Next Article in Journal
Increasing Lifestyle Walking by 3000 Steps per Day Reduces Blood Pressure in Sedentary Older Adults with Hypertension: Results from an e-Health Pilot Study
Next Article in Special Issue
Cardiac Magnetic Resonance, Electromechanical Activation, Kidney Function, and Natriuretic Peptides in Cardiac Resynchronization Therapy Upgrades
Previous Article in Journal
Differences in Demographics, in-Hospital Management and Short-Term Prognosis in Admissions for Acutely Decompensated Heart Failure to Cardiology vs. Internal Medicine Departments: A Prospective Study
Previous Article in Special Issue
Imaging Predictors of Left Ventricular Functional Recovery after Reperfusion Therapy of ST-Elevation Myocardial Infarction Assessed by Cardiac Magnetic Resonance
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Communication

Half-Dose versus Single-Dose Gadobutrol for Extracellular Volume Measurements in Cardiac Magnetic Resonance

1
Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Augustenburger Platz 1, 13353 Berlin, Germany
2
German Center for Cardiovascular Research (DZHK), Partner Site Berlin, 10785 Berlin, Germany
3
Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
4
Department of Infectious Diseases and Respiratory Medicine, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, 10117 Berlin, Germany
5
German Center for Lung Research (DZL), 10117 Berlin, Germany
6
Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany
*
Author to whom correspondence should be addressed.
J. Cardiovasc. Dev. Dis. 2023, 10(8), 316; https://doi.org/10.3390/jcdd10080316
Submission received: 17 May 2023 / Revised: 19 July 2023 / Accepted: 24 July 2023 / Published: 26 July 2023
(This article belongs to the Special Issue Cardiovascular Magnetic Resonance in Cardiology Practice)

Abstract

:
Background: Cardiac magnetic resonance (CMR) imaging with gadolinium-based contrast agents offers unique non-invasive insights into cardiac tissue composition. Myocardial extracellular volume (ECV) has evolved as an objective and robust parameter with broad diagnostic and prognostic implications. For the gadolinium compound gadobutrol, the recommended dose for cardiac imaging, including ECV measurements, is 0.1 mmol/kg (single dose). This dose was optimized for late enhancement imaging, a measure of focal fibrosis. Whether a lower dose is sufficient for ECV measurements is unknown. We aim to evaluate the accuracy of ECV measurements using a half dose of 0.05 mmol/kg gadobutrol compared to the standard single dose of 0.1 mmol/kg. Methods and results: From a contemporary trial (NCT04747366, registered 10 February 2021), a total of 25 examinations with available T1 mapping before and after 0.05 and 0.1 mmol/kg gadobutrol were analyzed. ECV values were calculated automatically from pre- and post-contrast T1 relaxation times. T1 and ECV Measurements were performed in the midventricular septum. ECV values after 0.05 and 0.1 mmol/kg gadobutrol were correlated (R2 = 0.920, p < 0.001). ECV values after 0.05 mmol/kg had a bias of +0.9% (95%-CI [0.4; 1.4], p = 0.002) compared to 0.1 mmol/kg gadobutrol, with limits of agreement from −1.5 to 3.3%. Conclusions: CMR with a half dose of 0.05 mmol/kg gadobutrol overestimated ECV by 0.9% compared with a full dose of 0.1 mmol/kg, necessitating adjustment of normal values when using half-dose ECV imaging.

1. Introduction

Cardiac magnetic resonance (CMR) imaging offers unique non-invasive insights into cardiac tissue composition. Expansion of the tissue extracellular volume (ECV) can be quantified using pre- and post-contrast T1 relaxation times of blood and myocardium [1,2]. Myocardial ECV has evolved as an objective and robust parameter with broad diagnostic and prognostic implications [3,4,5,6,7,8]. While gadolinium-based contrast agents generally have a favorable safety profile, and the risk of nephrogenic systemic fibrosis has been mostly eliminated by the use of group II gadolinium-based contrast agents, it is recommends to use the smallest dose possible to provide the necessary information [9,10,11]. For the gadolinium compound gadobutrol, the recommended gadolinium dose for cardiac imaging, including ECV measurements, is 0.1 mmol/kg [12,13]. This dose was optimized for late enhancement imaging, a measure of focal fibrosis. Whether a lower dose is sufficient for ECV measurements is unknown. The objective of this study is to compare ECV measurements using a gadolinium dose of 0.05 mmol/kg to a dose of 0.1 mmol/kg.

2. Materials and Methods

From a contemporary trial (NAPKON-HAP, NCT04747366, registered 10 February 2021) [14], a secondary analysis of all CMR examinations performed at our center was performed with the following inclusion criteria: Two bolus applications of contrast agent (for stress and rest perfusion), use of 0.05 mmol/kg gadobutrol (Gadovist®, Bayer Healthcare, Leverkusen, Germany) for each bolus, and acquisition of T1 maps before each bolus, as well as at the time of late enhancement imaging. 25 examinations were identified. Details on the inclusion criteria are given in the Supplementary Materials.
The secondary analysis was approved by the ethics committee of the Charité–Universitätsmedizin Berlin. All patients had previously suffered from COVID-19 and underwent research CMR to assess cardiac complications. The study protocol included quantitative analysis of myocardial stress and rest perfusion 10 min apart, requiring T1 mapping before each contrast bolus. Additionally, T1 mapping was performed 10 minutes after the second bolus for standard ECV calculations. A schematic timeline of the protocol is given in Figure 1. The full CMR protocol is shown in the Supplementary Materials.

2.1. Image Acquisition

All patients were examined with a clinical 3 Tesla MRI scanner (Ingenia, Philips Healthcare, Best, The Netherlands) equipped with a body receiver coil. T1 mapping was performed using a modified Look–Locker (MOLLI) 5s(3s)3s—scheme [15]. Typical imaging parameters were as follows: acquired voxel size = 1.97 × 2.00 × 10 mm3, reconstructed voxel size = 1.17 × 1.17 × 10 mm3, balanced SSFP readout, flip angle = 20°.

2.2. Image Analysis

Image analysis was performed offline using commercially available software (IntelliSpace Portal, Version 12.1, Philips Medical Systems Nederland B.V., Best, The Netherlands). MOLLI images were automatically corrected for in-plane motion. T1 relaxation time measurements were performed in the midventricular septum and ECV values calculated from pre- and post-contrast T1 relaxation times. T1 measurements were performed independently by two experienced readers (PD and JW, both level 3 CMR-certified).

2.3. Statistical Analysis

Statistical analysis was performed using IBM® SPSS 25® (IBM, Armonk, NY, USA) Baseline data was reported as mean ± standard deviation (SD) for interval and ratio-scaled parameters and as number and percentage for nominal and ordinal-scaled parameters. ECV measurements were compared using a Pearson correlation, a Bland–Altman analysis, and a paired t-test.

3. Results

Twenty-five patients with available T1 mapping sequences at all three time points were included. Basic demographic parameters and CMR results are given in Table 1. A Bland–Altman plot of ECV values 10 min after the first dose of 0.05 mmol/kg and 10 min after the second dose of 0.05 mmol/kg (for a total dose of 0.1 mmol/kg) is depicted in Figure 2. ECV values after 0.05 and 0.1 mmol/kg gadobutrol were correlated (r = 0.920, p < 0.001). ECV values after 0.05 mmol/kg gadobutrol had a bias of +1.1% (95%-CI [0.4; 1.4], p = 0.002) compared to 0.1 mmol/kg gadobutrol, with limits of agreement from −1.5 to 3.3%. There was no correlation between bias and hematocrit (r = −0.220, p = 0.291).

4. Discussion

We compared a half dose of 0.05 mmol/kg gadobutrol with the standard single dose of 0.1 mmol/kg for myocardial ECV measurements. The bias was +0.9 ± 1.2% (95% CI: [0.4; 1.4], p = 0.002) with limits of agreement from −1.5 to 3.3%.
These intraindividual differences are in the range of values reported in studies comparing different scanners and different protocols [16,17]. Previous studies found significantly higher ECV values after 0.1 compared to 0.2 mmol/kg gadobutrol [18,19].
Studies comparing the ECV at different time intervals after gadolinium application found constant to slightly increasing values at later time points [16,19,20]. Miller et al. found increases in ECV of 1.5%, 1.2%, and 1.0% from 2 to 20 min post-contrast for 0.1, 0.15, and 0.2 mmol/kg [19]. This is in line with our findings, as longer intervals translate to lower contrast agent concentrations due to renal elimination. Our study adds to the existing evidence that the presumptions underlying the ECV calculation might be incomplete, as the contrast dose should not influence the calculated ECV. One possible explanation would be the known non-linearity in the measurement errors of the MOLLI T1-mapping sequence [15]. Another theoretical possibility, albeit without current experimental evidence, could be a non-linearity in the contrast agent relaxivity in blood pool or myocardium.
While a dose of at least 0.1 mmol/kg should be considered standard for ECV imaging, including in patients with severe kidney disease, our data suggest that a reduced dose of 0.05 mmol/kg may still offer sufficient diagnostic accuracy to exclude large alterations in ECV.
Limitations
Due to the small sample size, our results should be considered hypothesis-generating and need to be validated in a larger cohort of with different pathologies. Our study compared a single bolus of 0.05 mmol/kg to a split bolus of two times 0.05 mmol/kg gadolinium as reference standard. McDiarmid et al. have addressed the comparability of ECV measurements between split- and single-bolus examinations and found no systematic difference [17]. Another possible confounder in our study is the use of vasodilator stress during the first contrast bolus, as heart rate and myocardial vasodilation are known to influence myocardial relaxation times. As the heart rates were very similar at the time of T1 mapping after the first and second bolus (Table 1), any differences in vasodilator effect are probably negligible.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/jcdd10080316/s1. Patient selection; Full CMR-Protocoll of the NAPKON-HAP-Trial, local Study Site (DHZB); Inter-Observer-Variablity.

Author Contributions

Conceptualization, P.D., M.W. and S.K.; methodology, P.D. and F.S.; formal analysis, P.D. and W.C.; investigation, P.D., D.H. and K.J.W.; resources, S.K. and P.S.; data curation, P.D. and F.S.; writing—original draft preparation, P.D.; writing—review and editing, S.K., F.S., D.H., W.C., K.J.W. and M.W.; visualization, P.D.; supervision, S.K.; project administration, M.W. All authors have read and agreed to the published version of the manuscript.

Funding

The NAPKON-HAP trial was funded by the BMBF (Grant FKZ 01KX2021).

Institutional Review Board Statement

The secondary analysis was conducted in accordance with the Declaration of Helsinki, and approved by the Institutional Review Board of the Charité Universitätsmedizin Berlin (EA2/214/22, 20 December 2022).

Informed Consent Statement

Patient consent for this retrospective secondary analysis was waived by the Institutional Review Board.

Data Availability Statement

The data are available upon reasonable request.

Conflicts of Interest

P.D. owns stock of Siemens and Bayer. D.H., S.K., and B.P. received support from the DZHK (German Centre for Cardiovascular Research). S.K. was supported by an unrestricted research grant from Philips Health Care. All other authors declare that they have no financial and non-financial competing interests to disclose.

References

  1. Chen, W.; Doeblin, P.; Al-Tabatabaee, S.; Klingel, K.; Tanacli, R.; Weiß, K.J.; Stehning, C.; Patel, A.R.; Pieske, B.; Zou, J.; et al. Synthetic Extracellular Volume in Cardiac Magnetic Resonance without Blood Sampling: A Reliable Tool to Replace Conventional Extracellular Volume. Circ. Cardiovasc. Imaging 2022, 15, e013745. [Google Scholar] [CrossRef] [PubMed]
  2. Ugander, M.; Oki, A.J.; Hsu, L.-Y.; Kellman, P.; Greiser, A.; Aletras, A.H.; Sibley, C.T.; Chen, M.Y.; Bandettini, W.P.; Arai, A.E. Extracellular volume imaging by magnetic resonance imaging provides insights into overt and sub-clinical myocardial pathology. Eur. Heart J. 2012, 33, 1268–1278. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  3. Doeblin, P.; Hashemi, D.; Tanacli, R.; Lapinskas, T.; Gebker, R.; Stehning, C.; Motzkus, L.A.; Blum, M.; Tahirovic, E.; Dordevic, A.; et al. CMR Tissue Characterization in Patients with HFmrEF. J. Clin. Med. 2019, 8, 1877. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Doltra, A.; Messroghli, D.; Stawowy, P.; Hassel, J.; Gebker, R.; Leppänen, O.; Gräfe, M.; Schneeweis, C.; Schnackenburg, B.; Fleck, E.; et al. Potential Reduction of Interstitial Myocardial Fibrosis with Renal Denervation. J. Am. Heart Assoc. 2014, 3, e001353. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  5. Roy, C.; Slimani, A.; De Meester, C.; Amzulescu, M.; Pasquet, A.; Vancraeynest, D.; Beauloye, C.; Vanoverschelde, J.-L.; Gerber, B.L.; Pouleur, A.-C. Associations and prognostic significance of diffuse myocardial fibrosis by cardiovascular magnetic resonance in heart failure with preserved ejection fraction. J. Cardiovasc. Magn. Reson. 2018, 20, 55. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  6. Schelbert, E.B.; Piehler, K.M.; Zareba, K.M.; Moon, J.C.; Ugander, M.; Messroghli, D.R.; Valeti, U.S.; Chang, C.-C.H.; Shroff, S.G.; Diez, J.; et al. Myocardial Fibrosis Quantified by Extracellular Volume Is Associated with Subsequent Hospitalization for Heart Failure, Death, or Both across the Spectrum of Ejection Fraction and Heart Failure Stage. J. Am. Heart Assoc. 2015, 4, e002613. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  7. Tanacli, R.; Hassel, J.H.; Gebker, R.; Berger, A.; Grafe, M.; Schneeweis, C.; Doeblin, P.; Fleck, E.; Stehning, C.; Tacke, F.; et al. Cardiac Magnetic Resonance Reveals Incipient Cardiomyopathy Traits in Adult Patients with Phenylketonuria. J. Am. Heart Assoc. 2021, 10, e020351. [Google Scholar] [CrossRef] [PubMed]
  8. Wong, T.C.; Piehler, K.; Meier, C.G.; Testa, S.M.; Klock, A.M.; Aneizi, A.A.; Shakesprere, J.; Kellman, P.; Shroff, S.G.; Schwartzman, D.S.; et al. Association between Extracellular Matrix Expansion Quantified by Cardiovascular Magnetic Resonance and Short-Term Mortality. Circulation 2012, 126, 1206–1216. [Google Scholar] [CrossRef] [PubMed]
  9. Todd, D.J.; Kay, J. Gadolinium-Induced Fibrosis. Annu. Rev. Med. 2016, 67, 273–291. [Google Scholar] [CrossRef]
  10. Woolen, S.A.; Shankar, P.R.; Gagnier, J.J.; MacEachern, M.P.; Singer, L.; Davenport, M.S. Risk of Nephrogenic Systemic Fibrosis in Patients with Stage 4 or 5 Chronic Kidney Disease Receiving a Group II Gadolinium-Based Contrast Agent: A Systematic Review and Meta-analysis. JAMA Intern. Med. 2020, 180, 223–230. [Google Scholar] [CrossRef] [PubMed]
  11. Weinreb, J.C.; Rodby, R.A.; Yee, J.; Wang, C.L.; Fine, D.; McDonald, R.J.; Perazella, M.A.; Dillman, J.R.; Davenport, M.S. Use of Intravenous Gadolinium-based Contrast Media in Patients with Kidney Disease: Consensus Statements from the American College of Radiology and the National Kidney Foundation. Radiology 2021, 298, 28–35. [Google Scholar] [CrossRef] [PubMed]
  12. Bayer Health Care Pharmaceuticals Inc. Gadavist Prescribing Information. Reference ID: 4461436. 2019. Available online: https://www.accessdata.fda.gov/drugsatfda_docs/label/2019/201277s017lbl.pdf (accessed on 19 July 2023).
  13. Messroghli, D.R.; Moon, J.C.; Ferreira, V.M.; Grosse-Wortmann, L.; He, T.; Kellman, P.; Mascherbauer, J.; Nezafat, R.; Salerno, M.; Schelbert, E.B.; et al. Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2* and extracellular volume: A consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imaging (EACVI). J. Cardiovasc. Magn. Reson. 2017, 19, 75. [Google Scholar] [PubMed] [Green Version]
  14. Schons, M.; Pilgram, L.; Reese, J.-P.; Stecher, M.; Anton, G.; Appel, K.S.; Bahmer, T.; Bartschke, A.; Bellinghausen, C.; Bernemann, I.; et al. The German National Pandemic Cohort Network (NAPKON): Rationale, study design and baseline characteristics. Eur. J. Epidemiol. 2022, 37, 849–870. [Google Scholar] [CrossRef] [PubMed]
  15. Messroghli, D.R.; Radjenovic, A.; Kozerke, S.; Higgins, D.M.; Sivananthan, M.U.; Ridgway, J.P. Modified Look-Locker inversion recovery (MOLLI) for high-resolutionT1 mapping of the heart. Magn. Reson. Med. 2004, 52, 141–146. [Google Scholar] [CrossRef] [PubMed]
  16. Kawel, N.; Nacif, M.; Zavodni, A.; Jones, J.; Liu, S.; Sibley, C.T.; A Bluemke, D. T1 mapping of the myocardium: Intra-individual assessment of the effect of field strength, cardiac cycle and variation by myocardial region. J. Cardiovasc. Magn. Reson. 2012, 14, 27. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  17. McDiarmid, A.K.; Swoboda, P.P.; Erhayiem, B.; Ripley, D.P.; Kidambi, A.; Broadbent, D.A.; Higgins, D.M.; Greenwood, J.P.; Plein, S. Single bolus versus split dose gadolinium administration in extra-cellular volume calculation at 3 Tesla. J. Cardiovasc. Magn. Reson. 2015, 17, 6. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  18. Caballeros, M.; Bartolomé, P.; González, F.; Greiser, A.; Del Barrio, L.G.; Pueyo, J.; Bastarrika, G. Effect of contrast dose in the quantification of myocardial extra-cellular volume in adenosine stress/rest perfusion cardiac magnetic resonance examinations. Acta Radiol. 2017, 58, 809–815. [Google Scholar] [CrossRef] [PubMed]
  19. Miller, C.A.; Naish, J.H.; Bishop, P.; Coutts, G.; Clark, D.; Zhao, S.; Ray, S.G.; Yonan, N.; Williams, S.G.; Flett, A.S.; et al. Response to Letter Regarding Article, “Comprehensive Validation of Cardiovascular Magnetic Resonance Techniques for the Assessment of Myocardial Extracellular Volume”. Circ. Cardiovasc. Imaging 2013, 6, 373–383. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  20. Chin, C.W.; Semple, S.; Malley, T.; White, A.C.; Mirsadraee, S.; Weale, P.J.; Prasad, S.; Newby, D.E.; Dweck, M.R. Optimization and comparison of myocardial T1 techniques at 3T in patients with aortic stenosis. Eur. Heart J. Cardiovasc. Imaging 2014, 15, 556–565. [Google Scholar] [CrossRef] [PubMed] [Green Version]
Figure 1. Timeline of the CMR protocol. Sequences not relevant to this analysis were omitted for clarity. The color scale of the T1 map after the first perfusion was manually adjusted. ECV—extracellular volume; MOLLI—modified Look–Locker inversion.
Figure 1. Timeline of the CMR protocol. Sequences not relevant to this analysis were omitted for clarity. The color scale of the T1 map after the first perfusion was manually adjusted. ECV—extracellular volume; MOLLI—modified Look–Locker inversion.
Jcdd 10 00316 g001
Figure 2. (A) Scatter plot of ECV measurements with 0.05 and 0.1 mmol/kg gadobutrol. Grey line: line of identity (y = x). Dotted blue line: regression line (R2 = 0.846, p < 0.001). (B) Bland–Altman analysis of intraindividual differences (0.1–0.05 mmol/kg) in percentage points versus mean of both measurements. Dashed line: mean difference (bias). Pointed line: limits of agreement (mean ± 1.96 SD of difference). (C,D) Representative ECV maps with (C) 0.05 mmol/kg and (D) 0.1 mmol/kg gadobutrol (created using Medis Suite MRCT 2021, Medis Medical Imaging Systems bv, Leiden, the Netherlands) for demonstrative purposes only; measurements were performed using Philips IntelliSpace Portal). ECV—extracellular volume, SD—standard deviation.
Figure 2. (A) Scatter plot of ECV measurements with 0.05 and 0.1 mmol/kg gadobutrol. Grey line: line of identity (y = x). Dotted blue line: regression line (R2 = 0.846, p < 0.001). (B) Bland–Altman analysis of intraindividual differences (0.1–0.05 mmol/kg) in percentage points versus mean of both measurements. Dashed line: mean difference (bias). Pointed line: limits of agreement (mean ± 1.96 SD of difference). (C,D) Representative ECV maps with (C) 0.05 mmol/kg and (D) 0.1 mmol/kg gadobutrol (created using Medis Suite MRCT 2021, Medis Medical Imaging Systems bv, Leiden, the Netherlands) for demonstrative purposes only; measurements were performed using Philips IntelliSpace Portal). ECV—extracellular volume, SD—standard deviation.
Jcdd 10 00316 g002
Table 1. Basic demographic parameters and CMR results.
Table 1. Basic demographic parameters and CMR results.
Total (N = 25)
Age59.4 ± 15
Sex (male)12 (52%)
Hematocrit [%]42.0 ± 4.7
LV-EDVi [mL/m²]73.0 ± 13.3
LV-EF [%]60.0 ± 6.8
RV-EDVi [mL/m²]73.6 ± 14.0
RV-EF [%]56.3 ± 8.4
Native
HR [s−1]67.8 ± 9.2
T1 myo [ms]1256 ± 39
T1 blood [ms]1859 ± 85
Half dose (0.05 mmol/kg)
HR [s−1]73.6 ± 8.3
dT [mm:ss]10:15 ± 02:06
T1 myo [ms]786.6 ± 51.7
T1 blood [ms]654 ± 74
ECV [%]27.6 ± 3.1
Full dose (0.1 mmol/kg)
HR [s−1]72.7 ± 7.6
dT [mm:ss]10:54 ± 2:10
T1 myo [ms]608 ± 39
T1 blood [ms]422 ± 48
ECV [%]26.7 ± 2.7
Myocardial (myo) and blood pool (blood) T1 relaxation times before contrast application (native), after the first perfusion (half dose, 0.05 mmol/kg), and after the second perfusion (full dose, total of 0.1 mmol/kg). dT time between the perfusion scan and the T1 mapping scan, ECV extracellular volume, HR heart rate. Continuous values as mean ± standard deviation, nominal values as number and percentage. T1 mapping and ECV mean of both readers.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Doeblin, P.; Steinbeis, F.; Witzenrath, M.; Hashemi, D.; Chen, W.; Weiss, K.J.; Stawowy, P.; Kelle, S. Half-Dose versus Single-Dose Gadobutrol for Extracellular Volume Measurements in Cardiac Magnetic Resonance. J. Cardiovasc. Dev. Dis. 2023, 10, 316. https://doi.org/10.3390/jcdd10080316

AMA Style

Doeblin P, Steinbeis F, Witzenrath M, Hashemi D, Chen W, Weiss KJ, Stawowy P, Kelle S. Half-Dose versus Single-Dose Gadobutrol for Extracellular Volume Measurements in Cardiac Magnetic Resonance. Journal of Cardiovascular Development and Disease. 2023; 10(8):316. https://doi.org/10.3390/jcdd10080316

Chicago/Turabian Style

Doeblin, Patrick, Fridolin Steinbeis, Martin Witzenrath, Djawid Hashemi, Wensu Chen, Karl Jakob Weiss, Philipp Stawowy, and Sebastian Kelle. 2023. "Half-Dose versus Single-Dose Gadobutrol for Extracellular Volume Measurements in Cardiac Magnetic Resonance" Journal of Cardiovascular Development and Disease 10, no. 8: 316. https://doi.org/10.3390/jcdd10080316

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop