Next Article in Journal
A Gold Nanoclusters Film Supported on Polydopamine for Fluorescent Sensing of Free Bilirubin
Previous Article in Journal
Electrophoretic Separation on an Origami Paper-Based Analytical Device Using a Portable Power Bank
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Correction

Correction: Tang, K., et al., A Novel Fingerprint Sensing Technology Based on Electrostatic Imaging. Sensors 2018, 18, 3050

State Key Laboratory of Mechatronics Engineering and Control, Beijing Institute of Technology, Beijing 100081, China
*
Author to whom correspondence should be addressed.
Sensors 2019, 19(7), 1725; https://doi.org/10.3390/s19071725
Submission received: 4 April 2019 / Accepted: 9 April 2019 / Published: 10 April 2019
The authors wish to make the following corrections to this paper [1]:
We have found one inadvertent error in our paper published in this journal [1]:
At the beginning of Section 4, “Sensor Measurement Results”, we missed a paragraph as follows:
The prototype of the Micro-electromechanical Systems (MEMS) and Integrated Circuit (IC) composite structure requires a long lifecycle and a high cost. The Charge Coupled Device (CCD) chip has a charge coupling and amplification function, so the electrostatic imaging principle was verified by using the modified CCD chip. By removing the filter on the CCD surface, a prototype of a fingerprint sensor based on electrostatic imaging was built. In a dull environment, the modified CCD chip generates an induced charge on the electrostatic field through the surface pixel and uses the charge amplifying circuit to perform induced charge amplification to realize the electrostatic imaging function. Compared with the sensor designed in the third section of the thesis, the modified CCD chip has fewer shield electrodes and can only achieve single-shot electrostatic imaging; however, it can verify the electrostatic imaging principle and design scheme proposed in the paper.
This change has no material impact on the conclusions of our paper. We apologize to our readers.

Reference

  1. Tang, K.; Liu, A.; Wang, W.; Li, P.; Chen, X. A Novel Fingerprint Sensing Technology Based on Electrostatic Imaging. Sensors 2018, 18, 3050. [Google Scholar] [CrossRef] [PubMed]

Share and Cite

MDPI and ACS Style

Tang, K.; Liu, A.; Wang, W.; Li, P.; Chen, X. Correction: Tang, K., et al., A Novel Fingerprint Sensing Technology Based on Electrostatic Imaging. Sensors 2018, 18, 3050. Sensors 2019, 19, 1725. https://doi.org/10.3390/s19071725

AMA Style

Tang K, Liu A, Wang W, Li P, Chen X. Correction: Tang, K., et al., A Novel Fingerprint Sensing Technology Based on Electrostatic Imaging. Sensors 2018, 18, 3050. Sensors. 2019; 19(7):1725. https://doi.org/10.3390/s19071725

Chicago/Turabian Style

Tang, Kai, Aijia Liu, Wei Wang, Pengfei Li, and Xi Chen. 2019. "Correction: Tang, K., et al., A Novel Fingerprint Sensing Technology Based on Electrostatic Imaging. Sensors 2018, 18, 3050" Sensors 19, no. 7: 1725. https://doi.org/10.3390/s19071725

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop