Next Article in Journal
Intelligent Anti-Seismic Foundation: The Role of Fractal Geometry
Next Article in Special Issue
Abrasion and Maintenance of High-Strength Fiber-Reinforced Pervious Concrete
Previous Article in Journal
Identification of Various Execution Modes and Their Respective Risks for Public–Private Partnership (PPP) Infrastructure Projects
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Flexure Strengthening and Analysis Using CFRP Composite and Reactive Powder Concrete

1
Department of Construction Engineering, Chaoyang University of Technology, Taichung 413, Taiwan
2
Department of Civil Engineering, National Central University, Taoyuan 320, Taiwan
*
Authors to whom correspondence should be addressed.
Buildings 2023, 13(8), 1890; https://doi.org/10.3390/buildings13081890
Submission received: 23 June 2023 / Revised: 21 July 2023 / Accepted: 22 July 2023 / Published: 25 July 2023

Abstract

:
There are many cases of carbon fiber-reinforced polymer (CFRP) and reactive powder concrete (RPC) in structural repair and reinforcement, but there are not many related theoretical and experimental discussions. Therefore, the purpose of this research is to focus on the experiment and theoretical calculation of the flexural strengthening of concrete beam specimens. The study was primarily separated into two parts. In the first part, the laboratory tests of flexure strengthening by using CFRP and two reactive powder concretes (RPC1 and RPC2) are used to evaluate the effect of strengthening concrete beams. Secondly, the test value of the maximum flexure failure load of the strengthening specimen using RPC or CFRP and its theoretical value calculated by the transform section method or the ultimate strength method are discussed and compared with their reinforced effect. The test results show that the RPC and CFRP display excellent repair and retrofit potential. The RPC reinforcement material with a thickness of 2 cm and a steel fiber content of 1.0% is approximately equal to the reinforcement effect of three layers of CFRP. In particular, the RPC reinforcement effect is good, and the bonding interface is not damaged. The transform section method could be used to analyze and calculate the maximum flexure failure load of the RPC strengthening concrete beam. The transform section method and ultimate strength method cannot accurately analyze the maximum flexure failure load of the CFRP-strengthening concrete beam.

1. Introduction

For more than thirty years, with the development of concrete technology, traditional concrete has been greatly improved. France, the United States, and Canada are actively developing ultra-high-performance concrete (UHPC)—Reactive Powder Concrete (RPC) [1,2,3,4]. Because RPC does not include coarse aggregates, it was also called high-activity powder mortar in Japan in 1991, or “ultra-high-performance cement-based composite material”. The main reason is that this material not only has a compressive strength of 200 MPa, but also a compressive strength of 800 MPa after a special curing process, as well as ultra-high toughness and durability [5,6,7]. Because the strength, toughness, and durability of RPC far exceeds traditional concrete, it is expected that RPC will be widely used in civil construction and many special projects in the future [8,9,10].
Taiwan is located in an area with frequent earthquakes. Many structures are affected by the earthquake force that causes concrete cracks or spalling, resulting in serious damage to the structures. In addition, many old structures such as bridge structures and nuclear power plants are affected by environmental factors. The impact caused rapid deterioration of the structure, and it was about to face the problem of demolition, reconstruction, or repair and reinforcement, so the maintenance and reinforcement of concrete structures became more and more important; therefore, the demand for repair and reinforcement of concrete structures is expected to increase rapidly in the future.
In recent decades, CFRP has been widely used in structural reinforcement, mainly because of its light weight, relatively ease of installation, high tensile strength, superior chemical properties, corrosion resistance, and fatigue performance, making it an attractive material in engineering structures [11,12,13,14]. In addition, RPC has also shown superior performance in structural reinforcement in recent years [15]. RPC is used as a reinforcing material, and attention must be paid to the bonding between RPC and concrete substrates. Therefore, the roughening treatment of the bonding interface is particularly important. According to the research results of literature [16,17], the shape, arrangement direction, length-to-diameter ratio of steel fibers, and the amount of steel fibers added will affect the strength of concrete. Therefore, it should be ensured that the steel fibers can be evenly distributed during mixing to reduce the entanglement of steel fibers. According to the literature [18,19,20], the test results of the durability of RPC show that it has excellent wear resistance, chemical corrosion resistance, and neutralization resistance. Especially in harsh environments, RPC is used as a reinforcing material, and its strength will not be greatly affected [21,22,23,24].
Reinforced concrete structures or bridge pier structures in Taiwan are often damaged by external forces or the concrete deteriorates due to ambient temperature, humidity, and chemical damage, resulting in insufficient structural bearing capacity. Generally, the reinforced concrete reinforcement method is commonly used to enlarge the column section to increase the bearing capacity, but the quality control of ordinary concrete reinforcement is not easy, and the large internal pores are prone to dry shrinkage and deformation, which reduces the effect of reinforcement and increases the column fracture. In addition, enlarging the section of the column will cause an unsightly appearance and inconvenience in space use [12,13]. Although there are many cases of CFRP and RPC in structural repair and reinforcement, there are not many related theoretical and experimental discussions. In particular, experimental and theoretical studies on flexure strengthening of concrete beams.
Our previous study [15] only evaluated and compared RC beams retrofitted with RPC or CFRP. The main test items and methods are as follows: (1) The feasibility of RPC as a reinforced material was evaluated using basic mechanical tests. (2) Discuss the retrofit effects of making small concrete beams and using RPC or CFRP. The results of the study show that the ultimate load increases by 35% and 56.6% when retrofitting reinforced concrete beam members with RPC or CFRP, respectively. However, theoretical analysis and verification have not been performed. Therefore, the purpose of this study is to perform experiments and basic theoretical calculations on the flexural strengthening of concrete beam specimens reinforced with CFRP and RPC. This continuous research can provide a reference for the reinforcement technology and design of concrete structures.

2. Materials and Methods

This study uses CFRP composite or RPC material for the flexural strengthening of concrete beams. The main test was divided into two parts. Firstly, the flexural strength properties of RPC with different fiber contents are tested. Second, ordinary concrete beam specimens undergo flexural strengthening with two kinds of RPCs (fiber content 0.5% and 1.0%) or CFRP patches. More specifically, this was done to test their flexural strength, compare the strengthening effect of the two reinforcing materials, and discuss the calculation and experimental value of the theoretical value of the flexural strength.

2.1. Raw Material

The cements used in RPC in this study are Portland Type I and Type II cements produced by Taiwan Cement Company. The heat generation rate is relatively slow. In Taiwan’s highly corrosive environment, Type II cement has the characteristics of moderate sulphate resistance, which contributes to the durability of the material. Its chemical composition and properties are shown in Table 1. The silica fume is imported BIAXIS SF, with a particle size of 0.1–0.2 μm. Its chemical composition and physical properties are shown in Table 1. Portland Type II cement has a lower heat of hydration than Type I cement, as well as low alkali content and moderate sulphate resistance. Silica fume, a fine powder with high silicon dioxide content (SiO2 content above 90%), can be used as a high-strength concrete admixture to replace part of the cement.
The reinforced concrete beam specimens were ordinary concrete (PC) with a design compressive strength of 20 MPa at 28 days of age. PC uses type I cement, and RPC1 and RPC2 use type II cement. The Mix design of RPCs and PC is shown in Table 2. The steel fiber content of RPC1 and RPC2 is 0.5% and 1.0% of the volume content, respectively. The mechanical behavior of RPC is closely related to the amount of steel fiber content. Its flexural strength tends to increase significantly with the increase of steel fiber content. However, the higher the fiber content, the higher the cost and tendency to cause balling. Therefore, choosing 0.5% and 1.0% content is more economical and can maintain the workability. The copper-plated fiber on the surface of the steel fiber is golden yellow, and it is a straight steel fiber. It adopts Dramix OL 13/.20HC steel fiber produced in Belgium, with a density of 7850 kg/m3, a diameter of 0.25 mm, a length of 13 mm, and an aspect ratio of 65.
A company in Taichung provided the CFRP used in this test and the model was ordinary AEC200. The physical properties and tests of CFRP materials are shown in Table 3. CFRP material is a commonly used forward-looking repair and strengthening material. The elastic modulus and tensile strength of the CFRP sheet are 230,456 MPa and 470 MPa, respectively. A company in Taichung also provided epoxy resin. Epoxy resin is divided into two types: main agent and hardener. Its physical properties and test indicators are shown in Table 2. Epoxy resin was prepared according to the weight ratio of the main agent:curing agent = 2:1, stirred with a mixer, made into the two mixes evenly and applied on the concrete surface, and pressed closely on the carbon fiber board to strengthen the concrete components.

2.2. Test Specimens and Methods

The preparation and manufacture of the concrete beam specimens in this study are complicated. Firstly, after the concrete beam specimen was cured for 28 days, the PC beam specimen was reinforced with RPC and CFRP materials, respectively. Among them, RPC adopts two mixed proportions (RPC1 fiber content 0.5% and RPC2 fiber content 1.0%). Seven days after the reinforcement was completed, the bending test of the concrete beam specimen was carried out. At the end of the experiment, the calculation and experimental value of the theoretical value of the flexural strength of the reinforced material can be checked. The composite concrete sample after reinforcement was calculated by the conversion section method or ultimate stress method of material mechanics. It can withstand the maximum damage load and compare the difference between the calculated maximum damage load theoretical value and the experimental value.

2.2.1. Test Plan

The test plan of this study is mainly divided into two parts. The first is PC concrete sample production. After the PC concrete sample is cured, it will be reinforced with CFRP and RPC materials.
The second is to carry out the concrete beam flexural test, and to reinforce the RPC and CFRP materials with different contents. Bending loads tested the effect of PC concrete samples modified with RPC and CFRP materials. The test flowchart of the beam retrofitted with CFRP and CFRP is shown in Figure 1. Samples of three different composite laminates named CFRP1, CFRP2, and CFRP3 were tested. They are respectively coated with 1 to 3 layers of CFRP sheet with a unit area weight of 200 g/m2 and coated with Guosen epoxy resin on both sides. Each of these layers is approximately 0.5 mm thick.

2.2.2. Fabrication of Concrete Samples Retrofitted with RPC or CFRP

The fabrication of concrete samples retrofitted with RPC or CFRP can be explained in the following:
(1)
Fabrication of concrete samples retrofitted with CFRP
The concrete sample is made by PC concrete into a 10 × 10 × 35 cm bending test specimen. After removing the formwork, it is cured in saturated lime water for 14 days. After curing, the test specimen is placed in the air for more than 24 h, and the specimen is dried. After that, the CFRP patch can be applied; the flexural test specimen is covered with CFRP patch as shown in Figure 2, which is divided into one layer, two layers, and three layers of reinforcement. The test age of the specimen was 14 days after the CFRP coating was completed, and the flexural strength test was carried out.
(2)
Fabrication of concrete samples retrofitted with RPC
In the production of the concrete sample retrofitted with RPC, the specimen of 8 × 10 × 35 cm or 9 × 10 × 35 cm is poured with PC concrete. After the formwork is removed, it is cured in saturated lime water for 14 days. A layer of 2 × 10 × 35 cm or 1 × 10 × 35 cm RPC1 or RPC2 was poured on top of the specimen to bond it into a 10 × 10 × 35 cm concrete sample, as shown in Figure 2.
After removing the mould from the hard solid, it was put in water at 90 °C for curing. The test age of the test specimen is 14 days after the RPC pouring is completed, and then the flexural strength test is carried out.

3. Results and Discussion

The test results and discussion of this study include (1) RPC flexural strength test, (2) RPC and CFRP concrete beam reinforcement tests, (3) theoretical calculation and experiment of bending strength of reinforced PC beams and discussion of the differences in their reinforcement effects, as well as checking the hardness value of early CFRP above 70.

3.1. Flexural Strength of RPC

Figure 3 shows the flexural strength test results of RPC concrete with 0%, 0.5%, 1%, and 1.5% steel fibers respectively. It can be clearly seen from the figure that the flexural strength tends to increase significantly with the increase of steel fiber content. When the steel fiber content increases to 1.5%, its flexural strength is about 2 times higher than that without steel fiber, which shows that the addition of steel fiber can effectively improve the tensile strength and toughness of concrete. The randomly dispersed steel fibers in the RPC concrete matrix disperse the stress and confine the concrete matrix. Possibly due to this mechanism, steel fiber reinforced concrete has improved flexural strength and ductility, and increased energy absorption capacity. The steel fiber parameters that affect the mechanical properties of RPC include volume fraction, size, shape, orientation and distribution, flexural strength and tensile strength, etc., which deserve further study [17].
When the ordinary concrete specimen is subjected to the three-point bending test, the specimen will be broken into two parts from the middle loading point, while the RPC concrete increases the toughness due to the addition of steel fibers. There will be cracks, the cracks will slowly extend upwards, and the opening of the cracks will gradually become larger. At this time, you can clearly see the situation where the steel fibers are pulled out in the cracks. When the bending test specimen is damaged, the steel fiber has the binding effect, so that the test body will not be broken into two parts suddenly. Therefore, it can be clearly seen from the results of the bending test that the improvement of the brittleness of concrete by adding steel fibers can be achieved. This can improve the flexural strength of concrete, avoid concrete cracks, and increase the toughness and earthquake resistance of structures. In this study, due to the consideration of the construction property and the cost of steel fiber materials, the fiber content of 0.5% and 1% of the RPC concretes was used in the concrete reinforcement test, which is RPC1 and RPC2 in Table 2, respectively.

3.2. Concrete Beam Reinforcement

Concrete beam reinforcement test is to reinforce PC beam with CFRP patch and RPC, and then test the reinforcement effect of its flexural strength; CFRP patch reinforcement is divided into one layer, two layers, and three layers of CFRP patch on PC beam specimen. For RPC reinforcement, 1 cm and 2 cm thick RPC1 or RPC2 were directly poured on the PC beam specimen, as shown in Figure 2.

3.2.1. Concrete Beams Reinforced with CFRP

It can be seen from Table 4 that the flexural strength of the beam specimen reinforced with one layer of CFRP is about 65% higher than that of the unreinforced (control group), and the flexural strength of the reinforced two-layer CFRP is about 110% higher than that of the unreinforced, the flexural strength of the reinforced three-layer CFRP is about 160% higher than that of the unreinforced one. It is obvious that flexural strength increases with the increase of the number of reinforced layers. When the flexural specimen reinforced by CFRP is damaged, there will be cracks at the loading place of the beam specimen. When the crack becomes larger, it will continue to extend to the bond interface between the CFRP and the concrete, and finally break from the weaker bond interface, causing the specimen to break into two pieces. The beam specimen on the other side is still tightly bonded to the CFRP, while the broken concrete specimen only had damage at the bonding interface with the CFRP, and the CFRP patch did not break, as shown in Figure 4.

3.2.2. Concrete Beams Reinforced with RPC

The strength development of the beam concrete test specimen reinforced with RPC can be seen from Table 4. With the increase of steel fiber content and repair thickness, its strength increases significantly. Among them, the reinforcement of RPC2 with a thickness of 1 cm is about equal to that of a coating layer of CFRP, reinforced with 2 cm thick RPC1 is also approximately equal to covering two layers of CFRP. Reinforcing with 2 cm thick RPC2 is also approximately equal to covering three layers of CFRP, showing that RPC-reinforced concrete can also obtain good reinforcement effect, as shown in Figure 5.
When the CFRP-reinforced compression test specimen fails, it will produce brittle failure without warning, and with the increase of the number of reinforcement layers, the brittle failure of the test specimen is more obvious [11,12,13,14]. Therefore, this phenomenon should be avoided in the structural reinforcement design. Concrete reinforcement mainly focuses on the bonding problem of the interface between new and old materials and the effect of reinforcement. After observing the damage of the flexural test specimen reinforced with CFRP, it was found that the first and second layers of CFRP reinforcement were finally damaged due to cracks at the bonding interface. Therefore, When CFRPs are used to reinforce beam members, the ends of CFRPs can be anchored with chemical bolts or stiffeners to increase the effect of reinforcement. While RPC is used to strengthen the flexural specimen, it may be broken into two pieces, but RPC can exert excellent bond strength with the concrete matrix, so using RPC as a reinforced material for concrete components can indeed achieve reinforcement effects.

3.3. Theoretical Calculation and Analysis of Bending Strength of Reinforced PC Beams

Here, we calculate the maximum failure load that the reinforced composite beam can withstand by the conversion section method or ultimate stress method of material mechanics and compare the difference between the calculated maximum failure load theoretical value and the experimental value. See Appendix A for the theoretical formulas of material mechanics.

3.3.1. Comparison of Experimental and Theoretical Values of PC Beams Reinforced with RPC

Reinforce the 10 × 10 × 35 cm PC beam with 1 cm thick RPC1, and the span length L = 30 cm. Calculate the maximum failure load P when the PC beam is subjected to a three-point bending test. The basic properties of concrete substrates and reinforcing materials are as follows:
  • PC beam: elastic modulus E1 = 2.41 × 105 kg/cm2, compressive strength σ1 = 347 kgf/cm2, flexural strength σ2 = 53 kgf/cm2, oblique shear strength τ = 117 kgf/cm2
  • RPC1: elastic modulus E2 = 3.01 × 105 kg/cm2, flexural strength σ3 = 201 kgf/cm2
The shear force diagram and bending moment diagram of a simply supported beam subjected to a P force are as shown in Figure 6.
The converted section method (shown in Figure 7) is used to calculate the internal stress of the composite beam as follows:
n = E 2 E 1 = 3.01 × 10 5 2.41 × 10 5 = 1.25
y ¯ = E 1 h 1 2 + 2 E 1 h 1 h 2 + E 2 h 2 2 2 ( E 1 h 1 + E 2 h 2 ) = ( 2.41 × 10 5 ) × ( 9 ) 2 + 2 ( 2.41 × 10 5 × 9 × 1 ) + ( 3.01 × 10 5 ) × ( 1 ) 2 2 ( 2.41 × 10 5 × 9 + 3.01 × 10 5 × 1 ) = 4.89   cm
I = 1 3 × 10 × ( 5.11 ) 3 + 1 3 × 12.5 × ( 4.89 ) 3 1 3 × 2.5 × ( 3.89 ) 3 = 882.9   cm 4
PC concrete subjected to maximum compressive stress: σ 1 = M 1 y 1 I
M 1 = σ 1 I y 1 = 347 × 882.9 5.11 = 59,954.3   kg cm
PC concrete subjected to maximum tensile stress: σ 2 = M 2 y 2 I
M 2 = σ 2 I y 2 = 53 × 882.9 3.89 = 12,029.2   kg cm
RPC1 concrete subjected to maximum tensile stress: σ 3 = n M 3 y ¯ I
M 3 = σ 3 I n y ¯ = 201 × 882.9 1.25 × 4.89 = 29,032.8   kg cm
Shear stress at the bonding interface: τ = V Q I b
117 = P 2 × 54.875 882.9 × 10 P = 117 × 882.9 × 10 × 2 54.875 = 37,648.9   kg
The maximum failure load is controlled when the PC concrete is subjected to the maximum tensile stress.
M = P L 4 = 12,029.2
Theoretical value P = 4 M L = 4 × 12,029.2 30 = 1603.9   kg
The experimental value P = 1658.94 kg.
RPC1 reinforced 1 cm increases the strength by 34.9% compared with the unreinforced theoretical value, however, the strength of the experimental value increased by 39.5%.
The above results show that the theoretical maximum breaking load of the reinforced bending test body is P = 1603.9 kgf, which is 34.9% higher than that of the unreinforced bending strength. The bending strength increases by 39.5%, and the maximum failure load of the experimental value is very close to the calculated theoretical value.
In addition, the calculation results are shown in Table 5 for the increase ratio of the maximum failure load theoretical value of the 2 cm thick RPC1 reinforced PC beam, the 1 cm thick RPC2 reinforced PC beam, and the 2 cm thick RPC2 reinforced PC beam. Since the RPC-reinforced concrete is analyzed by the internal stress of the beam in material mechanics, the theoretical value and the experimental value of the maximum failure load can obtain similar results. Therefore, this method is suitable for evaluating the PC beams reinforced with RPC.

3.3.2. Comparison of Experimental and Theoretical Values of PC Beams Reinforced with CFRP

The theoretical value of the maximum failure load of the CFRP-reinforced PC beam was calculated using the conversion section method and the ultimate stress method of material mechanics. A 10 × 10 × 35 cm PC beam is reinforced with a layer of CFRP patch, and the span length L = 30 cm. The maximum failure load P is calculated when the PC beam is subjected to a three-point bending test. The basic properties of concrete substrates and reinforcing materials are as follows:
  • PC beam: elastic modulus E1 = 2.41 × 105 kg/cm2, compressive strength σ1 = 347 kgf/cm2, flexural strength σ2 = 53 kgf/cm2, oblique shear strength τ = 117 kgf/cm2
  • CFRP1: elastic modulus E2 = 7.4 × 105 kg/cm2, flexural strength σ3 = 7800 kgf/cm2, oblique shear strength τ = 100 kgf/cm2, thickness t = 0.3 mm.
The shear force diagram and bending moment diagram of a simply supported beam subjected to a P force are as shown in Figure 6.
(1)
Using the converted section method (shown in Figure 8) to calculate the internal stress of the composite beam is as follows:
n = E 2 E 1 = 7.4 × 10 5 2.41 × 10 5 = 3.07
y ¯ = E 1 h 1 2 + 2 E 1 h 1 h 2 + E 2 h 2 2 2 ( E 1 h 1 + E 2 h 2 ) = ( 2.41 × 10 5 ) × ( 10 ) 2 + 2 ( 2.41 × 10 5 × 10 × 0.03 ) + ( 7.4 × 10 5 ) × ( 0.03 ) 2 2 ( 2.41 × 10 5 × 10 + 7.4 × 10 5 × 0.03 ) = 4.98   cm
I = 1 3 × 10 × ( 5.05 ) 3 + 1 3 × 30.7 × ( 4.98 ) 3 1 3 × 20.7 × ( 4.95 ) 3 = 856.3   cm 4
PC concrete subjected to maximum compressive stress: σ 1 = M 1 y 1 I
M 1 = σ 1 I y 1 = 347 × 856.3 5.05 = 58,838.8   kg cm
PC concrete subjected to maximum tensile stress: σ 2 = M 2 y 2 I
M 2 = σ 2 I y 2 = 53 × 856.3 4.95 = 9168.5   kg cm
CFRP1 subjected to maximum tensile stress: σ 3 = n M 3 y ¯ I
M 3 = σ 3 I n y ¯ = 7800 × 856.3 3.07 × 4.98 = 436,870.6   kg cm
Shear stress at the bonding interface: τ = V Q I b
100 = P 2 × 4.57 856.3 × 10 P = 100 × 856.3 × 10 × 2 4.57 = 374,748.4   kg
The maximum failure load is controlled when the PC concrete is subjected to the maximum tensile stress.
M = P L 4
Theoretical value P = 4 M L = 4 × 9168.5 30 = 1222.5   kg .
Experimental value P = 1990.3 kg.
CFRP1 reinforced 1 layer increased the strength by 2.8% compared to the unreinforced theoretical value, however, the strength of the experimental value increased by 67.3%.
(2)
The ultimate stress method (shown in Figure 9) calculates the internal stress of the composite beam:
Assume that the concrete cannot withstand tensile stress. Concrete strain ε c = 0.003 .
Find the neutral axis position:
0.003 x = ε x d x
ε x x = 0.003 d 0.003 x
x = 0.003 d ε x + 0.003 = 0.003 d σ E + 0.003 = 0.003 × 10.03 7800 7.4 × 10 5 + 0.003 = 2.22   cm
T = σ A s = 7800 × 10 × 0.03 = 2340   kgf
10.03 − 2.22 = 7.81 cm
M = 7.81 × 2340 = 18,275.4 kgf·cm
M = P L 4
Theoretical value P = 4 × 18275.4 30 = 2436.7   kgf .
Experimental value P = 1990 kgf.
CFRP1 reinforced 1 layer increased the strength by 104.9% compared to the unreinforced theoretical value, however, the strength of the experimental value increased by 67.3%. The theoretical calculation and experimental results of CFRP reinforcement are shown in Table 5. It is obvious that the theoretical values of one-layer, two-layer, and three-layer CFRPs are all overestimated. The analysis of the internal stress of the beam by the conversion section method and the ultimate stress method cannot correctly evaluate the effect of CFRP reinforcement. There is such a large difference between the theoretical value and the experimental value, which may be due to: (a) The CFRP patch has a higher tensile strength than the bonded interface. (b) When the concrete has cracks at the loading point, the concrete can hardly bear the tensile force at this time, and the tensile force is borne by the bonding interface between the CFRP patch and the concrete. (c) The test load is jointly borne by the CFRP and the concrete, and the CFRP can withstand larger deformation than the concrete. (d) When the tensile force is greater than the bond strength that the interface can withstand, the bonding interface between the concrete and the CFRP will fall off and be damaged, but the CFRP will not be torn [15,25]. The interface bonding between CFRP and concrete plays an important role in the reinforcement of concrete members using CFRP [25]. In addition, factors such as bending capacity, ductility, and maximum deflection should be considered. An important parameter in these analyses is the value of the elongation at failure of the CFRP composite, which can lead to premature failure of the “beam-bond-reinforcement” system [26].
The theoretical value obtained by the conversion section method is because the concrete is damaged by tension, and the strength provided by the bonding interface between the CFRP and the concrete is not considered after the concrete is damaged. Therefore, the calculated theoretical value will be significantly lower than the experimental value. The theoretical value obtained by the ultimate stress method is based on the assumption that the concrete cannot bear the tensile force and the CFRP patch has reached a subdued state, which is different from the phenomenon observed in the experiment, so the theoretical value obtained by the ultimate stress method will be higher [13]. Xiang et al. [27] related study on the calculation method of flexural strength of damaged reinforced concrete beams strengthened by CFRP sheets, and the section analysis method was used to analyse the flexural strength of damaged beams. After the effective strain equation of the CFRP sheet is recommended, the experimental results can be verified.
ACI PRC 440.2 [28] provides guidance for the selection, design and installation of FRP systems for external reinforcement of concrete structures. Ross et al. [29] also proposed a practical design method, which agrees well with the experimental results. To evaluate the strength enhancement provided by the FRP panels, an inelastic section analysis procedure was developed that can accurately predict the load–displacement response of the modified beam.

4. Conclusions

In this study, the reinforced PC beam test was carried out for RPC and CFRP materials, the flexural strength was tested, and the theoretical and experimental values of the flexural strength of different reinforced materials were discussed. The main research results are as follows:
(1)
According to the results of the bending test, the flexural strength of RPC concrete has a tendency to increase significantly with the increase of steel fiber content. When the steel fiber content increases to 1.5%, its flexural strength is about 2 times, so adding steel fiber can effectively improve the tensile strength and toughness of concrete.
(2)
The flexural strength of CFRP-reinforced concrete beam specimens can be increased by 67.3% with one layer of CFRP, 118.4% with two layers of CFRP, and 160.8% with three layers of CFRP. It shows that CFRP-reinforced concrete can obtain a good reinforcing effect, and the flexural strength is significantly improved with the increase of CFRP-reinforced layers.
(3)
The flexural strength of the concrete beam specimen reinforced with RPC increases significantly with the increase of steel fiber content and repair thickness. Among them, RPC reinforcement with a thickness of 1 cm and a steel fiber content of 1% is approximately equal to a layer of CFRP, and an RPC reinforcement with a thickness of 2 cm of 0.5% steel fiber is also approximately equal to a two-layer CFRP coating. The RPC reinforcement with a thickness of 2 cm and a steel fiber content of 1.0% is approximately equal to that of three layers of CFRP.
(4)
The RPC reinforcement can be used to analyze the internal stress of the beam using the conversion section method of material mechanics. The theoretical value and experimental value of the maximum failure load obtained can obtain similar results. Therefore, this method is suitable for evaluating the effectiveness of RPC-reinforced concrete beams.
(5)
Analyzing the internal stress with the conversion section method and ultimate stress method of material mechanics cannot correctly evaluate the effectiveness of CFRP-reinforced concrete beams.
(6)
Due to the high cost of experimental testing, future research directions could consider developing methods to accurately predict the behavior of unreinforced and strengthened composite beams.

Author Contributions

Investigation, Y.-C.W. and M.-G.L.; Writing—original draft, M.-G.L. and Y.-C.K.; Analysis, or interpretation of data—M.-G.L., W.-C.W. and Y.-S.H.; Writing—review & editing, W.-C.W. and C.-H.W. All authors have read and agreed to the published version of the manuscript.

Funding

The funding support provided by the Ministry of Science and Technology of Taiwan, grant number [111-2121-M-324-003].

Data Availability Statement

Not applicable.

Acknowledgments

The authors acknowledge the financial support provided by the Ministry of Science and Technology of Taiwan, grant number [111-2121-M-324-003].

Conflicts of Interest

The authors declare no conflict of interest.

Appendix A

Theoretical formulas:
    n = E 2 E 1
  y _ = E 1 h 1 2 + 2 E 1 h 1 h 2 + E 2 h 2 2 2 E 1 h 1 + E 2 h 2
    I = 1 3 b h 3 + 1 3 b h 3 1 3 b h 3
    σ 1 = M 1 y 1 I
    M 1 = σ 1 I y 1
    σ 2 = M 2 y 2 I
    M 2 = σ 2 I y 2
    σ 3 = n M 3 y _ I
    M 3 = σ 3 I n y _
    τ = V Q I b
    M = P L 4
    P = 4 M L
ε c x = ε x d x
    ε x x = 0.003 d 0.003 x
    x = 0.003 d ε x + 0.003 = 0.003 d σ E + 0.003
T = σ A s

Nomenclature

nelastic modulus ratio
E1elastic modulus of PC
E2elastic modulus of reinforcing material
bwidth of beam rectangular section, mm
hheight of beam rectangular section, mm
h1height of PC beam section, mm
h2height of reinforcing material beam section, mm
ydistance from neutral axis to outer surface of beam, mm
σ1maximum compressive stress of PC
σ2maximum tensile stress of PC
σ3maximum tensile stress of reinforcing material
τ shear stress at the bonding interface
xdepth of the equivalent rectangular stress block, mm
ε c concrete strain
ε x strain of reinforcing material
Imoment of inertia
M 1 bending moment of maximum compressive stress of PC
M 2 bending moment of maximum tensile stress of PC
M 3 bending moment of maximum tensile stress of reinforcing material
Astotal area of tensile reinforcement (CFRP), mm2

References

  1. Dugat, J.; Roux, N.; Bernier, G. Mechanical properties of reactive powder concretes. Mater. Struct. 1996, 29, 233–240. [Google Scholar] [CrossRef]
  2. Lee, M.; Chiu, C.; Wang, Y. The Study of Bond Strength and Bond Durability of Reactive Powder Concrete. J. ASTM Int. 2005, 2, 104–113. [Google Scholar] [CrossRef]
  3. Richard, P.; Cheyrezy, M. Composition of reactive powder concretes. Cem. Concr. Res. 1995, 25, 1501–1511. [Google Scholar] [CrossRef]
  4. Lee, M.; Wang, Y.; Chiu, C. A preliminary study of reactive powder concrete as a new repair material. Constr. Build. Mater. 2007, 21, 182–189. [Google Scholar] [CrossRef]
  5. Bonneau, O.; Lachemi, M.; Dallaire, E.; Dugat, J.; Aitcin, P.C. Mechanical Properties and Durability of Two Industrial Reactive Powder Concretes. ACI Mater. J. 1997, 94, 286–290. [Google Scholar]
  6. Graybeal, B.A. Compressive behavior of ultra-high-performance fiber-reinforced concrete. ACI Mater. J. 2007, 104, 146–152. [Google Scholar]
  7. Wu, Z.; Shi, C.; Khayat, K.H. Investigation of mechanical properties and shrinkage of ultra-high performance concrete: Influence of steel fiber content and shape. Compos. Part B Eng. 2019, 174, 107021. [Google Scholar] [CrossRef]
  8. Skazlic, M.; Bjegovic, D.; Serdar, M. Influence of test specimens’ geometry on compressive strength of ultra-high-performance concrete. In Proceedings of the 2nd International Symposium on Ultra-High-Performance Concrete 2008, Kassel, Germany, 5–7 March 2008; pp. 295–301. [Google Scholar]
  9. Magureanu, C.; Sosa, I.; Negrutiu, C.; Heghes, B. Mechanical properties and durability of ultra-high-performance concrete. ACI Mater J. 2012, 109, 177–183. [Google Scholar]
  10. Kang, S.T.; Choi, J.I.; Koh, K.T.; Lee, K.S.; Lee, B.Y. Hybrid effects of steel fiber and microfiber on the tensile behaviour of ultra-high-performance concrete. Compos. Struct. 2016, 145, 37–42. [Google Scholar] [CrossRef]
  11. Lee, M.; Huang, Y.; Kan, Y.; Wang, Y.; Chen, Y.; Kao, S. Experimental study on durability of CFRP-strengthened wood members. J. Mater. Res. Technol. 2023, 24, 3704–3716. [Google Scholar] [CrossRef]
  12. Qiang, X.; Chen, L.; Jiang, X. Experimental and theoretical study on flexural behavior of steel–concrete composite beams strengthened by CFRP plates with unbonded retrofit systems. Compos. Struct. 2023, 309, 116763. [Google Scholar] [CrossRef]
  13. Zhang, Y.; Duan, L.; Liu, H.; Lu, J.; Huo, Y. Experimental and numerical study on multi-impact performance of pre-damaged beams strengthened with CFRP. Eng. Struct. 2023, 285, 116034. [Google Scholar] [CrossRef]
  14. Guo, R.; Li, C.; Xian, G. Water absorption and long-term thermal and mechanical properties of carbon/glass hybrid rod for bridge cable. Eng. Struct. 2023, 274, 115176. [Google Scholar] [CrossRef]
  15. Huang, Y.; Lee, M.; Kan, Y.; Wang, W.; Wang, Y.; Pan, W.-B. Reinforced concrete beams retrofitted with UHPC or CFRP. Case Stud. Constr. Mater. 2022, 17, e01507. [Google Scholar] [CrossRef]
  16. Nguyen, D.L.; Ryu, G.S.; Koh, K.T.; Kim, D.J. Size and geometry dependent tensile behaviour of ultra-high-performance fiber-reinforced concrete. Compos. Part B-Eng. 2014, 58, 279–292. [Google Scholar] [CrossRef]
  17. Wang, W.; Huang, Y.; Lee, M.; Wang, Y.; Kan, Y.; Hsiao, Y.; Chang, H. Case study for ditch cover with ultra-high-performance concrete. Case Stud. Constr. Mater. 2022, 17, e01647. [Google Scholar] [CrossRef]
  18. Lee, M.; Wang, W.; Wang, Y.; Hsieh, Y.; Lin, Y. Mechanical Properties of High-Strength Pervious Concrete with Steel Fiber or Glass Fiber. Buildings 2022, 12, 620. [Google Scholar] [CrossRef]
  19. Kazemi, S.; Lubell, A. Influence of specimen size and fiber content on mechanical properties of ultra-high-performance fiber-reinforced concrete. ACI Mater. J. 2012, 109, 675–684. [Google Scholar]
  20. Elsayed, M.; Tayeh, B.A.; Elmaaty, M.A.; Aldahshoory, Y. Behaviour of RC columns strengthened with Ultra-High Performance Fiber Reinforced concrete (UHPFRC) under eccentric loading. J. Build. Eng. 2022, 47, 103857. [Google Scholar] [CrossRef]
  21. Ren, G.; Wu, H.; Fang, Q.; Liu, J. Effects of steel fiber content and type on static mechanical properties of UHPCC. Constr. Build. Mater. 2018, 163, 826–839. [Google Scholar] [CrossRef]
  22. Akeed, M.H.; Qaidi, S.; Faraj, R.H.; Mohammed, A.S.; Emad, W.; Tayeh, B.A.; Azevedo, A.R. Ultra-high-performance fiber-reinforced concrete. Part I: Developments, principles, raw materials. Case Stud. Constr. Mater. 2022, 17, e01290. [Google Scholar] [CrossRef]
  23. Li, P.; Yu, Q.; Brouwers, H. Effect of coarse basalt aggregates on the properties of Ultra-high Performance Concrete (UHPC). Constr. Build. Mater. 2018, 170, 649–659. [Google Scholar] [CrossRef]
  24. Huang, Y.; Grünewald, S.; Schlangen, E.; Luković, M. Strengthening of concrete structures with ultra high performance fiber reinforced concrete (UHPFRC): A critical review. Constr. Build. Mater. 2022, 336, 127398. [Google Scholar] [CrossRef]
  25. Zhang, J.; Li, H.; Liu, S.; Zhang, X.; Yang, C.; Zhang, R. Bond behavior of the CFRP-concrete interface under combined sustained load and sulfate erosion. Structures 2022, 35, 551–564. [Google Scholar] [CrossRef]
  26. Bakalarz, M.M.; Kossakowski, P.G. Application of Transformed Cross-Section Method for Analytical Analysis of Laminated Veneer Lumber Beams Strengthened with Composite Materials. Fibers 2023, 11, 24. [Google Scholar] [CrossRef]
  27. Xiang, K.; Wang, G. Calculation of Flexural Strengthening of Fire-damaged Reinforced Concrete Beams with CFRP Sheets. Procedia Eng. 2013, 52, 446–452. [Google Scholar] [CrossRef]
  28. ACI Committee 440. ACI PRC 440.2-17: Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures; American Concrete Institute: Farmington Hills, MI, USA, 2002. [Google Scholar]
  29. Ross, C.A.; Jerome, D.M.; Tedesco, J.W.; Hughes, M.L. Strengthening of reinforced concrete beams with externally bonded composite laminates. ACI Struct. 1999, 96, 212–220. [Google Scholar]
Figure 1. Test flowchart of beam retrofitted with RPC and CFRP.
Figure 1. Test flowchart of beam retrofitted with RPC and CFRP.
Buildings 13 01890 g001
Figure 2. Reinforced concrete sample retrofitted with RPC or CFRP.
Figure 2. Reinforced concrete sample retrofitted with RPC or CFRP.
Buildings 13 01890 g002
Figure 3. Flexural strength of RPC concretes.
Figure 3. Flexural strength of RPC concretes.
Buildings 13 01890 g003
Figure 4. Failure of CFRP-strengthened beam specimen.
Figure 4. Failure of CFRP-strengthened beam specimen.
Buildings 13 01890 g004
Figure 5. Failure of RPC-strengthened beam specimen.
Figure 5. Failure of RPC-strengthened beam specimen.
Buildings 13 01890 g005
Figure 6. Shear force diagram and bending moment diagram of a simple beam.
Figure 6. Shear force diagram and bending moment diagram of a simple beam.
Buildings 13 01890 g006
Figure 7. RPC convert section method.
Figure 7. RPC convert section method.
Buildings 13 01890 g007
Figure 8. CFRP convert section method.
Figure 8. CFRP convert section method.
Buildings 13 01890 g008
Figure 9. CFRP ultimate stress method.
Figure 9. CFRP ultimate stress method.
Buildings 13 01890 g009
Table 1. Chemical composition and properties of cement and silica fume.
Table 1. Chemical composition and properties of cement and silica fume.
Chemical Composition and PropertiesCement ICement IISilica Fume
SiO220.119.390
Fe2O32.42.31
Al2O35.44.31
CaO6261.10.4
MgO2.62.41
SO35.03.02
L.O.I2.30.93
Specific surface area (m2/g)0.370.3720
Specific gravity3.153.152.2
Table 2. Mix design of PC and RPC (kg/m3).
Table 2. Mix design of PC and RPC (kg/m3).
MixCementCoarse Aggregate Fine AggregateSilica FumeQuartz PowderSteel FiberSuperplasticizerWater
PC342 (1)9267850000222
RPC1720 (2)09002162524071.3133.7
RPC2720 (2)08602162528071.3133.7
Note: (1) Portland Type I Cement, (2) Portland Type II cement.
Table 3. Mechanical properties of CFRP sheet and epoxy resin.
Table 3. Mechanical properties of CFRP sheet and epoxy resin.
Materials PropertiesEpoxyCFRP
Areal weight (g/m2)-200
Thickness (mm/ply)-0.11
Ultimate tensile strain (%)-1.7
ConsistencyNon-sag-
Viscosity (25 °C)4725 mPa·s-
Compressive strength94 MPa-
Elasticity modulus2258 MPa23,456 MPa
Tensile strength42 MPa470 MPa
Table 4. Flexural strength of concrete beam reinforced with RPC and CFRP at 28 days age.
Table 4. Flexural strength of concrete beam reinforced with RPC and CFRP at 28 days age.
Reinforcement Type and Sample Number#1#2Mean (Coefficient of Variation)
(MPa)
PC control group4.825.675.24 (11.5%)
RPC1-reinforced 1 cm7.557.067.31 (4.7%)
RPC1-reinforced 2 cm9.5910.399.99 (5.7%)
RPC2-reinforced 1 cm8.489.188.83 (5.6%)
RPC2-reinforced 2 cm11.1213.1012.11 (11.5%)
CFRP-reinforced 1 layer8.998.568.78 (3.4%)
CFRP-reinforced 2 layers11.6711.2411.45 (2.6%)
CFRP-reinforced 3 layers14.0013.3213.66 (3.5%)
Table 5. Increase the ratio of theoretical calculation and experiment of maximum bending strength of reinforced PC beams.
Table 5. Increase the ratio of theoretical calculation and experiment of maximum bending strength of reinforced PC beams.
Reinforcement TypeExperimental ValueTheoretical Calculation Value
Conversion Section MethodUltimate Stress Method
RPC1 reinforced 1 cm39.5%34.9%-
RPC1 reinforced 2 cm90.7%92.7%-
RPC2 reinforced 1 cm68.5%70.4%-
RPC2 reinforced 2 cm131.2%140.6%-
CFRP1 reinforced 1 layer67.3%2.8%104.9%
CFRP2 reinforced 2 layers118.4%6.4%310.8%
CFRP3 reinforced 3 layers160.8%10.3%618.2%
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Lee, M.-G.; Huang, Y.-S.; Kan, Y.-C.; Wang, W.-C.; Wang, Y.-C.; Wu, C.-H. Flexure Strengthening and Analysis Using CFRP Composite and Reactive Powder Concrete. Buildings 2023, 13, 1890. https://doi.org/10.3390/buildings13081890

AMA Style

Lee M-G, Huang Y-S, Kan Y-C, Wang W-C, Wang Y-C, Wu C-H. Flexure Strengthening and Analysis Using CFRP Composite and Reactive Powder Concrete. Buildings. 2023; 13(8):1890. https://doi.org/10.3390/buildings13081890

Chicago/Turabian Style

Lee, Ming-Gin, Yi-Shuo Huang, Yu-Cheng Kan, Wei-Chien Wang, Yung-Chih Wang, and Chien-Hsing Wu. 2023. "Flexure Strengthening and Analysis Using CFRP Composite and Reactive Powder Concrete" Buildings 13, no. 8: 1890. https://doi.org/10.3390/buildings13081890

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop