Communication

Contact Fatigue Behavior Evolution of 18CrNiMo7-6 Gear Steel Based on Surface Integrity

1
Zhengzhou Research Institute of Mechanical Engineering Co., Ltd., Zhengzhou 450052, China
2
School of Mechanical Engineering, Tongji University, Shanghai 200092, China
3
School of Aerospace Engineering, Zhengzhou University of Aeronautics, Zhengzhou 450046, China
4
ICMMO/SP2M, UMR CNRS 8182, Paris-Saclay University, 91405 Paris, France
*
Author to whom correspondence should be addressed.
Metals 2023, 13(9), 1605; https://doi.org/10.3390/met13091605
Submission received: 14 August 2023 / Revised: 13 September 2023 / Accepted: 14 September 2023 / Published: 17 September 2023
(This article belongs to the Special Issue Feature Papers in Metal Failure Analysis)

Abstract

:
In this work, the surface integrity (surface morphology, microstructure, microhardness, residual stress) of contact fatigue (CF) samples with different numbers of running cycles was comprehensively studied. Based on typical working conditions, a fatigue life evaluation method was proposed based on the evolution law of surface integrity. The CF with different numbers of running cycles revealed that the average grain size decreased with the increase in the number of running cycles, and the surface microhardness, residual stress and surface roughness Ra increased first and then decreased. In addition, the relationships between different surface integrity parameters and fatigue life were plotted. Moreover, based on the fatigue life profiles, the running state and remaining life of gear samples can be evaluated.

1. Introduction

Gears are the most widely used form in transmission systems. Compared with other mechanical transmission forms, gear transmission can change speed, torque and direction, which also has the advantages of high transmission efficiency, accuracy, a stable transmission ratio, and a large power range [1,2,3]. Due to the high working speed and large load, the gear needs to withstand the shear stress and impact force under the action of circulation. However, gear fatigue is an inevitable phenomenon in the service life. Gear fatigue can eventually lead to serious failures, including surface pitting, spalling and fracture [4,5]. These failures can significantly reduce the remaining service life, and even affect the normal operation of the mechanical equipment. For example, Bejger et al. argued that gears are subjected to alternating loads due to wind speed changes and free braking pulses, which makes them one of the most fragile components of a wind turbine with low reliability, and gear fatigue failure led to the abnormal operation of wind power generation devices [6].
The gear service life is directly related to the performance characteristics of the tooth surface [7,8]. Obtaining the surface integrity characteristics of the gear surface is an important step to improve service life. In order to effectively monitor the degradation of gear material performance during the service cycle, Feng et al. proposed gear remaining service life and fatigue propagation monitoring technology based on vibration [9]. Xiang et al. developed a new type of long short-term memory neural network with weight amplification to predict gear remaining life, which was based on fusing the time-domain and frequency-domain features of vibration signals [10]. Wang et al. used the Archard model to formulate the gear tooth wear and predicted gear service life based on tooth surface wear [11]. Moreover, a variety of surface strengthening techniques have also been applied to gears to improve their fatigue life, such as laser shock peening, surface ultrasonic rolling, pneumatic shot peening, etc. [12,13,14]. Zhang et al. [15] found that surface ultrasonic rolling can improve the surface integrity and fatigue life of the 17Cr2Ni2MoVNb gear steel due to the surface work hardening layer. Qu et al. [16] revealed that shot peening can improve the fatigue life of shaft steel due to the formation of dislocation tangles. In addition, some studies have proposed crack initiation and fatigue life prediction based on surface damage and wear performance [17,18].
Although a series of research achievements have been made in improving the surface integrity, fatigue life and service performance of gear samples, the variation law of tooth surface integrity during the service period has not yet been established. Therefore, the aim of this work is to analyze the variation in surface integrity with different numbers of running cycles, which meant testing sample surfaces at different cycle counts. The results provide basic data for providing tooth surface characteristic parameters and later gear maintenance.

2. Materials and Methods

The chemical components (wt.%) of 18CrNiMo7-6 steel were C 0.18, Si 0.28, Mn 0.7, Cr 1.6, Ni 1.48, Al 0.097, Mo 0.29 and Fe balance. The heat treatment process was as follows: the carburizing temperature was 920~930 °C for 45 h. After carburizing treatment, the samples were furnace-cooled to 850 °C for 0.5 h and quickly quenched in oil for 0.5 h, and the samples were tempered at 160 °C for 3 h.
CF tests were performed on a roller fatigue tester, and vibration signals were used to monitor contact surface damage. The fatigue sample size and a physical image of the roller fatigue tester are shown in Figure 1. Mobil lubricant (APIGL 80W90) was selected for lubrication, and CF samples of 18CrNiMo7-6 steel were processed according to standard YB/T5345-2014 [19]. A scanning electron microscope (SEM, NOVA NANOSEM 430, Financial Education Initiative, Hillsboro, OR, USA) was used to observe the surface morphology. Electrolytic polishing was used to prepare the target surface for electron backscattering diffraction (EBSD) characterization. The EBSD characterization was carried out on HKL Symmetry equipment (Oxford Instruments, Abingdon, UK), with a 20 kV accelerating voltage and scanning step size of 0.07 µm. A durometer (SCTMC, HV-50, Shangcai Instruments, Shanghai, China) was used to evaluate microhardness, and the applied load and dwelling time were 200 g and 15 s, respectively. The residual stresses were measured by using a X-ray diffraction residual stress tester (Proto LXRD, Michigan, ON, Canada) with the sin2ψ method and Cr-Kα radiation. A roughness tester was used to evaluate surface roughness (Mahr-300C, Mahr Group, Limbach-Oberfrohna, Germany).
The Hertzian stress between the driven roller and driving roller was calculated using the following equation:
P 0 = 1 π 6 F × ( 1 R 1 + 1 R 2 1 v 1 2 E 1 + 1 v 2 2 E 2 ) 2 3
where σ is the contact stress; F is the loading force; R 1 is the radius of driven roller, R 2 is the radius of the driving roller, E 1 and E 2 are the elastic modulus of the samples, respectively, and V 1 and V 2 are the Poisson’s ratios of samples.
When the vertical load is 13,000 N, the corresponding Hertzian stress was 6 GPa.

3. Results

3.1. Determining Fatigue Life

CF tests of different running periods were carried out to obtain the surface integrity parameters of the 18CrNiMo7-6 steel samples at different stages. The premise of dividing the fatigue life of the sample reasonably was based on obtaining the fatigue life distribution curve. Six groups of fatigue tests were carried out to obtain the mean life of the samples. The details of the experimental results of fatigue life are shown in Table 1. The fatigue life distribution curve of the 18CrNiMo7-6 steel samples is shown in Figure 2.
As can be seen from Table 1 and Figure 2, the mean life of the 18CrNiMo7-6 steel samples was 3.80 × 107 cycles, and most samples have fatigue failure of more than 107 cycles in the tests. Therefore, the study on the evolution law of the surface integrity of the samples before fatigue failure was of great significance for revealing the fatigue failure mechanisms and improving the fatigue life. Based on the fatigue life obtained, the tested samples were divided into different numbers of running cycles, namely the initial state, 0 cycles (Sample 1), 3 × 106 cycles (Sample 2), 5 × 106 cycles (Sample 3), 8 × 106 cycles (Sample 4) and 3.8 × 107 cycles (Sample 5), to study the surface integrity evolution characteristics.

3.2. Microstructure

Figure 3 presents the cross-sectional EBSD microstructure, average grain size and pole figures near the fatigue failure location after different numbers of running cycles. As shown in Figure 3(a1), in the sample with coarse grains in the initial state, the grain size was distributed in the range of 0~25 μm, and 74.79% of the grains were smaller than 5 μm. The average grain size was 0.94 μm, as presented in Figure 3(a2). In addition, it can be observed that the layered structures were distributed along the vertical loading direction. Figure 3(a3) presents the (001), (011) and (111) pole figures with a maximum intensity value close to 7.17. After operation, the original coarse grains were slightly refined, as shown in Figure 3(a1–e1), and grain size was decreased after contact operation. As shown in Figure 3(a2–e2), the average grain size of the samples with 3 × 106, 5 × 106, 8 × 106 and 3.8 × 107 cycles was 0.82 μm, 0.78 μm, 0.70 μm and 0.67 μm, respectively. It should be noted that the polar density of the samples decreased, suggesting that the texture orientation of the material properties in the initial state was changed, as shown in Figure 3(a3–e3). Wang et al. [20] discovered the deformation characteristics and texture evolution mechanisms of martensite steel, and they found that the low-angle grain boundaries with misorientation angles help to improve fatigue performance. In addition, the average grain size of the samples decreased with an increase in the number of running cycles. At the same time, it could be seen that the proportion of small grain sizes had increased. Also, it can be inferred that with the increase in the number of running cycles, the contact surface morphology of the samples changed, causing different vibration between contact surfaces, resulting in the differentiation of grain size and polar density. Moreover, the vibration effects can deform the surface layer material and significantly accelerate grain refinement. Based on the Hall–Petch relationship [21], the relationship between grain size and sample strength can be obtained, which also would help improve the fatigue behavior. Based on the above conclusion, it can be determined that the running state of the fatigue samples directly affects the characteristic change in the microstructure of the material surface layer, which has important guiding significance for evaluating the service performance of the fatigue samples by using this evolutionary characteristic.

3.3. Microhardness and Residual Stress

Figure 4a shows the surface microhardness of the samples with different numbers of running cycles. The initial microhardness of the sample was 696 HV0.2, and the microhardness of the samples with 3 × 106, 5 × 106, 8 × 106 and 3.8 × 107 cycles was 712 HV0.2, 720 HV0.2, 708 HV0.2 and 688 HV0.2, respectively. It can be seen that with the increase in the number of running cycles, the surface microhardness of samples increased first and then decreased. The main reasons for the increase in surface microhardness was work hardening, but with the increase in the number of running cycles, the temperature of the contact interface has a softening effect. Cvetkovski et al. [22] studied the thermal softening of fine pearlitic steel and its influence on fatigue properties, and their research conclusions proved that material softening can lead to a decrease in material deformation resistance, resulting in a decrease in fatigue life. Figure 4b shows residual stress at the top surface of the samples with different numbers of running cycles. The surface residual stress in the initial state of the sample was compressed, which was −24 MPa, and the residual stress of the samples with 3 × 106, 5 × 106, 8 × 106 and 3.8 × 107 cycles was −185 MPa, −277 MPa, −307 MPa and −270 MPa, respectively. The surface residual stress of the samples with different numbers of running cycles was higher than that in the initial state. It should be noted that the residual stress value of Sample 5 was lower than that of Sample 4 and Sample 3, which may be due to the softening effect of the contact surface accelerating the decline in residual stress and material strength with the increase in the number of cycles [23]. This inference was consistent with the conclusion of microhardness analysis.

3.4. Surface Roughness and Morphology

Figure 5a presents the surface roughness of the samples with different numbers of running cycles, and it can be found that the the surface roughness Ra value has great differences after different numbers of running cycles. The surface roughness Ra value increased first and then decreased with the increase in the number of fatigue cycles. The initial surface roughness value Ra of the Sample 1 was 0.491 μm. The surface roughness of Sample 2, Sample 3, Sample 4 and Sample 5 cycles was 0.206, 0.255, 1.688 and 2.099 μm, respectively. In addition, the surface roughness curve of Sample 1 shows more peaks and troughs, and has high curve fluctuations. With the contact operation of the fatigue samples, the peaks were gradually flattened, and the roughness curves were relatively smooth. Figure 5b presents the surface morphology of the samples with different numbers of running cycles. The machining marks produced in the process of sample preparation were regularly distributed on the sample surface, and this was the reason for the large fluctuation in the surface roughness curve of the original sample. With the increase in the number of running cycles, the machining marks on the surface gradually disappeared, and new surface damage can be observed in Figure 6b,c. Also, local smooth areas were formed, and surface damage started from slight scratches and gradually evolved into pitting until the final spalling. This was because the machining marks were smoothed out as the number of running cycles increased, while surface damage was formed, resulting in an increase in roughness value. Zhang et al. [24] demonstrated that the surface morphology characteristics are important factors affecting CF performance. It should be noted that the pitting and spalling on the surface of Sample 5 would further expand into delamination failure, resulting in extensive material peeling. According to EDS analysis of the composition distribution of spalling in Figure 6e, no oxygen element was detected, indicating that there was no obvious oxidative wear and fatigue damage on the contact surface before 18CrNiMo7-6 steel severe fatigue failure. Related studies suggested that oxidation is one of the important factors affecting fatigue life [11,25].

3.5. Analysis of the Relationship between Surface Integrity and Fatigue Life

Figure 7 displays the fatigue life evolution relationships between surface roughness, microhardness, average grain size and residual stress. Both surface roughness and microhardness can be obtained using portable equipment, and thus the service performance of the samples can be inferred. The average grain size obtained via EBSD was relatively complex, which was a supplement to the evaluation and fatigue life evolution method. Figure 7a displays the relationships between surface roughness, microhardness and fatigue life. It can be seen that the fatigue life of samples can be clearly evaluated under the coupling relationships of microhardness and surface roughness. In addition, compared with surface roughness, the influence of microhardness on CF life was relatively weak, and when the surface roughness increased from 0.4 μm to 2.0 μm, it gradually approached the fatigue failure point. Moreover, when the surface roughness was greater than 1.6 μm, the influence of microhardness on fatigue life decreased markedly. Figure 7b displays the relationships between average grain size, residual stress and fatigue life. It can be seen that the average grain size was between 0.7 μm and 0.8 μm, and the samples were in a healthy running state. With the accumulation of surface damage, samples produced more severe vibration, and formed an impact effect, which resulted in the further reduction in surface grain size and a greater release of residual stress [26]. Therefore, samples were also close to the fatigue failure point.

4. Discussion

By obtaining the surface integrity parameters of 18CrNiMo7-6 gear steel samples with different numbers of running cycles, the variation rules of surface integrity can be identified, providing the most basic data for the prediction of the fatigue life of samples and the maintenance of a healthy running state. There have been few reports on the use of this method to predict fatigue life and to monitor the operational health status of gears. Once the method is successfully applied, it will provide a new solution for the health monitoring of the core moving components of high-end equipment such as gears and bearings. Future work will further study the effect of different heat treatment processes and running conditions on the surface integrity of 18CrNiMo7-6 gear steel and improve the basic data of the fatigue properties of gear materials.

5. Conclusions

In this paper, the surface integrity (surface morphology, microstructure, microhardness, residual stress) characteristics of CF samples based on different numbers of running cycles was investigated. Also, the relationship between surface integrity and fatigue life was analyzed. The main findings are as follows:
(1)
A large difference in the surface integrity characteristics of different numbers of running cycles was observed. Surface machining marks were first gradually polished (about 5 × 106 cycles) and then surface pitting damage was formed (about 8 × 106 cycles) during the fatigue test.
(2)
The average grain size decreased with the increase in the number of running cycles. Within the testing range, the grain size gradually decreased by 0.94 μm from 0.67 μm.
(3)
As the number of running cycles increased, the surface microhardness, residual stress and surface roughness Ra increased first and then decreased.
(4)
Based on the evolution law of surface integrity mentioned above, the relationships between different surface integrity parameters and fatigue life were plotted. When the surface roughness Ra increased from 0.4 μm to 2.0 μm, it gradually approached the failure point, and the average grain size was between 0.7 μm and 0.8 μm, meaning that the samples were in a healthy running state.

Author Contributions

Conceptualization, L.W. and Y.Z.; methodology, Y.L.; data curation, L.W.; writing—original draft preparation, Y.Z.; writing—review and editing, V.J. and A.L.; project administration, L.W.; funding acquisition, Y.Z. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the China Postdoctoral Science Foundation (2022M712920), Youth Research Funds Plan of Zhengzhou University of Aeronautics (23HQN01001), Key Scientific Research Project of Colleges and Universities in Henan Province (23A460018) and Henan Province Science and Technology Research Project (232102221021).

Data Availability Statement

Data will be made available upon request.

Acknowledgments

The authors would like to thank ZKKF (Beijing) Science and Technology Company for supporting the evaluation of microstructure.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Sevan, G.; Monzer, D.; Francisco, C. Data-driven inverse problem for optimizing the induction hardening process of C45 spur-gear. Metals 2023, 13, 997. [Google Scholar]
  2. Xu, C.L.; Dai, S.L.; Wang, X.; Zhang, B.; Luo, X.K.; Tang, Z.H. Effect of the pre-shot peening and nitrogen ion implantation combined surface treatments on the surface structure and properties of gear steel 16Cr3NiWMoVNbE. Metals 2022, 12, 1509. [Google Scholar] [CrossRef]
  3. Zhang, Y.L.; Wang, J.K.; Wu, L.J.; Wang, Z.; Liu, L.; Ji, V. Surface integrity and bending fatigue behavior of aeronautic gear steel under combined carburized treatment and shot peening. Int. J. Fatigue 2023, 169, 107488. [Google Scholar] [CrossRef]
  4. Mahendra, S.R.; Shivdayal, P. Crack propagation and fatigue life estimation of spur gear with and without spalling failure. Theor. Appl. Fract. Mech. 2023, 127, 104020. [Google Scholar]
  5. Xu, C.L.; Wang, X.; Geng, Y.X.; Wang, Y.M.; Sun, Z.W.; Yu, B.; Tang, Z.H.; Dai, S.L. Effect of shot peening on the surface integrity and fatigue property of gear steel 16Cr3NiWMoVNbE at room temperature. Int. J. Fatigue 2023, 172, 107668. [Google Scholar] [CrossRef]
  6. Bejger, A.; Ewelina, F.; Przemysław, B. Failure analysis of wind turbine planetary gear. Energies 2021, 14, 6768. [Google Scholar] [CrossRef]
  7. Vivek, D.; Vaseem, M.; Praveen, P. Investigation and optimization of hypoid gear micro-geometry parameters and axle deflections to improve the contact stress distribution and fatigue life of hypoid gears. Mater. Today 2023, 72, 1950–1956. [Google Scholar]
  8. Liu, W.M.; Xu, Z.Q.; Liu, H.M.; Liu, X.D. Cause analysis and solution of premature fracture of suspension rod in metro gear box. Metals 2022, 12, 1426. [Google Scholar] [CrossRef]
  9. Feng, K.; Ji, J.C.; Ni, Q. A novel gear fatigue monitoring indicator and its application to remaining useful life prediction for spur gear in intelligent manufacturing systems. Int. J. Fatigue 2023, 169, 107459. [Google Scholar] [CrossRef]
  10. Xiang, S.; Qin, Y.; Zhu, C.C.; Wang, Y.Y.; Chen, H.Z. Long short-term memory neural network with weight amplification and its application into gear remaining useful life prediction. Eng. Appl. Artif. Intell. 2020, 91, 103587. [Google Scholar] [CrossRef]
  11. Wang, H.B.; Tang, L.W.; Zhou, C.J.; Shi, Z.Y. Wear life prediction method of crowned double helical gear drive in point contact mixed elastohydrodynamic lubrication. Wear 2021, 484, 204041. [Google Scholar] [CrossRef]
  12. Pushpendra, K.D.; Vinjamuri, R.; Arun, K.R.; Ranganathan, K.; Bindr, K.S.; Krishna, D. Effect of laser shock peening on ratcheting strain accumulation, fatigue life and bulk texture evolution in HSLA steel. Int. J. Fatigue 2022, 163, 107033. [Google Scholar]
  13. Zhao, W.D.; Liu, D.X.; Zhang, X.H.; Zhou, Y.; Zhang, R.X.; Zhang, H.; Ye, C. Improving the fretting and corrosion fatigue performance of 300M ultra-high strength steel using the ultrasonic surface rolling process. Int. J. Fatigue 2019, 121, 30–38. [Google Scholar] [CrossRef]
  14. Zhang, Y.L.; Lai, F.Q.; Qu, S.G.; Ji, V.; Liu, H.P.; Li, X.Q. Effect of shot peening on residual stress distribution and tribological behaviors of 17Cr2Ni2MoVNb steel. Surf. Coat. Technol. 2020, 386, 125497. [Google Scholar] [CrossRef]
  15. Zhang, Y.L.; Wu, L.J.; Shi, D.P.; Wang, Z.; Jin, H.; Liu, L.; Qu, S.G.; Ji, V. Surface integrity and tribological behavior of 17Cr2Ni2MoVNb steel under combined carburizing treatment and ultrasonic rolling. Surf. Coat. Technol. 2023, 461, 129371. [Google Scholar] [CrossRef]
  16. Qu, S.G.; Duan, C.F.; Hu, X.F.; Jia, S.Y.; Li, X.Q. Effect of shot peening on microstructure and contact fatigue crack growth mechanism of shaft steel. Mater. Chem. Phys. 2021, 274, 125116. [Google Scholar] [CrossRef]
  17. Ling, F.F.; Bryant, M.D.; Doelling, K.L. On irreversible thermodynamics for wear prediction. Wear 2002, 253, 1165–1172. [Google Scholar] [CrossRef]
  18. Beheshti, A.; Khonsari, M.M. On the prediction of fatigue crack initiation in rolling/sliding contacts with provision for loading sequence effect. Tribol. Int. 2011, 44, 1620–1628. [Google Scholar] [CrossRef]
  19. Li, J.W.; Zhao, X.H.; Li, Y.J.; Wu, J.Z. Effect of service condition and shot peening on rolling contact fatigue performance of aviation gear steel. Surf. Technol. 2023, 52, 14–24. (In Chinese) [Google Scholar]
  20. Wang, X.; Xu, Y.B.; Gao, Y.J.; Wang, Y.; Misra, E. strength-ductility combination in a novel Cu–Ni bearing Q&P steel by tailoring the characteristics of fresh martensite. J. Mater. Res. Technol. 2023, 24, 9015–9029. [Google Scholar]
  21. Seok, J.P.; Kyung, S.K.; Jee, H.K.; Sung, J.K. Effects of carbon and nitrogen on Hall–Petch relationship in austenitic stainless steel. J. Mater. Res. Technol. 2022, 19, 2960–2964. [Google Scholar]
  22. Cvetkovski, K.; Ahlstrom, J.; Karlsson, B. Thermal softening of fine pearlitic steel and its effect on the fatigue behaviour. Procedia Eng. 2010, 2, 541–545. [Google Scholar] [CrossRef]
  23. Shrikant, T.; Mudigonda, S. The effect of residual stresses, grain size, grain orientation and hardness on the surface quality of Co–Cr L605 alloy in photochemical machining. J. Alloys Compd. 2019, 804, 84–92. [Google Scholar]
  24. Zhang, Y.L.; Qu, S.G.; Lu, F.; Lai, F.Q.; Ji, V.; Liu, H.P.; Li, X.Q. Microstructures and rolling contact fatigue behaviors of 17Cr2Ni2MoVNb steel under combined ultrasonic surface rolling and shot peening. Int. J. Fatigue 2020, 141, 105867. [Google Scholar] [CrossRef]
  25. Zhang, Y.L.; Lai, F.Q.; Qu, S.G.; Liu, H.P. Effect of ultrasonic surface rolling on microstructure and rolling contact fatigue behavior of 17Cr2Ni2MoVNb steel. Surf. Coat. Technol. 2019, 366, 321–330. [Google Scholar] [CrossRef]
  26. Zhao, L.Q.; Hu, H.X.; Gao, X.M. Effect of toughness and ductility on the cavitation erosion of martensitic stainless steel. Metals 2023, 13, 154. [Google Scholar] [CrossRef]
Figure 1. Fatigue sample size and testing machine.
Figure 1. Fatigue sample size and testing machine.
Metals 13 01605 g001
Figure 2. Fatigue life distribution curve of the 18CrNiMo7-6 steel.
Figure 2. Fatigue life distribution curve of the 18CrNiMo7-6 steel.
Metals 13 01605 g002
Figure 3. EBSD microstructure, average grain size and pole figures of the samples with different numbers of running cycles: (a1a3) Sample 1; (b1b3) Sample 2; (c1c3) Sample 3; (d1d3) Sample 4; (e1e3) Sample 5.
Figure 3. EBSD microstructure, average grain size and pole figures of the samples with different numbers of running cycles: (a1a3) Sample 1; (b1b3) Sample 2; (c1c3) Sample 3; (d1d3) Sample 4; (e1e3) Sample 5.
Metals 13 01605 g003aMetals 13 01605 g003b
Figure 4. (a) Surface microhardness of the samples with different numbers of running cycles; (b) Surface residual stress of different samples with different numbers of running cycles.
Figure 4. (a) Surface microhardness of the samples with different numbers of running cycles; (b) Surface residual stress of different samples with different numbers of running cycles.
Metals 13 01605 g004
Figure 5. Surface roughness of the samples with different numbers of running cycles: (a) Sample 1; (b) Sample 2; (c) Sample 3; (d) Sample 4; (e) Sample 5; (f) surface roughness summary map.
Figure 5. Surface roughness of the samples with different numbers of running cycles: (a) Sample 1; (b) Sample 2; (c) Sample 3; (d) Sample 4; (e) Sample 5; (f) surface roughness summary map.
Metals 13 01605 g005
Figure 6. Surface morphology and roughness of the samples with different numbers of running cycles: (a) Sample 1; (b) Sample 2; (c) Sample 3; (d) Sample 4; (e) Sample 5; (f) EDS analysis of the Sample 5.
Figure 6. Surface morphology and roughness of the samples with different numbers of running cycles: (a) Sample 1; (b) Sample 2; (c) Sample 3; (d) Sample 4; (e) Sample 5; (f) EDS analysis of the Sample 5.
Metals 13 01605 g006aMetals 13 01605 g006b
Figure 7. The relationships between surface integrity parameters and fatigue limit. (a) the relationships be-tween surface roughness, microhardness and fatigue life. (b) the relationships between average grain size, residual stress and fatigue life.
Figure 7. The relationships between surface integrity parameters and fatigue limit. (a) the relationships be-tween surface roughness, microhardness and fatigue life. (b) the relationships between average grain size, residual stress and fatigue life.
Metals 13 01605 g007
Table 1. Fatigue life distribution of 18CrNiMo7-6 steel samples.
Table 1. Fatigue life distribution of 18CrNiMo7-6 steel samples.
SampleNO.1NO.2NO.3NO.4NO.5NO.6Mean Life
Fatigue life8.23 × 1069.35 × 1061.35 × 1072.55 × 1074.77 × 1075.04 × 1073.80 × 107
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Wu, L.; Lv, Y.; Zhang, Y.; Li, A.; Ji, V. Contact Fatigue Behavior Evolution of 18CrNiMo7-6 Gear Steel Based on Surface Integrity. Metals 2023, 13, 1605. https://doi.org/10.3390/met13091605

AMA Style

Wu L, Lv Y, Zhang Y, Li A, Ji V. Contact Fatigue Behavior Evolution of 18CrNiMo7-6 Gear Steel Based on Surface Integrity. Metals. 2023; 13(9):1605. https://doi.org/10.3390/met13091605

Chicago/Turabian Style

Wu, Luji, Yongxin Lv, Yalong Zhang, Anhu Li, and Vincent Ji. 2023. "Contact Fatigue Behavior Evolution of 18CrNiMo7-6 Gear Steel Based on Surface Integrity" Metals 13, no. 9: 1605. https://doi.org/10.3390/met13091605

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop