Abstract

Active Conversion of Bubbly Flow into Slug and Annular Flow during Microchannel Flow Boiling Using Thin-Film Platinum Microheaters †

Department of Microsystems Engineering, University of Freiburg, 79110 Freiburg, Germany
*
Author to whom correspondence should be addressed.
Presented at the XXXV EUROSENSORS Conference, Lecce, Italy, 10–13 September 2023.
Proceedings 2024, 97(1), 13; https://doi.org/10.3390/proceedings2024097013
Published: 14 March 2024

Abstract

:
This paper reports, for the first time, on the use of thin-film platinum microheaters to influence the flow boiling of DI water in microchannels with rapid low power heating pulses. A custom-designed control module allows microheaters to be actuated simultaneously and independently, enabling precise local control of flow regimes along an entire channel. In this study, bubbly flow was converted into a slug and annular flow. This pioneering technique promises a radical improvement in the heat transfer and performance of flow-boiling cooling devices by actively targeting flow conditions with high heat dissipation.

1. Introduction

Two-phase flow boiling in microchannels, i.e., the partial conversion of a fluid into steam, has been one of the most important research topics in the field of heat transfer for the last decades, especially because of its promising application in high heat flux cooling of electronic chips and components [1]. At high steam quality, the slug and annular flow regimes of two-phase flow exhibit the highest heat transfer coefficients. Therefore, it is of great interest to keep the flow-boiling process in these two regimes in order to maximize heat transfer. We do this by influencing the flow regime via local heating, using thin-film platinum heaters located at one microchannel side wall [2]. In comparison to this active flow regime manipulation, two-phase flow boiling is currently only controlled passively by global parameters such as mass flow rate, global heat input, channel dimensions, and restrictions of the channel geometry.

2. Materials and Methods

A Pyrex glass lid with an array of 17 platinum microheaters with a thickness of 200 nm, a width of 300 µm, and lengths from 0.5 mm to 2 mm (Figure 1a) was pressed onto a stainless-steel microchannel such that all heaters were in direct contact with the flowing DI water. All platinum structures had electroplated gold pads at each end that served as electrical contacts for spring probes. An O-ring in a trench surrounding the microchannel provided a hermetic seal between the microchannel and the glass cover. To induce flow boiling, 11 heater cartridges inserted into holes at the microchannel bottom were subjected to a specific heating power. A high-temperature stable 3D-printed reactor enclosure provided mechanical fixation and thermal isolation for all components. Figure 1b shows an exploded view of the experimental apparatus. A high-speed camera was mounted above to study boiling through the transparent glass lid. A micro annular gear pump passed the DI water through the microchannel at a mass flow rate of 1.5 g min−1.

3. Discussion

Figure 2a shows a bubbly flow at a fixed location of the microchannel. For this purpose, the 11 heater cartridges were heated with a total power of 14.18 W. Figure 2b illustrates the transition of this bubbly flow into a slug and annular flow with a 0.5 mm long microheater pulsed with a heating power of 870 mW. As seen in Figure 2, a heating pulse length of 110 ms was required to generate a slug flow, and a heating pulse of 205 ms was sufficient to generate an annular flow.

Author Contributions

Writing—review and editing, supervision, funding acquisition, project administration, P.W.; software, S.A.; conceptualization, methodology, validation, formal analysis, investigation, resources, data curation, writing—original draft preparation, visualization, M.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the German Research Foundation (DFG) under Grant No. WO 883/24-2.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Dataset available on request from the authors.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Cheng, L.; Xia, G. Fundamental issues, mechanisms and models of flow boiling heat transfer in microscale channels. Appl. Thermal Eng. 2017, 115, 1372–1397. [Google Scholar] [CrossRef]
  2. Schepperle, M.; Ghanam, M. Noninvasive platinum thin-film microheater/temperature sensor array for predicting and controlling flow boiling in microchannels. Sens. Actuator A Phys. 2022, 345, 113811. [Google Scholar] [CrossRef]
Figure 1. Pyrex glass lid with 17 platinum microheaters (a); CAD drawing of experimental apparatus consisting of the 3D-printed reactor housing, stainless-steel microchannel, glass lid with microheaters, cartridge heaters, and spring probes for electrical contact formation to the microheaters (b).
Figure 1. Pyrex glass lid with 17 platinum microheaters (a); CAD drawing of experimental apparatus consisting of the 3D-printed reactor housing, stainless-steel microchannel, glass lid with microheaters, cartridge heaters, and spring probes for electrical contact formation to the microheaters (b).
Proceedings 97 00013 g001
Figure 2. Time frames of a bubbly flow (a) and time frames of a bubbly flow affected by an 870 mW heating pulse from a 0.5 mm long microheater (b). All frames were acquired with DI water at a mass flow rate of 1.5 g min−1 using a high-speed camera at 2000 frames per second.
Figure 2. Time frames of a bubbly flow (a) and time frames of a bubbly flow affected by an 870 mW heating pulse from a 0.5 mm long microheater (b). All frames were acquired with DI water at a mass flow rate of 1.5 g min−1 using a high-speed camera at 2000 frames per second.
Proceedings 97 00013 g002
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Schepperle, M.; Arnold, S.; Woias, P. Active Conversion of Bubbly Flow into Slug and Annular Flow during Microchannel Flow Boiling Using Thin-Film Platinum Microheaters. Proceedings 2024, 97, 13. https://doi.org/10.3390/proceedings2024097013

AMA Style

Schepperle M, Arnold S, Woias P. Active Conversion of Bubbly Flow into Slug and Annular Flow during Microchannel Flow Boiling Using Thin-Film Platinum Microheaters. Proceedings. 2024; 97(1):13. https://doi.org/10.3390/proceedings2024097013

Chicago/Turabian Style

Schepperle, Mark, Sebastian Arnold, and Peter Woias. 2024. "Active Conversion of Bubbly Flow into Slug and Annular Flow during Microchannel Flow Boiling Using Thin-Film Platinum Microheaters" Proceedings 97, no. 1: 13. https://doi.org/10.3390/proceedings2024097013

Article Metrics

Back to TopTop