Next Article in Journal
Effect of Empagliflozin and Dapagliflozin on Ambulatory Arterial Stiffness in Patients with Type 2 Diabetes Mellitus and Cardiovascular Co-Morbidities: A Prospective, Observational Study
Previous Article in Journal
Pancreatic Tuberculosis—A Condition That Mimics Pancreatic Cancer
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Case Report

Near-Infrared Spectroscopy Intravascular-Ultrasound-Guided Intervention in Minimal Coronary Artery Stenosis: A Case Report

1
Division of Cardiology, Sahmyook Seoul Hospital, Seoul 02500, Korea
2
Division of Cardiology, Kyung Hee University Hospital, Seoul 02447, Korea
*
Author to whom correspondence should be addressed.
Medicina 2022, 58(9), 1166; https://doi.org/10.3390/medicina58091166
Submission received: 13 July 2022 / Revised: 21 August 2022 / Accepted: 26 August 2022 / Published: 27 August 2022
(This article belongs to the Section Cardiology)

Abstract

:
Near-infrared spectroscopy intravascular ultrasounds (NIRS-IVUSs) can identify high-risk plaque morphologies associated with future event risk. However, the usage of NIRS-IVUSs is not universal. We report a case with insignificant coronary angiography (CAG) and high-risk NIRS-IVUS findings. A 58-year-old man with exertional dyspnea was admitted for a CAG evaluation. The CAG of the patient demonstrated mild angiographic stenosis in the mid-left anterior descending artery. However, NIRS-IVUS revealed a high maximum lipid core burden index at 4 mm (MaxLCBI4mm) and an intraluminal calcific protrusion with severe luminal stenosis at the lesion. Therefore, the patient was diagnosed as stable angina, and a drug-eluting stent was implanted in the lesion. A post-stent NIRS-IVUS demonstrated improved MaxLCBI4mm and significantly improved luminal stenosis. The patient did not have any procedural complications. In the present case, a patient with insignificant CAG demonstrated multiple high-risk features on NIRS-IVUS. Therefore, a percutaneous coronary intervention was performed. The presented case highlights the utility of NIRS-IVUS in nonobstructive CAG.

1. Introduction

Although coronary artery angiography (CAG) has been a mainstay in the detection of the gross presence of coronary artery disease, it may underestimate the atherosclerotic burden and risks in lesions with nonobstructive luminograms. Where CAG provides two-dimensional information regarding the coronary artery, intravascular ultrasonography provides a continuum of tomographic images and, thus, yields more detailed information on vessel structure and plaque morphology [1]. Near-infrared spectroscopy intravascular ultrasounds (NIRS-IVUSs) combine spectroscopy with intravascular ultrasonography to further identify high lipid burdens and prove their clinical utility in cases with nonobstructive coronary artery angiography [2]. Here, we present the case of a patient with nonobstructive CAG in which NIRS-IVUS revealed multiple high-risk features in the lesion.

2. Case Report

A 58-year-old man with hypertension and end-stage renal disease (ESRD) who was on peritoneal dialysis visited an outpatient office with exertional dyspnea. He was never a smoker. His height was 163.6 cm, and his body weight was 80.1 kg. (body mass index: 30 kg/m2) The blood pressure of the patient was 140/90 mmHg, and the heart rate was 90 beats/min. Although the patient could be stratified as a moderate risk group based on SCORE2 scoring, ESRD was additionally considered for risk stratification [3]. Therefore, the patient was classified as high-risk and directly planned for CAG [4]. The patient showed mild stenosis in the mid-left anterior descending (LAD) artery in the exam (Figure 1).
In motion cinematography, a faint filling defect was noted in the lesion (Supplemental Video S1). The lesion was located relatively in the proximal part of LAD artery, and the contrast density within the lesion was inconsistent. The operator decided to evaluate high-risk plaque characteristics with NIRS-IVUS, for they may imply future event risk. Additional physiologic study was not performed for economic reasons. A NIRS-IVUS system was introduced beyond the lesion. Ultrasonography revealed a calcific protrusion (Figure 2a), and spectroscopy demonstrated a high lipid burden (Figure 2b and Supplemental Video S2). The maximum lipid core burden index at 4 mm (MaxLCBI4mm) was 462 (Figure 2c). The minimum lumen area (MLA) was 3.7 mm2, and the percent of area stenosis was 61.2%. This could be approximately translated into a percent diameter stenosis of 48%, which slightly did not meet significant stenosis. Despite absolute guideline cutoff in diameter, the stenosis was not enough for percutaneous coronary intervention (PCI), and the high lipid burden indicated by the MaxLCBI4mm and LAD location factors could impact future cardiac event risk [2,5]. To maximally benefit the future prognosis of the patient, the operator decided to perform a PCI.
An EBU 3.5 catheter was engaged, and a Runthrough NS Hypercoat guidewire was introduced and passed down to the distal part of the LAD artery. Balloon dilation was performed with a Tytrak 2.5 mm × 20 mm semi-compliant balloon. Sequentially, a Resolute Onyx 3.5 mm × 18 mm stent was implanted. Postdilation was performed with an Accuforce 3.5 mm × 15 mm non-compliant balloon, which was inflated to 22 ATM/3.75 mm. Postprocedural NIRS-IVUS pullback demonstrated no edge dissection, no malapposition, and minimal underexpansion (Figure 3a and Supplemental Video S3). The final CAG demonstrated excellent results (Figure 3b and Supplemental Video S4).
The post-stent MaxLCBI4mm, MLA, and percent of area stenosis were improved to 282, 8.9 mm2, and 13.2%, respectively. The postprocedural changes in the quantitative profiles of the lesions are described in Table 1. The patient did not have any periprocedural complication in 24 h of monitoring in the cardiovascular care unit. However, the symptoms were not completely relieved after the procedure. At the time, the NT-proBNP was 1797 pg/mL, and an echocardiogram of the patient demonstrated no left ventricular (LV) systolic pressure, no significant valvular dysfunction, no pulmonary hypertension, and grade 1 diastolic dysfunction (LV ejection fraction 65%; only trivial tricuspid regurgitation without elevated right ventricular systolic pressure). The potential causes for the symptom could be ESRD or obesity. The patient was planned to be followed-up with by the operator and the nephrologist. He was also educated with lifestyle modification, including dietary, behavioral, and weight loss management. Already prescribed aspirin at 100 mg, olmesartan at 40 mg, and furosemide at 80 mg per day at the nephrology department, the operator additionally prescribed clopidogrel at 75 mg, a combination pill of rosuvastatin at 10 mg and ezetimibe at 10 mg, bisoprolol at 2.5 mg, and nicorandil at 10 mg per day. After the discharge, the patient was free from any major cardiac event for 6 months.

3. Discussion

Although the patient was admitted for exertional dyspnea, a stent implantation was performed to prevent future cardiac events, such as cardiac death or myocardial infarction. MLA ≥ 4 mm2 was used as a cut-off for the lower event rate [6]. A MaxLCBI4mm over 400 and a 100-unit increase in NIRS-IVUS were shown to increase the risk for future events [2]. Luminal calcific protrusions are one of the major causes of acute coronary syndromes [7]. The operator identified a small MLA, a high MaxLCBI4mm, and calcific protrusions via NIRS-IVUS. The simultaneous presence of these high-risk factors could imply potential future cardiac events and, thus, a percutaneous coronary intervention (PCI) was performed. It should be noted that, while a greater MLA generally excludes functional ischemia, a smaller MLA does not necessarily result in it [8]. It is possible that the LAD lesion may not have been fully responsible for the exertional dyspnea of the patient; thus, the patient was followed-up with by the nephrologist.
Most studies regarding PCI in angina have shown no significant benefit in event-free survival [9], but intracoronary-imaging-based high-risk features in the LAD artery have been associated with an increased risk for future events [5]. The efficacy of preventing future events by LAD PCI is still under debate [10], and future studies involving intracoronary imaging and cardiac events are mandatory.

4. Conclusions

Although present consensus suggests the benefits of PCIs in stable coronary diseases are limited to symptom relieving, some prospective studies have suggested otherwise. The present case demonstrated that some high-risk lesion characteristics could be overlooked with CAG alone. Intravascular imaging techniques, such as NIRS-IVUS, may be considered in specific situations for PCIs in lesions with high-impact characteristics to minimize future event risk.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/medicina58091166/s1, Supplemental Video S1: CAG showing nonobstructive coronary artery; Supplemental Video S2: Initial NIRS-IVUS demonstrating multiple high-risk features; Supplemental Video S3: Post-PCI NIRS-IVUS; Supplemental Video S4: Post-PCI CAG.

Author Contributions

Conceptualization, H.-O.K. and W.K.; methodology, H.-O.K.; provision of patient data, J.K.; data curation, H.-O.K.; writing—original draft preparation, H.-O.K.; writing—review and editing, J.-S.W., J.K. and W.K.; visualization, H.-O.K.; supervision, J.-S.W. and W.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Written informed consent was obtained from the patient to publish this paper.

Data Availability Statement

All data shown in this study are included in the published article.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Darmoch, F.; Alraies, M.C.; Al-Khadra, Y.; Moussa Pacha, H.; Pinto, D.S.; Osborn, E.A. Intravascular Ultrasound Imaging–Guided Versus Coronary Angiography–Guided Percutaneous Coronary Intervention: A Systematic Review and Meta-Analysis. J. Am. Heart Assoc. 2020, 9, e013678. [Google Scholar] [CrossRef] [PubMed]
  2. Waksman, R.; Di Mario, C.; Torguson, R.; Ali, Z.A.; Singh, V.; Skinner, W.H.; Artis, A.K.; Cate, T.; Powers, E.; Kim, C.; et al. Identification of patients and plaques vulnerable to future coronary events with near-infrared spectroscopy intravascular ultrasound imaging: A prospective, cohort study. Lancet 2019, 394, 1629–1637. [Google Scholar] [CrossRef]
  3. Hageman, S.; Pennells, L.; Ojeda, F.; Kaptoge, S.; Kuulasmaa, K.; Vries, T.D.; Xu, Z.; Kee, F.; Chung, R.; Wood, A.; et al. SCORE2 risk prediction algorithms: New models to estimate 10-year risk of cardiovascular disease in Europe. Eur. Heart J. 2021, 42, 2439–2454. [Google Scholar] [CrossRef]
  4. Saraste, A.; Knuuti, J. ESC 2019 guidelines for the diagnosis and management of chronic coronary syndromes. Herz 2020, 45, 409–420. [Google Scholar] [CrossRef] [PubMed]
  5. Prati, F.; Romagnoli, E.; Gatto, L.; La Manna, A.; Burzotta, F.; Ozaki, Y.; Marco, V.; Boi, A.; Fineschi, M.; Fabbiocchi, F.; et al. Relationship between coronary plaque morphology of the left anterior descending artery and 12 months clinical outcome: The CLIMA study. Eur. Heart J. 2019, 41, 383–391. [Google Scholar] [CrossRef] [PubMed]
  6. Abizaid, A.; Mintz, G.S.; Pichard, A.D.; Kent, K.M.; Satler, L.F.; Walsh, C.L.; Popma, J.J.; Leon, M.B. Clinical, intravascular ultrasound, and quantitative angiographic determinants of the coronary flow reserve before and after percutaneous transluminal coronary angioplasty. Am. J. Cardiol. 1998, 82, 423–428. [Google Scholar] [CrossRef]
  7. Virmani, R.; Kolodgie, F.D.; Burke, A.P.; Farb, A.; Schwartz, S.M. Lessons From Sudden Coronary Death. Arterioscler. Thromb. Vasc. Biol. 2000, 20, 1262–1275. [Google Scholar] [CrossRef] [PubMed]
  8. Kang, S.-J.; Lee, J.-Y.; Ahn, J.-M.; Mintz, G.S.; Kim, W.-J.; Park, D.-W.; Yun, S.-C.; Lee, S.-W.; Kim, Y.-H.; Lee, C.W.L.; et al. Validation of Intravascular Ultrasound–Derived Parameters With Fractional Flow Reserve for Assessment of Coronary Stenosis Severity. Circ. Cardiovasc. Interv. 2011, 4, 65–71. [Google Scholar] [CrossRef] [PubMed]
  9. Maron, D.J.; Hochman, J.S.; Reynolds, H.R.; Bangalore, S.; O’Brien, S.M.; Boden, W.E.; Chaitman, B.R.; Senior, R.; López-Sendón, J.; Alexander, K.P.; et al. Initial Invasive or Conservative Strategy for Stable Coronary Disease. N. Engl. J. Med. 2020, 382, 1395–1407. [Google Scholar] [CrossRef]
  10. Roguin, A.; Solomonica, A.; von Birgelen, C. Is the proximal left anterior descending coronary artery segment justifiably considered as the last frontier for stenting? EuroIntervention 2018, 14, 729–731. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Mild stenosis (arrow) was noted in the mid-LAD artery in the RAO cranial view. RAO, right anterior oblique; CAG, coronary angiography; LAD, left anterior descending.
Figure 1. Mild stenosis (arrow) was noted in the mid-LAD artery in the RAO cranial view. RAO, right anterior oblique; CAG, coronary angiography; LAD, left anterior descending.
Medicina 58 01166 g001
Figure 2. NIRS-IVUS images of the nonobstructive coronary artery lesion. NIRS-IVUS pullback revealing a calcific protrusion in the lesion area (a) and high lipid burden (b). The LCBI spread-out plot reports a MaxLCBI4mm of 462 (c). LCBI, lipid core burden index; MaxLCBI4mm, maximum lipid core burden index at 4 mm; NIRS-IVUS, near-infrared spectroscopy intravascular ultrasound.
Figure 2. NIRS-IVUS images of the nonobstructive coronary artery lesion. NIRS-IVUS pullback revealing a calcific protrusion in the lesion area (a) and high lipid burden (b). The LCBI spread-out plot reports a MaxLCBI4mm of 462 (c). LCBI, lipid core burden index; MaxLCBI4mm, maximum lipid core burden index at 4 mm; NIRS-IVUS, near-infrared spectroscopy intravascular ultrasound.
Medicina 58 01166 g002
Figure 3. Post-procedural NIRS-IVUS and CAG images. NIRS-IVUS pullback after the non-compliant balloon demonstrated no edge dissection, no malapposition, and minimal underexpansion (a). Final CAG showed excellent results (b). CAG, coronary angiography; NIRS-IVUS, near-infrared spectroscopy intravascular ultrasound.
Figure 3. Post-procedural NIRS-IVUS and CAG images. NIRS-IVUS pullback after the non-compliant balloon demonstrated no edge dissection, no malapposition, and minimal underexpansion (a). Final CAG showed excellent results (b). CAG, coronary angiography; NIRS-IVUS, near-infrared spectroscopy intravascular ultrasound.
Medicina 58 01166 g003
Table 1. Quantitative NIRS-IVUS profiles before and after PCI.
Table 1. Quantitative NIRS-IVUS profiles before and after PCI.
ProfilesPre-PCIPost-PCI
LCBI211114
maxLCBI4mm462282
Minimum dRD (mm)2.93.1
Maximum dRD (mm)3.63.8
dRA (mm2)8.810.0
Minimum pRD (mm)3.33.5
Maximum pRD (mm)4.03.9
pRA (mm2)10.310.5
Minimum MLD/MSD (mm)1.82.9
Maximum MLD/MSD (mm)2.53.7
MLA and MSA (mm2)3.78.9
Area stenosis (%)61.213.2
Lesion and stent length (mm)1718
dRA, distal reference area; dRD, distal reference diameter; LCBI, lipid core burden index; MaxLCBI4mm, maximum lipid core burden index at 4 mm; MLA, minimum lumen area; MLD, minimum lumen diameter; MSA, minimum stent area; MSD, minimum stent diameter; NIRS-IVUS, near-infrared spectroscopy intravascular ultrasonography; PCI, percutaneous coronary intervention; pRA, proximal reference area; pRD, proximal reference diameter.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Kim, H.-O.; Woo, J.-S.; Kim, J.; Kim, W. Near-Infrared Spectroscopy Intravascular-Ultrasound-Guided Intervention in Minimal Coronary Artery Stenosis: A Case Report. Medicina 2022, 58, 1166. https://doi.org/10.3390/medicina58091166

AMA Style

Kim H-O, Woo J-S, Kim J, Kim W. Near-Infrared Spectroscopy Intravascular-Ultrasound-Guided Intervention in Minimal Coronary Artery Stenosis: A Case Report. Medicina. 2022; 58(9):1166. https://doi.org/10.3390/medicina58091166

Chicago/Turabian Style

Kim, Hyung-Oh, Jong-Shin Woo, Joan Kim, and Weon Kim. 2022. "Near-Infrared Spectroscopy Intravascular-Ultrasound-Guided Intervention in Minimal Coronary Artery Stenosis: A Case Report" Medicina 58, no. 9: 1166. https://doi.org/10.3390/medicina58091166

Article Metrics

Back to TopTop