Next Article in Journal
Determination of N-Paraffins Content in Crude Oil via Near-Infrared Spectroscopy Associated with Chemometric Approaches
Next Article in Special Issue
Reinventing Processes for Sustainability via Process Intensification and Integration
Previous Article in Journal
Surrounding Rock Deformation Mechanism and Control Technology for the Roadway in the Fault-Disturbed Zone under Special-Shaped Coal Pillars
Previous Article in Special Issue
Enhancing Mean-Variance Mapping Optimization Using Opposite Gradient Method and Interior Point Method for Real Parameter Optimization Problems
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Experimental Evaluation of Chemical Reactions Involved in Ultrasonic-Assisted Absorption of Bulk CO2

1
CO2 Research Center (CO2RES), Department of Chemical Engineering, Universiti Teknologi PETRONAS, Seri Iskandar 32610, Perak, Malaysia
2
Biological and Chemical Engineering Department, Faculty of Technical Science, Aarhus University, Nørreborgade 44, 8000 Aarhus, Denmark
*
Author to whom correspondence should be addressed.
Processes 2023, 11(12), 3266; https://doi.org/10.3390/pr11123266
Submission received: 28 October 2023 / Revised: 12 November 2023 / Accepted: 16 November 2023 / Published: 22 November 2023

Abstract

:
As the most mature natural gas sweetening process, absorption has always been improved to meet the separation requirement. Recently, ultrasonic irradiation has been proposed as a technique that can intensify CO2 absorption. However, further studies are still required, particularly focusing on the sonochemical effect. Since the influence of the sonochemical effect on the reaction pathway is still debatable, attention must be given to verifying the influence of ultrasonic irradiation on the chemical reactions of CO2 absorption. Hence, this work aims to evaluate the influence of  O H ˙  radicals generated by the sonochemical effect on the chemical reactions involved during CO2 absorption using promoter-free methyldiethanolamine (MDEA). For the evaluation, various samples under irradiated and non-irradiated conditions are analyzed using the HPLC characterization technique. The results show that the hypothesis of changing the reaction pathway due to the presence of the sonochemical effect is invalid. However, it can accelerate the generation of hydroxyl radicals ( O H ˙ ) via water sonolysis. Thus, the origin of sonochemistry in aqueous solutions is defined as water sonolysis. The analysis of the CO2 absorption rate also demonstrates the presence of accelerated chemical reactions (contributed by the  O H ˙  radicals), which could potentially make the slow kinetic MDEA more practical for industrial application.

Graphical Abstract

1. Introduction

The demand for natural gas is predicted to rise by more than 60% between now and 2040. Depending on the geological condition of the reservoir, the raw natural gas has a wide range of gases, including methane, heavier hydrocarbons such as ethane, propane, isobutene, normal butane, and a substantial amount of impurities such as CO2, H2S, and CO [1]. Removing acidic impurities from natural gas, especially CO2, is a vital step toward further utilization of this energy source. Such CO2 elimination in both on/offshore natural gas wells can be achieved by developing carbon capture and storage processes that permit the mitigation and utilization of CO2.
Currently, absorption, especially chemical absorption, is the most developed separation process widely used to capture CO2 from raw natural gas [2]. Nevertheless, this process still suffers from various drawbacks, including high energy consumption for solvent regeneration, solvent loss, equipment corrosion, and large column sizes [3,4]. These disadvantages pose various technical and financial challenges to the CO2 absorption process, necessitating the search for intensification techniques. Such process intensification techniques can reduce the size of conventional absorption columns, decrease the equipment capital cost, and make CO2 absorption more feasible. Available techniques to intensify the mass transfer of the absorption process include packed bed columns (PB), rotating packed bed columns (RPB), hollow fiber membrane contactors (HFMC), bubble columns (BC), microchannel reactors (MC), and ultrasonic irradiation [5,6]. Among them, ultrasonic irradiation is a novel technique requiring extensive investigations before industrial scaleup.
In general, ultrasonic irradiation is expressed as sound waves with frequencies higher than the upper limit of human hearing ability, ranging from 20 kHz to 500 MHz. Depending on the applied frequency and the presence of the sonophysical and sonochemical effects, this technique has the potential to be used in different research areas, including food technology [7], cleaning [8], medical treatment [9], crude oil upgrading [10], synthesis of nanomaterials [11,12], and enhancement of multiphase reactions [13,14]. However, using high-frequency ultrasonic irradiation in the natural gas purification field is limited, particularly as a potential intensification technique for CO2 absorption. The concept of using ultrasonic irradiation in the CO2 absorption process was first proved by Tay et al. (2017) [15,16,17]. They investigated the effect of high-frequency ultrasonic irradiation on the CO2 absorption performance of a batch lab-scale reactor. Three different solvents were tested, including water, monoethanolamine (MEA), and potassium carbonate (K2CO3). The results showed a remarkable rise in the CO2 absorption rate by utilizing ultrasonic irradiation with a frequency of 1.7 MHz. They stated that ultrasonic irradiation can improve CO2 absorption performance because of the sonochemical and sonophysical effects. However, particular attention was given to the sonophysical effects. After proving the concept, the focus switched to the continuous mode. Hence, Yusof et al. (2019) developed a novel continuous high-frequency ultrasonic contactor system for the CO2 absorption process [18]. They investigated the effect of different operating parameters on the ultrasonic-assisted CO2 absorption from natural gas using water. They mentioned that the continuous ultrasonic contactor system for CO2 absorption performed better than other contactors. According to their results, the continuous ultrasonic contactor system showed the highest mass transfer coefficient (0.037 s−1) between the other contactors, including the bubble column, stirred vessel, and counter-current packed column. They did not, however, address the significance of sonophysical and sonochemical effects on such improvements [18]. To suit the industrial mode, they also evaluated the performance of the proposed continuous system with MEA. The influence of various operating parameters on the overall mass transfer coefficient was evaluated. They reported that at the optimized conditions for the CO2-MEA system, the high-frequency ultrasonic absorption system could intensify the mass transfer up to 12 times compared to the conventional packed bed column. They concluded that the sonophysical effects are mainly responsible for the enhanced CO2 absorption process in the continuous high-frequency ultrasonic reactor [19]. The effects of different absorbents, including diethanolamine (DEA), sodium hydroxide (NaOH), and sodium carbonate (Na2CO3), on ultrasound-assisted CO2 absorption were investigated in the study conducted by Marjanian et al. (2021) [20]. They stated that the extent of improving CO2 absorption performance in the ultrasonic-assisted absorption system depends on the absorbent type.
As a way forward to maturing this technique, more fundamental research on CO2 absorption performance utilizing other commercial chemical absorbents and focusing on sonochemical effects was required. Therefore, in our previous research [21], attention was given to MDEA as a chemical absorbent with a high inherent CO2 absorption capacity but slow absorption kinetics with CO2. The influence of different operating parameters on CO2 absorption performance in an ultrasonic-assisted batch reactor was evaluated using MDEA in single and blended forms. The potential of the ultrasonic-assisted reactor was then further elucidated through a comparative analysis with magnetic stirring and non-irradiated conditions. The findings demonstrated that the CO2 absorption rate in the ultrasonic-assisted reactor was approximately 28 and 52 times higher than in the stirred reactor and the non-irradiated condition, respectively, when 50% promoted-free MDEA was utilized. Even with the addition of 5% piperazine (PZ), the ultrasonic-assisted CO2 absorption system outperformed other systems. Compared to the magnetic stirred reactor, the CO2 absorption rate in this case was 17 times higher. Furthermore, compared to the non-irradiated condition, the CO2 absorption rate was 54 times higher. Both sonochemical and sonophysical effects were responsible for the increase in the CO2 absorption rate [21]. However, as the role of the sonochemical effect on the improvement of the CO2 absorption process in the ultrasonic-assisted reactor was not yet elucidated, our recent study aimed to parametrically quantify the sonochemical effect during CO2 absorption in the ultrasonic-assisted reactor using promoter-free MDEA. A novel indirect method was implemented to identify  O H ˙  radicals as the representative of the sonochemical effect. Terephthalic acid (TA) was selected as a chemical probe for detecting and scavenging  O H ˙  radicals during the CO2 absorption using promoter-free MDEA. Subsequently, the quantification was performed via scavenging of  O H ˙  radicals using TA. Despite the parametric quantification, the role of the sonochemical effect on the chemical reactions involved in CO2 absorption has not yet been investigated.

2. Theory

In general, the CO2 absorption process contains three key steps, including vapor-liquid mass transfer, liquid-liquid mass transfer, and liquid chemical reaction [22]. By applying high-frequency ultrasonic irradiation, all these steps can be influenced due to the presence of sonophysical and sonochemical effects. Figure 1 illustrates the sonophysical and sonochemical effects induced by high-frequency ultrasonic irradiation during the CO2 absorption process.
According to Figure 1, atomization, acoustic streaming, liquid fountain formation, and heating are the main sonophysical effects induced by high-frequency ultrasonic irradiation during the CO2 absorption process. The sonophysical effects can improve mass transfer by adequately mixing, lowering mass transfer resistance in the liquid phase, and increasing the effective interfacial areas between the gas and liquid phases [15,16]. In contrast, the sonochemical effect is caused by a phenomenon known as acoustic cavitation [19]. Cavitation involves various steps. The three main steps of cavitation are formation (nucleation), bubble growth (expansion) during the cycles until reaching a critical size, and violent collapse in the liquid bulk. These steps are repeated consistently. In the formation step, if the ultrasonic intensity is high enough to surpass the liquid’s tensile strength, there comes a point at which intermolecular forces can no longer hold the molecular structure together. Cavitation nuclei form in the liquid phase as a result of this point [23,24]. The formed microbubbles may grow rapidly if the ultrasonic intensity is sufficiently strong. This step is recognized as an expansion [25]. The implosion step happens when the cavitation bubble becomes so dense that it cannot continue absorbing energy to sustain itself. As a result, the surrounding liquid rushes into it, causing an implosion [23,26]. Each bubble functions as a core when implosion occurs, producing energy that increases the temperatures and pressure on a microscale. Due to inducing extremely high local temperature and pressure, the collapsing bubbles can create an unusual environment for chemical reactions by forming highly reactive radical species [23,27].
According to the hotspot theory, a chemical reaction happening in an ultrasonic-assisted system is a heterogeneous reaction in which reactive species are generated from the cavitation bubble. In this theory, three regions are anticipated for the incidence of chemical reactions, including (1) a hot gaseous nucleus or thermolytic zone, (2) an interfacial area having a radial temperature gradient and a local radical density, and (3) the solution bulk at ambient temperature. These three regions are shown in Figure 2.
In the first region, which is a hot gaseous nucleus, the extreme conditions created by collapse trigger bond breakage of the presented vapors and gases within the bubble nucleus, leading to the generation of free radicals, particularly OḢ radicals. The formed OḢ radicals can either react with each other to form new molecules and radicals or diffuse into the liquid bulk [24]. The second region is the liquid shell around the imploding cavity, which is estimated to heat up to approximately 2000 K during implosion. Combustion and radical reactions (including OḢ generated from H2O decomposition) occur in this solvent layer around the hot bubble. In the liquid bulk, as the last region, there is no direct sonochemical activity, but subsequent reactions with ultrasonically produced intermediates may occur. Furthermore, a limited number of radicals generated in the cavities or at the interface may move into the bulk liquid phase and react with the substrate to form new products [24,28]. Hence, there might be some differences in the reaction pathways in the ultrasonic-assisted system compared to the conventional system. Due to the generation of OḢ radicals, there is a hypothesis that the sonochemical effect is capable of speeding up or changing the reaction pathway of the CO2 absorption process in the high-frequency ultrasonic-assisted system. The generated OḢ radicals could be the cause of the ultrasonic-assisted system’s improved performance, as summarized in Table 1. However, the role of the sonochemical effect on the chemical reaction of CO2 absorption has not been discussed. Thus, further studies are substantial to investigate the role of the sonochemical effect on the reaction pathway during ultrasonic-assisted CO2 absorption.

3. Methodology

3.1. Materials

The materials used in this work and the specifications provided by their suppliers are presented in Table 2.

3.2. Experimental Setup

The schematic of the ultrasonic-assisted CO2 absorption system is shown in Figure 3. The reactor was fabricated using stainless steel, operating in the batch absorption configuration. The reactor consisted of a top cover and a cylindrical body. The volume of the reactor, inner diameter, and height were 250 mL, 5 cm, and 17.8, respectively. The temperature sensor, pressure sensor, gas inlet and outlet, and pH probe were on the top cover in five different ports. For direct contact with the solution, the transducer, which had a 1.5 cm diameter and a frequency of 1.7 MHz, was positioned at the bottom of the ultrasonic reactor. It should be noted that the transducer converts the electrical power into ultrasonic irradiation using the calorimetric method [32]. The procedure for conducting the CO2 absorption experiments is comprehensively described in our previous research paper [21].

3.3. Procedure of Reaction Pathway Evaluation

Various samples needed to be analyzed to provide sufficient analytical data for identifying the role of the sonochemical effect, in particular OḢ radicals, on the reaction pathway. The HPLC characterization technique was implemented for analysis. The analysis was performed by evaluating the significance of OḢ radicals during the CO2 absorption process using promoter-free MDEA. In line with this aim, in-vitro detection of OḢ radicals was performed. TA was used as the OḢ radical scavenger. The optimum mass concentration of TA to be used in the subsequent experiments was 10 wt%. It should be noted that the optimum mass concentration of TA is defined as the concentration necessary to trap all the generated  O H ˙  radicals from the reaction mixture [33,34], which can subsequently inhibit the CO2 absorption process without affecting the reaction pattern. The samples were divided into four groups, with each group being tested three times under two different conditions, including irradiated and non-irradiated. The samples are listed in Table 3. For each sample, the HPLC chromatograms were analyzed to identify the stable chemical compounds formed under different conditions. The identification of chemical compounds was performed based on the standard verification method. Subsequently, the concentration of the identified chemical compounds was calculated based on the HPLC peak area and HPLC calibration curves. Finally, to verify the mechanism, the reaction pathway was evaluated by comparing concentration variations between irradiated and non-irradiated samples.

3.4. HPLC Equipment and Chromatographic Conditions

As mentioned in Section 3.3, the analysis of the scavenged  O H ˙  radicals were performed by the HPLC instrument (Model Agilent series 1100). A YMC-Pack Polymer C18 reverse phase column (250 mm × 6.0 mm ID) was selected. The column was carefully washed with a mixture of water and acetonitrile (60:40) 1 h before and 2 h after use. The eluent was a mixture of 100 mM Na2HPO4 and 100 mM NaOH (ratio 60:40 at a pH of 12). The eluent flow rate was 0.6 mL·min−1, and the analysis was conducted at 20 °C. The injection volume of the sample was 20 µL, and the UV light at a wavelength of 215 nm was used as the detector. For calibration purposes, two sets of standards with different concentrations were freshly prepared. The first set of calibration standards consisted of an aqueous solution of MDEA with concentrations of 10, 20, 30, 40, and 50 wt%. Since TA is poorly soluble in water, the second set of standards consisted of various mass concentrations of TA dissolved in the 50% aqueous MDEA solution. TA concentrations were 1, 3, 5, 7, 9, and 11 wt%. The different sets of the prepared standards were then injected into the HPLC system. For each set of calibration standards, the relationship between the peak area of the compound and its concentration was evaluated. The calibration curve for each set of standards was then plotted. Subsequently, the coefficient of determination (R2) was obtained from the regression line. The calibration curves for MDEA and TA with the respective R2 values of 0.99 and 0.98 are presented in Figure 4.

4. Results and Discussion

As mentioned, four different groups of liquid-phase samples were chosen for analysis. Each group was examined under irradiated and non-irradiated conditions. Then the samples were characterized by the HPLC analytical technique with UV detection. According to the obtained HPLC data, stable chemical compounds formed under irradiated and non-irradiated conditions were identified. The final concentrations of the identified chemical compounds were calculated using the HPLC peak area and the calibration curves. The reaction pathway was finally evaluated by comparing the detected peaks, which represent the chemical compounds and their concentration variations between the two testing conditions. The results of the HPLC-UV characterization of the selected samples are as follows.

4.1. HPLC Analysis of Aqueous MDEA Solution

Two samples containing 50 wt% MDEA in the aqueous form were injected into the HPLC system. The ultrasonic irradiation was applied to the first sample (A1) but not to the second (A2). The ultrasonic power and the frequency were 12.36 W and 1.7 MHz, respectively. The chromatogram of these samples is shown in Figure 5. Firstly, the straight baseline was observed in both chromatograms, indicating the accuracy of the results. Moreover, one peak was observed in each chromatogram, representing the MDEA. The identity of the detected peak was validated by comparing it to previously tested MDEA standards. The obtained HPLC data is summarized in Table 4. The final concentrations of MDEA in both samples were determined based on the peak area and the HPLC calibration curve for MDEA, as shown in Figure 6. The same aqueous MDEA solution with the approximate initial concentration of 50 wt% was used for both samples. The results show insignificant changes in the final concentration and indicate the stability of MDEA molecules once irradiated by high-frequency ultrasonic irradiation. Such an insignificant rise in the concentration of the irradiated sample might be due to the possibility of minor evaporation of the water content of the aqueous solution during the high-frequency ultrasonic irradiation [35,36]. In particular, the evaporation is induced by the heating effect of ultrasonic irradiation. When the ultrasonic wave transmits to the liquid phase, some of the ultrasound energy is converted to heat energy, causing the liquid phase to heat up and evaporate. However, external cooling systems like an air fan, cooling water jacket, cooling coil, or water bath can maintain the liquid temperature and minimize evaporation [37].

4.2. HPLC Analysis of Aqueous MDEA Solution Blended with TA

Similar to the previous step, two samples in the aqueous form containing 50 wt% MDEA blended with 10 wt% of TA were prepared for HPLC analysis. The ultrasonic irradiation was applied to the first sample (B1) but not to the second (B2). The HPLC chromatogram of these samples is shown in Figure 7.
According to Figure 7, two peaks were observed in each chromatogram, identified as TA and MDEA for the irradiated sample. However, it was expected to observe one more peak representing 2-hydroxyterephthalic acid (HTA), but due to the low concentration, the peak shape is a bit flat and cannot be observed. The concentrations of the identified peaks were determined based on the peak area, as mentioned in Table 5, and the HPLC calibration curve for MDEA and TA. The results are presented in Figure 8. Since the same peaks were detected in both samples and no additional peaks were observed, it can be stated that ultrasonic irradiation did not change the structure of the mixture. Moreover, according to the results, no significant changes in the concentrations of the MDEA compound in both irradiated and non-irradiated samples were observed. However, the concentration of TA compound in the irradiated sample was lower than in the non-irradiated sample, indicating the presence of more OḢ radicals under the irradiated condition. These findings confirmed the stability of MDEA molecules; thus, it can be stated that the possibility of breaking the chemical bond of the MDEA molecule with high-frequency ultrasonic irradiation is negligible. In other words, the generation of OḢ radicals scavenged by TA might be due to the dissociation of the water content of the aqueous solution [38,39].
The above-mentioned assumption can also be discussed from a molecular point of view. According to the molecular structure of MDEA, there are two O-H functional groups in the 1 and 1’ positions, as shown in Figure 9. In each position, the O-H functional group is attached to a carbon atom, which is sterically hindered. Additionally, when atoms are close together, the energy of the covalent bonds that keep the atoms together in the molecule increases [40,41]. Due to the increased energy, breaking the chemical bond of the O-H functional groups of the MDEA molecule for generating OḢ radicals is more complex than in water, which is not considered a steric hindrance. Thus, the formation of OḢ radicals can be mainly attributed to the dissociation of water rather than MDEA.

4.3. HPLC Analysis of the CO2 Absorbed into the Aqueous MDEA Solution

The CO2 absorption into the aqueous MDEA solution was also analyzed by HPLC under two different conditions to provide sufficient information for elucidating the role of the sonochemical effect on the chemical reactions. In the first approach, the CO2 absorption process using promoter-free MDEA was performed in an ultrasonic-assisted reactor (C1). Whereas in the second approach, the CO2 absorption process was carried out under the non-irradiated condition (C2). For both approaches, the experimental conditions were the optimized conditions obtained in our previous research work [21]. After the absorption process, the samples were injected into the HPLC equipment for analysis. The HPLC chromatogram and information of detected peaks are presented in Figure 10, and Table 6, respectively. Based on the retention time of the MDEA standards, one peak was identified as MDEA, but the other remained unidentified. The unknown peak might be any stable intermediate formed during the CO2 absorption process utilizing MDEA aqueous solution, which can be identified further using the GC-MS characterization technique. However, the unknown peak was detected at a similar retention time in both testing samples, indicating that no change had happened to the sample after inducing ultrasonic irradiation. Therefore, due to the similarity of the presented peaks, it can be stated that no unexpected changes in terms of forming new chemical compounds occurred during CO2 absorption into an aqueous MDEA solution in an ultrasonic-assisted reactor. According to the obtained data, the concentration of MDEA, as the identified peak, was calculated. Figure 11 shows the MDEA concentration changes for irradiated and non-irradiated samples after absorbing 11 bars of CO2. The results showed no significant difference in the MDEA concentration of both samples, indicating that a similar amount of absorbent was consumed during the CO2 absorption process.

4.4. HPLC Analysis of the CO2 Absorbed into the Aqueous MDEA Solution Blended with TA

The CO2 absorption process utilizing an aqueous MDEA solution was further investigated by HPLC in the presence of TA. The tests were performed under irradiated (D1) and non-irradiated (D2) conditions using a 50 wt% aqueous solution of MDEA mixed with 10 wt% TA. After the CO2 absorption process, the samples were injected into the HPLC system. As previously stated, the operating conditions were set at the optimized experimental conditions for promoter-free MDEA. The HPLC chromatogram of the samples and the information about the detected peaks are presented in Figure 12 and Table 7, respectively.
As can be seen, in each chromatogram, three peaks were observed. According to the retention time and referring to the calibration standards, the MDEA and TA peaks were identified. But the second peak in both samples could not be identified. Nevertheless, the retention time of the unknown peak was almost similar in both samples, indicating the formation of an identical compound. Due to the similarity of the observed peaks in both irradiated and non-irradiated conditions, it can be stated that the CO2 absorption performed in almost the same way. In both conditions, the concentrations of the identified peaks, MDEA and TA, were calculated based on the respective calibration curves. Figure 13 shows the concentration variation of the identified peaks for irradiated and non-irradiated samples. For the sample tested under the non-irradiated condition, the concentration of TA is approximately equal to the initial concentration of 10 wt%, indicating that the formation of OḢ radicals is not feasible under the non-irradiated condition. Conversely, the variation in TA concentration in the irradiated sample confirmed the presence of OḢ radicals and their involvement during the CO2 absorption process. Furthermore, there were no significant differences in MDEA concentrations for the irradiated sample compared to the scavenger-free CO2 absorption process (C1). The insignificant concentration variations of MDEA support the idea of MDEA molecular stability versus water molecules under high-frequency ultrasonic irradiation. Thus, the scavenged OḢ radicals during the CO2 absorption originated insignificantly from the breakage of the MDEA chemical bonds. In other words, the formation of OḢ radicals seems to be predominantly caused by the dissociation of water molecules, which may eventually assist in the CO2 absorption process.

4.5. Evaluation of the Reaction Pathway

According to the HPLC characterization results of the samples, no new chemical compounds were detected during the CO2 absorption process utilizing MDEA in the high-frequency ultrasonic-assisted reactor. Thus, the hypothesis of changing the reaction pathway due to the presence of the sonochemical effect is invalid. The stability of MDEA molecules compared to water molecules explains the non-alteration in the reaction pathway despite inducing high frequency and high power ultrasonic irradiation. It means that the applied ultrasonic energy can readily break the water molecules but not the MDEA molecules. Even if the MDEA molecules partially break down and release OḢ radicals, they would immediately react with the available OḢ radicals and reestablish themselves since they are in an irradiated aqueous solution with abundant OḢ radicals. Thus, it can be stated that despite the presence of the sonochemical effect, the reaction of CO2 absorption into aqueous MDEA solution can still be explained by the conventional reaction pathway shown in Figure 14.
According to the conventional reaction pathway, MDEA, as a tertiary alkanolamine, cannot directly react with CO2 as it has no hydrogen atom attached to the nitrogen atom. It is worth noting that the presence of hydrogen atoms is essential for a direct reaction with CO2. Due to the lack of hydrogen and, consequently, proton, MDEA can provide a sink for the hydrogen ions produced when CO2 hydrolysis in water to form bicarbonate. The complete mechanism includes three reactions [42]:
C O 2 + H 2 O H C O 3 + H +
C O 2 + O H H C O 3
M D E A + C O 2 + H 2 O M D E A H + + H C O 3
Therefore, while the sonochemical effect cannot change the reaction pathway, in the aqueous solutions, it can accelerate the generation of OḢ radicals via water sonolysis. In particular, for the above reactions, such acceleration could alter the slow formation of bicarbonate, resulting in a faster rate of CO2 absorption.

4.6. Significance of Ultrasonic Irradiation on CO2 Absorption Rate

The sonochemical effect can significantly influence the rate of CO2 absorption. To clarify its influence, the CO2 absorption rate was assessed in the absence and presence of TA (as the scavenger for OḢ radicals) operating under irradiated and non-irradiated settings. The basis of rate determination is explained in our previous research work [21]. The findings are shown in Figure 15. The absorption rate under the non-irradiated condition remained approximately unchanged in both the presence and absence of TA. Whereas for the irradiated condition, it changed considerably. In an irradiated setting and without TA, the CO2 absorption rate was about 4.20 mol/h. However, the CO2 absorption rate was reduced to 0.75 mol/h by adding TA. The 5.6-fold reduction can explain the significance of the sonochemical effect on absorption rate enhancement. Thus, despite the non-alteration of the reaction pathway, the generated OḢ radicals induced by the sonochemical effect can significantly influence the CO2 absorption rate.

5. Conclusions

Ultrasonic irradiation is a novel technique that can intensify the CO2 absorption process because of the sonochemical and sonophysical effects. The fundamental principles of sonophysical and sonochemical effects in assisting CO2 absorption have been proven recently. Nevertheless, more detailed research is still needed to light up the path of commercial use of ultrasonic-assisted CO2 absorption systems. Particularly, it is crucial to investigate the significance of the sonochemical effects on the chemical reactions of the CO2 absorption process. It is hypothesized that the sonochemical effect might affect the chemical reactions either by accelerating or altering them. Therefore, to assess the above-mentioned assumptions, the role of the sonochemical effect on the reaction pathway was evaluated by analyzing various samples. The sample analysis was performed by evaluating the importance of OḢ radicals during the CO2 absorption process using promoter-free MDEA. Moreover, TA was used as the potential OḢ radical scavenger. For each sample, chemical components from the liquid phase were analyzed by HPLC and compared under irradiated and non-irradiated conditions. The comparison aimed to find possible evidence of the sonochemical effect’s capability to change the reaction pathway. The similarity of the comparative results claimed that the sonochemical effect could not change the reaction pathway. Thus, the admitted origin of sonochemistry in aqueous solutions was water sonolysis, which could generate the OḢ radicals and subsequently accelerate the CO2 absorption process.

Author Contributions

Conceptualization, K.K.L. and F.S.; writing—original draft preparation, K.K.L. and F.S.; writing—review and editing, K.K.L. and B.P.; supervision, K.K.L.; funding acquisition, K.K.L. All authors have read and agreed to the published version of the manuscript.

Funding

The research was funded by the YUTP-PRG project (015PBC-013).

Data Availability Statement

Data are contained within the article.

Acknowledgments

The authors wish to acknowledge the technical support provided by CO2 Research Centre (CO2RES), Universiti Teknologi PETRONAS, Malaysia.

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

barPressure unit
BCBubble column
COCarbon monoxide
CO2Carbon dioxide
DCDisk column
DEADiethanolamine
HFMCHollow fiber membrane contactor
HFUAHigh-frequency ultrasonic assisted
HPLCHigh-performance liquid chromatography
H2SHydrogen sulfide
IDInner diameter
KTemperature unit, Kelvin
K2CO3Potassium carbonate
mAUmilli-Absorbance Unit
MMolar
MCMicrochannel
MEAMonoethanolamine
MHzMegahertz, frequency unit
MDEAMethyl diethanolamine
NaOHSodium hydroxide
Na2CO3Sodium carbonate
nmNanometer, wavelength unit
  O H ˙ Hydroxyl radical
PBPacked bed
RPBRotating packed bed
RTRetention time
TATerephthalic acid
TTemperature
UVUltraviolet spectroscopy
WWatt, ultrasonic power unit
WWCWetted wall column

References

  1. Shokrollahi, F.; Lau, K.K.; Partoon, B.; Smith, A.M. A review on the selection criteria for slow and medium kinetic solvents used in CO2 absorption for natural gas purification. J. Nat. Gas Sci. Eng. 2022, 98, 104390. [Google Scholar] [CrossRef]
  2. Rufford, T.E.; Smart, S.; Watson, G.C.; Graham, B.F.; Boxall, J.; Da Costa, J.D.; May, E.F. The removal of CO 2 and N 2 from natural gas: A review of conventional and emerging process technologies. J. Pet. Sci. Eng. 2012, 94–95, 123–154. [Google Scholar] [CrossRef]
  3. Kenarsari, S.D.; Yang, D.; Jiang, G.; Zhang, S.; Wang, J.; Russell, A.G.; Wei, Q.; Fan, M. Review of recent advances in carbon dioxide separation and capture. RSC Adv. 2013, 3, 22739–22773. [Google Scholar] [CrossRef]
  4. MacDowell, N.; Florin, N.; Buchard, A.; Hallett, J.; Galindo, A.; Jackson, G.; Adjiman, C.S.; Williams, C.K.; Shah, N.; Fennell, P. An overview of CO2 capture technologies. Energy Environ. Sci. 2010, 3, 1645–1669. [Google Scholar] [CrossRef]
  5. Tay, W.H.; Lau, K.K.; Lai, L.S.; Shariff, A.M.; Wang, T. Current development and challenges in the intensified absorption technology for natural gas purification at offshore condition. J. Nat. Gas Sci. Eng. 2019, 71, 102977. [Google Scholar] [CrossRef]
  6. Tan, L.S.; Shariff, A.M.; Lau, K.K.; Bustam, M.A. Factors affecting CO 2 absorption efficiency in packed column: A review. J. Ind. Eng. Chem. 2012, 18, 1874–1883. [Google Scholar] [CrossRef]
  7. Bhargava, N.; Mor, R.S.; Kumar, K.; Sharanagat, V.S. Advances in application of ultrasound in food processing: A review. Ultrason. Sonochem. 2021, 70, 105293. [Google Scholar] [CrossRef] [PubMed]
  8. Aktij, S.A.; Taghipour, A.; Rahimpour, A.; Mollahosseini, A.; Tiraferri, A. A critical review on ultrasonic-assisted fouling control and cleaning of fouled membranes. Ultrasonics 2020, 108, 106228. [Google Scholar] [CrossRef]
  9. Miller, D.L.; Smith, N.B.; Bailey, M.R.; Czarnota, G.J.; Hynynen, K.; Makin, I.R.S. Overview of therapeutic ultrasound applications and safety considerations. J. Ultrasound Med. 2012, 31, 623–634. [Google Scholar] [CrossRef]
  10. Ghahremani, H.; Nasri, Z.; Eikani, M.H. Ultrasound-assisted oxidative desulfurization (UAOD) of Iranian heavy crude oil: Investigation of process variables. J. Pet. Sci. Eng. 2021, 204, 108709. [Google Scholar] [CrossRef]
  11. Karthik, K.; Nikolova, M.P.; Phuruangrat, A.; Pushpa, S.; Revathi, V.; Subbulakshmi, M. Ultrasound-assisted synthesis of V2O5 nanoparticles for photocatalytic and antibacterial studies. Mater. Res. Innov. 2020, 24, 229–234. [Google Scholar] [CrossRef]
  12. Zhang, Z.; Wang, K.; Xu, C.; Zhang, Y.; Wu, W.; Lu, C.; Liu, W.; Rao, Y.; Jiang, C.; Xu, C.; et al. Ultrasound enhancing the mass transfer of droplet microreactor for the synthesis of AgInS2 nanocrystals. Chem. Eng. J. 2022, 435, 134948. [Google Scholar] [CrossRef]
  13. Gogate, P.R.; Sutkar, V.S.; Pandit, A.B. Sonochemical reactors: Important design and scale up considerations with a special emphasis on heterogeneous systems. Chem. Eng. J. 2011, 166, 1066–1082. [Google Scholar] [CrossRef]
  14. Wilhelm, A.-M.; Laugier, F.; Kidak, R.; Ratsimba, B.; Delmas, H. Ultrasound to Enhance a Liquid–Liquid Reaction. J. Chem. Eng. Jpn. 2010, 43, 751–756. [Google Scholar] [CrossRef]
  15. Tay, W.H.; Lau, K.K.; Shariff, A.M. High frequency ultrasonic-assisted chemical absorption of CO2 using monoethanolamine (MEA). Sep. Purif. Technol. 2017, 183, 136–144. [Google Scholar] [CrossRef]
  16. Tay, W.H.; Lau, K.K.; Shariff, A.M. High frequency ultrasonic-assisted CO2 absorption in a high pressure water batch system. Ultrason. Sonochem. 2016, 33, 190–196. [Google Scholar] [CrossRef]
  17. Tay, W.H.; Lau, K.K.; Shariff, A.M. High performance promoter-free CO2 absorption using potassium carbonate solution in an ultrasonic irradiation system. J. CO2 Util. 2017, 21, 383–394. [Google Scholar] [CrossRef]
  18. Yusof, S.M.M.; Lau, K.K.; Shariff, A.M.; Tay, W.H.; Mustafa, N.F.A.; Lock, S.S.M. Novel continuous ultrasonic contactor system for CO2 absorption: Parametric and optimization study. J. Ind. Eng. Chem. 2019, 79, 279–287. [Google Scholar] [CrossRef]
  19. Yusof, S.M.M.; Shariff, A.M.; Tay, W.H.; Lau, K.K.; Mustafa, N.F.A. Mass transfer intensification of CO2 absorption in monoethanolamine using high frequency ultrasonic technology in continuous system. Int. J. Greenh. Gas Control 2020, 102, 103157. [Google Scholar] [CrossRef]
  20. Marjanian, M.M.; Shahhosseini, S.; Ansari, A. Investigation of the ultrasound assisted CO2 absorption using different absorbents. Process Saf. Environ. Prot. 2021, 149, 277–288. [Google Scholar] [CrossRef]
  21. Shokrollahi, F.; Lau, K.K.; Partoon, B.; Lai, L.S. Elucidation of Operating Parameters Influencing the Ultrasonic-Assisted Absorption of Bulk CO 2 Using Unpromoted and Promoted Methyldiethanolamine. Ind. Eng. Chem. Res. 2023, 62, 2843–2865. [Google Scholar] [CrossRef]
  22. Karlsson, H.; Svensson, H. Rate of Absorption for CO2 Absorption Systems Using a Wetted Wall Column. Energy Procedia 2017, 114, 2009–2023. [Google Scholar] [CrossRef]
  23. Pokhrel, N.; Vabbina, P.K.; Pala, N. Sonochemistry: Science and Engineering. Ultrason. Sonochem. 2016, 29, 104–128. [Google Scholar] [CrossRef] [PubMed]
  24. Adewuyi, Y.G. Sonochemistry: Environmental science and engineering applications. Ind. Eng. Chem. Res. 2001, 40, 4681–4715. [Google Scholar] [CrossRef]
  25. Bhangu, S.K.; Ashokkumar, M. Theory of Sonochemistry. In Sonochemistry: From Basic Principles to Innovative Applications; Springer: Cham, Switzerland, 2017; pp. 1–28. [Google Scholar] [CrossRef]
  26. Savun-Hekimoğlu, B. A Review on Sonochemistry and Its Environmental Applications. Acoustics 2020, 2, 766–775. [Google Scholar] [CrossRef]
  27. Wu, T.Y.; Guo, N.; Teh, C.Y.; Hay, J.X.W. Theory and Fundamentals of Ultrasound. In Advances in Ultrasound Technology for Environmental Remediation; Springer: Dordrecht, The Netherlands, 2013; pp. 5–12. [Google Scholar] [CrossRef]
  28. Pham, T.D.; Shrestha, R.A.; Virkutyte, J.; Sillanpää, M. Recent studies in environmental applications of ultrasound. J. Environ. Eng. Sci. 2013, 8, 403–412. [Google Scholar] [CrossRef]
  29. Liao, C.H.; Li, M.H. Kinetics of absorption of carbon dioxide into aqueous solutions of monoethanolamine+N-methyldiethanolamine. Chem. Eng. Sci. 2002, 57, 4569–4582. [Google Scholar] [CrossRef]
  30. Lin, C.Y.; Soriano, A.N.; Li, M.H. Kinetics study of carbon dioxide absorption into aqueous solutions containing N-methyldiethanolamine + diethanolamine. J. Taiwan Inst. Chem. Eng. 2009, 40, 403–412. [Google Scholar] [CrossRef]
  31. Zhang, X.; Zhang, C.F.; Qin, S.J.; Zheng, Z.S. A kinetics study on the absorption of carbon dioxide into a mixed aqueous solution of methyldiethanolamine and piperazine. Ind. Eng. Chem. Res. 2001, 40, 3785–3791. [Google Scholar] [CrossRef]
  32. Shokrollahi, F.; Lau, K.K.; Tay, W.H.; Lai, L.S. Power measurement by calorimetric method using water infrequency range between 1.7 Mhz to 3 Mhz. Int. J. Eng. Technol. 2018, 7, 106–109. [Google Scholar] [CrossRef]
  33. Charbouillot, T.; Brigante, M.; Mailhot, G.; Maddigapu, P.R.; Minero, C.; Vione, D. Performance and selectivity of the terephthalic acid probe for •OH as a function of temperature, pH and composition of atmospherically relevant aqueous media. J. Photochem. Photobiol. A Chem. 2011, 222, 70–76. [Google Scholar] [CrossRef]
  34. Barreto, J.C.; Smith, G.S.; Strobel, N.H.P.; McQuillin, P.A.; Miller, T.A. Terephthalic acid: A dosimeter for the detection of hydroxyl radicals in vitro. Life Sci. 1994, 56, PL89–PL96. [Google Scholar] [CrossRef] [PubMed]
  35. Bjorndalen, N.; Islam, M.R. The effect of microwave and ultrasonic irradiation on crude oil during production with a horizontal well. J. Pet. Sci. Eng. 2004, 43, 139–150. [Google Scholar] [CrossRef]
  36. Kudo, T.; Sekiguchi, K.; Sankoda, K.; Namiki, N.; Nii, S. Effect of ultrasonic frequency on size distributions of nanosized mist generated by ultrasonic atomization. Ultrason. Sonochem. 2017, 37, 16–22. [Google Scholar] [CrossRef]
  37. Tamidi, A.M.; Lau, K.K.; Khalit, S.H. A review of recent development in numerical simulation of ultrasonic-assisted gas-liquid mass transfer process. Comput. Chem. Eng. 2021, 155, 107498. [Google Scholar] [CrossRef]
  38. Miyaji, A.; Kohno, M.; Inoue, Y.; Baba, T. Hydroxyl radical generation by dissociation of water molecules during 1.65 MHz frequency ultrasound irradiation under aerobic conditions. Biochem. Biophys. Res. Commun. 2017, 483, 178–182. [Google Scholar] [CrossRef]
  39. Merouani, S.; Hamdaoui, O.; Rezgui, Y.; Guemini, M. Computational engineering study of hydrogen production via ultrasonic cavitation in water. Int. J. Hydrogen Energy 2016, 41, 832–844. [Google Scholar] [CrossRef]
  40. Luo, Q.; Zhou, Q.; Feng, B.; Li, N.; Liu, S. A Combined Experimental and Computational Study on the Shuttle Mechanism of Piperazine for the Enhanced CO2Absorption in Aqueous Piperazine Blends. Ind. Eng. Chem. Res. 2022, 61, 1301–1312. [Google Scholar] [CrossRef]
  41. Laurence, C.; Berthelot, M. Observations on the strength of hydrogen bonding. Perspect. Drug Discov. Des. 2000, 18, 39–60. [Google Scholar] [CrossRef]
  42. Maleki, A.; Irani, V.; Tavasoli, A.; Vahidi, M. Enhancement of CO2 solubility in a mixture of 40 wt% aqueous N-Methyldiethanolamine solution and diethylenetriamine functionalized graphene oxide. J. Nat. Gas Sci. Eng. 2018, 55, 219–234. [Google Scholar] [CrossRef]
Figure 1. Different effects induced by high-frequency ultrasonic irradiation.
Figure 1. Different effects induced by high-frequency ultrasonic irradiation.
Processes 11 03266 g001
Figure 2. Reaction zones according to hotspot theory.
Figure 2. Reaction zones according to hotspot theory.
Processes 11 03266 g002
Figure 3. Schematic of the ultrasonic-assisted CO2 absorption system.
Figure 3. Schematic of the ultrasonic-assisted CO2 absorption system.
Processes 11 03266 g003
Figure 4. HPLC calibration curve and calibration equation for (a) MDEA, (b) TA.
Figure 4. HPLC calibration curve and calibration equation for (a) MDEA, (b) TA.
Processes 11 03266 g004
Figure 5. HPLC chromatograms of 50 wt% aqueous MDEA solution under different conditions (a) Irradiated, (b) Non-irradiated.
Figure 5. HPLC chromatograms of 50 wt% aqueous MDEA solution under different conditions (a) Irradiated, (b) Non-irradiated.
Processes 11 03266 g005
Figure 6. Concentration variation of aqueous MDEA solution under different testing conditions.
Figure 6. Concentration variation of aqueous MDEA solution under different testing conditions.
Processes 11 03266 g006
Figure 7. HPLC chromatograms of 50 wt% aqueous MDEA solution blended with 10 wt% TA under different conditions (a) Irradiated, (b) Non-irradiated.
Figure 7. HPLC chromatograms of 50 wt% aqueous MDEA solution blended with 10 wt% TA under different conditions (a) Irradiated, (b) Non-irradiated.
Processes 11 03266 g007
Figure 8. Concentration variation of aqueous MDEA solution blended with TA under different testing conditions.
Figure 8. Concentration variation of aqueous MDEA solution blended with TA under different testing conditions.
Processes 11 03266 g008
Figure 9. MDEA molecular structure (Gray, white, red, and blue balls represent C, H, O, and N atoms, respectively).
Figure 9. MDEA molecular structure (Gray, white, red, and blue balls represent C, H, O, and N atoms, respectively).
Processes 11 03266 g009
Figure 10. HPLC chromatograms of CO2 absorption into aqueous MDEA solution under different conditions (a) Irradiated, (b) Non-irradiated.
Figure 10. HPLC chromatograms of CO2 absorption into aqueous MDEA solution under different conditions (a) Irradiated, (b) Non-irradiated.
Processes 11 03266 g010
Figure 11. Concentration variation of aqueous MDEA solution after CO2 absorption under different testing conditions.
Figure 11. Concentration variation of aqueous MDEA solution after CO2 absorption under different testing conditions.
Processes 11 03266 g011
Figure 12. HPLC chromatograms of CO2 absorption into aqueous MDEA solution mixed with TA under different conditions (a) Irradiated, (b) Non-irradiated.
Figure 12. HPLC chromatograms of CO2 absorption into aqueous MDEA solution mixed with TA under different conditions (a) Irradiated, (b) Non-irradiated.
Processes 11 03266 g012
Figure 13. Concentration variation of MDEA and TA under different conditions after CO2 absorption.
Figure 13. Concentration variation of MDEA and TA under different conditions after CO2 absorption.
Processes 11 03266 g013
Figure 14. The reaction mechanism of CO2 absorption into aqueous MDEA solution.
Figure 14. The reaction mechanism of CO2 absorption into aqueous MDEA solution.
Processes 11 03266 g014
Figure 15. Experimental absorption rate of different systems using 0 and 12.36 W ultrasonic power, CO2 initial pressure of 11 bar, temperature of 70 °C, MDEA concentration of 50 wt%, and TA concentration of 10 wt%.
Figure 15. Experimental absorption rate of different systems using 0 and 12.36 W ultrasonic power, CO2 initial pressure of 11 bar, temperature of 70 °C, MDEA concentration of 50 wt%, and TA concentration of 10 wt%.
Processes 11 03266 g015
Table 1. Absorption rate comparison of the various MDEA-based CO2 absorption techniques.
Table 1. Absorption rate comparison of the various MDEA-based CO2 absorption techniques.
AbsorbentMDEAMDEAMDEAMDEAMDEAMDEA
PromoterMEADEADEAPZPZ-
Target GasCO2CO2CO2CO2CO2CO2
TechniqueWWCWWCWWCDCHFUAHFUA
Operating
conditions
CMDEA1.5 kmol·m−31.5 kmol·m−31.5 kmol·m−32.636 kmol·m−350 wt%50 wt%
CPromoter0.1 kmol·m−30.1 kmol·m−30.4 kmol·m−30.364 kmol·m−35 wt%0 wt%
T40 °C40 °C40 °C60 °C70 °C70 °C
P0.239 bar0.335 bar0.4 bar0.8 bar11 bar11 bar
Absorption rate0.12 mol·h−10.15 mol·h−10.25 mol·h−10.12 mol·h−115.23 mol·h−14.20 mol·h−1
Reference[29][30][31][21]
Table 2. The used materials and their respective information.
Table 2. The used materials and their respective information.
MaterialFormulaSupplierPurityApplication
Carbon dioxideCO2Air Products, Kuala Lumpur, Malaysia99.99%Target absorbing gas
Distilled waterH2O-100%Preparation of aqueous solutions
MethyldiethanolamineC5H13NO2Revlogi Materials, Puchong, Malaysia≥99%Main chemical absorbent
Terephthalic acidC8H6O4Sigma Aldrich, Burlington, MA, USA≥99% O H ˙  radical scavenger
Sodium hydroxide NaOHSigma Aldrich, Burlington, MA, USA≥99%HPLC mobile phase
Disodium hydrogen phosphate anhydrousNa2HPO4Merck, Darmstadt, Germany≥99%HPLC mobile phase
Table 3. List of samples subjected to HPLC analysis.
Table 3. List of samples subjected to HPLC analysis.
Group No.Sample Description
A50 wt% aqueous MDEA
B50 wt% aqueous MDEA + 10 wt% TA
C50 wt% aqueous MDEA + CO2
D50 wt% aqueous MDEA + 10 wt% TA + CO2
Table 4. Chromatographic data of aqueous MDEA solution.
Table 4. Chromatographic data of aqueous MDEA solution.
Ultrasonic Power: 12.36 and 0 W, Initial [MDEA]: 50 wt%, Temperature: 70 °C
Identification Method: HPLC-UV
Sample No.ConditionObserved RT of Peak [min]Peak Area × 104 [mAU × s]Identity
A1Irradiated11.0476.14MDEA
A2Non-irradiated11.0175.98MDEA
Table 5. Chromatographic data of aqueous MDEA solution blended with TA.
Table 5. Chromatographic data of aqueous MDEA solution blended with TA.
Ultrasonic Power: 12.36 & 0 W, Initial [MDEA]: 50 wt%, Temperature: 70 °C
Identification Method: HPLC-UV
Sample No.ConditionObserved RT of Peak [min]Peak Area × 104 [mAU × s]Identity
B1Irradiated6.1916.32TA
11.0206.12MDEA
B2Non-irradiated6.1926.81TA
11.0165.98MDEA
Table 6. Chromatographic data of the CO2 absorbed into aqueous MDEA solution.
Table 6. Chromatographic data of the CO2 absorbed into aqueous MDEA solution.
Ultrasonic Power: 12.36 and 0 W, Initial [MDEA]: 50 wt%, Temperature: 70 °C, CO2 Pressure: 10 bar
Identification Method: HPLC-UV
Sample No.ConditionObserved RT of Peak [min]Peak Area × 104 [mAU × s]Identity
C1Irradiated11.0325.64MDEA
6.9820.052Unknown
C2Non-irradiated11.0635.43MDEA
7.0020.055Unknown
Table 7. Chromatographic data of the CO2 absorbed into aqueous MDEA solution mixed with TA.
Table 7. Chromatographic data of the CO2 absorbed into aqueous MDEA solution mixed with TA.
Ultrasonic Power: 12.36W, [MDEA]: 50 wt%, [TA]: 10 wt%, Temperature: 70 °C, Pressure: 10 bar
Identification Method: HPLC-UV
Sample No.ConditionPeak NumberObserved RT of Peak [min]Peak Area × 104 [mAU × s]Identity
D1Irradiated16.1676.43TA
26.9810.06Unknown
311.0185.84MDEA
D2Non-irradiated16.1696.81TA
26.9860.05Unknown
311.0645.55MDEA
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Shokrollahi, F.; Lau, K.K.; Partoon, B. Experimental Evaluation of Chemical Reactions Involved in Ultrasonic-Assisted Absorption of Bulk CO2. Processes 2023, 11, 3266. https://doi.org/10.3390/pr11123266

AMA Style

Shokrollahi F, Lau KK, Partoon B. Experimental Evaluation of Chemical Reactions Involved in Ultrasonic-Assisted Absorption of Bulk CO2. Processes. 2023; 11(12):3266. https://doi.org/10.3390/pr11123266

Chicago/Turabian Style

Shokrollahi, Fatemeh, Kok Keong Lau, and Behzad Partoon. 2023. "Experimental Evaluation of Chemical Reactions Involved in Ultrasonic-Assisted Absorption of Bulk CO2" Processes 11, no. 12: 3266. https://doi.org/10.3390/pr11123266

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop