Next Article in Journal
Sr2Fe1.575Mo0.5O6-δ Promotes the Conversion of Methane to Ethylene and Ethane
Next Article in Special Issue
Membrane Fouling Diagnosis of Membrane Components Based on MOJS-ADBN
Previous Article in Journal
Analysis of the Composition of Bromide Anion Oxidation Products in Aqueous Solutions with Different pH via Rotating Ring-Disk Electrode Method
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

SVM and ANN Modelling Approach for the Optimization of Membrane Permeability of a Membrane Rotating Biological Contactor for Wastewater Treatment

by
Sharjeel Waqas
1,*,
Noorfidza Yub Harun
1,*,
Nonni Soraya Sambudi
2,
Ushtar Arshad
1,
Nik Abdul Hadi Md Nordin
1,
Muhammad Roil Bilad
3,
Anwar Ameen Hezam Saeed
1 and
Asher Ahmed Malik
1
1
Chemical Engineering Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar 32610, Perak, Malaysia
2
Department of Chemical Engineering, Universitas Pertamina, Simprug, Jakarta Selatan 12220, Indonesia
3
Faculty of Integrated Technologies, Universiti Brunei Darussalam, Gadong BE1410, Brunei
*
Authors to whom correspondence should be addressed.
Membranes 2022, 12(9), 821; https://doi.org/10.3390/membranes12090821
Submission received: 2 August 2022 / Revised: 15 August 2022 / Accepted: 17 August 2022 / Published: 23 August 2022

Abstract

:
Membrane fouling significantly hinders the widespread application of membrane technology. In the current study, a support vector machine (SVM) and artificial neural networks (ANN) modelling approach was adopted to optimize the membrane permeability in a novel membrane rotating biological contactor (MRBC). The MRBC utilizes the disk rotation mechanism to generate a shear rate at the membrane surface to scour off the foulants. The effect of operational parameters (disk rotational speed, hydraulic retention time (HRT), and sludge retention time (SRT)) was studied on the membrane permeability. ANN and SVM are machine learning algorithms that aim to predict the model based on the trained data sets. The implementation and efficacy of machine learning and statistical approaches have been demonstrated through real-time experimental results. Feed-forward ANN with the back-propagation algorithm and SVN regression models for various kernel functions were trained to augment the membrane permeability. An overall comparison of predictive models for the test data sets reveals the model’s significance. ANN modelling with 13 hidden layers gives the highest R2 value of >0.99, and the SVM model with the Bayesian optimizer approach results in R2 values higher than 0.99. The MRBC is a promising substitute for traditional suspended growth processes, which aligns with the stipulations of ecological evolution and environmentally friendly treatment.

Graphical Abstract

1. Introduction

The operational parameters influencing the functioning of the rotating biological contactor (RBC) bioreactor have extensively been reported [1,2,3]. Operational parameters include disk rotational speed, hydraulic retention time (HRT), sludge retention time (SRT), and carrier media type [4,5]. The selection and optimization of parameters strictly depend on the influent wastewater and effluent quality requirement. Disk rotational speed is an important parameter for acclimatizing the microorganisms and developing a full-grown biofilm to digest the organics and nutrients at the carrier surface. It is also responsible for maintaining sufficient dissolved oxygen (DO) levels inside the bioreactor to facilitate degradation [6,7,8]. The selection of SRT and loading rates relies on the wastewater strength and effluent requirements. A short SRT only facilitates carbon deduction, whereas a longer SRT results in increased sludge concentration, hindering oxygen transfer [9].
Almost 90% of the global wastewater is discharged into the mainstream without any treatment. Treating and recycling wastewater are essential for a sustainable environment and ecological atmosphere [10]. In recent years, membrane technology, in conjunction with biological treatment, has improved the effluent quality and removal efficiency [11,12].
RBC is a biological process that employs attached growth bacteria for wastewater treatment. Membrane-integrated RBC as post-treatment has shown great significance [11,13]. The performance of the RBC bioreactor depends on the operational parameters such as disk rotational speed, HRT, SRT, and microbial activity [14]. The DO is provided to the microorganism through disk rotation. Hence, disk rotational speed is an important parameter in controlling the DO levels and microbial community inside the bioreactor. The selection of appropriate loading rates (HRT and SRT) is important for optimizing the bioreactor function [15,16].
Membrane rotating biological contactor (MRBC)—a novel membrane-integrated RBC bioreactor—is a hybrid process in which a membrane is placed between two rotating disks to scour off the foulants through the generation of shear rate [17]. The disk rotation speed generates a shear rate near the membrane surface to control the fouling. Recent studies have revealed that higher HRT results in low hydraulic and organic loading rates and subsequently low viscosity and sludge concentration. A higher HRT and SRT can facilitate a higher conversion efficiency and, consequently, a higher membrane permeability [18,19,20].
In recent years, great emphasis has been given to the control of membrane fouling using artificial neural networks (ANN) and support vector machine (SVM) [21,22]. An effective way to dampen the membrane fouling is the optimization of operational parameters [23]. The ANN has been successfully applied in microfiltration/ultrafiltration to predict the system performance, the relationship of different operational parameters with membrane fouling, and the optimization of the membrane fabrication process [24,25]. Chakraborty et al. [26] predicted the membrane flux by optimizing process parameters using an ANN model for the chromium-containing aqueous solution. The predicted model is based on the Bayesian algorithm and consists of two hidden layers. The results of the ANN model are more precise than the conventional response surface methodology regression analysis. Soleimani et al. [27] studied the oily wastewater to control the membrane fouling using an ANN model. The process parameters (temperature, trans-membrane pressure, pH, and velocity) are optimized using a feed-forward ANN model with back-propagation. The predicted model results are in excellent agreement (R2 > 0.99) with the experimental and trained data. Rahmanian et al. [28] studied the UF treatment of wastewater by designing an ANN model. The operating parameters (pH, trans-membrane pressure, feed concentration, and electrolyte concentration) were optimized using a feed-forward ANN model. The predicted model results suggest applying ANN as an effective tool to predict complex non-linear relationships. SVM is an empirical model technique showing promising results for non-linear functions and limited data sets [29]. Meng et al. [29] applied SVM to analyze membrane fouling control and predicted complex filtration behaviors. Therefore, ANN and SVM have been applied to the current system to optimize operational parameters to generate a higher shear rate and reduce membrane fouling [30].
Disk rotational speed, HRT, and SRT are significant parameters influencing the performance of the MRBC bioreactor. The present study investigated the effect of disk rotational speed, HRT, and SRT on membrane permeability. The objective of the current study is to explore the biological performance of the RBC bioreactor treating domestic wastewater, focusing on the effect of disk rotational speed, HRT, and SRT. The focus of the study is the development of an ANN prediction model for membrane permeability. A feed-forward ANN model with back-propagation was used to predict and train the data sets for the operational parameters. This study also focuses on SVM modelling for the optimization of operating parameters. A comparison of ANN and SVM is also demonstrated through the assessment of R2 and various error functions.

2. Materials and Methods

2.1. Sludge Inoculation

The sludge for the bacteria cultivation was collected from the full-scale wastewater treatment plant. The sludge was allowed to acclimatize the biofilm atop the polyurethane form attached to the disks. The bioreactor was fed with constant flow wastewater during the acclimatization period. The physical observation of the biofilm was performed regularly to see any changes. The biological performance of the bioreactor was calculated after the biofilm acclimatization.

2.2. Wastewater Preparation

The synthetic wastewater for the experimentation was prepared by blending leftover food (1 g/L). The prepared wastewater was left to settle for 2 h to remove the insoluble impurities. Physical treatment of the synthetic wastewater was performed by filtering through a 0.45-micron filter paper. The stock solution was diluted to match the municipal wastewater concentration. The prepared wastewater was analyzed to determine the chemical oxygen demand (COD), total nitrogen (TN), ammonium, turbidity, pH, and nitrate, as shown in Table 1.

2.3. Bioreactor Set-up and Operation

The bioreactor was fabricated in-house from acrylic sheets, as shown in Figure 1. The feed wastewater tank consists of a 45 L capacity fitted with a mechanical stirrer to keep the concentration of the feed wastewater consistent. The bioreactor had 25 × 25 × 30 cm3 dimensions and had a working volume of 6.5 L fabricated from the acrylic sheets. The bioreactor was fitted with a stainless-steel shaft driven by a DC motor at variable speed (30–200 rpm). Five disks of 1 cm thickness and 18 cm diameter were attached to the stainless-steel shaft. The disks were covered on both sides with polyurethane foam for the inoculation of bacteria. The disks rotated inside the bioreactor at 40% disk submergence. The wastewater from the storage tank was fed continuously to the RBC bioreactor, and treated effluent was transferred to the settling tank. A mechanical stirrer continuously stirred the feed wastewater at 100 rpm to keep the concentration uniform.
For the biofilm acclimatization, the sludge was poured on the rotating disks, and the bioreactor was fed with a constant organic loading rate and HRT. No sludge was discharged during the acclimatization period. The carbonaceous bacteria acclimatize in 3–5 days, while nitrifying bacteria require 14–17 days. The biofilm was physically observed for any changes during the acclimatization period. After completing the first phase of the experiments, the bioreactor achieved a steady-state effluent concentration. After biofilm acclimatization, the system was investigated for the effect of disk rotational speed, HRT, and SRT on membrane permeability. The organic loading rates were kept constant throughout the experiments. The disk rotational speed was increased from 30 to 50 rpm with an interval increase of 5, while SRT was increased from 5 to 15 d with an interval increase of 2.5. The SRT was set by wasting a calculated amount of sludge from the bioreactor daily.

2.4. Machine Learning Modelling

Machine learning algorithms’ main goal is to fit the model to training data with the ultimate aim of successfully predicting unknown test data. Good training quality, on the other hand, does not necessarily correlate to consistent test results. Overfitting is a well-known example of this. Typically, an overfitted model has a modest training error but a large test error. The model has acquired an excessive number of undesirable precise information from the training data and does not fit the unknown test data. Overfitting may develop due to insufficient training processes and internal limitations, resulting in a more sensitive and complicated model. To solve the overfitting issue, an internal validation procedure called cross-validation is used [31,32].
The artificial neural network and support vector machines were used in this research to simulate the membrane permeability based on the combined influence of predictor variables, namely disk rotational speed, HRT, and SRT (Table 2). The process flow of the machine learning models employed in this study is shown in Figure 1. Following appropriate data collection, the modelling procedure was carried out using MATLAB 2020b. The trained model was chosen with the greatest accuracy achievable based on the root mean square error and R2.

2.5. Artificial Neural Network

Machine learning is the technology that is largely used for prediction modelling by several recent research in the field of engineering [33,34]. In regard to machine learning, ANN is specialized computational algorithms whose application is inspired by the human central nervous system. Multilayer feed-forward neural network (MLFNN) is the commonest type of ANN, extensively used in predictive modelling and analyses. It is a back-propagation learning algorithm that, in this study, is based on the Lavenberg–Marquardt model that uses the Guass–Newton approach. This typical MLFNN network consists of an input layer of neurons interconnected by weights to the succeeding hidden layers, where the input data is processed through an activation function. Finally, this processed information is transmitted to the output layer. An illustration of a typical neural network is shown in Figure 2. The number of hidden layers, the corresponding neurons, and activation functions are iteratively varied to obtain an optimized ANN model.

2.6. Support Vector Machine

SVM is a recent statistical machine learning technique based on an optimization algorithm invented by Wang et al. [35]. Initially, this method was only utilized for classification tasks. It has recently been developed to tackle regression problems [35]. It has been accepted as a successful strategy for QSPR investigations due to its simplicity in dealing with complicated non-linear problems, given that the outputs are real values rather than 1 or −1 [36]. This may be accomplished by mapping the non-linear characteristics of the experimental data x in a high dimensional domain with an equally efficient alternative loss function and then using linear regression in the feature space [37].
SVM is an algorithm that is based on the principles of machine learning. SVM is based on structural risk minimization (SRM), which reduces over-fitting and increases generalization by minimizing the learning model’s projected error [38]. SVM does not provide a pre-determined structure, since the training samples’ contributions judge the training data sets’ contributions. Only chosen data samples are used for the final model development, known as “support vectors.” Figure 3 depicts the modelling process and data shifting into a chosen dimensional space. The SVM uses the objective function presented in Equation (1).
min 1 2 w 2 + C i = 1 n ( ξ i + ξ i * )
Given,
( w ϕ ( x i ) + b ) y i ε + ξ i
y i ( w ϕ ( x i ) + b ) ε + ξ i *
where w represents the direction vector, and C denotes the adjustment factor, which is a trade-off between training error and the flatness of the model. ξ i * and ξ i are known as slack variables, and ϕ ( x i ) accounts for the higher dimensional hyperspace for the input vector x i .
There are two components to Equation (1). The first is the goal function, and the second compensates for the fitting error. To accomplish its goodness of fit, the SVM model employs the notion of minimizing of summation of errors. SVMs employ kernel functions to convert data from a lower-dimensional space to a higher-dimensional domain. The most often-utilized kernel functions are the radial basis function (RBF), linear, Gaussian, polynomial, and non-linear functions [31].

3. Results and Discussion

3.1. Artificial Neural Networks

The data are divided into three categories in the ANN modeling process: 70% training, 15% validation, and 15% testing. The MLFNN equipped with the Lavenberg–Marquardt algorithm adjusts the weights using back-propagation to reduce the error function value. This cycle is repeated until the error function reaches the minimal value and stabilizes; thus, the network is declared trained. MLFNN is not only simple but is faster in the training process and, at the same time, is capable of learning non-linear models in real-time. In this research, the sigmoid function “tansig” and the linear activation function “purlin” are used in the hidden and output layers. The “tansig” activation function is given in Equations (2) and (3) [39].
f ( x ) = e x e x e x + e x  
Given
  x j = i = 1 N w i j y i + b j  
where x in Equation (2) is the weighted sum of the inputs, which is calculated in terms of weights (w), biases (b), and output (y) according to Equation (3).
The most optimized network was obtained with one hidden layer containing 13 hidden neurons. The performance index R-squared given in Figure 4, and MSE values for the training testing and validation for the trained network are 0.99, 0.99, 0.99, and 0.26, 0.31, and 0.21, respectively. Error histogram and best validation performance are given in Figure 5. Figure 6 shows the comparison with training and testing performance using predictive permeability and actual permeability.

3.2. Support Vector Machine

The data in this research were separated into training and external validation/testing sets at a ratio of 85 percent and 15%, respectively. The cross-validation folds for training the SVM models were set to k-folds = 5. Three optimization techniques were used in the training process: Bayesian optimization, grid search, and random search. The hyperparameters were tuned throughout the training phase until acceptable results were achieved. Various kernel functions were tested in this research to see which was the best among them for developing a robust model. The cubic kernel function was found suitable with the best-optimized model, as shown in Equation (3) [40]. Figure 7, Figure 8 and Figure 9 show the training of SVMs with random search, Bayesian, and grid search optimizers, along with the training and testing results.
k ( x , y ) = [ ( x y ) + 1 ] 3
SVM has been applied to predict the membrane permeability for the operating parameters (disk rotational speed, HRT, and SRT). Previous studies also show that SVM has been applied to validate the effect of operating parameters, membrane properties, and filtrate characteristics on membrane fouling [41,42,43]. SVM modelling approach outperforms other models in terms of membrane resistance estimation in the membrane bioreactor [44]. The database of SVM training models can be used to predict the membrane fouling behavior for the unknown data sets. Thus, the non-linear relationship between the operational and output parameters (membrane fouling) results in efficient and powerful perdition SVM models compared to traditional empirical for the complex filtration processes.

3.3. Performance Comparison of Trained Models

The performance of the models developed through ANN and SVM were compared for the correlation coefficient (R2), RMSE, MBE, MAE, and NSE. The R2 value shows whether a linear relationship lies between the expected and observed membrane fouling values. RSME indicates the difference between the expected vs. calculated value. Table 3 shows the performance comparison of the trained modes through ANN and SVM for both the trained and unseen data sets. Table 3 shows that the ANN model with 13 nodes results in the best R2 value of 0.999 along with other error indexes for the trained data set. The R2 for the SVM Bayesian optimizer results in a 0.992 value, indicating superior performance compared to SVM grid search and SVM random search.

4. Conclusions

Membrane fouling dampens the application of membrane technology for wastewater treatment. The utilization of disk rotation to supply oxygen to microorganisms results in higher microbial activity and subsequently higher membrane permeability. The membrane placed in between two rotating disks results in a compact design with high removal efficiencies. In this study, the MRBC employs shear generation through disk rotation to reduce membrane fouling. The SVM and ANN modelling approach optimizes the operational parameters (disk rotational speed, HRT, and SRT). A higher value for HRT (18 h) and SRT (15 d) enables higher membrane fouling control. The SVM and ANN modelling results showed that all three operational parameters notably affect the membrane permeability. The SVM and ANN result in a higher R2 value (>0.99), indicating the model’s significance. The predictive model was tested for the unknown data sets, and the findings are in close agreement with the proposed model. The application of optimized and decentralized MRBC can result in a sustainable and cleaner environment.

Author Contributions

S.W. performed all the experiments and prepared the manuscript draft; M.R.B. and N.Y.H. contributed to the original idea of the study, conceptually design of the study, supervised the work and revised the manuscript; N.S.S., U.A., N.A.H.M.N., A.A.H.S. and A.A.M. revised the manuscript. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by International Collaborative Research Fund (UTP-UMS 2021) through grant number 015ME0-256.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

The authors acknowledge the support from Universiti Teknologi PETRONAS, Malaysia for providing the research and support facilities. The APC of this article was supported through grant number 015ME0-256.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Tabraiz, S.; Haydar, S.; Hussain, G. Evaluation of a cost-effective and energy-efficient disc material for rotating biological contactors (RBC), and performance evaluation under varying condition of RPM and submergence. Desalination Water Treat. 2016, 57, 20439–20446. [Google Scholar] [CrossRef]
  2. Waqas, S.; Harun, N.Y.; Bilad, M.R.; Samsuri, T.; Nordin, N.A.H.M.; Shamsuddin, N.; Nandiyanto, A.B.D.; Huda, N.; Roslan, J. Response Surface Methodology for Optimization of Rotating Biological Contactor Combined with External Membrane Filtration for Wastewater Treatment. Membranes 2022, 12, 271. [Google Scholar] [CrossRef]
  3. Waqas, S.; Bilad, M.R.; Man, Z.B. Performance and Energy Consumption Evaluation of Rotating Biological Contactor for Domestic Wastewater Treatment. Indones. J. Sci. Technol. 2021, 6, 101–112. [Google Scholar] [CrossRef]
  4. Mohammadi, M.; Mohammadi, P.; Karami, N.; Barzegar, A.; Annuar, M.S.M. Efficient hydrogen gas production from molasses in hybrid anaerobic-activated sludge-rotating biological contactor. Int. J. Hydrogen Energy 2019, 44, 2592–2602. [Google Scholar] [CrossRef]
  5. Hamedi, S.; Babaeipour, V.; Rouhi, M. Design, construction and optimization a flexible bench-scale rotating biological contactor (RBC) for enhanced production of bacterial cellulose by Acetobacter Xylinium. Bioprocess Biosyst. Eng. 2021, 44, 1071–1080. [Google Scholar]
  6. Li, N.; Zeng, W.; Yang, Y.; Wang, B.; Li, Z.; Peng, Y. Oxygen mass transfer and post-denitrification in a modified rotating drum biological contactor. Biochem. Eng. J. 2019, 144, 48–56. [Google Scholar] [CrossRef]
  7. Subhadarsini, L.; Dash, R.R. Treatment of Industrial Waste Water using Single-Stage Rotating Biological Contactor. In Proceedings of the IOP Conference Series: Materials Science and Engineering, Odisha, India, 17–18 September 2020; p. 012025. [Google Scholar]
  8. Waqas, S.; Bilad, M.R.; Aqsha, A.; Harun, N.Y.; Ayoub, M.; Wirzal, M.D.H.; Jaafar, J.; Mulyati, S.; Elma, M. Effect of membrane properties in a membrane rotating biological contactor for wastewater treatment. J. Environ. Chem. Eng. 2021, 9, 104869. [Google Scholar] [CrossRef]
  9. Delgado, N.; Navarro, A.; Marino, D.; Peñuela, G.; Ronco, A. Removal of pharmaceuticals and personal care products from domestic wastewater using rotating biological contactors. Int. J. Environ. Sci. Technol. 2019, 16, 1–10. [Google Scholar] [CrossRef]
  10. Petropoulos, E.; Yu, Y.; Tabraiz, S.; Yakubu, A.; Curtis, T.P.; Dolfing, J. High rate domestic wastewater treatment at 15° C using anaerobic reactors inoculated with cold-adapted sediments/soils–shaping robust methanogenic communities. Sci. Water Res. Technol. 2019, 5, 70–82. [Google Scholar] [CrossRef]
  11. Waqas, S.; Bilad, M.R. A review on rotating biological contactors. Indones. J. Sci. Technol. 2019, 4, 241–256. [Google Scholar] [CrossRef]
  12. Tabraiz, S.; Ahmad, S.; Shehzadi, I.; Asif, M.B. Study of physio-psychological effects on traffic wardens due to traffic noise pollution; exposure-effect relation. J. Environ. Health sci. 2015, 13, 1–8. [Google Scholar] [CrossRef] [Green Version]
  13. Irfan, M.; Waqas, S.; Arshad, U.; Khan, J.A.; Legutko, S.; Kruszelnicka, I.; Ginter-Kramarczyk, D.; Rahman, S.; Skrzypczak, A. Response Surface Methodology and Artificial Neural Network Modelling of Membrane Rotating Biological Contactors for Wastewater Treatment. Materials 2022, 15, 1932. [Google Scholar] [CrossRef]
  14. Irfan, M.; Waqas, S.; Khan, J.A.; Rahman, S.; Kruszelnicka, I.; Ginter-Kramarczyk, D.; Legutko, S.; Ochowiak, M.; Włodarczak, S.; Czernek, K. Effect of Operating Parameters and Energy Expenditure on the Biological Performance of Rotating Biological Contactor for Wastewater Treatment. Energies 2022, 15, 3523. [Google Scholar] [CrossRef]
  15. Waqas, S.; Bilad, M.R.; Man, Z.; Wibisono, Y.; Jaafar, J.; Mahlia, T.M.I.; Khan, A.L.; Aslam, M. Recent progress in integrated fixed-film activated sludge process for wastewater treatment: A review. J. Environ. Manag. 2020, 268, 110718. [Google Scholar] [CrossRef]
  16. Waqas, S.; Bilad, M.R.; Huda, N.; Harun, N.Y.; Md Nordin, N.A.H.; Shamsuddin, N.; Wibisono, Y.; Khan, A.L.; Roslan, J. Membrane Filtration as Post-Treatment of Rotating Biological Contactor for Wastewater Treatment. Sustainability 2021, 13, 7287. [Google Scholar]
  17. Waqas, S.; Bilad, M.R.; Man, Z.B.; Suleman, H.; Nordin, N.A.H.; Jaafar, J.; Othman, M.H.D.; Elma, M. An energy-efficient membrane rotating biological contactor for wastewater treatment. J. Cleaner Prod. 2021, 282, 124544. [Google Scholar] [CrossRef]
  18. Waqas, S.; Bilad, M.R.; Man, Z.B.; Klaysom, C.; Jaafar, J.; Khan, A.L. An integrated rotating biological contactor and membrane separation process for domestic wastewater treatment. Alexandria Eng. J. 2020, 59, 4257–4265. [Google Scholar] [CrossRef]
  19. Waqas, S.; Bilad, M.R.; Man, Z.B. Effect of organic and nitrogen loading rate in a rotating biological contactor for wastewater treatment. J. Phys. Conf. Ser. 2021, 1793, 012063. [Google Scholar] [CrossRef]
  20. Tabraiz, S.; Shamurad, B.; Petropoulos, E.; Quintela-Baluja, M.; Charlton, A.; Dolfing, J.; Sallis, P.J. Mitigation of membrane biofouling in membrane bioreactor treating sewage by novel quorum quenching strain of Acinetobacter originating from a full-scale membrane bioreactor. Bioresour. Technol. 2021, 334, 125242. [Google Scholar] [CrossRef]
  21. Corbatón-Báguena, M.-J.; Vincent-Vela, M.-C.; Gozálvez-Zafrilla, J.-M.; Álvarez-Blanco, S.; Lora-García, J.; Catalán-Martínez, D. Comparison between artificial neural networks and Hermia’s models to assess ultrafiltration performance. Sep. Purif. Technol. 2016, 170, 434–444. [Google Scholar] [CrossRef] [Green Version]
  22. Mirbagheri, S.A.; Bagheri, M.; Bagheri, Z.; Kamarkhani, A.M. Evaluation and prediction of membrane fouling in a submerged membrane bioreactor with simultaneous upward and downward aeration using artificial neural network-genetic algorithm. Process Saf. Environ. Prot. 2015, 96, 111–124. [Google Scholar] [CrossRef]
  23. Zhao, Z.; Lou, Y.; Chen, Y.; Lin, H.; Li, R.; Yu, G. Prediction of interfacial interactions related with membrane fouling in a membrane bioreactor based on radial basis function artificial neural network (ANN). Bioresour. Technol. 2019, 282, 262–268. [Google Scholar] [CrossRef]
  24. Schmitt, F.; Banu, R.; Yeom, I.-T.; Do, K.-U. Development of artificial neural networks to predict membrane fouling in an anoxic-aerobic membrane bioreactor treating domestic wastewater. Biochem. Eng. J. 2018, 133, 47–58. [Google Scholar] [CrossRef]
  25. Chew, C.M.; Aroua, M.K.; Hussain, M.A. Advanced process control for ultrafiltration membrane water treatment system. J. Cleaner Prod. 2018, 179, 63–80. [Google Scholar] [CrossRef]
  26. Chakraborty, S.; Dasgupta, J.; Farooq, U.; Sikder, J.; Drioli, E.; Curcio, S. Experimental analysis, modeling and optimization of chromium (VI) removal from aqueous solutions by polymer-enhanced ultrafiltration. J. Membr. Sci. 2014, 456, 139–154. [Google Scholar] [CrossRef]
  27. Soleimani, R.; Shoushtari, N.A.; Mirza, B.; Salahi, A. Experimental investigation, modeling and optimization of membrane separation using artificial neural network and multi-objective optimization using genetic algorithm. Chem. Eng. Res. Des. 2013, 91, 883–903. [Google Scholar] [CrossRef]
  28. Rahmanian, B.; Pakizeh, M.; Mansoori, S.A.A.; Abedini, R. Application of experimental design approach and artificial neural network (ANN) for the determination of potential micellar-enhanced ultrafiltration process. J. Hazard. Mater. 2011, 187, 67–74. [Google Scholar] [CrossRef]
  29. Meng, X.; Wang, F.; Meng, S.; Wang, R.; Mao, Z.; Li, Y.; Yu, M.; Wang, X.; Zhao, Q.; Yang, L. Novel Surrogates for Membrane Fouling and the Application of Support Vector Machine in Analyzing Fouling Mechanism. Membranes 2021, 11, 990. [Google Scholar] [CrossRef]
  30. Bagheri, M.; Akbari, A.; Mirbagheri, S.A. Advanced control of membrane fouling in filtration systems using artificial intelligence and machine learning techniques: A critical review. Process Saf. Environ. Prot. 2019, 123, 229–252. [Google Scholar] [CrossRef]
  31. Zhou, T.; Wang, F.; Yang, Z. Comparative analysis of ANN and SVM models combined with wavelet preprocess for groundwater depth prediction. Water 2017, 9, 781. [Google Scholar] [CrossRef] [Green Version]
  32. Arshad, U.; Taqvi, S.A.A.; Buang, A. Experimental analysis and data-driven machine learning modelling of the minimum ignition temperature (MIT) of aluminium dust. Fuel 2022, 324, 124569. [Google Scholar] [CrossRef]
  33. Arshad, U.; Taqvi, S.A.A.; Buang, A.; Awad, A. SVM, ANN, and PSF modelling approaches for prediction of iron dust minimum ignition temperature (MIT) based on the synergistic effect of dispersion pressure and concentration. Process Saf. Environ. Prot. 2021, 152, 375–390. [Google Scholar] [CrossRef]
  34. Arshad, U.; Taqvi, S.A.A.; Buang, A. Modelling of the minimum ignition temperature (MIT) of corn dust using statistical analysis and artificial neural networks based on the synergistic effect of concentration and dispersion pressure. Process Saf. Environ. Prot. 2021, 147, 742–755. [Google Scholar] [CrossRef]
  35. Wang, B.; Zhou, L.; Xu, K.; Wang, Q. Prediction of minimum ignition energy from molecular structure using quantitative structure–property relationship (QSPR) models. Ind. Eng. Chem. Res. 2017, 56, 47–51. [Google Scholar] [CrossRef]
  36. Safavi, H.R.; Esmikhani, M. Conjunctive use of surface water and groundwater: Application of support vector machines (SVMs) and genetic algorithms. Water Resour. Manag. 2013, 27, 2623–2644. [Google Scholar] [CrossRef]
  37. Bafitlhile, T.M.; Li, Z. Applicability of ε-Support Vector Machine and Artificial Neural Network for Flood Forecasting in Humid, Semi-Humid and Semi-Arid Basins in China. Water 2019, 11, 85. [Google Scholar] [CrossRef] [Green Version]
  38. Wu, M.-C.; Lin, G.-F. An hourly streamflow forecasting model coupled with an enforced learning strategy. Water 2015, 7, 5876–5895. [Google Scholar] [CrossRef] [Green Version]
  39. Nabipour, M.; Keshavarz, P. Modélisation de la tension superficielle de frigorigènes purs au moyen de réseaux neuronaux à rétropropagation non récurrents. Int. J. Refrig 2017, 75, 217–227. [Google Scholar] [CrossRef]
  40. Rustam, Z.; Arfiani, A.; Pandelaki, J. Cerebral infarction classification using multiple support vector machine with information gain feature selection. Bull. Electr. Eng. Inform. 2020, 9, 1578–1584. [Google Scholar] [CrossRef]
  41. Meng, X.; Meng, S.; Liu, Y. The Limitations in Current Studies of Organic Fouling and Future Prospects. Membranes 2021, 11, 922. [Google Scholar] [CrossRef]
  42. Hamedi, H.; Ehteshami, M.; Mirbagheri, S.A.; Zendehboudi, S. New deterministic tools to systematically investigate fouling occurrence in membrane bioreactors. Chem. Eng. Res. Des. 2019, 144, 334–353. [Google Scholar] [CrossRef]
  43. Cai, Y.-D.; Ricardo, P.-W.; Jen, C.-H.; Chou, K.-C. Application of SVM to predict membrane protein types. J. Theor. Biol. 2004, 226, 373–376. [Google Scholar] [CrossRef] [Green Version]
  44. Li, M.; Wei, D.; Liu, T.; Liu, Y.; Yan, L.; Wei, Q.; Du, B.; Xu, W. EDTA functionalized magnetic biochar for Pb (II) removal: Adsorption performance, mechanism and SVM model prediction. Sep. Purif. Technol. 2019, 227, 115696. [Google Scholar] [CrossRef]
Figure 1. Schematic diagram of RBC-ME configuration.
Figure 1. Schematic diagram of RBC-ME configuration.
Membranes 12 00821 g001
Figure 2. Process flow of artificial neural network and support vector machine.
Figure 2. Process flow of artificial neural network and support vector machine.
Membranes 12 00821 g002
Figure 3. Support vector regression for non-linear response modelling from (a) higher dimensional domain to (b) lower dimensional domain.
Figure 3. Support vector regression for non-linear response modelling from (a) higher dimensional domain to (b) lower dimensional domain.
Membranes 12 00821 g003
Figure 4. R2 values for trained artificial neural networks.
Figure 4. R2 values for trained artificial neural networks.
Membranes 12 00821 g004
Figure 5. (a) Training performance and (b) error histogram of the trained network.
Figure 5. (a) Training performance and (b) error histogram of the trained network.
Membranes 12 00821 g005
Figure 6. Actual vs. predicted permeability by ANN.
Figure 6. Actual vs. predicted permeability by ANN.
Membranes 12 00821 g006
Figure 7. (a) Experimental vs. predicted membrane permeability and (b) training of SVM using random search optimization.
Figure 7. (a) Experimental vs. predicted membrane permeability and (b) training of SVM using random search optimization.
Membranes 12 00821 g007
Figure 8. (a) Experimental vs. predicted membrane permeability and (b) training of SVM using Bayesian optimization.
Figure 8. (a) Experimental vs. predicted membrane permeability and (b) training of SVM using Bayesian optimization.
Membranes 12 00821 g008
Figure 9. (a) Experimental vs. predicted membrane permeability and (b) training of SVM using grid search optimization.
Figure 9. (a) Experimental vs. predicted membrane permeability and (b) training of SVM using grid search optimization.
Membranes 12 00821 g009
Table 1. Influent wastewater characteristics.
Table 1. Influent wastewater characteristics.
ContaminantInfluent
COD (mg/L)281 ± 8.5
TN (mg/L)2.5 ± 0.19
Ammonia (mg/L)0.66 ± 0.03
Nitrate (mg/L)0.49 ± 0.04
Turbidity (NTU)14.6 ± 0.55
pH6.28 ± 0.21
COD: chemical oxygen demand, TN: total nitrogen.
Table 2. Experimental Data for the Model Development.
Table 2. Experimental Data for the Model Development.
Run #Sr #(A) Disk Rotational Speed
(rpm)
(B) HRT
(h)
(C) SRT
(d)
Permeability (L/m2 h bar)
491401510296
162501215275
25323.21510245
344402010302
8530185272
516401510296
437401510295
188501215274
449401510296.5
3310409.9510291
51150125269
3612402010303
381340151.6286
3514402010302
101550185277
1916301815278
4817401510296
4118401518.4304
391940151.6286
1420301215270
302156.81510245
4722401510295
2423501815281
2324501815280.5
282556.81510244
92630185272
5327401510296.5
112850185276.5
12930125268
263023.21510244.5
3231409.9510291.5
63250125270
2033301815279
4634401510297
1535301215271
5536401510296
5037401510296.5
2238501815280
43950125269.5
34030125268.5
24130125268
4542401510296
1743501215274.5
4244401518.4304.5
294556.81510245.5
124650185275
4047401518.4304
5448401510296
3149409.9510291
275023.21510245
1351301215271
375240151.6286.5
5253401510295.5
2154301815280
75530185272
Table 3. Performance comparison of trained models.
Table 3. Performance comparison of trained models.
Error IndexANN 13SVM Bayesian OptimizerSVM Grid SearchSVM Random Search
Train
Data
Unseen DataTrain
Data
Unseen DataTrain
Data
Unseen DataTrain
Data
Unseen Data
RMSE0.5145.802.1416.0142.3435.8831.8036.602
MBE0.0441.636−0.152−0.75−0.013−0.580.258−0.284
MAE0.3673.7724.1242.1894.151.6184.456
NSE0.9990.7130.9840.70.9810.7060.9890.63
R20.9990.740.9920.7980.9830.7930.9890.805
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Waqas, S.; Harun, N.Y.; Sambudi, N.S.; Arshad, U.; Nordin, N.A.H.M.; Bilad, M.R.; Saeed, A.A.H.; Malik, A.A. SVM and ANN Modelling Approach for the Optimization of Membrane Permeability of a Membrane Rotating Biological Contactor for Wastewater Treatment. Membranes 2022, 12, 821. https://doi.org/10.3390/membranes12090821

AMA Style

Waqas S, Harun NY, Sambudi NS, Arshad U, Nordin NAHM, Bilad MR, Saeed AAH, Malik AA. SVM and ANN Modelling Approach for the Optimization of Membrane Permeability of a Membrane Rotating Biological Contactor for Wastewater Treatment. Membranes. 2022; 12(9):821. https://doi.org/10.3390/membranes12090821

Chicago/Turabian Style

Waqas, Sharjeel, Noorfidza Yub Harun, Nonni Soraya Sambudi, Ushtar Arshad, Nik Abdul Hadi Md Nordin, Muhammad Roil Bilad, Anwar Ameen Hezam Saeed, and Asher Ahmed Malik. 2022. "SVM and ANN Modelling Approach for the Optimization of Membrane Permeability of a Membrane Rotating Biological Contactor for Wastewater Treatment" Membranes 12, no. 9: 821. https://doi.org/10.3390/membranes12090821

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop