Next Article in Journal
Wearable xAI: A Knowledge-Based Federated Learning Framework
Previous Article in Journal
Multisensing Wearable Technology for Sweat Biomonitoring
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

Evaluation of the Electrochromic Response of Polypyrrole in the Presence of CO2 in the Solution †

by
Vilma Ratautaite
1,*,
Gintautas Bagdziunas
1,
Ernestas Brazys
2,
Almira Ramanaviciene
2,3 and
Arunas Ramanavicius
1,3
1
Laboratory of Nanotechnology, Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Sauletekio Av. 3, 10257 Vilnius, Lithuania
2
Department of Physical Chemistry, Institute of Chemistry, Vilnius University, Naugarduko 24, 03225 Vilnius, Lithuania
3
NanoTechnas—Center of Nanotechnology and Materials Science, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, 03225 Vilnius, Lithuania
*
Author to whom correspondence should be addressed.
Presented at the 8th International Symposium on Sensor Science, 17–28 May 2021; Available online: https://i3s2021dresden.sciforum.net/.
Published: 17 May 2021
(This article belongs to the Proceedings of The 8th International Symposium on Sensor Science)

Abstract

:
The indium tin oxide (ITO)-coated glass was used as a working electrode for electrochemical deposition of conducting polymer polypyrrole (Ppy). Before polymerization, the electrode surface was additionally modified with triethoxymethylsilane (TEMS) to provide better adhesion of polypyrrole to the surface of ITO. The polymerization of Ppy was performed electrochemically, regarding the previous studies. The ionic strength of the solution was supported by LiClO4. Since the dissolved CO2 in the solution forms weak acid and, thus, the pH of a solution can be slightly changed, the electrochromic response to the pH changes was evaluated. Britton–Robinson buffer (BRB) was used as the model system for an evaluation of the electrochromic response of polypyrrole at different pH values and concentrations of NaHCO3, which was a source of CO2 in the solution. For the evaluation of the electrochromic response in the presence of CO2, the double potential step chronoamperometry method was applied and UV-Vis absorption spectra were registered. To gain insight into the charge transfer phenomenon in more detail, the cyclic voltammetry experiments at different glass/ITO(TEMS)/Ppy electrode potential sweep rates were performed.

Supplementary Materials

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Some additional information is available on doi:10.1149/2.1221904jes.

Acknowledgments

This project has received funding from European Regional Development Fund (project No 01.2.2-LMT-K-718-01-0063) under grant agreement with the Research Council of Lithuania (LMTLT). Also, we are grateful to Mantas Žvirblis and Karolis Treinys for their assistance during experiments.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Ratautaite, V.; Bagdziunas, G.; Brazys, E.; Ramanaviciene, A.; Ramanavicius, A. Evaluation of the Electrochromic Response of Polypyrrole in the Presence of CO2 in the Solution. Eng. Proc. 2021, 6, 80. https://doi.org/10.3390/I3S2021Dresden-10128

AMA Style

Ratautaite V, Bagdziunas G, Brazys E, Ramanaviciene A, Ramanavicius A. Evaluation of the Electrochromic Response of Polypyrrole in the Presence of CO2 in the Solution. Engineering Proceedings. 2021; 6(1):80. https://doi.org/10.3390/I3S2021Dresden-10128

Chicago/Turabian Style

Ratautaite, Vilma, Gintautas Bagdziunas, Ernestas Brazys, Almira Ramanaviciene, and Arunas Ramanavicius. 2021. "Evaluation of the Electrochromic Response of Polypyrrole in the Presence of CO2 in the Solution" Engineering Proceedings 6, no. 1: 80. https://doi.org/10.3390/I3S2021Dresden-10128

Article Metrics

Back to TopTop