Next Article in Journal
Effects of Carbon Doping and Annealing Temperature on Magnetic MnAl Powders and MnAl Polymeric Composites
Next Article in Special Issue
Special Issue on Applied Research on Water Treatment by Onsite Wastewater Management and Agricultural and Stormwater Control Measures at Varying Spatial Scales
Previous Article in Journal
Ru(terpy)-Based Conducting Polymer in Electrochemical Biosensing of Epinephrine
Previous Article in Special Issue
A Rapid UV/Vis Spectrophotometric Method for the Water Quality Monitoring at On-Farm Root Vegetable Pack Houses
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Estimation of Saprolite Thickness Needed to Remove E. coli from Wastewater

Department of Crop & Soil Sciences, North Carolina State University, Box 7620, Raleigh, NC 27695-7620, USA
*
Author to whom correspondence should be addressed.
Appl. Sci. 2021, 11(5), 2066; https://doi.org/10.3390/app11052066
Submission received: 7 January 2021 / Revised: 19 February 2021 / Accepted: 23 February 2021 / Published: 26 February 2021

Abstract

:

Featured Application:

Results of this study can be used by health authorities to set limits on the thickness of saprolite material needed below on-site septic system drainfields in order to remove E. coli from home sewage. Results will also be of interest to field personnel evaluating sites for on-site wastewater disposal.

Abstract

Saprolite, weathered bedrock, is being used to dispose of domestic sewage through septic system drainfields, but the thickness of saprolite needed to remove biological contaminants is unknown for most saprolites. This study developed and tested a simple method for estimating the thickness of saprolite needed below septic drainlines to filter E. coli from wastewater using estimates of the volume of pores that are smaller than the length of the coliform (≤10 μm). Particle size distribution (texture) and water retention data were obtained for 12 different saprolites from the Piedmont and Mountain regions of North Carolina (N.C.). Saprolite textures ranged from clay loam to coarse sand. The volume of pores with diameters ≤10 μm were determined by water retention measurements for each saprolite. The data were used in an equation to estimate the saprolite thickness needed to filter E. coli. The estimated saprolite thicknesses ranged from 36 cm in the clay loam to 113 cm for the coarse sand. The average thickness across all samples was 58 cm. Saprolite thickness estimates increased as silt percentage decreased and as sand percentage and in situ saturated hydraulic conductivity increased. Silt percentage may be most useful for estimating appropriate saprolite thicknesses in the field.

1. Introduction

On-site wastewater management systems (OSWMS), commonly referred to as septic systems, are used to treat and dispose of sewage in areas not served by a municipal sewer system. Approximately 20% of the households in the US, and one-half of those in North Carolina (N.C.), use these systems to manage their domestic sewage on-site [1]. A conventional OSWMS consists of a septic tank and a drainfield [2]. The septic tank provides primary treatment to the sewage by allowing solids to settle and go through anaerobic digestion. The liquid from the septic tank (referred to as wastewater) containing dissolved and suspended organic materials, microbial organisms (e.g., Escherichia coli (E. coli)), and chemical pollutants are dispersed into the soil through a series of trenches in the drainfield [3]. In the unsaturated and aerated environment below the trenches, some pathogenic bacteria are removed through physical filtration, and the anaerobic bacteria typically die off in the aerobic soil environment [4,5].
In N.C. and many other states, most OSWMS are installed at sites with a suitable soil that is at least 60 cm thick [6]. However, in the Southeastern part of the United States (US), saprolite is being increasingly used for OSWMS where soils are thinner. Saprolite (commonly known as rotten rock) is isovolumetrically-weathered bedrock that is porous and friable (similar to soil), but it has had some of its original minerals dissolved and removed, creating pores between the mineral grains that were in the original rock [7,8]. The structure of saprolite is described as “massive-rock controlled,” meaning that the planar voids commonly found between the structural units of soil (i.e., soil peds) are absent in saprolite. Saprolite is found under nearly all soils in the Piedmont and Mountain regions of the Southeastern US and extends from the bottom of the soil solum to solid bedrock [9]. The thickness of saprolite materials is variable and can range from <1 m where bedrock is shallow to over 50 m thick where the bedrock is deep [9].
Coliforms, such as E. coli, can be removed from soil water by: (1) attachment to soil particles, (2) consumption by larger soil microorganisms, or (3) straining by which coliforms are trapped in pore throats that are too small for the organisms to pass through [4]. Bradford et al. [10] showed that straining or filtering was an important mechanism responsible for removing colloid-size particles (<10 μm diameter and including bacteria) from water moving through granular media. They noted that in their study, colloid straining occurred even for particles 0.45 μm in diameter. Colloid straining was controlled by the size of the colloid and the pore sizes in the medium through which the colloid was passing through.
Our previous research has shown that 60 cm of aerated, unsaturated sandy loam saprolite can effectively remove E. coli from simulated wastewater [11]. Similar results have been found for soils of comparable texture [12,13]. Saprolite materials with a sandy loam texture have pores small enough to filter or strain organisms such as E. coli. However, due to the presence of a significant amount of pores, which are >10 μm in diameter, E. coli may not entirely be removed by a 60 cm thick layer of sandy saprolite. Therefore, the main objective of this work was to develop a simple method for estimating the thickness of saprolite needed to filter E. coli from wastewater for textures ranging from clay loam to sand. For this, we propose a unique method for determining the thickness of saprolite in use, which is required for the complete filtration of E. coli and has a volume of pores smaller than 10 μm.

2. Materials and Methods

2.1. Theory

The size and shape of bacterial cells are important parameters that play a key role in particle retention [14]. The typical size of an individual E. coli cell is about 1.1 to 2 μm in width and 2 to 10 μm in length [4,14]. Due to the size and rod-shape of the bacterial cell, E. coli should be filtered when wastewater that is applied to a soil passes through pores that are <10 μm in diameter [15]. The diameter of pores that can hold water as a function of soil water potential can be estimated according to the capillary rise equation by:
D   ( cm ) = 0.3 / h   ( cm )
where D is the diameter of the pore, and h is the soil water pressure head (-cm) [16]. For pores ≤10 μm (0.001 cm) in diameter, the pressure head h is −300 cm. Our previous study [11] showed that a sandy loam saprolite column that was 60 cm long filtered out E. coli that was in a simulated wastewater, which had an E. coli concentration of 1 × 105 CFU/100 mL, while saprolite-filled columns of 30 and 45 cm allowed some E. coli to pass through. We hypothesize that 60 cm of a sandy loam saprolite has a sufficient volume of pores <10 μm in diameter to remove E. coli. Water retention measurements in our previous study showed that the sandy loam saprolite’s water content at a soil water pressure head of −300 cm was 0.28 cm3/cm3, which is equivalent to the volume of the pores having diameters <10 μm in the material. We used this information to develop a general equation for predicting the minimum thickness of saprolite that needs to be used to filter E. coli out of wastewater. The total volume of pores ≤10 μm in diameter (PV10 μm) per unit cross-sectional area of a column of saprolite of thickness T can be estimated from:
P V 10   μm   =   θ 300   × T
where θ−300 is the volumetric water content of saprolite at −300 cm of pressure head as determined from its respective water retention curve. For the sandy loam saprolite material studied previously, where θ−300 was 0.28 cm3/cm3 and T was 60 cm, PV10 μm was 17 cm3/cm2, which we suggest is the minimum volume of pores with diameters of <10 μm needed to filter E. coli from saprolite. Using this value and rearranging Equation (2), we obtain a general equation for estimating the minimum thickness (T) of saprolite needed to remove E. coli from wastewater:
T   ( cm )   =   17   ( cm 3 / cm 2 ) / θ 300   ( cm 3 / cm 2 )
We hypothesize that Equation (3) can be used to estimate the minimum thickness of saprolite material that can be used for on-site wastewater disposal if the water content at −300 cm of pressure head (i.e., θ−300) is known.

2.2. Sampling Sites

Saprolite data were obtained from a previous study that characterized saprolites at 15 different sites in the Piedmont and Mountain regions of N.C. for on-site wastewater management [17]. Due to the lack of a complete data set at some locations, we chose 12 of the sites for this study (Figure 1). The sites were selected to represent a wide range of soil and saprolite conditions that could potentially be used for wastewater disposal. Table 1 presents the location and general soil information for each of the 12 sites. Common rock types from which the saprolite formed are also shown in Table 1. All these saprolites developed from either igneous or metamorphic rock and represent the most common types of saprolite found in N.C. Saprolites from sedimentary rock are not widespread in N.C. and have not been used in OSWMS in the state.
Sites numbered 1–12 were in natural areas, and pits were excavated to describe the soil profile, classify the soil, and collect saprolite samples for characterization. Pits were dug by machine where possible, and by hand otherwise. Pit dimensions varied from site to site but were deep enough to expose the saprolite. Major soil horizons were identified on one wall of the pit to determine the depth to the C horizons, which consisted of saprolite. Disturbed samples were then collected from each horizon identified in the field and stored in plastic bags. Intact (undisturbed) “cores” were collected from the soil surface down to a depth well within the saprolite in close proximity to the observation pit at each site. Core samples were collected with a Giddings hydraulic soil probe (Giddings Equipment Co., Fort Collins, CO, USA) using a 3-inch diameter (7.6 cm) soil sampling tube equipped with a 6.5 or 6.6 cm diameter, quick relief cutting head. All cores were wrapped in plastic and transported to the laboratory in long semi-circular trays to maintain an “undisturbed” state as much as possible. Sites labeled Wake and Knightdale in Table 1 were located on developed homesites that had septic systems. Pits could not be dug at these locations, and so disturbed and undisturbed samples were collected by hand near the septic drainfields at both sites.

2.3. In Situ Saturated Hydraulic Conductivity

Due to variations in soil horizon boundaries, in situ saturated hydraulic conductivity (Ksat) was measured at predetermined depth intervals associated with different horizons around the observation pit at each site by the constant-head well permeameter technique [18]. Due to the presence of rocks, tree roots, and other constraints preventing the boring of an auger hole, Ksat was not measured at all depths/horizons. Moreover, the locations and number of Ksat measurements (10 at four sites; 5 at four sites; 2, 4, 7, and 8 at each of the other four sites) were varied among the sites because of the differences in the landscape conditions and soil profile variations. For most cases, the area around the observation pit was divided into 10- by 10-m square areas, and one measurement for each of the selected depth interval/horizon was conducted within each of these areas. The Compact Constant Head Permeameter [19] was used to measure the steady-state flow rate of water (Q) under about 15 cm of water head (H) in a 6 cm diameter (r = 3 cm) auger hole dug to the desired depth. The Glover equation [20] was used to calculate Ksat.

2.4. Laboratory Analyses

The saprolite cores collected in the field were inspected in the laboratory, and any intact section longer than 8 cm was coated with paraffin to enable handling [21]. The cores were then cut into sections ranging from 7 to 10 cm in length for water retention measurements. Each core was wrapped with two layers of duct tape and again coated with paraffin to secure the material.

2.4.1. Soil Water Retention

Each core was placed in a Buchner funnel fitted with a porous plate and saturated from the bottom to the top to eliminate entrapped air. After saturation, excess water from around the core in the Buchner funnel was removed, and a positive air pressure equal to 5 kPa (equivalent to −50 cm of soil water pressure head) was applied to the funnel [22]. The pressure was maintained for at least 24 h before the total outflow was measured. The air pressure in the funnel was then increased to 10 kPa (equivalent to −100 cm of soil water pressure head), and the outflow was measured at least 24 h later. This step was repeated consecutively after increasing the air pressure in the funnel to 20 and 30 kPa (−200 and −300 cm of soil water pressure heads, respectively). At the end of the measurement, the core was removed from the funnel, and its total mass was determined immediately. To determine the water content of each core, the paraffin and duct tape cover of the sample was removed and cleaned of saprolite material. The weight of the cover was subsequently subtracted from the mass of the total core to obtain the mass of the wet saprolite at the end of water-retention measurement. All saprolite materials from the cores were then placed in an oven and dried at 105 to 110 °C for 24 h. After determining the mass of dry saprolite, the water content at each level of water pressure (i.e., pressure level applied to the funnel) was calculated using the volume of water drained from the core after each pressure increment and the amount of water retained by the core at the end of the measurement. These data were then used to determined θ−300 for each saprolite core.

2.4.2. Other Properties

The disturbed soil samples collected from the horizons in the pits were used for particle size distribution and chemical analyses. These materials were air-dried, crushed, and passed through a 2-mm (No. 10) sieve. Particle size distribution was determined by the pipet method [23] using 10 to 20 g of the air-dried specimen. Each specimen was first treated with 30% H2O2 and heated in a constant temperature bath to remove its organic matter. The mineral particles were then passed through a 300 mesh (0.05 mm) sieve into a 1000 mL cylinder. The sand portion that was retained by the 300 mesh sieve was oven-dried at 105 to 110 °C and fractionated by dry-sieving through a nest of sieves. The silt and clay fractions were determined by sampling the suspension in the 1000 mL cylinder using a 25 mL pipet [23]. The cation exchange capacity (CEC) for each of the disturbed saprolite samples collected from each pit was determined at pH 7 using a procedure for acid soils [24].
Regression analyses were performed to assess the relationships between selected saprolite properties and the calculated saprolite thickness for removing E. coli using R-Studio’s (lm) function (R Studio, Boston MA) for general linear models. Variables in the regression models that had significance values of 0.05 or less were included here.

3. Results and Discussion

3.1. Saprolite Properties

Selected properties of the saprolites studied are shown in Table 2. The sites are listed in increasing estimated thickness of saprolite below septic drainlines needed to remove E. coli from wastewater. Three saprolite horizons were included for Site 5, which had a thick saprolite zone, bringing the total number of samples to 14 for the 12 sites overall. Due to the differing thicknesses in the overlying soil, the depths of saprolite ranged from 50 to 395 cm across sites. Textures ranged from sand to clay loam, and clay percentages ranged from 2 to 30%. In situ Ksat values ranged from 0.7 cm/d (highest clay percentage) to 233 cm/d (highest sand percentage). However, on average, the sites had Ksat values < 10 cm/d.
Cation exchange capacities were generally low (<10 cmol+/kg (Table 2)), suggesting that physical filtration is the major factor in the removal of E. coli rather than adsorption of E. coli onto the negatively-charged mineral particles. Madumathi [25] conducted batch sorption experiments to understand the attachment kinetics of bacteria in the presence of humic acid and clay colloids. Results indicated that the adsorption of bacteria onto porous media was enhanced by the presence of high surface area and high cation exchange capacity clay-textured soil, unlike the materials studied here.
The number of cores analyzed for water retention (for θ−300 calculations) at each site varied from 2 to 22 (Table 2) and depended, in part, on how efficiently the Giddings hydraulic probe collected material. For example, saprolite with a relatively high clay content tended to remain intact in the sampling tube, allowing for more cores to be obtained from the extracted materials. The volume of pores having diameters ≤10 μm ranged from 0.15 to 0.47 cm3/cm3 across the sites. The differences were related to saprolite texture, with the site with the most silt and clay having the largest volume of pores with diameters ≤10 μm, and the site with the greatest sand percentage having the lowest amount of such pores (Table 2).

3.2. Effective Thickness of Saprolite

The thicknesses of saprolite below septic drainlines that would be needed to filter E. coli from wastewater were estimated using the mean values of the pore volume measurements. Thicknesses ranged from 36 to 113 cm and had a mean value of 58 cm across all sites (Table 2). The largest thickness (113 cm) was found for a saprolite consisting of coarse sand with only 4% silt and 5% clay. Coarse sands have a majority of the sand grains in the 0.5 to 1.0 mm diameter class. These particles form relatively large packing pores that E. coli would move through without filtration.
While pore size distribution (from water retention analyses) was used to estimate the saprolite thicknesses needed to filter E. coli from wastewater, such measurements are time-consuming and expensive to conduct. Using other measures related to pore size to estimate the saprolite thicknesses would be more convenient for field personnel to use. As shown in Table 2, saprolite thicknesses for OSWMSs that were < 60 cm had textural classes of loamy sand, sandy loam, and clay loam. Saprolite thicknesses between 68 and 74 cm had textural classes of sand and loamy sand. Despite the apparent relationship between texture and thickness of saprolite for removing E. coli, using textural class alone to determine saprolite thickness in the field may not produce a reasonable value because loamy sand textures showed a broad range in saprolite thicknesses. Correlation coefficients were used to identify other properties that could be used to estimate saprolite thickness (Table 2). Percentages of silt and sand, along with Ksat, had significant r values as shown.
Regression equations relating silt and sand percentages along with Ksat to saprolite thickness are shown in Figure 2. A quadratic relationship between the thickness of saprolite and silt percentage had an R2 of 0.74 (Figure 2A). Silts are defined as particles having diameters between 2 to 50 µm. Fine silts (2 to 10 µm diam.) are close to the size of E. coli and should form packing pores that can filter the organism out of wastewater. Saprolite materials with silt percentages <16% were generally estimated to require >60 cm thickness to filter E. coli (Figure 2A).
A linear relationship was found between sand percentage and saprolite thickness (Figure 2B). The sand relationship contained two samples (site 5′s C4 horizon and site 7, Table 2) with identical values for sand percentage and saprolite thickness, so only 13 data points appear in Figure 2B. A linear relationship was used because quadratic terms were found to be insignificant (i.e., p values >0.05). The R2 value for the sand relationship was lower than the R2 value found for the silt relationship (Figure 2A). Sand may not be as effective a filter for E. coli as silt. The size of sand particles range between 0.050 mm (very fine sand) to 2.00 mm for very coarse sand. Pores between the larger sand particles may be too large to filter E. coli. Finer sands would form smaller pores than the larger fractions and aid in the filtration of E. coli.
The relationship between saprolite thickness and Ksat is shown in Figure 2C. Thirteen values are reported because Site 5′s C4 horizon did not have an in situ Ksat measured. The quadratic (nonlinear) relationship shown in Figure 2C was significant with a relatively high R2 of 0.73. The high R2 was due in large part to one high Ksat value (233 cm/d) as shown for site 10. Without considering site 10, there was no significant relationship between in situ measured Ksat and thickness of saprolite needed for removing E. coli. Based on the data presented in Figure 2C, in situ Ksat measurements do not provide any reasonable estimates of saprolite thickness needed to filter E. coli. We should note that in general, we expect saturated hydraulic conductivity to vary with particle size distribution, with finer textured materials producing smaller Ksat values, but root channels and other macropores may also be present, which could increase Ksat by by-passing the pores created by the packing of sand or silt grains.
While Equation (3) was developed for saprolites, it may be applicable to some soils that do not possess a strong soil structure. For example, using the water-retention data for the sandy loam soil material reported by Stall et al. [13], we estimated the material would require approximately 212 cm of soil thickness to filter E. coli. Nevertheless, experimental data showed that 60 cm would more than enough. However, the sandy loam of Stall et al. [13] had a silt content of 30%, and when using the regression line in Figure 2A, a saprolite thickness of 59 cm would be predicted to be sufficient to remove E. coli for this percentage of silt. This is in line with the experimental results of Stall et al. [13]. The 212 cm thickness value is approximately three times the thickness we computed for the coarse sand texture. The sandy loam material used by Stall et al. [13] was dried and passed through a 2-mm-mesh sieve before packing into cylinders for the experiments. Because water retention was determined using repacked cores, it is likely that the water retention results did not take into account all pores within the soil’s aggregates formed by sieving. On the other hand, the water retention data for the saprolites used in our assessment were obtained using intact cores of non-aggregated saprolite. Non-aggregated materials consist mainly of interparticle pores (i.e., pores between mineral grains), and their volumes are more directly assessed in the water retention measurement procedure.

4. Summary and Conclusions

We developed and used an equation to estimate the thickness of saprolite needed to filter E. coli from wastewater below septic drainlines at 12 field sites. The equation computed the minimum volume of pores < 10 µm, which were small enough to filter E. coli. The equation was derived from results of prior experiments with saprolite columns, which used simulated wastewater having an E. coli concentration of 1 × 105 CFU/100 mL. The saprolite textures evaluated from the 12 sites ranged from coarse sand to clay loam, with most being sandy loam. The estimated thicknesses of saprolite needed to filter E. coli ranged from 35 to 113 cm with a mean of 58 cm. In general, the silt percentage was the best saprolite property to use to estimate in the field the thickness of saprolite required for safe wastewater disposal. Saprolite thickness estimates increased as silt percentage decreased. These estimates pertain to non-aggregated material such as saprolite and may not apply to aggregated (i.e., well structured) soils. The results of this study show that water retention measurements can be used for assessments of the thickness of porous materials needed to filter bacteria such as E. coli from wastewater. More work in the area of wastewater treatment by saprolite is needed to verify the findings of this study under field conditions, particularly for the very sandy saprolites.

Author Contributions

M.J.V. contributed to project conceptualization, methodology selection, validation of data, formal data analysis, writing of the original draft, review and editing of the manuscript, project administration, and funding acquisition. A.A. contributed to project conceptualization, methodology selection, validation of data, writing of the original draft, review and editing of the manuscript, and funding acquisition. T.G. contributed to project conceptualization, writing of the original draft, review and editing of the manuscript, and funding acquisition. All authors have read and agreed to the published version of the manuscript.

Funding

Funding for the research was supplied by the N.C. Department of Health and Human Services, Division of Public Health under Contract No. 00038125.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

All supporting data are included within the manuscript. Authors will supply clarification upon request.

Acknowledgments

Statistical analyses were completed by Christopher Moritz, and his contributions are greatly appreciated.

Conflicts of Interest

The authors have no conflicts of interest.

References

  1. U.S. Census Bureau. American Housing Survey for the United States: 2009, Current Housing Reports. Available online: http://www.census.gov/prod/2011pubs/h150-09.pdf (accessed on 3 July 2020).
  2. U.S. Environmental Protection Agency. On-Site Wastewater Treatment Systems Manual. U.S. EPA, Office of Water: Washington, DC, USA, 2002. [Google Scholar]
  3. Humphrey, C.P.; O’Driscoll, M.A.; Zarate, M.A. Evaluation of on-site wastewater system Escherichia coli contributions to shallow groundwater in coastal North Carolina. Water Sci. Technol. 2011, 63, 789–795. [Google Scholar] [CrossRef] [PubMed]
  4. Foppen, J.W.A.; Schijven, J.F. Evaluation of data from the literature on the transport and survival of Escherichia coli and thermotolerant coliforms in aquifers under saturated conditions. Water Res. 2006, 40, 401–426. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  5. Šarc, A.J.; Kosel, D.; Stopar, D.; Oder, M.; Dular, M. Removal of bacteria Legionella Pneumophila, Escherichia Coli, and Bacillus Subtilis by (super)cavitation. Ultrason. Sonochemistry 2018, 42, 228–236. [Google Scholar] [CrossRef] [PubMed]
  6. N.C. Public Health-Environmental Health Section (NCPHEH). Section 1900-Sewage Treatment and Disposal Systems. 2017. Available online: https://ehs.ncpublichealth.com/oswp/docs/rules/1900-Rules-08-2017.pdf (accessed on 3 July 2020).
  7. Vepraskas, M.J.; Guertal, W.R.; Kleiss, H.J.; Amoozegar, A. Porosity factors that control the hydraulic conductivity of soil-saprolite transition zones. Soil Sci. Soc. Am. J. 1996, 60, 192–199. [Google Scholar] [CrossRef]
  8. Vepraskas, M.J.; Jongmans, A.G.; Hoover, M.T.; Bouma, J. Hydraulic conductivity of saprolite as determined by channels and porous groundmass. Soil Sci. Soc. Am. J. 1991, 55, 932–938. [Google Scholar] [CrossRef]
  9. Daniels, R.B.; Buol, S.W.; Kleiss, H.J.; Ditzler, C.A. Soil Systems in North Carolina Department of Soil Science; Department of Soil Science, NC State University: Raleigh, NC, USA, 1999. [Google Scholar]
  10. Bradford, S.A.; Yates, S.R.; Bettahar, M.; Simunek, J. Physical factors affecting the transport and fate of colloids in saturated porous media. Water Resour. Res. 2002, 38, 1327. [Google Scholar] [CrossRef] [Green Version]
  11. Gardner, T.; Vepraskas, M.J.; Amoozegar, A. Efficiency of saprolite for removing E. coli from simulated wastewater. Water Sci. Technol. 2020, 82, 2545–2551. [Google Scholar] [CrossRef] [PubMed]
  12. Cogger, C.G.; Hajjar, L.M.; Moe, C.L.; Sobsey, M.D. Septic system performance on a coastal barrier island. J. Environ. Qual. 1988, 17, 401–408. [Google Scholar] [CrossRef]
  13. Stall, C.A.; Amoozegar, D.; Lindbo, A.G.; Rashash, D. Transport of E. coli in a sandy soil as impacted by depth to water table. J. Environ. Health 2014, 76, 92–100. [Google Scholar] [PubMed]
  14. Wang, Y.F.; Hammes, F.; Düggelin, T.E. Influence of size, shape and flexibility on bacterial passage through micropore membrane filters. Environ. Sci. Technol. 2008, 42, 6749–6754. [Google Scholar] [CrossRef] [PubMed]
  15. Liao, C.X.; Liang, M.L.; Soupir, M.; Jarboe, L.R. Cellular, particle and environmental parameters influencing attachment in surface waters: A review. J. Appl. Microbiol. 2015, 119, 315–330. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  16. Hillel, D. Introduction to Environmental Soil Physics; Elsevier Academic Press: San Diego, CA, USA, 2004. [Google Scholar]
  17. Amoozegar, A.; Hoover, M.T.; Kleiss, H.J.; Guertal, W.R.; Surbrugg, J.E. Evaluation of Saprolite for On-Site Wastewater Disposal; Water Resources Research Institute, University of North Carolina: Raleigh, NC, USA, 1993; UNC-WRRI-93-279. [Google Scholar]
  18. Amoozegar, A.; Wilson, G.V. Methods for measuring hydraulic conductivity and drainable porosity. In Agricultural Drainage; Skaggs, R.W., van Schilfgaarde, J., Eds.; ASA-CSSA-SSSA: Madison, WI, USA, 1999; Volume 38, pp. 1149–1205. [Google Scholar]
  19. Amoozegar, A. A compact constant-head permeameter for measuring saturated hydraulic conductivity of the vadose zone. Soil Sci. Soc. Am. J. 1989, 53, 1356–1361. [Google Scholar] [CrossRef]
  20. Amoozegar, A. Examination of models for determining saturated hydraulic conductivity by the constant head well permeameter method. Soil Tillage Res. 2020, 200, 104572. [Google Scholar] [CrossRef]
  21. Amoozegar, A. Preparing soil cores collected by a sampling probe for laboratory analysis of soil hydraulic properties. Soil Sci. Soc. Am. J. 1988, 52, 1814–1816. [Google Scholar] [CrossRef]
  22. Dane, J.H.; Hopmans, J.W. Water retention and storage—pressure cell. In Methods of Soil Analysis, Part 4—Physical Methods; Dane, J.H., Topp, G.C., Eds.; Soil Science Social America Journal: Madison, WI, USA, 2002; pp. 684–688. [Google Scholar]
  23. Gee, G.W.; Or, D. Particle-size analysis. In Methods of Soil Analysis, Part 4—Physical Methods; Dane, J.H., Topp, G.C., Eds.; Soil Science Social America Journal: Madison, WI, USA, 2002; pp. 259–293. [Google Scholar]
  24. Rhoades, J.D. Cation exchange capacity. In Methods of Soil Analysis. Part 2-Chemical Methods, 2nd ed.; Page, A.L., Ed.; ASA and SSSA: Madison, WI, USA, 1982; pp. 149–157. [Google Scholar]
  25. Madumathi, G. Transport of E. coli in presence of naturally occurring colloids in saturated porous media. Water Conserv. Sci. Eng. 2017, 2, 153–164. [Google Scholar] [CrossRef] [Green Version]
Figure 1. Map of North Carolina (N.C.) showing locations of sites sampled across the Mountain and Piedmont physiographic regions. Star indicates Raleigh, the capital city of N.C.
Figure 1. Map of North Carolina (N.C.) showing locations of sites sampled across the Mountain and Piedmont physiographic regions. Star indicates Raleigh, the capital city of N.C.
Applsci 11 02066 g001
Figure 2. Relationships between (A) silt percentage, (B) sand percentage, and (C) saturated hydraulic conductivity (Ksat) and saprolite thickness needed to filter E. coli.
Figure 2. Relationships between (A) silt percentage, (B) sand percentage, and (C) saturated hydraulic conductivity (Ksat) and saprolite thickness needed to filter E. coli.
Applsci 11 02066 g002
Table 1. Site number, county location, soil series, soil classification, and common parent rock type for the saprolite at the 12 sites in the Piedmont and Mountain Regions of North Carolina. Site numbers and names are those used by [17].
Table 1. Site number, county location, soil series, soil classification, and common parent rock type for the saprolite at the 12 sites in the Piedmont and Mountain Regions of North Carolina. Site numbers and names are those used by [17].
Site No. CountySoil SeriesSoil ClassificationCommon Rock Types ††
1ChathamEnon, taxadjunctFine, mixed, thermic, Typic HapludalfDiorite
2ChathamVanceClayey, mixed, thermic, Typic HapludultGranite
3CaswellWilkesLoamy, mixed, thermic, Typic HapludalfHornblende schist
5MecklenburgMecklenburgFine, mixed, thermic, Typic HapludalfGabbro
6BurkePacoletClayey, kaolinitic, thermic Typic KanhapludultGranite
7PersonEnon, taxadjunctFine, mixed, thermic, Typic HapludalfDiorite
8PersonMecklenburg, taxadjunctFine, mixed, thermic, Typic PaleudalfGabbro
9JacksonHayesvilleClayey, oxidic, mesic, Typic HapludultGranodiorite
10JacksonWataugaFine-loamy, micaceous, mesic, Typic HapludultMica schist
12CherokeeJunaluskaFine-loamy, mixed, mesic, Typic HapludultSlate
WakeWakeCecilClayey, kaolinitic, thermic Typic KanhapludultMica schist
Knight-daleWakeApplingClayey, kaolinitic, thermic Typic KanhapludultMica schist
Site 4 was omitted because no water retention data were collected. Site No. 11 was located on a steep slope on the side of the mountain in Jackson County, and no intact cores could be collected from the site. One site was located in the Triassic Basin of N.C. with sedimentary parent materials. These sites were not included in our analyses. †† Rock types were obtained from the Official Series Descriptions as reported by the USDA Natural Resources Conservation Service.
Table 2. Selected properties for saprolites studied and estimated thickness of saprolite needed to filter E. coli from wastewater using Equation (3). Correlation coefficients show relationship between a property and estimated saprolite thickness.
Table 2. Selected properties for saprolites studied and estimated thickness of saprolite needed to filter E. coli from wastewater using Equation (3). Correlation coefficients show relationship between a property and estimated saprolite thickness.
Site No.Depth
Range
SandSiltClayTEXTURAL CLASS In Situ KsatCation Exchange CapacityNo. of CoresVolume of Pores
≤ 10 µm Diam. ††
Estimated Saprolite Thickness for OSWMS
cm---------%------- cm/dcmol+/kg cm3/cm3cm
Wake95–120442630Clay loam0.7 4190.47 ± 0.0836
9185–255572122Sandy clay loam211220.38 ± 0.0945
5-C180–14279147Loamy sand36140.37 ± 0.0846
5-C3125–2008315266100.37 ± 0.1546
1276–9073234Sandy loam131140.36 ± 0.0847
8370–395662864129110.34 ± 0.0850
6135–2007321669290.33 ± 0.0552
360–9079165Loamy sand79150.32 ± 0.0553
2195–210622810Sandy loam773150.31 ± 0.0655
1115–21068275271180.28 ± 0.1061
5-C4200–24687112Sand-620.25 ± ND68
750–1508785Loamy sand9960.25 ± 0.1168
Knight.115–1357716752210.23 ± 0.0674
10135–2009145Sand2331150.15 ± 0.06113
r values 0.63 *−0.66 *−0.40--0.80 *−0.16--0.93 *1.0
Geometric mean, number of measurements made per site ranged from 2 to 11 with a mean of 6. †† Mean ± standard deviation. * Indicates r value is significant at the 0.05 level.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Vepraskas, M.J.; Amoozegar, A.; Gardner, T. Estimation of Saprolite Thickness Needed to Remove E. coli from Wastewater. Appl. Sci. 2021, 11, 2066. https://doi.org/10.3390/app11052066

AMA Style

Vepraskas MJ, Amoozegar A, Gardner T. Estimation of Saprolite Thickness Needed to Remove E. coli from Wastewater. Applied Sciences. 2021; 11(5):2066. https://doi.org/10.3390/app11052066

Chicago/Turabian Style

Vepraskas, Michael J., Aziz Amoozegar, and Terrence Gardner. 2021. "Estimation of Saprolite Thickness Needed to Remove E. coli from Wastewater" Applied Sciences 11, no. 5: 2066. https://doi.org/10.3390/app11052066

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop