Next Article in Journal
Psychometric Evidence for Indirect Assessment of Child Abuse Risk in Child Welfare-Involved Mothers
Previous Article in Journal
Neonatal and Long-Term Prognosis of Monochorionic Diamniotic Pregnancies Complicated by Selective Growth Restriction
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Reply

Reply to Nyman, U.; Aspelin, P. Regarding Iodixanol for Pediatric CTA. Comment on “Pop, M. Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320. Children 2021, 8, 949”

1
ME1 Department, “George Emil Palade” University of Medicine Pharmacy Sciences and Technology of Tirgu Mures, 540142 Tirgu Mures, Romania
2
Radiology and Medical Imaging Department, Tirgu Mures Emergency Institute for Cardiovascular Diseases and Heart Transplant, 540136 Tirgu Mures, Romania
Children 2022, 9(5), 709; https://doi.org/10.3390/children9050709
Submission received: 7 February 2022 / Accepted: 22 February 2022 / Published: 12 May 2022
We greatly appreciate the letter by Nyman et al. [1] to our manuscript titled “Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320” [2] that describes our experience in using four different contrast agents in pediatric CT angiography for infants referred for aortic arch evaluation.
We agree that obtaining proper contrast enhancements in computed tomography the iodine delivery rate (IDR) is of particular importance, as demonstrated by the detailed studies mentioned [3,4].
Unfortunately, the retrospective nature of our study allowed us to compare images acquired using the Technical Recommendations of the Society for Cardiovascular CT [5] where only flow (mL/s) and volume recommendations were available. Moreover, we would like to note that there was no statistically significant difference between IDRs for different contrast agents.
Per methodology, data were tested for normality using the D’Agostino–Pearson test, with a one-way analysis of variance (ANOVA) or Kruskal–Wallis test used to verify differences between groups. Therefore, in the tables, either mean or median were being displayed. We acknowledge the fact that differences in cardiac output and presence of significant comorbidities are of importance, but unfortunately such data fall outside of the purpose of the study and we can only regret that we have no such data to increase the strength of our results.
We agree with the qualities that allowed iodixanol to be used with great success in patients with impaired kidney function and that it is used with excellent results in the general pediatric CT examinations, and that, as pointed out [1], osmolality is of particular importance in neonates and small children.
Numan et al. [1] correctly pointed out that data regarding the injection site and catheter being used are not available but, historically, a 24- or 26-gauge canula placed in the upper extremities can be used. We can confirm, however, that all examinations were performed using a room-temperature contrast agent; therefore, we postulated that the differences in enhancement might be due to differences in viscosity. This is recognized also by the American College of Radiology guidelines [6] stating that “If a rapid injection rate is desired through a small angiocatheter and if contrast medium viscosity is high, …, the desired injection flow rate may not be achieved”. We would like to thank our colleagues for the suggestion of using a low-viscosity Iodixanol 270, and we are currently working towards its local availability.
We hope that we have cleared any misunderstandings regarding the methodological side of the analysis. CT angiography in infants remains a challenging procedure, especially in patients with congenital cardiovascular diseases, with proper enhancement of the vessels representing a multivariable function.
We agree that we had available a limited sample and we are accepting that we do not know exactly why using similar acquisition and injection protocols with Iodixanol 320 provided up to 40% less enhancement of the large vessels when compared to the other contrast mediums we had available; however, in our opinion, more data and more comparative studies are required to properly establish the justification of its usage in infant CT angiography.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The author declares no conflict of interest.

References

  1. Nyman, U.; Aspelin, P. Regarding Iodixanol for Pediatric CTA. Comment on Pop, M. Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320. Children 2021, 8, 949. Children 2022, 9, 696. [Google Scholar] [CrossRef]
  2. Pop, M. Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320. Children 2021, 8, 949. [Google Scholar] [CrossRef] [PubMed]
  3. Awai, K.; Hiraishi, K.; Hori, S. Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight. Radiology 2004, 230, 142–150. [Google Scholar] [CrossRef] [PubMed]
  4. Suzuki, H.; Oshima, H.; Shiraki, N.; Ikeya, C.; Shibamoto, Y. Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta, portal vein and liver at multi-detector row CT: A randomized study. Eur Radiol. 2004, 14, 2099–2104. [Google Scholar] [CrossRef] [PubMed]
  5. Han, B.K.; Rigsby, C.K.; Leipsic, J.; Bardo, D.; Abbara, S.; Ghoshhajra, B.; Lesser, J.R.; Raman, S.V.; Crean, A.M.; Nicol, E.D.; et al. Society of Cardiovascular Computed Tomography; Society of Pediatric Radiology; North American Society of Cardiac Imaging. Computed Tomography Imaging in Patients with Congenital Heart Disease, Part 2: Technical Recommendations. An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT): Endorsed by the Society of Pediatric Radiology (SPR) and the North American Society of Cardiac Imaging (NASCI). J Cardiovasc. Comput. Tomogr. 2015, 9, 493–513. [Google Scholar] [PubMed]
  6. ACR Manual on Contrast Media 2020 ACR Committee on Drugs and Contrast Media. American College of Radiology. 2020. Available online: https://www.acr.org/-/media/ACR/Files/Clinical-Resources/Contrast_Media.pdf (accessed on 1 February 2022).
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Pop, M. Reply to Nyman, U.; Aspelin, P. Regarding Iodixanol for Pediatric CTA. Comment on “Pop, M. Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320. Children 2021, 8, 949”. Children 2022, 9, 709. https://doi.org/10.3390/children9050709

AMA Style

Pop M. Reply to Nyman, U.; Aspelin, P. Regarding Iodixanol for Pediatric CTA. Comment on “Pop, M. Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320. Children 2021, 8, 949”. Children. 2022; 9(5):709. https://doi.org/10.3390/children9050709

Chicago/Turabian Style

Pop, Marian. 2022. "Reply to Nyman, U.; Aspelin, P. Regarding Iodixanol for Pediatric CTA. Comment on “Pop, M. Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320. Children 2021, 8, 949”" Children 9, no. 5: 709. https://doi.org/10.3390/children9050709

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop