Article

Single Wall Carbon Nanotubes/Polypyrrole Composite Thin Film Electrodes: Investigation of Interfacial Ion Exchange Behavior

1
Laboratoire Interfaces et Systèmes Electrochimiques, LISE, UMR8235, Sorbonne Université, CNRS, F-75005 Paris, France
2
Facultad de Ingeniería en Sistemas, Electrónica e Industrial, Universidad Técnica de Ambato, Avenida los Chasquis y Río Payamino, Ambato 180103, Ecuador
*
Author to whom correspondence should be addressed.
J. Compos. Sci. 2021, 5(1), 25; https://doi.org/10.3390/jcs5010025
Submission received: 16 December 2020 / Revised: 7 January 2021 / Accepted: 11 January 2021 / Published: 14 January 2021
(This article belongs to the Special Issue Feature Papers in Journal of Composites Science in 2020)

Abstract

:
Single-wall carbon nanotubes/polypyrrole (SWCNT/PPy) composite thin-film electrodes were prepared by electrodeposition of the pyrrole monomer on a porous network made of SWCNT bundles. Electrode/electrolyte interface, which is intimately related to the pseudocapacitive charge storage behavior, is investigated by using coupled electrogravimetric methods (electrochemical quartz crystal microbalance (EQCM) and its coupling with electrochemical impedance spectroscopy, Ac-electrogravimetry), in a 0.5 M NaCl electrolyte (pH = 7). Our results show that the range of usable potential is greater for composite SWCNT/PPy films than for SWCNT films, which should allow a higher storage capacity to be obtained. This effect is also confirmed by mass variation measurements via EQCM. The mass change (corresponding to the amount of (co)electroadsorbed species) obtained with composite SWCNT/PPy films is four times greater than that observed for pristine SWCNT films if the same potential range is examined. The permselectivity is also greatly improved in the case of composite SWCNT/PPy films compared to SWCNT films; the former shows mainly cation exchange preference. The quantities of anions estimated by Ac-electrogravimetric measurements are much lower in the case of composites. This corroborates the better permselectivity of these composite SWCNT/PPy films even with a moderate amount of PPy.

1. Introduction

Polymers and polymeric composites are a unique class of materials, extensively used in numerous fields of applications such as electrochemical energy storage and conversion [1]. Due to their peculiar physicochemical and mechanical properties, these materials have been stimulating new research that aims at refining their structural, morphological and compositional characteristics to achieve the desired properties required for electrode or electrolyte materials used in energy devices [2,3].
Among them, supercapacitors (SCs) can provide a large amount of power in a relatively short time and can operate for a very high number of charge/discharge cycles and a longer lifetime than batteries [4,5]. These versatile attributes have led to their incorporation in a wide range of applications (such as city transit buses with stop-and-go driving, cranes and forklifts [6]). SC devices consist of two electrodes in contact with an electrolyte electrically isolated by a separator. During the charging process, the charges are stored and separated across the two electrode/electrolyte interfaces, which provides electric energy for the external load upon discharge. Briefly, SCs can be classified into two types with regard to their charge storage mechanism: electrical double-layer capacitors (EDLCs) and pseudocapacitors. EDLCs store charges by electrostatic adsorption of electrolyte ions at the electrode–electrolyte interface, typically use carbon materials as electrodes [7,8,9]. As for the pseudocapacitors, energy is stored by fast and reversible redox reactions between the electrolyte and electroactive species on the electrode surface at characteristic potentials, commonly employing transition metal oxides and conducting polymers (CPs) as electrode materials [10,11].
Due to their high conductivity, porosity and superior electrochemical stability, carbon materials are widely used as EDLC electrode materials [12], namely activated carbon (ACs), carbon nanotubes (CNTs) and graphene are the most studied examples. CNTs are of particular interest for the development of SC electrodes since they present unique tubular structures and superior electrical conductivity, mechanical, thermal and chemical stability [7]. CNTs have been considered as a promising candidate for high-power electrode material because of the aforementioned properties. In spite of the fact that the surface area of CNTs (800 m2·g−1) is small as compared to ACs (2000–3000 m2 g−1) [7,13], they can offer a reasonable specific capacitance [14], which is speculated to stem from their aligned pore structures, which, therefore, contribute to higher ion diffusion kinetics. Another option is the use of CNTs as support for electroactive materials because of their high mechanical resilience and open tubular network, which can form composite materials with metal oxides and/or CPs [15,16].
Regarding the electrode materials for pseudocapacitors, CPs are a very attractive solution due to their low price, non-toxicity and tunable chemical, electrical and physical properties. These polymers can be electrochemically doped in the presence of an electrolyte to obtain very good electrical conductivity (10 to 100 S.cm−1) and a wide electrochemical window. The most commonly used CPs for pseudocapacitive charge storage involve poly(3,4-ethylenedioxythiophene) (PEDOT) [17], polypyrrole (PPy) [18], polyaniline (PANI) [19], and polythiophene (PTh) [20]. Moreover, transitional metal oxides such as ruthenium oxide (RuO2) [21], MnO2 [22], ZnO [23], and NiO [24] have also been widely studied. Although the pseudo-capacitance can be much higher than EDL capacitance, it suffers from low-power density and poor stability upon cycling, which further highlights the interest of composite electrodes, uniting their benefits in a single electrode. In this context, a mix of carbon materials and CPs, merging the advantages of the two components, was evaluated in the field of pseudocapacitors. Indeed, a good electrical conductivity, a high specific surface area, a combination of charge storage mechanisms (associated with the electroadsorption and the Faradic reactions) and adequate control of the microstructuration can lead to synergetic effects which can drastically improve the electrochemical properties [25,26]. Different binary-composite films were assessed, employing various methods of preparation: high specific capacitances were attained with PANI-CNTs [27] or PEDOT-CNTs [28,29] composites; enhanced robustness of the flexible PPy-CNTs [30] or improved capacitive property of PTh-CNTs films [31] has also been revealed. Nevertheless, a deep understanding of the interfacial ionic transfer was not yet fully reached for these binary-composite materials. This is the reason why new methods of investigation are necessary to further improve their performances.
Taking into account the recent advances in the field of capacitive charge storage, on one hand, fabrication of composite electrodes with high specific surface area appears to be a key development path to achieve better SC performances. On the other hand, understanding the principles governing the ionic exchange mechanisms in nanostructured supercapacitor electrodes is equally important to shed light on this path and improve current devices. Therefore, suitable morphological, compositional as well as electrochemical characterization tools should be employed to assess composite electrode designs and the processes occurring at the electrode/electrolyte interface. For this purpose, various sophisticated analytical techniques have been developed to survey electrode–electrolyte interfaces that mainly govern the electrochemical operation of energy devices. Among them, the electrochemical quartz crystal microbalance (EQCM) [32,33,34,35,36] provides gravimetric changes of electrodes during electrochemical characterizations (such as charge/discharge) and offers valuable insights of the interfaces, once the required conditions of the deposited film in terms of viscoelastic and hydrodynamic properties are included [37,38,39].
Therefore, this work focuses on the understanding of the processes occurring at the electrode/–electrolyte interfaces of composite electrode materials by using EQCM-based coupled electrochemical methods. Carbon- and CP-based composites (SWCNT/PPy) are prepared by the electrochemical synthesis of doped polypyrrole on the single-wall CNT-based networks, the latter providing a high specific surface area. Interfacial properties are characterized not only with gravimetric EQCM but also with its coupling with electrochemical impedance spectroscopy (EIS), the so-called Ac-electrogravimetry [40,41]. This complementary method can deliver unique species-selective and frequency-dependent information about the ionic exchange mechanisms at the electrode/electrolyte interface [42,43,44]. The processes occurring at SWCNT/PPy composite electrode/electrolyte interface, which are related to their pseudo-capacitive charge storage behavior, are discussed in comparison to their pristine components (i.e., SWCNT [32] and PPy [45,46]).

2. Materials and Methods

2.1. Materials

Single-wall CNT (755117-1G, length: 300–2300 nm and diameter: 0.7–1.1 nm), sodium dodecyl sulfate (NaDS), pyrrole monomer, sodium chloride and N-methylpyrrolidone (NMP) solvent were acquired from Sigma-Aldrich. Poly(vinylidene fluoride)-co-hexafluoropropylene (PVDF-HFP) is obtained from Solef® 21508, Solvay Solexis, Milan, Italy.

2.2. SWCNT/Polypyrrole Composite Thin Film Electrode Preparation

In the first step, the SWCNT film preparation was performed based on a method described in the literature [47,48]. SWCNTs were deposited by the “drop-casting” on a gold electrode (effective surface area of 0.2 cm2) of a quartz crystal resonator (9 MHz, AW Sensors, Valencia, Spain), from a slurry containing 90% SWCNT powder and 10% PVDF-HFP (Poly(vinylidene fluoride-hexafluoropropylene)) polymer binder in N-methyl-2-pyrrolidone. A slurry containing 9 mg SWCNT powder, 1 mg of PVDF-HFP in 10 mL of NMP was ultrasonicated for about 20 min. Around 8 μL of this slurry was deposited on the gold electrode of the QCM. Then, the carbon films were subjected to a heat treatment at 120 °C for 30 min, with a heating rate of ~5 °C·min−1 to evaporate the residual solvent and improve the adhesion properties of the films on a gold electrode. The film thickness was estimated to be around 500 nm (based on field emission gun scanning electron microscopy (FEG-SEM) analyses, Figure 1). In a second step, the composite films of SWCNT/polypyrrole were obtained, following a method described in the literature [49]. The procedure consists of cycling the SWCNT electrode, previously prepared, in a solution containing 0.1 M pyrrole (freshly distilled) and 0.05 M sodium dodecyl sulfate (NaDS), at a scan rate of 0.01 V·s−1 in a potential range from 0 V to 0.675 V vs. Ag/AgCl during 2 cycles. The resulting films are taken out of the 3-electrode cell, rinsed with double distilled water and dried by purging with N2 flow.

2.3. Morphological and Physical Characterizations

Prior to the thin film preparation, the SWCNT powders were characterized using nitrogen adsorption (the specific surface area was estimated at ~842 m2·g−1, by using Brunauer–Emmett–Teller (BET) analysis), X-ray diffraction (XRD) and high-resolution transmission electron microscopy (HRTEM). The morphological and structural observations, not shown here, were already given in Reference [34]. The surface morphology of the SWCNT/polypyrrole, after thin-film formation on the gold electrode of the resonators, was investigated by field emission gun scanning electron microscopy (FEG-SEM) (Zeiss, Supra 55, Oberkochen, Germany).

2.4. Electrochemical and Electrogravimetric Characterizations

EQCM measurements were performed in 0.5 M NaCl (at pH = 7) in a three-electrode configuration. A lab-made QCM device was used to measure the microbalance frequency shift (∆f). Gold deposited on the quartz resonator was used as the working electrode. Platinum grid and Ag/AgCl (3 M KCl) was used as a counter and a reference electrode, respectively. The gravimetric conditions for the QCM analyses were assured by keeping film thickness acoustically thin (df < 500 nm) (Figure 1).
Ac-electrogravimetric measurements were also performed in the same three-electrode configuration described above. A four-channel frequency response analyzer (FRA, Solartron 1254) and a lab-made potentiostat (SOLETEM-PGSTAT) were used. The QCM was performed under a dynamic regime, and the modified working electrode was polarized at selected potentials to which a sinusoidal small-amplitude potential perturbation was superimposed. The frequency range was between 63 kHz and 10 mHz. The mass change, Δm, of the working electrode was measured simultaneously with the AC response, ΔI, of the electrochemical system, which led to the electrogravimetric (mass/potential) transfer function (TF), m E   ( ω ) , and the electrochemical impedance, E I   ( ω ) , to be obtained simultaneously at a given potential and frequency modulation, f (pulsation, ω = 2πf). The operation principle and the details of the Ac-electrogravimetric measurement setup have been described in previous papers [40,41,50].

3. Results and Discussion

3.1. Morphological Aspects of the SWCNT/PPy Composites

The SWCNT/PPy composite electrodes are prepared in a two-step process. In a first step, a thin layer of SWCNT is formed on the gold electrode of the quartz resonators by drop-casting a slurry containing SWCNT and PVDF-HFP as an active material and as a binder, respectively. The morphological characteristics of the SWCNT-modified QCM resonators were previously discussed [34]. Briefly, N2 adsorption analysis indicates that the SWCNTs have a pore diameter of 1–2 nm and a high specific surface area (~842 m2·g−1). Thin layers formed using these SWCNTs present a network of CNT bundles, made of at least ~10–20 CNTs [34]. In the second step, SWCNT-modified QCM resonators were used as a working electrode for the electropolymerization of pyrrole monomer, leading to the SWCNT/PPy composites. The surface morphology of SWCNT/polypyrrole (PPy) thin films was characterized by FEG-SEM, as shown in Figure 1. The images reveal a high-density of CNT bundles as it was already seen under the same film preparation conditions [34]. After two cycles (cyclic voltammetry) of PPy electrodeposition on the SWCNT-based electrodes, the formation of polypyrrole clusters with typical cauliflower or nodular morphology is observed in agreement with the previous studies [45], which is more evident on certain locations on the film surface (Figure 1a inset and Figure 2b, indicated with red arrows).
The cross-section of the SWCNT/PPy shown in Figure 1b permits the composite thin-film thickness (df) to be estimated. The thickness is slightly inhomogeneous along the thin film and presents a variation from 450 to 550 nm. The electrodeposited PPy component (only two cycles of electrodeposition) on the SWCNTs does not significantly change the film thickness, and therefore, the gravimetric conditions are kept for the QCM based analysis. It is important to note that the composite film thickness is mainly governed by the SWCNT layer under these experimental conditions. Although the exact location of PPy electrodeposition is difficult to pronounce, it likely occurs on the porous surface of the network formed by the SWCNTs, rather than forming a second compact layer on top of the former.

3.2. EQCM Study of the SWCNT/PPy Composites

Classical EQCM studies were already performed for pristine SWCNT films in NaCl electrolytes, as shown in [32,34]. In these experiments, the appropriate potential range was selected from –0.4 V vs. Ag/AgCl to 0.4 V vs. Ag/AgCl. The current response reveals a classic square shape with bumps, while the mass change corresponds to a V-shape type: in the cathodic part, a cation/solvent contribution is observed, and on the contrary, an anion/solvent contribution was distinguished in the anodic region. A permselectivity failure, indicating a mixed contribution of cations and anions, is also seen around the point of zero charges (PZC)/point of zero mass (PZM), corresponding to a potential of +0.1 V vs. Ag/AgCl. The maximum mass variation is less than 1 μg·cm−2 in the case of the cation response and starting from this potential reference. In light of these results, an EQCM analysis of the SWCNT/PPy composites was performed. The SWCNT/PPy composite film is oxidized and reduced between 0.45 V and −1.2 V vs. Ag/AgCl at three different scan rates of 25 mV·s−1, 50 mV·s−1 and 100 mV·s−1 in 0.5 M NaCl solution (pH = 7). Figure 2a,b show the corresponding current and the mass changes, respectively. A slight contribution of the PPy component is apparently observed in the CV responses (Figure 2a), as compared to that of pristine SWCNTs [32]. Indeed, the current evolution is smoother or less bumpy in the case of the composite film, for example, when the region around −0.2 V vs. Ag/AgCl is examined. On the contrary, the mass response of the film is totally different in terms of amplitude and shape. Previous EQCM studies on pristine SWCNT in the same electrolyte have shown a V-shaped mass response around the PZC, which is around 0.1 V vs. Ag/AgCl [32]. Instead, here, for the composite film, the mass response shows only one slope; even a larger potential range has been examined. When the composite film was reduced, a larger mass increase was observed: a factor of four is observed between the amplitudes of composite and pristine SWCNTs for the same potential range. On the other hand, the anion contribution is completely removed here for the same potential range (Figure 2b), which was observed for the pristine SWCNT film from +0.2 to +0.4 V vs. Ag/AgCl. When the composite film is oxidized, the mass decreases all the time, while in the case of pristine SWCNTs, the mass increases for the higher potentials revealing an anion contribution, as already demonstrated [32]. These qualitative remarks already show that the presence of PPy changes the interfacial ion-exchange behavior of the SWCNTs.
Figure 2c shows the F d m d q ( = F d m d t × 1 i )   function calculated from the EQCM data as a function of potential, which is equivalent to the global molar mass of the species obtained from the reduction branch in the range from 0.4 V to −1.2 V vs. Ag/AgCl in 0.5 M NaCl. At the cathodic potential region, the values vary in the range of 50–200 g·mol−1, which could correspond to Na+ with a high number of hydration or Na+ accompanied by free solvent molecules. However, at the anodic potentials, the values are smaller, and they vary in the range 0–50 g·mol−1, which is also difficult to be attributed to a single ion contribution (i.e., 23 g·mol−1 and 35 g·mol−1, for Na+ and Cl, respectively). Unfortunately, using EQCM alone to understand the interfacial process appears to be limited in the present case because the charge compensation can also be due to the concomitant insertion of anions or to solvated cations or to a mixture of these species. Dynamic approaches have the potential to reach a fair separation of these processes (identification by the kinetic transfers). For this reason, Ac-electrogravimetric investigations were performed to complement the EQCM and will be discussed in Section 3.3.
Figure 2d depicts the variation of specific capacitance values as a function of the applied potential under the same conditions as mentioned previously. The gravimetric specific capacitance values (Cs) are estimated to be around 25 to 30 F·g−1 in the range from −1.0 V to +0.45 V vs. Ag/AgCl. For very cathodic potentials, reduction of water interferes in the CV curves and thus, strongly modify the Cs values. Otherwise, these Cs are in the same order of magnitude as that obtained with pristine SWCNT thin-film electrodes [34,51,52].
A small dependence on the scan rate values is observed in the EQCM responses, which is more pronounced in the F d m d q the function is shown in Figure 2c. This result suggests that depending on the scan rate, different species may contribute to the electroadsorption and/or faradaic processes. Indeed, the information provided by the classical EQCM is insufficient for a thorough explanation of the transfer mechanism of the different species. As Ac-electrogravimetry was proven to be a strong complementary tool to EQCM in the previous CNT studies [32,33,34], the composite films were also analyzed with this technique. As mentioned earlier, this coupled tool can deliver unique species-selective and frequency-dependent information about the ion exchange mechanisms at the electrode/electrolyte interface.

3.3. Ac-Electrogravimetric Study of the SWCNT/PPy Composites

With the Ac-electrogravimetric approach, an EQCM response deconvolution was performed with the pristine SWCNT, as shown in references [32,34]. Briefly, the contribution of Na+.H2O, H+ and Cl were detected when the surface is negatively and positively charged, respectively. The faster interfacial transfer is obtained for the Na+.H2O and Cl species. H2O was observed at lower kinetics of transfer, whereas H+ was seen at very low values. In terms of quantities, major contributions are due to hydrated sodium with a quasi-equivalent contribution of water in the cathodic part and a lesser proton and chloride contributions. These findings are compared below to those obtained with the SWCNT/PPy composite electrodes.
The measurements were performed at each 200 mV in the range from 0.4 V to −1.2 V vs. Ag/AgCl in 0.5 M NaCl electrolyte. Figure 3 shows an example of the experimental and theoretical electrochemical transfer functions (TFs) obtained from Ac-electrogravimetry of an SWCNT/PPy thin film in 0.5 M NaCl electrolyte at −0.4 V vs. Ag/AgCl. The experimental data were fitted according to the model presented briefly in Appendix A (theoretical part). More details about the theory can be found in previous works [40,41]. A Mathcad software® was used to perform this step, assuring a good fitting for all the transfer functions measured at a given potential and by using the same set of parameters.
A good agreement between experimental data and theoretical curves are evident in Figure 3. The electrochemical impedance, E I   ( ω )   (Figure 3a), present a slightly distorted straight line at the lower frequency domain, indicating that there is a multi-ion transfer contribution. Therefore, it is difficult to extract information from this transfer function. The charge/potential transfer function, q E ( ω )   (Figure 3b), permit an easier separation of the ionic contributions, however, without any possibility to identify the ionic species involved. Figure 3b shows two loops, which can be attributed to at least two species, where their time constants are not sufficiently different from each other to obtain perfectly separated loops. Here, a big loop is observed around a characteristic frequency of 10 Hz, followed by a smaller one appearing at low frequencies. Equations (A1) and (A2) given in Appendix A were used here for the fitting process, assuming the contribution of two ions named c1 and c2. At this level, these two transfer functions, E I   ( ω )   and q E ( ω ) , are similar to those obtained with pristine SWCNTs under the same experimental conditions of measurements [32].
In the mass/potential transfer function, m E ( ω ) , one big loop appears in the third quadrant (Figure 4), which is characteristic for cation/solvated cation contributions or free solvent molecules in the same flux direction. In the fitting process of the experimental m E ( ω ) , three species are considered: Na+.nH2O at higher frequencies, free H2O molecules at intermediate frequencies and H+ at lower frequencies. The identification of these species was achieved by the determination of their molar mass, Mi, using Equation (A3) given in the theoretical part of Appendix A. The two parameters Ki and Gi, were already given by the electrochemical response for the two ionic species. For the free solvent, Ks and Gs are only estimated through the mass/potential transfer function, m E ( ω ) .
The contribution of three different species in the charge compensation process, estimated by fitting the experimental data, was further confirmed by carefully analyzing the partial electrogravimetric transfer function. For example, the cation 1, c1, the contribution is removed and   m E | c 2 s ( ω ) is calculated or the cation 2, c2, the contribution is removed and   m E | c 1 s ( ω ) is calculated (Equations (A3) and (A4)). Figure 5a,b exhibit a good agreement between the theoretical and experimental data. These partial electrogravimetric transfer functions provide a crosscheck for validating the hypothesis involving three different species and a better separation of the various contributions. If the molar masses chosen to identify the species are different from reality, a good agreement cannot be obtained. It should be noted that for   m E | c 1 s ( ω ) , a small loop appears in the fourth quadrant at low frequencies. According to our calculation, this response is related to the proton contribution, and normally, the cation response is located at the third quadrant of the Cartesian coordinates system. This difference is due to the mathematic treatment observed in Equation (A4) where a factor of Mc1-Mc2 appears; in our case, a negative value is obtained as the molar mass of c2 (hydrated sodium) is higher than the molar mass of c1 (proton). Thus, the response is located at this part of the complex plane, which appears as a virtual anion contribution. Since we have a perfect agreement for all the TFs, our model used in the fitting process is confirmed to be valid at this potential (−0.4 V vs. Ag/AgCl). This procedure was followed for different potentials in the potential range used for the EQCM measurements. The key parameters, Ki, Gi and Mi, are obtained for all the species involved directly or indirectly in the charge compensation process.
For potentials more cathodic than −0.3 V vs. Ag/AgCl, the contribution of only three species is found mixing the two cations, Na+.nH2O and H+, and free solvent molecules following the same transfer direction. On the contrary, for more anodic potential values, the proton contribution vanishes, and chloride species appear at very low frequencies.
Figure 6a,b display how the kinetic transfer rates, Ki, and the transfer resistance, Rti, of the species evolve as a function of the applied potential. The potential range corresponds to the conditions where the electroadsorption/desorption or insertion/expulsion processes of the thin film can be observed. The Ki values presented in Figure 6a indicate that the Na+.nH2O ion is the fastest of the four species. This observation may be correlated to an easier dehydration process of the sodium species compared to the protons. For the latter ions, it is noted that their corresponding interfacial transfer occurs at low frequencies. Additionally, the concentration of the protons in the electrolyte is much lower compared to that of sodium species at this pH value.
Furthermore, the kinetic transfer rates, Ks, of free water molecules are somewhat close to the values of the Na+.nH2O ions. As for the Cl ions, their transfer occurs at low frequencies and only at more anodic potentials.
In SWCNT/PPy composites, the kinetic transfer rates, Ki, of Na+.nH2O are significantly lower than the Ki of the Na+.nH2O in pristine SWCNTs [32] and higher than the Ki of the Na+ species detected in pristine PPy [45,49], measured under similar conditions. These results indicate that the composite structure does not hinder the sodium species transfer, and probably it is governed by the insertion process in PPy rather than a faster electroadsorption/desorption process. Additionally, the contribution of the sodium species to the charge compensation process (both electrostatic and faradaic) is enlarged to the whole potential range, i.e., 0.4 V to −1.2 V vs. Ag/AgCl (larger than that used for SWCNTs alone), but at the expense of their kinetics.
For the other species, the following trends were observed: (i) the kinetic transfer rates, Kc, of the H+ in the SWCNT/PPy are faster than the kinetic transfer rates of H+ in the SWCNT and (ii) the kinetic transfer rates, Ka, of the Cl in the SWCNT/PPy are more or less equivalent to the kinetic transfer rates of the Cl in the SWCNT [32] and in the pristine doped PPy [46].
In view of the transfer resistance values, Rti, of the ions, the Na+.nH2O species from the SWCNT/PPy are slightly more difficult to be transferred compared with the Na+.nH2O species in the SWCNT: 10 ohms·cm2 in Figure 6b versus 2 ohms·cm2, previously given in [32]. The Rti of H+ in the SWCNT/PPy composite is more or less equivalent to that in pristine SWCNT. The Rti of Cl in the SWCNT/PPy composite is comparable to that obtained in pristine SWCNT [32] and that found in doped PPy electrodes [46].
Taking into consideration of the Ki and Rti values of various species detected, one can suggest that there is no major hindrance of the ions transfer when doped PPy is deposited on the SWCNT electrodes. The species detected are related to the electroactivity of the two components. For example, at the anodic potentials, there is no cation contribution in pristine SWCNTs, whereas it exits in the composite structure due to the PPy.
Figure 7 displays the relative concentration change for the ionic species detected in the Ac-electrogravimetric measurements. The Ci-C0 values for H2O are significantly higher than the Ci-C0 values of Na+.nH2O, H+ and Cl. The relative concentration change of the Na+.nH2O in SWCNT/PPy is equivalent to the Ci-C0 values of the Na+.nH2O in pristine SWCNT. These values agree well with the Ci-C0 values of Na+ detected in doped PPy structures [46]. The same trend was observed for H+ and Cl anions, Ci-C0 values of the H+ and Cl did not significantly vary in the SWCNT/PPy composite compared to pristine SWCNTs [32]. The Ci-C0 values of the free solvent in the SWCNT–PPy composite are significantly higher than the Ci-C0 values of the free solvent in the SWCNT. These values are rather similar to that obtained for doped PPy thin films studied in our group [46], which indicates that the water transfer is principally governed by the doped PPy of the composite electrode.
Solely evaluating the electrochemical signatures of the pristine SWCNT and SWCNT/PPy composites does not allow us to distinguish the improvements in terms of interfacial species transfer behavior. Therefore, the main novelty of the present study is the way of characterization of the electrode/electrolyte interface by combining EQCM with simultaneous EIS measurements, providing a gravimetric and dynamic deconvolution of the interfacial processes. The results of the advanced electrogravimetric study revealed the differences between the pristine and composite electrodes relative to their charge compensation mechanism. The clarified points include the enlargement of the usable potential window and the enhanced permselectivity of the SWCNT/PPy composites compared to those of pristine SWCNTs, which could be revealed thanks to the advanced electrogravimetric tools (EQCM and its EIS coupling) used in our study.

4. Conclusions

Globally, the signature of PPy in the SWCNT/PPy composite is not very visible, both in current and mass response. Only after a closer examination, it can be seen that this composite SWCNT/PPy film has a much-improved response compared to pristine SWCNT and PPy films tested under the same conditions. These subtleties can be summarized as follows:
  • The range of usable potential is greater for composite SWCNT/PPy films than for SWCNT films, particularly for the cathodic part, since it is possible to push this limit further (more cathodic potentials than −0.6 V vs. Ag/AgCl) before reaching solvent degradation under the same experimental conditions. This should allow a higher storage capacity to be obtained. This effect is also confirmed by mass variation measurements via the responses given by the quartz microbalance tool;
  • The mass change obtained with composite SWCNT/PPy films is much higher than that observed for pristine SWCNT films if this mass variation is considered as a whole. However, this observation should be moderated because the most cathodic potential that can be achieved with these composite films is much lower compared to the tests on SWNCT films. Nevertheless, if the same potential range is examined, classically from −0.4 V vs. Ag/AgCl to +0.4 V vs. Ag/AgCl, the amount of (co)electroadsorbed species is still four times greater;
  • The permselectivity is also greatly improved in the case of composite SWCNT/PPy films compared to SWCNT films. This is, on one hand, confirmed by the shape of the ∆m-E response, given by the EQCM measurements, which is monotonically decreasing for composite SWCNT/PPy films while it has a classical “V” shape around the PZC for SWCNT films. The part corresponding to the most anodic potentials is mainly related to the electroadsorbed anions. In the case of the composite SWCNT/PPy films, this contribution is clearly very small. On the other hand, the quantities of anions estimated by Ac-electrogravimetric measurements are much lower in the case of composites. This corroborates the better permselectivity of these composite SWCNT/PPy films even with a moderate amount of PPy.

Author Contributions

F.E.-T. performed the experiments; H.P. and O.S. planned the experiments; F.E.-T., H.P and O.S analyzed the data; H.P. and O.S. contributed to the original draft preparation and revision; O.S. wrote, revised and edited the paper with discussions mainly with H.P. All authors have read and agreed to the published version of the manuscript.

Funding

F.E.-T. thanks the (Secrétariat National pour l’Enseignement Supérieur, la Science, la Technologie et l’Innovation (SENESCYT)-Equateur for the financial support during his Ph.D. thesis.

Acknowledgments

The authors thank Francoise Pillier for the FEG-SEM measurements.

Conflicts of Interest

The authors declare no conflict of interest.

Appendix A

The experimental data of the electrochemical impedance, E I   ( ω ) , and the charge/potential TF, q E   ( ω ) , were fitted using theoretical functions given in Equations (A1) and (A2). It is considered here that only two ions, c1 and c2, are involved in the charge compensation process.
E I | th   ( ω ) = [ j ω d f ( G c 1 j ω d f + K c 1 + G c 2 j ω d f + K c 2 ) ] 1
q E | th   ( ω ) = d f F ( G c 1 j ω d f + K c 1 + G c 2 j ω d f + K c 2 )
where df is the film thickness, Ki represents the kinetics rate of transfer, whereas Gi describes the level of difficulty corresponding to this transfer for each ionic species, c1 and c2 in our case, transferred at the electrode/electrolyte interface. For the parameter Gi, an analogy with a transfer resistance is generally used: R t i = 1 F G i .
The theoretical electrogravimetric transfer function, m E   ( ω ) , can be calculated, taking into account the charged/uncharged species contribution:
m E | th   ( ω ) = d f ( M c 1 G c 1 j ω d f + K c 1 + M c 2 G c 2 j ω d f + K c 2 + M s G s j ω d f + K s )
In Equation (A3), additional parameters, Ks and Gs for the solvent molecules are added as the molar mass (Mi) of each species.
From the theoretical overall electrogravimetric transfer function (Equation (A3)), it is possible to calculate the theoretical partial transfer functions by removing the c2 contribution, calculating m E | th c 1 s   ( ω ) ; or the c1 contribution, calculating m E | th c 2 s   ( ω ) , as shown in the following equations:
m E | th c 1 s   ( ω ) = d f ( ( M c 1 M c 2 ) G c 1 j ω d f + K c 1 + M s G s j ω d f + K s )
m E | th c 2 s   ( ω ) = d f ( ( M c 2 M c 1 ) G c 2 j ω d f + K c 2 + M s G s j ω d f + K s )

References

  1. Xue, Y.; Chen, S.; Yu, J.R.; Bunes, B.R.; Xue, Z.X.; Xu, J.K.; Lu, B.Y.; Zang, L. Nanostructured conducting polymers and their composites: Synthesis methodologies, morphologies and applications. J. Mater. Chem. C 2020, 8, 10136–10159. [Google Scholar] [CrossRef]
  2. Nair, S.S.; Mishra, S.K.; Kumar, D. Review—Polymeric materials for energy harvesting and storage applications. Polymer-Plastics Technol. Mater. 2020. [Google Scholar] [CrossRef]
  3. Simon, P.; Gogotsi, Y. Materials for electrochemical capacitors. Nat. Mater. 2008, 7, 845–854. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Miller, J.R.; Simon, P. Electrochemical Capacitors for Energy Management. Science 2008, 321, 651–652. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  5. Wang, G.; Zhang, L.; Zhang, J. A review of electrode materials for electrochemical supercapacitors. Chem. Soc. Rev. 2012, 41, 797–828. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  6. Miller, J.R.; Burke, A. Electrochemical Capacitors: Challenges and Opportunities for Real-World Applications. Electrochem. Soc. Interface 2008, 17, 53–57. [Google Scholar] [CrossRef]
  7. Zhang, L.L.; Zhao, X.S. Carbon-based materials as supercapacitor electrodes. Chem. Soc. Rev. 2009, 38, 2520–2531. [Google Scholar] [CrossRef]
  8. Béguin, F.; Presser, V.; Balducci, A.; Frackowiak, E. Carbons and Electrolytes for Advanced Supercapacitors. Adv. Mater. 2014, 26, 2219–2251. [Google Scholar] [CrossRef]
  9. Shao, H.; Wu, Y.-C.; Lin, Z.; Taberna, P.-L.; Simon, P. Nanoporous carbon for electrochemical capacitive energy storage. Chem. Soc. Rev. 2020, 49, 3005–3039. [Google Scholar] [CrossRef] [Green Version]
  10. Han, L.; Tang, P.; Zhang, L. Hierarchical Co3O4@PPy@MnO2 core–shell–shell nanowire arrays for enhanced electrochemical energy storage. Nano Energy 2014, 7, 42–51. [Google Scholar] [CrossRef]
  11. Xia, X.; Chao, D.; Fan, Z.; Guan, C.; Cao, X.; Zhang, H.; Fan, H.J. A New Type of Porous Graphite Foams and Their Integrated Composites with Oxide/Polymer Core/Shell Nanowires for Supercapacitors: Structural Design, Fabrication, and Full Supercapacitor Demonstrations. Nano Lett. 2014, 14, 1651–1658. [Google Scholar] [CrossRef] [PubMed]
  12. Simon, P.; Gogotsi, Y. Capacitive Energy Storage in Nanostructured Carbon–Electrolyte Systems. Acc. Chem. Res. 2013, 46, 1094–1103. [Google Scholar] [CrossRef] [PubMed]
  13. Davies, A.; Yu, A. Material advancements in supercapacitors: From activated carbon to carbon nanotube and graphene. Can. J. Chem. Eng. 2011, 89, 1342–1357. [Google Scholar] [CrossRef]
  14. An, K.H.; Kim, W.S.; Park, Y.S.; Choi, Y.C.; Lee, S.M.; Chung, D.C.; Bae, D.J.; Lim, S.C.; Lee, Y.H. Supercapacitors Using Single-Walled Carbon Nanotube Electrodes. Adv. Mater. 2001, 13, 497–500. [Google Scholar] [CrossRef]
  15. Li, P.; Yang, Y.; Shi, E.; Shen, Q.; Shang, Y.; Wu, S.; Wei, J.; Wang, K.; Zhu, H.; Yuan, Q.; et al. Core-Double-Shell, Carbon Nanotube@Polypyrrole@MnO2 Sponge as Freestanding, Compressible Supercapacitor Electrode. ACS Appl. Mater. Interfaces 2014, 6, 5228–5234. [Google Scholar] [CrossRef]
  16. Zeng, S.; Chen, H.; Cai, F.; Kang, Y.; Chen, M.; Li, Q. Electrochemical fabrication of carbon nanotube/polyaniline hydrogel film for all-solid-state flexible supercapacitor with high areal capacitance. J. Mater. Chem. A 2015, 3, 23864–23870. [Google Scholar] [CrossRef]
  17. Mo, D.; Zhou, W.; Ma, X.; Xu, J.; Zhu, D.; Lu, B. Electrochemical synthesis and capacitance properties of a novel poly(3,4-ethylenedioxythiophene bis-substituted bithiophene) electrode material. Electrochim. Acta 2014, 132, 67–74. [Google Scholar] [CrossRef]
  18. Feng, H.; Wang, B.; Tan, L.; Chen, N.; Wang, N.; Chen, B. Polypyrrole/hexadecylpyridinium chloride-modified graphite oxide composites: Fabrication, characterization, and application in supercapacitors. J. Power Sources 2014, 246, 621–628. [Google Scholar] [CrossRef]
  19. Liu, T.; Finn, L.; Yu, M.; Wang, H.; Zhai, T.; Lu, X.; Tong, Y.; Li, Y. Polyaniline and Polypyrrole Pseudocapacitor Electrodes with Excellent Cycling Stability. Nano Lett. 2014, 14, 2522–2527. [Google Scholar] [CrossRef]
  20. Ambade, R.B.; Ambade, S.B.; Shrestha, N.K.; Nah, Y.-C.; Han, S.-H.; Lee, W.; Lee, S.-H. Polythiophene infiltrated TiO2 nanotubes as high-performance supercapacitor electrodes. Chem. Commun. 2013, 49, 2308–2310. [Google Scholar] [CrossRef]
  21. Shen, J.; Li, T.; Huang, W.; Long, Y.; Li, N.; Ye, M. One-pot polyelectrolyte assisted hydrothermal synthesis of RuO2-reduced graphene oxide nanocomposite. Electrochim. Acta 2013, 95, 155–161. [Google Scholar] [CrossRef]
  22. Long, X.; Zeng, Z.; Guo, E.; Shi, X.; Zhou, H.; Wang, X. Facile fabrication of all-solid-state flexible interdigitated MnO2 supercapacitor via in-situ catalytic solution route. J. Power Sources 2016, 325, 264–272. [Google Scholar] [CrossRef]
  23. Bae, J.; Song, M.K.; Park, Y.J.; Kim, J.M.; Liu, M.; Wang, Z.L. Fiber supercapacitors made of nanowire-fiber hybrid structures for wearable/flexible energy storage. Angew. Chem. Int. Ed. Engl. 2011, 50, 1683–1687. [Google Scholar] [CrossRef]
  24. Wang, D.-W.; Li, F.; Cheng, H.-M. Hierarchical porous nickel oxide and carbon as electrode materials for asymmetric supercapacitor. J. Power Sources 2008, 185, 1563–1568. [Google Scholar] [CrossRef]
  25. Meng, Q.; Cai, K.; Chen, Y.; Chen, L. Research progress on conducting polymer based supercapacitor electrode materials. Nano Energy 2017, 36, 268–285. [Google Scholar] [CrossRef]
  26. Shown, I.; Ganguly, A.; Chen, L.-C.; Chen, K.-H. Conducting polymer-based flexible supercapacitor. Energy Sci. Eng. 2015, 3, 2–26. [Google Scholar] [CrossRef]
  27. Imani, A.; Farzi, G. Facile route for multi-walled carbon nanotube coating with polyaniline: Tubular morphology nanocomposites for supercapacitor applications. J. Mater. Sci. Mater. Electron. 2015, 26, 7438–7444. [Google Scholar] [CrossRef]
  28. Zhou, Y.; Xu, H.; Lachman, N.; Ghaffari, M.; Wu, S.; Liu, Y.; Ugur, A.; Gleason, K.K.; Wardle, B.L.; Zhang, Q.M. Advanced asymmetric supercapacitor based on conducting polymer and aligned carbon nanotubes with controlled nanomorphology. Nano Energy 2014, 9, 176–185. [Google Scholar] [CrossRef]
  29. Tahir, M.; He, L.; Haider, W.A.; Yang, W.; Hong, X.; Guo, Y.; Pan, X.; Tang, H.; Li, Y.; Mai, L. Co-Electrodeposited porous PEDOT–CNT microelectrodes for integrated micro-supercapacitors with high energy density, high rate capability, and long cycling life. Nanoscale 2019, 11, 7761–7770. [Google Scholar] [CrossRef] [PubMed]
  30. Chen, Y.; Du, L.; Yang, P.; Sun, P.; Yu, X.; Mai, W. Significantly enhanced robustness and electrochemical performance of flexible carbon nanotube-based supercapacitors by electrodepositing polypyrrole. J. Power Sources 2015, 287, 68–74. [Google Scholar] [CrossRef]
  31. Fu, C.; Zhou, H.; Liu, R.; Huang, Z.; Chen, J.; Kuang, Y. Supercapacitor based on electropolymerized polythiophene and multi-walled carbon nanotubes composites. Mater. Chem. Phys. 2012, 132, 596–600. [Google Scholar] [CrossRef]
  32. Escobar-Teran, F.; Arnau, A.; Garcia, J.V.; Jiménez, Y.; Perrot, H.; Sel, O. Gravimetric and dynamic deconvolution of global EQCM response of carbon nanotube based electrodes by Ac-electrogravimetry. Electrochem. Commun. 2016, 70, 73–77. [Google Scholar] [CrossRef]
  33. Escobar-Teran, F.; Perrot, H.; Sel, O. Charge storage properties of single wall carbon nanotubes/Prussian blue nanocube composites studied by multi-scale coupled electrogravimetric methods. Electrochim. Acta 2018, 271, 297–304. [Google Scholar] [CrossRef]
  34. Escobar-Teran, F.; Perrot, H.; Sel, O. Ion Dynamics at the Single Wall Carbon Nanotube Based Composite Electrode/Electrolyte Interface: Influence of the Cation Size and Electrolyte pH. J. Phys. Chem. C 2019, 123, 4262–4273. [Google Scholar] [CrossRef]
  35. Hillman, A.R. The EQCM: Electrogravimetry with a light touch. J. Solid State Electrochem. 2011, 15, 1647–1660. [Google Scholar] [CrossRef]
  36. Tsai, W.-Y.; Taberna, P.-L.; Simon, P. Electrochemical Quartz Crystal Microbalance (EQCM) Study of Ion Dynamics in Nanoporous Carbons. J. Am. Chem. Soc. 2014, 136, 8722–8728. [Google Scholar] [CrossRef] [Green Version]
  37. Shpigel, N.; Levi, M.D.; Sigalov, S.; Daikhin, L.; Aurbach, D. In Situ Real-Time Mechanical and Morphological Characterization of Electrodes for Electrochemical Energy Storage and Conversion by Electrochemical Quartz Crystal Microbalance with Dissipation Monitoring. Acc. Chem. Res. 2018, 51, 69–79. [Google Scholar] [CrossRef]
  38. Shpigel, N.; Levi, M.D.; Aurbach, D. EQCM-D technique for complex mechanical characterization of energy storage electrodes: Background and practical guide. Energy Storage Mater. 2019, 21, 399–413. [Google Scholar] [CrossRef]
  39. Levi, M.D.; Shpigel, N.; Sigalov, S.; Dargel, V.; Daikhin, L.; Aurbach, D. In Situ Porous Structure Characterization of Electrodes for Energy Storage and Conversion by EQCM-D: A Review. Electrochim. Acta 2017, 232, 271–284. [Google Scholar] [CrossRef]
  40. Gabrielli, C.; Garcia-Jareno, J.J.; Keddam, M.; Perrot, H.; Vicente, F. Ac-electrogravimetry study of electroactive thin films. II. Application to polypyrrole. J. Phys. Chem. B 2002, 106, 3192–3201. [Google Scholar] [CrossRef]
  41. Gabrielli, C.; García-Jareño, J.J.; Keddam, M.; Perrot, H.; Vicente, F. Ac-Electrogravimetry Study of Electroactive Thin Films. I. Application to Prussian Blue. J. Phys. Chem. B 2002, 106, 3182–3191. [Google Scholar] [CrossRef]
  42. Arias, C.R.; Debiemme-Chouvy, C.; Gabrielli, C.; Laberty-Robert, C.; Pailleret, A.; Perrot, H.; Sel, O. New Insights into Pseudocapacitive Charge-Storage Mechanisms in Li-Birnessite Type MnO2 Monitored by Fast Quartz Crystal Microbalance Methods. J. Phys. Chem. C 2014, 118, 26551–26559. [Google Scholar] [CrossRef]
  43. Lemaire, P.; Dargon, T.; Alves Dalla Corte, D.; Sel, O.; Perrot, H.; Tarascon, J.-M. Making Advanced Electrogravimetry as an Affordable Analytical Tool for Battery Interface Characterization. Anal. Chem. 2020, 92, 13803–13812. [Google Scholar] [CrossRef]
  44. Lemaire, P.; Sel, O.; Alves Dalla Corte, D.; Iadecola, A.; Perrot, H.; Tarascon, J.-M. Elucidating the Origin of the Electrochemical Capacity in a Proton-Based Battery HxIrO4 via Advanced Electrogravimetry. ACS Appl. Mater. Interfaces 2020, 12, 4510–4519. [Google Scholar] [CrossRef]
  45. Gao, W.L.; Sel, O.; Perrot, H. Electrochemical and viscoelastic evolution of dodecyl sulfate-doped polypyrrole films during electrochemical cycling. Electrochim. Acta 2017, 233, 262–273. [Google Scholar] [CrossRef]
  46. Benmouhoub, C.; Agrisuelas, J.; Benbrahim, N.; Pillier, F.; Gabrielli, C.; Kadri, A.; Pailleret, A.; Perrot, H.; Sel, O. Influence of the Incorporation of CeO2 Nanoparticles on the Ion Exchange Behavior of Dodecylsulfate Doped Polypyrrole Films: Ac-Electrogravimetry Investigations. Electrochim. Acta 2014, 145, 270–280. [Google Scholar] [CrossRef] [Green Version]
  47. Levi, M.D.; Salitra, G.; Levy, N.; Aurbach, D.; Maier, J. Application of a quartz-crystal microbalance to measure ionic fluxes in microporous carbons for energy storage. Nat. Mater. 2009, 8, 872–875. [Google Scholar] [CrossRef]
  48. Sigalov, S.; Levi, M.D.; Salitra, G.; Aurbach, D.; Jänes, A.; Lust, E.; Halalay, I.C. Selective adsorption of multivalent ions into TiC-derived nanoporous carbon. Carbon 2012, 50, 3957–3960. [Google Scholar] [CrossRef]
  49. Gabrielli, C.; Garcia-Jareño, J.J.; Perrot, H. Charge compensation process in polypyrrole studied by ac electrogravimetry. Electrochim. Acta 2001, 46, 4095–4103. [Google Scholar] [CrossRef]
  50. Gabrielli, C.; Perrot, H.; Rose, D.; Rubin, A.; Toque, J.P.; Pham, M.C.; Piro, B. New frequency/voltage converters for ac-electrogravimetric measurements based on fast quartz crystal microbalance. Rev. Sci. Instrum. 2007, 78. [Google Scholar] [CrossRef]
  51. Pan, H.; Li, J.; Feng, Y. Carbon Nanotubes for Supercapacitor. Nanoscale Res. Lett. 2010, 5, 654. [Google Scholar] [CrossRef] [Green Version]
  52. Pan, H.; Poh, C.K.; Feng, Y.P.; Lin, J. Supercapacitor Electrodes from Tubes-in-Tube Carbon Nanostructures. Chem. Mater. 2007, 19, 6120–6125. [Google Scholar] [CrossRef]
Figure 1. FEG-SEM images of single-wall carbon nanotubes/polypyrrole (SWCNT /PPy) nanocomposite film deposited on the gold electrode of a quartz resonator: (a) surface morphology with an inset showing the PPy clusters and (b) cross-section (red arrows point out the PPy clusters and orange colored arrows show the average film thickness).
Figure 1. FEG-SEM images of single-wall carbon nanotubes/polypyrrole (SWCNT /PPy) nanocomposite film deposited on the gold electrode of a quartz resonator: (a) surface morphology with an inset showing the PPy clusters and (b) cross-section (red arrows point out the PPy clusters and orange colored arrows show the average film thickness).
Jcs 05 00025 g001
Figure 2. EQCM results of SWCNT/PPy composite thin films: (a) current vs. potential; (b) mass variation vs. potential; (c) calculated F d m d q values vs. potential; (d) specific capacitance values (calculated from panel a) vs. potential. Measurements in aqueous electrolyte 0.5 M NaCl pH 7.0 at 3 different scan rates.
Figure 2. EQCM results of SWCNT/PPy composite thin films: (a) current vs. potential; (b) mass variation vs. potential; (c) calculated F d m d q values vs. potential; (d) specific capacitance values (calculated from panel a) vs. potential. Measurements in aqueous electrolyte 0.5 M NaCl pH 7.0 at 3 different scan rates.
Jcs 05 00025 g002
Figure 3. Experimental and theoretical electrochemical data of the SWNT/PPy thin film in 0.5 M NaCl measured at −0.4 V vs. Ag/AgCl: (a) electrochemical impedance, E I   ( ω )   and (b) charge/potential transfer function, q E ( ω ) . Theoretical functions were calculated with the following parameters: df = 0.4 µm, Kc1 = 9.50 × 10−5 cm·s−1, Gc1 = 7.98 × 10−9 mol·s−1·cm−2·V−1, Kc2 = 3.46 × 10−3 cm·s−1 and Gc2 = 9.3 × 10−7 mol·s−1·cm−2·V−1.
Figure 3. Experimental and theoretical electrochemical data of the SWNT/PPy thin film in 0.5 M NaCl measured at −0.4 V vs. Ag/AgCl: (a) electrochemical impedance, E I   ( ω )   and (b) charge/potential transfer function, q E ( ω ) . Theoretical functions were calculated with the following parameters: df = 0.4 µm, Kc1 = 9.50 × 10−5 cm·s−1, Gc1 = 7.98 × 10−9 mol·s−1·cm−2·V−1, Kc2 = 3.46 × 10−3 cm·s−1 and Gc2 = 9.3 × 10−7 mol·s−1·cm−2·V−1.
Jcs 05 00025 g003
Figure 4. Experimental and theoretical electrogravimetric transfer function, m E ( ω ) ,   of the SWNT/PPy thin film in 0.5 M NaCl measured at −0.4 V vs. Ag/AgCl. Theoretical function was calculated with the following parameters: df = 0.4 µm, Kc1 = 9.50 × 10−5 cm·s−1, Gc1 = 7.98 × 10−9 mol·s−1·cm−2·V−1, Kc2 = 3.46 × 10−3 cm·s−1, Gc2 = 9.3 × 10−7 mol·s−1·cm−2·V−1, Ks = 1.97 × 10−3 cm·s−1, Gs = 1.99 × 10−6 mol·s−1, Mc1 = 1 g·mol−1, Mc2 = 23 + 18 g·mol−1 and Ms = 18 g·mol−1.
Figure 4. Experimental and theoretical electrogravimetric transfer function, m E ( ω ) ,   of the SWNT/PPy thin film in 0.5 M NaCl measured at −0.4 V vs. Ag/AgCl. Theoretical function was calculated with the following parameters: df = 0.4 µm, Kc1 = 9.50 × 10−5 cm·s−1, Gc1 = 7.98 × 10−9 mol·s−1·cm−2·V−1, Kc2 = 3.46 × 10−3 cm·s−1, Gc2 = 9.3 × 10−7 mol·s−1·cm−2·V−1, Ks = 1.97 × 10−3 cm·s−1, Gs = 1.99 × 10−6 mol·s−1, Mc1 = 1 g·mol−1, Mc2 = 23 + 18 g·mol−1 and Ms = 18 g·mol−1.
Jcs 05 00025 g004
Figure 5. Partial electrogravimetric transfer function of the SWNT-PPy thin film in 0.5 M NaCl measured at −0.4 V vs. Ag/AgCl: (a)     m E | c 1 s ( ω ) cation1-solvent partial transfer function and (b)     m E | c 2 s ( ω ) cation2-solvent partial transfer function. Theoretical functions were calculated with the same set of parameters used previously for the data presented in Figure 3 and Figure 4.
Figure 5. Partial electrogravimetric transfer function of the SWNT-PPy thin film in 0.5 M NaCl measured at −0.4 V vs. Ag/AgCl: (a)     m E | c 1 s ( ω ) cation1-solvent partial transfer function and (b)     m E | c 2 s ( ω ) cation2-solvent partial transfer function. Theoretical functions were calculated with the same set of parameters used previously for the data presented in Figure 3 and Figure 4.
Jcs 05 00025 g005
Figure 6. The kinetic transfer constants, Ki, and transfer resistance, Rti, for all species estimated from the fitting of the Ac-electrogravimetric data of SWCNT/PPy composite measured in 0.5 M NaCl: (a) kinetic transfer constants, Ki and (b) transfer resistance, Rti.
Figure 6. The kinetic transfer constants, Ki, and transfer resistance, Rti, for all species estimated from the fitting of the Ac-electrogravimetric data of SWCNT/PPy composite measured in 0.5 M NaCl: (a) kinetic transfer constants, Ki and (b) transfer resistance, Rti.
Jcs 05 00025 g006
Figure 7. Evolution of the relative concentration, Ci-C0 of each species over the potential applied measured in 0.5 M NaCl SWCNT/PPy.
Figure 7. Evolution of the relative concentration, Ci-C0 of each species over the potential applied measured in 0.5 M NaCl SWCNT/PPy.
Jcs 05 00025 g007
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Escobar-Teran, F.; Perrot, H.; Sel, O. Single Wall Carbon Nanotubes/Polypyrrole Composite Thin Film Electrodes: Investigation of Interfacial Ion Exchange Behavior. J. Compos. Sci. 2021, 5, 25. https://doi.org/10.3390/jcs5010025

AMA Style

Escobar-Teran F, Perrot H, Sel O. Single Wall Carbon Nanotubes/Polypyrrole Composite Thin Film Electrodes: Investigation of Interfacial Ion Exchange Behavior. Journal of Composites Science. 2021; 5(1):25. https://doi.org/10.3390/jcs5010025

Chicago/Turabian Style

Escobar-Teran, Freddy, Hubert Perrot, and Ozlem Sel. 2021. "Single Wall Carbon Nanotubes/Polypyrrole Composite Thin Film Electrodes: Investigation of Interfacial Ion Exchange Behavior" Journal of Composites Science 5, no. 1: 25. https://doi.org/10.3390/jcs5010025

Article Metrics

Back to TopTop