Article

Numerical Simulation of Damage Evolution and Electrode Deformation of X100 Pipeline Steel during Crevice Corrosion

School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
*
Author to whom correspondence should be addressed.
Materials 2022, 15(6), 2329; https://doi.org/10.3390/ma15062329
Submission received: 7 February 2022 / Revised: 15 March 2022 / Accepted: 18 March 2022 / Published: 21 March 2022

Abstract

:
In this paper, the spatial and temporal damage evolution was described during crevice corrosion through developing a two-dimensional (2-D) model. COMSOL code was used to simulate the crevice corrosion regulated by the I∙R voltage of nickel (Ni) metal in sulfuric acidic. The electrode deformation, potential and current curves, and other typical characteristics were predicted during crevice corrosion, where results were consistent with published experimental results. Then, based on the Ni model, the damage evolution of X100 crevice corrosion in CO2 solution was simulated, assuming uniform distribution of solution inside and outside the crevice. The results showed that over time, the surface damage of Ni electrode increased under a constant applied potential. As the gap increased, the critical point of corrosion (CPC) inside the crevice moved into a deeper location, and the corrosion damage area (CDA) gradually expanded, but the threshold value of corrosion damage remained almost unchanged. The CDA inside the crevice extended toward the opening and the tip of crevice. Since the potential drop in this region increases with increasing current, the passivation potential point moved towards the opening. As the gap increased and the electrolyte resistance decreased, the critical potential for reaching the maximum corrosion rate moved into a deeper location. It is significant for predicting the initial damage location and the occurrence time of surface damage of crevice corrosion through the 2-D model that is not available through the one-dimensional simplified model.

1. Introduction

Characterized by high strength, high toughness, low buckling ratio, and good corrosion resistance, X100 is widely used in oil and natural gas transportation. With the development of CO2 mixed flooding technology (CO2–EOR) in oil and gas exploitation, the existence of CO2 gas in the pipelines is inevitable. The dissolved CO2 forms carbonate or bicarbonate solution, which causes corrosion of the pipelines [1,2]. In metal-insulator or metal-metal gaps, metal dissolution and limited mass-transport effect inside the crevice lead to acidification of solution internal the gap, where Cl migration keeps the solution electroneutral. With the increase of metal dissolution rate, hydrolytic reactions in the inner crevice and ionic mobility into the crevice both increase, inducing an accelerated corrosion rate. Due to the non-uniform distribution of metal ions and dissolved gases inside and outside the crevice, this leads to a potential difference (PD) in the corrosion solution to affect the kinetics of the electrode process and even establishes an electrochemical cell [3,4,5]. Corrosion behavior of thermal barrier coatings (TBCs) in molten salt at high temperature is similar with crevice corrosion. The TBCs are mainly used in critical components of aircraft gas turbine engines [6,7,8]. The corrosion of coating-molten salt-gas systems is formed at high temperatures, which is similar to the insulation–solution–metal crevice corrosion system, but the corrosion mechanism is different [9,10]. According to a large number of detailed descriptions and studies on the corrosion behavior of TBCs by Yasin, Kadir, and Abdullah et al., it can be seen that the corrosion of TBCS is the cumulative effect of the chemical impurity of molten salts such as vanadium oxide (V2O5) and sodium sulfate (Na2SO4) on the coating–gas interface during 1000 °C combustion [11,12,13].
The corrosion deposition will gradually accumulate and block the crevice opening, so the crevice corrosion is generally invisible and quite dangerous [14,15,16]. Almost all metals and alloys are subject to crevice corrosion, but the sensitivity of metal to corrosive media is different. Metal and alloys with self-passivation properties (stainless steel, aluminum alloys, titanium alloys) are more susceptible to crevice corrosion in aerated neutral media with reactive anions [17,18,19]. The sensitivity of metal to crevice corrosion depends on its self-passivation ability. Some elements of Cr, Ni, Mo, N, Cu, and Si can effectively improve the corrosion resistance of stainless steel [20,21,22].
The electrode potential theory (EPT), that is, the I∙R theory proposed by Pickering, indicates that the first stage is O2 depletion followed by depolarization of Ni, causing transfer of the cathodic reaction to the exposed surface of Ni metal in solution. The PD between the exposed surface and the gap creates a coupling potential due to the depolarization effect. Because of restrained diffusion transfer, the cathodic reaction only occurs on the boldly exposed surface outside the crevice. The combination of the anode area inside the crevice and the cathode area outside the crevice forms an electrolyte current channel. Assuming that the electrolyte resistance in the flow channel is R, the current I through the channel will produce a PD of Δφ* = I∙R voltage drop inside and outside the crevice, which is the driving force that induces the transformation of metal or alloy material from passivity to activity and crevice corrosion. PD as a function of crevice depth contributes to the initiation of crevice corrosion in metals with an active-to-passive transition in Pickering’s model [23,24,25,26].
Theoretical models of crevice corrosion have been studied extensively. Abdulsalam [27] developed a model for Ni crevice corrosion and studied the effect of different potentials on corrosion rate based on Ni anodic polarization curves. Kennell [28] proposed a one-dimensional steady-state model of crevice corrosion combining the critical crevice solution theory (CCST) and the I∙R drop theory, which can calculate the variation of electrolyte composition concentration over time and the distribution of local corrosion current and can simulate the corresponding potential evolution according to the three processes of crevice corrosion. Xu and Song [29,30] developed a mathematical model for predicting the chemistry pipeline for variable crevices (i.e., crevice width varies with length) and explored the changes in chemical reactions and corrosion rates in pipeline surfaces with/without cathodic protection. Stenta and Kahyarian [31,32] established a one-dimensional crevice corrosion model under cathodic protection conditions to study transient electrochemical corrosion processes. Most of the aforementioned models consider only one dimension of the crevice corrosion (the effect of the crevice width on the potential and chemical parameters are ignored).
In this paper, a 2-D crevice corrosion of Ni metal in acidic electrolyte was modeled for simulating the corrosion damage evolution of Ni under different potentials and crevice widths by using COMSOL code. The initial location of corrosion damage, electrode surface deformation, interface potential distribution, and corrosion current density distribution were discerned, and the simulation and experiment were compared to provide a basis for crevice corrosion controlled by I∙R voltage drop. Further, based on the damage model of Ni crevice corrosion, the electrode deformation of X100 crevice corrosion in a solution containing CO2 was studied, and different factors on the corrosion rate were investigated.

2. Simulation of Ni Electrode Crevice Corrosion

The process of using the Finite Element Software COMSOL with the corrosion module to compute the crevice corrosion of Ni electrode mainly includes the following steps:
(1) Model Definition: The “corrosion, secondary interface” is used to model the problem. A 2-D model was built based on the actual gap size, consisting of a piece of metal and a piece of insulator. The depth of the gap was 10 mm, and the width was set to 0.1~0.3 mm. The change of electrolyte concentration along the width of the gap was ignored. The cell geometry was modeled by including the crevice and a 2-mm square outside the crevice mouth. An electrolyte region was used to model electrolyte charge transport.
(2) Boundary conditions: an Electrode Surface boundary node was added to model electrode surface deformation. The experimental polarization data for the electrode reaction kinetics were used as an interpolation polynomial. The potential of the electrode was set to 0.3 V. An Electrolyte Potential boundary condition was used to apply a 0 V electrolyte potential along the leftmost boundary. The default Insulation condition was used for all other boundaries. For the deformed geometry, on the nonmoving boundaries, the model was solved with the default Nondeforming Boundary. These boundaries were all straight lines, so to improve the shape of the deformation in the corners of the geometry, and also to reduce the problem size, the boundary condition setting of the feature was changed to Zero Normal Displacement.
(3) Meshing: a higher resolution mesh at the crevice mouth was built, and the maximum element size was 8 × 10−4 mm, the minimum element size was 3 × 10−6 mm, and the maximum element growth rate was 1.3. After the local mesh of keys area was refined, the maximum element size was 1.2 × 10−4 mm, the minimum size was 2.4 × 10−7 mm, and the maximum element growth rate was 1.1.
(4) Solving: the problem was solved using a Time Dependent with Initialization study. The study contains two solver steps: a Current-Initialization step first solves for the potentials only, using a stationary solver. The second Time-Dependent step solves for the full problem for the prescribed 50 h duration. The change curve of electrolyte potential and deformation geometry was plotted; the corrosion current density distribution along the electrode surface at different times was plotted; and the potential difference distribution between the potential in the electrode and the electrolyte potential along the nickel surface was plotted.
(5) Convergence test: We refined the meshes of the key areas of the model and compared the calculation results before and after refinement. When the results did not change substantially but converged to a certain value, we considered the mesh to have converged and no further refinement was required.

2.1. Geometric Model

A 2-D model of the crevice consisting of epoxy resin (insulator) to contact with Ni metal vertically is presented in Figure 1. One side of the Ni metal is in a narrow channel, and the other is exposed to the electrolyte, forming an occlusion region. The internal electrolyte of the crevice, marked as Part I, is oriented with the origin at the crevice opening. The x-direction is positive from the opening toward the crevice tip. The y-positive direction is from the crevice bottom upwards. Part II defines the external electrolyte region. In Part I, the width of the crevice is defined by W, and the depth along the x-direction is defined by L, respectively. In Part II, the width of the electrolyte region outside is denoted by M and the width of the exposed surface area is denoted by N.

2.2. Potential Boundary Conditions

The polarization curve for a planar Ni electrode is shown in Figure 2. The polarization curve includes two regions: one is the active region, where the current density increases with the increased anodic polarization, and the other is the passive region, where the current density decreases or remains constant with the increased polarization. The electrolyte of pH = 0.3 and 0.5 mol/L H2SO4 at 24 °C was used to model the electrolyte charge transport, with a conductivity of k = 0.184 S/cm, assuming that the properties (concentration, pH value, conductivity, etc.) of the electrolyte inside the crevice remained constant. Ni metal surface contacted the electrolyte solution as an anode. The corrosion current density was expected to be adequately small to ignore the convective mass transfer and electrolyte solution diffusion effect; only the mass transfer of electromigration and the current generated by ion electromigration were considered. As the anode current flowed from inside the gap through the electrolyte to the uncovered metal surface, an ohmic voltage drop occurred along the length of the gap. The magnitude of this potential drop at the transition location from active potential to passive potential is given by Ohm’s law, Δφ* = I∙R, when the transition occurs between the active state and the passive state of the Ni surface, where I is equal to icrit multiplied by the surface area of the crevice, icrit is the critical current density when the transition occurs between the active state and the passive state, and R is the resistance of the electrolyte solution inside the crevice, given by Formula (1):
R = ρ x A
where, ρ denotes the electrolyte resistivity inside the crevice. x is the location along the crevice depth. A is the cross-sectional area of the crevice opening.
The potential boundary conditions (PBCs) of this 2-D model include the insulation PBCs, electrolyte solution PBCs, and electrode deformation PBCs. The boundary conditions of Part I and Part II are shown in Figure 3a,b, respectively.
Crevice interior, Part I, boundary conditions: Because the epoxy resin is an insulator,
E x = 0 , x = L E y = 0 , y = W
The PBC of electrolyte solution at the crevice opening is prescribed,
E = E B , x = 0
where, EB is an unknown parameter, used to match the potential of Part I with Part II in the crevice opening.
The corrosion damage y = H(x, t) on the Ni interface is due to the dissolution of Ni. The electrode deformation PBCs are determined by Ohm’s law:
k E n ^ = i E = x W + H K E x
where, k denotes electrical conductivity, and n ^ is defined as the unit normal vector to the Ni outward surface. Then, i(E) denotes the current density of the polarization profile in Figure 2. Without the damage evolution, that is H = 0, and assumptions of a constant current density, i. Formula (4) widens those applications to the damage evolution of a metal surface considering the temporal and spatial variation of current density in the gap. Due to the nonlinearity of the polarization curve i(E) and the H(x, t) with a free boundary, the equation displays as highly nonlinear.
Crevice exterior, Part II, boundary conditions: the boundary x = −M and y = −N + W of the contact between the electrolyte solution and Ni surface were much larger than the crevice width W, so the insulation condition could be maintained in the far field of the electrolyte solution:
E x = 0 , x = M E y = 0 , y = N + W
Along the boundary x = 0, a piecewise constant function of the electrolyte solution area is defined, 0 ≤ yW, and the exposed surface is defined by −N + Wy < 0,
E 0 , y = E B , y 0 E A , y < 0
where, EA is the potential value of the exposed surface of Ni metal in the electrolyte solution, and EB is the unknown potential at the opening. Since the potential on the exposed surface is artificially specified, it is not necessary to model the reduction reaction on the cathode surface.

2.3. Damage Equations

Assuming that the electrolyte in Part I and Part II is uniform, the potential E in the system is controlled by the Laplace equation:
2 E = 0
The polarization curve between the current density i(E) and the potential E in Figure 2 may be expressed as follows [34]:
i ( E ) = 1.177495 tanh 0.1 E + 12 + 1.177505 , E 0.0072 1.956848 + 0.022120 x + 0.000845 x 2 + 0.000006 x 3 , 0.072 < E 0.016 2.046685 + 0.030218 x + 0.000804 x 2 0.000006 x 3 , 0.016 < E 0.108 3.675890 tanh ( 0.08 x 12.8 ) + 3.675900 , E > 0.108
Once E is determined, electrolysis was used to correlate the rate of metal dissolution, correlated with the current density by Faraday Electrolysis Law, and i(E) was used to define the space and time evolution H(x, t) of the corrosion damage profile in Figure 2. The damage evolution formula in Ref. [34] is
H t 1 + H x 2 1 / 2 = i E M N i 2 F ρ N i
where the left of Equation (10) represents the normal velocity of the damaged front, MNi is the molecular weight of Ni, the exponential factor 2 in the right denominator represents the oxidation state of the species, F is Faraday’s constant, and ρNi is the density of Ni. Initially, there was no corrosion damage, so H(x, 0) = 0.
H t = i ( E ) M N i 2 F ρ N i H ( x , 0 ) = 0
This is a free-boundary damage problem for the metal surface, H(x, t), and its shape can be derived from the solution of Equation (9). The Laplace Equation (7) in the combination Part I with Part II is restricted to the potential boundary conditions (2), (3), (5), (6), and (10).

2.4. Result and Discussion

2.4.1. Distribution of Potential at Time Zero

The potential curves along the depth of the crevice are shown in Figure 4 As a reference, the location of the crevice opening was at position 0 on the x-axis and positive values are associated with increasing crevice depth towards the tip. The location of the peak current density Ecrit = 108 mV and a potential at which the surface is nearly passivated, Epass = 200 mV, were marked on this plot. In this paper, the position of Ecrit marks the minimum gap length required to initiate crevice corrosion. This position is referred to here as xcrit. As expected from the I∙R-drop corrosion model, the width increased and the position of Ecrit moved deeper inside the crevice. With the width increasing, the position of xcrit tended to deform in a roughly quadratic fashion (depression downward), denoting that the CPC moved into the deeper location of the crevice. Additionally reflected in Figure 4 is the relationship between xcrit and the crevice width W under different applied potentials. Compared with Figure 4a,b, applying a larger system potential led to a larger xcrit value, indicating that the higher applied potential caused the CPC to move deeper into the crevice. This is consistent with the relationship proposed by Abdulsalam [27] and Lee [33].
For time t = 0, the effects of different potentials on the current density and interfacial potential curves of Ni with a fixed gap W = 0.3 mm are shown in Figure 5. The parameters are shown in Table 1. In Figure 5a, the initiation position, as denoted by the location of icrit, was calculated to appear at approximately 2.5 mm along the crevice depth, that is, xcrit = 2.5 mm. For the passive-to-active polarization data from the passive region to the active region in Figure 5b, the location of xcrit was approximately 3.0 mm along the depth of the crevice, xcrit = 3.0 mm. In larger gaps, the deviation from the quadratic behavior was influenced both by the area under the anode curve and the depth of the crevice. This result is expected because the onset of the higher potential must be located at a larger L, which is consistent with the experimental results [33].

2.4.2. Distribution of Interface Potential

The potential profiles as a function of time for a 0.3 mm gap of crevice under different system potentials of 250 mV and 300 mV are shown in Figure 6. As shown on the plots, the locations of Ecrit and Epass from the polarization curve were marked. The potential changed quickly at the crevice opening, and the potential gradient at the opening was larger than that at the tip. Along the direction of crevice depth L, the change of potential tended to level off, which is consistent with experimental result [33]. With an increasing time, the location of Epass moved toward the gap opening while Ecrit moved away from the opening toward the gap tip. It can be explained from the following two aspects. First, as crevice damage began to develop at the location of Ecrit, the crevice tended to a larger width, with the result that the resistance between the opening and this location decreased. The movement of Ecrit to a deeper location can be reasonably explained by substituting the expression for R in Equation (1) into Ohm’s law. For a constant PD between the cathode and Ecrit and constant I(icrit), the x must change. Therefore, the PD related with Ecrit moved into the deeper crevice, and x increased. In addition, Epass moved toward the crevice opening and Ecrit transferred to the deeper point of crevice. The widths of these locations associated with current densities in the active peak increased. As a result, the total current near the opening of crevice increased.
As shown in Figure 7, the potential distribution for the applied potential of 250 mV and 50 h coincided with that of experimental results [25]. For the applied potential of 300 mV and 30 h, the experimental potential decreased faster than that of simulation, and compared with Lee [33] and Abdulsalam [35], it was found that all curves were consistent. However, it is also worth noting that the values of xcrit for a given gap did not agree under the applied potential; higher potentials resulted in higher values of xcrit, as would be expected from I∙R theory.

2.4.3. Distribution of Current Density during Corrosion

The curves of current density with time are shown in Figure 8. The current at every point is shown as the summation of the current representing the cells on the metal surface between the deepest location and that point. The width was fixed at the gap opening (or a little loss) and the current at that point increased with time, while the voltage increased with time. In other words, applying a constant voltage V, an increasing in I is associated with a decrease in x by Equation (1). The damage can be predicted when crevice corrosion proceeding in two directions are away from the gap opening when the location Ecrit appears at the deeper location inside the crevice and toward the opening. Along the crevice depth, the total current went down. In Figure 8a, when the crevice width was W = 0.3 mm and the potential is EA = 250 mV, the maximum current density appeared near x = 2.3 mm. In Figure 8b, the maximum is near x = 3.0 mm under EA = 300 mV. Over time, the peak current region became wider. Two effects can explain the change in the current density distribution: the decrease of Ohmic resistance inside the crevice due to the width W expanding and the increase of the contact surface area between the electrode and the electrolyte due to the electrode deformation.
That the current density here is basically matched with that of the result [27], and which is shown in Figure 9. The maximum value of corrosion current density in the experiment was consistent with that of simulation; the experimental current peak occurred at about L = 2.1 mm, and the simulated peak occurred at about L = 2.3 mm.

2.4.4. Damage Evolution of Ni Electrode

The damage evolution of the Ni metal surface into the crevice is shown in Figure 10. Because of the change in Ecrit and Epass, the damage area extended in directions from the onset point at x = 2.3 mm in Figure 10a and x = 3.0 mm in Figure 10b towards both the opening and the end of the gap. The damage deformation of the electrode surface near the crevice opening coincides with the change trend of current near the opening as mentioned above and the damage to the tip increased in line with Ecrit’s movement. This suggests that the shape of the current distribution in Figure 10 is not invariable. Conversely, the active-to-passive region grew, over time, to a larger area. This led to the observed sotted damage contour. Over time, the CDA expanded and moved toward the gap opening, consistent with an increase in current near the opening, and also toward the tip, in accordance with a decrease in potential.
The comparison of the damage evolution between simulation and experiment in Abdulsalam [35] is shown in Figure 11. When the potential was 250 mV, the experiment damage value was larger than that of simulation at the time of 50 h. The experiment damage threshold value was up to about 0.7 mm, and that of simulation was about 0.45 mm. At 300 mV system potential, the experiment damage was larger than that of simulation at the time of 150 h. The damage threshold value was up to about 1.1 mm, while the simulation damage threshold value was about 1.35 mm. From Figure 11, it can be seen that the fluctuation trend of experiment data and simulation data was consistent, and the corrosion point was located at about 2.3 mm on the damage section under the applied potential of 250 mV and 50 h. The experiment results were consistent with the simulation results. The CPC of experiment result appeared at about 2.7 mm along the depth at 300 mV and t = 150 h, and the CPC was about 3.0 mm on the simulated damage section.

2.4.5. Electrode Surface Damage

The damage curves as a function of crevice gap at time equal to 50 h were calculated, and the results are shown in Figure 12. Smaller gaps were related to a narrower CDA near the crevice opening, while at the largest crevice width, the CDA was far away from the opening in order to adapt to the decrease in I∙R voltage drop. However, at wider crevices, the potential displayed a variation by relatively small amounts as x’s location from the opening gradually increased. This caused a sporadic damage area where damage is more severe than that observed for smaller width crevices. Since the effect of mass transport on gap damage is not considered in this model, the increase of damage is likely to occur only in the structure with active-to-passive transition in the electrolyte.

3. Simulation of X100 Crevice Corrosion

Ni element can change the crystal structure of stainless steel. The addition of Ni can form an austenite structure, improving the corrosion resistance, plasticity, weldability, and toughness of stainless steel. In Section 2 of this paper, 2-D model of the damage evolution of crevice corrosion of Ni metal in acidic medium is studied, in which simulated results were matched with the public results [27,32,33,34,35,36]. This conclusion makes it possible to perform the simulation of crevice corrosion of stainless steel. In the following, the damage behaviors of X100 steel crevice corrosion in CO2 solution are simulated by COMSOL 5.6. Its chemical composition is shown in Table 2.

3.1. Geometric Model and Boundary Conditions

The 2-D model of crevice corrosion of X100 and the meshed model are shown in Figure 13a,b, respectively, in which the crevice depth L was 10 mm and the crevice width W was taken as 0.1–0.25 mm. In general, the crevice depth L is considered to be much larger than the crevice width W. The electrolyte solution was a saturated CO2 solution of 0.5 mol/L Na2SO4 with a conductivity of 0.1 S/m. The anodic polarization curve of X100 in a saturated CO2 solution of Na2SO4 at 20 °C is shown in Figure 14 [31]. The X100 steel surface in contact with the electrolyte solution was considered as the anode. In this model, only the electro-migration transfer was considered while the convection transfer and electrolyte solution diffusion were ignored; the current was generated by electromigration of ions only, and the electrolytes in part I and part II were well mixed. The geometric model and boundary conditions were the same as those of Ni in Figure 3.

3.2. Results and Analysis

3.2.1. Effect of Crevice Widths on Corrosion Damage

Crevice width is an important factor on corrosion damage; thus, here, different width of 0.1 mm, 0.15 mm, 0.2 mm, and 0.25 mm were used. Figure 15, Figure 16, Figure 17 and Figure 18 show the X100 steel electrode deformation with time at different crevice widths, where the numerical value of the legend on the right side represents the corrosion damage severity, unit μm.
Figure 19 shows that damage progressed along the gap depth, where, x = 1.9 mm, 2.1 mm, 2.5 mm, and 2.7 mm are from Figure 15, Figure 16, Figure 17 and Figure 18 and x = 3.0 mm is from Figure 10b. At the period of 0–50 weeks, the CDA of the X100 electrode surface gradually increased. As the crevice width increased, the CPC, xcrit moved deeper into the gap. Only the resistivity between the gap and electrolyte met the requirement of the voltage I∙R > Δφ*, and the crevice corrosion occurred in the metal/electrolyte system at the deep interval between the gap surface XA/P and the gap ended at x = 10 mm. Δφ* is defined in the metal/electrolyte system as the difference between the potential (EA = Ex = 0) at the opening of crevice (x = 0) of the passivation zone and the critical potential (Ex = EA/P) of the transition from activation zone to the passivation zone on the polarization curve. When the gap became larger, it can be seen from Equation (1) that only when the gap depth became larger could the I∙R > Δφ* condition be satisfied, resulting in corrosion.

3.2.2. Damage Evolution at Time 50 Weeks

The damage profiles inside the crevice with different width at time t = 50 weeks are shown in Figure 20. With the gap increased, the location of the CPC gradually moved into the deeper gap. The CDA began to expand and spread in both directions from initiation corrosion point xcrit toward the gap opening and the gap tip. In order to adapt to the corrosion conditions controlled by the I∙R drop, the CDA increased, as can be acquired from Equation (1). However, the corrosion damage threshold value basically remained unchanged, up to 0.83 mm. From damage Equation (10), applying a constant system potential, the corrosion damage maximum was related to the current density, but not to the crevice width.

4. Conclusions

A 2-D model of predicting the spatial-temporal damage evolution during crevice corrosion of Ni metal in sulfuric acid and X100 pipeline steel in CO2 well-mixed electrolyte solution was developed to simulate I∙R drop controlled corrosion and was consistent with some published results. Corrosion deformation, potential distribution, and current distribution on the metal surface were predicted during crevice corrosion.
(1) Under system with a constant potential, the damage of crevice corrosion of metal surface increased; when the gap increased, the critical point of corrosion inside the crevice moved into a deeper location, while the corrosion damage area gradually expanded, but the maximum corrosion damage value remained unchanged.
(2) For crevice corrosion controlled by I∙R voltage drop, the damage area inside the crevice expanded toward both the opening and the end of the gap. Since the potential drop in the passivation region increased with increasing current, the passivation potential point shifted towards the opening. As the crevice width increased and the electrolyte resistance decreased, the critical potential position at which the maximum crevice corrosion rate was reached moved deeper into the inner crevice.
(3) This 2-D model has the ability of predicting the spatial-temporal damage evolution that is not obtainable through the one-dimensional simplified model. The results provide a valuable explanation for variation of current density, and the crevice critical length-to-gap ratio necessary to meet the crevice corrosion controlled by I∙R drop theory. It is valuable to predict corrosion damage on the time and space scales.

Author Contributions

Conceptualization and methodology, W.S.; software, Z.L.; validation, W.S.; formal analysis, Z.L.; investigation, W.S. and Z.L.; resources, W.S.; data curation, Z.L.; writing—original draft preparation, W.S. and Z.L.; writing—review and editing, Z.L.; visualization, W.S. and Z.L.; supervision, W.S. and Z.L.; project administration, W.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data used to support the findings of this study are available from the corresponding author upon request.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Yao, R.; Zhao, J.; He, X.; Wang, L.; Liu, Y.D.; Gu, Y.H. Research Progress on Corrosion of High Strength Pipeline Steel in the Oilfield Produced Water. Mater. Prot. 2020, 53, 121–129. [Google Scholar] [CrossRef]
  2. Guo, J.Y.; Hu, J.; Li, Q.D.; Fu, Q.; Zhao, M.M. Research Progress on Corrosion and Protection of Oil and Gas Pipelines at Home and Abroad. Mater. Prot. 2017, 50, 83–87. [Google Scholar] [CrossRef]
  3. Varvara, S.H.; Anderi, N.; Flavien, V.; Nicolas, L.; Dominique, T. Effect of Cathodic Polarisation Switch-Off on the Passivity and Stability to Crevice Corrosion of AISI 304L Stainless Steel. Materials 2021, 14, 2921. [Google Scholar] [CrossRef]
  4. Torres, C.; Johnsen, R.; Iannuzzi, M. Crevice Corrosion of solution annealed 25Cr duplex stainless steels: Effect of W on critical temperatures. Corros. Sci. 2021, 178, 109053. [Google Scholar] [CrossRef]
  5. Adewale, G.; Joshua, O.I. Effect of Process Variables on The Crevice Corrosion in Type-304 Stainless Steels. Recent Innov. Chem. Eng. Former. Recent Pat. Chem. Eng. 2020, 13, 379–389. [Google Scholar]
  6. Yasin, O.; Kadir, M.D.; Abdullah, C.K. Hot corrosion behavior of YSZ, Gd2Zr2O7 and YSZ/Gd2Zr2O7 thermal barrier coatings exposed to molten sulfate and vanadate salt. Appl. Surf. Sci. 2018, 438, 96–113. [Google Scholar] [CrossRef]
  7. Yasin, O.; Abdullah, C.K.; Hayrettin, A. Comparison of calcium–magnesium-alumina-silicate (CMAS) resistance behavior of produced with electron beam physical vapor deposition (EB-PVD) method YSZ and Gd2Zr2O7/YSZ thermal barrier coatings systems. Vacuum 2021, 194, 110576. [Google Scholar] [CrossRef]
  8. Kadir, M.D.; Yasin, O.; Abdullah, C.K. TGO growth and kinetic study of single and double layered TBC systems. Surf. Coat. Technol. 2021, 415, 127135. [Google Scholar] [CrossRef]
  9. Yasin, O.; Kadir, M.D.; Hayrettin, A.; Abdullah, C.K. Investigation of calcium–magnesium–alumino–silicate (CMAS) resistance and hot corrosion behavior of YSZ and La2Zr2O7/YSZ thermal barrier coatings (TBCs) produced with CGDS method. Surf. Coat. Technol. 2021, 411, 126969. [Google Scholar] [CrossRef]
  10. Kadir, M.D.; Yasin, O.; Yasar, K.; Abdullah, C.K. Oxidation and hot corrosion resistance of HVOF/EB-PVD thermal barrier coating system. Surf. Coat. Technol. 2021, 409, 126862. [Google Scholar] [CrossRef]
  11. Ozgurluk, Y.; Doleker, K.M.; Karaoglanli, A.C. Investigation of the effect of V2O5 and Na2SO4 melted salts on thermal barrier coatings under cyclic conditions. Anti-Corros. Methods Mater. 2019, 66, 644–650. [Google Scholar] [CrossRef]
  12. Doleker, K.M.; Ozgurluk, Y.; Ahlatci, H.; Karaoglanli, A.C. Evaluation of oxidation and thermal cyclic behavior of YSZ, Gd2Zr2O7 and YSZ/Gd2Zr2O7 TBCs. Surf. Coat. Technol. 2019, 371, 262–275. [Google Scholar] [CrossRef]
  13. Kaplan, M.; Uyaner, M.; Yasin, O.; Doleker, K.M.; Karaoglanli, A.C. Evaluation of Hot Corrosion Behavior of APS and HVOF Sprayed Thermal Barrier Coatings (TBCs) Exposed to Molten Na2SO4 + V2O5 Salt at 1000 °C. Adv. Struct. Mater. 2019, 92, 441–459. [Google Scholar] [CrossRef]
  14. Cui, J.B. Analysis on Corrosion Management of Process Pipeline in Oil Transportation Station. Total Corros. Control 2020, 34, 58–59. [Google Scholar] [CrossRef]
  15. Richard, A.; Thor, T.; Kurt, H. The Critical Geometry for Initiation of Crevice Corrosion. J. Electrochem. Soc. 1985, 132, 1027–1031. [Google Scholar] [CrossRef]
  16. Kyehyun, C.; Mohammed, I.A.; Howard, W.P. The Effect of Electrolyte Properties on the Mechanism of Crevice Corrosion in Pure Iron. J. Electrochem. Soc. 1998, 145, 1862–1869. [Google Scholar] [CrossRef]
  17. Zhang, C.W.; Fu, T.L.; Chen, H.Y.; Gao, Y. Research Progress on Crevice Corrosion Plasma Nitriding and Surface Nanocrystallization of Titanium Alloys. Surf. Technol. 2019, 48, 114–123. [Google Scholar] [CrossRef]
  18. Lin, Q.H.; Zou, S.W.; Zhang, Z.H.; Qu, Y.C.; Wang, X.; Yuan, G.Q.; DAI, J.Y.; Fu, X.S. Crevice Corrosion Behavior of 2A12 Aluminum Alloy and Ti Alloy Lap Joint in Salt Spray Environment. Corros. Prot. 2021, 42, 1–6. [Google Scholar]
  19. Tadashi, S.; Yuichi, F.; Akira, T.; Yuji, H. Simulation of Solution Chemistry in Crevice Corrosion for Stainless Steel. ECS Trans. 2007, 11, 1938–5862. [Google Scholar] [CrossRef]
  20. Luo, X.F.; Zhang, W.L.; Zhai, W.G.; Zhang, H.K.; Liu, X.Y.; Zha, X.Q. Research on the Localized Corrosion Behavior of the 304L/Plain Carbon Steel Explosive Cladding Plate. Dev. Appl. Mater. 2020, 35, 91–97. [Google Scholar] [CrossRef]
  21. Joe, H.P.; Xi, S.; Arun, S.A.; Uziel, L. Crevice Corrosion Damage Evolution in High Temperature Brines. ECS Trans. 2007, 11, 1938–5862. [Google Scholar] [CrossRef]
  22. Ren, Y.; Cheng, G. Research Progress on Corrosion and Protection Simulation of Metal Materials in Marine Environment. Equip. Environ. Eng. 2019, 16, 93–98. [Google Scholar]
  23. Yeh, C.P.; Tsai, K.C.; Huang, J.Y. Influence of Chloride Concentration on Stress Corrosion Cracking and Crevice Corrosion of Austenitic Stainless Steel in Saline Environments. Materials 2020, 13, 5640. [Google Scholar] [CrossRef]
  24. Howard, W.P. Important Early Developments and Current Understanding of the IR Mechanism of Localized Corrosion. Electrochem. Soc. 2003, 150, K1–K13. [Google Scholar] [CrossRef]
  25. Howard, W.P. IR Voltage in Crevices during Crevice Corrosion and Sacrificial Cathodic Protection. Z. Für Phys. Chem. 2007, 221, 1441–1454. [Google Scholar] [CrossRef]
  26. Howard, W.P.; Frankenthal, R.P. On the Mechanism of Localized Corrosion of Iron and Stainless Steel: I. Electrochemical Studies. J. Electrochem. Soc. 1972, 119, 1297–1304. [Google Scholar] [CrossRef]
  27. Abdulsalam, M.I. The role of electrolyte concentration on crevice corrosion of pure nickel. Mater. Corros. 2015, 58, 511–513. [Google Scholar] [CrossRef]
  28. Kennell, G.F.; Evitts, R.W.; Heppner, K.L. A critical crevice solution and I R drop crevice corrosion model. Corros. Sci. 2008, 50, 1716–1725. [Google Scholar] [CrossRef]
  29. Xu, H.L.; Yin, S.M. Simulation of Crevice Corrosion in 45# Steel Pipeline. Surf. Technol. 2016, 45, 161–166. [Google Scholar]
  30. Song, F.M.; Sridhar, N. Modeling pipeline crevice corrosion under a disbonded coating with or without cathodic protection under transient and steady state conditions. Corros. Sci. 2008, 50, 70–83. [Google Scholar] [CrossRef]
  31. Kahyarian, A.; Brown, B.; Nesic, S. Electrochemistry of CO2 corrosion of mild steel: Effect of CO2 on iron dissolution reaction. Corros. Sci. 2017, 129, 146–151. [Google Scholar] [CrossRef]
  32. Stenta, A.; Basco, S.; Smith, A.; Clemons, C.B.; Golovaty, D.; Kreider, K.L.; Wilder, J.; Young, G.W.; Lillard, R.S. One-dimensional approach to modeling damage evolution in galvanic corrosion. Corros. Sci. 2014, 88, 36–48. [Google Scholar] [CrossRef] [Green Version]
  33. Lee, J.S.; Reedand, M.L.; Kelly, R.G. Combining Rigorously Controlled Crevice Geometry and Computational Modeling for Study of Crevice Corrosion Scaling Factors. Electrochem. Soc. 2004, 151, 423–433. [Google Scholar] [CrossRef]
  34. Brackman, M.D.; Clemons, C.B.; Golovaty, D.; Kreider, K.L.; Young, G.W.; Lillard, R.S.; Payer, J. Modeling and Computational Simulation of Crevice Corrosion Damage Evolution. J. Electrochem. Soc. 2014, 161, 237–245. [Google Scholar] [CrossRef]
  35. Abdulsalam, M.I.; Howard, W.P. The Effect of Crevice-Opening Dimension on the Stability of Crevice Corrosion for Nickel in Sulfuric Acid. J. Electrochem. Soc. 1998, 145, 2276. [Google Scholar] [CrossRef]
  36. Engelhardt, G.R.; Macdonald, D.D. Possible distribution of potential and corrosion current density inside corroding crevices. Electrochim. Acta 2012, 65, 266–274. [Google Scholar] [CrossRef]
Figure 1. 2-D electrochemical model for corrosion. The gray area is electrolyte. Not to scale.
Figure 1. 2-D electrochemical model for corrosion. The gray area is electrolyte. Not to scale.
Materials 15 02329 g001
Figure 2. Polarization curve for Ni electrode in sulfuric acid along the active-to-passive direction from Brackman [33], indicating the critical potential, Ecrit = 0.108 V, and passive potential, Epass = 0.20 V.
Figure 2. Polarization curve for Ni electrode in sulfuric acid along the active-to-passive direction from Brackman [33], indicating the critical potential, Ecrit = 0.108 V, and passive potential, Epass = 0.20 V.
Materials 15 02329 g002
Figure 3. The PBCs of inside and outside the crevice: (a) Part I; (b) Part II.
Figure 3. The PBCs of inside and outside the crevice: (a) Part I; (b) Part II.
Materials 15 02329 g003
Figure 4. Potential curves with varying crevice width W, at time t = 0 h: (a) the applied potential EA = 0.25 V; (b) the applied potential EA = 0.30 V.
Figure 4. Potential curves with varying crevice width W, at time t = 0 h: (a) the applied potential EA = 0.25 V; (b) the applied potential EA = 0.30 V.
Materials 15 02329 g004
Figure 5. Potential ESCE and current density for time t = 0 and W = 0.3 mm: (a) the applied potential EA = 0.25 V; (b) the applied potential EA = 0.30 V.
Figure 5. Potential ESCE and current density for time t = 0 and W = 0.3 mm: (a) the applied potential EA = 0.25 V; (b) the applied potential EA = 0.30 V.
Materials 15 02329 g005
Figure 6. Curves of potential versus depth for the width W = 0.3 mm at various times: (a) the applied potential EA = 0.25 V; (b) the applied potential EA = 0.30 V.
Figure 6. Curves of potential versus depth for the width W = 0.3 mm at various times: (a) the applied potential EA = 0.25 V; (b) the applied potential EA = 0.30 V.
Materials 15 02329 g006
Figure 7. Comparison of potential with experimental results from Abdulsalam [35].
Figure 7. Comparison of potential with experimental results from Abdulsalam [35].
Materials 15 02329 g007
Figure 8. Current density with time for W = 0.3 mm: (a) the applied potential EA = 0.25 V; (b) the applied potential EA = 0.30 V.
Figure 8. Current density with time for W = 0.3 mm: (a) the applied potential EA = 0.25 V; (b) the applied potential EA = 0.30 V.
Materials 15 02329 g008
Figure 9. Distribution of current density at time 50 h.
Figure 9. Distribution of current density at time 50 h.
Materials 15 02329 g009
Figure 10. The crevice damage evolution inside the gap over time. (a) the applied potential EA = 0.25 V; (b) the applied potential EA = 0.30 V.
Figure 10. The crevice damage evolution inside the gap over time. (a) the applied potential EA = 0.25 V; (b) the applied potential EA = 0.30 V.
Materials 15 02329 g010
Figure 11. Comparison damage evolution with the result from Abdulsalam [35]. The applied potential at time 50 h is 0.25 V, and the potential of the 150 h is 0.30 V.
Figure 11. Comparison damage evolution with the result from Abdulsalam [35]. The applied potential at time 50 h is 0.25 V, and the potential of the 150 h is 0.30 V.
Materials 15 02329 g011
Figure 12. Electrode damage as a function of crevice width after 50 h: (a) the applied potential EA = 0.25 V; (b) the applied potential EA = 0.30 V.
Figure 12. Electrode damage as a function of crevice width after 50 h: (a) the applied potential EA = 0.25 V; (b) the applied potential EA = 0.30 V.
Materials 15 02329 g012
Figure 13. 2D electrochemical model for X100 crevice corrosion: (a) the geometric model; (b) the meshed model.
Figure 13. 2D electrochemical model for X100 crevice corrosion: (a) the geometric model; (b) the meshed model.
Materials 15 02329 g013
Figure 14. Anodic polarization curve of X100 in 0.5 mol/L Na2SO4 saturated CO2 solution at 20 °C.
Figure 14. Anodic polarization curve of X100 in 0.5 mol/L Na2SO4 saturated CO2 solution at 20 °C.
Materials 15 02329 g014
Figure 15. Damage evolution of X100 crevice corrosion at width W = 0.1 mm: (a) 0 weeks; (b) 10 weeks; (c) 20 weeks; (d) 30 weeks; (e) 40 weeks; (f) 50 weeks.
Figure 15. Damage evolution of X100 crevice corrosion at width W = 0.1 mm: (a) 0 weeks; (b) 10 weeks; (c) 20 weeks; (d) 30 weeks; (e) 40 weeks; (f) 50 weeks.
Materials 15 02329 g015
Figure 16. Damage evolution of X100 steel crevice corrosion at width W = 0.15 mm: (a) 0 weeks; (b) 10 weeks; (c) 20 weeks; (d) 30 weeks; (e) 40 weeks; (f) 50 weeks.
Figure 16. Damage evolution of X100 steel crevice corrosion at width W = 0.15 mm: (a) 0 weeks; (b) 10 weeks; (c) 20 weeks; (d) 30 weeks; (e) 40 weeks; (f) 50 weeks.
Materials 15 02329 g016
Figure 17. Damage evolution of X100 crevice corrosion at width W = 0.20 mm: (a) 0 weeks; (b) 10 weeks; (c) 20 weeks; (d) 30 weeks; (e) 40 weeks; (f) 50 weeks.
Figure 17. Damage evolution of X100 crevice corrosion at width W = 0.20 mm: (a) 0 weeks; (b) 10 weeks; (c) 20 weeks; (d) 30 weeks; (e) 40 weeks; (f) 50 weeks.
Materials 15 02329 g017
Figure 18. Damage evolution of X100 crevice corrosion at width W = 0.25 mm: (a) 0 weeks; (b) 10 weeks; (c) 20 weeks; (d) 30 weeks; (e) 40 weeks; (f) 50 weeks.
Figure 18. Damage evolution of X100 crevice corrosion at width W = 0.25 mm: (a) 0 weeks; (b) 10 weeks; (c) 20 weeks; (d) 30 weeks; (e) 40 weeks; (f) 50 weeks.
Materials 15 02329 g018
Figure 19. The distribution of damage curves inside the crevice over time (d denotes damage profile and L denotes crevice depth): (a) W = 0.1 mm; (b) W = 0.15 mm; (c) W = 0.2 mm; (d) W = 0.25 mm.
Figure 19. The distribution of damage curves inside the crevice over time (d denotes damage profile and L denotes crevice depth): (a) W = 0.1 mm; (b) W = 0.15 mm; (c) W = 0.2 mm; (d) W = 0.25 mm.
Materials 15 02329 g019
Figure 20. Damage profiles inside the crevice as a function of width W at time t = 50 weeks.
Figure 20. Damage profiles inside the crevice as a function of width W at time t = 50 weeks.
Materials 15 02329 g020
Table 1. Basic parameter values.
Table 1. Basic parameter values.
VariableValueUnit
W0.3mm
EA0.25/0.30V
L10mm
M2mm
N2mm
Table 2. Chemical composition of X100 pipeline steel (mass, %).
Table 2. Chemical composition of X100 pipeline steel (mass, %).
CSiMnCrVTiNbCuNiMoAlSP
0.040.301.900.280.0070.0120.0710.520.570.340.0170.0040.011
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Su, W.; Liu, Z. Numerical Simulation of Damage Evolution and Electrode Deformation of X100 Pipeline Steel during Crevice Corrosion. Materials 2022, 15, 2329. https://doi.org/10.3390/ma15062329

AMA Style

Su W, Liu Z. Numerical Simulation of Damage Evolution and Electrode Deformation of X100 Pipeline Steel during Crevice Corrosion. Materials. 2022; 15(6):2329. https://doi.org/10.3390/ma15062329

Chicago/Turabian Style

Su, Wenxian, and Zhikuo Liu. 2022. "Numerical Simulation of Damage Evolution and Electrode Deformation of X100 Pipeline Steel during Crevice Corrosion" Materials 15, no. 6: 2329. https://doi.org/10.3390/ma15062329

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop