Intelligent Genetic Decoding System Based on Nucleic Acid Isothermal Amplification for Non-Small Cell Lung Cancer Diagnosis

1
College of Forensic Medicine, Shanxi Medical University, Taiyuan 030001, China
2
College of Life Sciences, Northwest University, Xi’an 710069, China
*
Author to whom correspondence should be addressed.
These authors contributed equally to this work.
Micromachines 2023, 14(3), 647; https://doi.org/10.3390/mi14030647
Submission received: 30 January 2023 / Revised: 26 February 2023 / Accepted: 10 March 2023 / Published: 12 March 2023
(This article belongs to the Special Issue Nucleic-Acid-Based Intelligent Systems)

Abstract

:
Non-small cell lung cancer (NSCLC) is a major cause of cancer-related deaths around the world. Targeting the sensitized epidermal growth factor receptor (EGFR) caused by gene mutation through the tyrosine kinase inhibitor is an effective therapeutic strategy for NSCLC. Hence, the individualized therapeutic strategy has highlighted the demand for a simple, fast, and intelligent strategy for the genetic decoding of EGFR to cater to the popularization of precision medicine. In this research, a one-pot assay for EGFR identification is established by combining a loop-mediated isothermal amplification and amplification refractory mutation system. By optimizing the component and condition of the nucleic acid amplification system, a sensitive and specific distinguishability is achieved for tracing target variant (60 copies, 0.1%) identification under a strong interferential background within 40 min. Moreover, complex operation and time-consuming data processing, as well as the aerosol contamination, are avoided owing to the whole process for intelligent genetic decoding being performed in a sealed tube. As a demonstration, L858R, the primary point mutation for the sensitization of EGFR, has been accurately decoded using this assay with highly heterogeneous cancerous tissue. In addition, this method can be easily extended for other genetic information decoding using a tailor-made primer set. Thus, we propose that this straightforward strategy may serve as a promising tool for NSCLC diagnosis in clinical practice.

1. Introduction

Lung cancer is a primary malignant tumor with a high incidence and mortality rate worldwide; non-small cell lung cancer (NSCLC) is the dominating subtype of lung cancer, which accounts for approximately 85% of these cases [1,2]. Along with the comprehensive molecular profiling of cancer-related genes, the insight into cancer treatment has been revolutionized and targeting the epidermal growth factor receptor (EGFR) through the tyrosine kinase inhibitor (TKI) has been regarded as an effective therapeutic strategy for NSCLC from a clinical oncology perspective [3,4]. However, the response of NSCLC patients to TKI therapy seriously depends on the mutant status in exons 18–21 of EGFR, which code for the tyrosine kinase domain [5,6]. Among these mutations, the L858R located in exon 21, which causes a leucine–arginine substitution at codon 858, is the primary point mutation, which comprises about 41% of all activating mutations that confer sensitivity to TKI therapy [5,7]. Hence, the L858R point mutation of EGFR is a crucial biomarker for decision making in the treatment of NSCLC to obtain the individualized therapeutic strategy for patients. Moreover, the mutant status of EGFR should be decoded as soon as possible to provide timely personalized therapy due to most NSCLC patients being diagnosed in the advanced or metastatic stages. Hence, the strategies for EGFR mutation identification should meet the requirement of the speediness and convenience for the point of care test (POCT), which is defined as the test being performed near the patient and the result potentially leading to a preferable therapy for the patient [8].
As EGFR mutation is highly responsive to TKI therapy in NSCLC treatment, EGFR mutation decoding has attracted extensive attention and a variety of strategies have been established. The therascreen EGFR RGQ PCR Kit (Qiagen Co., Ltd., Hilden, Germany) is developed based on real-time PCR for the detection of 21 EGFR mutations located in exons 18–21; this commercial kit has been approved as a companion diagnosis for NSCLC by the United States Food and Drug Administration [9,10]. In addition, massively paralleled DNA sequencing, which enables millions of target genes to be sequenced simultaneously, has been introduced into EGFR mutation decoding and screening [11,12]. However, due to the sophisticated equipment and time-consuming procedure, as well as the complex data analysis necessary with these methods, it is difficult to satisfy the demand for the speediness and convenience for POCT in clinical practice. Hence, a simple and fast strategy for EGFR mutation identification is still desired for providing timely genetic information in NSCLC personalized treatment.
Loop-mediated isothermal amplification (LAMP) is an excellent nucleic acid amplification technology under the isothermal condition that has been widely used in pathogen detection [13,14,15]. Compared with PCR, by employing more primers and higher primer concentration, LAMP exhibits higher sensitivity and specificity, as well as a higher amplification efficiency [13]. Furthermore, the expensive thermocycler is free for LAMP, which reduces the testing cost in medical institutions, especially in resource-constraint settings. Taking advantage of LAMP, some methods based on LAMP have been established for EGFR mutation decoding, including the LAMP-based melting curve [9,16], LAMP-based microfluidic device [17,18], and LAMP-based lateral flow device [19]. However, the melting curve process weakens the speediness of LAMP by lengthening the detection time and the fabrication of microfluidics and the lateral flow device increases the testing cost. Although these LAMP-based strategies are not popularized in clinical practice, LAMP still provides a simple, rapid, and low-cost approach for EGFR mutation identification.
In this research, by combining LAMP and amplification refractory mutation system (ARMS), a simple, fast, and low-cost strategy for intelligent EGFR decoding, named One-Pot-LAMP, is established, which can provide timely genetic information within 40 min for personalized NSCLC treatment. Moreover, the false positive result from aerosol contamination is avoided owing to the result being directly interpreted in a sealed tube during the whole process. In addition, further complex operations and time-consuming data analysis are avoided as well. The combination of speediness and convenience causes this assay to be a great candidate for NSCLC diagnosis in POCT scenarios.

2. Materials and Methods

2.1. Oligonucleotide

To establish One-Pot-LAMP, two primer sets for EGFR L858R decoding were designed using the Primer 5.0 software program (Primer-E Co., Ltd., Plymouth, UK). For convenience, mutant and wild type are noted as “M” and “WT”, respectively, in this research. The M primer set includes two M inner primers (FIP m and BIP-M) for recognizing the mutant variant and two outer primers (F3 and B3). The WT primer set includes two WT inner primers (FIP-WT and BIP-WT) for recognizing the wild-type variant, as well as two outer primers (F3 and B3). In addition, two primers were designed as well for plasmid construction and DNA sequencing. All the primers were synthesized, Invitrogen Biotechnology Co., Ltd. (Shanghai, China) (Table S1 and Figure S1).

2.2. Plasmid Construction

Two plasmids containing the sequences of wild-type or L858R mutation of EGFR, respectively, were constructed using a pMD19-T Vector Cloning Kit (Takara Co., Ltd., Dalian, China). Then, the recombinant plasmids were transformed into the Escherichia coli DH5α cells (Takara Co., Ltd.) and extracted using a TIANprep Mini Plasmid Kit (Tiangen Biotech Co., Ltd., Beijing, China). All the plasmids were confirmed through DNA sequencing by Beijing Genomic Institute (Beijing, China) and the concentrations were determined using a NanoDrop 2000 UV–Vis spectrophotometer (Thermo Fisher Scientific Co., Ltd., Wilmington, DE, USA).

2.3. Cell Culture and Clinical Sample

Two lung cancer cell lines containing L858R point mutation (NCI-H1975) and the wild-type variant (A549) of EGFR as the simulative positive and negative specimens, respectively, were purchased from Procell Life Science Co., Ltd. (Wuhan, China). The cell lines were cultured in the RPMI 1640 medium (HyClone Co., Ltd., Logan, UT, USA) with 10% fetal bovine serum (Gemini Bio Co., Ltd., West Sacramento, CA, USA) using a cell incubator (MCO-5AC, SANYO Electric Co., Ltd., Osaka, Japan) at 37 °C with 5% CO2. The cells at the logarithmic phase were detached using 0.25% trypsin-EDTA (Gibco Co., Ltd., Grand Island, NY, USA) for the subsequent study.
The cancerous tissues were surgically resected from 40 patients diagnosed with non-small cell lung cancer by the expert pathologist at the First Affiliated Hospital of Xi’an Jiaotong University (Xi’an, China) with informed consent. Then, all the cancerous tissues were formalin-fixed and paraffin-embedded for the subsequent study. This research was approved by the Ethics Committee of the College of Life Sciences, Northwest University (Xi’an, China), and all human-related protocols were performed in accordance with the Declaration of Helsinki.

2.4. Genomic DNA Purification

The genomic DNA from the cell lines and formalin-fixed and paraffin-embedded cancerous tissue were extracted using a TIANamp Genomic DNA Kit (Tiangen Biotech Co., Ltd.) and a TIANquick FFPE DNA Kit (Tiangen Biotech Co., Ltd.), respectively. The concentrations were further determined using a NanoDrop 2000 UV–Vis spectrophotometer.

2.5. One-Pot-LAMP Design

For the EGFR L858R decoding using this method, two paralleled amplification reactions (M tube added with M primer set and WT tube added with a WT primer set) were simultaneously performed for each specimen determination by recognizing the mutant variant (M reaction) and wild-type variant (WT reaction). For each amplification, a 25 μL reaction mixture containing 15 μL of Isothermal Master Mix (OptiGene Co., Ltd., West Sussex, UK), 0.2 µM of F3 and B3, 1.0 µM of FIP and BIP, and genomic DNA from the specimen was incubated at 63 °C for 40 min and the amplification kinetics were obtained in real time using a fluorometer (OptiGene Co., Ltd.). To achieve the best discrimination between the two variants for EGFR decoding, the amplification component was optimized with different inner primer concentrations, and the amplification condition was optimized using different incubation temperatures as well.

3. Results

3.1. One-Pot-LAMP Design

ToTo decode the L858R located in EGFR, a pair of inner primers were correspondingly tailor-made for recognizing the target variant through their DNA sequences. The point mutant nucleotide of L858R was located between the F1 and B1c regions and the two regions overlapped in this mutant nucleotide. Hence, the crucial nucleotide of the primer set for decoding EGFR L858R was designed at the 5′ terminus of the inner primer. The six regions located in EGFR were well-chosen for amplification with high specificity from the whole human genome. Moreover, to achieve the best discrimination between the two variants, an additional mismatched nucleotide was introduced at the 5′ penultimate of the inner primer according to the principle of ARMS [20].
The mutant status of EGFR L858R was determined by the two parallel LAMP reactions. Specifically, double-stem-loop structures were formed through strand displacement in both reaction mixtures and served as the trigger for self-primed DNA synthesis. In the matched primer–variant tube, the double-stem-loop structure containing complementary nucleobase with the target variant would be formed, which resulted in exponential DNA amplification and the accumulation of stem-loop DNA with various stem lengths. However, the double-stem-loop structure containing a non-complementary nucleobase would be formed in the mismatched primer–variant tube, which failed to cause self-primed DNA synthesis. Therefore, the S-shaped amplification kinetic curve derived from the exponential DNA amplification would be observed only when the specimen contains the matched variant with the primer set (Figure 1).
The mutant status of EGFR L858R could be decoded according to the fluorescent signal derived from both amplification mixtures. For the mutant variant, a significant amplification signal could be observed in the M tube, while the wild-type variant led to an amplification signal only from the WT tube. Compared with the mismatched primer–variant pair, the matched primer–variant pair produced a significant S-shaped amplification kinetic curve, which facilitated determining the EGFR mutation status. For the negative control with deionized water as the template, the amplification kinetic curves were consistent with those from the mismatched primer–variant pair for both M and WT tubes (Figure 2A). Moreover, the amplification kinetic curve indicated that the accurate result could be provided within 40 min. As a reference, the amplicon from the LAMP was also analyzed using electrophoresis. The typical ladder-like pattern was observed from the matched primer–variant pair while the blank lane was observed from the mismatched primer–variant pair, which indicated that the S-shaped amplification kinetic curve was not caused by spurious amplification (Figure 2B). In addition, DNA sequencing was also employed to determine and obtain a perfect correlation (Figure 2C).

3.2. One-Pot-LAMP Optimization

To decode EGFR L858R with high sensitivity and specificity as fast as possible, the performance of the One-Pot-LAMP was optimized with different inner primer concentrations and different incubation temperatures. The plasmids containing the sequences of the wild-type or L858R mutations of EGFR, respectively, were employed to perform the optimization. For the optimal primer concentration, the performance of this method with different final concentrations (0.6, 0.8, 1.0, and 1.2 μM) of the inner primer in the reaction mixture was evaluated. Among all the tested concentrations of the inner primer, 0.6 and 0.8 μM were too low to trigger the amplification within 40 min in both matched and mismatched primer–variant pairs. While a distinct amplification signal was observed in the matched primer–variant pair, and the amplification signal was not observed in the mismatched pair when the inner primer concentration rose to 1.0 μM, which allowed for a clear discrimination between the wild-type and L858R mutations of EGFR. However, when the concentration rose to 1.2 μM, further non-specific amplification was observed in the mismatched primer–variant pair. Hence, 1.0 μM was selected as the optimal concentration of the inner primer in this assay (Figure 3). Based on the optimal inner primer concentration, the performance of this method with different incubation temperatures (62, 63, 64, and 65 °C) was also evaluated. Among all the tested temperatures, a distinct amplification signal was only observed in the matched primer–variant pair. However, the amplification signals in the M reaction mixture were deferred at 62, 64, and 65 °C compared with 63 °C, while the amplification signals in the WT reaction mixture were similar at 63 and 64 °C but earlier than those at 65 °C. Thus, 63 °C was chosen as the optimal temperature in this assay (Figure 4).

3.3. One-Pot-LAMP Performance

Subsequently, the performance of One-Pot-LAMP under the optimal condition was evaluated and plasmids were also employed as standard sequence control. Different plasmid mixtures containing 0% to 100% mutant plasmid diluted in wild-type plasmid with a final amount at 200 fg were prepared. The total plasmid mixture was added to the reaction mixture, respectively to evaluate the capacity of this method to recognize the target variant under interferential background. Distinct S-shaped amplification kinetic curves were observed for all test cases containing target variant within 40 min even when the target plasmid was as low as 0.1% (0.2 fg, approximately 60 copies). While no amplification signal was observed for the plasmid mixture containing no target variant, which indicated the high sensitivity and specificity of this method (Figure 5).

3.4. Cell Lines and Clinical Samples Analysis

Next, the performance of this method was further evaluated using the lung cancer cell lines and the EGFR L858R mutant statuses were identified using the 10 ng genomic DNA extracted from the NCI-H1975 and A549 cell lines, respectively. Significant amplification signals were observed from both M and WT reaction mixtures, which indicated that the EGFR L858R mutant status was a point mutation in NCI-H1975, while the S-shaped amplification kinetic curve was only observed from the WT reaction mixture, which indicated that the EGFR L858R mutant status was a wild-type variant in A549 (Figure 6). These results were consistent with those from the previous research [17,18]. Furthermore, the EGFR L858R mutant statuses of 40 cancerous tissues from 40 non-small cell lung cancer patients were also identified using this method. Among these real clinical specimens, 34 L858R mutation cases and 6 wild-type cases were observed. Meanwhile, the TaqMan-PCR EGFR Kit obtained from Life gene Co., Ltd. (Xi’an, China) was also employed to analyze these cancerous tissues for the double-blind trial. Compared to the results from the two methods, no discrepancy was observed, which indicated that this One-Pot-LAMP was able to accurately identify the EGFR L858R mutant status for clinical practice (Table 1).

4. Discussion

Lung cancer has been widely recognized as a seriously threatening tumor with a high incidence and mortality rate worldwide. NSCLC accounts for about 85% of all types of lung cancer [1,2]. In clinical practice, different genetic mutations of NSCLC in patients result in different therapeutic responses with the same drug [3,21]. Among these mutations, EGFR mutation has been found in approximately 35% of NSCLC patients in East Asia; the L858R located in the tyrosine kinase domain of EGFR is the most common point of mutation, accounting for about 41% of all EGFR mutations [7,22]. The mutant status of EGFR is highly responsible for the therapeutic effect of TKI, which is an effective therapeutic strategy for NSCLC [5,6]. Hence, individualized treatment is always desired by EGFR mutation decoding owing to the NSCLC patient survival rate being significantly improved by an early diagnosis [23]. For EGFR mutation decoding, LAMP is an excellent nucleic acid amplification technology that provides a simple, rapid, and intelligent approach; several LAMP-based methods have been developed for EGFR mutation detection [9,17,18,19]. However, the analysis of amplicons using LAMP lengthens the detection time and the fabrication of a micro device increases the testing cost. In this research, by combining LAMP and ARMS, the L858R point mutation of EGFR can be accurately identified through the optimal nucleic acid amplification system within 40 min, which is significantly simpler and faster than the methods mentioned above.
Cancerous tissue is highly heterogeneous and the genetic decoding method must be as sensitive as possible. For One-Pot-LAMP, by employing a tailor-made primer set targeting L858R mutation, high sensitivity and specificity are achieved to identify the trace of the target variant. As low as 0.1% (60 copies) of the target variants can be accurately decoded under a strong interferential background. Hence, the earlier diagnosis and individualized therapeutic strategy for NSCLC patients may be obtained for clinical practice. Moreover, this method is free of any expensive equipment and fluorescein-labeled oligonucleotide, which causes this method to be very low-cost and suitable for application in resource-limited medical institutions. In addition, time-consuming procedures and complex data analysis are avoided, which causes this method to be more convenient. Hence, the One-Pot-LAMP established here may serve as a promising tool for NSCLC diagnosis, therapy, and prognosis in POCT scenarios owing to its advantages of being simple, fast, and low-cost.
To achieve one-pot and intelligent EGFR decoding, the amplification signal of this nucleic acid system is employed for result interpretation. Hence, the primer set for the target variant is designed cautiously and the principle of ARMS was introduced to enhance the specificity. The formation of a double-stem-loop structure is a trigger for exponential DNA amplification. Hence, additional mismatched nucleotides at the 5′ penultimate of both FIP and BIP are designed, and the exponential DNA amplification only begins when the double-stem-loop structure contains a complementary nucleobase with the target variant. In addition, aerosol contamination, the major reason for false positive results in LAMP-based methods, was avoided, as the whole detection process is performed in a sealed tube.

5. Conclusions

In summary, One-Pot-LAMP, a simple, fast, and low-cost strategy for intelligent EGFR decoding, was established. It can provide timely genetic information within 40 min for personalized NSCLC treatment. One-Pot-LAMP not only achieves high sensitivity and specificity but can also be easily extended for other genetic information decoding using redesigned primer sets. The performance of One-Pot-LAMP was verified using real-world samples to determine the EGFR L858R mutation, which indicates the great potential of this straightforward strategy for NSCLC diagnosis in clinical practice.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/mi14030647/s1, Table S1: Primer sequences for One-Pot-LAMP and plasmid construction. Figure S1: The amplification kinetic curve of One-Pot-LAMP with different concentrations of inner primer.

Author Contributions

Conceptualization, X.L., J.Z. and K.H.; Data curation, X.L. and J.Z.; Funding acquisition, K.H.; Investigation, X.L. and J.Z.; Methodology, X.L. and J.Z.; Resources, X.L.; Supervision, X.L.; Writing—Original draft, X.L. and J.Z.; Writing—Review and editing, X.L. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the National Key Research and Development Program (2021YFC3300102) and the Natural Science Basic Research Plan in Shaanxi Province of China (2021JQ-443).

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki, and approved by the Ethics Committee of the College of Life Sciences, Northwest University (protocol code 210307008-1, 7 March 2021).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

The data are available within this article.

Acknowledgments

The authors thank Juan Jia for acquiring the fund to afford the article processing charges. Especially, Xiaonan Liu warmly congratulates Jiaxing Zhang on her happy wedding.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Sung, H.; Ferlay, J.; Siegel, R.L.; Laversanne, M.; Soerjomataram, I.; Jemal, A.; Bray, F. Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J. Clin. 2021, 71, 209–249. [Google Scholar] [CrossRef]
  2. Pao, W.; Girard, N. New driver mutations in non-small-cell lung cancer. Lancet Oncol. 2011, 12, 175–180. [Google Scholar] [CrossRef] [PubMed]
  3. Lynch, T.J.; Bell, D.W.; Sordella, R.; Gurubhagavatula, S.; Okimoto, R.A.; Brannigan, B.W.; Harris, P.L.; Haserlat, S.M.; Supko, J.G.; Haluska, F.G. Activating mutations in the epidermal growth factor receptor underlying responsiveness of non–small-cell lung cancer to gefitinib. N. Engl. J. Med. 2004, 350, 2129–2139. [Google Scholar] [CrossRef] [PubMed]
  4. Wu, Y.-L.; Zhou, C.; Hu, C.-P.; Feng, J.; Lu, S.; Huang, Y.; Li, W.; Hou, M.; Shi, J.H.; Lee, K.Y. Afatinib versus cisplatin plus gemcitabine for first-line treatment of Asian patients with advanced non-small-cell lung cancer harbouring EGFR mutations (LUX-Lung 6): An open-label, randomised phase 3 trial. Lancet Oncol. 2014, 15, 213–222. [Google Scholar] [CrossRef]
  5. Sharma, S.V.; Bell, D.W.; Settleman, J.; Haber, D.A. Epidermal growth factor receptor mutations in lung cancer. Nat. Rev. Cancer 2007, 7, 169–181. [Google Scholar] [CrossRef]
  6. Gazdar, A. Activating and resistance mutations of EGFR in non-small-cell lung cancer: Role in clinical response to EGFR tyrosine kinase inhibitors. Oncogene 2009, 28, S24–S31. [Google Scholar] [CrossRef] [Green Version]
  7. Harrison, P.T.; Vyse, S.; Huang, P.H. Rare epidermal growth factor receptor (EGFR) mutations in non-small cell lung cancer. Semin. Cancer Biol. 2020, 61, 167–179. [Google Scholar] [CrossRef]
  8. Luppa, P.; Junker, R. Point-of-care testing: Principles and clinical applications. J. Immunol. Methods 2018, 9, 69–79. [Google Scholar]
  9. Saito, Y.; Takahashi, N.; Matsui, A.; Michiyuki, S.; Yamauchi, Y.; Shimizu, Y.; Hoshi, E.; Sakao, Y.; Kawamura, M. Comparative study of the loop-mediated isothermal amplification method and the QIAGEN therascreen PCR kit for the detection of EGFR mutations in non-small cell lung cancer. J. Thorac. Dis. 2021, 13, 743. [Google Scholar] [CrossRef] [PubMed]
  10. Kazandjian, D.; Blumenthal, G.M.; Yuan, W.; He, K.; Keegan, P.; Pazdur, R. FDA approval of gefitinib for the treatment of patients with metastatic EGFR mutation–positive non–small cell lung cancer. Clin. Cancer Res. 2016, 22, 1307–1312. [Google Scholar] [CrossRef] [Green Version]
  11. Tan, A.C.; Lai, G.G.; San Tan, G.; Poon, S.Y.; Doble, B.; Lim, T.H.; Aung, Z.W.; Takano, A.; Tan, W.L.; Ang, M.-K. Utility of incorporating next-generation sequencing (NGS) in an Asian non-small cell lung cancer (NSCLC) population: Incremental yield of actionable alterations and cost-effectiveness analysis. Lung Cancer 2020, 139, 207–215. [Google Scholar] [CrossRef] [Green Version]
  12. Takeda, M.; Sakai, K.; Terashima, M.; Kaneda, H.; Hayashi, H.; Tanaka, K.; Okamoto, K.; Takahama, T.; Yoshida, T.; Iwasa, T. Clinical application of amplicon-based next-generation sequencing to therapeutic decision making in lung cancer. Ann. Oncol. 2015, 26, 2477–2482. [Google Scholar] [CrossRef]
  13. Notomi, T.; Okayama, H.; Masubuchi, H.; Yonekawa, T.; Watanabe, K.; Amino, N.; Hase, T. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000, 28, e63. [Google Scholar] [CrossRef] [Green Version]
  14. Wang, Y.; Wang, Y.; Jiao, W.; Li, J.; Quan, S.; Sun, L.; Wang, Y.; Qi, X.; Wang, X.; Shen, A. Development of loop-mediated isothermal amplification coupled with nanoparticle-based lateral flow biosensor assay for Mycoplasma pneumoniae detection. AMB Express 2019, 9, 196. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  15. Coronaviridae Study Group of the International Committee on Taxonomy of Viruses. The species Severe acute respiratory syndrome-related coronavirus: Classifying 2019-nCoV and naming it SARS-CoV-2. Nat. Microbiol. 2020, 5, 536–544. [Google Scholar] [CrossRef] [Green Version]
  16. Horiuchi, S.; Saito, Y.; Matsui, A.; Takahashi, N.; Ikeya, T.; Hoshi, E.; Shimizu, Y.; Yasuda, M. A novel loop-mediated isothermal amplification method for efficient and robust detection of EGFR mutations. Int. J. Oncol. 2020, 56, 743–749. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  17. Liu, Y.; Zhao, Y.; Qin, Y.; Du, X.; Wang, Q.; Lyu, J. A novel microfluidic device that integrates nucleic acid extraction, amplification, and detection to identify an EGFR mutation in lung cancer tissues. RSC Adv. 2016, 6, 13399–13406. [Google Scholar] [CrossRef]
  18. Jia, Z.; Yuan, H.; Zhao, X.; Yin, J.; Cong, H.; Gao, W.; Jin, Q.; Jia, C.; Zhao, J. Single-cell genetic analysis of lung tumor cells based on self-driving micro-cavity array chip. Talanta 2021, 226, 122172. [Google Scholar] [CrossRef]
  19. Chen, P.; Chen, C.; Liu, Y.; Du, W.; Feng, X.; Liu, B.-F. Fully integrated nucleic acid pretreatment, amplification, and detection on a paper chip for identifying EGFR mutations in lung cancer cells. Sens. Actuators B Chem. 2019, 283, 472–477. [Google Scholar] [CrossRef]
  20. Newton, C.; Graham, A.; Heptinstall, L.; Powell, S.; Summers, C.; Kalsheker, N.; Smith, J.; Markham, A. Analysis of any point mutation in DNA. The amplification refractory mutation system (ARMS). Nucleic Acids Res. 1989, 17, 2503–2516. [Google Scholar] [CrossRef]
  21. Benesova, L.; Pesek, M.; Belsanova, B.; Sekerka, P.; Minarik, M. Denaturing capillary electrophoresis for automated detection of L858R mutation in exon 21 of the epidermal growth factor receptor gene in prediction of the outcome of lung cancer therapy. J. Sep. Sci. 2010, 33, 2349–2355. [Google Scholar] [CrossRef] [PubMed]
  22. Pao, W.; Miller, V.; Zakowski, M.; Doherty, J.; Politi, K.; Sarkaria, I.; Singh, B.; Heelan, R.; Rusch, V.; Fulton, L. EGF receptor gene mutations are common in lung cancers from “never smokers” and are associated with sensitivity of tumors to gefitinib and erlotinib. Proc. Natl. Acad. Sci. USA 2004, 101, 13306–13311. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  23. Zeinali, M.; Lee, M.; Nadhan, A.; Mathur, A.; Huang, W.; Lin, E.; Harouaka, R.; Wicha, M.S.; Palanisamy, N.; Hafner, M. High Throughput isolation and expansion of circulating tumor cells (CTCs) from Non-small cell lung cancer (NSCLC) patients for personalized treatments. Cancer Res. 2019, 79, 1332. [Google Scholar] [CrossRef]
Figure 1. Schematic of One-Pot-LAMP for EGFR L858R decoding from genetic DNA input to result interpretation in a sealed tube.
Figure 1. Schematic of One-Pot-LAMP for EGFR L858R decoding from genetic DNA input to result interpretation in a sealed tube.
Micromachines 14 00647 g001
Figure 2. The amplification kinetic curve of One-Pot-LAMP with different variants (A) and detection result provided using electrophoresis (lane 1: M primer set with M variant, lane 2: WT primer set with WT variant, lane 3: M primer set with WT variant, lane 4: WT primer set with M variant, lane 5: M primer set with deionized water, and lane 6: WT primer set with deionized water) (B) and DNA sequencing (C).
Figure 2. The amplification kinetic curve of One-Pot-LAMP with different variants (A) and detection result provided using electrophoresis (lane 1: M primer set with M variant, lane 2: WT primer set with WT variant, lane 3: M primer set with WT variant, lane 4: WT primer set with M variant, lane 5: M primer set with deionized water, and lane 6: WT primer set with deionized water) (B) and DNA sequencing (C).
Micromachines 14 00647 g002
Figure 3. The amplification kinetic curve of One-Pot-LAMP with different concentrations of inner primer.
Figure 3. The amplification kinetic curve of One-Pot-LAMP with different concentrations of inner primer.
Micromachines 14 00647 g003
Figure 4. The amplification kinetic curve of One-Pot-LAMP under different incubation temperatures.
Figure 4. The amplification kinetic curve of One-Pot-LAMP under different incubation temperatures.
Micromachines 14 00647 g004
Figure 5. The amplification kinetic curve of One-Pot-LAMP with different proportions of target variant.
Figure 5. The amplification kinetic curve of One-Pot-LAMP with different proportions of target variant.
Micromachines 14 00647 g005
Figure 6. The amplification kinetic curve of One-Pot-LAMP with genomic DNA from cell lines.
Figure 6. The amplification kinetic curve of One-Pot-LAMP with genomic DNA from cell lines.
Micromachines 14 00647 g006
Table 1. Detection result of EGFR L858R with clinical sample.
Table 1. Detection result of EGFR L858R with clinical sample.
One-Pot-LAMPTaqMan-PCR EGFR KitAgreement
Wild TypeL858R MutationDiscrepantTotal
Wild type6006100%
L858R mutation034034100%
Total634040100%
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Liu, X.; Zhang, J.; Hua, K. Intelligent Genetic Decoding System Based on Nucleic Acid Isothermal Amplification for Non-Small Cell Lung Cancer Diagnosis. Micromachines 2023, 14, 647. https://doi.org/10.3390/mi14030647

AMA Style

Liu X, Zhang J, Hua K. Intelligent Genetic Decoding System Based on Nucleic Acid Isothermal Amplification for Non-Small Cell Lung Cancer Diagnosis. Micromachines. 2023; 14(3):647. https://doi.org/10.3390/mi14030647

Chicago/Turabian Style

Liu, Xiaonan, Jiaxing Zhang, and Kai Hua. 2023. "Intelligent Genetic Decoding System Based on Nucleic Acid Isothermal Amplification for Non-Small Cell Lung Cancer Diagnosis" Micromachines 14, no. 3: 647. https://doi.org/10.3390/mi14030647

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop