Next Article in Journal
Tissue-Engineered Vascular Graft with Co-Culture of Smooth Muscle Cells and Human Endothelial Vein Cells on an Electrospun Poly(lactic-co-glycolic acid) Microtube Array Membrane
Next Article in Special Issue
Reuse of Water in Laundry Applications with Micro- and Ultrafiltration Ceramic Membrane
Previous Article in Journal
Response Surface Methodology for Boron Removal by Donnan Dialysis: Doehlert Experimental Design
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Impact of Chlorinated-Assisted Backwash and Air Backwash on Ultrafiltration Fouling Management for Urban Wastewater Tertiary Treatment

1
Laboratoire de Mécanique, Modélisation et Procédés Propres, Equipe Procédés Membranaire (EPM-M2P2-CNRS-UMR 7340), Aix-Marseille Univ., Europôle de l’Arbois, BP 80, Bat. Laennec, Hall C, CEDEX 04, 13545 Aix-en-Provence, France
2
Société des Eaux de Marseille Métropole, 25 Rue Edouard Delanglade, BP 29, CEDEX 06, 13006 Marseille, France
*
Author to whom correspondence should be addressed.
Membranes 2021, 11(10), 733; https://doi.org/10.3390/membranes11100733
Submission received: 14 August 2021 / Revised: 22 September 2021 / Accepted: 22 September 2021 / Published: 27 September 2021
(This article belongs to the Special Issue Troubleshooting of Membrane Processes in Real Operation)

Abstract

:
To improve membrane fouling management, the NaClO-assisted backwash has been developed to improve permeability maintenance and reduce the need for intensive chemical cleanings. This study is aimed to focus on the efficiency of NaClO-assisted backwash in real UF pilot scale and with periodic classic backwash (CB) and air backwash (AB). The impacts on hydraulic filtration performance, physicochemical properties of membrane material under different addition frequencies of NaClO, and the performance of chlorinated CB and AB will be discussed. In result, 10 mg Cl2 L−1 NaClO addition in backwash water is confirmed to greatly improve the overall filtration performance and backwash cleaning efficiency. One condition stands out from the other due to better control of irreversible fouling, less NaClO consumption in 10 years prediction, sustainable and adaptable filtration performance, and less potential damage on the physicochemical properties of the membrane. Additionally, it can be inferred from this experiment that frequent contact with NaClO induced some degradation on the PES-made UF membrane surface properties. To retain the best state of UF membrane on anti-fouling and qualified production, the optimized condition with more frequent NaClO contact was not suggested for long-term filtration.

1. Introduction

Over the last decades, the application of membrane technology on wastewater treatment has expanded rapidly under increasing stringent legislation and environmental protection requirements [1]. Particularly, ultrafiltration (UF) as tertiary wastewater treatment technology has been accepted broadly for non-potable wastewater reuse [2]. During filtration, while the optimization of UF operating parameters can control membrane fouling, membrane cleaning is fundamental for fouling removal. Physical backwashes and chemical cleanings are the commonly used methods to remove membrane fouling. Physical backwashes, such as classic backwash (CB) or air backwash (AB), alternates the shear forces on the membrane surface by air scouring, air injection, or water backflush, in order to loosen and dislodge the deposits [3]. However, physical backwash is mostly powerless on irreversible fouling removal during long-term filtration, and the residual foulants after backwashes would be recompressed after multi-cycle filtration [4]. The conventional chemical cleaning plays an important role on irreversible fouling separation by chemical reagents soaking/reacting with membrane fouling which can damage the foulant–foulant and membrane–foulant interactions [5]. However, using high concentrated acids, soda, and/or oxidants/disinfectants and longer soaking time will gradually cause irreversible damages on membrane properties and filtration performances in long-term operation [3,6,7]. In this case, a novel chemically assisted maintenance backwash (CAMB), the combined physical backwash with lower concentrated oxidants/disinfectants (compared to chemical cleaning) in backwash water, has recently been developed for permeability maintenance improvement, so as to reduce the need for intensive chemical cleanings [8,9].
Sodium hypochlorite (NaClO), unproperly often called “chlorine”, is one of the commonly used oxidants/disinfectants, which can inactivate the microorganisms and oxidize the organic foulants to be more hydrophilic and easier to detach from the membrane surfaces [10,11,12]. Studies have also found that the presence of ClO is effective in terms of extracellular polymeric substances (EPS) disruption and microbial cell damage [13]. Researchers usually use the concentration of total chlorine or free chlorine to illustrate the quantity of chlorine they add in solutions [14]. In this study, the commonly mentioned chlorine concentration refers to total concentration unless otherwise specified as free chlorine. NaClO is an oxidant which is unstable under atmosphere with high temperature, light, strong acid, or other reductants. NaClO is also a strong base and weak acid salt that can hydrolyze and produce HOCl, NaOCl + H2O → Na+ + HOCl + OH. The microbicidal activity of chlorine is largely attributed to undissociated HOCl. The dissociation of HOCI to the less microbicidal form (OCl) depends on pH. The disinfecting efficacy of chlorine decreases with increasing pH, which is parallel to the conversion of undissociated HOCI to OCl [15,16]. Fukuzaki et al. [17] reported the bactericidal activity of 2.38 mg Cl2·L−1 (free chlorine) NaClO was increased with pH decreasing from 9.3 to 5.7 because the HOCl amount was increased from 13% (pH 9.3) to 98% (pH 5.7). In conventional chemical cleanings, NaClO is usually used at high levels (300–3000 mg NaClO·L−1/286–2860 mg Cl2·L−1) and in long time soaking for powerful membrane permeability recovery and irreversible fouling removal [8,18,19]. However, a high dosage of NaClO will accelerate the adverse effects on membrane properties and performance [19], by-products formation, and higher operating costs [9,20]. If it is in membrane bioreactor (MBR), the high level use of NaClO will inevitably suppress the microbial proliferation and the formation of sludge flocs [21,22]. Normally, the accumulated amount of NaClO in contact with membranes can be expressed as a total dose calculated in total chlorine concentration multiplied by contact time (CT) which can provide reference for the degradation progress of membranes. Hanafi et al. reported HClO and ·OH are the responsible species for the chain scission of polysulfone, polyamide, and polyethersulfone (PES) membranes [23,24,25,26]. Therefore, the accumulated amount of NaClO in membranes can cause degradation of membrane materials and membrane aging. PES membranes are considered highly tolerant to oxidants [27]. Wienk et al. [28] detected the aging of PES/PVP membrane under exposure to 6000 ppm/day of NaClO (approximately equal to 5718 mg Cl2·L−1·day). Yadav et al. [29] observed the PES membrane surface damage under exposure to 10,000–25,000 ppm/day of NaClO (approximately equal to 9530–23,853 mg Cl2·L−1·day), and the damage became worse with increasing amount of NaClO under the same conditions (temperature, pH, etc.). While ultrafiltration is mechanically and chemically stressed, the combined oxidant with physical backwash may accelerate physical damage and/or chemical degradation of membrane materials [30].
According to Fukuzaki et al. [31], low concentrations of OCl could destruct the exoplasmic organic matrix, while high concentrations of OCl led to diffusions of OCl into cells and disruption of cell metabolisms. Therefore, the new chemically assisted maintenance backwash first proposed by Wang et al. [8] with low dose of chlorinated disinfectants was developed and investigated on membrane cleaning efficiency. The effectiveness of the combined backwash with low dosage (<286 mg Cl2·L−1) of NaClO on membrane fouling removal has been mentioned in several publications (Table 1). Some studies added low level of NaClO into backwash water for disinfection but without special research on the impact of NaClO addition on cleaning efficiency, such as Wang et al. [32], and Liu et al. [33]. In 2001, Decarolis et al. [34] demonstrated that backwashing with chlorine addition (23.8 mg Cl2 L−1) significantly improved UF membrane productivity. Afterwards, Wang et al. [8] investigated the impacts of NaClO-assisted backwash on the hydraulic filtration performances of a membrane bioreactor (MBR) under different NaClO loads. Yue et al. [9] did a similar study scheme as Wang et al. [8] but with a different bioreactor, which was an anaerobic ceramic membrane bioreactor. In result, they both confirmed that backwash with a low level of NaClO enhanced the organic foulant degradation and inhibited microbial regrowth on membranes. Wang et al. [8] also mentioned that the NaClO-assisted backwash at lower NaClO concentrations and higher backflush frequencies made less adverse effects on the functional groups of the active layer of the membranes. Furthermore, Zhang et al. [35] stated that 100 mg·L−1 NaClO solution exhibited the best performance in removing the irreversible fouling resistance (88.4% ± 1.1%) from the algal-fouled UF membrane, compared to the solutions with 500 mg·L−1 NaOH, 500 mg·L−1 HCl and 150 mg·L−1 ethylenediaminetetraacetic acid. This might be attributed to the fact that NaClO could eliminate major foulants such as carbohydrate-like and protein-like materials on the membrane surface. In result, the cases in Table 1 confirmed the cleaning effectiveness of disinfectants (mostly NaClO) addition in backwash, but their concentrations varied under different conditions.
The membrane foulants in municipal secondary effluent include organic fouling, inorganic fouling, and microbial fouling [3,36,37]. Organic fouling is the main cause of irreversible fouling for membranes. Nonetheless, the efficiency and practicality of NaClO-assisted backwash has not been studied in real UF pilot scale and even less with periodic classic backwash (CB) and air backwash (AB). Therefore, this study aims to investigate the influence of NaClO-assisted CB and/or AB on the hydraulic filtration performance and fouling management in a UF pilot plant with maximum flow rate of 20 m3·d−1. Additionally, the impacts on physicochemical properties of membrane material under different addition frequencies of NaClO and the performance of chlorinated CB and AB will also be discussed

2. Materials and Methods

2.1. Semi-Industrial UF Pilot Plant

The semi-industrial UF pilot plant is automatically controlled and has a nominal capacity of 20 m3·d−1 [39]. Figure 1 shows the flow diagram of the pilot plant with filtration route and backwash routes. The feed water is the secondary effluent of a municipal wastewater treatment plant (WWTP) located in Châteauneuf-les-Martigues, France. The WWTP uses a conventional activated sludge process to treat raw wastewater. T1 and T2 are the tanks for permeate. Tank T1 contains permeate with chlorine in constant concentration. The chlorine concentration is controlled by the cooperation of control system and the chlorine meter. T2 is the permeate tank connected to the outside without chlorine used both as water production and backwash water. A 130 μm disk prefilter is used to avoid clogging of the hollow fibers. To control the filtration conditions and detect the filtration performance, pressure, temperature, chlorine and turbidity sensors of feed, pH sensor of effluent, and flowmeters are all connected to the data logger. The chlorine probe is a Dulcotest Type CGE 2-mA-10 ppm (ppm: parts per million, equivalent to mg·L−1 in water) from ProMinent (Dosiertechnik GmbH, Heidelberg, Germany) measuring free chlorine and organically bound chlorine (to cyanuric acid in the form of trichloroisocyanuric acid or sodium dichloroisocyanurate-bound chlorine). Each parameter is recorded every minute.
The membrane module is an ALTEONTM I (Aquasource, Toulouse, France) multichannel hollow fiber UF module. The detailed information of the UF module is shown in Table 2. PES membrane is blended with polyvinylpyrrolidone (PVP) additives to increase the hydrophilicity for anti-fouling [23]. PES membranes are considered highly tolerant to oxidants (>250,000 mg Cl2 L−1 h) and to a wide pH range between 2 and 12 [27]. It is operated in dead-end filtration mode with an inside-out configuration. The operational transmembrane pressure (TMP) on UF is better to be controlled under 1 bar. The hydraulic resistance of new membrane module was measured with pure water to be 4 × 1011 m−1 at 20 °C (pure water permeability = 900 L·m−2·h−1·bar−1). The maximum permeability of UF membrane when filtrated with the feed water after deep chemical cleaning is around 650 L·m−2·h−1·bar−1 at 20 °C. Therefore, each filtration condition was started from initial Lp at around 650 L·m−2·h−1·bar−1, and the corresponding membrane resistance of 5.51 × 1011 m−1 at 20 °C was taken into account for future calculations.
The feed water quality is shown in Table 3, and the UF feed water contains bacteria, virus, organic matter and suspended solids.

2.2. Membrane Cleaning

Two modes of physical backwashes during filtration are classical backwashes (CB) and air backwashes (AB). A cleaning of CB includes 4 steps: top backwash, bottom backwash, both heads backwash, and prefilter backwash. AB includes air injection procedure followed with a CB cleaning. The air velocity during injection is around 0.6 m·s−1. The flow rate of physical backwash is around 2.5 m3·h−1, the backwash water velocity is 0.64 m·s−1. The detailed procedures of CB and AB are completely shown in Table 4. The different types of physical backwash are edited and represented with different serial numbers in the system to be easily distinguished. The physical backwashes without NaClO all use permeate from T2 (no chlorine tank) as backwash water. The physical backwashes with NaClO use permeate from T1 (tank with chlorine) as backwash water to clean internal membrane, and then use permeate from T2 as backwash water to backwash prefilter. The prefilter backwash as the final backwash step will always be backwashed with permeate from T2 to drain the chlorine in the system pipes and UF module. The flow chart of physical backwashes can be found in Figure 1. The AB has shown their excellent efficiency to remove the fouling whatever the type of water [39,40,41]. Through comparison, one backwash sequence (CB CB CB AB) in all conditions has the same consumption of permeate volume, same energy demand for backwash and air injection, and duration for backwash, the differences among them was only the addition of NaClO or not. This condition (CB CB CB AB) was optimized in a previous study [39].
Before new operating conditions start or if the TMP achieve to 0.3 bar for 60 s, corresponding to permeability of 200 L·m−2·h−1·bar−1 at 20 °C, a chemical enhanced backwash (CEB) was conducted. A set of CEB include an acid CEB and an alkaline CEB. The CEB starts with chemical injection into membrane modules and then a soaking with chemicals to degrade foulants. Chemicals are either sulfuric acid ([H+] = 1000 mg·L−1), or sodium hydroxide ([OH] = 800 mg·L−1) and chlorine ([active Cl] = 50 mg Cl2·L−1). The duration of soaking is 1200 s for each CEB. In addition, a forward flushing happens in the middle of each filtration cycle for about 10 s where 2.0~3.0 m3·h−1 feed water flows fast from bottom to top of the UF module. The forward flushing can assist to decrease aggregation or dense attachment of particulates from the membrane surface [42].

2.3. Filtration Conditions

The experiments were in dead-end, automatically filtration under constant flux mode. Based on the previous study of Yang et al. [39], the optimized filtration condition of this UF pilot plant and adopted in this present paper is a flux at 60 L·m−2·h−1, a filtration cycle time at 60 min, and a backwash sequence of 3 classic backwashes followed by 1 air backwash. The variable in this study is the chlorine addition in backwash water or not. Four backwash conditions were investigated in this test, shown in Table 5. Each condition was conducted continuously for 5–7 days to obtain stable filtration performance. After each condition, several CEBs were operated manually to improve permeability (Lp) to reach around 650 L·m−2·h−1·bar−1, so as to maintain the similarly initial filtration state for the next filtration conditions. To be noted, the parameters including flux and Lp, that could be affected by the temperature, have been normalized to a standard temperature (20 °C) to account for viscosity fluctuations with these parameters. During experiment, the chronological order of conditions is NNNN, NNNY, YYYN and finally YYYY where Y and N indicates, respectively, the presence (Yes) or absence (No) of chlorine during a backwash.
The operation of the four conditions intermittently lasted for 6 months, from October 2020 to June 2021. Low NaClO consumption conditions NNNN and NNNY were tested from October 2020 to December 2020, higher NaClO consumption conditions YYYN and YYYY were mainly tested from March 2021 to June 2021. The operation of each condition was repeated for more than one month for repeated tests to obtain stable and reliable results, and filtration results were compared.

2.4. Analysis

2.4.1. Irreversible and Reversible Fouling Resistance

According to Darcy’s law [43], hydraulic resistance of the fouled membrane was measured with Equation (1):
R t = R irr + R re + R m = TMP μ · J = 1 μ · Lp
where, TMP is the transmembrane pressure (Pa), μ is the viscosity of permeate (Pa·s) and J is the applied flux (m·s−1). The total membrane resistance (Rt) includes three parts of resistances (m−1): irreversible fouling resistance (Rirr) which cannot be removed by backwashes, reversible fouling resistance (Rre) which can be removed by backwashes and membrane resistance (Rm).
The flux at 20 ℃ is calculated through Equation (2) [44]:
J ( 20   ) = μ ( T ) μ ( 20 ) · J ( T ) = J ( T )   · e [ 0.0239 · ( 20 T ) ]
In this context, the resistance composition before backwash and after backwash was emphasized for comparison. In general, the Rirr is considered as the fouling resistance that cannot be removed by CB. Therefore, the resistance composition before the nth backwash (at the end of the nth filtration cycle) includes Rirr and Rre, which can be shown as:
R t end ( n ) = R m + R irr end ( n ) + R re end ( n )
From definition, only Rirr is left on the membrane after backwash (at the beginning of next filtration cycle) without Rre. If it is turn for nth CB, the initial Rirr in the (n + 1) filtration cycle is the same as Rirr(n), as
R irr ini ( n + 1 ) = R irr end ( n ) = R t ini ( n + 1 ) R m
Normally, during filtration with periodic CB, the loosened and residual foulants after CB would be recompressed according to Ye et al. [45], which results in regular increase of Rirr-ini. However, the occurrence of AB will break the rules of Rirr-ini increase after CB. Generally speaking, the residual Rirr-ini after AB will be decreased because AB can provide higher cleaning efficiency on membrane fouling than CB on the same water treatment, as Rirr-ini-AB (n + 1) < Rirr-ini-CB (n). Therefore, to better understand the fouling resistance composition and variation before and after nth backwash at AB (at the end of the nth filtration cycle, n is an integer multiple of 4), the Rirr-end(n) before AB will be estimated by making arithmetic series with the Rirr-end(n-1), Rirr-end(n-2), and Rirr-end(n-3) before CBs (Equation (4)), the equations are as below.
Before AB:
R t end ( n ) = R m + R irr end ( n ) + R re end ( n )
R irr end ( n ) = R irr end ( n 1 ) + 0.5 · [ ( R irr end ( n 1 ) R irr end ( n 2 ) ) + ( R irr end ( n 2 ) R irr end ( n 3 ) ) ]
After AB:
R irr ini ( n ) = R t ini ( n + 1 ) R m
Otherwise, the variation of irreversible fouling versus integral turbidity during filtration can be an indicator to investigate the influence of backwash conditions on filtration performance as the function of the feed water quality. The relationship of Rirr-end variation at each filtration cycle (n) with feed water turbidity integration (Equation (8)) will be considered to investigate the influence of backwash sequence on fouling formation whatever the quality of feed water (represented by the turbidity).
  R irr end   ( n ) R irr end ( 1 ) = f ( Tur   dt )  
Because the relationship here is mainly to investigate the backwash efficiency, therefore the filtration period should be without CEB. When a CEB occurs, the calculation of turbidity integrity should be restarted from 0. Already used to take into account the feed water quality [39], the turbidity integration with time is shown as follows with n = number of filtration cycle, and tc the duration of a filtration cycle:
i = 1 n [ 0 t c Turbidity . dt ] i

2.4.2. Reversibility

Filtration performance can be evaluated by parameters such as backwash effectiveness, fouling rate, and fouling resistance [46]. Backwash effectiveness can be indicated by fouling reversibility which was calculated after each filtration cycle (n) according to [47,48]. Reversibility after each filtration cycle could then be calculated using the initial TMP and final TMP values ( TMP end n   and   TMP ini n ) of the cycle (n) as well as the initial TMP of the next filtration cycle ( TMP ini ( n + 1 ) ). As described above, the flux and viscosity at 20 °C are both constant during each filtration condition. Therefore, the reversibility can be calculated as follows in Equation (10):
Reversibility ( n ) = TMP end n TMP ini ( n + 1 ) TMP end n TMP ini n = R end n R ini ( n + 1 ) R end n R ini n  

2.4.3. Recovery Rates through Mass Balances

In addition to fouling resistances and reversibility, the recovery efficiency of physical backwashes on retained turbidity and retained TOC are illustrated to further verify the effectiveness of physical backwashes. For turbidity, when a sample needs dilution, turbidity is calculated using the following relationship [49,50]:
Tur 0 · V T 0 = Tur d · ( V T 0 + V T d )
Tur0 is the turbidity of the undiluted sample in NTU; Turd is the turbidity of the diluted sample in NTU; VTd is the content of purified water (0 NTU) in the dilution in mL; and VT0 is the content of sample water in mL. The relationship between turbidity and volume is considered to be linear.
For organic matter, the accumulation of dissolved organic matter was already integrated with filtration time in Lin et al. [51]. Therefore, the turbidity and TOC are considered as accumulated amounts in membrane during the filtration cycles, and the removal rates of these parameters can be calculated with the following equations based on the amount of substance balance.
(1)
Turbidity recovery rate:
R Tur = ( Tur Feed   Tur permeate   )   dV 0 ( Tur BW   Tur permeate   )   dV Bw   · 100 % = ( Tur Feed   Tur permeate   ) · J · S · t   ( Tur BW   Tur permeate   ) · V BW   · 100 %
(2)
TOC recovery rate:
R TOC = ( TOC Feed   TOC permeate   )   dV 0 ( TOC BW   TOC permeate   )   dV Bw   · 100 % = ( TOC Feed   TOC permeate   ) · J · S · t   ( TOC BW   TOC permeate   ) · V BW   · 100 %
Here, V0 is the filtration volume through the UF membrane during one filtration cycle, L. VBW is the physical backwash volume during one physical backwash, VBW = 36 L. J is the filtration flux, J = 60 L·h−1·m−2, S is the surface area of UF membrane, S = 9 m2 and t is the filtration time during one filtration cycle, t = 1 h.

2.4.4. Statistical Test

Statistical analysis was used to determine if there was a statistically significant linear regression between backwash reversibility and Rirr before backwash. The hypotheses were analyzed by XLSTAT (Addinsoft, New York, NY, USA), ANOVA test.

2.5. Water Quality Assessment

The turbidity of UF feed was measured and recorded every minute of the pilot plant using a probe TurbiMax W CUS31(Endress Hauser, Nesselwang, Germany). On sampling, the turbidity of UF feed, permeate, and backwashes was tested in laboratory with a turbidity meter (Turb 550 IR, WTW, Germany). A TOC-L machine (Shimadzu, Japan) based on the 680 °C combustion catalytic oxidation method was used to measure the concentration of total organic carbon (TOC). The non-purgeable organic carbon (NPOC) method with a detection limit of 4 μg·L−1 was used.

3. Results

3.1. Permeability Variation

During filtration, the permeability variation gives the hydraulic filtration performance of the UF membrane, as shown in Figure 2. According to Figure 2, the turbidity of UF feed was stabilized around 1 NTU in all conditions. However, the turbidity shows slight periodical variation with time in a day because the feed water quality seems positively correlated to the variations of raw wastewater flow rate as demonstrated in Yang et al. [39]. In addition, the temperature of the four conditions is 21 ± 2 °C and there is also a cyclical variation of temperature during the day and night. Nevertheless, the variation of feed water quality was undergone of all conditions, thus the feed water quality can be considered to have a similar effect on the four conditions. From CEB occurrences, condition NNNN resulted in the highest frequency of CEB, with 1 CEB per day. Additionally, condition YYYY had 1 CEB in 5 days, condition NNNY had 1 CEB in 6 days, and condition YYYN had 1 CEB in 6 days operation, but these three last conditions are similar. From permeability stability, condition NNNN showed the fastest decrease of permeability to 200 L·m−2·h−1·bar−1 which triggered CEB cleaning. Condition NNNY showed stable variation of permeability, the addition of NaClO only in AB largely improved the UF filtration performance compared to NNNN, with only 1 CEB occurrence in 6 days, and the CEB occurred at the 1st day of operation and no CEB occurred in the last 6 days. The reason for faster permeability decreases on the 1st day may be due to the variation of feed water quality, or that the newly cleaned membrane was sensitive to cake deposition which had a higher chance of pore blocking and lower reversibility of backwash. Similarly, Ye et al. [52] found less reversible fouling in the first few cycles of filtration of seawater than in the following cycles. In whole filtration, the permeability in condition NNNY showed a gradual downward trend. The permeability after stabilization in condition YYYN showed the most sustainable variation during one-week filtration, stabilized in 260–580 L·m−2·h−1·bar−1, while the permeability in condition NNNN, NNNY, and YYYY were stabilized on average around 200–500 L·m−2·h−1·bar−1, 230–580 L·m−2·h−1·bar−1, and 300–650 L·m−2·h−1·bar−1, respectively (some individual highs and lows and initial permeability are not taken into account). It seemed that the efficiency of physical backwashes in YYYN was just balanced to the accumulation of fouling rates, especially after 2 days operation, and the permeability after backwash could achieve to 100% recovery. So far, the addition of NaClO in either AB or CB could improve the membrane filtration performances greatly, including more sustainable permeability variation and less CEB occurrences.
The recovered permeability in condition YYYY after backwashes was higher than the others which could be achieved to 700 L·m−2·h−1·bar−1 in the first two days. The CEB in condition YYYY was triggered on the 2nd day of filtration, the fast decrease of permeability mainly occurred in 5–6 filtration cycles before CEB. Except the rapid permeability decrease on the 2nd day, the peak of permeability and average permeability were both higher than the other conditions. Considering that the variation of turbidity in that period was in regular ranges, the exceptional rapid decrease of permeability may be caused by other parameters that were not taken in account, such as the organic matter in the feed water, or low temperature.
A difference of the YYYY condition with the other three conditions was the peak permeability values. The UF membrane was strongly cleaned by CEB before each condition started which indicated that both the reversible and irreversible fouling can be removed greatly. The fouling formation in the first few cycles of each condition may be mainly because of pore blocking which is irreversible, thus the permeability decreased faster at the beginning of filtration than in the following cycles [45,53]; the physical backwash normally cannot recover the permeability back to the initial levels because of their poor separation strength on irreversible foulant. From Figure 2, it can be seen obviously the fast decrease of permeability at the first few cycles in conditions NNNN, NNNY, and YYYN, and even after automatic CEB, the permeability hardly reached 650 L·m−2·h−1·bar−1. In condition YYYY, the permeability could be easily recovered to the 700 L·m−2·h−1·bar−1 with all NaClO-assisted physical backwashes. Before condition YYYY, the pilot plant was just finished with the condition YYYN which already maintained the membrane in very good permeability variation. With NaClO addition both in CB and AB, it seems that the condition YYYY can reach to more than 100% recovery of the decreased permeability in a filtration cycle. The increase of permeability was also observed by Alhweij et al. and Wienk et al. [28,54]. The UF membrane showed quite good removal efficiency on parameters such as turbidity, microplastics, bacteria, virus, and organic matter of UF feed in all conditions, and the permeate quality was detected to be good enough to be reused in non-potable applications as it met reuse guidelines of the WHO [55], reuse standards of France [56], and the most recent EU regulation for agricultural irrigation [57].
To summarize the disinfection efficiency of NaClO, values for concentration multiplied by contact time (CT) considering backwash and CEB occurrences based on the above performance of each condition, measured in mg Cl2·L−1 ·h, were estimated for a simulated 10 years of operation (Table 6). The frequency of CEB occurrence here is estimated after feedback of this study as once per day for NNNN condition and similar for the others, once in 5 days, once in 6 days, and once in 5 days, respectively, for NNNY, YYYN, and YYYY conditions.
Referring to impacts of chlorinated disinfectants on membranes, many studies have reported that NaClO can attack the chemical bonds of polymeric membranes and degrade the membrane material due to long-term exposure or excessive dosage of chemicals [13,23,54,55,56,57,58,59]. Similarly, excessive chlorine can impact the PES membranes, but the degree of impact varies a lot in different studies. Some studies pointed out the occurrence of a PES-chain scission and PES material degradation though excessive chlorination, such as after 28,500 mg·L−1 total free chlorine of NaClO (27,160 mg Cl2·L−1) contact for 8 months [60], or after 200–2400 mg·L−1 total free chlorine of NaClO (190–2287 mg Cl2·L−1) contact for 10–60 d [23]. Fu and Zhang carried out the proposed PES degradation mechanisms that the PES may undergo a chain scission of the backbone structure into sulfonic acid groups and phenyl chloride groups [30]. Hanafi et al. [23] showed that exposure of PES/PVP membranes to NaClO even led to the appearance of macrovoids in the membrane sub-layer. On the contrary, some researchers found slight modification on PES membranes. Alhweij et al. [54] found that only slight changes in PES surface roughness was observed after exposure to 238 mg Cl2·L−1 of NaClO for 3 days. The permeability of PES membrane increased by 74% after chlorine exposure, but SEM images confirmed that there were no observed structural damages on the membrane. Wypysek et al. [61] also stated that a damaged separation skin does not have a significant negative influence on filtration performance of PES membrane. Yadav et al. [29] also mentioned that the changes of PES membrane surface properties was observed after exposure to 10,000–25,000 mg·L−1·day of NaClO (9530–23,825 mg Cl2·L−1·day) at pH 9–12, but no great changes were observed on membrane mechanical properties and tensile strength. However, according to Wang et al. [62], long time exposure to chlorine could impact physical and chemical properties of membranes regardless of the chlorine concentration. This phenomenon can be explained by the study of Abdullah and Bérubé [63], who stated that the more accurate relationship of chemical exposure to membranes should be CnT, not the CT; “n” is the power coefficient and was determined <1 from their experiment, which indicated that the contact time of cleaning had a more severe impact on the changes in the physical/chemical characteristics of the membranes than the NaClO concentration. From Table 6, condition NNNY resulted in the lowest CT of NaClO and equivalent consumption per m3 of permeate compared to the others, while condition NNNN resulted in the highest. Although the CT of NaClO in condition YYYY was lower than that of NNNN, YYYY provided higher contact frequency of NaClO to membranes. Therefore, it is not recommended to apply either YYYY or NNNN condition for long-term filtration purposes in case of the irreversible changes on the membrane.

3.2. Fouling Formation Mechanism

This section investigates the influence of chlorinated backwash on fouling composition. Figure 3 shows the variation of fouling resistance at the end of each filtration cycle in the four conditions. Membrane resistance (Rm) was considered related to the initial permeability in each condition (650 L·m−2·h−1·bar−1) thus was constant at 5.51 × 1011 m−1 in all conditions. From Figure 3, the Rirr and Rre in condition NNNN increased rapidly between neighboring CEBs which can easily increase over Rm. This situation can refer to Akhondi et al. [53] who confirmed the increase of fouling rate with periodic physical backwash under constant flux and dead-end filtration mode, and the fouling rate could be highly increased when the fouling achieves to a certain amount, together with poor reversibility and cleaning efficiency. On the contrary, the variation of Rirr and Rre in conditions with NaClO in backwashes (NNNY, YYYN, YYYY) were mostly under the Rm. In actuality, it is important to limit the fouling deposition on the membrane, especially the Rirr on membrane, due to its negative impacts on hydraulic filtration performance and cleaning efficiency. In condition NNNY, the addition of NaClO in AB largely decreased Rirr and Rre compared to NNNN. Ignoring the filtration from the beginning to the first CEB, the overall Rirr variation can be separated into two parts, the slower increasing rate of overall Rirr from the 2nd to 5th day and the faster increasing rate of overall Rirr from the 5th to 7th day shown in Figure 3. In filtration from 2nd to 5th day, the overall Rirr increasing rate was in slow and steady growth during constant flux dead-end filtration. From each backwash sequence (four filtration cycles with CB, CB, CB, AB), the Rirr accumulated on the membrane was increased in the first three filtration cycles with CBs and was significantly decreased after an AB with NaClO which controlled the overall Rirr at a lower increasing rate. CB without NaClO could carry away partial cake foulant from the membrane surface but could not remove the smallest compounds adsorbed onto the membrane material effectively; when filtration restarts the residual foulant will adhere to the membrane surface again and accumulate continuously [45]. AB itself has powerful strength with air injection to loosen the foulant layer and to break and/or carry away the smaller particles blocked and absorbed into the membrane [41]. Then, after air injection, backwash with NaClO can inactivate the microorganisms and oxidize organic matters deposited on membrane. The cooperation of air flow and NaClO greatly improved the backwash efficiency on foulant cake removal. When the fouling resistance achieved to a certain value, the AB and CB cleaning efficiency was decreased and the accumulation of integral foulant on the membrane became faster than before. Thus, in filtration from 5th to 7th day, a higher overall Rirr rate was observed, and the fouling cake seemed hardly to be removed by CBs and unable to be controlled by ABs.
The distribution of Rirr and Rre in condition YYYN were in the most stable variation, and Rirr was lower than Rre and lower than Rm (Rirr < Rre < Rm). The addition of NaClO in CB showed an advantage on Rirr control from the beginning of the filtration compared to the previous conditions NNNN and NNNY. The variation of Rirr fluctuated slightly around the overall irreversible fouling trendline shown in Figure 3 with periodic ups and downs in YYYN which may be due to the periodic peak and trough periods of influent flow, secondary effluent quality, and temperature during a day, as stated in another paper [39]. The fouling rate was measured to be very low, and the fouling layer deposited in a filtration cycle seemed to be fully removed by backwashes. There is no more accumulation of Rirr after CBs in a backwash sequence in contrast to condition NNNY, thus the fouling removal efficiency of CB was largely improved by NaClO addition. Normally, the PES/PVP blended membranes shows superior hydrophilicity, anti-fouling, oxidative and thermal stability as well as good mechanical property [64,65]. However, when looking at condition YYYY, although the value of Rirr and Rre were both under Rm, the variation of Rirr was in high volatility compared to YYYN. The Rirr sometimes increased very fast, and sometimes it was even lower than that in YYYN. Otherwise, the total fouling resistances (Rirr + Rre) in conditions NNNY, YYYN, and YYYY were in similar ranges, around 4–7 × 1011 m−1 except the points around CEB in condition NNNY and YYYN. As the CEB is triggered at TMP ≥ 0.3 bar for 60 s, the corresponding total fouling resistance is at 1.41 × 1012 m−1 at 20 °C. The total fouling resistance in condition NNNN was more important, which resulted in frequent occurrence of CEB.

3.3. Reversibility of Physical Backwashes

From the previous analysis, the addition of NaClO in CB and AB improves the backwash cleaning efficiency, but it is not clear to know how much it can be improved. Therefore, it is necessary to compare the reversibility, which represents the backwash cleaning efficiency, in different backwash conditions. According to the membrane filtration model by Kalboussi et al. [66], the mass of the cake layer tends towards a constant value as the number of filtration cycles increase. According to the TMP variation in dead-end filtration with periodic backwashes [53,67], the fouling resistance at the end of each filtration cycle would be in increasing trend with filtration cycles continuing, therefore the fouling condition before AB is much closer to that before the third CB. Therefore, the fouling distribution before AB is much closer to the fouling distribution before the third CB compared to that before the first CB and second CB. Table 7 gives the reversibility of AB and the third CB ranges in different conditions, and Figure 4 shows the comparison between them. It can be confirmed that AB has a dominant position in reversibility compared to CB with or without NaClO, and even the addition of 10 mg Cl2 L−1 NaClO in CB could not reach the reversibility of AB without NaClO. Moreover, condition NNNY offered the highest average reversibility of AB (133 ± 16%) and the stable reversibility range (98–174%), and the second highest was condition YYYY. YYYN offered the lowest AB reversibility. The 10 mg Cl2·L−1 NaClO addition in AB improved the reversibility of AB by 15–18% on average through comparison in parallel conditions NNNN and NNNY, and in conditions YYYN and YYYY. However, the addition of 10 mg Cl2·L−1 NaClO in CB improved the reversibility of the third CB by 5% on average through comparison in parallel conditions NNNN and YYYN, and the third CB reversibility in condition NNNY and YYYY was very close to each other. The lowest reversibility of AB in condition YYYN may be because of its highest reversibility of the third CB compared to the other conditions. The cleaning performance of CB and AB mutually restricts and influences each other, as the reversibility in percentage is related to the previous filtration cycle. From the fouling resistance distribution in Section 3.2, the Rirr was controlled in the lowest ranges in YYYN compared to the others with chlorinated CB and indicated that the membrane was rather clean, therefore, the total foulant cake before AB in YYYN would be less than that in conditions NNNN and NNNY, which dealt with both the cake layer formed in one filtration cycle and accumulated foulant after the previous three CBs. Therefore, AB in YYYN did not exert its best removal ability because of the limited total fouling resistance, thus resulted in lower reversibility. On the other hand, although backwash condition YYYN largely improved the fouling management, there was still residual Rirr left on the membrane after chlorinated CB. However, non-chlorinated AB failed to remove these residual foulant which reflected its limitation on particular Rirr removal, while chlorinated AB in condition YYYY could achieve much lower value of Rirr if the sensitivity of the membrane to fouling is ignored.
To further investigate the impacts of irreversible fouling on cleaning efficiency by physical backwash, the relationship of backwash reversibility versus the Rirr on the membrane just before the corresponding AB or CB and the dynamic trendlines are shown in Figure 5 and Figure 6. The cases of CB in Figure 6 include the first CB, second CB, and third CB of all backwash sequences. The statistical test showed positive linear regression between AB reversibility and Rirr before AB in all conditions (p-value < 0.05) and showed significant negative linear regression on CB reversibility and Rirr before CB in condition NNNN, YYYN, and YYYY, while condition NNNY (p = 0.066) was not very significant. However, the data here were mainly shown to know the variation tendency (increase or decrease, not necessarily linearly) of the AB or CB reversibility versus total irreversible fouling resistance before the backwash. Therefore, the significances of both AB and CB under 90% confidential interval can be totally supported.
The reversibility of AB whether with or without NaClO was shown in positive correlation to Rirr from Figure 5, while the reversibility of CB with or without NaClO was shown in negative correlation to Rirr from Figure 6. This means that the cleaning capacity of AB will be increased with the increase of Rirr leading to better filtration performance, but the removal capacity of CB will be decreased with the increase of Rirr causing harsh filtration performance. From Figure 5, the increasing rates of AB reversibility with Rirr in all conditions were similar, the reversibility of AB under the same Rirr was in YYYY higher than NNNY, and higher than NNNN and YYYN. The addition of NaClO in AB indeed improved its cleaning efficiency as NNNY and YYYY were both in higher reversibility compared to NNNN and NNNY whatever the value of Rirr.
From Figure 6, the reversibility of CB was decreased with the deposited Rirr increase and validated the higher performance of AB in comparison on CB. The slight decline of CB reversibility in conditions NNNN and NNNY was very close to each other and both conditions used non-chlorinated CB for cleaning. The CB of YYYN and YYYY showed higher reversibility with lower Rirr deposition, but the CB reversibility decreased faster with Rirr increase compared to condition NNNN and NNNY. On the one hand, the chlorinated CB resulted in higher reversibility that could better control Rirr in lower levels. On the other hand, although chlorinated CB was good at Rirr controlling, it had poor adaptability and lower reversibility when Rirr increased. Looking back to NNNN and NNNY, the cleaning efficiency of non-chlorinated CB was more stable and sustainable with Rirr variation. Condition YYYN had the best fouling resistance management, non-chlorinated AB resulted in lower reversibility which was much closer to the performance of chlorinated CB. Both conditions YYYN and YYYY showed faster decrease of CB reversibility with Rirr increase. From this point, condition NNNY is more recommended as the optimized backwash condition which showed relatively higher effective and stable reversibility variation both of AB and CB compared to other conditions.

3.4. Cake Layer Removal Efficiency by Backwash through Mass Balance

In general, as the cake layer mass grows in proportion to the concentration of foulants in the feed, and to the total volume of feed passing through the membrane, the cake layer resistance is proportional to the mass accumulated on the membrane surface [67]. Table 8 shows the water quality of AB, third CB, UF feed, and UF permeate in different conditions, and Figure 7a,b is the turbidity and TOC removal rates by AB and third CB through mass balance in a filtration cycle.
Figure 7a shows that the percentage of turbidity recovered by the third CB is always below 80% which indicated there would be an increased foulant deposition of this residual turbidity after CB together with the new turbidity accumulation for the next filtration cycle. The turbidity removal capacity of the third CB was improved by 15–30% with 10 mg Cl2·L−1 NaClO addition compared to the non-chlorinated third CB. Additionally, the turbidity removal performance of AB was much better than CB, as the lowest removal rate was around 88% on average. The chlorinated AB in condition NNNY showed the highest, with 136% removal of turbidity from concentrate, which means the chlorinated AB completely removed the total turbidity accumulated in its own filtration cycle and removed part of the residual turbidity from the previous filtration cycles. The turbidity recovery performances of AB in conditions NNNN, YYYN, and YYYY were very similar, and the chlorinated AB in condition YYYY showed no improvement on turbidity removal. The removal efficiency of AB in condition NNNY was the highest compared to the other three conditions almost in similar efficiency.
From Figure 7b, it is obvious to see the high improvement of TOC recovery in conditions with NaClO compared to NNNN. In condition NNNN, the third CB and AB, both without NaClO, showed similar and low removal efficiency on TOC. TOC recovery rate by chlorinated AB was highly improved to more than 200% while by the third CB, it was only 50% in condition NNNY. Otherwise, the addition of NaClO in CB also greatly improved the TOC recovery rates as in conditions YYYN and YYYY. Through comparison, the addition of NaClO in CB showed higher removal capacity on TOC compared to turbidity removal.
Therefore, for TOC and turbidity recovery, when no NaClO is added in CBs (NNNN and NNNY), the AB, either with or without NaClO, will greatly improve the removal efficiency on turbidity thus compensates to the low removal efficiency of CB without NaClO. When adding NaClO in CBs (YYYN and YYYY), CB with NaClO will improve the removal efficiency on turbidity previous to AB, thus AB either with or without NaClO is proportionally less effective compared to CB with NaClO.
Based on the analysis on filtration permeability, fouling resistance distribution, backwash reversibility, and cake layer removal ability, it can be concluded that the addition of 10 mg Cl2·L−1 NaClO in AB and CB can greatly improve the overall filtration performance and cleaning efficiency. Through comparison, the condition NNNN was not suggested for operation because of the frequent CEB occurrence, fastest Rirr increase and poor cleaning efficiency by CB and AB. Condition YYYY was not recommended because of its potential damage on membrane material with most frequent contact with NaClO, unstable permeability and Rirr variation, and unstable cleaning efficiency of CB. YYYN was offered in the best fouling resistance control and permeability recovery, but the chlorinated CB showed lower reversibility when faced with higher Rirr on the membrane. Additionally, the addition of NaClO in condition YYYN will be higher that NNNY under the same operation period, which would increase the operating costs and may cause faster damage on membrane structures. Although the control of Rirr in condition NNNY was not as good as in condition YYYN, it was in slight and sustainable increase resulted in only 1 CEB occurrence in 6 days. Condition NNNY can be considered as the most cost-effective backwash condition in this study mainly due to less consumption of NaClO, sustainable and adaptable filtration performance, and less potential damage on the physicochemical characteristics of membrane. Therefore, the condition NNNY is recommended for long-term operation.

3.5. The Influence of NaClO Concentration on Air Backwash Efficiency of Condition NNNY

As backwash sequence has been optimized in condition NNNY, it is necessary to further investigate the performance of NNNY condition with different concentrations of NaClO addition. The concentration of NaClO at 5 mg Cl2·L−1 and 10 mg Cl2·L−1 in condition NNNY are compared on the filtration performance. The long-term filtration results of 5 mg Cl2·L−1 NaClO condition has already been shown in another paper [39], of which the frequency of CEB occurrence was once in three days. In this study, the CEB occurred once in six days in NNNY with 10 mg Cl2·L−1 NaClO. To be compared, the variation of Rirr at the end of each filtration cycle in 5 mg Cl2·L−1 NaClO and 10 mg Cl2·L−1 NaClO conditions is shown in Figure 8. The Y axis Rirr-end (n)/Rirr-end (1) represents the increasing ration of Rirr-end during filtration, and X axis represents the foulant cake mass accumulation during filtration. Within 1000 NTU·min integration, the variation of Rirr-end (n)/Rirr-end (1) in condition NNNY with 5 mg Cl2·L−1 and 10 mg Cl2·L−1 of NaClO was closer to each other, and the ration of Rirr-end (n)/Rirr-end (1) was all under 5. After this, the Rirr increasing rate in 5 mg Cl2·L−1 NaClO condition was increased much faster than before 1000 NTU·min integration, while the variation in 10 mg Cl2·L−1 NaClO condition was continuously in sustainable and slight increase. The Rirr variation in condition NNNY with 5 mg Cl2·L−1 and 10 mg Cl2·L−1 NaClO was from 1.02 × 1011 m−1 to 9.17 × 1011 m−1, and from 1.35 × 1011 m−1 to 6.57 × 1011 m−1, respectively. The faster increase of Rirr-end after 1000 NTU·min integration in 5 mg Cl2·L−1 NaClO condition may be due to more complex structure of foulant cake layer and increased local flux due to loss of effective filtration area, as stated in Section 3.2 of condition NNNY. Higher concentration of NaClO at 10 mg Cl2·L−1 increased the chance to inactivate organisms, detach cake foulant, extend the time to form more complex fouling, and improve the load capacity on feed water quality. Therefore, the increase of NaClO concentration in condition NNNY indeed improved the AB cleaning efficiency and the overall Rirr control during filtration. It was found that 10 mg Cl2·L−1 NaClO is more effective on fouling control in condition NNNY.

4. Discussion

In this study, 10 mg Cl2·L−1 NaClO addition in backwash water can positively improve the filtration performance of a UF pilot plant. From Table 7 and Figure 4, the addition of NaClO had significant improvement on AB cleaning efficiency when comparing condition NNNN and NNNY, or comparing condition YYYN and YYYY, resulting in a 15–18% increase of reversibility. However, NaClO addition itself almost had less improvement on the third CB cleaning, with an average of 1–5% increasing of reversibility when comparing condition NNNN and YYYN, or condition NNNY and YYYY. In this case, it seems that air injection contributes more to enhance the NaClO-assisted backwash cleaning. In NaClO-assisted AB, air injection with strong shear force can break and dried the foulant layer on membrane, thus increasing contact area of foulant and chlorinated backwash water. The cooperation of air injection and NaClO oxidation on fouling highly improved the cleaning efficiency of backwash. Additionally, comparing the performance of AB and third CB in all conditions, the reversibility of AB (with or without NaClO) was completely higher than that of CB (with or without NaClO). Therefore, it seems that the effects of air injection on CB were more significant than NaClO assistance in CB water; this can be considered as AB without NaClO in this study has higher cleaning efficiency than CB with NaClO, see as in condition YYYN. Based on the comparison on efficiency of chemical cleaning and physical cleaning from Park et al. [68], extending contact time of chemical cleaning was one of the important factors on improvement of membrane permeability recovery compared to physical cleaning. In our study, the contact time of chlorinated backwash water through the membrane is 52 s in total. The disinfection and oxidation reactions between NaClO and cake foulants cannot be completely reacted in shorter contact time, thus the cleaning efficiency of chlorinated CB was limited in this study. In contrast, the physical assistance by air injection could greatly improve the cleaning efficiency. As was the case for Guigui et al. [69], air injection even at very low air velocity (0.08 m·s−1) could result in a high backwash efficiency, and normally, the duration of air injection does not need too long; less than 2 min is enough. Based on the above analysis, air injection assistance on CB (AB) indeed provides higher contributions on fouling removal than 10 mg Cl2·L−1 NaClO. However, the comparison conditions of AB and NaClO-assisted CB in this study could be completed with consideration of all impact factors. The impact factors include air injection duration, air velocity, NaClO concentration in backwash water, temperature, and NaClO contact time with membrane. Additionally, the co-effects among these factors are complex and could be investigated in the future.

5. Conclusions

In conclusion, 10 mg Cl2·L−1 NaClO addition in backwash water is confirmed to greatly improve the overall filtration performance and backwash cleaning efficiency. During this experiment, the chronological order of conditions is NNNN, NNNY, YYYN, and finally YYYY. The type of backwash among all conditions is three CBs followed with one AB. N represents a backwash either CB or AB without NaClO and Y represents a backwash either CB or AB with NaClO. First, condition NNNY stands out from the other due to better control of Rirr, less NaClO consumption in 10 years prediction, sustainable and adaptable filtration performance, and less potential damage on the physicochemical properties of the membrane. The second best condition is YYYN, which resulted in the best fouling control and permeability recovery, but it has higher potential to damage membrane structures under frequent NaClO addition. In all conditions, AB showed positive correlation of reversibility and Rirr increase, but CB showed negative correlation of reversibility and Rirr increase. Furthermore, even CB added with 10 mg Cl2·L−1 NaClO hardly exceeds the reversibility of AB without chlorine. These results reflect that AB itself, whether with or without NaClO, has high cleaning efficiency on fouling removal, and is especially better on Rirr control. Through comparison of 5 mg Cl2·L−1 and 10 mg Cl2·L−1 NaClO in condition NNNY, higher NaClO concentration increased the chance to inactivate organisms, detach cake foulant, extend the time to more complex fouling formation, and improve the load capacity on feed water quality. Therefore, condition NNNY with 10 mg Cl2·L−1 NaClO is mostly recommended for long-term operation in this study on secondary effluent treatment.

Author Contributions

J.Y. wrote the manuscript with support, input and discussions from M.M., P.M. and L.E. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

The authors would like to acknowledge the China Scholarship Council for partial financial support (201801810046).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Chang, I.-S.; Kim, S.-N. Wastewater Treatment Using Membrane Filtration—Effect of Biosolids Concentration on Cake Resistance. Process Biochem. 2005, 40, 1307–1314. [Google Scholar] [CrossRef]
  2. Yang, J.; Monnot, M.; Ercolei, L.; Moulin, P. Membrane-Based Processes Used in Municipal Wastewater Treatment for Water Reuse: State-of-the-Art and Performance Analysis. Membranes 2020, 10, 131. [Google Scholar] [CrossRef] [PubMed]
  3. Shi, X.; Tal, G.; Hankins, N.P.; Gitis, V. Fouling and Cleaning of Ultrafiltration Membranes: A Review. J. Water Process Eng. 2014, 1, 121–138. [Google Scholar] [CrossRef]
  4. Judd, S. The MBR Book: Principles and Applications of Membrane Bioreactors for Water and Wastewater Treatment; Elsevier: Amsterdam, The Netherlands, 2010; ISBN 978-0-08-096767-7. [Google Scholar]
  5. Li, Q.; Elimelech, M. Organic Fouling and Chemical Cleaning of Nanofiltration Membranes:  Measurements and Mechanisms. Environ. Sci. Technol. 2004, 38, 4683–4693. [Google Scholar] [CrossRef]
  6. Regula, C.; Carretier, E.; Wyart, Y.; Gésan-Guiziou, G.; Vincent, A.; Boudot, D.; Moulin, P. Chemical Cleaning/Disinfection and Ageing of Organic UF Membranes: A Review. Water Res. 2014, 56, 325–365. [Google Scholar] [CrossRef] [PubMed]
  7. Meng, F.; Zhang, S.; Oh, Y.; Zhou, Z.; Shin, H.-S.; Chae, S.-R. Fouling in Membrane Bioreactors: An Updated Review. Water Res. 2017, 114, 151–180. [Google Scholar] [CrossRef] [PubMed]
  8. Wang, Z.; Meng, F.; He, X.; Zhou, Z.; Huang, L.-N.; Liang, S. Optimisation and Performance of NaClO-Assisted Maintenance Cleaning for Fouling Control in Membrane Bioreactors. Water Res. 2014, 53, 1–11. [Google Scholar] [CrossRef]
  9. Yue, X.; Koh, Y.K.K.; Ng, H.Y. Membrane Fouling Mitigation by NaClO-Assisted Backwash in Anaerobic Ceramic Membrane Bioreactors for the Treatment of Domestic Wastewater. Bioresour. Technol. 2018, 268, 622–632. [Google Scholar] [CrossRef]
  10. Shao, S.; Wang, Y.; Shi, D.; Zhang, X.; Tang, C.Y.; Liu, Z.; Li, J. Biofouling in Ultrafiltration Process for Drinking Water Treatment and Its Control by Chlorinated-Water and Pure Water Backwashing. Sci. Total Environ. 2018, 644, 306–314. [Google Scholar] [CrossRef]
  11. Weerasekara, N.A.; Choo, K.-H.; Lee, C.-H. Biofouling Control: Bacterial Quorum Quenching versus Chlorination in Membrane Bioreactors. Water Res. 2016, 103, 293–301. [Google Scholar] [CrossRef]
  12. Yu, W.; Xu, L.; Graham, N.; Qu, J. Pre-Treatment for Ultrafiltration: Effect of Pre-Chlorination on Membrane Fouling. Sci. Rep. 2014, 4, 6513. [Google Scholar] [CrossRef]
  13. Luo, J.; Huang, W.; Zhang, Q.; Wu, Y.; Fang, F.; Cao, J.; Su, Y. Distinct Effects of Hypochlorite Types on the Reduction of Antibiotic Resistance Genes during Waste Activated Sludge Fermentation: Insights of Bacterial Community, Cellular Activity, and Genetic Expression. J. Hazard. Mater. 2021, 403, 124010. [Google Scholar] [CrossRef]
  14. Sensorex. Free Chlorine vs. Total Chlorine: What’s the Difference? 2020. Available online: https://sensorex.com/blog/2020/02/11/free-chlorine-vs-total-chlorine/ (accessed on 24 September 2021).
  15. Block, S.S. Disinfection, Sterilization, and Preservation; Lippincott Williams & Wilkins: Philadelphia, PA, USA, 2001; ISBN 978-0-683-30740-5. [Google Scholar]
  16. Rutala, W.A.; Weber, D.J.; HICPAC. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008; HICPAC: Atlanta, GA, USA, 2008; p. 163. [Google Scholar]
  17. Cai, W.; Liu, Y. Enhanced Membrane Biofouling Potential by On-Line Chemical Cleaning in Membrane Bioreactor. J. Membr. Sci. 2016, 511, 84–91. [Google Scholar] [CrossRef]
  18. Wei, C.-H.; Huang, X.; Ben Aim, R.; Yamamoto, K.; Amy, G. Critical Flux and Chemical Cleaning-in-Place during the Long-Term Operation of a Pilot-Scale Submerged Membrane Bioreactor for Municipal Wastewater Treatment. Water Res. 2011, 45, 863–871. [Google Scholar] [CrossRef]
  19. Zhai, S.; Zhang, W.; Li, T.; Zhang, W.; Lv, L.; Pan, B. Sodium Hypochlorite Assisted Membrane Cleaning: Alterations in the Characteristics of Organic Foulants and Membrane Permeability. Chemosphere 2018, 211, 139–148. [Google Scholar] [CrossRef] [PubMed]
  20. Watson, K.; Shaw, G.; Leusch, F.D.L.; Knight, N.L. Chlorine Disinfection By-Products in Wastewater Effluent: Bioassay-Based Assessment of Toxicological Impact. Water Res. 2012, 46, 6069–6083. [Google Scholar] [CrossRef] [PubMed]
  21. Caravelli, A.; Contreras, E.M.; Giannuzzi, L.; Zaritzky, N. Modeling of Chlorine Effect on Floc Forming and Filamentous Micro-Organisms of Activated Sludges. Water Res. 2003, 37, 2097–2105. [Google Scholar] [CrossRef]
  22. Lim, B.-R.; Ahn, K.-H.; Song, K.-G.; Cho, J.W. Microbial Community in Biofilm on Membrane Surface of Submerged MBR: Effect of in-Line Cleaning Chemical Agent. Water Sci. Technol. 2005, 51, 201–207. [Google Scholar] [CrossRef] [PubMed]
  23. Hanafi, Y.; Loulergue, P.; Ababou-Girard, S.; Mériadec, C.; Rabiller-Baudry, M.; Baddari, K.; Szymczyk, A. Electrokinetic Analysis of PES/PVP Membranes Aged by Sodium Hypochlorite Solutions at Different PH. J. Membr. Sci. 2016, 501, 24. [Google Scholar] [CrossRef]
  24. Regula, C.; Carretier, E.; Wyart, Y.; Sergent, M.; Gésan-Guiziou, G.; Ferry, D.; Vincent, A.; Boudot, D.; Moulin, P. Ageing of Ultrafiltration Membranes in Contact with Sodium Hypochlorite and Commercial Oxidant: Experimental Designs as a New Ageing Protocol. Sep. Purif. Technol. 2013, 103, 119–138. [Google Scholar] [CrossRef]
  25. Rouaix, S.; Causserand, C.; Aimar, P. Experimental Study of the Effects of Hypochlorite on Polysulfone Membrane Properties. J. Membr. Sci. 2006, 2, 137–147. [Google Scholar] [CrossRef] [Green Version]
  26. Gabelich, C.J.; Frankin, J.C.; Gerringer, F.W.; Ishida, K.P.; Suffet, I.H. (Mel) Enhanced Oxidation of Polyamide Membranes Using Monochloramine and Ferrous Iron. J. Membr. Sci. 2005, 258, 64–70. [Google Scholar] [CrossRef]
  27. Arkhangelsky, E.; Kuzmenko, D.; Gitis, V. Impact of Chemical Cleaning on Properties and Functioning of Polyethersulfone Membranes. J. Membr. Sci. 2007, 305, 176–184. [Google Scholar] [CrossRef]
  28. Wienk, I.M.; Meuleman, E.E.B.; Borneman, Z.; Van Den Boomgaard, T.; Smolders, C.A. Chemical Treatment of Membranes of a Polymer Blend: Mechanism of the Reaction of Hypochlorite with Poly(Vinyl Pyrrolidone). J. Polym. Sci. Part A Polym. Chem. 1995, 33, 49–54. [Google Scholar] [CrossRef] [Green Version]
  29. Yadav, K.; Morison, K.; Staiger, M.P. Effects of Hypochlorite Treatment on the Surface Morphology and Mechanical Properties of Polyethersulfone Ultrafiltration Membranes. Polym. Degrad. Stab. 2009, 94, 1955–1961. [Google Scholar] [CrossRef]
  30. Fu, W.; Zhang, W. Chemical Aging and Impacts on Hydrophilic and Hydrophobic Polyether Sulfone (PES) Membrane Filtration Performances. Polym. Degrad. Stab. 2019, 168, 108960. [Google Scholar] [CrossRef]
  31. Fukuzaki, S. Mechanisms of Actions of Sodium Hypochlorite in Cleaning and Disinfection Processes. Biocontrol Sci. 2006, 11, 147–157. [Google Scholar] [CrossRef]
  32. Wang, L.; Wang, X.; Fukushi, K. Effects of Operational Conditions on Ultrafiltration Membrane Fouling. Desalination 2008, 229, 181–191. [Google Scholar] [CrossRef]
  33. Liu, G.; Li, L.; Qiu, L.; Yu, S.; Liu, P.; Zhu, Y.; Hu, J.; Liu, Z.; Zhao, D.; Yang, H. Chemical Cleaning of Ultrafiltration Membranes for Polymer-Flooding Wastewater Treatment: Efficiency and Molecular Mechanisms. J. Membr. Sci. 2018, 545, 348–357. [Google Scholar] [CrossRef]
  34. Decarolis, J.; Hong, S.; Taylor, J. Fouling Behavior of a Pilot Scale Inside-out Hollow Fiber UF Membrane during Dead-End Filtration of Tertiary Wastewater. J. Membr. Sci. 2001, 191, 165–178. [Google Scholar] [CrossRef]
  35. Chemical Cleaning of Fouled PVC Membrane during Ultrafiltration of Algal-Rich Water. J. Environ. Sci. 2011, 23, 529–536. [CrossRef]
  36. Chen, J.P.; Kim, S.L.; Ting, Y.P. Optimization of Membrane Physical and Chemical Cleaning by a Statistically Designed Approach. J. Membr. Sci. 2003, 219, 27–45. [Google Scholar] [CrossRef]
  37. Nguyen, S.T.; Roddick, F.A. Chemical Cleaning of Ultrafiltration Membrane Fouled by an Activated Sludge Effluent. Desalination Water Treat. 2011, 34, 94–99. [Google Scholar] [CrossRef]
  38. Jiang, C.-K.; Tang, X.; Tan, H.; Feng, F.; Xu, Z.-M.; Mahmood, Q.; Zeng, W.; Min, X.-B.; Tang, C.-J. Effect of Scrubbing by NaClO Backwashing on Membrane Fouling in Anammox MBR. Sci. Total Environ. 2019, 670, 149–157. [Google Scholar] [CrossRef]
  39. Yang, J.; Monnot, M.; Eljaddi, T.; Ercolei, L.; Simonian, L.; Moulin, P. Ultrafiltration as Tertiary Treatment for Municipal Wastewater Reuse. Sep. Purif. Technol. 2021, 272, 118921. [Google Scholar] [CrossRef]
  40. Cordier, C.; Eljaddi, T.; Ibouroihim, N.; Stavrakakis, C.; Sauvade, P.; Coelho, F.; Moulin, P. Optimization of Air Backwash Frequency during the Ultrafiltration of Seawater. Membranes 2020, 10, 78. [Google Scholar] [CrossRef]
  41. Cordier, C.; Stavrakakis, C.; Sauvade, P.; Coelho, F.; Moulin, P. Air Backwash Efficiency on Organic Fouling of UF Membranes Applied to Shellfish Hatchery Effluents. Membranes 2018, 8, 48. [Google Scholar] [CrossRef] [Green Version]
  42. Gao, W.; Liang, H.; Ma, J.; Han, M.; Chen, Z.; Han, Z.; Li, G. Membrane Fouling Control in Ultrafiltration Technology for Drinking Water Production: A Review. Desalination 2011, 272, 1–8. [Google Scholar] [CrossRef]
  43. Wiesner, M.R.; Aptel, P. Mass Transport and Permeate Flux and Fouling in Pressure-Driven Process. In Water Treatment Membrane Handbook; McGraw-Hill: New York, NY, USA, 1996; ISBN 978-0-07-001559-3. [Google Scholar]
  44. Howell, J.; Field, R.; Wu, D. Ultrafiltration of High-Viscosity Solutions: Theoretical Developments and Experimental Findings. Chem. Eng. Sci. 1996, 51, 1405–1415. [Google Scholar] [CrossRef]
  45. Ye, Y.; Chen, V.; Le-Clech, P. Evolution of Fouling Deposition and Removal on Hollow Fibre Membrane during Filtration with Periodical Backwash. Desalination 2011, 283, 198–205. [Google Scholar] [CrossRef]
  46. Resosudarmo, A.; Ye, Y.; Le-Clech, P.; Chen, V. Analysis of UF Membrane Fouling Mechanisms Caused by Organic Interactions in Seawater. Water Res. 2013, 47, 911–921. [Google Scholar] [CrossRef]
  47. Chang, H.; Liang, H.; Qu, F.; Shao, S.; Yu, H.; Liu, B.; Gao, W.; Li, G. Role of Backwash Water Composition in Alleviating Ultrafiltration Membrane Fouling by Sodium Alginate and the Effectiveness of Salt Backwashing. J. Membr. Sci. 2016, 499, 429–441. [Google Scholar] [CrossRef]
  48. Chang, H.; Liang, H.; Qu, F.; Liu, B.; Yu, H.; Du, X.; Li, G.; Snyder, S.A. Hydraulic Backwashing for Low-Pressure Membranes in Drinking Water Treatment: A Review. J. Membr. Sci. 2017, 540, 362–380. [Google Scholar] [CrossRef]
  49. Guidance Manual for Compliance with the Interim Enhanced Surface Water Treatment Rule: Turbity Provisions; Office of Water: Washington, DC, USA, 1999.
  50. Pavanelli, D.; Bigi, A. Indirect Methods to Estimate Suspended Sediment Concentration: Reliability and Relationship of Turbidity and Settleable Solids. Biosyst. Eng. 2005, 90, 75–83. [Google Scholar] [CrossRef]
  51. Lin, C.-F.; Yu-Chen Lin, A.; Sri Chandana, P.; Tsai, C.-Y. Effects of Mass Retention of Dissolved Organic Matter and Membrane Pore Size on Membrane Fouling and Flux Decline. Water Res. 2009, 43, 389–394. [Google Scholar] [CrossRef]
  52. Ye, Y.; Sim, L.N.; Herulah, B.; Chen, V.; Fane, A.G. Effects of Operating Conditions on Submerged Hollow Fibre Membrane Systems Used as Pre-Treatment for Seawater Reverse Osmosis. J. Membr. Sci. 2010, 365, 78–88. [Google Scholar] [CrossRef]
  53. Akhondi, E.; Wicaksana, F.; Fane, A.G. Evaluation of Fouling Deposition, Fouling Reversibility and Energy Consumption of Submerged Hollow Fiber Membrane Systems with Periodic Backwash. J. Membr. Sci. 2014, 452, 319–331. [Google Scholar] [CrossRef]
  54. Alhweij, H.; Amura, I.; Wenk, J.; Emanuelsson, E.A.C.; Shahid, S. Self-Doped Sulfonated Polyaniline Ultrafiltration Membranes with Enhanced Chlorine Resistance and Antifouling Properties. J. Appl. Polym. Sci. 2021, 138, 50756. [Google Scholar] [CrossRef]
  55. World Health Organization. Guidelines for the Safe Use of Wastewater, Excreta and Greywater; World Health Organization: Geneva, Switzerland, 2006; Volume 4. [Google Scholar]
  56. Légifrance. Arrêté Du 2 Août 2010 Relatif à L’utilisation D’eaux Issues Du Traitement D’épuration Des Eaux Résiduaires Urbaines Pour L’irrigation De Cultures Ou D’espaces Verts. 2010. Available online: https://www.legifrance.gouv.fr/loda/id/JORFTEXT000022753522/ (accessed on 24 September 2021).
  57. European Parliament. European Parliament Legislative Resolution of 13 May 2020 on the Council Position at First Reading with a View to the Adoption of a Regulation of the European Parliament and of the Council on Minimum Requirements for Water Reuse (15301/2/2019–C9-0107/2020–2018/0169(COD)). 2020. Available online: https://op.europa.eu/en/publication-detail/-/publication/ea0faa83-a1c0-11eb-b85c-01aa75ed71a1 (accessed on 24 September 2021).
  58. Gohil, J.M.; Suresh, A.K. Chlorine Attack on Reverse Osmosis Membranes: Mechanisms and Mitigation Strategies. J. Membr. Sci. 2017, 541, 108–126. [Google Scholar] [CrossRef]
  59. Son, S.H.; Jegal, J. Preparation and Characterization of Polyamide Reverse-Osmosis Membranes with Good Chlorine Tolerance. J. Appl. Polym. Sci. 2011, 120, 1245–1252. [Google Scholar] [CrossRef]
  60. Kourde-Hanafi, Y.; Loulergue, P.; Szymczyk, A.; Van der Bruggen, B.; Nachtnebel, M.; Rabiller-Baudry, M.; Audic, J.-L.; Pölt, P.; Baddari, K. Influence of PVP Content on Degradation of PES/PVP Membranes: Insights from Characterization of Membranes with Controlled Composition. J. Membr. Sci. 2017, 533, 261–269. [Google Scholar] [CrossRef]
  61. Wypysek, D.; Rall, D.; Wiese, M.; Neef, T.; Koops, G.; Wessling, M. Shell and Lumen Side Flow and Pressure Communication during Permeation and Filtration in a Multibore Polymer Membrane Module. J. Membr. Sci. 2019, 584, 254–267. [Google Scholar] [CrossRef] [Green Version]
  62. Wang, Y.; Wang, Z.; Wang, J. Lab-Scale and Pilot-Scale Fabrication of Amine-Functional Reverse Osmosis Membrane with Improved Chlorine Resistance and Antimicrobial Property. J. Membr. Sci. 2018, 554, 221–231. [Google Scholar] [CrossRef]
  63. Abdullah, S.Z.; Bérubé, P.R. Assessing the Effects of Sodium Hypochlorite Exposure on the Characteristics of PVDF Based Membranes. Water Res. 2013, 47, 5392–5399. [Google Scholar] [CrossRef]
  64. Vatsha, B.; Ngila, J.C.; Moutloali, R.M. Preparation of Antifouling Polyvinylpyrrolidone (PVP 40K) Modified Polyethersulfone (PES) Ultrafiltration (UF) Membrane for Water Purification. Phys. Chem. Earth Parts A/B/C 2014, 67–69, 125–131. [Google Scholar] [CrossRef]
  65. Zhao, C.; Xue, J.; Ran, F.; Sun, S. Modification of Polyethersulfone Membranes—A Review of Methods. Prog. Mater. Sci. 2013, 58, 76–150. [Google Scholar] [CrossRef]
  66. Kalboussi, N.; Harmand, J.; Rapaport, A.; Bayen, T.; Ellouze, F.; Ben Amar, N. Optimal Control of Physical Backwash Strategy—Towards the Enhancement of Membrane Filtration Process Performance. J. Membr. Sci. 2018, 545, 38–48. [Google Scholar] [CrossRef] [Green Version]
  67. Remize, P.J.; Guigui, C.; Cabassud, C. Evaluation of Backwash Efficiency, Definition of Remaining Fouling and Characterisation of Its Contribution in Irreversible Fouling: Case of Drinking Water Production by Air-Assisted Ultra-Filtration. J. Membr. Sci. 2010, 355, 104–111. [Google Scholar] [CrossRef]
  68. Park, S.; Kang, J.S.; Lee, J.J.; Vo, T.K.Q.; Kim, H.S. Application of Physical and Chemical Enhanced Backwashing to Reduce Membrane Fouling in the Water Treatment Process Using Ceramic Membranes. Membranes 2018, 8, 110. [Google Scholar] [CrossRef] [Green Version]
  69. Guigui, C.; Mougenot, M.; Cabassud, C. Air sparging backwash in ultrafiltration hollow fibres for drinking water production. Water Supply 2003, 3, 415–422. [Google Scholar] [CrossRef]
Figure 1. Diagram of semi-industrial pilot plant.
Figure 1. Diagram of semi-industrial pilot plant.
Membranes 11 00733 g001
Figure 2. Permeability, feed water turbidity and temperature variation versus time in different backwash conditions.
Figure 2. Permeability, feed water turbidity and temperature variation versus time in different backwash conditions.
Membranes 11 00733 g002
Figure 3. Fouling resistance variation versus time in different backwash conditions.
Figure 3. Fouling resistance variation versus time in different backwash conditions.
Membranes 11 00733 g003
Figure 4. Reversibility ranges of air backwash (AB) and 3rd chemical backwash (CB) in different conditions.
Figure 4. Reversibility ranges of air backwash (AB) and 3rd chemical backwash (CB) in different conditions.
Membranes 11 00733 g004
Figure 5. Reversibility of AB versus Rirr on the membrane just before AB.
Figure 5. Reversibility of AB versus Rirr on the membrane just before AB.
Membranes 11 00733 g005
Figure 6. Reversibility of CB versus Rirr on the membrane just before CB.
Figure 6. Reversibility of CB versus Rirr on the membrane just before CB.
Membranes 11 00733 g006
Figure 7. (a) Turbidity recovery rates of AB and 3rd CB, (b) TOC recovery rates of AB and 3rd CB.
Figure 7. (a) Turbidity recovery rates of AB and 3rd CB, (b) TOC recovery rates of AB and 3rd CB.
Membranes 11 00733 g007
Figure 8. Variation of Rirr-end of filtration cycle (n) to the initial cycle (1) a function of the integral of turbidity vs. time.
Figure 8. Variation of Rirr-end of filtration cycle (n) to the initial cycle (1) a function of the integral of turbidity vs. time.
Membranes 11 00733 g008
Table 1. Studies on the combined physical backwash with low concentrated oxidants/disinfectants in backwash water.
Table 1. Studies on the combined physical backwash with low concentrated oxidants/disinfectants in backwash water.
No.Backwash TypesConcentration Backwash
Time × Flux or TMP
Filtration Time × FluxFeed WaterMembrane Process (Pore Size/Area)RemarksRef.
1NaClO-assisted backwash23.8 mg Cl2·L−124 s/(207–241.5 kPa)(15–30 min) × (34–102 L·m−2·h−1)Tertiary treated wastewaterUF (150 kDa/1.9 m2)● Frequent backwash with chlorine addition significantly improved membrane productivity, primarily due to enhanced foulant removal by organic oxidation and bio-growth control.[34]
2NaClO-assisted backwash0.191 mg Cl2·L−1 (optimized)15 min × 8.33 L L·m−2·h−112 h × 6 L·m−2·h−1Synthetic municipal wastewaterMBR (0.01 μm/0.1 m2)● NaClO backflush enhanced the detachment of biopolymers from the fouled membranes and enhanced the denitrification of MBR.
● Low level NaClO-assisted backflush has slight or few adverse effects on sludge and membranes.
[8]
3NaClO-assisted backwash0.953 mg Cl2·L−1 (optimized)30 s × 30 L·m−2·h−19 min × 10 L·m−2·h−1Domestic wastewateranaerobic ceramic MBR (0.08 μm/0.08 m2)● The biodegradability of organics in the wastewater and the microbial activities of biomass were improved with low level of NaClO-assisted backwash.
● High level of NaClO-assisted backwash deteriorated cell metabolism and led to excessive production of cell lytic products.
[9]
4Backwash with chlorinated water3 mg Cl2·L−12 min × 60 L·m−2·h−158 min × 20 L·m−2·h−1Lake water/the Yangtze River water/micro-polluted water/municipal secondary effluentUF (100 kDa/29.0 cm2)● The use of chlorinated-water backwashing decreased the number of microorganisms in the biofouling layer, but increased the level of EPS; thus, the membrane fouling resistance decreased by 8.6%.[10]
5NaClO-assisted backwash95.3 mg Cl2·L−11 h soaking(TMP up to 40 kPa) × 20 L·m−2·h−1Algal-rich waterUF (0.01 μm/0.025 m2)● Among the tested cleaning reagents (NaOH, HCl, EDTA, and NaClO), 95.3 mg Cl2·L−1 NaClO exhibited the best performance (88.4% ± 1.1%) in removing the irreversible fouling resistance.
● The surface morphology of the fouled membrane almost recovered the original state of new membrane after cleaning with NaClO.
[35]
6NaClO-assisted backwash (CEB)284 mg Cl2·L−1 (optimized)5.22 L·m−2·h−1-Synthetic mediumcontained (NH4)2SO4, NaNO2 and some trace elementsMBR (0.01 μm/0.05 m2)● The best cleaning effect was evident at the NaClO concentration of 284 mg Cl2·L−1.[38]
The units of chlorine used in different references were all uniformed to mg Cl2·L−1 in this paper, based on the relationship between NaClO and Cl2: 1 mg·L−1 NaOCl = 0.953 mg Cl2·L−1.
Table 2. UF membrane introduction.
Table 2. UF membrane introduction.
CharacteristicsData
MaterialBlended PES (polyethersulfone)
Pore size–MWCO0.02 µm–200 kDa
Length1.2 m
Internal diameter ID0.9 mm
Number of channels7
Filtration surface 9 m2
Volume of fibers2.0 L
Maximum TMP 2.5 bar
pH tolerant value1–13
Table 3. Feed water quality.
Table 3. Feed water quality.
ParametersValues
E. coli (CFU 100 mL−1)(2.3 ± 1.9) × 104
Enterococci (CFU 100 mL−1)(9.3 ± 5.5) × 103
Anaerobic sulphito-reducers (spores) (CFU 100 mL−1)(9.6 ± 5.1) × 102
Specific F-RNA bacteriophages (PFP 100 mL−1)<30
COD (mgO2·L−1)45 ± 21
TSS (mg·L−1)12.1 ± 8
TOC (mgC·L−1)6.6 ± 0.4
Turbidity (NTU)1.9 ± 0.6
NH4+ (mgN·L−1)3.8 ± 2.4
pH7.5 ± 0.1
Table 4. Physical backwash parameters.
Table 4. Physical backwash parameters.
StepsAB with Cl (RL A1)AB without Cl (RL A2)CB with Cl (RL C1)CB without Cl (RL C2)
Step 1Air injection into the fibers (2 min)Air injection into the fibers (2 min)--
Step 2Decompression before standard backwashDecompression before standard backwashDecompression before standard backwashDecompression before standard backwash
Step 3Backwash top head (31 s)Backwash top head (31 s)Backwash top head (31 s)Backwash top head (31 s)
Step 4Backwash 2 heads (3 s)Backwash 2 heads (3 s)Backwash 2 heads (3 s)Backwash 2 heads (3 s)
Step 5Backwash bottom head (18 s)Backwash bottom head (18 s)Backwash bottom head (18 s)Backwash bottom head (18 s)
Step 6Backwash prefilter (12 s)Backwash prefilter (12 s)Backwash prefilter (12 s)Backwash prefilter (12 s)
Permeate tank (volume)T1 (29.25 L) + T2 (6.75 L)T2 (36 L)T1 (29.25 L) + T2 (6.75 L)T2 (36 L)
Duration184 s184 s64 s64 s
Table 5. Backwash conditions of this study.
Table 5. Backwash conditions of this study.
No.CBCBCBABName
1No ClNo ClNo ClNo ClNNNN
2No ClNo ClNo Cl10 mg Cl2·L−1 ClNNNY
310 mg Cl2·L−1 Cl10 mg Cl2·L−1 Cl10 mg Cl2·L−1 ClNo ClYYYN
410 mg Cl2·L−1 Cl10 mg Cl2·L−1 Cl10 mg Cl2·L−1 Cl10 mg Cl2·L−1 ClYYYY
Table 6. The estimation of NaClO consumption and CT parameters of each condition in 10 years.
Table 6. The estimation of NaClO consumption and CT parameters of each condition in 10 years.
NameEstimated Total CT in 10 Years
(mg Cl2·L−1·h)
CT of Backwash in 10 Years
(mg Cl2·L−1·h)
Equivalent Consumption of NaClO
[gCl2·m−3 (Permeate)]
CEB FrequencyMaximum NaClO CT Value of UF Module
NNNN60,8330272Once per day23,853
mg Cl2·L−1·day
NNNY15,2253058175Once in 5 days
YYYN19,6309490414Once in 6 days
YYYY24,82010,544546Once in 5 days
Table 7. Reversibility ranges of backwash in different conditions.
Table 7. Reversibility ranges of backwash in different conditions.
Condition3rd CBAB
MinMaxMean ± SDMinMaxMean ± SD
NNNN76%102%91 ± 7%92%140%118 ± 12%
NNNY75%104%86 ± 8%98%174%133 ± 16%
YYYN85%125%96 ± 7%81%135%107 ± 12%
YYYY64%114%87 ± 14%85%165%125 ± 21%
Table 8. The turbidity and TOC in different types of backwash water and UF feed and permeate.
Table 8. The turbidity and TOC in different types of backwash water and UF feed and permeate.
Condition Water TypesTurbidity (NTU)TOC (mg·L−1)
All conditionsUF feed1.9 ± 0.96.6 ± 0.4
UF permeate0.4 ± 0.36.3 ± 0.3
NNNNAB20.2 ± 29.3 ± 1
3rd CB10.1 ± 29.4 ± 0.6
NNNYAB 30.9 ± 616.4 ± 2
3rd CB14.1 ± 48.6 ± 0.6
YYYNAB 20.5 ± 318.9 ± 3
3rd CB17.2 ± 217.6 ± 2
YYYYAB 20.2 ± 914.7 ± 6
3rd CB17.0 ± 816.1 ± 0.4
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Yang, J.; Monnot, M.; Ercolei, L.; Moulin, P. Impact of Chlorinated-Assisted Backwash and Air Backwash on Ultrafiltration Fouling Management for Urban Wastewater Tertiary Treatment. Membranes 2021, 11, 733. https://doi.org/10.3390/membranes11100733

AMA Style

Yang J, Monnot M, Ercolei L, Moulin P. Impact of Chlorinated-Assisted Backwash and Air Backwash on Ultrafiltration Fouling Management for Urban Wastewater Tertiary Treatment. Membranes. 2021; 11(10):733. https://doi.org/10.3390/membranes11100733

Chicago/Turabian Style

Yang, Jiaqi, Mathias Monnot, Lionel Ercolei, and Philippe Moulin. 2021. "Impact of Chlorinated-Assisted Backwash and Air Backwash on Ultrafiltration Fouling Management for Urban Wastewater Tertiary Treatment" Membranes 11, no. 10: 733. https://doi.org/10.3390/membranes11100733

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop