Next Article in Journal
An Elaboration on Sample Size Planning for Performing a One-Sample Sensitivity and Specificity Analysis by Basing on Calculations on a Specified 95% Confidence Interval Width
Next Article in Special Issue
Multiparametric Skin Assessment in a Monocentric Cohort of Systemic Sclerosis Patients: Is There a Role for Ultra-High Frequency Ultrasound?
Previous Article in Journal
Automatic Classification of GI Organs in Wireless Capsule Endoscopy Using a No-Code Platform-Based Deep Learning Model
Previous Article in Special Issue
Quantitative Ultrasound Techniques Used for Peripheral Nerve Assessment
 
 
Article
Peer-Review Record

Ultra-High Frequency Ultrasound Imaging of Bowel Wall in Hirschsprung’s Disease—Correlation and Agreement Analyses of Histoanatomy

Diagnostics 2023, 13(8), 1388; https://doi.org/10.3390/diagnostics13081388
by Tebin Hawez 1, Christina Graneli 1, Tobias Erlöv 2, Emilia Gottberg 3, Rodrigo Munoz Mitev 3, Kristine Hagelsteen 1, Maria Evertsson 4, Tomas Jansson 4, Magnus Cinthio 2 and Pernilla Stenström 1,*
Reviewer 1:
Reviewer 2: Anonymous
Diagnostics 2023, 13(8), 1388; https://doi.org/10.3390/diagnostics13081388
Submission received: 9 February 2023 / Revised: 2 April 2023 / Accepted: 4 April 2023 / Published: 11 April 2023

Round 1

Reviewer 1 Report

Dear Authors

This is an interesting paper.

I would like the Authors to highlight the learning curve needed to be confident in diagnosing HD with US. It would be also interesting to see if a multicentre study is potentially needed. This is an important point as could help many colleagues that don't have pathologists on site.

It is important to have long terms outcomes in a follow-up paper.

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 2 Report

The manuscript addresses the relevant issue of bowel wall evaluation in Hirschsprung’s disease. There are few minor issues requiring authors' attention:

- UHFUS imaging section should report the acquisition protocol employed, including technical parameters (gain, TGC, etc..)

- Please report how calibration between the two paediatric surgeons was performed (prior to study beginning on samples not included in the study?), and the Cohen kappa value.

- Please specify how the ROI was selected on UHFUS images.

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Back to TopTop