Comparison of Fenton and Ozone Oxidation for Pretreatment of Petrochemical Wastewater: COD Removal and Biodegradability Improvement Mechanism

1
Tianjin Key Laboratory of Clean Energy and Pollution Control, School of Energy and Environment Engineering, Hebei University of Technology, Tianjin 300401, China
2
Tianjin Academy of Eco-Environmental Sciences, Tianjin 300191, China
*
Authors to whom correspondence should be addressed.
Separations 2022, 9(7), 179; https://doi.org/10.3390/separations9070179
Submission received: 15 June 2022 / Revised: 12 July 2022 / Accepted: 14 July 2022 / Published: 18 July 2022
(This article belongs to the Section Environmental Separations)

Abstract

:
Cost-effective pretreatment of highly concentrated and bio-refractory petrochemical wastewater to improve biodegradability is of significant importance, but remains challenging. This study compared the pretreatment of petrochemical wastewater by two commonly used chemical advanced oxidation technologies (Fenton and ozone oxidation), and the mechanisms of biodegradability improvement of pretreated wastewater were explored. The obtained results showed that in the Fenton oxidation system, the COD removal of petrochemical wastewater was 89.8%, BOD5 decreased from 303.66 mg/L to 155.49 mg/L, and BOD5/COD (B/C) increased from 0.052 to 0.62 after 60 min under the condition of 120 mg/L Fe2+ and 500 mg/L H2O2, with a treatment cost of about 1.78 $/kgCOD. In the ozone oxidation system, the COD removal of petrochemical wastewater was 59.4%, BOD5 increased from 127.86 mg/L to 409.28 mg/L, and B/C increased from 0.052 to 0.41 after 60 min at an ozone flow rate of 80 mL/min with a treatment cost of approximately 1.96 $/kgCOD. The petrochemical wastewater treated by both processes meets biodegradable standards. The GC–MS analysis suggested that some refractory pollutants could be effectively removed by ozone oxidation, but these pollutants could be effectively degraded by hydroxyl radicals (OH) produced by the Fenton reaction. In summary, compared with ozone oxidation, petrochemical wastewater pretreated with Fenton oxidation had high COD removal efficiency and biodegradability, and the treatment cost of Fenton oxidation was also lower than that of ozone oxidation.

1. Introduction

The global demand for and consumption of energy has increased rapidly in recent years. As a result, the petrochemical industry, which is an important industrial pillar of modern energy and plays an important role in the economic development of any country, has shown a continuous and steady growth trend, [1]. A large amount of highly toxic and biodegradable wastewater and waste residue will be produced in the industrial production process of petrochemical products, mainly composed of oily wastewater, phenol-containing wastewater, and high-salt wastewater, containing volatile phenol, benzene, organic acids, and other organic pollutants, which cannot be directly treated by traditional biological methods, and cause serious pollution to the natural water environment [2]. Therefore, it is necessary to pretreat petrochemical wastewater to improve its biodegradability and facilitate subsequent advanced treatment [3].
Advanced oxidation technologies (AOPs) [4] with the potential to degrade various organic pollutants mainly include the Fenton/photo-Fenton method, the photocatalytic oxidation method, the ozone oxidation method, the ultrasonic oxidation treatment method, etc. [5,6], and have been proved to be an effective wastewater treatment technology which can generate hydroxyl radicals (OH) (E0 = 2.80 V) and other radicals with strong oxidizing properties, which can effectively improve the biodegradability of effluent by high treatment efficiency and strong operability in the pretreatment of petrochemical wastewater [7,8]. Under certain pH conditions, the reaction of Fe2+ and H2O2 occurs to generate OH in a very simple and cost-effective way via Fenton oxidation [9], an advanced oxidation technology for effectively treating refractory organic wastewater, in which molecular organic pollutants are degraded to small molecular organic pollutants or mineralized to CO2 and H2O [10]. Marzie Dehboudeh et al. [11] used electro-Fenton technology to pretreat petrochemical wastewater, and then carried out advanced treatment using the activated sludge method, showing that under the conditions of pH = 3, current of 160 mA, and a H2O2 concentration of 65 mM, the COD removal rate was improved to 79%, while the B/C value increased from 0.44 to 0.776 after 30 min, which proved that the biodegradability of wastewater was greatly improved. Similarly, solar Fenton technology was used by Omid Pourehie et al. [12] to pretreat refinery wastewater, and showed that after 180 min of reaction at 694.7 mg/L H2O2, 67.3 mg/L Fe2+, and pH = 12, COD and TOC decreased to 79.6 % and 73.2 %, respectively, while the B/C values reached 0.36 to 0.62, also proving that the biochemical properties of the pretreated petrochemical wastewater were improved. Ozone is regarded as a strong oxidant with a strong oxidizing ability [13], rapid reaction, as well as being green and high efficiency, which can not only directly oxidize pollutants, but also produce OH to effectively mineralize organic pollutants, successfully realizing water purification without secondary pollution [14]. Chi-Kang Lin et al. [15] and Huangfan Ye et al. [16] treated petrochemical wastewater by combining ozone oxidation pretreatment with advanced biological activated carbon treatment, and coagulation–ozonation (ICO) integration, respectively, and effectively improved biodegradability.
Fenton oxidation and ozone oxidation degrade organic pollutants by different mechanisms. Ozone oxidation mainly reacts directly with the unsaturated bonds of organic pollutants through its own oxidizing properties, and has certain limitations that only a part of organic pollutants’ oxidation was promoted because of its selective oxidizing properties [17]. In contrast, the strong oxidizing OH, which can degrade organic pollutants non-selectively, was generated in Fenton oxidation [18]. Although the pretreatment of petrochemical wastewater by Fenton and ozone oxidation have been studied, the comparison of Fenton and ozone oxidation on the COD removal of petrochemical wastewater and biodegradability improvement mechanism is still lacking.
In this work, the petrochemical wastewater was pretreated by Fenton and ozone oxidation, and the variations in COD, BOD5, and B/C in the two systems were systematically compared. According to the GC–MS analysis, the mechanism of the improved biodegradability of the treated wastewater was explored. Additionally, the treatment costs of the two systems were compared. This study provided a technical reference for the pretreatment of bio-refractory petrochemical wastewater.

2. Materials and Methods

2.1. Materials and Real Wastewater

All chemicals used in this study were analytically pure without further purification. Main reagents include high purity oxygen (≥99.99%), ferrous sulphate heptahydrate (FeSO4·7H2O), hydrogen peroxide (H2O2) (30% w/v), concentrated sulphuric acid (98%), and sodium hydroxide (for pH adjustment), as well as dichloromethane. The primary instrumentation was a OzoniaLab 2B ozone generator, a pH meter, a Hach spectrophotometer DR2800, a magnetic stirrer, and gas chromatography-mass spectrometry (GC–MS).
High concentration production wastewater from a petrochemical wastewater treatment plant in Tianjin was used in this experiment. The wastewater samples were stored in the laboratory at 4 °C after sampling, with the initial pH of 6.26, the high COD of 2458.75 mg/L, and the B/C of 0.052, as shown in Table 1. The wastewater was used directly for the experiment without other treatment conditions.

2.2. Experimental Procedures

A 250 mL water sample of petrochemical wastewater was added to a 500 mL beaker with a certain amount of ferrous sulphate, and stirred using a magnetic stirrer at pH of 3.0, which was adjusted using H2SO4 and NaOH. A quantity of H2O2 was dropped into the solution when the ferrous sulphate was dissolved to carried out a Fenton oxidation experiment at an ambient temperature of 25 °C.
The supernatant was taken at regular intervals after a certain reaction time and analysed to determine its COD and BOD5 values, respectively, in order to observe the changes in B/C values before and after treatment. The mixture of oxygen and ozone (1 g/L) from the ozone generator was passed into the 250 mL petrochemical wastewater water sample [19]. Different intake air flows were used to oxidize petrochemical wastewater for a certain period of time in an environment of 25 °C. The COD and BOD5 values were measured by taking samples regularly.

2.3. Analysis Methods

The COD was determined using the potassium dichromate oxidation method (Hach spectrophotometer DR2800, USA) [20], and BOD5 was determined according to the State Environmental Protection Administration (SEPA) of China standard method (SEPA, 2002). Three replicate tests were performed for each sample and the results are reported as mean values with an error of less than 5%. Gas chromatography–mass spectrometry (GC–MS) [21] was used to analyze the degradation products of petrochemical wastewater. The water samples were extracted with dichloromethane and pretreated with Welchrom® PS/DVB solid phase extraction columns to enrich for organic contaminants. The samples were separated and concentrated on a column equipped with an HP-5 (30 m × 0.25 mm × 0.25 µm). The ramp-up procedure was 60 °C for 1 min, 20 °C/min to 220 °C for 1 min, and 5 °C/min to 280 °C for 4 min, and the detection spectra were retrieved qualitatively from the NIST-05 mass spectrometry database.

3. Results and Discussion

3.1. Pretreatment of Petrochemical Wastewater by Fenton Oxidation

3.1.1. Effect of Fe2+ Concentration

Figure 1 shows the effect of Fe2+ concentration on COD removal (Figure 1a), B/C values (Figure 1b), and BOD5 variation (Figure 1c) during Fenton oxidation. When the wastewater is acidified to pH = 3 that is suitable for Fenton reaction, the COD is significantly reduced, but the B/C value is 0.26, which is still less than 0.3, indicating that the biochemical properties are still low and needs to be pretreated by Fenton oxidation. The COD decreased significantly from 560.60 mg/L to 376.19 mg/L when the Fe2+ concentration increased from 20 mg/L to 120 mg/L at 300 mg/L H2O2 after 60 min. This was due to the reaction between Fe2+ and H2O2 in the wastewater to produce the strongly oxidizing OH (Equation (1)) [22], which can mineralize most organic pollutants. However, the COD increased to 504.04 mg/L when excess Fe2+ increased to 200 mg/L, because of the consumption of the generated OH (Equation (2)) (Figure 1a) [23]. The B/C value reached 0.495 when Fe2+ was 120 mg/L, greater than 0.3, and higher than other experimental groups (Figure 1b), which also has the lowest BOD5 of 186.21 mg/L (Figure 1c). It indicates that the pretreatment effect was achieved under the selected condition of 120 mg/L Fe2+ with higher biochemical properties.
Fe2+ + H2O2 → Fe3+ + OH + OH
Fe2+ + OH → Fe3+ + OH

3.1.2. Effect of H2O2 Concentration

Figure 2 shows the effect of H2O2 concentration on COD removal (Figure 2a), B/C (Figure 2b), and BOD5 (Figure 2c) during Fenton oxidation. At 120 mg/L Fe2+ and a reaction time of 60 min, the H2O2 concentration increased from 100 mg/L to 500 mg/L, and COD decreased significantly from 978.58 mg/L to 250.79 mg/L, mainly due to the oxidation of Fe2+ by H2O2 in the wastewater to produce OH (Equation (1)) [24]. However, when H2O2 was increased to 1000 mg/L, COD increased to 356.52 mg/L (Figure 2a), which was due to the consumption of the generated OH by the excess H2O2 (Equation (3)) [25]. At 500 mg/L of H2O2, the B/C value was 0.62, which was greater than 0.3 and higher than the B/C values of the other experimental groups (Figure 2b), and the BOD5 of the reacted wastewater was the smallest at 155.49 mg/L (Figure 2c). Therefore, 500 mg/L H2O2 was selected as the condition for the treatment of petrochemical wastewater by Fenton oxidation.
H2O2 + OH → H2O + O2H

3.2. Pretreatment of Petrochemical Wastewater by Ozone Oxidation

Figure 3 shows the effect of ozone flow rate on COD removal (Figure 3a), B/C values (Figure 3b), and BOD5 variation (Figure 3c) during ozone oxidation. The COD decreased from 1991.10 mg/L to 998.25 mg/L as the ozone flow rate was increased from 10 mL/min to 80 mL/min (Figure 3a) at an ozone concentration of 1 g/L after 60 min. More ozone reacting with the organic pollutants in the increasing ozone flow rate results in the decline of COD. However, since ozone is a selective oxidant and reacts slowly with organics without electron-rich parts, the COD removal effect is more obvious in the first 5 min but not high in the following time, as show in data [26]. The B/C value was 0.41 (≥0.3), with a BOD5 of 409.28 mg/L under 80 mL/min ozone flow rate (Figure 3c), indicating that high biodegradability was achieved for pretreated wastewater at this time.

3.3. Mechanisms of B/C Improvement

3.3.1. GC–MS Analysis of Wastewater

Table 2 lists the GC–MS composition analysis of wastewater, Fenton, and ozone oxidation. The wastewater composition is relatively complex and contains a variety of large organic pollutants, such as tripropylene glycol methyl ether, Di-tert-butylphenol, and large organic acids. The relative abundance of organic pollutants in the wastewater samples is shown in Figure 4a. It can be seen that the relative abundance of Di-tert-butylphenol, 2-Amino-4,5,6-methylbenzoic acid and 2-Methyl-2-Pentanol are higher, at 25.31%, 33.45%, and 15.50% respectively. This result suggests that the main microscopic composition of their organic load is large-molecule organic pollutants, from which it can be inferred the COD composition of wastewater may be large polar organic pollutants that are difficult to biodegrade, organic acids, phenols, and other organic substances [27]. Because of the high content of macromolecular organic pollution in wastewater, it is difficult or not biodegradable.

3.3.2. Biodegradability Improvement Analysis

The relative abundance of organic pollutants in the petrochemical water after the Fenton oxidation treatment for 60 min is shown in Figure 4b, and the quality of the petrochemical water was significantly improved. Some of the large molecule organic pollutants were completely removed, such as Myristic-1-13C Acid, 2-Acetyl-2-thiazoline, Guanidine, N,N’-dimethyl-. Small organic molecules, such as acetic acid and ammonium acetate were produced, and the relative abundance values of acetic acid and ammonium acetate were 30.5% and 28.14%, respectively. It can be inferred that the organic species were reduced by the Fenton oxidation treatment, and the large molecules were oxidized to small molecules by the OH generated from the Fenton reaction [28,29].
The result of ozone oxidation treatment is shown in Figure 4c. The effluent organics were mainly aromatic hydrocarbons and small molecule organics, among which the relative abundance of Di-tert-butylphenol, 2-Amino-4,5,6-methylbenzoic acid were still high, at 19.53% and 22.53%, respectively. However, it can be found that there are still many small molecules of organic matter generated in the water samples oxidized by ozone, such as the relative abundance of acetic acid at 15.34%, from which it can be inferred that ozone molecules directly attack the chemical bonds of organic matter to break them, breaking the unsaturated bonds of organic matter and changing the benzene ring into an oxygen-containing heterocyclic ring. Other methods to form small molecules of organic matter also take place.
Macromolecular organic matters are difficult to biodegrade because they are too large and, thus, cannot be injected into microorganisms, preventing their effective biodegradation. Oxidation reactions break down these large molecules into short-chain intermediates, such as small organic acids, which can enter the cell and become readily biodegradable [30].
In summary, both Fenton and ozone oxidation could effectively improve the biodegradability of pretreated petrochemical wastewater, and Fenton oxidation had a more obvious improvement effect. The above difference was mainly caused by the different process mechanisms of Fenton and ozone oxidation. OH, which generates from the Fenton reaction, mainly degrades organic pollutants through attacking double bonds in order to form carbocation, or by combining with carbocation intermediate to form additional product, capturing H+ by the C-H bond fracture of organic pollutants (Equation (4)) and degrading organic pollutants by electron transfer [31]. By contrast, O3 degrades organic pollutants through reacting with organic compounds containing unsaturated bonds or receiving electrons to replace some functional groups of organic pollutants [32]. Compared with ozone oxidation, a much higher amount of small molecular organic acids was generated in the Fenton oxidation process according to the GC–MS results, which could be attributed to the fact that O3 was a highly selective oxidant, which made it difficult to degrade organic pollutants without electron-rich fraction [33,34]. On the other hand, the generated OH can attack macromolecular organic pollutants non-selectively. Therefore, Fenton oxidation is more suitable for the pretreatment of petrochemical wastewater.
R-H + OH → H2O + R

3.4. Treatment Costs

Economic efficiency is an important indicator of the feasibility of a technology [35]. In this study, we compared the COD removal, biochemical properties (B/C), and cost analysis of the two oxidation methods after treatment.
After Fenton and ozone oxidation treatment, the COD in wastewater was significantly reduced and the B/C value reached above 0.3, indicating significant improvement in biochemical properties. It is worth nothing that the COD removal effect and biochemical properties of the Fenton oxidation treated wastewater were better than ozone oxidation (Figure 5).
The economic value of two methods was compared in terms of cost. For Fenton oxidation, the optimal dosing amounts of H2O2 and Fe2+ were 500 mg/L and 120 mg /L, respectively, while the cost of Fenton oxidation was approximately 1.77 $/kgCOD (30% H2O2 : 6.71 $/kg; ferrous sulphate heptahydrate: 4.74 $/kg); For ozone oxidation, the ozone rate of 80 mL/min is the optimal condition, and the cost is about 1.96 $/kgCOD (liquid oxygen: 149.1 $/t) (Figure 5). However, the ozone oxidation method is limited by the high operating cost of the ozone generator and treatment cost, so the cost of ozone oxidation is relatively higher than the Fenton method. In summary, in terms of the overall COD removal and biochemical analysis, the Fenton method has better economic value of than the ozone oxidation method.

4. Conclusions

In this study, Fenton and ozone oxidation were used to pretreat petrochemical wastewater, and COD removal, B/C and intermediates in above two systems were compared. Under the conditions of pH = 3, 300 mg/L H2O2, and 120 mg/L Fe2+, the COD removal of the wastewater in Fenton oxidation system reached 89.8%, the B/C value reached 0.62, and the cost was about 1.78 $/kgCOD. In the ozone oxidation system, the COD removal of petrochemical wastewater reached 59.4% and the B/C value increased to 0.41 with a treatment cost of approximately 1.96 $/kgCOD at an ozone concentration of 1 g/L and a flow rate of 80 mL/min. The GC–MS results suggested that Fenton oxidation, including the acidification process, can efficiently degrade the refractory substances in the wastewater and generate more biodegradable small molecular organic acids, which is more conducive to the improvement of biodegradability. Furthermore, the treatment cost of Fenton oxidation is also lower than that of ozone oxidation. In conclusion, Fenton oxidation is more suitable for the pretreatment of petrochemical wastewater.

Author Contributions

Conceptualization, G.R.; methodology, G.R. and S.C.; validation, G.R.; formal analysis, G.R., Z.W. (Zizhang Wei) and S.C.; investigation, S.C., X.R., R.L. and Z.W. (Zhimin Wang); resources, G.R.; data curation, G.R., Z.W. (Zizhang Wei), S.C., T.R. and X.M.; writing—original draft preparation, G.R., Z.W. (Zizhang Wei) and S.C.; writing—review and editing, G.R., S.C., T.R., Z.W. (Zhimin Wang), R.L. and X.R.; supervision, G.R. and X.M.; project administration, G.R. and X.M.; funding acquisition, G.R. and X.M. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by [National Natural Science Foundation of China] grant number [No. 22106036 and 21876042]; [Funding projects for the introduction of overseas students in Hebei Province] [C20210336]; [Natural Science Foundation of Hebei Province] [No. B2020202061 and B2019202200]; [the Ministry of Science and Technology of the People’s Republic of China] [2020YFC1808603]. The APC was funded by [National Natural Science Foundation of China] grant number [No. 22106036].

Data Availability Statement

Not applicable.

Acknowledgments

The authors gratefully acknowledge financial support for this work from National Natural Science Foundation of China (No. 22106036 and 21876042), Funding projects for the introduction of overseas students in Hebei Province (C20210336), Natural Science Foundation of Hebei Province (No. B2020202061 and B2019202200), the Ministry of Science and Technology of the People’s Republic of China (2020YFC1808603).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Biswas, T.; Banerjee, S.; Saha, A.; Bhattacharya, A.; Chanda, C.; Gantayet, L.M.; Bhadury, P.; Chaudhuri, S.R. Bacterial consortium based petrochemical wastewater treatment: From strain isolation to industrial effluent treatment. Environ. Adv. 2021, 7, 100132. [Google Scholar] [CrossRef]
  2. Hu, J.; Fu, W.; Ni, F.; Zhang, X.; Yang, C.; Sang, J. An integrated process for the advanced treatment of hypersaline petrochemical wastewater: A pilot study. Water Res. 2020, 182, 116019. [Google Scholar] [CrossRef]
  3. Wu, C.; Zhou, Y.; Wang, P.; Guo, S. Improving hydrolysis acidification by limited aeration in the pretreatment of petrochemical wastewater. Bioresour. Technol. 2015, 194, 256–262. [Google Scholar] [CrossRef]
  4. Zhang, X.-W.; Lan, M.-Y.; Wang, F.; Yi, X.-H.; Wang, C.-C. ZIF-67-based catalysts in persulfate advanced oxidation processes (PS-AOPs) for water remediation. J. Environ. Chem. Eng. 2022, 10, 107997. [Google Scholar] [CrossRef]
  5. Davarnejad, R.; Mohammadi, M.; Ismail, A.F. Petrochemical wastewater treatment by electro-Fenton process using aluminum and iron electrodes: Statistical comparison. J. Water Process Eng. 2014, 3, 18–25. [Google Scholar] [CrossRef]
  6. Liu, Z.; Demeestere, K.; Van Hulle, S. Comparison and performance assessment of ozone-based AOPs in view of trace organic contaminants abatement in water and wastewater: A review. J. Environ. Chem. Eng. 2021, 9, 105599. [Google Scholar] [CrossRef]
  7. Mohamadi, L.; Bazrafshan, E.; Rahdar, A.; Labuto, G.; Kamali, A.R. Nanostructured MgO-enhanced catalytic ozonation of petrochemical wastewater. Boletín Soc. Española Cerámica Vidr. 2020, 60, 391–400. [Google Scholar] [CrossRef]
  8. Rayaroth, M.P.; Aravindakumar, C.T.; Shah, N.S.; Boczkaj, G. Advanced oxidation processes (AOPs) based wastewater treatment-unexpected nitration side reactions-a serious environmental issue: A review. Chem. Eng. J. 2021, 430, 133002. [Google Scholar] [CrossRef]
  9. Zhao, M.; Ma, X.; Li, R.; Mei, J.; Rao, T.; Ren, G.; Guo, H.; Wu, Z. In-situ slow production of Fe2+ to motivate electro-Fenton oxidation of bisphenol A in a flow through dual-anode reactor using current distribution strategy: Advantages, CFD and toxicity assessment. Electrochim. Acta 2022, 411, 140059. [Google Scholar] [CrossRef]
  10. Ma, X.; Rao, T.; Zhao, M.; Jia, Z.; Ren, G.; Liu, J.; Guo, H.; Wu, Z.; Xie, H. A novel induced zero-valent iron electrode for in-situ slow release of Fe2+ to effectively trigger electro-Fenton oxidation under neutral pH condition: Advantages and mechanisms. Sep. Purif. Technol. 2021, 283, 120160. [Google Scholar] [CrossRef]
  11. Dehboudeh, M.; Dehghan, P.; Azari, A.; Abbasi, M. Experimental investigation of petrochemical industrial wastewater treatment by a combination of integrated fixed-film activated sludge (IFAS) and electro-Fenton methods. J. Environ. Chem. Eng. 2020, 8, 104537. [Google Scholar] [CrossRef]
  12. Pourehie, O.; Saien, J. Homogeneous solar Fenton and alternative processes in a pilot-scale rotatable reactor for the treatment of petroleum refinery wastewater. Process Saf. Environ. Prot. 2020, 135, 236–243. [Google Scholar] [CrossRef]
  13. Ahmadi, M.; Kakavandi, B.; Jaafarzadeh, N.; Babaei, A.A. Catalytic ozonation of high saline petrochemical wastewater using PAC@ FeIIFe2IIIO4: Optimization, mechanisms and biodegradability studies. Sep. Purif. Technol. 2017, 177, 293–303. [Google Scholar] [CrossRef]
  14. Bavasso, I.; Montanaro, D.; Petrucci, E. Ozone-based electrochemical advanced oxidation processes. Curr. Opin. Electrochem. 2022, 34, 101017. [Google Scholar] [CrossRef]
  15. Lin, C.-K.; Tsai, T.-Y.; Liu, J.-C.; Chen, M.-C. Enhanced biodegradation of petrochemical wastewater using ozonation and bac advanced treatment system. Water Res. 2000, 35, 699–704. [Google Scholar] [CrossRef]
  16. Ye, H.; Yang, B.; Wang, Q.; How, Z.T.; Nie, C.; Chelme-Ayala, P.; Guo, S.; Chen, C.; El-Din, M.G. Influences of integrated coagulation-ozonation pretreatment on the characteristics of dissolved organic pollutants (DOPs) of heavy oil electric desalting wastewaters. J. Environ. Manag. 2021, 300, 113756. [Google Scholar] [CrossRef]
  17. Huang, Y.; Luo, M.; Xu, Z.; Zhang, D.; Li, L. Catalytic ozonation of organic contaminants in petrochemical wastewater with iron-nickel foam as catalyst. Sep. Purif. Technol. 2018, 211, 269–278. [Google Scholar] [CrossRef]
  18. Gong, C.; Ren, X.; Han, J.; Wu, Y.; Gou, Y.; Zhang, Z.; He, P. Toxicity reduction of reverse osmosis concentrates from petrochemical wastewater by electrocoagulation and Fered-Fenton treatments. Chemosphere 2021, 286, 131582. [Google Scholar] [CrossRef]
  19. Zhang, Y.; Zuo, S.; Zhang, Y.; Ren, G.; Pan, Y.; Zhang, Q.; Zhou, M. Simultaneous removal of tetracycline and disinfection by a flow-through electro-peroxone process for reclamation from municipal secondary effluent. J. Hazard. Mater. 2019, 368, 771–777. [Google Scholar] [CrossRef]
  20. Rao, T.; Ma, X.; Yang, Q.; Cheng, S.; Ren, G.; Wu, Z.; Sirés, I. Upgrading the peroxi-coagulation treatment of complex water matrices using a magnetically assembled mZVI/DSA anode: Insights into the importance of ClO radical. Chemosphere 2022, 303, 134948. [Google Scholar] [CrossRef]
  21. Ren, G.; Zhou, M.; Zhang, Q.; Xu, X.; Li, Y.; Su, P.; Paidar, M.; Bouzek, K. Cost-efficient improvement of coking wastewater biodegradability by multi-stages flow through peroxi-coagulation under low current load. Water Res. 2019, 154, 336–348. [Google Scholar] [CrossRef]
  22. Ren, G.; Zhou, M.; Su, P.; Liang, L.; Yang, W.; Mousset, E. Highly energy-efficient removal of acrylonitrile by peroxi-coagulation with modified graphite felt cathode: Influence factors, possible mechanism. Chem. Eng. J. 2018, 343, 467–476. [Google Scholar] [CrossRef]
  23. Ren, G.; Zhou, M.; Liu, M.; Ma, L.; Yang, H. A novel vertical-flow electro-Fenton reactor for organic wastewater treatment. Chem. Eng. J. 2016, 298, 55–67. [Google Scholar] [CrossRef]
  24. Pacheco-Álvarez, M.; Benítez, R.P.; Rodríguez-Narváez, O.M.; Brillas, E.; Peralta-Hernández, J.M. A critical review on paracetamol removal from different aqueous matrices by Fenton and Fenton-based processes, and their combined methods. Chemosphere 2022, 303, 134883. [Google Scholar] [CrossRef]
  25. Sun, M.; Zou, L.; Wang, P.; Fan, X.; Pan, Z.; Liu, Y.; Song, C. Nano valent zero iron (NZVI) immobilized CNTs hollow fiber membrane for flow-through heterogeneous Fenton process. J. Environ. Chem. Eng. 2022, 10, 107806. [Google Scholar] [CrossRef]
  26. Wang, Y.; Yu, G. Challenges and pitfalls in the investigation of the catalytic ozonation mechanism: A critical review. J. Hazard. Mater. 2022, 436, 129157. [Google Scholar] [CrossRef]
  27. Yousefi, N.; Pourfadakari, S.; Esmaeili, S.; Babaei, A.A. Mineralization of high saline petrochemical wastewater using Sonoelectro-activated persulfate: Degradation mechanisms and reaction kinetics. Microchem. J. 2019, 147, 1075–1082. [Google Scholar] [CrossRef]
  28. Kakavandi, B.; Ahmadi, M. Efficient treatment of saline recalcitrant petrochemical wastewater using heterogeneous UV-assisted sono-Fenton process. Ultrason. Sonochem. 2019, 56, 25–36. [Google Scholar] [CrossRef]
  29. Li, Z.; Gu, Y.; Li, F. Heterogeneous Fenton system with dual working mechanisms for aqueous pollutants degradation. J. Environ. Chem. Eng. 2022, 10, 107686. [Google Scholar] [CrossRef]
  30. Wang, J.; Bai, Z. Fe-based catalysts for heterogeneous catalytic ozonation of emerging contaminants in water and wastewater. Chem. Eng. J. 2017, 312, 79–98. [Google Scholar] [CrossRef]
  31. Li, S.; Yang, Y.; Zheng, H.; Zheng, Y.; Jing, T.; Ma, J.; Nan, J.; Leong, Y.K.; Chang, J.-S. Advanced oxidation process based on hydroxyl and sulfate radicals to degrade refractory organic pollutants in landfill leachate. Chemosphere 2022, 297, 134214. [Google Scholar] [CrossRef] [PubMed]
  32. Issaka, E.; Amu-Darko, J.N.-O.; Yakubu, S.; Fapohunda, F.O.; Ali, N.; Bilal, M. Advanced catalytic ozonation for degradation of pharmaceutical pollutants―A review. Chemosphere 2021, 289, 133208. [Google Scholar] [CrossRef] [PubMed]
  33. Xiao, H.; Wu, J.; Wang, X.; Wang, J.; Mo, S.; Fu, M.; Chen, L.; Ye, D. Ozone-enhanced deep catalytic oxidation of toluene over a platinum-ceria-supported BEA zeolite catalyst. Mol. Catal. 2018, 460, 7–15. [Google Scholar] [CrossRef]
  34. Jin, X.; Wu, C.; Fu, L.; Tian, X.; Wang, P.; Zhou, Y.; Zuo, J. Development, dilemma and potential strategies for the application of nanocatalysts in wastewater catalytic ozonation: A review. J. Environ. Sci. 2022, 124, 330–349. [Google Scholar] [CrossRef]
  35. Pérez, J.S.; Arzate, S.; Soriano-Molina, P.; Sánchez, J.G.; López, J.C.; Plaza-Bolaños, P. Neutral or acidic pH for the removal of contaminants of emerging concern in wastewater by solar photo-Fenton? A techno-economic assessment of continuous raceway pond reactors. Sci. Total Environ. 2020, 736, 139681. [Google Scholar] [CrossRef]
Figure 1. Effect of Fe2+ concentration on (a) COD removal; (b) B/C values; (c) BOD5 variation during Fenton oxidation. Conditions are as follows: H2O2 concentration 300 mg/L; 250 mL wastewater; pH = 3.0.
Figure 1. Effect of Fe2+ concentration on (a) COD removal; (b) B/C values; (c) BOD5 variation during Fenton oxidation. Conditions are as follows: H2O2 concentration 300 mg/L; 250 mL wastewater; pH = 3.0.
Separations 09 00179 g001
Figure 2. Effect of H2O2 concentration on (a) COD removal; (b) B/C values; (c) BOD5 variation during Fenton oxidation. Conditions are as follows: Fe2+ concentration 120 mg/L; 250 mL wastewater; pH = 3.0.
Figure 2. Effect of H2O2 concentration on (a) COD removal; (b) B/C values; (c) BOD5 variation during Fenton oxidation. Conditions are as follows: Fe2+ concentration 120 mg/L; 250 mL wastewater; pH = 3.0.
Separations 09 00179 g002
Figure 3. Effect of ozone flow rate on (a) COD removal; (b) B/C values; (c) BOD5 variation during Fenton oxidation. Conditions are as follows: ozone concentration 1 g/L; 250 mL wastewater; pH = 6.26.
Figure 3. Effect of ozone flow rate on (a) COD removal; (b) B/C values; (c) BOD5 variation during Fenton oxidation. Conditions are as follows: ozone concentration 1 g/L; 250 mL wastewater; pH = 6.26.
Separations 09 00179 g003
Figure 4. Types and relative abundance of pollutants in different water samples: (a) Wastewater; (b) Fenton oxidation; (c) Ozone oxidation.
Figure 4. Types and relative abundance of pollutants in different water samples: (a) Wastewater; (b) Fenton oxidation; (c) Ozone oxidation.
Separations 09 00179 g004
Figure 5. Comparison of COD, B/C values, and treatment costs in different Fenton and ozone oxidation systems.
Figure 5. Comparison of COD, B/C values, and treatment costs in different Fenton and ozone oxidation systems.
Separations 09 00179 g005
Table 1. Petrochemical wastewater quality indicators.
Table 1. Petrochemical wastewater quality indicators.
WastewaterpHCOD (mg/L)BOD5 (mg/L)B/C
Petrochemical wastewater6.262458.75127.860.052
Table 2. GC–MS analysis of petrochemical wastewater.
Table 2. GC–MS analysis of petrochemical wastewater.
No.CompoundMolecular StructureElemental CompositiontR
(min)
[M + H] + m/zWastewaterFenton OxidationOzone Oxidation
AEthanethioamide,N,N-dimethyl- Separations 09 00179 i001C4H9NS4.173103.19
BAcetamide,N-(aminocarbony)- Separations 09 00179 i002C3H6N2O24.485102.09
CAcetic acid glacial Separations 09 00179 i003C2H4O24.66660.05
DAmmonium acetate Separations 09 00179 i004C2H7NO24.80477.08
E2-Amino-4,5,6-methylbenzoic acid Separations 09 00179 i005
Separations 09 00179 i006
Separations 09 00179 i007
C8H9NO25.378151.16
FGuanidine,N,N’-dimethyl- Separations 09 00179 i008C3H9N36.53287.12
GStearic acid Separations 09 00179 i009C18H36O29.213284.48
HPalmitic acid Separations 09 00179 i010C16H32O214.13256.42
Itripropyleneglycol methyl ether Separations 09 00179 i011C10H22O417.70206.28
JStearic acid, 2-(2-hydroxyethoxy)ethyl ester Separations 09 00179 i012C22H44O418.30372.58
KHexanamide Separations 09 00179 i013C6H13NO19.92115.17
LDi-tert-butylphenol Separations 09 00179 i014
Separations 09 00179 i015
C14H22O20.63206.32
M3,3-Dimethyl-1-(2-carboxyphenyl)triazene Separations 09 00179 i016C9H11N3O221.12193.2025
N2-Methyl-2-Pentanol Separations 09 00179 i017C6H14O21.91102.17
OMyristic-1-13C
Acid
Separations 09 00179 i018C13(13C)H28O225.85229.36
P2-Acetyl-2-thiazoline Separations 09 00179 i019C5H7NOS25.85129.18
√ indicates the presence of the pollutant in the water sample.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Cheng, S.; Ran, X.; Ren, G.; Wei, Z.; Wang, Z.; Rao, T.; Li, R.; Ma, X. Comparison of Fenton and Ozone Oxidation for Pretreatment of Petrochemical Wastewater: COD Removal and Biodegradability Improvement Mechanism. Separations 2022, 9, 179. https://doi.org/10.3390/separations9070179

AMA Style

Cheng S, Ran X, Ren G, Wei Z, Wang Z, Rao T, Li R, Ma X. Comparison of Fenton and Ozone Oxidation for Pretreatment of Petrochemical Wastewater: COD Removal and Biodegradability Improvement Mechanism. Separations. 2022; 9(7):179. https://doi.org/10.3390/separations9070179

Chicago/Turabian Style

Cheng, Siyu, Xiaomeng Ran, Gengbo Ren, Zizhang Wei, Zhimin Wang, Tiantong Rao, Ruixuan Li, and Xiaodong Ma. 2022. "Comparison of Fenton and Ozone Oxidation for Pretreatment of Petrochemical Wastewater: COD Removal and Biodegradability Improvement Mechanism" Separations 9, no. 7: 179. https://doi.org/10.3390/separations9070179

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop