Next Article in Journal
Hydrogen Production Improvement on Water Decomposition Through Internal Interfacial Charge Transfer in M3(PO4)2-M2P2O7 Mixed-Phase Catalyst (M = Co, Ni, and Cu)
Next Article in Special Issue
Acceleration of Persulfate Activation by MIL-101(Fe) with Vacuum Thermal Activation: Effect of FeII/FeIII Mixed-Valence Center
Previous Article in Journal
Kinetic Resolution of Racemic Amines to Enantiopure (S)-amines by a Biocatalytic Cascade Employing Amine Dehydrogenase and Alanine Dehydrogenase
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Activated Carbon as a Cathode for Water Disinfection through the Electro-Fenton Process

Department of Civil and Environmental Engineering, Northeastern University, Boston, MA 02115, USA
*
Author to whom correspondence should be addressed.
Catalysts 2019, 9(7), 601; https://doi.org/10.3390/catal9070601
Submission received: 20 June 2019 / Revised: 8 July 2019 / Accepted: 10 July 2019 / Published: 12 July 2019
(This article belongs to the Special Issue Environmental Catalysis in Advanced Oxidation Processes)

Abstract

:
Unlike many other water disinfection methods, hydroxyl radicals (HO) produced by the Fenton reaction (Fe2+/H2O2) can inactivate pathogens regardless of taxonomic identity of genetic potential and do not generate halogenated disinfection by-products. Hydrogen peroxide (H2O2) required for the process is typically electrogenerated using various carbonaceous materials as cathodes. However, high costs and necessary modifications to the cathodes still present a challenge to large-scale implementation. In this work, we use granular activated carbon (GAC) as a cathode to generate H2O2 for water disinfection through the electro-Fenton process. GAC is a low-cost amorphous carbon with abundant oxygen- and carbon-containing groups that are favored for oxygen reduction into H2O2. Results indicate that H2O2 production at the GAC cathode is higher with more GAC, lower pH, and smaller reactor volume. Through the addition of iron ions, the electrogenerated H2O2 is transformed into HO that efficiently inactivated model pathogen (Escherichia coli) under various water chemistry conditions. Chick–Watson modeling results further showed the strong lethality of produced HO from the electro-Fenton process. This inactivation coupled with high H2O2 yield, excellent reusability, and relatively low cost of GAC proves that GAC is a promising cathodic material for large-scale water disinfection.

Graphical Abstract

1. Introduction

The burden of waterborne pathogens is significant and can lead to severe health complications [1,2]. To minimize the likelihood of contamination, drinking water is typically treated using a multi-barrier approach including disinfection and maintenance of a disinfectant residual during distribution of drinking water to the consumers. Most commonly used disinfection methods include ozonation, chlorination, chloramination, UV irradiation, and their combinations [3,4,5]. While each of these methods can be effective, they have key limitations. For instance, the electrochemical production of ozone relies on high voltage [6,7], and storage and transport of gaseous ozone is risky due to its high reactivity, thus it is usually produced onsite. Chlorination can result in formation of carcinogenic disinfection byproducts (DBP) [8], which may require pre-chlorination approaches to minimize DBP formation and additional significant efforts to manage post-chlorination DBP concentrations [9]. UV irradiation kills microorganisms by damaging double-stranded DNA [10,11], but this strategy is ineffective in turbid conditions; moreover, cells might reverse the DNA damage through a repair mechanism [12,13,14].
Hydroxyl radicals generated from H2O2 decomposition are effective in inactivating varying cell types, such as bacteria, eukaryotes, and viruses [15,16]. HO inactivates microbes primarily through the destruction of vital cellular components, including surface proteins, NAD(P)H, and DNA [17]. Post HO exposure, bacteria usually exhibit ruptured morphology [18], which indicates cell surface damage and osmotic shock due to leakage of cellular components. The severe destruction of cell structure is the most plausible reason for strong disinfection potential of HO. Despite its effectiveness, the most significant challenge with the large-scale application of the Fenton process is the prohibitive cost of hydrogen peroxide (H2O2) (~USD $1.5/kg for bulk purchase) [19].
Recently, electrogeneration of H2O2 via two-electron reduction of oxygen has drawn considerable interest. With specific cathodes, dissolved oxygen accepts two electrons and converts to H2O2 through an oxygen reduction reaction [Equation (1)] [20,21]. Many types of carbon materials, such as reticulated vitreous carbon foam, graphite felt, carbon felt, and carbon nanotubes, have been used as cathodes [22]. Previous reports suggest that oxygen- and nitrogen-containing functional groups on the surface are particularly beneficial for electron transfer to oxygen [23]. Therefore, a large number of modification methods (e.g., acid/base incubation, pyrolysis of coated resins, etc.) to the abovementioned carbonaceous materials are being tested to enhance H2O2 titer [24,25]. However, these costly modifications are not ideally suitable for large-scale applications.
O 2 + 2 H + + 2 e H 2 O 2   ( 0.695   V   vs .   SHE ,   standard   hydrogen   electrode )
Granular activated carbon (GAC) has long been used as an adsorbent to remove environmental contaminants [26]. It has been reported that electrochemical polarization, which creates an anode on one side and a cathode on the other side, could regenerate GAC adsorbent beds after saturated adsorption of organic contaminants [27,28]. During this process, H2O2 is generated on the cathode side, indicating that GAC has two-electron electrochemical oxygen reduction activity [28]. To date, studies using an entire GAC as a specific cathode to electrogenerate H2O2 are relatively lacking. Further, GAC is likely the cheapest functional carbon material, adding further viability towards its large-scale implementation in the future. In this study, we aim to evaluate the feasibility of using pristine GAC for water disinfection with Escherichia coli as a model pathogen. Electrogeneration of H2O2 was measured under various conditions, and HO from the reaction between iron ion and H2O2 was then used to inactivate E. coli. The development of the GAC-based electro-Fenton process for water disinfection is especially desirable in low-income regions and could meet the needs of their sustainable development. Besides, the novel application of amorphous GAC as a cathode has great implication in that other amorphous carbon materials (such as biochar manufactured from biomass precursor) could also be used for hydrogen peroxide generation. It is overall anticipated that this study could advance the application of low-cost carbons for electrochemical water treatment purpose.

2. Results and Discussion

2.1. Generation of Hydrogen Peroxide with GAC Cathode

The used GAC had a specific surface area of 840.5 m2/g, providing sufficient catalytic sites for H2O2 generation. Carbon- (C1s) and oxygen-containing (O1s) groups are abundant on the GAC surface [28] and increased the hydrophilicity and mediated the facile generation of H2O2 [23]. Typically, functional groups such as carboxyl and etheric groups are particularly favored for oxygen reduction into H2O2 [29]. We fabricated the cathode by loading a certain amount of GAC into a stainless-steel mesh. This hybrid cathode was tightly wrapped by a rubber band to ensure sufficient contact between the stainless-steel mesh and the conductive surface of GAC (Figure S1 of Supplementary Material). A Ti/MMO mesh anode was used to produce oxygen instead of air ventilation for H2O2 generation. The mechanism for H2O2 generation was initially explored in our previous work [28]. The GAC cathode produced a significant amount of H2O2 in the rage of 3–20 mg/L after 60 min (Table 1). This is particularly important, because other functional, higher priced carbonaceous materials typically produce 12–36 mg/L H2O2 in similar settings [30,31,32].

2.2. Parameters that Influenced H2O2 Yield

We tested various parameters that influenced the H2O2 yield (Table 1). Increasing GAC mass from 1 to 3 g in 200 mL solution increased H2O2 yield from 4.12 to 14.64 mg/L. The improved yield of H2O2 was primarily due to the increase in reactive sites with increasing GAC mass per electrolyte volume. Moreover, the electrogeneration of H2O2 by GAC cathode was more effective under acidic pH, as a higher concentration of protons could mediate a faster reaction rate. When the pH was reduced from 5 to 3, the H2O2 yield increased by 36.6% from 14.90 to 20.36 mg/L. However, the change of pH from 11 to 5 did not result in such drastic change in H2O2 production (i.e., 12.74 to 14.90 mg/L), because low proton concentration under this pH range limited H2O2 formation. We further tested H2O2 yield at different currents, while other parameters were fixed (3 g GAC, 200 mL volume, pHini 7). Increasing current from 50 to 100 mA increased H2O2 yield from 3.38 to 14.64 mg/L. Further increase in the current to 150 mA decreased H2O2 yield to 10.7 mg/L. This was presumably because of the parasitic H2O2 decomposition on the anode [28]. We assessed the effect of reactor volume, which is important for large-scale application in practice. Reaction conditions were 3 g GAC, 100 mA current, and pHini 7. Results showed that increasing reactor volume from 200 to 400 mL decreased the H2O2 yield from 14.64 to 10.69 mg/L. The current efficiency, however, increased from 4.62% to 6.74%, indicating a higher accumulated H2O2 amount, primarily because the consumption pathway of H2O2 was weakened at low H2O2 concentration. These results suggest that larger reactor volume mediates greater utilization efficiency of the electrons.
The electrogeneration of H2O2 tended to acidify the solution, which was desirable for the Fenton reaction. This was because, during the electrogeneration of H2O2, the proton generation exceeded hydroxyl ion generation. As a result, solution pH was between 2.8 and 4.2 in assays after 60 min reaction (Table 1), and such acidity was suitable for the subsequent Fenton reaction.
It is important to note that the ability of GAC to generate H2O2 is feasible under various granularities. We tested GAC of varying sizes (i.e., 4–8 mesh, 4–12 mesh, 4–14 mesh, and 5 mm) and found that they consistently produced H2O2 with a yield of 11–16 mg/L, exhibiting approximately similar oxygen reduction activities. This was likely because oxygen reduction to H2O2 occurred on the catalytic sites on both internal pores and the external surface, and the GAC granularity thus did not affect the total number of catalytic sites. This indicated that the electrogeneration of H2O2 could occur on a variety of GAC types, suggesting the practical applicability of this method.

2.3. Disinfection of E. coli through Electro-Fenton Process

In this study, electrogenerated H2O2 was used for water disinfection of E. coli as a model pathogen. The disinfection efficiency of H2O2 alone is relatively low, because the genetically encoded catalases can efficiently decompose H2O2 into water and oxygen [33]. In contrast, HO from the Fenton reaction could effectively kill a wide variety of microorganisms regardless of their cellular structure or genetic potential [15,16].
Electrogenerated H2O2 was transformed into highly oxidizing HO in the presence of ferrous iron ions. The process of electrogeneration of H2O2 from the GAC cathode and transformation into HO by iron ions is known as the electro-Fenton process. The HO yield was measured with the benzoic acid quantification method [34]. Iron ions concentrations of 0.05, 0.2, and 0.4 mM resulted in the production of 125.9, 224.53, and 241.8 µM HO after 60 min of the electro-Fenton process, respectively (Figure 1a), with no significant difference in HO generated between 0.2 mM and 0.4 mM concentrations. Moreover, the GAC cathode at 100 mA mediated the highest HO yield compared with other electric currents (Figure 1b), indicating that there is an optimum value for the current.

2.3.1. Mechanism of Electro-Fenton Disinfection

Treatment by either GAC cathode or ferrous ions alone mediated 1.15- and 0.53-log reduction in cell viability, respectively. The electro-Fenton process coupling both GAC cathode and ferrous ions led to a 2.40-log inactivation of E. coli cells, as the generated HO was a strong bactericide (Figure 2a,b). The GAC cathode under 100 mA inactivated E. coli mainly via the combination of generated H2O2 and acidification (pH decreased to 3.45, Table 1), whereas H2O2 at 2 mM or acid pH of 3 individually led to less than 0.46-log of bacterial inactivation (Figure S3 of Supplementary Material). H2O2 slightly inactivated bacteria, likely through the oxidation of sulfhydryl groups of functional enzymes [35]. Acidic pH denatured the protein structure and may also have increased the permeability of the cell membrane [36]. In addition, ferrous ions were slightly bactericidal after oxidation into ferric ions (Fe3+), which could have denatured the functional enzymes through the oxidation of side chains of amino acids [37].
Nonetheless, HO likely played a major role in E. coli inactivation. Addition of 50 mM MOPS buffer (3-(N-morpholino)propanesulfonic acid) to attenuate solution acidification of the electro-Fenton process (Figure 3a) decreased H2O2 yield from 14.64 to 4.13 mg/L, using the GAC as a cathode after a 60 min reaction. Consistently, HO yield was also reduced from 224.53 to 64.15 µM in the electro-Fenton process. Furthermore, the addition of 50 mM MOPS buffer to the electro-Fenton process resulted in 0.53-log E. coli cell inactivation due to reduced HO production (Figure 3c), which was significantly less than the electro-Fenton disinfection without the buffer (i.e., 2.40-log). The use of 50 mM thiourea to quench H2O2 and HO (Figure 3b) resulted in negligible concentrations of H2O2 or HO during the course of the electro-Fenton reactions, and concomitant decrease in the inactivation of E. coli cells (1.11-log) was observed after 60 min (Figure 3c). Taking these results together, we concluded that the disinfection of E. coli by the electro-Fenton process was primarily due to the HO from electrogenerated H2O2 under activation of ferrous ions in an acidic pH.

2.3.2. Complete Disinfection of E. coli of Various Concentrations

Continuous monitoring of H2O2 and HO yields over 300 min (Figure 4a) revealed that H2O2 generation was rapid during the first 40 min then slowed down. H2O2 concentration reached a plateau of 16.74 mg/L at 100 min. The measured H2O2 concentration was the total H2O2 generation minus H2O2 decomposition [Equation (10)]. Total electrogeneration rate of H2O2 was determined by applied electric potential and dissolved oxygen content, while H2O2 decomposition was largely affected by H2O2 concentration. Therefore, as the H2O2 concentration in bulk solution increased, its decomposition rate increased due to the more prominent parasitic pathways [Equations (3)–(6)]. When the H2O2 generation rate was equal to the decomposition rate, an equilibrium concentration (plateau) was reached in agreement with electrogeneration of H2O2 on other cathodes [30,32].
[ H 2 O 2 ] m e a s u r e d = 0 t r [ H 2 O 2 ] g e n e r a t i o n d t 0 t r [ H 2 O 2 ] d e c o m p o s i t i o n d t
Parasitic H2O2 decomposition pathways:
H 2 O 2 + 2 H + + 2 e 2 H 2 O
H 2 O 2 H O 2 + H + + e
H O 2 O 2 + H + + e
2 H 2 O 2 H 2 O + O 2
We added 0.2 mM ferrous ions into the solution to transform H2O2 into HO. The generated Fe3+ after the reaction could then be reduced into Fe2+ on the cathode and again used for H2O2 activation. Hence, the HO was constantly generated in the presence of both the GAC cathode and the iron ion, as quantified via the addition of benzoic acid (Figure 4a). The HO yield at 100 min was 279.61 µM and reached 379.84 µM after 300 min.
The disinfection of E. coli at 104, 106, and 108 CFU/mL was tested respectively over 300 min (Figure 4b). The electro-Fenton process could completely remove 104 CFU/mL E. coli within 60 min, and 5.02-log E. coli removal was achieved after 180 min at an initial concentration of 106 CFU/mL. The process also inactivated 6.1-log E. coli after 300 min with an initial concentration of 108 CFU/mL. The results indicate that GAC as a cathode could efficiently inactivate E. coli at varying concentrations.

2.3.3. Chick–Watson Model

E. coli inactivation kinetics was fitted with the first-order Chick–Watson model. CT values (disinfectant concentration × contact time) for electric current, H2O2, and HO as input disinfectant were individually plotted against decimal logarithm of bacterial survival rate [i.e., ln(N/N0)] (Figure 5). The Chick–Watson coefficients (ΛCW) for electric current, H2O2, and HO were determined to be 0.248 A−1 min−1, 1.63 × 10−3 mg−1 L min−1, and 6.52 × 105 mg−1 L min−1, respectively. Chick–Watson model fitting with HO as disinfectant showed the highest correlation coefficient (R2 = 0.984) compared with fitting results of electric current (R2 = 0.903) and H2O2 (R2 = 0.843), presumably because HO is the species directly responsible for E. coli inactivation. Interestingly, the ΛCW of HO in this study was 3.9 times greater than the reported value under neutral conditions (1.33 × 105 mg−1 L min−1) [38], possibly because other parameters such as acidic conditions synergistically enhanced the bactericidal role of HO. Moreover, the lethality of HO (2.70 V) was several orders higher than ozone (50 mg−1 L min−1, 2.07 V), chlorine (15.4 mg−1 L min−1, 1.36 V), or chlorine dioxide (25 mg−1 L min−1, 1.91 V), primarily due to its strong oxidation potential [38].

2.4. Resistance to Water Alkalinity

The generation of HO radical bactericide from the Fenton reaction relies on an acidic pH. However, most natural water bodies can maintain buffering capacity, which is called water alkalinity, because of carbonate ions from atmospheric carbon dioxide or sediment rock mineral. The typical alkalinity of waters is below 200 mg CaCO3/L [39,40]. Thus, large amounts of acid are necessary to overcome such high alkalinity, or the efficiency of the traditional Fenton process for water treatment would be severely compromised. Given that produced protons on the anode exceed released hydroxyl ions on the cathode, the electro-generation of H2O2 led to an automatic acidification of the solution, which facilitated the Fenton reaction. However, little is known about solution acidification by the electrogeneration of H2O2 in carbonated media.
The effectiveness of the electro-Fenton process toward E. coli disinfection was therefore tested under two representative alkalinity conditions. It was observed that electrogeneration of H2O2 tended to acidify the solution regardless of carbonate concentration, and solution pH decreased to 3.45 in the presence of 2 mM carbonate after 60 min. Moreover, the presence of 1–2 mM carbonate ion exhibited negligible impact on H2O2 generation (Figure 6). Specifically, the electrogenerated H2O2 yields were 14.64, 13.31, and 13.91 mg/L by GAC cathode with 0, 1, and 2 mM carbonate, respectively. As a result, the disinfection efficiency by the electro-Fenton process was not affected by the presence of carbonate ions. This further highlights the practicality of the electro-Fenton process for water disinfection under buffered conditions.

2.5. Reusability of GAC Cathode

The active sites on the GAC surface are under cathodic potential during the electro-Fenton process. This could result in the reductive elimination of functional groups of certain carbonaceous materials, and the potency to produce H2O2 might drastically decrease [30]. GAC is known to harbor abundant functional groups that exist both on the external surface and the internal pore surface [41]. Thus, it is important to assess the effect of long-term cathodic current-mediated oxygen reduction on the catalytic activity of GAC.
We tested the durability of the GAC cathode for multiple rounds of application for water disinfection. After each round of the electro-Fenton reaction, the GAC was extensively washed with diluted sulfuric acid and then rinsed with Milli-Q water. The cleaned and oven-dried GAC was then applied to the next round of the electro-Fenton reaction. The H2O2 yields were sustained between 11.34 and 14.64 mg/L without notable decrease for a minimum of five rounds of application and regeneration (Figure 7a). Moreover, with the addition of ferrous ions, the stable H2O2 generation consistently led to 2.26–2.60 log reduction of E. coli in each round due to the production of HO radicals (Figure 7b).

2.6. Disinfection of E. coli with Antibiotic-Resistance Genes

Bacteria hosting antibiotic-resistance genes (ARGs) have been an emerging concern in water treatment, and they are resistant to common antibiotic drugs due to inherent efflux pumps [42]. In addition, ARGs of a bacterial species could be relayed to another bacterial species through horizontal gene transfer [43]. Previous research reported that, among all the water disinfection technologies, only advanced oxidation processes generating oxidative radicals (such as HO) could potently damage ARGs and effectively prevent horizontal gene transfer [44].
Electrogeneration of H2O2 with the GAC cathode is a practical method and is affordable by most water treatment plants. We utilized the electro-Fenton process to disinfect E. coli with various ARGs. Antibiotic-resistant E. coli cells were obtained after transferring plasmids encoding corresponding ARGs into competent cells followed by antibiotic selection on a Luria-Bertani (LB)-agar plate. Results indicated that the electro-Fenton process could non-selectively inactivate E. coli with different ARGs (e.g., ampicillin-, kanamycin-, tetracyclin-, chloramphenicol-, zeocin-, and spectinomycin-resistance genes). For instance, 2.18–2.41 log of E. coli cells were reduced after 1 h treatment (Figure S4 of Supplementary Material). Additionally, the complete disinfections of E. coli cells were obtained after 300 min (Figure 8) regardless of the hosted ARGs, highlighting the great promise of the process. However, this was not surprising, because HO disinfection mainly occurs through destruction of cellular structure and is not related to genetic potential.

2.7. Techno-Economic Analysis

GAC as a porous carbon material has long been used as an adsorbent for the removal of water contaminants. Owing to the various functional groups on the surface, the GAC cathode is reported to mediate hydrogen peroxide formation via an oxygen reduction reaction. An important advantage of the GAC cathode is the relatively low cost. The market price of GAC is around USD $0.75 per kilogram in a large-scale purchase [45]. Moreover, GAC can be reused for multiple rounds without loss of catalytic activity, further lowering the operation cost. GAC can also be produced from the pyrolysis of biomass, such as coconut shell [46] or other waste materials [47]. The utilization of waste biomass to generate H2O2 for water treatment is especially attractive, considering that both water treatment and biomass treatment consume large amounts of cost and energy. The application of GAC as a cathode for water disinfection is thereby promising.
Unlike traditional water treatments, which rely on a single dose of a high concentration of oxidants, the electro-Fenton process continuously generates a low concentration of H2O2. The low concentration of H2O2 is instantly converted into HO in the presence of ferrous ions. In fact, the continuous and mild generation of oxidants is more favored than the single dose of high concentration of oxidants in practice, because the former method holds great promise to address the contaminants rebound phenomena [48,49]. Besides the contaminants rebound, residual water pathogens after a single treatment can also proliferate with a supply of nutrients. The developed electro-Fenton process is anticipated to completely eliminate water pathogens with continuous generation of H2O2.

3. Materials and Methods

3.1. Materials

Granular activated carbon (GAC, 4–8 mesh) as a cathode for oxygen reduction was obtained from Calgon Carbon Corporation. GACs of other sizes, i.e., 4–12 mesh, 4–14 mesh, and < 5 mm, were obtained from Calgon Carbon Corporation as well. Sodium sulfate (Na2SO4, ≥99%), titanium sulfate (TiSO4, 99.9%), ferrous sulfate (FeSO4), hydrogen peroxide (30% wt.), sodium carbonate (Na2CO3), and benzoic acid (C7H6O2, >99%) were purchased from Fisher Scientific (Hampon, NH, USA). MOPS buffer (C7H15NO4S) was purchased from Corning Inc. (Corning, NY, USA). Thiourea (CH4N2S, >99%) as a quencher of H2O2 and HO was purchased from ACROS Organics Inc. Luria-Bertani (LB) broth and agar for E. coli enumeration were purchased from BD, Difco Inc. Meshed Ti/mixed metal oxide (Ti/MMO, 3N International) was used as anode material.

3.2. Characterizations of Granular Activated Carbon

Nitrogen adsorption/desorption isotherm of the employed GAC was measured at −196 °C (ASAP 2420 V2.05). Then, the Brunauere–Emmete–Teller (BET) specific surface area was calculated from the isotherm curve. The volumes of micropore and mesopore were estimated using the Horvath–Kawazoe method and the Barrett–Joynerand–Halenda method, respectively. The pore size distribution was determined using the nonlocal density functional theory by the adsorption branch, and the total pore volume was calculated from the nitrogen amount adsorbed at a relative pressure of 0.975. Results showed that the GAC was microporous with an average pore width of less than 1 nm, and the specific surface area was 840.5 m2/g.

3.3. Batch Experiments for Disinfection

Before the experiments, 10 g GAC was pre-treated by vigorously stirring in 300 mL Milli-Q water with a magnetic bar for 10 min. The eluent was discarded, and GAC pellets were re-washed with 300 mL Milli-Q water. The washing steps were repeated until the eluent was clear. The GAC particles were then dried at 80 °C for 2–3 h. Log growth phase E. coli culture [200 mL, 108 CFU/mL (CFU, colony forming unit)] was used for electro-Fenton disinfection experiments. Specifically, a single colony of E. coli K12 from an LB-agar plate was seeded in LB nutrient broth and cultured at 37 °C overnight. Then, 1% of the fully-grown bacteria solution was diluted in a sterile flask containing fresh LB medium and cultured for around 2 h until the log phase (OD600 ~ 0.8–1). Bacteria were harvested by centrifuging the E. coli culture at 10,000 g for 10 min, followed by intensive washing with Milli-Q water. The centrifugation and the washing steps were repeated three times, and the washed E. coli culture was used for experiments. During the electro-Fenton process, 3 g GAC held in a stainless-steel mesh was used as a cathode under 100 mA current with 10 mM Na2SO4 electrolyte and 0.2 mM FeSO4 as the catalyst. A schematic configuration of the reactor is shown in Figure S1 of Supplementary Material. Every 20 min, the bacterial solution was withdrawn for subsequent quantification.

3.4. E. coli Quantification Method

E. coli was quantified through a serial dilution method as reported previously [50,51,52]. Briefly, the sampled E. coli solution was put in the first row of a sterilized 96-well plate. The ten-fold serial dilution was performed by taking 20 µL well-mixed bacterial solution into the next row containing 180 µL phosphate buffered saline (PBS) physiological buffer. A total of 5 µL liquid from the serial dilution wells was plated on the LB-agar plate and incubated at 37 °C overnight. The survival rate was calculated from the CFU after treatment divided by that before treatment [Equation (7)].
Survival   rate = bacteria   after   treatment   ( CFU / mL ) bacteria   before   treatment   ( CFU / mL ) × log 10 10

3.5. Hydrogen Peroxide and Hydroxyl Radical Quantification Method

The generated H2O2 using the GAC cathode without iron ions was quantified by complexing with titanium sulfate [53]. The absorbance of the developed yellow color was measured with a UV-Vis spectrometer at 405 nm. H2O2 generation was quantified under various conditions, e.g., GAC amount, solution pH, reactor volume, GAC granularity, and current intensity. During the electro-Fenton process, HO was generated from the Fenton (Fe2+/H2O2) reaction using the GAC cathode in the presence of iron ions and quantified using benzoic acid. Three grams of GAC hosted by stainless-steel mesh were transferred into a 200 mL solution of 10 mM Na2SO4 and 10 mM benzoic acid at pH 7 overnight under constant stirring. Benzoic acid saturated GAC was then used as a cathode under 100 mA for the electro-Fenton reaction with the addition of 0.2 mM FeSO4. The primary products from HO oxidizing benzoic acid were mainly o-, m-, and p-hydroxybenzoic acid, and the stoichiometric ratio of HO to produced p-hydroxybenzoic acid was determined to be 5.87 ± 0.18 [34]. Hence, HO yield was calculated from p-hydroxybenzoic acid concentration multiplied by 5.87. p-Hydroxybenzoic acid concentration was measured with a high-performance liquid chromatography (HPLC, Agilent 1200 Infinity Series) equipped with an Agilent Eclipse AAA C18 column (4.6 × 150 mm) with 0.5 mL/min methanol/1% phosphoric acid (20/80) used as the mobile phase and p-hydroxybenzoic acid with a retention time of 5 min and was detected at 210 nm wavelength using an Agilent 1260 diode array detector.

3.6. Current Efficiency Calculation

The current efficiency (CE) for H2O2 generation, defined as the ratio of the electrons consumed by the two-electron oxygen reduction reaction over the total electrons passing through the circuit, was calculated by Equation (8).
C E = n F C H 2 O 2 V 0 t I d t × 100 %
where n is the number of electrons transferred for O2 reduction to H2O2, F is the Faraday constant (96486 C/mol), CH2O2 is the concentration of H2O2 (mol/L), V is the electrolyte volume (L), I (A) is the current at time t, and t is the reaction time (s).

3.7. Reusability Assay of Granular Activated Carbon

After each round of the electro-Fenton reaction, GAC was washed with 0.1 M H2SO4 acid solution to dissolve iron precipitates under vigorous stirring for 3 h. The cleaned GAC particles were then collected and rinsed with Milli-Q water to remove residual acid until eluent liquid had neutral pH. The regenerated GAC was further dried in an oven at 80 °C for 2–3 h prior to utilization as a cathode for the subsequent electro-Fenton process.

3.8. Disinfection of Antibiotic-Resistant Bacteria

E. coli K12 strains harboring ampicillin-, kanamycin-, tetracycline-, chloramphenicol-, zeocin-, and spectinomycin-resistance biomarkers were obtained by transferring pET-32a(+), pET24a(+), pTet, pCam, pCC-zeo, and pCC-spc plasmids (Figure S2 of Supplementary Material), respectively, into E. coli K12 competent cells. The bacteria with successful transfers of the biomarker gene were selected on an LB-agar plate with corresponding antibiotics (i.e., 30 μg/mL ampicillin, 50 μg/mL kanamycin, 20 μg/mL tetracycline, 20 μg/mL chloramphenicol, 25 μg/mL zeocin, and 100 μg/mL spectinomycin). Then, 108 CFU/mL of various antibiotic-resistant E. coli cells in the log phase were disinfected by the electro-Fenton process using GAC cathode under 100 mA with 10 mM Na2SO4 electrolyte and 0.2 mM FeSO4 at pH 7.

3.9. Chick–Watson Model

In the Chick–Watson model, the bacterial disinfection efficiency (ln(N/N0)) is correlated with both disinfectant concentration (C) and contact time (T), which can be expressed as:
ln(N/N0) = ΛCWCT
where ΛCW is the Chick–Watson coefficient. Electric current, generated H2O2, and produced HO as input disinfectants were investigated individually. Specifically, CT value for electric current was 0.1 t (A•min) under a constant 100 mA current.
For CT value of generated H2O2:
0 t [ H 2 O 2 ] t d t 0 t 0.5 ( [ H 2 O 2 ] t + [ H 2 O 2 ] t + Δ t ) Δ t
For CT value of produced HO:
0 t [ HO ] t d t 0 t 0.5 ( [ HO ] t + [ HO ] t + Δ t ) Δ t
During disinfection experiments, the steady-state HO concentration was estimated using a similar approach to Cho et al. [38] by adding 0.5 mM benzoic acid as a probe compound. The decay of benzoic acid obeyed the following equations:
HO + benzoic acid → products
d [ b e n z o i c   a c i d ] d t = k 7 [ HO ] [ b e n z o i c   a c i d ]
[ HO ] t = d [ b e n z o i c   a c i d ] k 7 [ b e n z o i c   a c i d ] d t 2 Δ [ b e n z o i c   a c i d ] k 7 ( [ b e n z o i c   a c i d ] t + [ b e n z o i c   a c i d ] t + Δ t ) Δ t
where k7 is 1.8 × 109 M−1 s−1 [54].

4. Conclusions

In this work, we used activated carbon as a cathode to generate H2O2 for the purpose of water disinfection. Ferrous ions were added to transform H2O2 into strong bactericide HO. Parameters including GAC loading, currents, solution pH, and reactor volume were investigated. The highest concentration of H2O2 reached 20.36 mg/L under optimal conditions. With ferrous ions, H2O2 was transformed into HO to inactivate E. coli. This electro-Fenton process could inactivate 108 CFU/mL E. coli after 300 min regardless of bacterial ARGs. Moreover, the electro-Fenton process automatically acidified the solution and was resistant to a high concentration of buffering carbonates in water. Considering the cost-effectiveness of GAC, this electro-Fenton process is promising in practical water treatment applications. Future work includes the upscaling of this process to test its feasibility in large-scale practice.

Supplementary Materials

The following are available online at https://www.mdpi.com/2073-4344/9/7/601/s1, Figure S1: Schematic representation of used reactor at (a) top view and (b) side view. a, 2.5 cm; b, 3.5 cm; h, 7 cm, Figure S2: Maps of used plasmids in this study to endow corresponding antibiotic resistance, Figure S3: E. coli inactivation by (a) electrolysis, MOPS buffer or thiourea, (b) hydrogen peroxide, (c) iron ions, and (d) acidic pH, Figure S4: Electro-Fenton process disinfection performance towards E. coli of different antibiotic-resistances including control experiments during 60 min.

Author Contributions

Conceptualization, A.N.A.; formal analysis, L.C.; investigation, L.C.; data curation, L.C.; writing—original draft preparation, L.C.; writing—review and editing, L.C., A.P., and A.N.A.; supervision, A.N.A.; funding acquisition, A.N.A.

Funding

This work was partially supported by the US National Institute of Environmental Health Sciences (NIEHS, Grant No. P42ES017198).

Acknowledgments

The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIEHS. The authors would like to thank Zhi Li for her support on figure drawing and manuscript reviewing. The authors would also like to thank Wei Zhou for the characterization of activated carbon, and Chuan Chen for helping with transformation of plasmids into E. coli competent cells.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Prüss-Ustün, A.; Bartram, J.; Clasen, T.; Colford, J.M., Jr.; Cumming, O.; Curtis, V.; Bonjour, S.; Dangour, A.D.; De France, J.; Fewtrell, L.; et al. Burden of disease from inadequate water, sanitation and hygiene in low- and middle-income settings: a retrospective analysis of data from 145 countries. Trop. Med. Int. Health 2014, 19, 894–905. [Google Scholar] [CrossRef]
  2. Langwig, K.E.; Frick, W.F.; Reynolds, R.; Parise, K.L.; Drees, K.P.; Hoyt, J.R.; Cheng, T.L.; Kunz, T.H.; Foster, J.T.; Kilpatrick, A.M. Host and pathogen ecology drive the seasonal dynamics of a fungal disease, white-nose syndrome. Proc. R. Soc. B 2015, 282, 20142335. [Google Scholar] [CrossRef]
  3. Zyara, A.M.; Torvinen, E.; Veijalainen, A.M.; Heinonen-Tanski, H. The effect of UV and combined chlorine/UV treatment on coliphages in drinking water disinfection. Water 2016, 8, 130. [Google Scholar] [CrossRef]
  4. Yoon, Y.; Chung, H.J.; Di, D.Y.W.; Dodd, M.C.; Hur, H.G.; Lee, Y. Inactivation efficiency of plasmid-encoded antibiotic resistance genes during water treatment with chlorine, UV, and UV/H2O2. Water Res. 2017, 123, 783–793. [Google Scholar] [CrossRef]
  5. Rajab, M.; Heim, C.; Letzel, T.; Drewes, J.E.; Helmreich, B. Electrochemical disinfection using boron-doped diamond electrode – the synergetic effects of in situ ozone and free chlorine generation. Chemosphere 2015, 121, 47–53. [Google Scholar] [CrossRef]
  6. Malik, M.A.; Hughes, D.; Heller, R.; Schoenbach, R. Surface plasmas versus volume plasma: energy deposition and ozone generation in air and oxygen. Plasma Chem. Plasma Process. 2015, 35, 697–704. [Google Scholar] [CrossRef]
  7. Chen, L.; Rajic, L.; Zhao, Y.; Hetrick, K.; Hojabri, S.; Alshawabkeh, A.; Xue, Y.; Zhou, W. Environmental Remediation with Electrochemical Technologies. In Kirk-Othmer Encyclopedia of Chemical Technology; John Wiley & Sons, Inc.: New York, NY, USA, 2018; pp. 1–34. [Google Scholar]
  8. Doederer, K.; Gernjak, W.; Weinberg, H.S.; Farré, M.J. Factors affecting the formation of disinfection by-products during chlorination and chloramination of secondary effluent for the production of high quality recycled water. Water Res. 2014, 48, 218–228. [Google Scholar] [CrossRef]
  9. Liu, C.; Olivares, C.I.; Pinto, A.J.; Lauderdale, C.V.; Brown, J.; Selbes, M.; Karanfil, T. The control of disinfection byproducts and their precursors in biologically active filtration processes. Water Res. 2017, 124, 630–653. [Google Scholar] [CrossRef]
  10. Rodriguez, R.A.; Bounty, S.; Beck, S.; Chan, C.; McGuire, C.; Linden, K.G. Photoreactivation of bacteriophages after UV disinfection: Role of genome structure and impacts of UV source. Water Res. 2014, 55, 143–149. [Google Scholar] [CrossRef]
  11. Song, K.; Mohseni, M.; Taghipour, F. Application of ultraviolet light-emitting diodes (UV-LEDs) for water disinfection: A review. Water Res. 2016, 94, 341–349. [Google Scholar] [CrossRef]
  12. Oguma, K.; Katayama, H.; Mitani, H.; Morita, S.; Hirata, T.; Ohgaki, S. Determination of pyrimidine dimers in Escherichia coli and Cryptosporidium parvum during UV light inactivation, photoreactivation, and dark repair. Appl. Environ. Microbiol. 2001, 67, 4630–4637. [Google Scholar] [CrossRef] [PubMed]
  13. Oguma, K.; Kita, R.; Sakai, H.; Murakami, M.; Takizawa, S. Application of UV light emitting diodes to batch and flow-through water disinfection system. Desalination 2013, 328, 24–30. [Google Scholar] [CrossRef]
  14. Sanz, E.N.; Davila, I.S.; Balao, J.A.A.; Alonso, J.M.Q. Modelling of reactivation after UV disinfection: Effect of UV-C dose on subsequent photoreactivation and dark repair. Water Res. 2007, 41, 3141–3151. [Google Scholar] [CrossRef] [PubMed]
  15. Ikai, H.; Nakamura, K.; Shirato, M.; Kanno, T.; Iwasawa, A.; Sasaki, K.; Niwano, Y.; Kohno, M. Photolysis of hydrogen peroxide, an effective disinfection system via hydroxyl radical formation. Antimicrob. Agents Chemother. 2010, 54, 5086–5091. [Google Scholar] [CrossRef] [PubMed]
  16. Mamane, H.; Shemer, H.; Linden, K.G. Inactivation of E. coli, B. subtilis spores, and MS2, T4, and T7 phage using UV/H2O2 advanced oxidation. J. Hazard. Mater. 2007, 146, 479–486. [Google Scholar] [CrossRef] [PubMed]
  17. Cabiscol, E.; Tamarit, J.; Ros, J. Oxidative stress in bacteria and protein damage by reactive oxygen species. Int. Microbiol. 2000, 3, 3–8. [Google Scholar] [PubMed]
  18. Bai, M.; Zhang, Z.; Xue, X.; Yang, X.; Hua, L.; Fan, D. Killing effects of hydroxyl radical on algae and bacteria in ship’s ballast water and on their cell morphology. Plasma Chem. Plasma Process. 2010, 30, 831–840. [Google Scholar] [CrossRef]
  19. Hydrogen Peroxide Price. Available online: https://www.kemcore.com/hydrogen-peroxide-50.html (accessed on 12 April 2019).
  20. Qiang, Z.; Chang, J.H.; Huang, C.P. Electrochemical generation of hydrogen peroxide from dissolved oxygen in acidic solutions. Water Res. 2002, 36, 85–94. [Google Scholar] [CrossRef]
  21. Panizza, M.; Cerisola, G. Removal of organic pollutants from industrial wastewater by electrogenerated Fenton’s reagent. Water Res. 2001, 35, 3987–3992. [Google Scholar] [CrossRef]
  22. Brillas, E.; Sirés, I.; Oturan, M.A. Electro-Fenton process and related electrochemical technologies based on Fenton’s reaction chemistry. Chem. Rev. 2009, 109, 6570–6631. [Google Scholar] [CrossRef]
  23. Zhou, L.; Zhou, M.; Hu, Z.; Bi, Z.; Serrano, K.G. Chemically modified graphite felt as an efficient cathode in electro-Fenton for p-nitrophenol degradation. Electrochim. Acta 2014, 140, 376–383. [Google Scholar] [CrossRef] [Green Version]
  24. Zhang, X.; Huang, Y.; Chen, X.; Gao, Q.; Zhang, W. Nitrogen-doped carbon nanotubes based on melamine-formaldehyde resin as highly efficient catalyst for oxygen reduction reaction. J. Colloid Interface Sci. 2018, 509, 1–9. [Google Scholar] [CrossRef] [PubMed]
  25. Alexeyeva, N.; Shulga, E.; Kisand, V.; Kink, I.; Tammeveski, K. Electroreduction of oxygen on nitrogen-doped carbon nanotube modified glassy carbon electrodes in acid and alkaline solutions. J. Electroanal. Chem. 2010, 648, 169–175. [Google Scholar] [CrossRef]
  26. Dąbrowski, A.; Podkościelny, P.; Hubicki, Z.; Barczak, M. Adsorption of phenolic compounds by activated carbon - a critical review. Chemosphere 2005, 58, 1049–1070. [Google Scholar] [CrossRef] [PubMed]
  27. Xiong, Y.; He, C.; Karlsson, H.T.; Zhu, X. Performance of three-phase three-dimensional electrode reactor for the reduction of COD in simulated wastewater-containing phenol. Chemosphere 2003, 50, 131–136. [Google Scholar] [CrossRef]
  28. Zhou, W.; Rajic, L.; Chen, L.; Kou, K.; Ding, Y.; Meng, X.; Wang, Y.; Mulaw, B.; Gao, J.; Qin, Y.; et al. Activated carbon as effective cathode material in iron-free Electro-Fenton process: Integrated H2O2 electrogeneration, activation, and pollutants adsorption. Electrochim. Acta 2019, 296, 317–326. [Google Scholar] [CrossRef]
  29. Lu, Z.; Chen, G.; Siahrostami, S.; Chen, Z.; Liu, K.; Xie, J.; Liao, L.; Wu, T.; Lin, D.; Liu, Y.; et al. High-efficiency oxygen reduction to hydrogen peroxide catalysed by oxidized carbon materials. Nat. Catal. 2018, 1, 156–162. [Google Scholar] [CrossRef]
  30. Zhou, W.; Ding, Y.; Gao, J.; Kou, K.; Wang, Y.; Meng, X.; Wu, S.; Qin, Y. Green electrochemical modification of RVC foam electrode and improved H2O2 electrogeneration by applying pulsed current for pollutant removal. Environ. Sci. Pollut. Res. 2018, 25, 6015–6025. [Google Scholar] [CrossRef]
  31. Zarei, M.; Salari, D.; Niaei, A.; Khataee, A. Peroxi-coagulation degradation of C.I. Basic Yellow 2 based on carbon-PTFE and carbon nanotube-PTFE electrodes as cathode. Electrochim. Acta 2009, 54, 6651–6660. [Google Scholar]
  32. Yu, F.; Zhou, M.; Zhou, L.; Peng, R. A novel electro-Fenton process with H2O2 generation in a rotating disk reactor for organic pollutant degradation. Environ. Sci. Technol. Lett. 2014, 1, 320–324. [Google Scholar] [CrossRef]
  33. Chance, B.; Greenstein, D.S.; Roughton, F.J.W. The mechanism of catalase action. I. Steady-state analysis. Arch. Biochem. Biophys. 1952, 37, 301–321. [Google Scholar] [CrossRef]
  34. Zhou, X.; Mopper, K. Determination of photochemically produced hydroxyl radicals in seawater and freshwater. Mar. Chem. 1990, 30, 71–88. [Google Scholar] [CrossRef]
  35. Stadtman, E.R.; Levine, R.L. Free radical-mediated oxidation of free amino acids and amino acid residues in proteins. Amino Acids 2003, 25, 207–218. [Google Scholar] [CrossRef] [PubMed]
  36. Booth, I.R. Regulation of cytoplasmic pH in bacteria. Microbiol. Rev. 1985, 49, 359–378. [Google Scholar] [PubMed]
  37. Stadtman, E.R. Metal ion-catalyzed oxidation of proteins: biochemical mechanism and biological consequences. Free Radic. Biol. Med. 1990, 9, 315–325. [Google Scholar] [CrossRef]
  38. Cho, M.; Lee, Y.; Chung, H.; Yoon, J. Inactivation of Escherichia coli by photochemical reaction of ferrioxalate at slightly acidic and near-neutral pHs. Appl. Environ. Microbiol. 2004, 70, 1129–1134. [Google Scholar] [CrossRef]
  39. Glaze, W.H.; Kang, J.W.; Chapin, D.H. The Chemistry of Water Treatment Processes Involving Ozone, Hydrogen Peroxide and Ultraviolet Radiation. Ozone Sci. Eng. 1987, 9, 335–352. [Google Scholar] [CrossRef]
  40. Kumar, A.; Bisht, B.S.; Joshi, V.D.; Singh, A.K.; Talwar, A. Physical, chemical and bacteriological study of water from rivers of Uttarakhand. J. Hum. Ecol. 2010, 32, 169–173. [Google Scholar] [CrossRef]
  41. Hulicova-Jurcakova, D.; Seredych, M.; Lu, G.Q.; Bandosz, T.J. Combined effect of nitrogen- and oxygen- containing functional groups of microporous activated carbon on its electrochemical performance in supercapacitors. Adv. Funct. Mater. 2009, 19, 438–447. [Google Scholar] [CrossRef]
  42. Piddock, L.J.V. Clinically relevant chromosomally encoded multidrug resistance efflux pumps in bacteria. Clin. Microbiol. Rev. 2006, 19, 382–402. [Google Scholar] [CrossRef]
  43. Ochman, H.; Lawrence, J.G.; Groisman, E.A. Lateral gene transfer and the nature of bacterial innovation. Nature 2000, 405, 299–304. [Google Scholar] [CrossRef] [PubMed]
  44. Rizzo, L.; Manaia, C.; Merlin, C.; Schwartz, T.; Dagot, C.; Ploy, M.C.; Michael, I.; Fatta-Kassinos, D. Urban wastewater treatment plants as hotspots for antibiotic resistant bacteria and genes spread into the environment: A review. Sci. Total Environ. 2013, 447, 345–360. [Google Scholar] [CrossRef] [PubMed]
  45. GAC Price. Available online: https://www.prnewswire.com/news-releases/global-and-china-activated-carbon-market-2017-2021---6-foreign-and-19-chinese-activated-carbon-enterprises-300502107.html (accessed on 12 April 2019).
  46. Schröder, E.; Thomauske, K.; Weber, C.; Hornung, A.; Tumiatti, V. Experiments on the generation of activated carbon from biomass. J. Anal. Appl. Pyrolysis 2007, 79, 106–111. [Google Scholar] [CrossRef]
  47. Dias, J.M.; Alvim-Ferraz, M.C.M.; Almeida, M.F.; Rivera-Utrilla, J.; Sánchez-Polo, M. Waste materials for activated carbon preparation and its use in aqueous-phase treatment: A review. J. Environ. Manage. 2007, 85, 833–846. [Google Scholar] [CrossRef] [PubMed]
  48. Krembs, F.J.; Siegrist, R.L.; Crimi, M.L.; Furrer, R.F.; Petri, B.G. ISCO for groundwater remediation: analysis of field applications and performance. Ground Water Monit. Remediat. 2010, 30, 42–53. [Google Scholar] [CrossRef]
  49. Thomson, N.R.; Hood, E.D.; Farquhar, G.J. Permanganate treatment of an emplaced DNAPL source. Ground Water Monit. Remediat. 2007, 27, 74–85. [Google Scholar] [CrossRef]
  50. Chen, L.; Tang, M.; Chen, C.; Chen, M.; Luo, K.; Xu, J.; Zhou, D.; Wu, F. Efficient bacterial inactivation by transition metal catalyzed auto-oxidation of sulfite. Environ. Sci. Technol. 2017, 51, 12663–12671. [Google Scholar] [CrossRef] [PubMed]
  51. Chen, L.; Li, Z.; Chen, M. Facile production of silver-reduced graphene oxide nanocomposite with highly effective antibacterial performance. J. Environ. Chem. Eng. 2019, 7, 103160. [Google Scholar] [CrossRef]
  52. Chen, L.; Peng, Y.; Tang, M.; Wu, F. Comment on “Combination of cupric ion with hydroxylamine and hydrogen peroxide for the control of bacterial biofilms on RO membranes by Hye-Jin Lee, Hyung-Eun Kim, Changha Lee [Water Research 110, 2017, 83–90]”. Water Res. 2017, 118, 289–290. [Google Scholar] [CrossRef]
  53. Eisenberg, G. Colorimetric determination of hydrogen peroxide. Ind. Eng. Chem. Anal. Ed. 1943, 15, 327–328. [Google Scholar] [CrossRef]
  54. Ashton, L.; Buxton, G.V.; Stuart, C.R. Temperature dependence of the rate of reaction of OH with some aromatic compounds in aqueous solution. Evidence for the formation of a π-complex intermediate? J. Chem. Soc. Faraday Trans. 1995, 91, 1631–1633. [Google Scholar] [CrossRef]
Figure 1. Impact of (a) ferrous iron ion concentration and (b) GAC cathode current intensity on hydroxyl radical generation during the electro-Fenton process. Conditions: (a) 3 g GAC as cathode under 100 mA current, pHini 7; (b) 3 g GAC as cathode, 0.2 mM FeSO4, pHini 7.
Figure 1. Impact of (a) ferrous iron ion concentration and (b) GAC cathode current intensity on hydroxyl radical generation during the electro-Fenton process. Conditions: (a) 3 g GAC as cathode under 100 mA current, pHini 7; (b) 3 g GAC as cathode, 0.2 mM FeSO4, pHini 7.
Catalysts 09 00601 g001
Figure 2. (a) GAC as the cathode to produce hydrogen peroxide and hydroxyl radical after addition of iron ions and (b) generated hydroxyl radical inactivated E. coli. Conditions: 3 g GAC as cathode under 100 mA current, 0.2 mM FeSO4, 108 CFU/mL (CFU, colony forming unit) E. coli, pHini 7.
Figure 2. (a) GAC as the cathode to produce hydrogen peroxide and hydroxyl radical after addition of iron ions and (b) generated hydroxyl radical inactivated E. coli. Conditions: 3 g GAC as cathode under 100 mA current, 0.2 mM FeSO4, 108 CFU/mL (CFU, colony forming unit) E. coli, pHini 7.
Catalysts 09 00601 g002
Figure 3. Yields of hydrogen peroxide and hydroxyl radical during electro-Fenton process after addition of (a) 50 mM MOPS buffer or (b) 50 mM thiourea and (c) performance of bacterial disinfection performance. Conditions: 3 g GAC as cathode under 100 mA current, 0.2 mM FeSO4, 108 CFU/mL E. coli, pHini 7. Control indicates electro-Fenton process.
Figure 3. Yields of hydrogen peroxide and hydroxyl radical during electro-Fenton process after addition of (a) 50 mM MOPS buffer or (b) 50 mM thiourea and (c) performance of bacterial disinfection performance. Conditions: 3 g GAC as cathode under 100 mA current, 0.2 mM FeSO4, 108 CFU/mL E. coli, pHini 7. Control indicates electro-Fenton process.
Catalysts 09 00601 g003
Figure 4. (a) Yields of hydrogen peroxide and hydroxyl radical by electro-Fenton process during 300 min reaction and (b) bacterial disinfection performances at different bacteria concentrations. Conditions: 3 g GAC as cathode under 100 mA current, 0.2 mM FeSO4, 108 CFU/mL E. coli, pHini 7. E. coli concentration in (b) varied as indicated.
Figure 4. (a) Yields of hydrogen peroxide and hydroxyl radical by electro-Fenton process during 300 min reaction and (b) bacterial disinfection performances at different bacteria concentrations. Conditions: 3 g GAC as cathode under 100 mA current, 0.2 mM FeSO4, 108 CFU/mL E. coli, pHini 7. E. coli concentration in (b) varied as indicated.
Catalysts 09 00601 g004
Figure 5. Chick–Watson model fitting with (a) electric current, (b) generated hydrogen peroxide, and (c) produced hydroxyl radical as input disinfectant.
Figure 5. Chick–Watson model fitting with (a) electric current, (b) generated hydrogen peroxide, and (c) produced hydroxyl radical as input disinfectant.
Catalysts 09 00601 g005
Figure 6. Effect of carbonate on hydrogen peroxide production or bacterial disinfection at (a) 1 mM or (b) 2 mM. Conditions: 3 g GAC as cathode under 100 mA current, 0.2 mM FeSO4, 108 CFU/mL E. coli. Carbonate concentration was indicated. Reaction solution was adjusted to pH 7 after addition of carbonate ions.
Figure 6. Effect of carbonate on hydrogen peroxide production or bacterial disinfection at (a) 1 mM or (b) 2 mM. Conditions: 3 g GAC as cathode under 100 mA current, 0.2 mM FeSO4, 108 CFU/mL E. coli. Carbonate concentration was indicated. Reaction solution was adjusted to pH 7 after addition of carbonate ions.
Catalysts 09 00601 g006
Figure 7. Reusability of GAC cathode for (a) hydrogen peroxide production and (b) bacterial disinfection. Conditions: 3 g GAC as cathode under 100 mA current, 0.2 mM FeSO4, 108 CFU/mL E. coli, pHini 7.
Figure 7. Reusability of GAC cathode for (a) hydrogen peroxide production and (b) bacterial disinfection. Conditions: 3 g GAC as cathode under 100 mA current, 0.2 mM FeSO4, 108 CFU/mL E. coli, pHini 7.
Catalysts 09 00601 g007
Figure 8. Electro-Fenton process disinfection performance towards E. coli of different antibiotic resistances. Conditions: 3 g GAC as cathode under 100 mA current, 0.2 mM FeSO4, 108 CFU/mL E. coli, pHini 7. Ampr, ampicillin-resistant; Kanr, kanamycin-resistant; Tetr, tetracycline-resistant; Camr, chloramphenicol-resistant; Zeor, zeocyin-resistant; Spcr, spectinomycin-resistant.
Figure 8. Electro-Fenton process disinfection performance towards E. coli of different antibiotic resistances. Conditions: 3 g GAC as cathode under 100 mA current, 0.2 mM FeSO4, 108 CFU/mL E. coli, pHini 7. Ampr, ampicillin-resistant; Kanr, kanamycin-resistant; Tetr, tetracycline-resistant; Camr, chloramphenicol-resistant; Zeor, zeocyin-resistant; Spcr, spectinomycin-resistant.
Catalysts 09 00601 g008
Table 1. Yields of hydrogen peroxide and determined current efficiencies after reaction for 60 min under various conditions.
Table 1. Yields of hydrogen peroxide and determined current efficiencies after reaction for 60 min under various conditions.
Granular Activated Carbon (GAC) Amount (g)pHiniCurrent (mA)Volume (mL)Granularity (mesh)pHfinalH2O2 Yield (mg/L)Current Efficiency
171002004–83.54 ± 0.164.12 ± 0.191.30%
271002004–83.51 ± 0.147.44 ± 0.302.35%
371002004–83.42 ± 0.1114.64 ± 0.654.62%
331002004–82.85 ± 0.0720.36 ± 0.686.42%
351002004–83.44 ± 0.1314.90 ± 0.684.70%
391002004–83.46 ± 0.1413.03 ± 0.524.11%
3111002004–83.77 ± 0.1912.74 ± 0.464.02%
37502004–84.21 ± 0.143.38 ± 0.112.13%
37752004–84.04 ± 0.185.79 ± 0.262.43%
371502004–83.49 ± 0.1410.70 ± 0.432.25%
371001504–83.41 ± 0.1216.34 ± 0.593.86%
371003004–83.51 ± 0.1212.47 ± 0.425.90%
371004004–83.49 ± 0.1610.69 ± 0.496.74%
371002004–123.42 ± 0.1414.37 ± 0.574.53%
371002004–143.47 ± 0.1311.66 ± 0.423.68%
37100200< 5 mm3.54 ± 0.1216.11 ± 0.545.08%

Share and Cite

MDPI and ACS Style

Chen, L.; Pinto, A.; Alshawabkeh, A.N. Activated Carbon as a Cathode for Water Disinfection through the Electro-Fenton Process. Catalysts 2019, 9, 601. https://doi.org/10.3390/catal9070601

AMA Style

Chen L, Pinto A, Alshawabkeh AN. Activated Carbon as a Cathode for Water Disinfection through the Electro-Fenton Process. Catalysts. 2019; 9(7):601. https://doi.org/10.3390/catal9070601

Chicago/Turabian Style

Chen, Long, Ameet Pinto, and Akram N. Alshawabkeh. 2019. "Activated Carbon as a Cathode for Water Disinfection through the Electro-Fenton Process" Catalysts 9, no. 7: 601. https://doi.org/10.3390/catal9070601

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop