Next Article in Journal
Effects of Moisture Diffusion on a System-in-Package Module by Moisture–Thermal–Mechanical-Coupled Finite Element Modeling
Next Article in Special Issue
Low-Cost Light-Based GelMA 3D Bioprinting via Retrofitting: Manufacturability Test and Cell Culture Assessment
Previous Article in Journal
A Privacy-Preserved Internet-of-Medical-Things Scheme for Eradication and Control of Dengue Using UAV
Previous Article in Special Issue
Fabrication of Concave Microwells and Their Applications in Micro-Tissue Engineering: A Review
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A Stretching Force Control-Based Cyclic Loading Method for the Evaluation of Mechanical Properties of Gelation Methacrylate (GelMA) Microfibers

1
Intelligent Robotics Institute, School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081, China
2
Beijing Institute of Technology, Jinggong College, Beijing 100081, China
*
Author to whom correspondence should be addressed.
These authors contributed equally to this work and are both the first author.
Micromachines 2022, 13(10), 1703; https://doi.org/10.3390/mi13101703
Submission received: 25 August 2022 / Revised: 3 October 2022 / Accepted: 4 October 2022 / Published: 10 October 2022

Abstract

:
Microfluidic spun gelation mechacrylate (GelMA) microfiber has been widely utilized as a promising bioink for 3D bioprinting. However, its weak and easily tuned mechanical properties are still difficult to precisely evaluate, due to the lack of an effective stretching method. In this paper, we propose a force-control-based cyclic loading method for rapidly evaluating the elastic modulus: the E of the microfibers with different GelMA concentrations. A two-tube manipulation system is used to stretch microfiber with a non-destructive process. Based on the model reference adaptive control strategy, the stress response can be fitted into a sinusoidal wave when a small sinusoidal strain is automatically applied onto the microfiber. Afterwards, the maximum tensile stress and tensile stain is obtained to determine the E. Moreover, different stress amplitudes and frequencies are applied to form different stress-strain loops with almost same E. Compared with a frequently-used constant force loading method, the proposed method shows an obvious advantage in measurement accuracy, especially for low-concentration GelMA microfiber. Furthermore, the reasonableness of the measured E for different GelMA concentrations is confirmed by 3D cell culture experiments, and the results show the proposed method has great application potential to investigate the interaction between cell and fibrous bioink substrate.

1. Introduction

Gelatin methacryloyl (GelMA) is a gelatin derivative that can form covalently crosslinked hydrogels in the presence of a photoinitiator [1]. Low-concentration GelMA hydrogel provides a cell-favorable soft environment for the encapsulated fibroblasts, human mesenchymal stem cells, and endothelial cells, et al. [2,3]. Moreover, microfluidic spinning method enables GelMA hydrogel to be processed into GelMA hydrogel microfibers with high-throughput capability [4]. After integrating a microfluidic platform into 3D printer technology, a novel bioprinting method can be established for higher-order cell assembly to mimic in vivo tissues from vasculature to cartilage and bone [5,6,7]. For maintaining the stability of the printed structure, the mechanical properties (MP) of bioink should be modified according to accurate value measurements in advance [8,9]. Such measurements are usually implemented based on the GelMA hydrogel bulk block rather than the microfiber [10]. It is worth mentioning that the MP of GelMA hydrogel is easily tuned by the different processing conditions, such as UV exposure time, et al. Even with the same GelMA concentration and initiator concentration in the pre-gel solution, the exposure degree and time are significantly different for the laminar solution flow in the microfluidic channel and the solution in the macro-volume channel [11,12,13]. Moreover, other biopolymers can also be mixed with GelMA hydrogel to enhance the MP or promote cell growth [14,15]. Because the MP of bulk GelMA hydrogel is difficult to exactly describe the MP of the GelMA microfiber, it is necessary to independently measure the microfiber MP for subsequent evaluation of the printed structure stability and tissue maturation.
The ratio between the loading and the consequent deformation is described by the elastic modules: E to characterize the MP of GelMA hydrogel [16]. For the fiber-shaped hydrogel, the common measurement method is based on a mechanical stretcher [17,18,19]. Two ends of the microfiber are respectively fixed by two mechanical clamps, and a normal stress is applied to induce microfiber deformation. Because the loading precision is limited in dozens of micro-newton ranges, the measured microfibers usually exhibit dozens to several hundred kilopascal mechanical strength to avoid immediate tensile damage. However, previous work has shown that extremely soft environments (a few kilopascals) promote the best cellular responses, such as low-concentration GelMA [20]. For measuring the soft microfiber, a tube-tube micromanipulator system was established to provide a nano-newton actuator and sensor to handle the microfibers. In this system, two measurement strategies are provided according to two force loading modes [21,22,23,24]. One mode is based on the uniform elongation rate of the microfiber. A constant deformation speed is applied up to a tension strain beyond the break point, and E can be calculated by using the slope of the curve between the stress and strain in the linear viscoelastic range [23]. Another mode is dependent on dynamic loading. Multi-frequency stretching force loading method based on force control was developed to measure the storage and loss module: E’&E″ of multi-type microfibers [24]. However, these two modes still have some limitations in no-damage measurements for cell-laden microfibers. In the first mode, the stretching force should be continuously increased to form the curve between the stress and strain. The risk of breakage can be obviously increased, especially for microfiber with weak MP. In the second mode, because a phase shift between the applied stress and resultant strain should be measured additionally for characterizing viscoelasticity, which usually causes more than 10 min during each experiment to induce potential danger including cell pollution, dehydration, and even death [24]. Therefore, there still lacks a low-damage method to rapidly measure the E of the soft microfibers.
In this paper, we propose a cyclic loading strategy based on a two-tube manipulation system, and the small amplitude oscillatory stretch stress are automatically applied for less-damage and rapid measurement of the E of microfibers with different GelMA concentrations. The whole measuring process is shown in Figure 1. First, the corresponding relationship between the deflection of the sensing tube and stretching force: Ff is calibrated, and the effect of microscope vision on the measure result of the Ff is analyzed. Second, a scalable input adaptive control strategy is applied to allow the Ff to be consistent in each cycle loading. The strain and the resulting stress signals are fitted with sinusoidal functions with phase shifts, and then elliptical Lissajous crossplots are plotted to describe the stress-strain hysteresis loop under different Ff and frequencies. By analyzing these crossplots, we find that the precise evaluation for the E can be successfully achieved, and only depends on the minimum initial Ff rather than subsequently increasing Ff, and the whole measuring process can be finished in 5 cycles (<30 s). Moreover, we found that our proposed strategy facilitates the distinguished measurement for the E of GelMA microfibers with different concentrations, especially for low-concentration GelMA (5.5% w/v), which is difficult to achieve by traditional measuring methods based on stress-strain curve. Finally, we use further cell spreading experimentation and pore structure observation under SEM to certify the reasonableness of the measured results.

2. Materials and Methods

2.1. Microfluidic Spinning of the GelMA Microfibers

A spinning microfluidic device is composed of a coaxial needle apparatus, a transparent glass tube (length: ~5 cm, inner diameter: ~1.7 mm), and a pipette tip. The coaxial needle is inserted into one end of the glass tube, and another end of the glass tube is inserted into the pipette tip. The inserted area is sealed by an elastic adhesive tape. An amount of 1.8% w/v alginate solution and cell-laden GelMA solution are injected into the microfluidic device with the flow rate of 18 mL/h and 500 μL/h, respectively, and then a core GelMA flow surrounded by an outer alginate flow is formed in the glass tube. When the glass tube is irradiated by UV light, the GelMA flow is gelated into GelMA hydrogel microfiber, in which cells can be safely encapsulated for subsequent long-time culture [12]. The spun GelMA microfibers are ejected from the glass tube by following the ejected alginate sheath flow, and then are collected in PBS solution.

2.2. Two-Tube Micromanipulation System Setup for Stretching the Microfiber

Uniaxial stretching of the microfiber is implemented by a two-tube micromanipulation system, as shown in Figure 1. The system consists of two subsystems: an execution system and a vision system. In the execution system, a moving and a sensing tube are installed in parallel to a motorized manipulator (3 DOF) and a manual manipulator (3 DOF), respectively. Two ends of the microfiber are hung and fixed onto two tubes, and the microfiber is immersed in PBS solution. The majority of automatic manipulator components comprise three actuators (NSA12, Newport, Irvine, USA., minimum incremental motion is 0.2 μm). They are controlled by their matched controllers (NSA-PP, Newport, Irvine, USA ), which receive the command from a PC directly. The manual manipulator (LDV50-LM-C2, SELN, Dongguan, China ) is used to adjust the position of the tube and microfiber roughly. The vision system provides feedback information about the force applied on the microfiber. It comprises a stereoscopic microscopy (SZX-16, Olympus, Tokyo, Japan ) with a digital camera (DP21, Olympus, Tokyo, Japan, maximum resolution: 1600 × 1200) that is linked to a PC to capture real-time images. There is an outside light source to improve the tube’s identification by adjusting the light intensity.

2.3. Calculation of the Stretching Force Applied on the GelMA Microfiber

The fixed microfiber is axially stretched by moving the manipulating tube, and then the sensing tube can show the applied stretching force: Ff due to its easy-to-occur characteristic of small deflection deformation. The Euler–Bernoulli cantilever model is used to depict the relationship between the tube tip’s deflection utip and Ff. We can obtain:
u t i p = F f x a 2 6 E t I z ( 3 L x a )
where utip is the deflection deformation of the tube’s tip, Et is elastic modulus of the sensing tube, Iz is the moment of inertia, L is length of the tube, xa is taken as the coordinate along tube long axis of the left end as 0 and the right end as L. Because microfiber was fixed by the glue, L and xa is constant and can be measured before manipulation. We define a constant K to represent the “stiffness” of the tube. The K is confirmed from Equation (1) after microfiber is glued on the fixed position:
K = F f u t i p = 6 E I z x a 3 3 L x a 2
After that, the Ff is directly calculated by detecting the deflection deformation utip through:
F f = K u t i p

2.4. Measurement of the Microfiber’s Elastic Modulus Based on Cyclic Loading

A computer vision is utilized to provide feedback information for measuring utip. The tip is recognized from the original picture by the following machine vision processes. First, a binarization processing is utilized to segment the profile of the sensing tube from the origin pictures. The Harris corner detection algorithm is used to search the sensing tube’s tip in the whole image to obtain the coordinates of the tip, (xt, yt). Because there are many noises after binarization to disturb the result of feature point recognition, the gray morphology operation, dilate, is used to minimize the disturbance. Then, the utip is calculated by the difference between the initial position of the tube’s tip (xo, yo) and (xt, yt). Considering it is a small deflection, the deformation utip could be regarded as u t i p = x t x o directly, and the Ff is further calculated from Equation (3).
For measurement of the microfibers’ elastic modulus E, the cyclic movement of the manipulating tube is automatically implemented by control of the Ff (t) to track a time-dependent sinusoidal force signal. A model reference adaptive control (MRAC) method is proposed to improve the transient response of the controller, making the force control robust. The cross-sectional area of microfiber: S can be measured in advance, and the stress σ can be calculated by:
σ = F f S = σ 0 sin ( ω t + δ )
Meanwhile, the initial length of microfibers: Lo can be measured. The displacement of automatic manipulator: Lm can be obtained from the motorized manipulator directly, so the strain of the microfiber: ε is calculated as:
ε = L m u t i p L o = ε 0 sin ( w t + φ )
Taken together, the E is derived from Equations (4) and (5), and gives:
E = σ 0 ε 0

2.5. 3D Cell Culture in the GelMA Microfiber and cell Viability Staining

NIH/3T3 fibroblasts are harvested from a petri dish. Cell suspension is prepared by mixing fibroblasts and GelMA solution. To maintain good cell viability, GelMA should be dissolved in DMEM to form GleMA solution. For long-time 3D cell culture, cell-laden GelMA microfibers are immersed in DMEM kept at 37 °C with 5% CO2. For cell viability staining, cell-laden microfiber are immersed into 4 mL PBS solution containing 8 μL calcein-AM and 6 μL PI solution. After half an hour incubation, live and dead cells can be respectively identified by green and red points observed under inverted fluorescence microscope.

3. Results and Discussion

3.1. Accuracy Analysis for Visual-Based Evaluation of the Stretching Force

The stretching force: Ff is applied along the long axis direction of microfiber immersed in PBS solution by moving the manipulating tube away from the sensing tube, and subsequently the sensing tube is slightly bent by the stretched microfiber (Figure 2a). The bending deflection deformation is measured by the microscope to obtain the Ff. Specifically, the deflection at the tube tip: utip is proportionally converted to the Ff at some position of the sensing tube body: xa according to a spring stiffness K. Therefore, the E evaluation accuracy is affected by the theoretical calculation of K and the visual recognition for the utip.
Firstly, we used a high-precision electronic scale (JJ224BC,G&G MEASUREMENT PLANT, Changshou, China, resolution: 0.1 mg) to calibrate the K, as shown in Figure 2b. A tri-prism is placed on the horizontal surface of the scale. The sensing tube is installed on a high-precision manipulator, and its neutral axis is held parallel to the tri-prism base at the initial. When the sensing tube is descended to contact with the tri-prism tip, a point-shaped contact area is generated to mimic the contact area between the sensing tube and microfiber. We can precisely obtain the deflection: ua based on the moving distance of the manipulator and the Ff indicated by the scale. Based on Equation (2), we can obtain Equation (7) about Ka at the position from of xa:
K a = F f u a 6 E I x a 2 ( 3 x a x a )
Compared with the deflection of the ua, the utip is more clearly and easily recognized by the microscope, but it is difficult to measure in this calibration system, as shown in Figure 2b. Therefore, we further combined Equations (1) and (3) to calculate the K dependent on the Ka, as shown in Equation (8):
K = 2 x a 3 L x a K a = 2 x a 3 L x a F f u a
From Equation (8), the K responding to different xa is shown in Figure 1b, and the fitting curve was further achieved to generate the equation:
K = 6 a 213 x a 2 x a 3
in which, a is fitting parameter, and the fitting result fits well with the experimental data where the goodness of fit is 96.6%, as shown in Figure 2b. When the adhered position is fixed, the responding K can be obtained to calculate the Fr based on the: utip.
Furthermore, the utip is automatically measured by detecting the position change of the characteristic corner at the tip of the sensing tube. However, because the microscope visual feedback information is easily disturbed by the inevitable fluctuation of PBS solution, the coordinates of the recognized tip corner could fluctuate to generate a random error for the utip. To evaluate the effect of such an error on the utip, time-dependent pixel fluctuation of the tip corner is recorded, as shown in Figure 2d. Based on the Bessel equation, the standard deviation of pixel fluctuation was calculated, and its value is 2.619 pixel. Moreover, the employed microscope (DP21, Olympus, Tokyo, Japan ) has a resolution of 1600 × 1200 responding to the field of view of 7.04 mm × 5.28 mm, therefore, each pixel represents the length of 4.4 μm. Because the visual information is provided under Objective Lens (4×), therefore, the length indicated by each pixel should be further divided by 4 * 0.5 to obtain 2.2 μm. Therefore, besides the system error induced by the fitting error of the K, there is still a random error induced by the fluctuation of the tip corner to generate ±2.8809 μm for the utip. Manual manipulation for hanging microfiber allows xa to be larger than 60 mm, therefore, the visual measurement error for the Ff is usually less than 2μN, theoretically.

3.2. Design and Validation of MRAC Strategy for the Stretching Force Control

Model reference adaptive control (MRAC) is utilized to achieve force-controlled stretching for microfibers. The MRAC consists of a baseline controller and an adaptive law. The baseline controller is designed based on the mathematical microfiber model. However, the model parameters are uncertain for the microfibers with different GelMA concentrations, which can affect the performance of the baseline controller. The adaptive law is further added to compensate for these parametric uncertainties and improve the performance of the baseline controller; therefore, the Ff remains stably controlled by self-adjustment through the adaptive law [25]. The schematic block diagram of the MRAC is illustrated in Figure 3a.
The reference model of MRAC should be established first for the subsequent design of the baseline controller. The reference model is derived from the standard linear solid (SLS) model [26], as shown in Figure 3b, to depict microfiber viscoelasticity. The SLS model is composed of two elements: one is a spring and a dashpot connected in serial, and the other is an isolated spring connected in parallel. The SLS model is described as:
F = S L 0 ( K 2 + K 1 e t / ( η / k 1 ) ) u 0 = ( λ 1 + λ 2 e t / τ ) u 0
where K1, K2, η are illustrated in Figure 3a, Ff is the force applied on the microfiber, L0 is the initial length of the microfiber, S is the area of the microfiber, and u is the displacement of the manipulator, which is also equivalent to the deformation of microfiber. These parameters of Equation (6) can be fitted from the stress relaxation experiment of the microfiber.
The experiment data fitted by Equation (10) are shown in Figure 3b, and are listed in Table 1. The goodness of fit was 0.948, which meant the data was fitted well by the SLS model. In fact, we did not need to know the exact value of K1, K2, η , etc., though we can perform some mathematical operations to use the linear combinations of the τ, λ1 and λ2 to get the state space equations directly.
To control the output Ff to track the force command Fcmd, we employ the integral action [27] and define an integral state e y I t as:
e y I = F f F c m d s
where s is the Laplace integral operator. Then an augmented theoretical state space equations are defined as:
e ˙ y I x ˙ p x ˙ = 0 1 0 1 τ A e y I x p x + λ 1 + λ 2 λ 2 τ B ( u + f ) + 1 0 B r e f F c m d
e y I F f y = 1 0 0 1 C e y I x p x + 0 λ 1 + λ 2 D ( u + f )
in which, f is the parametric uncertainties.
However, the state x cannot be measured from external sensors directly, so the Luenberger observer [28] was utilized to construct the state x while we ignored f, such that:
x ˙ r o = A x r o + B u + B r e f y c m d + L ( y y r o ) y r o = C x r o + D u
in which, L is the observer gain vector and its desired value can be calculated by using Ackermann’s formula. x r o is the reference state constructed from the observer.
In addition, the baseline controller can be design from Equations (12) and (13) independently without adding the Luenberger observer according to the separation principle. To simplify the controller, we used the linear quadratic regulator (LQR) method with proportional feedback connections to design the baseline controller. We separated the input, u, into two parts as:
u = u b l + u a d = K x x r o + u a d
in which, u b l = K x x r o is the output of the baseline controller, Kx is the gain of the LQR and is chosen based on the optimal control theory.
Then we substituted Equation (15) into Equation (13) and let u a d = 0 , so the reference model can be obtained like below:
x ˙ r o = [ A L C ( B L D ) ] K x A r e f x r o + B r e f y c m d + L y y r o = ( C D K x C r e f ) x r o
The baseline controller was designed and calculated based on the reference model. However, considering the uncertainties f existed, we only estimate the value of K x (defined as K ^ x ) rather than its ideal value. The estimation error K ˜ x is defined like this:
K ˜ x = K ^ x K x
At this time, the adaptive law is designed to maintain the performance of the baseline controller by reducing the estimation error K ˜ x .
To calculate the adaptive law, the actual state space model also needs to be constructed. Similar to Equation (10), we build the actual model with the f and the actual state x ¯ like this:
x ¯ ˙ = [ A L C ( B L D ) K x A r e f ] x ¯ + B L D ( u a d K ˜ x T x ¯ + f ) + B r e f y c m d + L y y ¯ = ( C D K x C r e f ) x ¯ + D ( u a d K ˜ x T x ¯ + f )
The adaptive law is commonly designed from the Lyapunov’s direct method, so a Lyapunov’s function that contains the state error e x ( t ) = x ¯ x r o should be constructed. Before that, we calculate the first derivative of e x ( t ) , gives:
e ˙ x t = A r e f e x + B L D ( u a d K ˜ x x ¯ + f )
However, the estimation error K ˜ x and the uncertainties f are unknown, we assemble the K ˜ x x ¯ and f into a new linear combination: Θ Φ x r o = K ˜ x x ¯ + f which can be approximated by the Chebyshev polynomials. Thus the u a d was chosen as u a d = Θ ^ Φ x r o , and the estimation error of Θ ˜ is also defined as Θ ˜ = Θ ^ Θ . At this time, we consider a quadratic Lyapunov function candidate, such as:
V e x , Θ ˜ = e x P r e f e x + 2 t r Θ ˜ T Γ 1 Θ ˜ 0
where V ( e x , Θ ˜ ) is positive definite, Γ = Γ > 0 is the rates of adaptation and P r e f = P r e f > 0 is the unique symmetric positive-definite solution of the algebraic Lyapunov equation.
Time-differentiating Equation (20), gives:
V ˙ e x , Θ ˜ = e x Q r e f e x + 2 t r Θ ˜ Γ 1 Θ ˜ ˙ Φ e x P r e f B L D
Because the mechanical properties of the microfiber can be considered to stay constant or change very slowly, we can consider Θ ^ ˙ Θ ˜ ˙ . In order to ensure the stability of system during force control, V ˙ ( e x , Θ ˜ ) should be negative definite, so the adaptive law was chosen as:
Θ ^ ˙ = Γ Φ e x P r e f B L D
The force command tracking performance can be proved to be achievable because the system is bounded-input-bounded-output (BIBO).
Simulations are implemented to test the viability of the MRAC in MATLAB. The parameters used in the simulations were adopted from the stress relaxation experiments of the microfibers with different GelMA concentrations. The parameters used for simulation are listed in Table 2.
We used y c m d = 5 sin ( 2 π 0.01 t ) + 5 to mimic the cyclic loading used for testing the force command tracking ability of MRAC, and the random noise is also added to test the system’s robustness, whose mean value was 0.277 μN. The simulation results are illustrated in Figure 3c. The experiments show that the errors between the force command and the calculated output are all less than 1 μN with different GelMA concentrations. This meant the force command tracking can be well achieved by the MRAC, and it is applicable for the microfibers with different mechanical properties. Thus, the cyclic loading applied on the microfibers can be realized with the MRAC in the next experiment.

3.3. Measurement of Elastic Modulus: Ec of GelMA Microfibers

The microfiber used in this experiment is made from 7% w/v GelMA with the diameter of ~150 μm. The microfiber is stretched by moving the manipulating tube away from the sensing tube, and then the zero position of the manipulating tube is specially set when the visual feedback system begins to detect the slight increase tendency of the stretching force Ff. Afterwards, a cyclic loading is implemented by making the Ff varied, followed with a preset sinusoidal force signal: Fcmd. Although the variation and frequency of the Ff signal almost keeps consistent with the preset signal, there is an obvious phase delay between them. In addition, considering that the Ff signal is directly converted from the utip, ambient noise is inevitably present to induce signal fluctuation, as shown in Figure 4a. Fluctuation-induced signal error is periodically generated for different amplitudes and frequencies, as shown in Figure 4b,c, respectively.
Because utip (~10 μm) is much smaller than the moving distance of the manipulating tube (several hundred micrometers), microfiber strain along its long axis direction could be considered to be same with the displacement data provided by the motorized manipulator. The response of the microfiber strain to the stretching stress is depicted by the scatter plot, as shown in Figure 5a. We find the distribution of these data points has an elliptic form. Furthermore, we fit both the stress and stain signals with sinusoidal functions with phase shifts, and Lissajous curve is established from the fitted signals to describe the stress-strain loop, as shown in Figure 5a. The Lissajous curves consist of plots of the intracycle periodic stress normalized for stress amplitude, plotted against the strain date normalized for strain amplitude, and the curves are elliptical in the linear viscoelastic region. According to small-amplitude oscillatory shear theory, the elastic modulus Ec is the ratio of maximum stress and maximum strain. Corresponding to the Lissajous crossplot, we use the crossover point A to substitute the point B responding to the maximum strain to calculate the: Ec because of the relatively large ratio of the long and short axis of the resulting ellipse. The long axis of the ellipse can project to the x and y axis to form the length: Lx and Ly, and the Ec can be directly calculated by the ratio of Ly to Lx. Furthermore, we use different Ff to cyclically stretch the microfiber under the same frequency to form different elliptical stress-strain loops. The values of the measured Ec are almost the same for different Ff, and even further for different frequency with the same Ff, as shown in Figure 5b,c. Higher frequency induces a larger area of the loop indicating higher energy dissipation.
To verify the reasonableness of such cyclic measurement results, we further used a traditional constant force loading method to measure the Ecf as the control group. We set the velocity of the manipulating tube at 10 mm/min, and continuously increase the stretching force: Fcf to the respected values, as shown in Figure 5d. The stretching process is sampled with a time interval of 0.2 s to establish the stress-strain scatter plot. The stress-strain changing trends are almost consistent for four different Fcf, and the viscoelasticity-induced delay between the stress and strain is clearly observed at the initial and final phase of the stretching process. Differing from the ellipse-shaped phase lag, a horizontal and vertical line-shaped phase lag is formed because of the lack of unloading process. When the stretched microfiber begins to be elongated at the initial phase, the Fcf has a delay in being transmitted from the microfiber to the sensing tube. Similarly, the Fcf still increases when the manipulating tube has stopped to stretch the microfiber at the final phase. We use a linear equation to fit the stress and strain, and the resulting Ecf is the same as the Es measured in the cyclic loading, as shown in Figure 5d. Such a similarity shows the increased Fcf could be substituted by a small and constant Ff to achieve the E measurement. Moreover, practical experience shows the measurement can be simply achieved as long as the Ff is sensed by the sensing tube, though it is time-consuming to get enough data to form a linear stress-strain curve whose slope is available to be utilized to calculate the E.

3.4. Evaluation of Measurement Reasonableness Based on Cell Response in 3D

Based on the same microfluidic spinning condition, NIH/3T3 fibroblasts are respectively encapsulated into 5.5% and 8.5% w/v GelMA microfibers for 3D cell culture. At initial phase, high cell viability is shown in both microfibers because of the mild spinning environment. After 10 days of culture, cells randomly spread in 5.5% GelMA microfibers, while cell aggregations generated in 8.5% w/v GelMA microfibers, as shown in Figure 6a. Because high GelMA concentration can provide sufficient cell adhesion sites for cell spreading, we conjecture that such aggregation behavior is not induced by lack of cell adhesion sites as in alginate microfiber [29], which is also proved by a cellular layer that is stably formed on the surface of 8.5% w/v GelMA microfiber. For the same initiator concentration and spinning conditions, the average pore sizes in GelMA hydrogel are inversely related to the concentration of GelMA, and mechanical properties can be correspondingly tuned for the resulting GelMA microfiber [9]. Therefore, we consider that different cell morphologies are also related to tuned mechanical properties.
Figure 6c shows the average values of the measured Ec and Ecf of two microfibers under a cyclic and constant force loading method, respectively. The Ec for different concentrations can be distinguished under cyclic loading. Such measurement results are well corresponding to cell responses in two GelMA microfibers. High Ec for 8.5% w/v GelMA concentration indicated dense pore size distribution to form high density of cell adhesion site to prevent from cell spreading, while relatively large pores with the low site density allow cell spreading in 5.5% w/v GelMA microfiber with low Ec. Cell response on the microfiber is almost consistent with the bulk hydrogel with the same GelMA concentration. According to the standard data measured from the bulk hydrogel (Suzhou Intelligent Manufacturing Research Institute, Suzhou, China), the E of 5% and 10% w/v GelMA hydrogels are 16.63 and 61.84 kPa, respectively, but the Ec of microfibers for 5.5% and 8.5% w/v are less than 10 kPa even though material-related parameters are identical. Therefore, there is an obvious difference for the E between hydrogel microfiber and bulk hydrogel, and such a difference may be induced by the exposure time. Furthermore, for constant force loading, Ecf for 5.5% w/v is obviously smaller than 7% w/v. We further analyze the reason for such obvious differences, as shown in Figure 6c. We found the Ecf-indicated slope of the fitted curve is strongly related to sample size. The five samples may be gathered in both the linear and non-linear viscoelastic ranges. Therefore, when the curve is fitted dependent on the five samples (black line), the samples in the non-linear range obviously enable the slope to be reduced. Moreover, Ecf can increase when only three previous samples are utilized to be fitted (red line), while Ecf is larger than that for 8.5% w/v according to the curve fitted by the previous two samples (blue line). This above-mentioned result further shows the cyclic loading method can provide a sensitive approach to precisely measure the E of microfibers. Because a weaker stretching force is required in the cyclic method relative to the traditional method, and the force-induced deformation in a time-dependent manner could be reduced to further suppress the measurement error to facilitate precise measurements. In addition, our proposed method can also be used to investigate microfiber viscoelasticity because of dynamic loading process, and viscoelastic behaviors are critical for re-establishment of cell microenvironment [30,31].

4. Conclusions

Elastic modulus: E is a basic indicator to describe the mechanical complexity of biological tissue. We propose a force-controlled cyclic stretching method to evaluate the E of the GelMA microfibers with characteristics of high stability, high precision and low-damage. Therefore, our proposed method can promote the investigation of the effect of mechanical properties on cell behaviors, the study of interaction between cells and substrate, and microfiber material design for 3D bioprinting.

Author Contributions

Conceptualization, Q.L.; methodology, Q.L.; software, X.Y.; validation, X.Y.; formal analysis, T.S.; investigation, T.S.; resources, T.S.; data curation, X.C.; writing—original draft preparation, T.S.; writing—review and editing, Q.H.; supervision, T.S.; project administration, T.S.; funding acquisition, T.S. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by National Natural Science Foundation of China under grant number 62173043.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Klotz, B.J.; Gawlitta, D.; Rosenberg, A.J.W.P.; Malda, J.; Melchels, F.P.W. Gelatin-methacryloyl hydrogels: Towards biofabrication-based tissue repair. Trends Biotechnol. 2016, 34, 394–407. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Nichol, J.W.; Koshy, S.T.; Bae, H.; Hwang, C.M.; Yamanlar, S.; Khademhosseini, A. Cell-laden microengineered gelatin methacrylate hydrogels. Biomaterials 2010, 31, 5536–5544. [Google Scholar] [CrossRef] [Green Version]
  3. Wei, Z.; Sun, T.; Shimoda, S.; Chen, Z.; Chen, X.; Wang, H.; Huang, Q.; Fukuda, T.; Shi, Q. Bio-inspired engineering of a perfusion culture platform for guided three-dimensional nerve cell growth and differentiation. Lab Chip 2022, 22, 1006–1017. [Google Scholar] [CrossRef]
  4. Shao, L.; Gao, Q.; Zhao, H.; Xie, C.; Fu, J.; Liu, Z.; Xiang, M.; He, Y. Fiber-Based Mini Tissue with Morphology-Controllable GelMA Microfibers. Small 2018, 14, 1802187. [Google Scholar] [CrossRef]
  5. Colosi, C.; Shin, S.R.; Manoharan, V.; Massa, S.; Costantini, M.; Barbetta, A.; Dokmeci, M.R.; Dentini, M.; Khademhosseini, A. Microfluidic bioprinting of heterogeneous 3D tissue constructs using low-viscosity bioink. Adv. Mater. 2016, 28, 677–684. [Google Scholar] [CrossRef] [Green Version]
  6. Liu, W.; Zhong, Z.; Hu, N.; Zhou, Y.; Maggio, L.; Miri, A.K.; Fragasso, A.; Jin, X.; Khademhosseini, A.; Zhan, Y.S. Coaxial extrusion bioprinting of 3D microfibrous constructs with cell favorable gelatin methacryloyl microenvironments. Biofabrication 2018, 10, 024102. [Google Scholar] [CrossRef] [PubMed]
  7. Costantini, M.; Colosi, C.; Święszkowski, W.; Barbetta, A. Co-axial wet-spinning in 3D bioprinting: State of the art and future perspective of microfluidic integration. Biofabrication 2019, 11, 012001. [Google Scholar] [CrossRef]
  8. Zuo, Y.; He, X.; Yang, Y.; Wei, D.; Sun, J.; Zhong, M.; Xie, R.; Fan, H.; Zhang, X. Microfluidic-based generation of functional microfibers for biomimetic complex tissue construction. Acta Biomater. 2016, 38, 153–162. [Google Scholar] [CrossRef] [PubMed]
  9. Yin, J.; Yan, M.; Wang, Y.; Fu, J.; Suo, H. 3D bioprinting of low-concentration cell-laden gelatin methacrylate (GelMA) bioinks with a two-step cross-linking strategy. ACS Appl. Mater. Interfaces 2018, 10, 6849–6857. [Google Scholar] [CrossRef]
  10. Costantini, M.; Testa, S.; Fornetti, E.; Barbetta, A.; Trombetta, M.; Cannata, S.M.; Gargioli, C.; Rainer, A. Engineering Muscle networks in 3D gelatin Methacryloyl hydrogels: Influence of Mechanical stiffness and geometrical confinement. Front. Bioeng. Biotechnol. 2017, 5, 22. [Google Scholar] [CrossRef] [PubMed]
  11. Yue, K.; Trujillo-de Santiago, G.; Alvarez, M.M.; Tamayol, A.; Annabi, N.; Khademhosseini, A. Synthesis, properties, and biomedical applications of gelatin methacryloyl (GelMA) hydrogels. Biomaterials 2015, 73, 254–271. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  12. Sun, T.; Shi, Q.; Liang, Q.; Yao, Y.; Wang, H.; Sun, J.; Huang, Q.; Fukuda, T. Fabrication of vascular smooth muscle-like tissues based on self-organization of circumferentially aligned cells in microengineered hydrogels. Lab A Chip 2020, 20, 3120–3131. [Google Scholar] [CrossRef]
  13. Chansoria, P.; Asif, S.; Polkoff, K.; Chung, J.; Piedrahita, J.A.; Shirwaiker, R.A. Characterizing the Effects of Synergistic Thermal and Photo-Cross-Linking during Biofabrication on the Structural and Functional Properties of Gelatin Methacryloyl (GelMA) Hydrogels. ACS Biomater. Sci. Eng. 2021, 7, 5175–5188. [Google Scholar] [CrossRef] [PubMed]
  14. Liang, Q.; Gao, F.; Zeng, Z.; Yang, J.; Wu, M.; Gao, C.; Cheng, D.; Pan, H.; Liu, W.; Ruan, C. Coaxial Scale-Up Printing of Diameter-Tunable Biohybrid Hydrogel Microtubes with High Strength, Perfusability, and Endothelialization. Adv. Funct. Mater. 2020, 30, 2001485. [Google Scholar] [CrossRef]
  15. Samandari, M.; Alipanah, F.; Majidzadeh-A, K.; Alvarez, M.M.; Trujillo-de Santiago, G.; Tamayol, A. Controlling cellular organization in bioprinting through designed 3D microcompartmentalization. Appl. Phys. Rev. 2021, 8, 021404. [Google Scholar] [CrossRef]
  16. Guimarães, C.F.; Gasperini, L.; Marques, A.P.; Reis, R.L. The stiffness of living tissues and its implications for tissue engineering. Nat. Rev. Mater. 2020, 5, 351–370. [Google Scholar] [CrossRef]
  17. Cuadros, T.R.; Skurtys, O.; Aguilera, J.M. Mechanical properties of calcium alginate fibers produced with a microfluidic device. Carbohydr. Polym. 2012, 89, 1198–1206. [Google Scholar] [CrossRef]
  18. Wei, D.; Charlton, L.; Glidle, A.; Qi, N.; Dobson, P.S.; Dalby, M.J.; Fan, H.; Yin, H. Dynamically Modulated Core−Shell Microfibers to Study the Effect of Depth Sensing of Matrix Stiffness on Stem Cell Fate. ACS Appl. Mater. Interfaces 2021, 13, 37997–38006. [Google Scholar] [CrossRef]
  19. Gaharwar, A.K.; Schexnailder, P.J.; Dundigalla, A.; White, J.D.; Matos-Pe´rez, C.R.; Cloud, J.L.; Seifert, S.; Wilker, J.J.; Schmidt, G. Highly Extensible Bio-Nanocomposite Fibers. Macromol. Rapid Commun. 2011, 32, 50–57. [Google Scholar] [CrossRef]
  20. Akiyama, Y. Design of Temperature-Responsive Cell Culture Surfaces for Cell Sheet Engineering. Cyborg Bionic Syst. 2021, 2021, 5738457. [Google Scholar] [CrossRef]
  21. Kim, H.; Kim, M.-C.; Asada, H.H. Extracellular matrix remodeling induced by alternating electrical and mechanical stimulations increases the contraction of engineered skeletal muscle tissues. Sci. Rep. 2019, 9, 2732. [Google Scholar] [CrossRef] [PubMed]
  22. Akiyama, Y.; Nakayama, A.; Nakano, S.; Amiya, R.; Hirose, J. An Electrical Stimulation Culture System for Daily Maintenance-Free Muscle Tissue Production. Cyborg Bionic Syst. 2021, 2021, 9820505. [Google Scholar] [CrossRef]
  23. Onoe, H.; Okitsu, T.; Itou, A.; Kato-Negishi, M.; Gojo, R.; Kiriya, D.; Sato, K.; Miura, S.; Iwanaga, S.; Kuribayashi-Shigetomi, K.; et al. Metre-long cell-laden microfibres exhibit tissue morphologies and functions. Nat. Mater. 2013, 12, 584–590. [Google Scholar] [CrossRef]
  24. Chen, X.; Sun, T.; Wei, Z.; Chen, Z.; Wang, H.; Huang, Q.; Fukuda, T.; Shi, Q. A clamp-free micro-stretching system for evaluating the viscoelastic response of cell-laden microfibers. Biosens. Bioelectron. 2022, 214, 114517. [Google Scholar] [CrossRef]
  25. Nguyen, N.T. Model-Reference Adaptive Control. In Model-Reference Adaptive Control: A Primer; Springer International Publishing: Cham, Switzerland, 2018; pp. 83–123. [Google Scholar]
  26. Marques, S.P.C.; Creus, G.J. Rheological Models: Integral and Differential Representations. In Computational Viscoelasticity; Springer: Berlin/Heidelberg, Germany, 2012; pp. 11–21. [Google Scholar]
  27. Menner, M.; Annaswamy, A.M.; Holzapfel, F. Robust Design of Adaptive Output Feedback Controllers for Direct Feedthrough Systems. J. Guid. Control. Dyn. 2018, 41, 1919–1928. [Google Scholar] [CrossRef]
  28. Zhang, C.; Zhang, Y.; Wang, W.; Xi, N.; Liu, L. A Manta Ray-Inspired Biosyncretic Robot with Stable Controllability by Dynamic Electric Stimulation. Cyborg Bionic Syst. 2022, 2022, 9891380. [Google Scholar] [CrossRef]
  29. Lee, K.Y.; Mooney, D.J. Alginate: Properties and biomedical applications. Prog. Polym. Sci. 2012, 37, 106–126. [Google Scholar] [CrossRef] [Green Version]
  30. Chaudhuri, O.; Cooper-White, J.; Janmey, P.A.; Mooney, D.J.; Shenoy, V.B. Effects of extracellular matrix viscoelasticity on cellular behaviour. Nature 2020, 584, 535–546. [Google Scholar] [CrossRef]
  31. Ma, Y.; Han, T.; Yang, Q.; Wang, J.; Feng, B.; Jia, Y.; Wei, Z.; Xu, F. Viscoelastic Cell Microenvironment: Hydrogel-Based Strategy for Recapitulating Dynamic ECM Mechanics. Adv. Funct. Mater. 2021, 14, 2100848. [Google Scholar] [CrossRef]
Figure 1. Measurement process. Cell-laden GelMA microfibers are first spun by microfluidic device, and the tow-tube micromanipulation system is utilized to measure the microfiber E.
Figure 1. Measurement process. Cell-laden GelMA microfibers are first spun by microfluidic device, and the tow-tube micromanipulation system is utilized to measure the microfiber E.
Micromachines 13 01703 g001
Figure 2. Measuring accuracy analysis of the sensing tube-indicated stretching force. (a) Schematic of two−tube stretching manipulation. (b) Calibration of the stiffness: K of the sensing tube. (c) Process of the sensing tube’s tip recognition to measure the utip. (d) Pixel fluctuation process of the tip.
Figure 2. Measuring accuracy analysis of the sensing tube-indicated stretching force. (a) Schematic of two−tube stretching manipulation. (b) Calibration of the stiffness: K of the sensing tube. (c) Process of the sensing tube’s tip recognition to measure the utip. (d) Pixel fluctuation process of the tip.
Micromachines 13 01703 g002
Figure 3. The stretching force control strategy. (a) Block diagram of the proposed MRAC method. (b) Experimental data fitted with SLS model based on 7% w/v GelMA microfiber. (c) Simulation results of MRAC with microfiber with 7% and 5.5% w/v GelMA microfiber.
Figure 3. The stretching force control strategy. (a) Block diagram of the proposed MRAC method. (b) Experimental data fitted with SLS model based on 7% w/v GelMA microfiber. (c) Simulation results of MRAC with microfiber with 7% and 5.5% w/v GelMA microfiber.
Micromachines 13 01703 g003
Figure 4. Tracking performance evaluation. (a) Time series of Ff vs. Fcmd (b) Time series of sine wave tracking error with different stress amplitudes. (c) Time series of sine wave tracking error with different frequencies.
Figure 4. Tracking performance evaluation. (a) Time series of Ff vs. Fcmd (b) Time series of sine wave tracking error with different stress amplitudes. (c) Time series of sine wave tracking error with different frequencies.
Micromachines 13 01703 g004
Figure 5. Analysis of stress-strain relationship. (a) Scatter plot from the original signals and elliptical Lissajous crossplot from the fitted signals to describe stress-strain loop. (b) Elliptical Lissajous crossplots under different stress amplitudes. (c) Elliptical Lissajous crossplots under different frequencies. (d) Stress-strain curve under different constant force loading. Insert is a time-dependent constant force control.
Figure 5. Analysis of stress-strain relationship. (a) Scatter plot from the original signals and elliptical Lissajous crossplot from the fitted signals to describe stress-strain loop. (b) Elliptical Lissajous crossplots under different stress amplitudes. (c) Elliptical Lissajous crossplots under different frequencies. (d) Stress-strain curve under different constant force loading. Insert is a time-dependent constant force control.
Micromachines 13 01703 g005
Figure 6. Reasonableness verification of E measurement. (a,b) Cell growth in 5.5% and 8.5% w/v GelMA microfibers, respectively. (Images of bright field, fluorescence for indicating live/dead cell, SEM for showing porous structure from top to bottom). (c) Ec for cyclic force loading vs. Ecf for constant force loading. (d) Stress-strain curves fitted from previous two (blue), three (red) sample data and whole sample data (black).
Figure 6. Reasonableness verification of E measurement. (a,b) Cell growth in 5.5% and 8.5% w/v GelMA microfibers, respectively. (Images of bright field, fluorescence for indicating live/dead cell, SEM for showing porous structure from top to bottom). (c) Ec for cyclic force loading vs. Ecf for constant force loading. (d) Stress-strain curves fitted from previous two (blue), three (red) sample data and whole sample data (black).
Micromachines 13 01703 g006
Table 1. Fitted result by SLS model.
Table 1. Fitted result by SLS model.
Parameter λ 1 λ 2 τ u Goodness of Fit: R2
value11.230.762944.9490.948
Table 2. Fitted results of GelMA microfiber with different concentrations.
Table 2. Fitted results of GelMA microfiber with different concentrations.
Parameter λ 1 λ 2 τ
7% w/v GelMA11.230.762944.94
5.5% w/v GelMA30.723.58456.20
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Liang, Q.; Yu, X.; Chen, X.; Huang, Q.; Sun, T. A Stretching Force Control-Based Cyclic Loading Method for the Evaluation of Mechanical Properties of Gelation Methacrylate (GelMA) Microfibers. Micromachines 2022, 13, 1703. https://doi.org/10.3390/mi13101703

AMA Style

Liang Q, Yu X, Chen X, Huang Q, Sun T. A Stretching Force Control-Based Cyclic Loading Method for the Evaluation of Mechanical Properties of Gelation Methacrylate (GelMA) Microfibers. Micromachines. 2022; 13(10):1703. https://doi.org/10.3390/mi13101703

Chicago/Turabian Style

Liang, Qian, Xiao Yu, Xie Chen, Qiang Huang, and Tao Sun. 2022. "A Stretching Force Control-Based Cyclic Loading Method for the Evaluation of Mechanical Properties of Gelation Methacrylate (GelMA) Microfibers" Micromachines 13, no. 10: 1703. https://doi.org/10.3390/mi13101703

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop