng. 2020, 195, 108039. [Google Scholar] [CrossRef]
  25. Giordano, M.; Calabro, A.; Esposito, C.; D’Amore, A.; Nicolais, L. An Acoustic-Emission Characterization of the Failure Modes in Polymer-Composite Materials. Compos. Sci. Technol. 1998, 58, 1923–1928. [Google Scholar] [CrossRef]
  26. Ridge, A.; Ziehl, P. Nondestructive Evaluation of Strengthened RC Beams: Cyclic Load Test and Acoustic Emission Methods. ACI Struct. J. 2006, 1036, 832–841. [Google Scholar]
  27. Nair, A.; Cai, C.S. Acoustic Emission Monitoring of Bridges: Review and Case Studies. Eng. Struct. 2010, 32, 1704–1714. [Google Scholar] [CrossRef]
  28. Salamone, S.; Veletzos, M.J.; Lanza di Scalea, F.; Restrepo, J.I. Detection of Initial Yield and Onset of Failure in Bonded Posttensioned Concrete Beams. J. Bridge Eng. 2012, 17, 966–974. [Google Scholar] [CrossRef]
  29. Ohtsu, M. Acoustic Emission and Related Non-Destructive Evaluation Techniques in the Fracture Mechanics of Concrete: Fundamentals and Applications; Woodhead Publishing: Sawston, UK, 2020; ISBN 0128235144. [Google Scholar]
  30. Colombo, S.; Main, I.G.; Forde, M.C. Assessing Damage of Reinforced Concrete Beam Using “b-Value” Analysis of Acoustic Emission Signals. J. Mater. Civ. Eng. 2003, 15, 280–286. [Google Scholar] [CrossRef]
  31. Gutenberg, B. The Energy of Earthquakes. Q. J. Geol. Soc. 1956, 112, 1–14. [Google Scholar] [CrossRef]
  32. Benavent-Climent, A.; Gallego, A.; Vico, J.M. An Acoustic Emission Energy Index for Damage Evaluation of Reinforced Concrete Slabs under Seismic Loads. Struct. Health Monit. 2012, 11, 69–81. [Google Scholar] [CrossRef]
  33. Benavent-Climent, A.; Castro, E.; Gallego, A. AE Monitoring for Damage Assessment of RC Exterior Beam-Column Subassemblages Subjected to Cyclic Loading. Struct. Health Monit. 2009, 8, 175–189. [Google Scholar] [CrossRef]
  34. Rescalvo, F.J.; Suarez, E.; Valverde-Palacios, I.; Santiago-Zaragoza, J.M.; Gallego, A. Health Monitoring of Timber Beams Retrofitted with Carbon Fiber Composites via the Acoustic Emission Technique. Compos. Struct. 2018, 206, 392–402. [Google Scholar] [CrossRef]
  35. Cortés, G.; Suarez, E.; Gallego, A.; Benavent-Climent, A. Health Monitoring of Reinforced Concrete Structures with Hysteretic Dampers Subjected to Dynamical Loads by Means of the Acoustic Emission Energy. Struct. Health Monit. 2019, 18, 1836–1850. [Google Scholar] [CrossRef]
  36. Sagasta, F.; Zitto, M.E.; Piotrkowski, R.; Benavent-Climent, A.; Suarez, E.; Gallego, A. Acoustic Emission Energy B-Value for Local Damage Evaluation in Reinforced Concrete Structures Subjected to Seismic Loadings. Mech. Syst. Signal Process. 2018, 102, 262–277. [Google Scholar] [CrossRef]
  37. Bhat, C.; Bhat, M.R.; Murthy, C.R.L. Acoustic Emission Characterization of Failure Modes in Composites with ANN. Compos. Struct. 2003, 61, 213–220. [Google Scholar] [CrossRef]
  38. Chelliah, S.K.; Parameswaran, P.; Ramasamy, S.; Vellayaraj, A.; Subramanian, S. Optimization of Acoustic Emission Parameters to Discriminate Failure Modes in Glass–Epoxy Composite Laminates Using Pattern Recognition. Struct. Health Monit. 2019, 18, 1253–1267. [Google Scholar] [CrossRef]
  39. Guo, X.; Wang, Y.; Huang, P.; Chen, Z. Finite Element Modeling for Fatigue Life Prediction of RC Beam Strengthened with Prestressed CFRP Based on Failure Modes. Compos. Struct. 2019, 226, 111289. [Google Scholar] [CrossRef]
  40. Huang, C.; Ju, S.; He, M.; Zheng, Q.; He, Y.; Xiao, J.; Zhang, J.; Jiang, D. Identification of Failure Modes of Composite Thin-Ply Laminates Containing Circular Hole under Tension by Acoustic Emission Signals. Compos. Struct. 2018, 206, 70–79. [Google Scholar] [CrossRef]
  41. Eaton, M.; May, M.; Featherston, C.; Holford, K.; Hallet, S.; Pullin, R. Characterisation of Damage in Composite Structures Using Acoustic Emission. In Journal of Physics: Conference Series; IOP Publishing: Bristol, UK, 2011; Volume 305, p. 012086. [Google Scholar]
  42. Ni, Q.Q.; Iwamoto, M. Wavelet Transform of Acoustic Emission Signals in Failure of Model Composites. Eng. Fract. Mech. 2002, 69, 717–728. [Google Scholar] [CrossRef]
  43. Wirtz, S.F.; Bach, S.; Söffker, D. Experimental Results of Acoustic Emission Attenuation Due to Wave Propagation in Composites. In Proceedings of the Annual Conference of the PHM Society, Scottsdale, AZ, USA, 21–26 September 2019; Volume 23. [Google Scholar]
  44. Jang, D.; Kim, B.-J.; Nam, I.-W. A Comprehensive Study on EMI Shielding Performance of Carbon Nanomaterials-Embedded CFRP or GFRP Composites. Polymers 2022, 14, 5224. [Google Scholar] [CrossRef]
  45. ASTM D3039/D3039M-00; Standard Test Method for Tensile Properties of Polymer Matrix Composite Materials. American Society for Testing Materials (ASTM): West Conshohocken, PA, USA, 2017. [CrossRef]
  46. Shiotani, T.; Luo, X.; Haya, H.; Ohtsu, M. Damage Quantification for Concrete Structures by Improved B-Value Analysis of AE. In Proceedings of the 1th International Conference on Fracture (ICF11), Turin, Italy, 20–25 March 2005. [Google Scholar]
  47. Na, W.; Kwon, D.; Yu, W.R. X-ray Computed Tomography Observation of Multiple Fiber Fracture in Unidirectional CFRP under Tensile Loading. Compos. Struct. 2018, 188, 39–47. [Google Scholar] [CrossRef]
  48. Na, W.; Lee, G.; Sung, M.; Han, H.N.; Yu, W.R. Prediction of the Tensile Strength of Unidirectional Carbon Fiber Composites Considering the Interfacial Shear Strength. Compos. Struct. 2017, 168, 92–103. [Google Scholar] [CrossRef]
Figure 1. Effect of AE signal propagation characteristics from diverse damage modes on AE analysis: frequency dependence of attenuation.
Figure 1. Effect of AE signal propagation characteristics from diverse damage modes on AE analysis: frequency dependence of attenuation.
Sensors 24 00371 g001
Figure 2. Experimental procedure for analyzing broadband AE signals in woven GFRP specimens with central hole.
Figure 2. Experimental procedure for analyzing broadband AE signals in woven GFRP specimens with central hole.
Sensors 24 00371 g002
Figure 3. Fracture surface analysis of woven GFRP specimen under cyclic loading: observations of matrix cracking, interfacial failure, and fiber fracture.
Figure 3. Fracture surface analysis of woven GFRP specimen under cyclic loading: observations of matrix cracking, interfacial failure, and fiber fracture.
Sensors 24 00371 g003
Figure 4. Representation of Ibe-value for composite material in the study.
Figure 4. Representation of Ibe-value for composite material in the study.
Sensors 24 00371 g004
Figure 5. Behavioral analysis of woven GFRP under tensile and cyclic Loading: (a) stress–strain relationship and (b) acoustic emission signal response (See Table 1).
Figure 5. Behavioral analysis of woven GFRP under tensile and cyclic Loading: (a) stress–strain relationship and (b) acoustic emission signal response (See Table 1).
Sensors 24 00371 g005
Figure 6. Variation in AE Energy with Increasing AE signal propagation distance during cyclic loading of GFRP: (a) 15 mm, (b) 30 mm, (c) 45 mm, and (d) cumulative hits at each propagation distance.
Figure 6. Variation in AE Energy with Increasing AE signal propagation distance during cyclic loading of GFRP: (a) 15 mm, (b) 30 mm, (c) 45 mm, and (d) cumulative hits at each propagation distance.
Sensors 24 00371 g006
Figure 7. Change of frequency distribution.
Figure 7. Change of frequency distribution.
Sensors 24 00371 g007
Figure 8. Time series analysis of Ibe-values in relation to stress in woven GFRP: demonstrating the static evaluation approach for structural integrity.
Figure 8. Time series analysis of Ibe-values in relation to stress in woven GFRP: demonstrating the static evaluation approach for structural integrity.
Sensors 24 00371 g008
Figure 9. Frequency and attenuation characteristics of AE signals in woven GFRP: (a) AE energy frequency distribution and (b) peak frequency variation with propagation distance.
Figure 9. Frequency and attenuation characteristics of AE signals in woven GFRP: (a) AE energy frequency distribution and (b) peak frequency variation with propagation distance.
Sensors 24 00371 g009
Table 1. Test conditions for AE testing.
Table 1. Test conditions for AE testing.
ThresholdAmplifierAnalog FilterSampling Condition
TypedBAEdBAELowerUpperRatePDTHDT *
Fixed35401 kHz1 MHz10 MHz50 μsec1.5 k μsec
* HDT: recording time for each acoustic emission (AE) signal after the AE signal exceeded the threshold value.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Jung, D.; Lee, J. Enhancing Structural Health Monitoring with Acoustic Emission Sensors: A Case Study on Composites under Cyclic Loading. Sensors 2024, 24, 371. https://doi.org/10.3390/s24020371

AMA Style

Jung D, Lee J. Enhancing Structural Health Monitoring with Acoustic Emission Sensors: A Case Study on Composites under Cyclic Loading. Sensors. 2024; 24(2):371. https://doi.org/10.3390/s24020371

Chicago/Turabian Style

Jung, Doyun, and Jeonghan Lee. 2024. "Enhancing Structural Health Monitoring with Acoustic Emission Sensors: A Case Study on Composites under Cyclic Loading" Sensors 24, no. 2: 371. https://doi.org/10.3390/s24020371

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop