Next Article in Journal
Cryptosporidium Species and C. parvum Subtypes in Farmed Bamboo Rats
Previous Article in Journal
Screening for Rickettsia, Coxiella and Borrelia Species in Ticks from Queensland, Australia
Previous Article in Special Issue
Biogeography and Environmental Drivers of Legionella pneumophila Abundance and Genotype Composition across the West Bank: Relevance of a Genotype-Based Ecology for Understanding Legionella Occurrence
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Editorial

Editorial Comments to the Special Issue: “Legionella Contamination in Water Environment”

1
Department of Life Sciences and Systems Biology, University of Torino, Via Accademia Albertina 13, 10123 Torino, Italy
2
Department of Public Health and Pediatrics, University of Torino, Piazza Polonia 94, 10126 Torino, Italy
*
Authors to whom correspondence should be addressed.
Pathogens 2020, 9(12), 1017; https://doi.org/10.3390/pathogens9121017
Submission received: 1 December 2020 / Accepted: 1 December 2020 / Published: 2 December 2020
(This article belongs to the Special Issue Legionella Contamination in Water Environment)

1. Introduction

Legionella spp. are ubiquitous microorganisms that are widely distributed in aquatic environments. From these natural reservoirs, this opportunistic pathogen can spread to and colonize artificial aquatic environments [1]. Water systems of large buildings, such as hospitals, thermal baths, hotels, and dental units are often contaminated by legionellae [2,3] and various parameters such as physical, chemical, and microbial building water system characteristics can influence Legionella occurrence [4]. Legionella are intracellular bacteria whose natural hosts are aquatic protozoa in which these bacteria replicate and are protected from harsh environmental conditions [2].
Legionella pneumophila is most frequently associated with human disease (Legionnaire’s disease-LD or Pontiac fever); however, other species, including L. bozemanae, L. dumoffii, and L. longbeachae also cause human infections. The most common way of contagion is via aerosols inhalation containing infectious Legionella from showerheads, certain medical equipment (e.g., respiratory equipment), cooling towers, hydrotherapy equipment, and decorative fountains [5].
A range of physical and chemical disinfection methods have been proposed with the aim of controlling Legionella contamination; however, to date, the most effective procedures have not been defined [6,7]. Therefore, alternative disinfection methods that are effective in controlling the proliferation of Legionella could be useful tools to reduce the risk of the spread of Legionnaires’ disease.
Surveying and monitoring of legionellae in water systems is needed for risk assessment and prevention of legionellosis. However, although the assessment of L. pneumophila in water is typically performed by culture isolation on selective media, it has several limits including the long incubation times and the inability to detect the viable but non-culturable bacteria (VBNC). For this reason, in the last decades, alternative tools for rapid, sensitive, and specific detection of Legionella in water samples have been proposed [7,8]. For the identification of possible sources of contamination/infection, high-resolution genotyping of new isolates (e.g., Sequence Based Typing, Multilocus Variable number of tandem repeats) is needed to correlate environmental with clinical isolates.
In order to increase the knowledge on different aspects of Legionella contamination in the water environment, this Special Issue aims to bring together research studies related to the occurrence of Legionella in water systems of different critical environments (hospital, hotel, large buildings); the role of different factors that can influence the Legionella contamination (e.g., disinfection treatment, water characteristics, plumbing materials, and protozoa presence) as well as the advantages and disadvantages of different methodological approaches were also addressed.

2. Occurrence of Legionella in Large Building Water Systems with Different Methodological Approaches

Many studies have demonstrated that the main sources for LD are the drinking water distribution systems (DWDS) in large buildings such as hospitals and hotels. In particular, the Legionella contamination of hospital water systems posed a high risk for patients and hospital staff. The study of Zayed and collaborators [9] showed a different distribution of the L. pneumophila population in DWDS of eight hospitals throughout the West Bank, highlighting a low concentration of culturable L. pneumophila in water, but a higher prevalence in biofilm. The detection method used influenced the results obtained: in fact, PCR analyses showed a higher detection rate in water and biofilm with respect to culture analyses. The study of environmental isolates is needed for the characterization of the Legionella population and to identify possible sources of infection. The genotyping with Multilocus Variable number of tandem repeats Analysis using 13 loci (MLVA-8(12)) identified 20 genotypes only described for the West Bank and they were attributed to individual groundwater based water supplies. The comparison between the MLVA genotyping and the standard Sequence Based Typing (SBT) methods showed that MLVA was highly consistent with SBT, but showed a higher resolution. This method provides a good basis for detailed studies of the health and water management relevant traits of L. pneumophila in support of a better clinical and DWDS management. The Whole Genome Sequencing (WGS) also provides detailed genetic information about the Legionella strain in large building water system, beyond that obtained from SBT alone, enabling potential subspecies identification, refined taxonomic classification, and genetic profiling for virulence properties [10].
Different studies showed variable rates of contamination and species diversity of Legionella in water systems of other large buildings such as hotels, in non-outbreak situation. However, only little information was available on the molecular diversity of Legionella spp. in hotel settings. In the study of Yakunin and collaborators [11], the results obtained in Israeli Hotels highlighted a relevant Legionella contamination of the DWDS. In 37% of the investigated hotels, Legionella spp. counts exceeded the regulatory threshold (1000 CFU/L). The most frequently contaminated water sources were cooling towers followed by faucet, hot tubes, water lines, and storage tanks. In the same study, as also reported by Zayed et al. [9], several Legionella strains were found to be related to specific geographical regions. This finding could be associated with the water differences between the regions, i.e., physical and chemical properties. The results obtained highlighted the importance of investigating the prevalence and diversity of Legionella strains in hotel buildings in different geographical regions in order to facilitate the risk assessment, surveillance, and control measures of travel-associated Legionnaire’s disease.

3. Prevention and Control of Legionella Contamination

The new revision of the European Drinking Water Directive, such as the WHO guidelines for Drinking Water Quality, suggests the approach of the Water Safety Plan to evaluate the risk associated to the main pathogens involved in waterborne diseases including Legionella. The Italian Guidelines support the development of a risk assessment plan and emphasize the need for an adequate environmental surveillance plan. The study of Mazzotta et al. [12] highlighted, during a Legionella environmental Surveillance Program in different hospitals, the critical role of Surgical and Washing Outlets (SHWO) with Thermostatic Mixer Valves (TMV) in bacterial growth and Health Care-Associated Infections (HAIs) risk. A non significant difference of Legionella contamination between hot and cold samples demonstrated a continuous mixing between two pipelines that create an environment capable of supporting Legionella growth. The characteristics of the mixed water produced are also able to influence the distribution of isolates (L. pneumophila percentage > in hot water). The results obtained underlined the importance of the implementation of environmental surveillance programs with the aim to deepen the critical points.
A wide variety of disinfection techniques (e.g., chemical disinfection, UV, high temperature) can be used for the prevention and control of Legionella contamination in the water network. Girolamini et al. [13] have evaluated that the long term H2O2/Ag+ treatment, a low cost disinfectant easy to dose and not very aggressive on the pipelines, is a good strategy to decrease risk in the hospital, reducing the Legionella contamination level. However, to guarantee the efficiency of the Legionella reduction, it is also necessary to consider the building characteristics, apply an adequate risk assessment plan, increase the monitoring samples size and regulate the dosage in relation to the Legionella loads. These infection prevention strategies can be applied to reduce the risk that is also coming from other contaminated healthcare facilities, such as Dental Unit Water Lines (DUWLs), as reported by Tuvo et al. [14]. In this work, the authors highlighted that an implemented risk management plan, that include filters installation and shock disinfection with a solution of 4% hydrogen peroxide and surfactants, appears to be a promising alternative for decreasing Legionella colonization in DUWLs of Hospital Clinics. In this context, it is important to highlight that, in the dental unit investigated, a water safety plan, a maintenance plan, and a control program were constantly applied, but there was a low adherence to good practices in DU management. A low adherence to the best practice guidance had probably contributed to biofilm proliferation, making necessary measures that are more restrictive.

4. Parameters Influencing the Legionella Occurrence in Building Water Systems

Various parameters such as physical (temperature, pH range, hardness), chemical (disinfectant, pipe materials), microbial (free-living amoeba, protozoa), and characteristics of building water systems can influence Legionella occurrence. In their paper in the present Special Issue, Cullom and co-workers [15] systematically reviewed the literature to critically examine the varied effects of common metallic (copper, iron) and plastic (PVC, PEX) pipe materials on factors influencing opportunistic pathogens such as Legionella growth in drinking water, including the nutrient availability, disinfectant levels, and the composition of the broader microbiome. Plastic pipes demonstrate a lower disinfectant demand while iron pipes exhibit a high disinfectant demand and they can favor the biofilm colonization. Although copper pipes are known for their antimicrobial properties, under some circumstances, copper’s interactions with premise plumbing water chemistry and resident microbes can encourage growth of opportunistic pathogens. Plumbing design, configuration, and operation can be manipulated to control such interactions and health outcomes. The influences of pipe materials on opportunistic pathogen physiology should also be considered, including the possibility of influencing virulence and antibiotic resistance. Moreover, the study of Martin and co-workers [16] demonstrated, under controlled laboratory conditions, the importance of considering interactive effects with flow and pipe materials, particularly with respect to relative water corrosivity and influence on residual chlorine levels, in keeping Legionella levels low. The complex interaction between the various chemical, physical, and microbiological parameters and Legionella contamination is also highlighted by Buse et al. [10]. In their study, negative and positive correlations between Legionella and some water characteristics (pH, temperature, turbidity, chlorine, Heterotrophic plate count, and Vermamoeba vermiformis contamination) were observed and they varied between location and sample types. The authors concluded that future studies would help elucidate ways to effectively manage the risks associated with Legionella exposure within the drinking water distribution systems.
The relationship between L. pneumophila contamination and environmental drivers (e.g., temperature, pH, conductivity, iron, nitrate, nitrite, ammonia, copper, phosphate, zinc, hardness, magnesium, calcium of bulk water) was also investigated by Zayed et al. [17]. Statistical analyses with physico-chemical parameters revealed a decrease of L. pneumophila abundance in water and biofilms with increasing magnesium concentrations. MLVA-genotype analysis of the L. pneumophila isolates and their spatial distribution indicated three niches characterized by distinct physico-chemical parameters and inhabited by specific consortia of genotypes. This study provides novel insights into mechanisms shaping L. pneumophila populations and triggering their abundance leading to an understanding of their genotype-specific niches and ecology in support of improved prevention measures.
Some water quality measurements have been suggested as alternative approaches to predict the Legionella risk for building’s water system instead of directly culturing analysis. However, as reported in the study of Pierre and collaborators [18], a poor correlation and a low positive predictive value between the hot water return line and distal outlet positivity in different buildings was revealed. Moreover, no correlation between Legionella distal site positivity and total bacteria, pH, free chlorine, calcium, magnesium, zinc, manganese, copper, temperature, total organic carbon, or incoming cold-water chlorine concentration was observed. These data confirm that these water quality parameters should not be used alone to determine the building’s Legionella colonization rate and effectiveness of water management programs.

5. Sensitivity and Selectivity of Different Culture Media for Legionella Detection

The plate culture method using specific media usually supplemented with different combinations of antimicrobial selective substances is considered the gold standard for the detection and enumeration of Legionella in water samples. The culture method is generally performed according to standards, such as the International Standard Organization (ISO); in particular, the ISO 11731 is the most used and it has recently been updated. These updates introduced the utilization of different media: (I) the buffered charcoal yeast extract (BCYE) agar, (II) the BCYE with selective supplements (BCYE+AB) containing polymixin B, sodium cefazolin and pimaricin, (III) the highly selective Modified Wadowsky Yee (MWY) agar or, as an alternative, the glycine, vancomycin, polymyxin B, cycloheximide (GVPC) agar. The MWY is the best medium for isolating L. pneumophila from potable water samples, while GVPC was proposed in water samples characterized by high interfering microbial flora. Despite these premises, the study conducted by Scaturro et al. [19] in potable water samples with low interfering microorganisms observed that GVPC was more efficient in detecting Legionella contamination than the BCYE medium. Moreover, no significant difference of Legionella loads (CFU/L) was found between BCYE and GVPC agar plates. Furthermore, the possibility of improving the isolation of Legionella non-pneumophila species on BCYE was not confirmed. These results make questionable the need to utilized BCYE agar plates to analyze potable water samples.
Given that the recovery of Legionella spp. strictly depends on the type of agar being used, quality-assured culture media for water testing are key to consumer safety. In this context, Ditommaso and collaborators [20] reported a comparative assessment of the sensitivity and selectivity of MWY and BCYEα media supplied by two different manufacturers (Xebios Diagnostics and Oxoid) in water samples. Even though the analysis showed an excellent agreement between the recovery rates of the four media tested, the quantitative recovery of Legionella spp. colonies using Xebios media was significantly greater than that achieved by Oxoid media. Furthermore, the sensitivity of detection was significantly higher when samples were plated on MWY Xebios agar, while the selectivity of MWY appeared to be the same regardless of the manufacturer. Finally, the MWY Xebios medium enhanced the recovery of non-pneumophila Legionella species. The results obtained confirmed that culture protocol standardization, as well as quality control of the culture media, are essential to achieve intra- and interlaboratory reproducibility and accuracy.
Although plate culture methods are the gold standard for Legionella detection in water samples, they have high variability in the enumeration, are time consuming, and require significant experience in recognizing Legionella colonies. A promising alternative method is the Legiolert test, a liquid culture method based on bacterial enzyme detection technology, which determines the most probable number (MPN) of L. pneumophila species in water samples. Scaturro et al. [21] highlighted that the plate culture method (MWY) and Legiolert method were comparable and concluded that Legiolert may be considered as a valuable test for the detection and enumeration of L. pneumophila in potable water samples and it can be used as a valid alternative to the traditional plate culture methods.

6. The Role of Protozoa in the Legionella Contamination in Water Distribution System

The implication of interaction with a protozoan host for the control of L. pneumophila as well as the efficacy of potable water disinfection protocols on L. pneumophila and host protozoan are essential and they were reviewed by Nisar and collaborators [22]. The systematic review highlights that protozoan hosts facilitate the intracellular replication and packaging of viable L. pneumophila in infectious vesicles, while cyst-forming protozoans provide protection from prolonged environmental stress. Moreover, the data collected underline the failure of common disinfection procedures to achieve long-term elimination of L. pneumophila and protozoan hosts from potable water. This overview report that the disinfection procedures and protozoan hosts also facilitate biogenesis of viable but non-culturable (VBNC) L. pneumophila, which have been shown to be highly resistant to many water disinfection protocols. However, other studies have demonstrated that all free-living amoebae (FLA) do not exhibit the same behavior when they are exposed to L. pneumophila strains. In fact, the Villaertia magna strain C2c Maki has been demonstrated to eliminate the L. pneumophila serogroup 1 strain Paris. The results obtained in the study of Hasni et al. [23] confirmed that none of the Legionella strains tested (Paris, Philadelphia, and Lens) exhibit intracellular growth and that the V. magna strain C2c Maki decreases the number of internalized L. pneumophila. Thus, these results support the idea that the V. magna strain C2c Maki has a unique behavior in regard to L. pneumophila strains. The non-permissiveness of V. magna C2c Maki toward L. pneumophila strains was confirmed by Mameri et al. [24]. This study demonstrated that V. magna C2c Maki did not increase the expression of different virulence genes (htpX, icmE, lirR, ccmF, gacA, tatB, and lvrE) of L. pneumophila strains in contrast to Acanthamoeba castellanii.

Funding

This research received no external funding.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Cunha, C.B.; Cunha, B.A. Legionnaire’s Disease since Philadelphia: Lessons Learned and Continued Progress. Infect. Dis. Clin. N. Am. 2017, 31, 1–5. [Google Scholar] [CrossRef]
  2. Fields, B.S.; Benson, R.F.; Besser, R.E. Legionella and Legionnaires’ Disease: 25 Years of Investigation. Clin. Microbiol. Rev. 2002, 15, 506–526. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  3. Bonetta, S.; Ferretti, E.; Balocco, F.; Carraro, E. Evaluation of Legionella pneumophila contamination in Italian hotel water systems by quantitative real-time PCR and culture methods. J. Appl. Microbiol. 2010, 108, 1576–1583. [Google Scholar] [CrossRef] [PubMed]
  4. Bargellini, A.; Marchesi, I.; Righi, E.; Ferrari, A.; Cencetti, S.; Borella, P.; Rovesti, S. Parameters predictive of Legionella contamination in hot water systems: Association with trace elements and heterotrophic plate counts. Water Res. 2011, 45, 2315–2321. [Google Scholar] [CrossRef] [PubMed]
  5. Cunha, B.A.; Burillo, A.; Bouza, E. Legionnaires’ disease. Lancet 2016, 387, 376–385. [Google Scholar] [CrossRef]
  6. Lin, Y.E.; Stout, J.E.; Yu, V.L. Controlling Legionella in hospital drinking water: An evidence-based review of disinfection methods. Infect. Control Hosp. Epidemiol. 2011, 32, 166–173. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  7. Bonetta, S.; Pignata, C.; Bonetta, S.; Meucci, L.; Giacosa, D.; Marino, E.; Gorrasi, I.; Gilli, G.; Carraro, E. Effectiveness of a neutral electrolysed oxidising water (NEOW) device in reducing Legionella pneumophila in a water distribution system: A comparison between culture, qPCR and PMA-qPCR detection methods. Chemosphere 2018, 210, 550–556. [Google Scholar] [CrossRef]
  8. Bonetta, S.; Pignata, C.; Bonetta, S.; Meucci, L.; Giacosa, D.; Marino, E.; Gilli, G.; Carraro, E. Viability of Legionella pneumophila in Water Samples: A Comparison of Propidium Monoazide (PMA) Treatment on Membrane Filters and in Liquid. Int. J. Environ. Res. Public Health 2017, 14, 467. [Google Scholar] [CrossRef] [Green Version]
  9. Zayed, A.R.; Pecellin, M.; Salah, A.; Alalam, H.; Butmeh, S.; Steinert, M.; Lesnik, R.; Brettar, I.; Höfle, M.G.; Bitar, D.M. Characterization of Legionella pneumophila Populations by Multilocus Variable Number of Tandem Repeats (MLVA) Genotyping from Drinking Water and Biofilm in Hospitals from Different Regions of the West Bank. Pathogens 2020, 9, 862. [Google Scholar] [CrossRef]
  10. Buse, H.Y.; Morris, B.J.; Gomez-Alvarez, V.; Szabo, J.G.; Hall, J. Legionella Diversity and Spatiotemporal Variation in The Occurrence of Opportunistic Pathogens within a Large Building Water System. Pathogens 2020, 9, 567. [Google Scholar] [CrossRef]
  11. Yakunin, E.; Kostyal, E.; Agmon, V.; Grotto, I.; Valinsky, L.; Moran-Gilad, J. A Snapshot of the Prevalence and Molecular Diversity of Legionella pneumophila in the Water Systems of Israeli Hotels. Pathogens 2020, 9, 414. [Google Scholar] [CrossRef] [PubMed]
  12. Mazzotta, M.; Girolamini, L.; Pascale, M.R.; Lizzadro, J.; Salaris, S.; Dormi, A.; Cristino, S. The Role of Sensor-Activated Faucets in Surgical Handwashing Environment as a Reservoir of Legionella. Pathogens 2020, 9, 446. [Google Scholar] [CrossRef] [PubMed]
  13. Girolamini, L.; Dormi, A.; Pellati, T.; Somaroli, P.; Montanari, D.; Costa, A.; Savelli, F.; Martelli, A.; Grottola, A.; Serpini, G.F.; et al. Advances in Legionella Control by a New Formulation of Hydrogen Peroxide and Silver Salts in a Hospital Hot Water Network. Pathogens 2019, 8, 209. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  14. Tuvo, B.; Totaro, M.; Cristina, M.L.; Spagnolo, A.M.; Di Cave, D.; Profeti, S.; Baggiani, A.; Privitera, G.; Casini, B. Prevention and Control of Legionella and Pseudomonas spp. Colonization in Dental Units. Pathogens 2020, 9, 305. [Google Scholar] [CrossRef] [Green Version]
  15. Cullom, A.C.; Martin, R.L.; Song, Y.; Williams, K.; Williams, A.; Pruden, A.; Edwards, M.A. Critical Review: Propensity of Premise Plumbing Pipe Materials to Enhance or Diminish Growth of Legionella and Other Opportunistic Pathogens. Pathogens 2020, 9, 957. [Google Scholar] [CrossRef]
  16. Martin, R.L.; Strom, O.R.; Pruden, A.; Edwards, M.A. Interactive Effects of Copper Pipe, Stagnation, Corrosion Control, and Disinfectant Residual Influenced Reduction of Legionella pneumophila during Simulations of the Flint Water Crisis. Pathogens 2020, 9, 730. [Google Scholar] [CrossRef]
  17. Zayed, A.R.; Butmeh, S.; Pecellin, M.; Salah, A.; Alalam, H.; Steinert, M.; Höfle, M.G.; Bitar, D.M.; Brettar, I. Biogeography and Environmental Drivers of Legionella pneumophila Abundance and Genotype Composition Across the West Bank: Relevance of a Genotype-Based Ecology for Understanding Legionella Occurrence. Pathogens 2020, 9, 1012. [Google Scholar] [CrossRef]
  18. Pierre, D.; Baron, J.L.; Ma, X.; Sidari, F.P., 3rd; Wagener, M.M.; Stout, J.E. Water Quality as a Predictor of Legionella Positivity of Building Water Systems. Pathogens 2019, 8, 295. [Google Scholar] [CrossRef] [Green Version]
  19. Scaturro, M.; Poznanski, E.; Mupo, M.; Blasior, P.; Seeber, M.; Prast, A.M.; Romanin, E.; Girolamo, A.; Rota, M.C.; Bella, A.; et al. Evaluation of GVPC and BCYE Media for Legionella Detection and Enumeration in Water Samples by ISO 11731: Does Plating on BCYE Medium Really Improve Yield? Pathogens 2020, 9, 757. [Google Scholar] [CrossRef]
  20. Ditommaso, S.; Giacomuzzi, M.; Memoli, G.; Garlasco, J.; Zotti, C.M. Sensitivity and Selectivity of Two Commercially Available Media for Legionella spp. Recovery from Environmental Water Samples. Pathogens 2020, 9, 523. [Google Scholar] [CrossRef]
  21. Scaturro, M.; Buffoni, M.; Girolamo, A.; Cristino, S.; Girolamini, L.; Mazzotta, M.; Sabattini, M.A.B.; Zaccaro, C.M.; Chetti, L.; Laboratory, M.A.N.; et al. Performance of Legiolert Test vs. ISO 11731 to Confirm Legionella pneumophila Contamination in Potable Water Samples. Pathogens 2020, 9, 690. [Google Scholar] [CrossRef]
  22. Nisar, M.A.; Ross, K.; Brown, M.H.; Bentham, R.; Edwards, J. Legionella pneumophila and Protozoan Hosts: Implications for the Control of Hospital and Potable Water Systems. Pathogens 2020, 9, 286. [Google Scholar] [CrossRef] [PubMed]
  23. Hasni, I.; Jarry, A.; Quelard, B.; Carlino, A.; Eberst, J.-B.; Abbe, O.; Demanèche, S. Intracellular Behaviour of Three Legionella pneumophila Strains within Three Amoeba Strains, Including Willaertia magna C2c Maky. Pathogens 2020, 9, 105. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  24. Mameri, R.M.; Bodennec, J.; Bezin, L.; Demanèche, S. Mitigation of Expression of Virulence Genes in Legionella pneumophila Internalized in the Free-Living Amoeba Willaertia magna C2c Maky. Pathogens 2020, 9, 447. [Google Scholar] [CrossRef] [PubMed]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Bonetta, S.; Bonetta, S. Editorial Comments to the Special Issue: “Legionella Contamination in Water Environment”. Pathogens 2020, 9, 1017. https://doi.org/10.3390/pathogens9121017

AMA Style

Bonetta S, Bonetta S. Editorial Comments to the Special Issue: “Legionella Contamination in Water Environment”. Pathogens. 2020; 9(12):1017. https://doi.org/10.3390/pathogens9121017

Chicago/Turabian Style

Bonetta, Silvia, and Sara Bonetta. 2020. "Editorial Comments to the Special Issue: “Legionella Contamination in Water Environment”" Pathogens 9, no. 12: 1017. https://doi.org/10.3390/pathogens9121017

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop