Article

Soft Movable Polymer Gel for Controlling Water Coning of Horizontal Well in Offshore Heavy Oil Cold Production

1
School of Energy Resources, China University of Geosciences, Beijing 100083, China
2
School of Petroleum Engineering, China University of Petroleum (East China), Qingdao 266580, China
*
Authors to whom correspondence should be addressed.
Gels 2022, 8(6), 352; https://doi.org/10.3390/gels8060352
Submission received: 8 May 2022 / Revised: 25 May 2022 / Accepted: 31 May 2022 / Published: 5 June 2022
(This article belongs to the Special Issue Gels for Oil and Gas Industry Applications)

Abstract

:
Horizontal well water coning in offshore fields is one of the most common causes of rapid declines in crude oil production and, even more critical, can lead to oil well shut down. The offshore Y oil field with a water cut of 94.7% urgently needs horizontal well water control. However, it is a challenge for polymer gels to meet the requirements of low-temperature (55 °C) gelation and mobility to control water in a wider range. This paper introduced a novel polymer gel cross-linked by hydrolyzed polyacrylamide and chromium acetate and phenolic resin for water coning control of a horizontal well. The detailed gelant formula and treatment method of water coning control for a horizontal well in an offshore field was established. The optimized gelant formula was 0.30~0.45% HPAM + 0.30~0.5% phenolic resin + 0.10~0.15% chromium acetate, with corresponding gelation time of 26~34 h at 55 °C. The results showed that this gel has a compact network structure and excellent creep property, and it can play an efficient water control role in the microscopic model. The thus-optimized gelants were successively injected with injection volumes of 500.0 m3. The displacement fluid was used to displace gelants into the lost zone away from the oil zone. Then, the formed gel can be worked as the chemical packer in the oil–water interface to control water coning after shutting in for 4 days of gelation. The oil-field monitoring data indicated that the oil rate increased from 9.2 m3/d to 20.0 m3/d, the average water cut decreased to 60~70% after treatment, and the cumulative oil production could obtain 1.035 × 104 t instead of 3.9 × 103 t.

1. Introduction

Waterflooding is the most economical and commonly used method for oil fields, especially for offshore oil fields with high equipment investment [1,2,3]. Due to the reservoir heterogeneity, it is inevitable that injected water will break into the oil well at the later stage of development, resulting in a high water production rate. Multi-branch, long-distance horizontal wells are the main way of drilling and production in offshore oil fields [4,5,6,7,8]. This is mainly due to the rational use of the operation space, saving resources, and increasing the oil drainage area of the reservoir. Once the formation water enters the horizontal well, the water cut increases sharply. A high level of water production leads to an increase in corrosion and scale, a high load of fluid-handling facilities, and significant environmental protection concerns, which eventually results in shut-in wells without economic benefit [9,10,11,12]. Therefore, efficient and low-cost water control methods are particularly important for the development of offshore oil fields.
Polymer gel treatment is a cost-effective method to improve sweep efficiency in reservoirs and reduce excess water produced during oil and gas production. Polymer gel treatment can also improve the rheology and composition of crude oil [13,14,15,16]. The gel formed by polymer and cross-linker can be injected into the target formation with high water cut and fully or partially seal the formation at reservoir temperature [17,18,19,20]. Polymer gels prepared with chromium acetate or phenolic resin are commonly used and relatively stable systems, but their gelation temperatures are very different [21,22,23,24]. Polymer gels prepared with chromium acetate or phenolic resin are commonly used and relatively stable systems, but their gelation temperature is very different. The activation temperature of phenol/formaldehyde cross-linked by acrylamide-based copolymer is above 80 °C, which is suitable for use in middle-/high-temperature oil reservoirs. When the reservoir temperature is low, the cross-linking condensation reaction of this system will slow down, and better formation effects cannot be guaranteed [25,26]. Since the formation of brine will affect the gelation time and stability of the dynamic gel, the researchers tried to develop a salt-insensitive gel system using a special salt-insensitive modified polymer (PAN, PVA, PAMPS, PSSA, etc.) [27]. Metal-based cross-linking agents (Cr3+, Al3+) are widely used in low-temperature reservoirs due to their low price, but the gelation time will decrease rapidly with the increase in gel temperature, which will lead to the problem of an uneven density of cross-links and poor gel stability. Organometallic cross-linkers can increase gelation time by slow release of metal ions [28,29]. Although the gel reaction rate can be controlled to some extent, the gel formed by metal complexation has poor toughness. It is more susceptible to damage during formation migration [30]. Moreover, the polymer gel should have good deformability, in addition to meeting the conditions of gel strength and gelation time, which easily leads to deeply migrating into the water-yielding formation and plugging water channels for enhanced oil recovery. The low-temperature composite cross-linked soft movable polymer gel can be cross-linked multiple times after being destroyed during the migration process. This gel with excellent strength and creep properties is more suitable for controlling water coning of horizontal wells in offshore oil fields.
The Y oil field is an offshore heavy oil field that has been put into scale development. It is a Neogene marine sandstone reservoir. HX well is situated in the formation NgⅡ11+2. For the formation NgⅡ11+2, the reservoir temperature is 55 °C, the reservoir pressure is about 13.5 MPa, the average porosity is 30.0%, the effective permeability is 2.1 μm2, and the salinity of formation water is 34,178.2 mg/L. The effective thickness of the sandstone reservoir is about 8.4 m. There is a water layer with sufficient bottom water energy under the production layer (NgⅡ11+2), resulting in a sharp rise in the water content of the production well. Recently, the water cut of the HX well has been up to 100%. When the bottom water breaks through, the great adverse mobility ratio of water to oil also promotes a sharp increase in water production and a significant decrease in oil production. In order to control water production, most horizontal wells need to take measures to block water channels and increase oil production. In this study, a novel soft movable polymer gel was introduced for controlling water coning of horizontal well in offshore heavy oil cold production. The strength and creep properties of gel were investigated, and its rheology and micromorphology are evaluated. Additionally, the treatment strategy was simulated and verified through a microscopic visual model. The oil-field application was implemented using the optimized treatment, and finally, good application results were achieved.

2. Experimental

2.1. Experimental Materials

Partially hydrolyzed polyacrylamide (HPAM, Mw: 1.2 × 107 Da, degree of hydrolysis: ~23%), chromium acetate (Cr3+) acetate cross-linker, and phenolic resin (PR, Mw: 2 × 104~3 × 104 Da, sulfonation degree: ~20%) cross-linker were purchased from Shida Oil Field Service Company, Dongying, China. All samples were industrial grade (~95%). Y oil field HX well of reservoir temperature is 55 °C, and the formation water composition is shown in Table 1.

2.2. Preparation of Brine

High-density brine is an indispensable working fluid, which is usually determined by the density of the formation water. High-density brine is formulated by dissolving soluble inorganic salts. High-density brine used in oil-field construction usually has the following characteristics: (1) the density of brine is higher than that of the gelants; (2) the brine and formation water are compatible, and the viscosity is higher than that of the formation water; (3) the inorganic salts for preparing brine are cheap and environmentally friendly. Therefore, sodium chloride (NaCl) is an ideal water-soluble inorganic salt to prepare a high-density brine.
Gel and brine were prepared as the basis of the material, and then the performance of the gel was systematically studied. The flowchart of methodology is shown in Figure 1.

2.3. Optimum Formula of Soft Movable Polymer Gels

(1)
Gelation time
The polymer (0.3~0.45%) and cross-linker (0.3~0.6% PR + 0.05~0.20% Cr) were dissolved in tap water, and the pH value of the cross-linked glue solution is 6~6.5. Then, the mixed solution was placed in an oven at a temperature of 55 °C until the gel was completely gelled. Temperature triggered chromium ion release forms complex with a polymer carboxyl group, and phenolic resin is cross-linked with an amide group. Gelation time is the time when the gelants change from solution into code E according to the macroscopic visual inspection method (Sydansk’s method) commonly used in the oil field [31,32], as shown in Table 2. The gel strength was characterized by the code from A to G.
(2)
Water-plugging capacity
After the gelants enter the core pores, the polymer gels gelled by gelants can block the channeling channel. The water-plugging capacity was evaluated by comparing the permeability of the core after injection of gelants with the permeability of the original core. The schematic of the experimental setup is shown in Figure 2. The experimental procedures are as follows: (1) a sandbag was filled with dry sand as a reservoir unit, and its weight was measured; (2) the sandbag was evacuated overnight, saturated with water, and weighed. The volume of water (pore volume) was calculated from the mass of incoming water; (3) waterflooding was conducted, and the stable pressure was recorded; (4) 0.3 pore volume (PV) gelants were injected into a sand pack and placed into an oven, with reservoir temperature for a certain time; (5) waterflooding was implemented again, and the stable pressure was recorded; (6) the water-plugging capacity (C) and the residual resistance factor (Frr) of polymer gel were calculated, using Equations (1) and (2) as follows:
C = ( 1 k b / k a ) × 100 %
  F r r = k b / k a = Δ P a / Δ P b  
where kb—permeability of the sandbag before plugging; ka—permeability of the sandbag after plugging.

2.4. Creep Recovery Property

The creep and recovery properties of elastic polymer gels were measured using an MCR302 rheometer (Annton Parr Company, Germany), with a plate–plate at 55 °C. Constant shear stress of 2.4 Pa was applied on polymer gel, and the linear viscoelastic range was obtained. The strain of elastic polymer gel versus time was studied after eliminating the constant shear stress.

2.5. Microstructure of Gel

The gel microstructure was observed via environmental Quanta 200 FEG scanning electron microscopy (ESEM) (FEI Company, Hillsboro, OR, USA). During the experiments, a small piece of gel sample was directly placed on a covered ESEM grid at 25 °C.

2.6. Visual Physical Simulation Experiments

The visual physical model system was designed and built, as shown in Figure 3. The glass plate model consisted of an etched base glass plate combined with a cover glass plate, the boundaries of which were sealed with sealant. There were three ports at the bottom of the model—two water injection ports were located in the lower part, and one water outlet is located in the upper part. After the pumping device and the observation device were connected, the airtightness of the pipeline was checked, and the experiment of bottom-water coning and control in a horizontal well was simulated.

2.7. Flowchart of Soft Movable Polymer Gel for Controlling Water Coning in Horizontal Well

As shown in Figure 4, the horizontal well was located in the middle of the oil layer on a reservoir, and bottom water broke through and entered the wellbore from bottom to top (Figure 4a,b). Gravity separation is a core principle of controlling bottom-water coning technology, which relies on the density difference between fluids (oil and water) to cause gravity separation in the reservoir. In this study, first, high-density brine (0.99~1.02 g/cm3) was injected into the reservoir through the wellbore, and it mainly migrated to the water–oil transition zone to protect the polymer gel from entering the bottom of the water layer (Figure 4c). In the second step, the gelants with a density (0.97~0.98 g/cm3) between oil and brine were injected into the penetration zone (Figure 4d). Then, displacement fluid (~1.00 g/cm3) was injected to displace the gelants in the wellbore into the water coning zone and away from the oil layer of the reservoir (Figure 4e). Finally, after the displacement fluid was flushed away with fresh water from the mine, the horizontal well was shut in for gelation, completing a chemical gel packer (Figure 4f).

2.8. Construction Plan of HX Well

The water and oil production data of oil wells in recent years were first analyzed, after which the gel water control plan was determined. After calculating the usage of the three liquids, three working fluids had to be injected in sequence, mainly including high-density brine, gelants, and displacement fluid. The high-density brine was first injected into the bottom water layer to increase the density difference between the oil and water phases.
The gelants of polymer gel were injected into the bottom water layer through the water-cone water channel to act as a plug. The displacement fluid can drive the gelants of the wellbore and oil layer into the water layer to keep the oil flow channel unobstructed. After the injection of the three kinds of liquids, the HX well was shut in, which transformed the gelling agent form into a chemical gel packer near the interface between the oil and water layers, blocking the bottom-water coning. Finally, the data of water and oil production of oil wells after adopting gel water control were analyzed.

3. Results and Discussion

3.1. Density and Viscosity Properties of Brine

The density and viscosity of brine as a function of salt mass fraction were measured, as shown in Figure 5. The density of the brine should be higher than that of the formation water in Table 1, so the mass fraction of sodium chloride in the preparation of high-density brine should be higher than 8%. Furthermore, there are two factors to consider. On the one hand, high-density brine may have a negative impact on the gelation of the gelants; on the other hand, the density between the high-density saline and transition zone also decreases exponentially during high-density saline and gel injection. The calculation found that when the injected high-density saline was 8% NaCl solution, the transition-density saline was half of that in high-density saline.

3.2. Optimum Formula of Soft Movable Polymer Gels

Based on temperature (55 °C) and salinity conditions (34,178.2 mg/L) of the Y oil-field reservoir, a novel polymer gel prepared via HPAM + PR and Cr3+ cross-linker was investigated. The gelation time, gel strength, thermal stability, and water-plugging capacity of the soft movable polymer gels were tested, as shown in Figure 6 and Figure 7, and Table 3 and Table 4.
The experimental results showed that the gelation time of gel prepared using HPAM + PR and Cr3+ cross-linker was 15~50 h. Additionally, the gel strength of most gels was higher than code F. After aging for 30 days at 55 °C, the gel stability of these gels slightly decreased, and the thermal stability of gel strength was very good.
It is necessary to guarantee safe injectivity into the horizontal well by using gelants with a long gelation time. Both the near- and far-well formulas of gels must satisfy the gelation time of greater than 24 h for construction. The residual resistance factor of the gel used in the far well should not be too large (Frr < 50), and the residual resistance factor of the gel used in the near well should be higher than that of the far well (Frr < 200). According to practical experience and economic benefits, two kinds of formulas of polymer gels were selected: 0.30% HPAM + 0.3% PR and 0.1% Cr3+ cross-linker, as well as 0.45% HPAM + 0.5% PR and 0.15% Cr3+ cross-linker. Taking one formula of the polymer gel as an example, Figure 8 shows the gelation performance of the gel prepared via 0.30% HPAM + 0.30% PR and 0.1% Cr3+ after aging 3 days and 30 days. It can be seen that the gel has no syneresis even after aging for 30 days.
It can be seen from Table 5 that plugging efficiency was more than 98% for different formulas of gel systems. Moreover, with the increase in polymer and cross-linker concentration, both the plugging efficiency and residual resistance factor were improved. This indicates that the gel system has good plugging properties.

3.3. Creep Recovery Property

The creep recovery property of the gel is shown in Figure 9. The polymer gel good deformability, which easily leads to deep migration into water-yielding formation and water plugging for enhanced oil recovery. By analyzing the strain characteristics of the gel, the creep recovery process can be divided into two phases. In the first phase, the constant stress (2.4 Pa) acted on the gel samples for 120 s. The initial strain increased sharply and then tended to become stable over time. The connections between the main structural units in the elastic gels were stretched elastically, and the strain value was several times than that of initial state at the constant shear stress. In the second phase, the constant stress was removed from the gel samples, and the strain could be recovered. The metallic chromium cross-linked gel destroyed its viscoelasticity under shear stress. It can be concluded the deformation and recovery abilities of the gel prepared via HPAM + PR and Cr3+ cross-linker is strong, which means that the gel has strong deformability and good elasticity.

3.4. Microstructure of the Gel Systems

ESEM is a good way to accurately investigate the microstructure of the gel system. This method can keep the gel system from damage and observe the gel samples in their natural state. The ESEM micrograph of the gel sample is shown in Figure 10. It can be noted that the gel sample had a uniform three-dimensional network. Additionally, the pore size ranged from 5.0 μm to 28.0 μm, and the border thickness changed from 10.0 μm to 30.0 μm for the gel sample. A single chromium metal cross-linking agent forms a large network hole and a thin omentum [25,26], which is easy to dehydrate under external force damage. It can be concluded that the composite cross-linked gel has a more compact structure than that of metal cross-linked gels, which contributes to the good stability of the gel system.

3.5. Visual Model Experiment of Water-Coning Control in the Horizontal Well

As shown in Figure 11, the reservoir model with bottom water was placed vertically, and the middle point at top of the model was used to simulate the water coning point of the horizontal well. The vertical stripe was the water-channeling channel in the matrix model. The simulated oil (0.89 g/cm3, ~180 mPa·s) was injected from the water injection port at the bottom of the model to saturate the model, and then the water was injected after the crude oil aged and stabilized (Figure 11a). The simulated oil was produced from the top outlet in the model to mimic oil production from the horizontal well with bottom water (Figure 11b). As oil was produced from the top of the model, bottom-water coning would occur (Figure 11b). High-density brine has a higher density than plugging agent and higher viscosity than formation water, so it entered the bottom aquifer along the water coning channels. The brine had little effect on the performance of the following gel. The transitional density saline was injected into the well when the high-density saline was completed, and it separated the high-density saline and the polymer gel and weakened the effect of salt on gelant properties. The gelants entered the bottom aquifer along the water-coning channels and spread in a horizontal direction during their injection stage (Figure 11c). The displacement fluid displaced gelants in the vicinity of the oil–water interface (Figure 11d). Then, the top production port was shut in order to wait for the transformation of gelants into gels. The chemical gel packer can effectively solve horizontal bottom-water coning and increase oil production (Figure 11e).
From the experimental results in the above figure, it can be seen that the injection of high-density brine increased the density difference between the bottom water and oil. The gelants’ density ranged from 0.97 g/cm3 to 0.98 g/cm3, which is between high-density brine (ρ8%NaCl = 1.0255 g/cm3) and oil (ρo = 0.886 g/cm3). Thus, this chemical gel packer formed near the oil–water transition layer. When the chemical gel packer was completed to control bottom-water coning, it was difficult for the bottom water to flow into the horizontal well. The longer the gel packer stability was, the better the effect of controlling bottom-water coning was.

3.6. Field Application

3.6.1. Background of HX Well

The pay zone of the Y oil field is NgⅡ11+2, with a formation thickness of 8.4 m and a reservoir temperature of 55 °C. The depth of the HX well is 2045.0 m, and the horizontal section length is 382.0 m. The data of crude oil and liquids production in the HX well over time are presented in Figure 12. Due to a high water cut (>90%) in Mar 2015, measures were taken in the HX well to control excess water production using polymer gel in March 2016.
The main reasons for choosing a chemical gel packer are as follows: (1) The oil layer is thin (<10.0 m), and the horizontal well section is located lower and close to the oil–water interface; (2) there is no tight layer at the bottom of the oil layer to block bottom water; (3) the serious vertical heterogeneity of the reservoir is conducive to the gravity separation of injected fluid.

3.6.2. Gelants Formula (A + B) of Polymer Gel

(1)
Gelant A formula for far from wellbore
Gelant A were made up of 0.30% HPAM + 0.30% PR and 0.10% Cr3+ cross-linker, and the gelation time was 36 h at 55 °C;
(2)
Gelant B formula for near-wellbore zone
Gelant B were made up of 0.45% HPAM + 0.50% PR and 0.15% Cr3+ cross-linker, and the gelation time was 24 h at 55 °C.

3.6.3. Volume of Gelants

Equation (3) for calculating the volume of high-density brine is shown as follows:
V1 = 2 × (R1R2) × L × φ × β
where V1—the volume of high-density brine, m3; R1—radius of the brine layer, m; R2—radius of gelants layer, m; L—length of horizontal segment, m; φ—porosity, %; β—the ratio of the width of vertical high permeability to the length of horizontal segment [18].
For HX well, L = 382.0 m, φ = 30.4%. Assuming R1 = 12.0 m, R2 = 11.0 m and β = 20%, then volume of high-density brine as follows:
V1 = 2 × (12 − 11) × 382 × 30.4% × 20% = 47.0 m3
The designed V1 was 50 m3. The volume ratio of the high-density brine (8% NaCl) to transition density brine (4% NaCl) was 1:1, so each volume of them was 25.0 m3.
Equation (4) for calculating the volume of polymer gel is shown as follows:
V2 = 2 × (R2R3) × L × H × β × φ
where V2—the volume of polymer gel, m3; R2—radius of gelants, m; R3—radius of displacement fluid, m; L—length of horizontal section, m; φ—porosity, %; β1—the proportion of fluid channeling (≤5%).
If L = 382.0 m, φ = 30.4%, R2 = 11.0 m, R3 = 3.0 m and β1 = 3.1%, then volume of polymer gel as follows:
V2 = 2 × (11 − 3) × 382 × 8.4 × 30.4% × 3.1% = 500.0 m3
The designed V2 was 500.0 m3. The two gelants were divided into two parts according to the volume ratio of 3:2 (A:B), and the volume of gelant A for far from wellbore was 500.0 × 3/5 = 300.0 m3, while the volume of gelant B for the transition zone was 500 × 2/5 = 200.0 m3.
Equation (5) for calculating the volume of displacement fluid is shown as follows:
V3 = 2 × R3 × L × H × φ × K
where V3—volume of displacement fluid, m3. Then, volume of displacement fluid as follows:
V3 = 2 × 3 × 382 × 8.4 × 30.4% × 3.1% = 181.0 m3
The gelants’ density of the above gel formula was between 0.97 g/cm3 and 0.98 g/cm3, which is between high-density brine (ρ8%NaCl = 1.0255 g/cm3) and oil (ρo = 0.886 g/cm3). Therefore, the chemical packer formed by gel was easily built up near the oil–water interface.

3.6.4. Detail of Measurements

(1) The HX well maintained production for 10 days and restored the existing water cone channel; (2) briefly, 50.0 m3 high-density brine was injected into the HX well; (3) then, 300.0 m3 far-wellbore gelant was injected, after which 200.0 m3 near-wellbore gelant was injected into HX well; (4) then, 181.0 m3 displacement fluid was injected into HX well; (5) seawater was used as a displacement fluid to drive gelants into percolation water layer; (6) the HX well was shut in for 4 days, and the gelants became a chemical gel packer; (7) the HX well was reopened, and production resumed.

3.6.5. Field-Test Results

The data of crude oil and liquids production over time in HX well after treatment is shown in Figure 13. It can be seen that the highest total oil production per day of the HX well was 29.6 t, and the water cut decreased to 8% and remained at a lower level, less than 50% for a long time after the treatment in the HX well. Lastly, the accumulated oil production was 1.035 × 104 t instead of 3.9 × 103 t. Oil-field construction results confirmed that this novel method is quite suitable for water coning control and has a broad application prospect.

4. Conclusions

(1)
The designed gelant formula of soft movable polymer gel was 0.30~0.45% HPAM + 0.30~0.5% phenolic resin + 0.10~0.15% chromium acetate, with a corresponding gelation time of 26~34 h at 55 °C. The formula meets the technological requirements of controlling bottom-water coning in horizontal wells in offshore oil fields.
(2)
The visual glass plate simulation device can intuitively present the phenomenon of bottom-water coning and the effect of high-density brine injection and chemical packer control, which confirmed the feasibility of the process.
(3)
Combined with the production status and reservoir conditions of the HX well in the Y oil field, the technology of soft movable polymer gel for controlling water coning was successfully applied, which provides a technical basis for cost reduction and efficiency improvement in offshore oil fields.

Author Contributions

Data curation, Y.S.; funding acquisition, Q.Y.; investigation, G.Z.; methodology, Q.Y. and Y.L.; visualization, P.W.; writing—original draft preparation, J.Q.; writing—review and editing, Q.Y. and Y.L. All authors have read and agreed to the published version of the manuscript.

Funding

The authors sincerely appreciate the financial support from the National Natural Science Foundation of China (No. 52074249, 51874261) and Fundamental Research Funds for the Central Universities (2-9-2019-103).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data are contained within the article.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Machale, J.; Majumder, S.K.; Ghosh, P.; Sen, T.K. Development of a novel biosurfactant for enhanced oil recovery and its influence on the rheological properties of polymer. Fuel 2019, 257, 116067. [Google Scholar] [CrossRef]
  2. Liu, Y.; Zou, C.; Zhou, D.; Dai, C. Novel chemical flooding system based on dispersed particle gel coupling in-depth profile control and high efficient oil displacement. Energy Fuels 2019, 33, 3123–3132. [Google Scholar] [CrossRef]
  3. Dehaghani, A.; Badizad, M.H. Impact of ionic composition on modulating wetting preference of calcite surface: Implication for chemically tuned water flooding. Colloids Surfaces A 2019, 568, 470–480. [Google Scholar] [CrossRef]
  4. Wei, P.; Zheng, L.; Yang, M. Fuzzy-ball fluid self-selective profile control for enhanced oil recovery in heterogeneous reservoirs: The techniques and the mechanisms. Fuel 2020, 275, 117959. [Google Scholar] [CrossRef]
  5. Bai, Y.; Lian, Y.; Ban, C.; Wang, Z.; Zhao, J.; Zhang, H. Facile synthesis of temperature-resistant hydroxylated carbon black/polyacrylamide nanocomposite gel based on chemical crosslinking and its application in oilfield. J. Mol. Liq. 2021, 329, 115578. [Google Scholar] [CrossRef]
  6. Song, Z.; Bai, B.; Challa, R. Using Screen models to evaluate the injection characteristics of particle gels for water control. Energy Fuels 2018, 32, 352–359. [Google Scholar] [CrossRef]
  7. You, Q.; Zhao, F. Research and application of deep plugging water in oil well. Drill Prod. Technol. 2007, 30, 85–87. [Google Scholar]
  8. Bartosek, M.; Mennella, A.; Lockhart, T. Polymer gels for conformance treatments: Propagation on Cr (III) crosslinked complexes in porous media. In Proceedings of the SPE/DOE Symposium on Enhanced Oil Recovery, Tulsa, OK, USA, 17–20 April 1994. [Google Scholar]
  9. Seright, R.S.; Lane, R.H.; Sydansk, R.D. A strategy for attacking excess water production. SPE Prod. Facil. 2003, 18, 158–169. [Google Scholar] [CrossRef] [Green Version]
  10. Albonico, P.; Bartosek, M.; Malandrino, A. Studies on phenol-formaldehyde crosslinked polymer gels in bulk and in porous media. In Proceedings of the SPE International Symposium on Oilfield Chemistry, San Antonio, TX, USA, 14–17 February 1995. [Google Scholar]
  11. Reddy, B.R.; Eoff, L.; Dalrymple, E.D.; Black, K.; Brown, D.; Rietjens, M. A natural polymer-based cross-linker system for conformance gel systems. SPE J. 2003, 8, 99–106. [Google Scholar] [CrossRef]
  12. Zhao, F. Chemicals for Oil Recovery; China University of Petroleum Press: Dongying, China, 2001. [Google Scholar]
  13. Zhao, F. Principle of Enhanced Oil Recovery; China University of Petroleum Press: Dongying, China, 2006. [Google Scholar]
  14. Strelets, L.A.; Ilyin, S.O. Effect of enhanced oil recovery on the composition and rheological properties of heavy crude oil. J. Pet. Sci. Eng. 2021, 203, 108641. [Google Scholar] [CrossRef]
  15. Ilyin, S.O.; Strelets, L.A. Basic Fundamentals of Petroleum Rheology and Their Application for the Investigation of Crude Oils of Different Natures. Energy Fuels 2018, 32, 268–278. [Google Scholar] [CrossRef]
  16. Gorbacheva, S.N.; Ilyin, S.O. Morphology and rheology of heavy crude oil/water emulsions stabilized by microfibrillated cellulose. Energy Fuels 2021, 35, 6527–6540. [Google Scholar] [CrossRef]
  17. Amir, Z.; Saaid, I.; Junaidi, M.; Baker, W. Weakened PAM/PEI polymer gel for oilfield water control: Remedy with silica nanoparticles. Gels 2022, 8, 265. [Google Scholar] [CrossRef] [PubMed]
  18. Whitney, D.; Montgomery, D.; Hutchins, R. Water shutoff in the North sea: Testing a new polymer gel system in the heather field, UKCS Block 2/5. SPE Prod. Facil. 1996, 11, 108–112. [Google Scholar] [CrossRef]
  19. Sydansk, R.D. Acrylamide-polymer/chromium (III)-carboxylate gels for near wellbore matrix treatments. SPE Adv. Technol. Ser. 1993, 1, 146–152. [Google Scholar] [CrossRef]
  20. Southwell, G.P.; Posey, S.M. Applications and results of acrylamide-polymer/chrnmium (III) Carboxylate Gels. In Proceedings of the SPE 27779, SPE/DOE Improved Oil Recovery Symposium, Tulsa, OK, USA, 17–20 April 1994. [Google Scholar]
  21. Larry, E.; Eldon, D.; Don, M.; Julio, V. Worldwide field applications of a polymeric gel system for conformance applications. SPE Prod. Oper. 2007, 22, 231–235. [Google Scholar]
  22. Gino, D.; Phil, R. New insights into water control—A review of the state of the art. In Proceedings of the SPE77963, SPE Asia Pacific Oil and Gas Conference and Exhibition, Melbourne, Australia, 8–10 October 2002. [Google Scholar]
  23. Liu, J.; Li, L.; Sun, Y. Biomimetic functional hydrogel particles with enhanced adhesion characteristics for applications in fracture conformance control. J. Ind. Eng. Chem. 2022, 106, 482–491. [Google Scholar] [CrossRef]
  24. Zhao, G.; Dai, C.; You, Q. Characteristics and displacement mechanisms of the dispersed particle gel soft heterogeneous compound flooding system. Pet. Explor. Dev. 2018, 45, 464–473. [Google Scholar] [CrossRef]
  25. Jia, H.; Pu, W.; Zhao, J.; Liao, R. Experimental investigation of the novel phenol-formaldehyde cross-linking HPAM gel system: Based on the secondary cross-linking method of organic cross-linkers and its gelation performance study after flowing through porous media. Energy Fuels 2011, 25, 727–736. [Google Scholar] [CrossRef]
  26. Yang, H.; Iqbal, M.; Lashari, Z.; Kang, W. Experimental research on amphiphilic polymer/organic chromium gel for high salinity reservoirs. Colloids Surf. A: Physicochem. Eng. Asp. 2019, 582, 123900. [Google Scholar] [CrossRef]
  27. Zhu, D.; Bai, B.; Hou, J. Polymer gel systems for water management in high-temperature petroleum reservoirs: A chemical review. Energy Fuels 2017, 31, 13063–13087. [Google Scholar] [CrossRef]
  28. Pu, J.; Geng, J.; Han, P.; Bai, B. Preparation and salt-insensitive behavior study of swellable, Cr3+-embedded microgels for water management. J. Mol. Liq. 2019, 273, 551–558. [Google Scholar] [CrossRef]
  29. Zhang, W.; Yang, H.; Sarsenbekuly, B.; Zhang, M.; Aidarova, S. The advances of organic chromium based polymer gels and their application in improved oil recovery. Adv. Colloid Interface Sci. 2020, 282, 102214. [Google Scholar] [CrossRef] [PubMed]
  30. Sabhapondit, A.; Borthakur, A.; Haque, I. Water soluble acrylamidomethyl propane sulfonate (AMPS) copolymer as an enhanced oil recovery chemical. Energy Fuels 2003, 17, 683–688. [Google Scholar] [CrossRef]
  31. Sydansk, R.D.; Marathon Oil Co. A new conformance improvement treatment chromium(III) gel technology. In Proceedings of the SPE 17329 Presented at SPE Enhanced Oil Recovery Symposium, Tulsa, OK, USA, 17–20 April 1988. [Google Scholar]
  32. Liu, Y.; Dai, C.; Wang, K.; Zou, C.; Gao, M.; Fang, Y.; You, Q. Study on a novel cross-linked polymer gel strengthened with silica nanoparticles. Energy Fuel 2017, 31, 9152–9161. [Google Scholar] [CrossRef]
Figure 1. Flowchart of methodology.
Figure 1. Flowchart of methodology.
Gels 08 00352 g001
Figure 2. Schematic of the experimental set-up: 1—pump, 2—valve, 3—brine water container, 4—treatment fluid contianer, 5—pressure meter, 6—sand pack, and 7—graduated cylinder.
Figure 2. Schematic of the experimental set-up: 1—pump, 2—valve, 3—brine water container, 4—treatment fluid contianer, 5—pressure meter, 6—sand pack, and 7—graduated cylinder.
Gels 08 00352 g002
Figure 3. Schematic of visual physical simulation model: 1—computer, 2—video camera system, 3—syringe pump, and 4—model.
Figure 3. Schematic of visual physical simulation model: 1—computer, 2—video camera system, 3—syringe pump, and 4—model.
Gels 08 00352 g003
Figure 4. Schematic of polymer gel for controlling bottom-water coning in horizontal well: (a) reservoir with bottom water; (b) bottom water coning; (c) injecting high-density brine; (d) injecting the gelants; (e) injecting displacement fluid; (f) restarting well production: Gels 08 00352 i001 oil layer; Gels 08 00352 i002 aquifer; Gels 08 00352 i003 high-density brine; Gels 08 00352 i004 gelant; Gels 08 00352 i005 displacement fluid.
Figure 4. Schematic of polymer gel for controlling bottom-water coning in horizontal well: (a) reservoir with bottom water; (b) bottom water coning; (c) injecting high-density brine; (d) injecting the gelants; (e) injecting displacement fluid; (f) restarting well production: Gels 08 00352 i001 oil layer; Gels 08 00352 i002 aquifer; Gels 08 00352 i003 high-density brine; Gels 08 00352 i004 gelant; Gels 08 00352 i005 displacement fluid.
Gels 08 00352 g004
Figure 5. Density and viscosity of brine as a function of salt mass fraction at 55 °C.
Figure 5. Density and viscosity of brine as a function of salt mass fraction at 55 °C.
Gels 08 00352 g005
Figure 6. Histogram of gelation time (h) of 0.30% HPAM + PR and Cr3+ cross-linker.(The color represents gelation time of gel).
Figure 6. Histogram of gelation time (h) of 0.30% HPAM + PR and Cr3+ cross-linker.(The color represents gelation time of gel).
Gels 08 00352 g006
Figure 7. Histogram of gelation time (h) of 0.45% HPAM + PR and Cr3+ cross-linker. (The color represents gelation time of gel).
Figure 7. Histogram of gelation time (h) of 0.45% HPAM + PR and Cr3+ cross-linker. (The color represents gelation time of gel).
Gels 08 00352 g007
Figure 8. The gelation performance of gel prepared via PR and Cr3+ cross-linker after aging 3 d and 30 d, respectively.
Figure 8. The gelation performance of gel prepared via PR and Cr3+ cross-linker after aging 3 d and 30 d, respectively.
Gels 08 00352 g008
Figure 9. Elastic characteristics of the gel system at 55 °C.
Figure 9. Elastic characteristics of the gel system at 55 °C.
Gels 08 00352 g009
Figure 10. ESEM micrographs of the gel sample.
Figure 10. ESEM micrographs of the gel sample.
Gels 08 00352 g010
Figure 11. Visual physical simulation experiments: (a) horizontal well with bottom water; (b) bottom water coning; (c) injecting high-density brine and transition-density brine and injecting the gelants; (d) injecting displacement fluid; (e) resumption of production.
Figure 11. Visual physical simulation experiments: (a) horizontal well with bottom water; (b) bottom water coning; (c) injecting high-density brine and transition-density brine and injecting the gelants; (d) injecting displacement fluid; (e) resumption of production.
Gels 08 00352 g011aGels 08 00352 g011b
Figure 12. Data of crude oil and liquids production over time in HX well before treatment.
Figure 12. Data of crude oil and liquids production over time in HX well before treatment.
Gels 08 00352 g012
Figure 13. Data of crude oil and liquids production over time in HX well after treatment.
Figure 13. Data of crude oil and liquids production over time in HX well after treatment.
Gels 08 00352 g013
Table 1. Composition of Y oil-field formation water.
Table 1. Composition of Y oil-field formation water.
ComponentsNa+ and K+Ca2+Mg2+HCO3SO42Cl
Concentration (mg/L)10,516.2423.51524.6139.82821.618,752.5
Table 2. Gel strength ratings and descriptions [17].
Table 2. Gel strength ratings and descriptions [17].
CodeDetailed Gel Description
ANo detectable gel formed: gel has the same viscosity as the original polymer solution.
BHighly flowing gel: gel is slightly more viscous than the original polymer solution.
CFlowing gel: most of the gel flows to the vial/tube top upon inversion.
DModerately flowing gel: only a small portion (5~15%) of the gel does not readily flow to the vial/tube top upon inversion.
EBarely flowing gel: gel barely flows to the vial/tube top; a significant portion (>15%) of the gel does not flow upon inversion.
FHighly deformable nonflowing gel: gel does not quite reach the vial/tube top upon inversion.
GModerately deformable nonflowing gel: gel deforms about half the distance to the vial/tube top upon inversion.
HSlightly deformable nonflowing gel: gel surface slightly deforms upon inversion.
IRigid gel: no gel surface deformation occurs upon inversion.
JRinging rigid gel: a tuning fork-like mechanical vibration occurs upon tapping.
Table 3. Gel strength and long-term thermal stability of the gel system prepared via 0.30% HPAM + PR and Cr3+ cross-linker.
Table 3. Gel strength and long-term thermal stability of the gel system prepared via 0.30% HPAM + PR and Cr3+ cross-linker.
HPAM/%PR/%Cr3+/%Gel Strength/%Aging 30 d at
55 °C
0.300.300.05D~ENo syneresis
0.10FNo syneresis
0.15ENo syneresis
0.2ENo syneresis
0.400.05C~DNo syneresis
0.10FNo syneresis
0.15FNo syneresis
0.20E~FNo syneresis
0.500.05CNo syneresis
0.10FNo syneresis
0.15F~GNo syneresis
0.20FNo syneresis
0.600.05CNo syneresis
0.10E~FNo syneresis
0.15F~GNo syneresis
0.20F~GNo syneresis
Table 4. Gel strength and long-term thermal stability of the gel system prepared via 0.45% HPAM + PR and Cr3+ cross-linker.
Table 4. Gel strength and long-term thermal stability of the gel system prepared via 0.45% HPAM + PR and Cr3+ cross-linker.
HPAM/%PR/%Cr3+/%Gel Strength/%Aging 30 d at 55 °C
0.450.300.05FNo syneresis
0.10FNo syneresis
0.15F~GNo syneresis
0.2F~GNo syneresis
0.400.05D~ENo syneresis
0.100F~GNo syneresis
0.15F~GNo syneresis
0.20GNo syneresis
0.500.05CNo syneresis
0.10FNo syneresis
0.15G~HNo syneresis
0.20G~HNo syneresis
0.600.05CNo syneresis
0.10FNo syneresis
0.15G~HNo syneresis
0.20G~HNo syneresis
Table 5. Plugging capacity of the gel system.
Table 5. Plugging capacity of the gel system.
Gel TypeGel Formula (wt)Gelation Time/hInitial
Permeability/μm2
Plugging
Efficiency/%
Residual
Resistance Factor
HPAM + PR + Cr3+0.30% + 0.50% + 0.20%263.8999.85769.2
0.30% + 0.40% + 0.15%343.0999.16109.1
0.30% + 0.30% + 0.10%324.2496.9432.2
0.45% + 0.50% + 0.20%223.8799.65356.8
0.45% + 0.4% + 0.15%243.0898.7580.0
0.45% + 0.3% + 0.10%242.8395.7523.5
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Qu, J.; Wang, P.; You, Q.; Zhao, G.; Sun, Y.; Liu, Y. Soft Movable Polymer Gel for Controlling Water Coning of Horizontal Well in Offshore Heavy Oil Cold Production. Gels 2022, 8, 352. https://doi.org/10.3390/gels8060352

AMA Style

Qu J, Wang P, You Q, Zhao G, Sun Y, Liu Y. Soft Movable Polymer Gel for Controlling Water Coning of Horizontal Well in Offshore Heavy Oil Cold Production. Gels. 2022; 8(6):352. https://doi.org/10.3390/gels8060352

Chicago/Turabian Style

Qu, Jie, Pan Wang, Qing You, Guang Zhao, Yongpeng Sun, and Yifei Liu. 2022. "Soft Movable Polymer Gel for Controlling Water Coning of Horizontal Well in Offshore Heavy Oil Cold Production" Gels 8, no. 6: 352. https://doi.org/10.3390/gels8060352

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop