Next Article in Journal
A Critical Review on Engineering of d-Mannitol Crystals: Properties, Applications, and Polymorphic Control
Next Article in Special Issue
Preparation of Large Volume Solid Argon Crystal and Its Feasibility Test as a Scintillation Material
Previous Article in Journal
Structural and Antimicrobial Characterization of Co-Crystal [Ni(bpy)(acr)2(H2O)]·MA
Previous Article in Special Issue
Fabricating High-Conduction and High-Transparency Tungsten-Doped Zinc Oxide Films by Pulse Laser Deposition Technique
 
 
Article
Peer-Review Record

Low-Frequency Vibration Sensor with Dual-Fiber Fabry–Perot Interferometer Using a Low-Coherence LED

Crystals 2022, 12(8), 1079; https://doi.org/10.3390/cryst12081079
by Mu-Chun Wang 1,*, Shou-Yen Chao 1, Chun-Yeon Lin 2,*, Cheng-Hsun-Tony Chang 1 and Wen-How Lan 3
Reviewer 1:
Reviewer 2: Anonymous
Crystals 2022, 12(8), 1079; https://doi.org/10.3390/cryst12081079
Submission received: 6 July 2022 / Revised: 22 July 2022 / Accepted: 23 July 2022 / Published: 1 August 2022
(This article belongs to the Special Issue Optoelectronics and Photonics in Crystals)

Round 1

Reviewer 1 Report


Comments for author File: Comments.pdf

Author Response

Please see the attached file. Thanks a lot.

Author Response File: Author Response.pdf

Reviewer 2 Report

Manuscript No:  crystals-1827996

Title:  Low-Frequency Vibration Sensor with Dual Fiber Fabry-Perot Interferometer Using a Low-Coherence LED Light Source

 

Authors:  Mu-Chun Wang, Shou-Yen Chao, Chun-Yeon Lin, Cheng-Hsun-Tony Chang and Wen-How Lan

 

A. Overview

1. In this manuscript the authors report on a Fabry–Perot interferometer for vibration sensing made off with a dual fiber and a low-coherence led light source.

2. The contents are expressed clearly.

3. The manuscript is well organized,

4. It is written in reasonable English.

5. The authors have acknowledged recent related research.

6. As long as my knowledge, the work presented is original.

7. Several typos along de manuscript, authors must have a second read

 

B. Detailed analysis.

 

Abstract is not clear enough.

-Please organize the ideas in each paragraph.

-Be clear, objective.

-State briefly what you did, how did you do it, the quantitative results you and

-State clearly the novelty of your work.

 

1. Introduction: provides an interesting approach to the subject and there are up to date references.

2. Sensing Principles of a Dual FFPI and Experimental Setup: provides the basic principles of Fabry-Perot interferometry – this can be shortened as it is well known.

There are too many figures in the manuscript which is unfavorable to reading.

For instance, figures 3 b and can be deleted.

Figure 4 is standard measurement technique, it can be withdrawn.

Figure 5 is LED characterization – not relevant to communicate new result to readers.

It is interesting that authors did a temperature characterization, but figure 6 is not needed – no new information.

 

C. Overall assessment

The work here presented is interesting. However it is too lengthy and too much information is presented, of which much is unnecessary. In my opinion the work cannot be published as is and must be re-written.

 

D. Review Criteria

1. Scope of Journal

Rating: Low

2. Novelty and Impact

Rating: Low

3. Technical Content

Rating: Low

4. Presentation Quality

Rating: Low

Author Response

Please see the attached file. Many thanks.

Author Response File: Author Response.pdf

Round 2

Reviewer 1 Report

The revision has addressed all my concerns. I think the current version can be accepted for publication.

Reviewer 2 Report

The authors introduced corrections to the manuscript

and improved it. As well they answered

to the questions and queries of the reviewers.

In my opinion the ms can be published.

Back to TopTop