Next Article in Journal
Patient-Level Exposure to Actionable Pharmacogenomic Medications in a Nationally Representative Insurance Claims Database
Previous Article in Journal
The Impact of Chronic Kidney Disease on the Mortality Rates of Patients with Urological Cancers—An Analysis of a Uro-Oncology Database from Eastern Europe
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

48-Month Clinical Outcomes and Prognostic Factors in an All-Comers Population with Acute Coronary Syndrome and Chronic Coronary Syndrome Undergoing Percutaneous Coronary Intervention with a Sirolimus-Eluting Stent

1
Department of Invasive Cardiology, Centre of Postgraduate Medical Education, 02-507 Warsaw, Poland
2
Department of Cardiology and Internal Medicine, School of Medicine, Collegium Medicum, University of Warmia and Mazury, 10-082 Olsztyn, Poland
3
Department of Cardiology, Provincial Integrated Hospital, 09-400 Plock, Poland
4
Department of Cardiology, State Medical Institute of the Ministry of Interior and Administration, 02-507 Warsaw, Poland
*
Author to whom correspondence should be addressed.
J. Pers. Med. 2023, 13(11), 1573; https://doi.org/10.3390/jpm13111573
Submission received: 20 September 2023 / Revised: 27 October 2023 / Accepted: 1 November 2023 / Published: 3 November 2023
(This article belongs to the Section Mechanisms of Diseases)

Abstract

:
We characterized the performance as well as safety of a second-generation thin-strut sirolimus-eluting stent with a biodegradable polymer, Alex Plus (Balton, Poland), deployed in the acute coronary syndrome (ACS) setting. We enrolled patients who were subjected to percutaneous coronary intervention (PCI) between July 2015 and March 2016 and took into consideration demographics, clinical and laboratory data, and clinical outcomes. We defined the primary endpoint as the 48-month rate of major cardiovascular adverse events (MACE), including cardiac death, myocardial infarction (MI), or target lesion revascularization (TLR). The secondary endpoints were all-cause death, cardiac death, MI, and TLR rates at 12-, 24-, 36-, and 48 months. We enrolled 232 patients in whom 282 stents were implanted, including 88 ACS and 144 chronic coronary syndrome (CCS) patients. The mean age of the ACS population was 67 ± 13 years old, and 32% of it consisted of females. Patients with ACS were characterized by lower rates of arterial hypertension (85.2% vs. 95.8%, p = 0.004), dyslipidemia (67% vs. 81.9%, p = 0.01), prior MI (34.1% vs. 57.6%, p < 0.001), and prior PCI (35.2% vs. 68.8%, p < 0.001). At 48 months, among the ACS patients, the rates of MACE, death, cardiac death, MI, and TLR were 23.9%, 11.4%, 7.9%, 9.1%, and 10.2%, respectively. No stent thrombosis cases were reported. Multivariable Cox regression revealed that the statistically significant MACE predictors were massive calcifications in coronary arteries (HR 9.0, 95% CI 1.75–46.3, p = 0.009), post-dilatation (HR 3.78, 95% CI 1.28–11.2, p = 0.016), prior CABG (HR 6.64, 95% CI 1.62–27.1, p = 0.008), vitamin K antagonist use (HR 5.99, 95% CI 1.29–27.8, p = 0.022), and rivaroxaban use (HR 51.7, 95% CI 4.48–596, p = 0.002). The study findings show that Alex Plus was effective and safe in a contemporary cohort of real-world ACS patients undergoing primary PCI. The outcomes were comparable between the ACS and chronic coronary syndrome patients, with a trend of lower TLR in ACS patients at 4 years.

1. Introduction

The clinical spectrum of acute coronary syndromes (ACSs) comprises ST-segment elevation myocardial infarction (STEMI), non-ST-segment elevation myocardial infarction (NSTEMI), and unstable angina. These clinical scenarios are graduated, considering the disease severity and timing of their management [1]. Most ACS cases are provoked by an atherosclerotic plaque rupture accompanied by thrombus formation. Lipid-rich plaque ruptures are observed in two-thirds of ACS patients. Notably, a significant proportion of patients undergo ACS induced by plaque erosion, calcific nodules, coronary embolisms, coronary spasms, or spontaneous coronary artery dissection [2]. Many patients are high-risk patients, unstable, and often denied cardiac surgery; therefore, PCI is the only option for revascularization in this setting [3].
The incidence of STEMI has decreased in Western countries due to improved risk factor control. Nevertheless, in-hospital mortality and morbidity rates remain high [4]. Percutaneous coronary intervention (PCI) is the treatment method of choice for most ACS patients [5,6,7]. Widely used drug-eluting stents (DESs) are efficient in preventing restenosis and target lesion revascularization (TLR). However, still, there is an increased risk of neoatherosclerosis and very-late stent thrombosis, especially among ACS patients [7,8,9]. Additionally, the ruptured plaques of STEMI patients are characterized by a large necrotic core and abundant thrombi; therefore, they may be predisposed to vascular healing process impairment and an increased risk of in-stent thrombosis [10]. With advancements in DES technology made to overcome these obstacles, stents are now designed with improved alloys (cobalt–chromium or platinum–chromium), including thinner-stent struts (<80 μm), as well as enhanced polymer biocompatibility and new -limus drugs [11,12,13,14]. Stent polymers serve different aims. The polymer employed facilitates drug adhesion and release and biocompatibility and modulates thrombogenicity. Not all polymers are the same. The coating materials of stents can be divided into subgroups, such as organic or inorganic, biodegradable or durable, uniform or nonuniform drug delivery, and luminal or abluminal coating [15].
We characterized the performance and safety of PCI with a second-generation thin-strut sirolimus-eluting stent (SES) implanted in the ACS setting with a 4-year follow-up.

2. Materials and Methods

2.1. Study Design and Study Population

We collected data retrospectively, obtaining them from hospital records. We considered all consecutive patients who were subjected to PCI with sirolimus-eluting coronary stent Alex Plus (Balton, Poland) deployment between July 2015 and March 2016, as described previously [16]. We included patients with chronic coronary syndrome (CCS) as well as ACS, i.e., STEMI, NSTEMI, and unstable angina.
We took into consideration a range of baseline demographics, clinical and laboratory data, and clinical outcomes at a 48-month follow-up between CCS and ACS patients.

2.2. Alex plus Stent Characteristics

Alex Plus is a cobalt–chromium (L605) stent with 70 μm struts. The stent has an open-cell design with two connectors between segments. The stent releases sirolimus (1.3 μg/mm2) from a biodegradable polymer over the course of 8 weeks [17,18]. Alex Plus is available in the following range of parameters: diameter of 2.0–5.0 mm and length of 8.0–40.0 mm. The operator can safely overexpand the stent during post-dilatation (3.5 mm → 4.3 mm; 4.0 mm → 4.7 mm; 5.0 mm → 6.0 mm).

2.3. Data Collection

Hospital records allowed us to obtain data on the following comorbidities: arterial hypertension, diabetes, dyslipidemia, prior MI, prior PCI, chronic kidney disease (eGFR < 60 mL/min/1.73 m2), history of coronary artery bypass grafting (CABG), peripheral artery disease, prior stroke, smoking, and chronic obstructive pulmonary disease. Moreover, we analyzed procedure details, including lesion characteristics (A, B1, B2, and C according to AHA/ACC classification [19]) and periprocedural adverse events. Additionally, SYNTAX (https://syntaxscore.org accessed on 24–25 August 2023), SYNTAX II [20], and EuroScore II (https://www.euroscore.org accessed on 19–20 August 2023) parameters were calculated. We also analyzed laboratory results obtained upon admission: complete blood count with differentials (WBC—white blood cells, RBC—red blood cells, Hgb—hemoglobin, and PLT—platelets), glucose, glycated hemoglobin (HbA1c), troponin T, CK, CK-MB, lipid profiles, creatinine, and estimated glomerular filtration rate (eGFR). Finally, we provided a summary of medications prescribed upon discharge [14].
Echocardiographic data (left-ventricular ejection fraction (LVEF), left-ventricular end-diastolic diameter, posterior wall diameter, intraventricular septal diameter, tricuspid annular plane systolic excursion, and left-atrial diameter) were retrieved with a standard, commercially available diagnostic ultrasound system (iE 33, Philips Healthcare, Best, Netherlands). Measurements were obtained by experienced cardiologists and based on the European Association of Cardiovascular Imaging guidelines [21].

2.4. Study Endpoints

We defined the primary endpoint as the 48-month rate of major cardiovascular adverse events (MACE), including cardiac death, myocardial infarction (MI), and target lesion revascularization (TLR). The secondary endpoints were all-cause death, cardiac death, MI, and TLR rates at 12, 24, 36, and 48 months.

2.5. Statistical Methods

Descriptive statistics are shown as mean values with standard deviation; minimum values; median values with interquartile range; and maximum values for continuous variables, and categorical variables are presented as counts and percentages. Pearson’s Chi-squared test or Fisher’s exact test were used to compare categorical variables between 2 subgroups (CCS and ACS patients). We applied Fisher’s exact test if at least one of the subgroups had a count = 0. Wilcoxon rank sum test was performed to compare continuous variables between the 2 subgroups (CCS and ACS patients). A p-value < 0.05 was judged statistically significant.
Kaplan–Meier estimators with 95% confidence intervals (CI) were used to compare 48-month survival curves for various endpoints between the 2 subgroups (CCS and ACS patients). If a particular endpoint occurred for a given patient more than once in a 48-month follow-up, then survival time was treated as the time until the first occurrence of this event. Notably, when considering MACE (a composite endpoint), the survival time was defined as the period leading up to the occurrence of the first event among the following: cardiac death, MI, or TLR.
Univariable and multivariable Cox regression analyses (utilizing the Cox proportional hazards model) were conducted to assess the differences in survival rates among the groups. The multivariable Cox regression model was selected through stepwise selection, employing a backward elimination algorithm with a significance threshold set at 0.1. The outcomes, including the Hazard Ratio (HR) and corresponding 95% confidence intervals for HR, were subsequently reported.
Statistical analyses were conducted using R software version 4.2.1 (23 June 2022) (“Funny-Looking Kid”, Copyright 2022; The R Foundation for Statistical Computing Platform: x86_64-w64-mingw32/x64 (64-bit)) [14].

3. Results

3.1. Baseline Characteristics

In the reporting time frame, we retrieved data on 872 PCI procedures. For the final analysis, we included 232 patients among whom 282 Alex Plus stents had been implanted, as described previously in detail [16]. We identified 88 patients with ACS (STEMI—32, NSTEMI—26, UA—30) and 144 patients with CCS (Figure 1).
The mean ACS population age was 67 ± 13 years old, and 32% of the subjects were females. In the ACS group, there were six cases (6.8%) of cardiogenic shock. The patients with ACS were characterized by lower rates of arterial hypertension (85.2% vs. 95.8%, p = 0.004), dyslipidemia (67% vs. 81.9%, p = 0.01), prior MI (34.1% vs. 57.6%, p < 0.001), and prior PCI (35.2% vs. 68.8%, p < 0.001) (Table 1). The patients with ACS had higher white blood cell counts and, by definition, higher levels of cardiac necrosis enzymes (Table 2).

3.2. Procedure Characteristics

We found no significant differences between the ACS and CCS patients, taking into consideration lesion location as well as lesion type. Mostly treated lesions were located in the right coronary artery (ACS vs. CCS: 36.4% vs. 40.3%, p = 0.305), followed by the left anterior descending artery (33.0% vs. 29.9%, p = 0.305) and left circumflex artery (26.1% vs. 26.4%, p = 0.305). The lesions being treated with PCI were complex. Type C lesions were treated in 37.5% of ACS cases and 40.3% of CCS cases (p = 0.495). Coronary bifurcations were treated in 9.1% and 10.4% of the ACS and CCS cases, respectively (p = 0.743). The mean SYNTAX score was higher for the ACS patients (16.0 ± 8.4 vs. 12.9 ± 8.6, p = 0.008) (Table 3).
In the ACS patients, transfemoral access was used more frequently (27.3% vs. 13.2%, p = 0.013), but there were no differences when a 6F guiding catheter was used (98.9% vs. 93.8%, p = 0.094). Lesions were less frequently predilated in the ACS group (53.4% vs. 66.7%, p = 0.043), and post-dilatations were performed at similar rates (38.6% vs. 37.5%, p = 0.852). The mean nominal parameters of the Alex Plus stent did not differ significantly between the groups. Device success was 100% in the ACS group and 99.3% in the CCS group (in one case, a second stent needed to be used due to heavy calcifications). Additional stents were deployed in 37.5% of the ACS cases and 39.6% of the CCS cases (p = 0.803). Coronary dissections were comparable between groups (5.7% vs. 7.6%, p = 0.568) (Table 3).
The drugs administered upon discharge are shown in Table 4. All patients received acetylsalicylic acid and P2Y12 inhibitors. In the ACS group, 88.6% of patients received clopidogrel and 11.4% received ticagrelor. ACS patients received hypoglycemic drugs less frequently (18.2% vs. 31.9%, p = 0.022).

3.3. 4-Year Outcomes

The incidences of MACE, death, cardiac death, MI, and TLR at 12, 24, 36, and 48 months for the whole population were published previously [16]. At 48 months, among the ACS patients, the rates of MACE, death, cardiac death, MI, and TLR were 23.9%, 11.4%, 7.9%, 9.1%, and 10.2%, respectively (Table 5). The reasons for cardiac death were heart failure deterioration (n = 5), cardiogenic shock due to MI (n = 1), and sudden cardiac death (n = 1). No stent thrombosis cases were reported. Figure 2 shows that there were no statistically significant differences between the ACS and CCS patients in terms of the analyzed endpoints at 4 years.

3.4. Cox Analysis

Finally, we analyzed predictive factors for MACE and TLR in the ACS subgroup at 48 months. The multivariable analyses results are depicted in Table 6 for MACE and Table 7 for TLR (univariable analyses are presented in Supplementary Tables S1 and S2).
The multivariable Cox regression revealed that the statistically significant MACE predictors were massive calcifications in the coronary arteries (HR 9.0, 95% CI 1.75–46.3, p = 0.009), post-dilatation (HR 3.78, 95% CI 1.28–11.2, p = 0.016), prior CABG (HR 6.64, 95% CI 1.62–27.1, p = 0.008), VKA use (HR 5.99, 95% CI 1.29–27.8, p = 0.022), and rivaroxaban use (HR 51.7, 95% CI 4.48–596, p = 0.002), whereas the TLR predictors were massive calcifications in the coronary arteries (HR 10.2, 95% CI 1.72–60.9, p = 0.011), second stent implantation (HR 11.8, 95% CI 1.22–114, p = 0.033), and a SYNTAX score of 23–32 points (HR 6.79, 95% CI 1.12–41.1, p = 0.037).

4. Discussion

This study’s findings show that Alex Plus was effective and safe in a contemporary cohort of real-world ACS patients undergoing primary PCI. PCI with Alex Plus was characterized by rare periprocedural complications and device success over 99%. The outcomes were comparable between the ACS and CCS patients, with a trend of lower TLR in the ACS patients at 4 years. This was mainly driven by the complexity of the lesions and patients. In CCS, there were more complex high-risk index procedure (CHIP) patients (higher calcification, more bifurcations, and more complex lesions).
Since the development of coronary stents in the late 1980s, constant technical and device-related improvements have been applied to diminish the rate of adverse events, especially those directly related to the stent. Contemporary DESs are designed with thinner struts (130–149 μm to 60–81 μm), and the transition in the stent platform from stainless steel to chromium alloys has decreased periprocedural and long-term complications. Thin-strut stents result in less artery injury and inflammation, thrombus formation, and neointimal proliferation than thick-strut stents [22]. Moreover, thin-strut stents are characterized by better deliverability. On the other hand, thin-strut stents might induce lower radial force and have a larger likelihood of stent deformation when advancing through tortuous anatomy. These issues highlight the significance of verifying the acquisition of results in contemporary cohorts of patients in real-world practice [23].
Some contemporary DESs release the drug from a bioresorbable polymer (BP). This offers the possibility of releasing the drug in a controlled manner and then dissolving the polymer material. This, at least theoretically, might decrease the stimulus for a persistent inflammatory state predisposing one to future ischemic events such as in-stent thrombosis [24]. In the HATTRICK-OCT trial, BP-SES enabled slightly better stent strut coverage at 3 months compared to a durable polymer (DP) zotarolimus-eluting stent (ZES) [25]. In a recent meta-analysis of patients undergoing PCI for unprotected left main coronary artery disease using ultrathin stents (with struts thinner than 81 μm), comparable outcomes in terms of MACE were observed between those treated with BP and DP stents. There were no significant variations in in-stent thrombosis between the two groups. Notably, patients with bifurcation lesions who received two BP drug-eluting stents exhibited improved results, including lower rates of MACE and target vessel revascularization (TVR). These results might suggest that minimizing persistent inflammatory stimuli is crucial in more complex and thrombogenic settings, such as those relating to ACS or bifurcation lesions [26]. The TARGET AC study revealed that patients with BP DES, after stopping dual antiplatelet therapy, exhibited a trend of lower rates of target vessel MI and ischemia-driven revascularization [27]. Nevertheless, in the most recent study, Bioflow-DAPT, no significant difference between BP and DP DES was observed [28]. Investigators assessed the effectiveness and safety of BP SES with DP ZES in high-bleeding-risk patients receiving 30-day dual antiplatelet therapy. At 12 months, the primary endpoint (cardiac death, MI, or in-stent thrombosis) was reported for 3.6% of the BP SES patients and 3.4% of the DP ZES patients (p < 0.0001).
Despite the all-comer nature of the study, the periprocedural complication rates in this study were low. One explanation for this phenomenon might be that transradial intervention was used in 73% of the ACS patients. Transradial access is well known to be associated with a lower risk of adverse clinical events than femoral access, particularly in MI patients [29].
At 12 months, the cardiac death, TLR, MI, and MACE rates were 4.5%, 6.8%, 4.5%, and 12.5%, respectively. The rates increased at 48 months to 7.9%, 10.2%, 9.1%, and 23.9%, respectively. These results are comparable to those reported in the literature.
Araujo et al. reported data on SESs with a strut thickness of 75 μm (Inspiron, Scitech Medical, Goiás, Brazil) vs. other contemporary DESs in STEMI patients [30]. At 17 months, the MACE rates were 14.4% for Inspiron and 16.1% for other DESs. Also, the authors reported high rates of stent thrombosis: 1.7% for Inspiron and 2.1% for other DES. Jimenez et al. compared BP SESs (Ultimaster, Terumo, Tokyo, Japan) and DP EESs (Xience DES, Abbott Vascular, Abbott Park, IL, USA) used in ACS patients from the CENTURY II study [31]. At 24 months, the cardiac death rate was 0 vs. 2.1% (p = 0.10), the MI rate was 2.3% vs. 4.3% (p = 0.38), and the TLR rate was 5.5% vs. 3.6% (p = 0.45). Iglesias et al. compared BP SESs (Orsiro, Biotronik AG, Baar, Switzerland) and DP EESs (Xience, Abbott Vascular, Abbott Park, IL, USA) used in ACS patients from a BIOSCIENCE study [32]. At 5 years, the all-cause death rate was 13.3% vs. 9.7% (p = 0.089), the cardiac death rate was 8% vs. 7% (p = 0.664), the MI rate was 9.9% vs. 11.5% (p = 0.334), the TLR rate was 9.5% vs. 9% (p = 0.742), and the definite stent thrombosis rate was 1.4% vs. 1% (p = 0.573). Tousek et al. reported data from the PRAGUE-22 study on ACS patients. In the Xience group, at 12 months, the TLR rate was 4%, and in the Magmaris group, the TLR was 12%, with a stent thrombosis rate of 4% [33].
In contrast, ACS patients from BIOFLOW-V (BP SES vs. DP EES) were characterized by very low all-cause and cardiac death (1.2–1.4% and 0–1%), TLR (3.5% vs. 3.9%, p = 0.823), target vessel MI (3.5% vs. 9.7%, p = 0.003), and MACE (7% vs. 11.9%, p = 0.050) rates [34]. Also, an interesting analysis was performed by Hemetsberger et al., who presnted pooled PCI results from the BIOFLOW II, IV, and V studies considering complex vs. non-complex PCI. At 3 years, target lesion failure was 14.6% for complex PCI and 8.1% for non-complex PCI (p < 0.001), and target vessel MI was 10.2% vs. 4.4% (p < 0.001), respectively [35].
Finally, we identified predicting factors of MACE and TLR. They are well known, like calcifications or higher SYNTAX scores. Nevertheless, anticoagulant use (VKA and rivaroxaban) had a strikingly high impact. This result might also be associated with the fact that 1/3 of our population consisted of high-bleeding-risk patients.

Study Limitations

This study has some inherent limitations common to observational studies, where the treatment choice is based on the operator’s preference. The absence of randomization could potentially introduce selection bias, although this was somewhat alleviated by enrolling patients consecutively. Furthermore, the relatively small size of the study cohort and limitations in collecting follow-up data might have had an impact on the findings. Additionally, the absence of a formal calculation for the sample size could be a factor that influenced the results.

5. Conclusions

The study findings show that Alex Plus was effective and safe in a contemporary cohort of real-world ACS patients undergoing primary PCI. The outcomes were comparable between the ACS and CCS patients, with a trend of lower TLR in the ACS patients at 4 years.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/jpm13111573/s1. Table S1: Univariable Cox regression for MACE; Table S2: Univariable Cox regression for TLR.

Author Contributions

Conceptualization, M.T. and J.B.; methodology, M.T. and J.B.; investigation, P.B., M.T. and A.K.; data curation, J.B. and R.J.G.; writing—original draft preparation, M.T. and J.B.; writing—review and editing, M.T.; supervision, R.J.G. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study protocol was reviewed and approved by the Independent Ethics Committee of the Central Clinical Hospital of the Ministry of Interior and Administration in Warsaw (No 64/2020 of 22 April 2020).

Informed Consent Statement

Patient consent was waived due to the retrospective nature of the study.

Data Availability Statement

Data are available from the corresponding author on request.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Thygesen, K.; Alpert, J.S.; Jaffe, A.S.; Chaitman, B.R.; Bax, J.J.; Morrow, D.A.; White, H.D.; Executive Group on behalf of the Joint European Society of Cardiology (ESC)/American College of Cardiology (ACC)/American Heart Association (AHA)/World Heart Federation (WHF) Task Force for the Universal Definition of Myocardial Infarction. Fourth universal definition of myocardial infarction (2018). Eur. Heart J. 2019, 40, 237–269. [Google Scholar] [CrossRef] [PubMed]
  2. Higuma, T.; Soeda, T.; Abe, N.; Yamada, M.; Yokoyama, H.; Shibutani, S.; Vergallo, R.; Minami, Y.; Ong, D.S.; Lee, H.; et al. A Combined Optical Coherence Tomography and Intravascular Ultrasound Study on Plaque Rupture, Plaque Erosion, and Calcified Nodule in Patients With ST-Segment Elevation Myocardial Infarction: Incidence, Morphologic Characteristics, and Outcomes After Percutaneous Coronary Intervention. JACC Cardiovasc. Interv. 2015, 8, 1166–1176. [Google Scholar] [CrossRef] [PubMed]
  3. Achim, A.; Marc, M.; Ruzsa, Z. Surgical Turned-Downed CHIP Cases-Can PCI Save the Day? Front. Cardiovasc. Med. 2022, 9, 872398. [Google Scholar] [CrossRef] [PubMed]
  4. Omer, M.A.; Tyler, J.M.; Henry, T.D.; Garberich, R.; Sharkey, S.W.; Schmidt, C.W.; Henry, J.T.; Eckman, P.; Megaly, M.; Brilakis, E.S.; et al. Clinical Characteristics and Outcomes of STEMI Patients With Cardiogenic Shock and Cardiac Arrest. JACC Cardiovasc. Interv. 2020, 13, 1211–1219. [Google Scholar] [CrossRef]
  5. Collet, J.P.; Thiele, H.; Barbato, E.; Barthelemy, O.; Bauersachs, J.; Bhatt, D.L.; Dendale, P.; Dorobantu, M.; Edvardsen, T.; Folliguet, T.; et al. 2020 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation. Eur. Heart J. 2021, 42, 1289–1367. [Google Scholar] [CrossRef]
  6. Bil, J.; Gil, R.J.; Kern, A.; Pawlowski, T.; Seweryniak, P.; Sliwinski, Z. Novel sirolimus-eluting stent Prolim(R) with a biodegradable polymer in the all-comers population: One year clinical results with quantitative coronary angiography and optical coherence tomography analysis. BMC Cardiovasc. Disord. 2015, 15, 150. [Google Scholar] [CrossRef]
  7. Byrne, R.A.; Rossello, X.; Coughlan, J.J.; Barbato, E.; Berry, C.; Chieffo, A.; Claeys, M.J.; Dan, G.A.; Dweck, M.R.; Galbraith, M.; et al. 2023 ESC Guidelines for the management of acute coronary syndromes. Eur. Heart J. 2023, 44, 3720–3826. [Google Scholar] [CrossRef]
  8. Tada, T.; Byrne, R.A.; Simunovic, I.; King, L.A.; Cassese, S.; Joner, M.; Fusaro, M.; Schneider, S.; Schulz, S.; Ibrahim, T.; et al. Risk of stent thrombosis among bare-metal stents, first-generation drug-eluting stents, and second-generation drug-eluting stents: Results from a registry of 18,334 patients. JACC Cardiovasc. Interv. 2013, 6, 1267–1274. [Google Scholar] [CrossRef]
  9. Canfield, J.; Totary-Jain, H. 40 Years of Percutaneous Coronary Intervention: History and Future Directions. J. Pers. Med. 2018, 8, 33. [Google Scholar] [CrossRef]
  10. Liu, H.L.; Jin, Z.G.; Yang, S.L.; Han, W.; Jing, Q.M.; Zhang, L.; Luo, J.P.; Ma, D.X.; Liu, Y.; Yang, L.X.; et al. Five-year outcomes of ST-elevation myocardial infarction versus non-ST-elevation acute coronary syndrome treated with biodegradable polymer-coated sirolimus-eluting stents: Insights from the CREATE trial. J. Cardiol. 2017, 69, 149–155. [Google Scholar] [CrossRef]
  11. Gherasie, F.A.; Valentin, C.; Busnatu, S.S. Is There an Advantage of Ultrathin-Strut Drug-Eluting Stents over Second- and Third-Generation Drug-Eluting Stents? J. Pers. Med. 2023, 13, 753. [Google Scholar] [CrossRef]
  12. Leone, A.; Simonetti, F.; Avvedimento, M.; Angellotti, D.; Immobile Molaro, M.; Franzone, A.; Esposito, G.; Piccolo, R. Ultrathin Struts Drug-Eluting Stents: A State-of-the-Art Review. J. Pers. Med. 2022, 12, 1378. [Google Scholar] [CrossRef] [PubMed]
  13. Schmidt, T.; Abbott, J.D. Coronary Stents: History, Design, and Construction. J. Clin. Med. 2018, 7, 126. [Google Scholar] [CrossRef] [PubMed]
  14. Jezewski, M.P.; Kubisa, M.J.; Eyileten, C.; De Rosa, S.; Christ, G.; Lesiak, M.; Indolfi, C.; Toma, A.; Siller-Matula, J.M.; Postula, M. Bioresorbable Vascular Scaffolds-Dead End or Still a Rough Diamond? J. Clin. Med. 2019, 8, 2167. [Google Scholar] [CrossRef] [PubMed]
  15. Achim, A.; Alampi, C.; Krivoshei, L.; Leibundgut, G. In vitro effect of intravascular lithotripsy on the polymer of a drug-eluting stent. EuroIntervention 2022, 18, e333–e334. [Google Scholar] [CrossRef]
  16. Tyczyński, M.; Kern, A.; Buller, P.; Wańha, W.; Gil, R.J.; Bil, J. Clinical Outcomes and Prognostic Factors in Complex, High-Risk Indicated Procedure (CHIP) and High-Bleeding-Risk (HBR) Patients Undergoing Percutaneous Coronary Intervention with Sirolimus-Eluting Stent Implantation: 4-Year Results. J. Clin. Med. 2023, 12, 5313. [Google Scholar] [CrossRef]
  17. Buszman, P.P.; Michalak, M.J.; Pruski, M.; Fernandez, C.; Jelonek, M.; Janas, A.; Savard, C.; Gwiazdowska-Nowotka, B.; Zurakowski, A.; Wojakowski, W.; et al. Comparable vascular response of a new generation sirolimus eluting stents when compared to fluoropolymer everolimus eluting stents in the porcine coronary restenosis model. Cardiol. J. 2016, 23, 657–666. [Google Scholar] [CrossRef]
  18. Dobrolinska, M.; Gasior, P.; Roleder, T.; Roleder-Dylewska, M.; Smolka, G.; Ochala, A.; Kedhi, E.; Wojakowski, W. Short-term healing response after implantation of the thin-strut, fast-releasing sirolimus-eluting biodegradable polymer-coated Alex Plus stent: Optical coherence tomography study. Postepy Kardiol. Interwencyjnej 2020, 16, 187–191. [Google Scholar] [CrossRef]
  19. Ryan, T.J.; Faxon, D.P.; Gunnar, R.M.; Kennedy, J.W.; King, S.B., 3rd; Loop, F.D.; Peterson, K.L.; Reeves, T.J.; Williams, D.O.; Winters, W.L., Jr.; et al. Guidelines for percutaneous transluminal coronary angioplasty. A report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Subcommittee on Percutaneous Transluminal Coronary Angioplasty). Circulation 1988, 78, 486–502. [Google Scholar] [CrossRef]
  20. Farooq, V.; van Klaveren, D.; Steyerberg, E.W.; Meliga, E.; Vergouwe, Y.; Chieffo, A.; Kappetein, A.P.; Colombo, A.; Holmes, D.R., Jr.; Mack, M.; et al. Anatomical and clinical characteristics to guide decision making between coronary artery bypass surgery and percutaneous coronary intervention for individual patients: Development and validation of SYNTAX score II. Lancet 2013, 381, 639–650. [Google Scholar] [CrossRef]
  21. Lancellotti, P.; Zamorano, J.; Habib, G.; Badano, L. The EACVI Textbook of Echocardiography; Oxford University Press: Oxford, UK, 2016. [Google Scholar]
  22. Kolandaivelu, K.; Swaminathan, R.; Gibson, W.J.; Kolachalama, V.B.; Nguyen-Ehrenreich, K.L.; Giddings, V.L.; Coleman, L.; Wong, G.K.; Edelman, E.R. Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings. Circulation 2011, 123, 1400–1409. [Google Scholar] [CrossRef] [PubMed]
  23. Kawamura, A.; Egami, Y.; Kawanami, S.; Sugae, H.; Ukita, K.; Nakamura, H.; Matsuhiro, Y.; Yasumoto, K.; Tsuda, M.; Okamoto, N.; et al. Preferable vascular healing of ultrathin strut biodegradable-polymer sirolimus-eluting stents in patients with acute coronary syndrome. Cardiovasc. Interv. Ther. 2022, 37, 681–690. [Google Scholar] [CrossRef] [PubMed]
  24. Matsuhiro, Y.; Egami, Y.; Okamoto, N.; Kusuda, M.; Sakio, T.; Nohara, H.; Sugae, H.; Kawanami, S.; Kawamura, A.; Ukita, K.; et al. Early vascular healing of ultra-thin strut polymer-free sirolimus-eluting stents in acute coronary syndrome: USUI-ACS study. Cardiovasc. Interv. Ther. 2023, 38, 55–63. [Google Scholar] [CrossRef] [PubMed]
  25. Karjalainen, P.P.; Varho, V.; Nammas, W.; Mikkelsson, J.; Pietila, M.; Ylitalo, A.; Airaksinen, J.K.; Sia, J.; Nyman, K.; Biancari, F.; et al. Early neointimal coverage and vasodilator response following biodegradable polymer sirolimus-eluting vs. durable polymer zotarolimus-eluting stents in patients with acute coronary syndrome -HATTRICK-OCT trial. Circ. J. 2015, 79, 360–367. [Google Scholar] [CrossRef]
  26. Iannaccone, M.; Barbero, U.; De Benedictis, M.; Imori, Y.; Quadri, G.; Trabattoni, D.; Ryan, N.; Venuti, G.; Montabone, A.; Wojakowski, W.; et al. Comparison of bioresorbable vs durable polymer drug-eluting stents in unprotected left main (from the RAIN-CARDIOGROUP VII Study). BMC Cardiovasc. Disord. 2020, 20, 225. [Google Scholar] [CrossRef]
  27. Saito, Y.; Wijns, W.; Baumbach, A.; Xu, B.; Kelbaek, H.; Zheng, M.; Morel, M.A.; Anderson, R.; Schachinger, V.; Lansky, A.; et al. Differential impact of abluminal groove-filled biodegradable-polymer sirolimus-eluting stent versus durable-polymer everolimus-eluting stent on and off dual antiplatelet therapy. Catheter. Cardiovasc. Interv. 2022, 99, 357–365. [Google Scholar] [CrossRef]
  28. Valgimigli, M.; Wlodarczak, A.; Tolg, R.; Merkely, B.; Kelbaek, H.; Legutko, J.; Galli, S.; Godin, M.; Toth, G.G.; Lhermusier, T.; et al. Biodegradable-Polymer or Durable-Polymer Stents in Patients at High Bleeding Risk: A Randomized, Open-Label Clinical Trial. Circulation 2023, 148, 989–999. [Google Scholar] [CrossRef]
  29. Jolly, S.S.; Yusuf, S.; Cairns, J.; Niemela, K.; Xavier, D.; Widimsky, P.; Budaj, A.; Niemela, M.; Valentin, V.; Lewis, B.S.; et al. Radial versus femoral access for coronary angiography and intervention in patients with acute coronary syndromes (RIVAL): A randomised, parallel group, multicentre trial. Lancet 2011, 377, 1409–1420. [Google Scholar] [CrossRef]
  30. Araujo, G.N.; Machado, G.P.; Moura, M.; Silveira, A.D.; Bergoli, L.C.; Fuchs, F.C.; Goncalves, S.C.; Wainstein, R.V.; Lemos, P.A.; Quadros, A.S.; et al. Real-World Assessment of an Ultrathin Strut, Sirolimus-Eluting Stent in Patients with ST-Elevation Myocardial Infarction Submitted to Primary Percutaneous Coronary Intervention (INSTEMI Registry). Arq. Bras. Cardiol. 2023, 120, e20220594. [Google Scholar] [CrossRef]
  31. Jimenez, V.A.; Iniguez, A.; Baz, J.A.; Valdes, M.; Ortiz, A.; Vuilliomenet, A.; Mainar, V.; Dudek, D.; Banai, S.; Tuller, D.; et al. A randomized comparison of novel bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with acute coronary syndromes: The CENTURY II high risk ACS substudy. Cardiovasc. Revasc. Med. 2016, 17, 355–361. [Google Scholar] [CrossRef]
  32. Iglesias, J.F.; Heg, D.; Roffi, M.; Degrauwe, S.; Tuller, D.; Muller, O.; Brinkert, M.; Cook, S.; Weilenmann, D.; Kaiser, C.; et al. Five-Year Outcomes With Biodegradable-Polymer Sirolimus-Eluting Stents Versus Durable-Polymer Everolimus-Eluting Stents in Patients With Acute Coronary Syndrome: A Subgroup Analysis of the BIOSCIENCE Trial. Cardiovasc. Revasc. Med. 2022, 34, 3–10. [Google Scholar] [CrossRef] [PubMed]
  33. Tousek, P.; Lazarak, T.; Varvarovsky, I.; Novackova, M.; Neuberg, M.; Kocka, V. Comparison of a Bioresorbable, Magnesium-Based Sirolimus-Eluting Stent with a Permanent, Everolimus-Eluting Metallic Stent for Treating Patients with Acute Coronary Syndrome: The PRAGUE-22 Study. Cardiovasc. Drugs Ther. 2022, 36, 1129–1136. [Google Scholar] [CrossRef] [PubMed]
  34. Roguin, A.; Kandzari, D.E.; Marcusohn, E.; Koolen, J.J.; Doros, G.; Massaro, J.M.; Garcia-Garcia, H.M.; Bennett, J.; Gharib, E.G.; Cutlip, D.E.; et al. Subgroup Analysis Comparing Ultrathin, Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin, Durable Polymer Everolimus-Eluting Stents in Acute Coronary Syndrome Patients. Circ. Cardiovasc. Interv. 2018, 11, e007331. [Google Scholar] [CrossRef] [PubMed]
  35. Hemetsberger, R.; Abdelghani, M.; Toelg, R.; Garcia-Garcia, H.M.; Farhan, S.; Mankerious, N.; Elbasha, K.; Allali, A.; Windecker, S.; Lefevre, T.; et al. Complex vs. non-complex percutaneous coronary intervention with newer-generation drug-eluting stents: An analysis from the randomized BIOFLOW trials. Clin. Res. Cardiol. 2022, 111, 795–805. [Google Scholar] [CrossRef]
Figure 1. A flow chart of the study. ACS—acute coronary syndrome; CCS—chronic coronary syndrome; STEMI—ST-elevation myocardial infarction; NSTEMI—non-ST-elevation myocardial infarction; UA—unstable angina.
Figure 1. A flow chart of the study. ACS—acute coronary syndrome; CCS—chronic coronary syndrome; STEMI—ST-elevation myocardial infarction; NSTEMI—non-ST-elevation myocardial infarction; UA—unstable angina.
Jpm 13 01573 g001
Figure 2. Kaplan–Meier curves regarding event-free survival in ACS and CCS subgroups. ACS—acute coronary syndrome; CCS—chronic coronary syndrome; MACE—major adverse cardiovascular events; MI—myocardial infarction; TLR—target lesion revascularization.
Figure 2. Kaplan–Meier curves regarding event-free survival in ACS and CCS subgroups. ACS—acute coronary syndrome; CCS—chronic coronary syndrome; MACE—major adverse cardiovascular events; MI—myocardial infarction; TLR—target lesion revascularization.
Jpm 13 01573 g002
Table 1. Baseline characteristics.
Table 1. Baseline characteristics.
VariableTotal Population
N = 232 (%)
ACS
N = 88 (%)
CCS
N = 144 (%)
p
Sex: female64 (27.6)28 (32)36 (25)0.260
Age (years)68 ± 1167 ± 1368 ± 90.788
Acute coronary syndrome type upon presentation
Unstable angina30 (12.9)30 (34.2)0<0.001
Non-ST-elevation MI26 (11.2)26 (29.5)0
ST-elevation MI32 (13.8)32 (36.3)0
Cardiogenic shock6 (2.6)6 (6.8)00.003
Arterial hypertension213 (91.8)75 (85.2)138 (95.8)0.004
Type 2 diabetes 97 (41.8)32 (36.4)65 (45.1)0.189
Dyslipidemia177 (76.3)59 (67.0)118 (81.9)0.010
Prior myocardial infarction113 (48.7)30 (34.1)83 (57.6)<0.001
Prior PCI130 (56.0)31 (35.2)99 (68.8)<0.001
Prior CABG22 (9.5)7 (8.0)15 (10.4)0.535
Chronic kidney disease42 (18.1)20 (22.7)22 (15.3)0.153
Prior stroke17 (7.3)8 (9.1)9 (6.2)0.420
Peripheral artery disease25 (10.8)8 (9.1)17 (11.8)0.518
Chronic obstructive pulmonary disease13 (5.6)6 (6.8)7 (4.9)0.565
Echocardiographic parameters
Left-ventricular end-diastolic diameter (mm)50.4 ± 9.050.6 ± 7.350.2 ± 10.20.665
Intraventricular septal diameter (mm)11.4 ± 2.111.2 ± 2.511.6 ± 1.80.197
Posterior wall diastolic diameter (mm)10.5 ± 1.610.2 ± 1.810.7 ± 1.40.124
left atrium (mm)40.4 ± 5.939.4 ± 5.941.3 ± 5.80.033
TAPSE (mm)22.0 ± 4.321.0 ± 3.222.0 ± 3.80.609
LVEF [%]49.5 ± 10.548.0 ± 11.150.6 ± 9.90.075
Severe mitral insufficiency6 (3.1)3 (3.5)3 (2.8)0.999
Severe aortic insufficiency1 (0.5)1 (1.2)0 (0.0)0.438
Severe aortic stenosis4 (2.1)1 (1.2)3 (2.8)0.633
ACS—acute coronary syndrome; CCS—chronic coronary syndrome; MI—myocardial infarction; CABG—coronary artery bypass grafting; LVEF—left-ventricular ejection fraction; PCI—percutaneous coronary intervention; TAPSE—tricuspid annular plane systolic excursion.
Table 2. Laboratory results.
Table 2. Laboratory results.
VariableTotal Population
N = 232
ACS
N = 88 (%)
CCS
N = 144 (%)
p
White blood cells (109/L)8.5 ± 2.79.7 ± 3.07.8 ± 2.1<0.002
Hemoglobin (g/dL)13.4 ± 1.713.4 ± 1.713.3 ± 1.60.861
Red blood cells (1012/L)4.4 ± 0.54.5 ± 0.54.4 ± 0.50.477
Platelets (109/L)222.9 ± 65226.7 ± 67.2220.3 ± 63.50.580
Glucose (mg/dL)136.4 ± 64.9147.6 ± 72.1125.4 ± 55.10.005
HbA1c (%)6.3 (6.0–7.3)6.3 (5.8–7.3)6.3 (6.1–7.3)0.592
Total cholesterol (mg/dL)163.9 ± 50.9170.5 ± 52.2157.5 ± 49.00.067
HDL (mg/dL)45.7 ± 14.646.2 ± 16.745.2 ± 12.30.764
LDL (mg/dL)89.8 ± 40.594.7 ± 43.085.0 ± 37.50.135
Triglycerides (mg/dL)142 ± 33.9147.2 ± 126.3137.0 ± 141.40.564
Creatine (mg/dL)1.1 ± 0.71.2 ± 1.01.1 ± 0.40.244
eGFR (mL/min/1.73 m2)70.5 ± 23.268.5 ± 25.971.9 ± 21.10.269
Troponin I upon admission (ng/mL)108 (15.8–235)281.4 (50.5–213)44 (9.5–119.5)<0.001
Troponin I max (ng/mL)1110 (49.8–11,573)5294 (688–32,561)53.8 (14–538)<0.001
CK at admission (IU/L)134.5 (84–326)232 (124–626)85 (67–121)<0.001
CK max (IU/L)173 (90–473)295 (164–963)89 (67–152)<0.001
CK-MB at admission (IU/L)18 (13.5–30)23 (17–47)15 (12–18.2)<0001
CK-MB max (U/L)22.5 (15–48.5)41 (22–116.5)16 (13–22.8)<0.001
Results are presented as mean ± standard deviation or median with interquartile range; ACS—acute coronary syndrome; CCS—chronic coronary syndrome; CK—creatine kinase; HDL—high-density lipoprotein; LDL—low-density lipoprotein.
Table 3. Periprocedural characteristics.
Table 3. Periprocedural characteristics.
VariableTotal Population
N = 232 (%)
ACS
N = 88 (%)
CCS
N = 144 (%)
p
Coronary artery with the target lesion
LM9 (3.9)5 (5.7)4 (2.8)0.305
LAD72 (31)29 (33.0)43 (29.9)
LCx61 (26.3)23 (26.1)38 (26.4)
RCA90 (38.8)32 (36.4)58 (40.3)
VG6 (2.6)5 (5.7)1 (0.7)
Type of the target lesion
A38 (16.4)13 (14.8)25 (17.4)0.495
B166 (28.4)30 (34.1)36 (25.0)
B237 (15.9)12 (13.6)25 (17.4)
C91 (39.2)33 (37.5)58 (40.3)
Heavy calcification18 (7.8)4 (4.5)14 (9.7)0.153
Coronary bifurcation23 (9.9)8 (9.1)15 (10.4)0.743
SYNTAX13.9 ± 8.716.0 ± 8.412.9 ± 8.60.008
SYNTAX II PCI32.9 ± 11.035.6 ± 10.131.6 ± 11.20.003
SYNTAX II CABG29.1 ± 10.829.9 ± 10.528.6 ± 11.10.491
EuroScore II1.6 (0.9–3.3)2.5 (1.3–4.3)1.3 (0.8–2.5)<0.001
Lesion pre-dilatation143 (61.6)47 (53.4)96 (66.7)0.043
Stent diameter (mm)3.2 ± 0.53.2 ± 0.53.1 ± 0.50.069
Stent length (mm)21.2 ± 10.921.9 ± 1220.8 ± 10.20.821
Stent pressure (atm)15.3 ± 2.715.5 (2.6)15.2 (2.7)0.578
2nd stent implantation90 (39)33 (37.5)57 (39.6)0.803
Stent post-dilatation88 (37.9)34 (38.6)54 (37.5)0.852
Access site *
Transradial193 (83.2)64 (72.7)129 (89.3)0.013
Transfemoral43 (18.5)24 (27.3)19 (13.2)
Guiding catheter *
6F222 (95.7)87 (98.9)135 (93.8)0.094
7F11 (4.7)1 (1.1)10 (6.9)
Coronary dissection16 (6.9)5 (5.7)11 (7.6)0.568
MI type 4a5 (2.2)05 (3.5)0.159
* more than one access or catheter were used during the procedure; ACS—acute coronary syndrome; CCS—chronic coronary syndrome; LM—left main; LAD—left anterior descending artery; LCx—left circumflex artery; MI—myocardial infarction; RCA—right coronary artery; VG—vein graft.
Table 4. Drugs administered upon discharge.
Table 4. Drugs administered upon discharge.
VariableTotal Population
N = 232 (%)
ACS
N = 88 (%)
CCS
N = 144 (%)
p
Acetylsalicylic acid232 (100)88 (100.0)144 (100.0)-
P2Y12
Clopidogrel214 (92.2)78 (88.6)136 (94.4)0.065
Prasugrel1 (0.4)01 (0.7)
Ticagrelor17 (7.3)10 (11.4)7 (4.9)
Beta-blocker223 (96.1)84 (95.5)139 (96.5)0.733
Ca-blocker53 (22.8)15 (17.0)38 (26.4)0.100
Angiotensin-converting enzyme inhibitor190 (81.9)74 (84.1)116 (80.6)0.497
Angiotensin receptor blocker36 (15.5)10 (11.4)26 (18.1)0.172
Diuretic125 (53.9)48 (54.5)77 (53.5)0.874
Mineralocorticoid receptor antagonist48 (20.7)23 (26.1)25 (17.4)0.109
Nitrates13 (5.6)3 (3.4)10 (6.9)0.380
Vitamin K antagonist17 (7.3)8 (9.1)9 (6.2)0.420
Non-vitamin K oral anticoagulant11 (4.7)1 (1.1)10 (7.0)0.265
Statin230 (99.1)88 (100.0)142 (98.6)0.527
Hypoglycemic medications62 (26.7)16 (18.2)46 (31.9)0.022
Insulin33 (14.2)16 (18.2)17 (11.8)0.177
ACS—acute coronary syndrome; CCS—chronic coronary syndrome.
Table 5. Study endpoints arranged by year for ACS patients.
Table 5. Study endpoints arranged by year for ACS patients.
YearDeathCardiac DeathTLRMIMACE
15 (5.7)4 (4.5)6 (6.8)4 (4.5)11 (12.5)
26 (6.8)4 (4.5)7 (7.9)4 (4.5)12 (13.6)
38 (9.1)6 (6.8)8 (9.1)4 (4.5)15 (17.1)
410 (11.4)7 (7.9)9 (10.2)8 (9.1)21 (23.9)
n (%). MACE—major adverse cardiovascular events; MI—myocardial infarction; TLR—target lesion revascularization.
Table 6. Multivariable Cox analysis: major adverse cardiovascular events.
Table 6. Multivariable Cox analysis: major adverse cardiovascular events.
VariableMultivariable Analysis for MACE
HR95% CIp
High bleeding risk1.630.44–6.020.461
Calcification9.001.75–46.30.009
Post-dilatation3.781.28–11.20.016
Prior coronary artery bypass grafting6.641.62–27.10.008
VKA—vitamin K antagonist use5.991.29–27.80.022
Rivaroxaban use51.74.48–5960.002
Table 7. Multivariable Cox analysis: target lesion revascularization.
Table 7. Multivariable Cox analysis: target lesion revascularization.
VariableMultivariable Analysis for TLR
HR95% CIp
Calcifications10.21.72–60.90.011
2nd stent11.81.22–1140.033
SYNTAX 23–326.791.12–41.10.037
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Tyczynski, M.; Kern, A.; Buller, P.; Gil, R.J.; Bil, J. 48-Month Clinical Outcomes and Prognostic Factors in an All-Comers Population with Acute Coronary Syndrome and Chronic Coronary Syndrome Undergoing Percutaneous Coronary Intervention with a Sirolimus-Eluting Stent. J. Pers. Med. 2023, 13, 1573. https://doi.org/10.3390/jpm13111573

AMA Style

Tyczynski M, Kern A, Buller P, Gil RJ, Bil J. 48-Month Clinical Outcomes and Prognostic Factors in an All-Comers Population with Acute Coronary Syndrome and Chronic Coronary Syndrome Undergoing Percutaneous Coronary Intervention with a Sirolimus-Eluting Stent. Journal of Personalized Medicine. 2023; 13(11):1573. https://doi.org/10.3390/jpm13111573

Chicago/Turabian Style

Tyczynski, Maciej, Adam Kern, Patryk Buller, Robert J. Gil, and Jacek Bil. 2023. "48-Month Clinical Outcomes and Prognostic Factors in an All-Comers Population with Acute Coronary Syndrome and Chronic Coronary Syndrome Undergoing Percutaneous Coronary Intervention with a Sirolimus-Eluting Stent" Journal of Personalized Medicine 13, no. 11: 1573. https://doi.org/10.3390/jpm13111573

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop