Next Article in Journal
Fabrication of an Organogel-Based Transdermal Delivery System of Loxoprofen Sodium
Previous Article in Journal
Analytical Investigation of Cyclodextrin Complexation Using the Co-Grinding Technique in the Case of Terbinafine Hydrochloride
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Proceeding Paper

The Application of 13C NMR and Untargeted Multivariate Analysis for Classifying Virgin Coconut Oil †

by
Lolita G. Lagurin
,
Mark Joseph M. Garrovillas
and
Fabian M. Dayrit
*
Department of Chemistry, School of Science and Engineering, Ateneo de Manila University, Quezon City 1108, Philippines
*
Author to whom correspondence should be addressed.
Presented at the 1st International Electronic Conference on Food Science and Functional Foods, 10–25 November 2020; Available online: https://foods_2020.sciforum.net/.
Proceedings 2021, 70(1), 54; https://doi.org/10.3390/foods_2020-07718
Published: 10 November 2020

Abstract

:
Virgin coconut oil (VCO) is produced from fresh mature coconut meat without the use of chemicals or high heat. VCO can be made using three processes: fermentation, centrifuge, and expeller. To determine quality, it is important to be able to differentiate control VCO (fresh) from old VCO, refined bleached and deodorized coconut oil (RBDCO), and VCO which has been adulterated with RBDCO. Differentiating these types of samples has remained a challenge because of their chemical similarity. This study investigated the ability of 13C NMR and multivariate analysis to differentiate these different coconut oil samples. The methodology used the standard 13C NMR pulse sequence with broadband 1H decoupling with dioxane as the internal standard (IS). After pre-processing of the spectra (alignment, bucketing/binning, normalization with respect to dioxane IS peak), untargeted multivariate analyses, both unsupervised and supervised, were done on the bins of the 13C peaks. Principal components analysis (PCA), a linear unsupervised method, was able to differentiate control VCO (n = 57) from RBDCO (n = 21), adulterated VCO (n = 9), and old VCO (n = 11). Partial least squares–discriminant analysis (PLS–DA) was used as the supervised linear binary classifier. Using overall accuracy and AUC-ROC curves (by 100 cross validation and single validation using manual holdout), the supervised dataset with an optimized model gave performances that were 99%, 95%, and 80% improved in differentiating control VCO vs. RBDCO, old VCO, and adulterated VCO (one vs. one), respectively. Predictive ability (Q2 < 0.20) and overall accuracy (<0.80) were poor compared to the previous models for binary classifier models (one vs. rest) to differentiate among the three VCO processes. This may be due to the variations in production conditions and methods that different VCO producers use. We conclude that 13C NMR combined with linear techniques can be used to accurately differentiate fresh VCO from RBDCO, old VCO, and adulterated VCO.

1. Introduction

Virgin coconut oil (VCO) is an oil that is recognized as a functional food which has been gaining popularity worldwide. VCO is defined as the oil that is obtained directly from fresh mature coconut meat without the use of chemicals and high heat [1] and can be produced using three main processes: fermentation, centrifuge, and expeller. In the fermentation and centrifuge processes, coconut milk is prepared from the fresh coconut meat. The fermentation process takes advantage of the presence of natural microorganisms that release lipase and other demulsifiers to destabilize the emulsion and separate the coconut oil layer. The crude coconut oil is filtered, dried, and is sometimes subjected to centrifugation. In the centrifuge process, the coconut milk is centrifuged to directly separate the oil from the aqueous layer. Many producers use a three-pass centrifuge system. The expeller process passes the coconut meat directly through an expeller press to squeeze out the oil [2]. In contrast, coconut oil that is used for frying is produced from copra and is refined, bleached, and deodorized and is referred to here as RBDCO.
Because VCO and RBDCO have similar physio-chemical characteristics, it is difficult to distinguish between them using classical techniques, and it is even more difficult to detect the adulteration of VCO with RBDCO. The reported methods of detecting adulteration using a different vegetable oil as an adulterant are inadequate for this purpose. Fourier transform infrared (FTIR) spectroscopy and differential scanning calorimetry (DSC) have been used to differentiate VCO from non-coconut oil samples, but these have not been applied to the adulteration of VCO with RBDCO [3,4].
NMR is a nondestructive, unbiased method of analyzing organic compounds. Comparing 1H and 13C NMR, the latter has a wider chemical shift range and gives singlets resulting in simpler spectra with less problems related to overlapping peaks in comparison to spectra across different magnetic field strengths. 13C NMR is also less susceptible to solvent and temperature effects. As 13C NMR is less sensitive than 1H NMR, it requires a longer acquisition time. Although broadband 1H-decoupled 13C NMR cannot be integrated, 13C NMR analysis is reproducible and can be used for the profiling of organic samples. Quantitative 13C NMR analysis can be done using an inverse-gated decoupling pulse sequence, but this requires long recycle delays. Although the use of relaxation agents may shorten the repetition time when using quantitative 13C NMR, the 13C NMR profile is suitable only for chemometric pattern recognition and untargeted multivariate analysis, but not for targeted quantification [5].
The statistical pipeline follows a typical multivariate method used in metabolomics [6,7]. 13C NMR profiles were pre-processed, aligned, bucketed, normalized, and auto-scaled. Linear methods were applied to the data. Exploratory unsupervised analysis, such as principal component analysis (PCA), was used to infer patterns and clustering within the dataset. Binary classifiers were developed for the better evaluation of model performance compared to multi-class classifiers in supervised analysis. Partial least squares–discriminant analysis (PLS–DA), a linear method, was then used for supervised analysis. The suitability of using a PLS–DA model (as it tends to overfit) was evaluated by the overall accuracy and the R2 (linear fit of training data) and Q2 (linear fit of predicted data/prediction performance on new data) parameters. The resulting models were then optimized for number of PLS–DA variables and a number of features by being internally cross-validated by random class assignments, manually single-validated using a manual holdout, and evaluated on ROC-based performance and predictive ability [8].
Receiver operating characteristics (ROC) are a diagnostic tool used to discriminate two samples based on a binary classifier system and a discrimination threshold for organizing classifiers and visualizing their performance. An ROC graph is a plot used to visualize the performance of the differentiation. The ROC curve plots the true positive rate (sensitivity) on the y axis against the false-positive rate (1-specificity) on the x axis. The area under the curve (AUC) of an ROC curve is used to quantify the performance of a binary classifier, a normal or control versus an abnormal or not controlled characteristic. Both the ROC curve and its corresponding AUC are functions of sensitivity and specificity of a prediction model. A perfect test will have an AUC value of 1.0, whereas a random chance will have a value of 0.5. In interpreting the AUC values we used the following: 1.0 is a perfect test, 0.9–0.99 is an excellent test, 0.8–0.89 is a good test, 0.7–0.79 is a fair test, 0.51–0.69 is a poor test, and 0.5 is of no value or is an unusable test [9].
The predictive performance of a model can be measured by permutation testing to determine whether it is statistically significant or not. A p-value < 0.05 means that given a randomly permuted outcome variable, there is less than 5% chance that a model of similar performance to the ‘‘true’’ non-permuted model will be produced.

2. Research Objectives

The goal of this research is to develop a 13C NMR method that can be used to differentiate VCO from RBDCO, from VCO adulterated with RBDCO, and old VCO (VCO which is beyond the shelf life of two years). Additionally, we also investigated whether this method will be able to differentiate VCO according to the type of production process, that is, fermentation, centrifuge, or expeller.

3. Materials and Methods

3.1. Oil Samples

Total VCO samples (n = 98) were divided into two groups: sample types—control VCO (n = 57) and not control VCO (n = 41). The control VCO (n = 57) comprised of two VCO oil types—the observed (n = 42), and the submitted (n = 15) samples. The observed and the submitted samples were acquired from the VCO producers of the Philippines who committed to participate in the study. Three to four manufacturers per process (fermentation, centrifuge, and expeller) were enrolled. Each manufacturer provided two oil type samples: observed and submitted. The observed samples were gathered by the researchers while observing the full VCO production process. The submitted samples were produced unobserved by the researchers. The observed samples constituted the training samples, while the submitted samples were the validation samples.
The sample type not control VCO (n = 41) consisted of the following oil types: old VCO (n = 11), adulterated VCO (n = 9), and RBDCO (n = 21). The old/degraded VCO samples included samples which were subjected to accelerated degradation at 40 °C for 6 months and samples which were over 2 years old. The adulterated VCO samples were composed of fermentation, centrifuge, and expeller samples that were adulterated with an RBDCO sample by 25%, 50%, and 75%.

3.2. Chemicals, Reagents, and Sample Preparation

Deuterated chloroform (CDCl3) with 0.05% v/v trimethyl silane (TMS) was used as the NMR solvent (cat# DLM-7TB-100S, Cambridge Isotope Laboratories, Inc.). 1,4-dioxane (cat# 1.09671, Merck ACS, ISO grade) was used as the internal standard (IS).
Approximately 350 µL of the oil sample was transferred into a 5 mm Wilmad High Throughput NMR tube (WG-1000-8-50) and about 230 µL of the CDCl3 solvent containing 2.9% w/w 1,4-dioxane was added. 1,4-dioxane was added as the IS for normalizing the metabolite bucket integrations. The mixture was shaken to homogenize the sample.

3.3. Instrumentation and Experimental Parameters

An Avance Neo 400 nuclear magnetic resonance (NMR) spectrometer (Bruker Biospin) was used operating at 100.097 MHz 13C. A standard Bruker 13C pulse sequence was used (C13CPD/zgpg30) with 64k (65,536) acquisition points, 4k (4096) scans, 1.38 s acquisition time, spectral width from −18.6 ppm to 219.3 ppm (23,809.523 Hz) with autogain settings and run at VT = 300 Kelvin.

3.4. Data Processing

Processed NMR spectra used standard automatic Bruker Topspin 4.0.7 13C post-processing third party packages, and statistical frameworks of the R Statistical software were used for the batch processing of spectra and in the unsupervised and supervised analyses. NMRProcFlow [10] was used for batch processing of peak shifting, spectral alignment, and variable bucketing. MetaboAnalyst 4.0 [11] was used for the data normalization and statistical analyses (untargeted, multivariate; unsupervised and supervised).

4. Results

4.1. Unsupervised Analysis

Preliminary exploratory unsupervised analyses were done in the context of the research objectives. Using 13C NMR untargeted profiling and linear methods: can we differentiate control VCO samples from RBDCO samples and other VCO samples not considered control? Can we differentiate by VCO process?
Binary classifiers were designed so that model performance can be easily evaluated by ROC curves. These binary classifiers were then used in supervised analyses and on the test samples: control vs. not control VCO (one vs. one); control VCO vs. RBDCO; control VCO vs. old VCO; and control VCO vs. adulterated VCO. Control VCO samples were used for the VCO process binary classifiers (one vs. rest): fermented VCO vs. not fermented VCO; centrifuged VCO vs. not centrifuged VCO; and expeller VCO vs. not expeller VCO.
2D unsupervised exploratory PCA plots for the binary classifiers for control VCO vs. not control VCO are shown in Figure 1, where control VCO vs. RBDCO is clearly separated. Some overlap is seen for control VCO vs. old VCO. There is significant overlap and no clear separation seen for the binary classifiers for the VCO processes.

4.2. Supervised Analysis

PLS–DA performance of control VCO vs. RBDCO indicates it is a perfect model and statistically significant (Figure 2). The optimal Q2 is determined to be four PLS–DA components with overall accuracy of about 1. Preliminary permutation tests indicate a p-value < 0.001 (0/1000 permutations). Monte Carlo cross validation (MCCV) indicates the model is a perfect classifier with most of the AUC for the ROC curves being 1. We get the same performance for a model built with buckets with AUC > 0.99 for 100 CV and for holdout data. There is good and clear separation between samples of the two classes. The predictive accuracy of the assembled model using a permutation test with 1000 permutations is statistically significant, p < 0.001.
The PLS–DA classifiers for the control VCO processes (fermentation vs. not fermentation, centrifuge vs. not centrifuge, and expeller vs. not expeller) indicated poor model performance, with some having comparatively high p-values.

5. Discussion

Based on the unsupervised analyses, we expect that differentiating control VCO from RBDCO, from VCO adulterated with RBDCO, and from old VCO samples is feasible, but differentiating by VCO process is not feasible. The control VCO vs. RBDCO classifier is essentially a perfect model and very highly statistically significant. The control VCO vs. old VCO classifier may also be considered an excellent model, and marginally close to the cutoff of p-value = 0.05. This may be improved with more old VCO samples.
The control VCO vs. adulterated VCO classifier is a mixed bag. Although the model performance may be considered good from a practical application, it was not statistically significant, meaning that there may be a significant number of models with random labeling assignments that will perform better than the optimized model. We hope to determine in future studies if the statistical significance of the model can be improved with more samples of adulterated VCO.

6. Summary and Conclusions

The use of 13C NMR and multivariate linear statistical methods were sufficient to discriminate the following: control VCO from RBDCO; control VCO from old VCO; and control VCO from VCO adulterated with RBDCO. The accuracy of discriminating VCO samples produced by different processes proved to be inadequate. Figure 3 summarizes the results and conclusions.

Supplementary Materials

The following are available online at https://www.mdpi.com/article/10.3390/foods_2020-07718/s1.

Author Contributions

Conceptualization: F.M.D.; methodology: L.G.L. and M.J.M.G.; software and formal analysis: M.J.M.G.; writing and editing: M.J.M.G., L.G.L. and F.M.D.; supervision and project administration: F.M.D. All authors have read and agreed to the published version of the manuscript.

Funding

This work was funded by the Philippine Council for Industry and Energy and Emerging Technologies Research and Development, Department of Science and Technology (PCIEERD-DOST).

Institutional Review Board Statement

Not Applicable.

Informed Consent Statement

Not Applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

We would like to thank the Virgin Coconut Oil Producers and Traders Association of the Philippines, Inc. for assistance with the acquisition of the samples; our research collaborator, University of the Philippines, College of Home Economics; and Grace B. Tantengco and Jerika Marie A. Arceo for assistance with sample preparation.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. PNS/BAFPS-22:2007. Philippine National Standard for Virgin Coconut Oil. 2007. Available online: http://www.bafs.da.gov.ph/bafs_admin/admin_page/pns_file/PNS-BAFS22-2007VCOrevised.pdf (accessed on 24 March 2021).
  2. Dia, V.P.; Garcia, V.V.; Mabesa, R.C.; Tecson-Mendoza, E.M. Comparative physicochemical characteristics of virgin coconut oil produced by different methods. Philipp. Agric. Sci. 2005, 88, 462–475. [Google Scholar]
  3. Marikkar, J.M.N. Differential Scanning Calorimetric Analysis of Virgin Coconut Oil, Palm Olein, and their Adulterated Blends. CORD 2019, 35, 9. [Google Scholar] [CrossRef]
  4. Rohman, A.; Che Man, Y.B. The use of Fourier transform mid infrared (FT-MIR) spectroscopy for detection and quantification of adulteration in virgin coconut oil. Food Chem. 2011, 129, 583–588. [Google Scholar] [CrossRef] [PubMed]
  5. Dayrit, F.M.; de Dios, A.C. 1H and 13C NMR for the Profiling of Natural Product Extracts: Theory and Applications. In Spectroscopic Analyses-Developments and Applications; Sharmin, E., Zafar, F., Eds.; IntechOpen: Rijeka, Croatia, 2017. [Google Scholar]
  6. Liland, K.H. Multivariate methods in metabolomics—From pre-processing to dimension reduction and statistical analysis. TrAC Trends Anal. Chem. 2011, 30, 827–841. [Google Scholar] [CrossRef]
  7. Worley, B.; Powers, R. Multivariate Analysis in Metabolomics. Curr. Metab. 2012, 1, 92–107. [Google Scholar]
  8. Westerhuis, J.A.; Hoefsloot, H.C.J.; Smit, S.; Vis, D.J.; Smilde, A.K.; van Velzen, E.J.J.; van Duijnhoven, J.P.M.; van Dorsten, F.A. Assessment of PLS–DA cross validation. Metabolomics 2008, 4, 81–89. [Google Scholar] [CrossRef]
  9. Carter, J.V.; Pan, J.; Rai, S.N.; Galandiuk, S. ROC-ing along: Evaluation and interpretation of receiver operating characteristic curves. Surgery 2016, 159, 1638–1645. [Google Scholar] [CrossRef] [PubMed]
  10. Jacob, D.; Deborde, C.; Lefebvre, M.; Maucourt, M.; Moing, A. NMRProcFlow: A graphical and interactive tool dedicated to 1D spectra processing for NMR-based metabolomics. Metabolomics 2017, 13, 36. [Google Scholar] [CrossRef] [PubMed]
  11. Chong, J.; Wishart, D.S.; Xia, J. Using MetaboAnalyst 4.0 for Comprehensive and Integrative Metabolomics Data Analysis. Curr. Protoc. Bioinform. 2019, 68, e86. [Google Scholar] [CrossRef] [PubMed]
Figure 1. 2D unsupervised exploratory PCA plots for the binary classifiers.
Figure 1. 2D unsupervised exploratory PCA plots for the binary classifiers.
Proceedings 70 00054 g001
Figure 2. PLS–DA performance of control virgin coconut oil (VCO) vs. refined bleached and deodorized coconut oil (RBDCO) indicates it is a perfect model and statistically significant. The optimal number of components or PLS latent variables is determined to be 4 denoted with a * in subplot (a). ROC curves for 100 CV (blue trace) and Single Validation (violet trace) are both equal to 1 as shown in subplot (d). Solid circle markers indicate the RBDCO class, the outline is for Control VCO class, holdout samples used in single validation are highlighted in red in subplot (e).
Figure 2. PLS–DA performance of control virgin coconut oil (VCO) vs. refined bleached and deodorized coconut oil (RBDCO) indicates it is a perfect model and statistically significant. The optimal number of components or PLS latent variables is determined to be 4 denoted with a * in subplot (a). ROC curves for 100 CV (blue trace) and Single Validation (violet trace) are both equal to 1 as shown in subplot (d). Solid circle markers indicate the RBDCO class, the outline is for Control VCO class, holdout samples used in single validation are highlighted in red in subplot (e).
Proceedings 70 00054 g002
Figure 3. Graphical summary of the results and conclusions.
Figure 3. Graphical summary of the results and conclusions.
Proceedings 70 00054 g003
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Lagurin, L.G.; Garrovillas, M.J.M.; Dayrit, F.M. The Application of 13C NMR and Untargeted Multivariate Analysis for Classifying Virgin Coconut Oil. Proceedings 2021, 70, 54. https://doi.org/10.3390/foods_2020-07718

AMA Style

Lagurin LG, Garrovillas MJM, Dayrit FM. The Application of 13C NMR and Untargeted Multivariate Analysis for Classifying Virgin Coconut Oil. Proceedings. 2021; 70(1):54. https://doi.org/10.3390/foods_2020-07718

Chicago/Turabian Style

Lagurin, Lolita G., Mark Joseph M. Garrovillas, and Fabian M. Dayrit. 2021. "The Application of 13C NMR and Untargeted Multivariate Analysis for Classifying Virgin Coconut Oil" Proceedings 70, no. 1: 54. https://doi.org/10.3390/foods_2020-07718

Article Metrics

Back to TopTop