Next Article in Journal
KCTD15 Is Overexpressed in her2+ Positive Breast Cancer Patients and Its Silencing Attenuates Proliferation in SKBR3 CELL LINE
Next Article in Special Issue
Use of U-Net Convolutional Neural Networks for Automated Segmentation of Fecal Material for Objective Evaluation of Bowel Preparation Quality in Colonoscopy
Previous Article in Journal
Open-Source, Adaptable, All-in-One Smartphone-Based System for Quantitative Analysis of Point-of-Care Diagnostics
Previous Article in Special Issue
Machine Learning Model for Outcome Prediction of Patients Suffering from Acute Diverticulitis Arriving at the Emergency Department—A Proof of Concept Study
 
 
Article
Peer-Review Record

Accuracy and Efficiency of Right-Lobe Graft Weight Estimation Using Deep-Learning-Assisted CT Volumetry for Living-Donor Liver Transplantation

Diagnostics 2022, 12(3), 590; https://doi.org/10.3390/diagnostics12030590
by Rohee Park 1, Seungsoo Lee 1,*, Yusub Sung 2, Jeeseok Yoon 3, Heung-Il Suk 3,4, Hyoungjung Kim 1 and Sanghyun Choi 1
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Diagnostics 2022, 12(3), 590; https://doi.org/10.3390/diagnostics12030590
Submission received: 26 January 2022 / Revised: 21 February 2022 / Accepted: 23 February 2022 / Published: 25 February 2022

Round 1

Reviewer 1 Report

Authors, through a retrospective study, aims at deriving a graft volume-to-weight conversion formula and to evaluate the accuracy and time efficiency of deep learning segmentation -assisted CT volumetry for estimating graft weight in a large cohort of living liver donors who donated right-lobe liver grafts.

The chosen DL approach is the GOCDSS by SmartCareWorks. 

The choise of using a specific commercial deepl learning based liver segmentation tool, limits too much the conclusions in assessing the efficacy of using DL to estimate the liver weight.

Some minor changes are needed:

  • Sec 2.2: add the total number of images for each patient and slice thickness
  • sec 3.3 the weight range is from 767.8 ml to 1880.7 ml that doesn't correspond to the values reported in Fig. 3

Author Response

Point by point responses to reviewers’ comments

 

Reviewer #1

R1-1 Sec 2.2: add the total number of images for each patient and slice thickness

  • We added total number of images according to slice thickness.

R1-2 sec 3.3 the weight range is from 767.8 ml to 1880.7 ml that doesn't correspond to the values reported in Fig. 3

  • We appreciate the reviewer for indicating our mistake. We have corrected the text.

Reviewer 2 Report

The paper entitled  “Accuracy and efficiency of right-lobe graft weight estimation using deep learning-assisted CT volumetry for living donor liver transplantation” by. Rohee Park et al. evaluates the efficiency and accuracy of deep learning algorithm and CT volumetry in pre-operative graft weight.
In section 2.1. Study population it is mentioned that the validation group is 374 patients form 581, however, it is over 60% from the target group, it is unclear why the authors have chosen so a large group for validation. 
In the section „2.2. CT examination” is shown the acquisition stage, the authors should add the quality and resolution of the images. 
In the section „2.3. Graft volume measurement using a deep learning algorithm” is added the processed image with the proposed algorithm, please add a pseudocode or logic scheme of it. 
In the section „2.5. Statistical analysis” the Bland–Altman is a statistical method for analyzing the agreements between the whole liver volume automatically measured by DLA and those measured after the radiologist’s correction. The paper should be described the method of how was computed the volume. 
The quality of Figures 3, 4, and 5 should be improved.
The results are compared with studies from 2010 (reference 8) 2003 (reference 12) however these are old taking into account that the study is based on a deep learning algorithm. 
Please create a separate conclusion section. 

Author Response

Point by point responses to reviewers’ comments

 

Reviewer #2

R2-1 In section 2.1. Study population it is mentioned that the validation group is 374 patients form 581, however, it is over 60% from the target group, it is unclear why the authors have chosen so a large group for validation. 

  • It is a usual approach to have a larger development group than the validation group. However, we decided to have a larger validation group than the development in our study because of the following reasons: first, we considered that the 207 donors would be sufficient for constructing volume to weight conversion equation. Second, the main purpose of our study was to evaluate the measurement error in graft weight estimation using CT volumetry, which, we considered, need to be evaluated in a large validation group for a precise estimation.

 

R2-2 In the section „2.2. CT examination” is shown the acquisition stage, the authors should add the quality and resolution of the images

  • According to the reviewer’s suggestion, we provided the resolution (matrix of 512 x 512) of CT images. However, we do not understand what the reviewer exactly means by the quality of CT examination. As we already mentioned in section 2.2 and supplementary table 1, CT examinations were conducted using up-to-date scanner system and standard technique and thus considered to be performed with clinically acceptable image quality.

R2-3 In the section „2.3. Graft volume measurement using a deep learning algorithm” is added the processed image with the proposed algorithm, please add a pseudocode or logic scheme of it. 

  • We provided source code for the deep learning algorithm

R2-4 In the section „2.5. Statistical analysis” the Bland–Altman is a statistical method for analyzing the agreements between the whole liver volume automatically measured by DLA and those measured after the radiologist’s correction. The paper should be described the method of how was computed the volume. 

  • We already stated that liver volume was calculated by summation of the area multiplied by the slice interval. According to the reviewer’s recommendation, we additionally stated that the liver volumes measured by automated segmentation by the deep learning algorithm and those measured after the reader’s correction were recorded.

R2-5 The quality of Figures 3, 4, and 5 should be improved.

  • According to the reviewer’s suggestion, we have improved the quality of figures

R2-6 The results are compared with studies from 2010 (reference 8) 2003 (reference 12) however these are old taking into account that the study is based on a deep learning algorithm.

  • We appreciate the reviewer for the constructive criticism on our study. We tried to find up-to-date references to be compared with our results. However, as we already stated in our manuscript, there was no recent publication on this topic. We speculate that this reflects a lack of advance in CT volumetry until the emergence of deep learning-based algorithm for automated organ segmentation, which highlights the importance of our findings.

R2-7. Please create a separate conclusion section. 

  • We created a separate conclusion section according to the reviewer’s suggestion.

 