Review

Analyzing Overlaid Foreign Objects in Chest X-rays—Clinical Significance and Artificial Intelligence Tools

Applied AI Research Lab., Department of Computer Science, The University of South Dakota, Vermillion, SD 57069, USA
*
Author to whom correspondence should be addressed.
Healthcare 2023, 11(3), 308; https://doi.org/10.3390/healthcare11030308
Submission received: 23 December 2022 / Revised: 16 January 2023 / Accepted: 16 January 2023 / Published: 19 January 2023
(This article belongs to the Special Issue Computer-Based Medical Systems)

Abstract

:
The presence of non-biomedical foreign objects (NBFO), such as coins, buttons and jewelry, and biomedical foreign objects (BFO), such as medical tubes and devices in chest X-rays (CXRs), make accurate interpretation difficult, as they do not indicate known biological abnormalities like excess fluids, tuberculosis (TB) or cysts. Such foreign objects need to be detected, localized, categorized as either NBFO or BFO, and removed from CXR or highlighted in CXR for effective abnormality analysis. Very specifically, NBFOs can adversely impact the process, as typical machine learning algorithms would consider these objects to be biological abnormalities producing false-positive cases. It holds true for BFOs in CXRs. This paper examines detailed discussions on numerous clinical reports in addition to computer-aided detection (CADe) with diagnosis (CADx) tools, where both shallow learning and deep learning algorithms are applied. Our discussion reflects the importance of accurately detecting, isolating, classifying, and either removing or highlighting NBFOs and BFOs in CXRs by taking 29 peer-reviewed research reports and articles into account.

1. Introduction

Chest X-rays are the most common, widely available, and affordable diagnostic imaging technique for cardiothoracic and pulmonary disorders [1]. Chest radiography is paramount in identifying abnormalities. CXRs are also used as an early diagnosis tool in the cardiothoracic region identifying lung and heart pathologies such as: atelectasis, consolidation, pneumothorax, pleural and pericardial effusion, cardiac hypertrophy, tuberculosis (TB), HIV and hyperinflation [1].
The detection of pulmonary abnormalities concerning tuberculosis (TB) with the presence of foreign objects could influence decision-making procedures [2]. An extensive number of individuals worldwide suffer from serious lung diseases, such as tuberculosis, pneumonia, lung cancer, and pulmonary edema [3] according to a World Health Organization (WHO) report. A total of 1.5 million people died from TB in 2020 (including 214,000 people with HIV). Worldwide, TB is the 13th leading cause of death and the second leading infectious killer after COVID-19 (above HIV/AIDS) [4]. A total of 1.80 million people has died from lung cancer [5] and pneumonia accounts for 14% of all deaths of children under 5 years old, killing 740,180 children in 2019 [6]. The development of CADs for automatic CXR screening has been prompted by the introduction of new, very effective hardware and software methodologies [7,8,9] (TB cases). More than 6.5 million people have died due to COVID-19 [10] which could have been less if we had considered the CAD system during the pandemic [11,12,13]. However, without proper instructions and training CAD can give us false-positive results. For example, foreign elements, such as buttons, coins, medical tubes, and medical devices within the CXR images hinder the performance of the automatic screening system, and we can divide these foreign objects into two groups (BFO and NBFO). Any medical devices, such as pacemakers, buttons, and pinnodes which can be found on a medical gown that patients are wearing, and medical tubes, jewelry, and so forth are considered as a BFO in CXR images. On the other hand, coins or rings which are mistakenly swallowed by patients, candy wrappers, broken toys, and so forth are considered NBFO in CXR images. BFO is a nonharmful foreign object and it is not considered a lung abnormality in CXR images [14,15]. For example, people who are in an intensive care unit (ICU) need BFO, or people who have a pacemaker in their heart cannot get rid of it in the CAD process. Meanwhile, if we failed to detect, localize, and identify NBFO early, it could be a serious threat to our health. Even clinicians could sometimes fail to detect it properly. For example, a tiny circle is considered an abnormality for TB. However, it could be buttons, rings, or coins. Therefore, in the screening process, precise detection of foreign objects is an important issue for screening chest diseases in CAD systems. Figure 1 shows the BFO (medical device, tube, buttons, pinnode) and NBFO (chain, ring) in CXR images with annotations. Figure 2 shows a closer view of the NBFO (chain and ring) and BFO (medical devices, medical tube, buttons, and pinnodes).
This paper focuses on the impact of NBFOs in CXRs by reviewing clinical studies and how much work has been done to detect and classify NBFOs and BFOs using artificial intelligence (AI)-guided tools. In Section 2, we describe our search criteria. In Section 3, we review clinical significance by considering NBFOs and their possible impacts. We then discuss the use of AI-guided tools to detect and localize foreign objects in CXRs. Section 4 includes both shallow learning and deep learning algorithms. While reviewing the performance of machine learning, we review data sets and their respective sources in Section 5. Section 6 concludes our study.

2. Inclusion/Exclusion Criteria

Our review process includes search keywords, search space, inclusion criteria, and exclusion criteria.
  • Search keywords: (chest X-ray OR chest radiograph) AND (foreign object detection) OR object detection.
  • Search spaces: PubMed and Web of Science.
As we primarily consider experimental papers with clinical significance that are primarily aimed for pulmonary abnormality screening, we reviewed 29 papers in total. We did not consider preprint papers (e.g., ArXiv, medRxiv, and TechRxiv) as they are not peer-reviewed.

3. Clinical Significance

In this section, we review the impact of BFOs and NBFOs from a clinical perspective, and based on literature from the 1980s onward, we consider the following types of NBFOs: magnets, button batteries, coins, disk magnets, scarf pins, metallic candy wrappers, as well as BFOs which turned out to be chest tubes, automatic implantable cardiovascular defibrillators, cardiopulmonary devices, pacemakers, catheters, intra-aortic counter pulsation balloon pumps, ventricular assist devices, endotracheal and tracheostomy tubes, nasogastric and nasoenteric tubes, and medically implanted wires, to name a few. The following discussion highlights these NBFOs and BFOs as they appear in CXRs.
Batteries and magnets are common in children’s toys and the ingestion of these items is an increasingly common theme with children. The harm in swallowing these items is often difficult to express for young children, including autistic, developmentally delayed, non-verbal, or non-disclosing children. In the Ref. [16] the authors showed a case study where challenges occurred in identifying and locating magnets and batteries in CXRs ingested by children. They reported that mild symptoms and signs resulted in a delayed diagnosis leading to serious consequences. Initially, these symptoms were mistakenly diagnosed as gastric issues, which prompted the CXRs. In the Ref. [17] Pugmire et al. presented a 15-year single-centered review from 2000 to 2015, based on clinical reports and images from Cincinnati Children’s Hospital Medical Center, where 276 cases of battery ingestion and insertions were confirmed. Fuentes et al. provided a case report in the Ref. [18] in which button batteries made up a small percentage of all foreign bodies eaten by children, and their position in the esophagus is even less common, making them more likely to cause serious injury. They presented three cases of children (2–7 years old) in which CXR imaging revealed circular NBFOs in the middle esophagus with unilateral esophageal burns (EB). In two of the three patients, the EBs progressed to esophageal stenosis. The researchers discovered 29 more cases in their investigation, with injuries including EB, esophageal perforation (EP), and tracheoesophageal fistula (TEF). They also stated that dysphagia or odynophagia were the primary symptoms in most patients (56%); however, non-specific symptoms, such as irritability, vomiting, and cough were also prevalent.
The growing number of small electronic devices with an electric supply by lithium button batteries (LBBs) has increased the number of cases of LBB ingestions, causing severe medical complications [19]. In the Ref. [20] Meyer et al. presented a study where the main aim was to analyze relevant diagnostic aspects of lithium button battery (LBB) X-ray imaging, and retrospective analysis of the imaging of radiopaque foreign bodies. For this study, they listed commercially available LBBs and alternate NBFOs, such as European coins (EC) and disk magnets (DM) according to their sizes and compositions. Thompson et al. compared digital and analog radiographs of the chest for use in detecting and evaluating a variety of cardiopulmonary devices (BFOs) in 40 patients which included 23 endotracheal tubes, 21 Swan–Ganz catheters, 14 central venous pressure catheters, 11 prosthetic valves, 10 chest tubes, six pacemaker wires, and five intra-aortic balloon pumps in the Ref. [21]. The validation of 40 digital and analog film pairs was compared by five radiologists, who assigned confidence levels for various judgments about each device. The results showed that there were no statistically significant differences in the identification of the devices except for prosthetic valves (all valves were detected on digital radiographs, compared with 62% on analog radiographs). The devices were detected on 96% of the digital radiographs and 90% of the analog radiographs.
The radiographic evaluation of the support and monitoring devices used in patients in the intensive care unit (ICU) is critically important because the potentially serious complications arising from their introduction and use are often not clinically apparent. For example, central venous catheters, pulmonary artery catheters, left atrial catheters, transvenous pacemakers, automatic implantable cardioverter defibrillators, intra-aortic counter pulsation balloon pumps, and ventricular assist devices are frequently used in critically ill patients. Godoy et al. [22,23] discussed and illustrated normal and aberrant positioning of support and monitoring devices frequently used in critically ill patients, including endotracheal and tracheostomy tubes, chest tubes, and nasogastric and nasoenteric tubes, as well as their inherent complications in radiography. Jennings et al. [24] compared computed and traditional radiography for the identification and visualization of cardiovascular devices in intensive care unit patients. Using a 2K × 2K, 12-bit storage phosphor plate technique that is readily available, they produced their calculated pictures. Three independent observers evaluated the validity of these 50 patient image sets. The observers noted a large variation in the sorts of images discovered for the detection of prosthetic valves and mediastinal drainage tubes. Greater assurance in identifying courses and line tips was seen in the computed pictures. They claimed that knowledge of typical and aberrant radiography findings is crucial for spotting these devices.
In the Ref. [25] Grier et al. reviewed the chest radiographs of 600 consecutive patients to review the necessity of chest radiography after undergoing insertion of a permanent cardiac pacemaker. The incidence and nature of CXR abnormalities were reviewed. They reported that abnormalities were detected on the chest radiographs of 131 patients (21.8%). Unsatisfactory electrode tip positions and other features related to the electrode wire were most common (14.4%). Complications related to the lungs and pleura were present at 5.5%, and those related to the generator and pouch were least frequent (1.9%). Complications occurred more frequently following the installation of a replacement system (48.3%) compared to new systems (17.2%). Important complications not initially detected included pneumothorax (8/15) and poor electrode loops (26/27). Chest radiographs following permanent cardiac pacing frequently demonstrate significant abnormalities whose detection is improved by awareness of their incidence and nature.
Murthy et al., in the Ref. [26] provided a case report of six patients who were brought with a history of aspirating a sharp foreign body (scarf pin). The ages of the patients, all of whom were female, ranged from 5 to 16. Between three hours and a day following the unintentional consumption, patients were admitted to hospitals. None of the patients had any localized respiratory obstruction symptoms or indications. They provided examples of the risks associated with mouth-holding by girls. It was demonstrated how to handle these pointed, potentially piercing foreign bodies. On the other hand, the majority of airway NBFOs occurs in children between the ages of 6 months and 6 years. Candy is something that children are particularly fond of, resulting in a high chance that kids may consume candy wrappers as well as candy. In the Ref. [27] Orgill et al. presented a case where the main goal was determining whether conventional and dual-energy radiographic techniques would exclude the presence of aspirated metallic foil wrappers. Single-layer and multi-layer metallic candy wrappers were radiographically studied with conventional and dual-energy radiographic techniques in three tissue models. They reported that no single-layer metallic samples were detectable with conventional or dual-energy radiography. The multilayer samples were non-detectable at less than 8 layers (pulmonary tissue model) or 16 layers (mediastinal model) by either conventional or dual-energy radiography. Findings indicate that conventional and dual-energy chest radiographic techniques do not reliably exclude the presence of aspirated metallic foil wrappers.
Coins currently represent the most retained esophageal foreign body among children in the United States [28,29,30]. Suspicion for coin ingestion is typically brought on by witnessed ingestion or symptoms such as gagging, choking, vomiting, and dysphagia [28]. In the Ref. [31] the focus of Huyett et al. was to determine the accuracy of CXRs in children using ingested radiopaque NBFOs of known size. A database of foreign body ingestion at a tertiary care children’s hospital was queried from 2013 to 2016 for children who had ingested US coins, had a pre-operative chest X-ray, and documentation of coin type at the time of endoscopic removal. Four blind research tests measured the coin diameter on chest X-rays using iSite PACS software, and based on the measurement, predicted the coin type. Researchers concluded that the measurement of esophageal coins on chest X-ray was relatively inaccurate and overestimates the size in most cases, and clinicians should exercise caution when performing fine measurements on chest X-rays, especially in children younger than 4 years old. Raney et al., in the Ref. [32] presented a case study where a child had ingested an esophageal coin, but radiographic findings supported a coin located in the trachea. This case study illustrates the importance of performing radiographic studies that include both anteroposterior and lateral neck/chest views in patients who aspirate or swallow coins. The purpose of this report is to show that there are exceptions to the guidelines used to interpret roentgenograms for the determination of esophageal or tracheal coin location. Tander et al. evaluated patients with coins retained in the esophagus and the impact of the size of the coins on lodgment location in the Ref. [33]. They investigated 62 children with a history of coin ingestion and a chest X-ray, showing a retained coin in the esophagus. They reported that there were 27 male and 35 female patients with coin lodgment (median age, 4 years; range, 1–13). Forty-five patients (73%) ingested a coin with a diameter between 23.45 and 26.00 mm. In the remaining 17 patients (27%), ingested coins had a diameter between 17.00 and 20.90 mm or between 26.85 and 28.00 mm. Fifty coins were localized in the upper esophagus, eight coins were found in the middle esophagus, and four patients had a coin in the distal esophagus. There was a positive correlation between the diameter of the coin and the age of the patient (r = 0.415 and P¡ 0.001). Even though esophageal NBFOs in children remains an important and complex medical subject, these accidental ingestions can be dangerous for adults as well. Teenagers often keep pen tops or pins in their mouths during their routine daily activities. In the Ref. [34] Rybojad et al. worked with a study of 192 cases of suspected esophageal NBFOs between 1998 and 2010. One radiopaque showed a wedding ring in the esophageal area. Rybojad et al. mentioned that sometimes NBFO ingestions can be difficult to diagnose. In suspected cases, the doctors X-rayed both a lateral chest and neck profile. The authors discussed clinical symptoms and radiological findings of variable esophageal NBFOs as well as therapeutic procedures in pediatric patients. Data were statistically analyzed by a chi-square test. Reporting’s demonstrated that a NBFO was removed from the digestive tract of 163 children aged 6 months to 15 years (mean age 4.9). Most objects were located within the cricopharyngeal sphincter. Dysphagia occurred in 43%, followed by vomiting (29%) and drooling (28%). The most common ingested objects were coins. Ordinal chest X-rays demonstrated aberrations in 132 cases, and in uncertain situations, an esophagram test was additionally ordered. For the group of 37 patients whose radiograms were normal, esophagoscopy revealed fifteen more NBFOs, which were eventually successfully removed. In the Ref. [35] Schlesinger and Crowe evaluated the clinical presentation and radiographic appearance in eight cases of esophageal coins in children with an atypical sagittal orientation on chest radiographs. They reviewed patient age, sex, type of coin, location of the coin within the esophagus, method of coin removal, presence of underlying esophageal anomalies, treatment, and complications related to the coin ingestion or removal among the clinical records and chest radiographs of eight children. They reported that the age of the eight children ranged from 3.8 to 17.7 years (mean, 7.8 years), the coins were lodged at the level of the aortic arch in seven of the eight patients and the level of the distal third of the esophagus in one patient. One of the eight cases showed the coin was originally in the sagittal plane but spontaneously reoriented into the coronal plane. They also mentioned that the coins with a sagittal orientation on chest radiographs in the trachea were usually not correct. A coin seen with a sagittal orientation on a chest radiograph will more likely be in the esophagus.
In the Ref. [36] Ullal et al. presented the case study of a new investigative technique of virtual bronchoscopy, which is useful in locating non-radiopaque NBFOs missed using ordinal radiography. The aim was to study the clinical profile of patients with suspected NBFO aspiration and to evaluate the changing trends in the diagnosis for quicker management of NBFO aspiration by the way of virtual bronchoscopy. For validation, Ullal et al. reviewed the medical records of patients with NBFO aspiration from August 2006 to September 2016. They reported that in 150 patients with NBFO aspiration, detected by virtual bronchoscopy, 148 patients were diagnosed to have NBFO by rigid bronchoscopy. This amounts to a positive predictive value of 97.3% which was like the positive predictive value of rigid bronchoscopy at 99%. Virtual bronchoscopy is the only imaging modality that returned 99.9% reassurance about the presence or absence of a NBFO, because of both its high sensitivity and specificity, proving to be a lifesaving tool. On the other hand, Morrier et al. [37] evaluated the efficacy of a seed-migration detector and compared its performance to fluoroscopy and postoperative chest radiographs. Their propositions use a gamma scintillation survey meter which was converted to a seed-migration detector by adding a shield on the probe detection window. To validate, the detector was used to perform a chest evaluation on 737 patients at their first postoperative visit. When the detector showed positive activity, seed migration was confirmed by taking a chest radiograph and by looking at the region with fluoroscopy. They reported that 103 patients (14.0%) presented at least one embolized seed. This accounts for 123 of the 39,887 seeds. A total of 87, 12, and 4 patients had 1, 2, and 3 seed embolizations, respectively. Compared with the seed-migration detector, detection based on fluoroscopy had led to 13 false-negative detections (of 103, or 12.6%), and the radiograph had resulted in 31 or 30.1. In the Ref. [38] Kero et al. presented a report during the years 1969–1981 where 57 children with inhaled NBFOs in the tracheobronchial tree were treated at Turku University Hospital. They reported that 91% had a history of NBFO inhalation and 25% had a radiopaque NBFO which was seen in the CXR. A total of 9% of 57 patients had a NBFO discovered unexpectedly through bronchoscopy. These NBFOs were removed by bronchoscopy from all the patients but one, who required a segmentectomy due to a fragment of a spike in the lung parenchyma. Overall, we found that it is frequently challenging to identify NBFOs in clinical settings since patients rarely exhibit any specific symptoms, even though the longer they remain in the chest region, the greater the risk to their health. Additionally, employing CXR to detect NBFOs early in clinical fields is not an effective method, which motivates us to examine CAD performance, as detailed in the following section of our research. In Table 1, all these cases and subjects are described from clinical observation.

4. AI-Guided Tools for NBFO and BFO

Typical AI-guided tools work as demonstrated in Figure 3. In Figure 3, annotated NBFOs and BFOs are used to train AI-guided tools that employ image processing, machine learning, computer vision, and pattern recognition algorithms to detect/classify foreign objects: NBFO and BFO.
Automatically detecting foreign objects in CXRs is not trivial [39] and it does not have rich state-of-the-art literature. Often, shallow learning algorithms are used, and feature engineering covers most of it, where basic image processing and pattern recognition techniques are common. A technique to identify NBFOs in chest X-rays, such as buttons on the patient’s robe, was developed by Zohora et al. [2]. The four main techniques used in these claims—intensity normalization, low-contrast picture identification and enhancement, segmentation of lung areas, and button object extraction are based on the Hough transform and the Viola–Jones algorithm. Using a ground truth dataset of 505 button objects, they examined and contrasted both methods for validating these approaches. Using a new method, Zohora et al. [40] mentioned the detection of circular NBFOs and BFOs (such as buttons and medical devices) in lung areas. They first created an edge map using a variety of edge detection methods, then performed morphological procedures to choose possible candidates. They applied the circular Hough transform (CHT), and with lung segmentation, they reported precision, recall, and F1 scores of 96%, 90%, and 92%, respectively. Their results are comparable with state-of-the-art works. An automated approach was created by Hogeweg et al. [41] to identify and eliminate NBFOs and BFOs from chest radiographs, such as buttons, brassier clips, jewelry, pacemakers, and wires. These methods produced a probability estimate for each pixel belonging to a projected NBFO and BFO by using supervised pixel classification using a kNN classifier. By grouping and post-processing pixels with a probability greater than a specific benchmark threshold, segmentation was carried out. In paintings, texture took the place of actual objects. They assessed trials on 257 chest radiographs and the reported accuracy of the detection at a pixel level value of 0.949 to validate this method. At the object level, free response operator characteristic analysis revealed that 95.6% of objects were recognized with an average of 0.25 false-positive detections per image.
Schultheiss et al. [42] developed a design to improve the early detection of lung cancer in computed tomography and CXR. Based on segmented pulmonary nodules, their model trained a convolutional neural network (CNN) based on a single-stage detector (RatinaNet) with 257 annotated radiographs and 154 additional radiographs from a public dataset. They conducted a reader study with 75 cases to validate the design and found that for nodule location detection, the architecture had a performance of 43 true-positives, 26 false-positives, and 22 false-negatives. They also compared the performance of the convolutional neural network with the performance of two radiologists. In contrast, the dual readers performed with 42 true-positives and 2 false-positives, 28 true-positives and 0 false-positives, and 23 false-negatives. They found a ROC, AUC value of 0.87 for the reader study testing the trained RetinaNet architecture to be only marginally susceptible to detect NBFOs and BFOs in terms of misclassifications: out of 59 additional radiographs containing NBFOs and BFOs, two radiographs had false positives that were mistakenly identified as foreign bodies.
Deshpande et al. [43] proposed a design to classify NBFOs (e.g., tubes and wires, pacemakers, implants, small external objects, jewelry, and pushbuttons) in CXRs. They used a deep learning framework with the subset of the MIMIC CXR dataset and annotated 6061 images with the primary purpose of classifying NBFOs. Their networks were pre-trained using ImageNet on the NIH database ChestX-ray14. Using five-fold cross-validation on 4704 images plus an additional test set containing 1357 images, they reported classification AUCs of 0.984 (for binary classification) and 0.96 (for multilabel classification). Note that their objective was to classify foreign objects, not detection and/or localization of foreign objects. As a result, it was not included in Table 2.
Santosh et al. [44] created a method that used a faster region-based convolutional neural network to detect circle-like NBFOs (such as coins and buttons) of various sizes during an automated CXR screening process (R-CNN). On a set of 400 publicly accessible CXR images hosted by LHNCBC, the U.S. National Library of Medicine (NLM), and the National Institute of Health (NIH), the authors validated the use of the proposed deep neural network (DNN) and achieved 97% precision, 90% recall, and a 93% F1-score. All these reported works were mostly limited to circle-like foreign object detection. Using this same dataset, Santosh et al. [45] published their recent work based on a YOLOv4-a DNN-based object detection technique, and they were able to detect all kinds of foreign objects (BFO and NBFO) in their research. They achieved the following performance scores: accuracy of 91.00%, precision of 85.00%, recall of 93.00%, and f1-score of 89.00%. Unlike state-of-the-art works, where they are limited to a specific type of foreign object (e.g., circle-like objects), this is the first time they reported experimental results on all possible types of foreign objects. In Table 2, the methods and performance of detecting BFOs and NBFOs are described.

5. Data Description

In this section, we summarize datasets used in Section 4. Table 3 includes the dataset name size and the author’s name, which are mentioned in Section 4. The National Library of Medicine (NLM) dataset, which had been preserving a sizable dataset of chest radiographs as well as related radiological reports, was used by Xue et al. [39]. This dataset, compiled by the medical school at the University of Indiana, includes around 4000 frontal and lateral chest X-ray DICOM image pairings and 4000 textual reports that correlate to the images [46]. It was incorporated into Open-i, a multi-modal system for retrieving biological literature created by NLM [47]. The creation and evaluation of computer-aided diagnosis (CAD) algorithms for lung disorders can benefit from this dataset.
Zohora et al. [2,40] used a subset of the dataset maintained by the National Library of Medicine (NLM) composed of 50 DICOM and 400 DICOM CXRs images. There was a total of 32 buttons on the chest of this subgroup of the data set. Since they are not present in this data set, they marked the related ground truths. Additionally, Santosh et al. [44,45] used the same dataset of 400 CXR images in their experimental work.
For evaluation of the detection and removal of NBFO, Hogeweg, et al. [41] used a large chest radiograph database of 257 chest radiographs from a tuberculosis screening program for high-risk groups in London [48]. Each image was captured digitally using a single device (DigitalDiagnost Trixel, Philips Healthcare, the Netherlands). According to the size of the source image, all photos in this work were scaled to a width of 1024 pixels, giving them resolutions ranging from 0.22 to 0.38 mm per pixel. They discovered that this resolution is adequate for the detection of tuberculosis-related anomalies in chest radiographs, even though the original resolution is about a factor of 2 higher (0.144 mm pixel size). For the identification and segmentation of NBFOs, this resolution also proved sufficient. Full-resolution photographs could also use inpainting if desired. NBFOs can be found in this database’s photos in about 20% of the cases. A subset of this database was used to evaluate the automatic detection of foreign objects and their effect on the automatic detection of textural abnormalities.
A dataset of 391 CXRs was collected from Schultheiss et al. [42] and the institution’s picture archiving and communication system (PACS). Therefore, case-level ground truth labels (unsuspicious or nodulous) were assigned based on the diagnosis of two radiologists: the first radiologist made the diagnosis according to a clinical routine, and a second radiologist (who had 3 years of experience in chest imaging) verified and segmented the nodules, retrospectively, using our in-house built web-based platform. Another radiologist checked the segmented nodules for the reader study test set (12 years of experience). Based on the segmentation boundaries, bounding boxes were extracted from the segmentations. A total of 257 radiographs with nodules were utilized for training purposes. The Japanese Society of Radiological Technology (JSRT) dataset 31, from which 154 additional radiographs with labeled nodules were obtained, was used to complement the training data. Consequently, 411 radiographs were used in total for training. To train a lung segmentation network, lung segmentations for each of the 247 JSRT files were also taken from the segmentation in chest radiography (SCR) database 32. Please take note that 93 more non-nodulous photos from the JSRT database were included in the data for lung segmentation. For the lung segmentation train, validation and test set sizes were set to 157, 40, and 50.

6. Conclusions

In this paper, we analyzed overlaid foreign objects in chest X-ray (CXR) images by considering two factors: clinical significance and AI-guided tools. Both non-biomedical foreign objects (NBFOs) and biomedical foreign objects (BFOs) were considered in our study since we were required to have effective reading and accurate interpretation of CXRs. While reviewing, we observed that NBFOs range from accidentally ingested batteries, coins, hair pins, jewelry, candy wrappers, hardware, or toys, and BFOs include biomedical devices like pacemakers, medical device wiring, medically installed prostheses, and medical tubing. In addition to clinical significance, we examined the detailed discussions on numerous clinical reports in addition to computer-aided detection (CADe) with diagnosis (CADx) tools. In CADe and CADx, both shallow learning and deep learning algorithms were considered. When it comes to automation, AI-guided tools (with the possibility of having explainability and/or interpretability) are a must, but they require larger datasets.

Author Contributions

Both authors contributed equally to the paper. This paper is the thorough extension of S. Roy’s thesis report (USD Computer Science, 2022). All authors have read and agreed to the published version of the manuscript.

Funding

This research was supported by the Applied AI research lab, University of South Dakota.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Raoof, S.; Feigin, D.; Sung, A.; Raoof, S.; Irugulpati, L.; Rosenow III, E.C. Interpretation of plain chest roentgenogram. Chest 2012, 141, 545–558. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Zohora, F.T.; Santosh, K. Circular foreign object detection in chest x-ray images. In Proceedings of the International Conference on Recent Trends in Image Processing and Pattern Recognition, Bidar, India, 16–17 December 2016; 2016; pp. 391–401. [Google Scholar]
  3. El-Baz, A.; Beache, G.M.; Gimel’farb, G.; Suzuki, K.; Okada, K.; Elnakib, A.; Soliman, A.; Abdollahi, B. Computer-aided diagnosis systems for lung cancer: Challenges and methodologies. Int. J. Biomed. Imaging 2013, 2013, 942353. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Tuberculosis (TB). Available online: https://www.who.int/news-room/fact-sheets/detail/tuberculosis (accessed on 25 July 2022).
  5. Cancer. Available online: https://www.who.int/health-topics/cancer#tab=tab_1 (accessed on 25 July 2022).
  6. Antani, S. Automatic x-ray screening for tuberculosis. SPIE Newsroom. 2015. Available online: http://www.spie.org/x115742.xml (accessed on 3 January 2016).
  7. Santosh, K.; Vajda, S.; Antani, S.; Thoma, G.R. Edge map analysis in chest X-rays for automatic pulmonary abnormality screening. Int. J. Comput. Assist. Radiol. Surg. 2016, 11, 1637–1646. [Google Scholar] [CrossRef] [PubMed]
  8. Baltruschat, I.M.; Nickisch, H.; Grass, M.; Knopp, T.; Saalbach, A. Comparison of deep learning approaches for multi-label chest X-ray classification. Sci. Rep. 2019, 9, 6381. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  9. Vajda, S.; Karargyris, A.; Jaeger, S.; Santosh, K.; Candemir, S.; Xue, Z.; Antani, S.; Thoma, G. Feature selection for automatic tuberculosis screening in frontal chest radiographs. J. Med. Syst. 2018, 42, 1–11. [Google Scholar] [CrossRef]
  10. WHO Coronavirus (COVID-19) Dashboard. Available online: https://covid19.who.int/#:~:text=Globally%2C%20as%20of%206%3A45pm,vaccine%20doses%20have%20been%20administered (accessed on 25 July 2022).
  11. Santosh, K.; Ghosh, S.; GhoshRoy, D. Deep learning for COVID-19 screening using chest x-rays in 2020: A systematic review. Int. J. Pattern Recognit. Artif. Intell. 2022, 36, 2252010. [Google Scholar] [CrossRef]
  12. Santosh, K.; Ghosh, S. COVID-19 imaging tools: How big data is big? J. Med. Syst. 2021, 45, 1–8. [Google Scholar] [CrossRef]
  13. Santosh, K. AI-driven tools for coronavirus outbreak: Need of active learning and cross-population train/test models on multitudinal/multimodal data. J. Med. Syst. 2020, 44, 1–5. [Google Scholar] [CrossRef] [Green Version]
  14. Mahbub, M.K.; Biswas, M.; Gaur, L.; Alenezi, F.; Santosh, K. Deep features to detect pulmonary abnormalities in chest X-rays due to infectious diseaseX: COVID-19, pneumonia, and tuberculosis. Inf. Sci. 2022, 592, 389–401. [Google Scholar] [CrossRef]
  15. Santosh, K.; Antani, S. Automated chest X-ray screening: Can lung region symmetry help detect pulmonary abnormalities? IEEE Trans. Med. Imaging 2017, 37, 1168–1177. [Google Scholar] [CrossRef]
  16. Brown, J.C.; Murray, K.F.; Javid, P.J. Hidden attraction: A menacing meal of magnets and batteries. J. Emerg. Med. 2012, 43, 266–269. [Google Scholar] [CrossRef] [PubMed]
  17. Pugmire, B.S.; Lin, T.K.; Pentiuk, S.; de Alarcon, A.; Hart, C.K.; Trout, A.T. Imaging button battery ingestions and insertions in children: A 15-year single-center review. Pediatr. Radiol. 2017, 47, 178–185. [Google Scholar] [CrossRef] [PubMed]
  18. Fuentes, S.; Cano, I.; Benavent, M.I.; Gómez, A. Severe esophageal injuries caused by accidental button battery ingestion in children. J. Emergencies Trauma Shock. 2014, 7, 316–321. [Google Scholar] [CrossRef] [PubMed]
  19. Gummin, D.D.; Mowry, J.B.; Spyker, D.A.; Brooks, D.E.; Fraser, M.O.; Banner, W. 2016 annual report of the american association of poison control centers’ national poison data system (NPDS): 34th annual report. Clin. Toxicol. 2017, 55, 1072–1254. [Google Scholar] [CrossRef] [PubMed]
  20. Meyer, T.J.; Grunz, J.-P.; Taeger, J.; Rak, K.; Hagen, R.; Hackenberg, S.; Voelker, J.; Scherzad, A. Systematic analysis of button batteries’, euro coins’, and disk magnets’ radiographic characteristics and the implications for the differential diagnosis of round radiopaque foreign bodies in the esophagus. Int. J. Pediatr. Otorhinolaryngol. 2020, 132, 109917. [Google Scholar] [CrossRef] [PubMed]
  21. Thompson, M.J.; Kubicka, R.A.; Smith, C. Evaluation of cardiopulmonary devices on chest radiographs: Digital vs analog radiographs. Am. J. Roentgenol. 1989, 153, 1165–1168. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  22. Godoy, M.C.; Leitman, B.S.; De Groot, P.M.; Vlahos, I.; Naidich, D.P. Chest radiography in the ICU: Part 2, Evaluation of cardiovascular lines and other devices. Am. J. Roentgenol. 2012, 198, 572–581. [Google Scholar] [CrossRef] [PubMed]
  23. Godoy, M.C.; Leitman, B.S.; De Groot, P.M.; Vlahos, I.; Naidich, D.P. Chest radiography in the ICU: Part 1, Evaluation of airway, enteric, and pleural tubes. Am. J. Roentgenol. 2012, 198, 563–571. [Google Scholar] [CrossRef]
  24. Jennings, P.; Padley, S.P.; Hansell, D.M. Portable chest radiography in intensive care: A comparison of computed and conventional radiography. Br. J. Radiol. 1992, 65, 852–856. [Google Scholar] [CrossRef]
  25. Grier, D.; Cook, P.; Hartnell, G. Chest radiographs after permanent pacing. Are they really necessary? Clin. Radiol. 1990, 42, 244–249. [Google Scholar] [CrossRef]
  26. Murthy, P.; Ingle, V.; George, E.; Ramakrishna, S.; Shah, F.A. Sharp foreign bodies in the tracheobronchial tree. Am. J. Otolaryngol. 2001, 22, 154–156. [Google Scholar] [CrossRef] [PubMed]
  27. Orgill, R.D.; Pasic, T.R.; Peppler, W.W.; Hoffman, M.D. Radiographic evaluation of aspirated metallic foil foreign bodies. Ann. Otol. Rhinol. Laryngol. 2005, 114, 419–424. [Google Scholar] [CrossRef] [PubMed]
  28. Sink, J.R.; Kitsko, D.J.; Mehta, D.K.; Georg, M.W.; Simons, J.P. Diagnosis of pediatric foreign body ingestion: Clinical presentation, physical examination, and radiologic findings. Ann. Otol. Rhinol. Laryngol. 2016, 125, 342–350. [Google Scholar] [CrossRef]
  29. Fisher, J.; Mittal, R.; Hill, S.; Wulkan, M.L.; Clifton, M.S. Yield of chest radiography after removal of esophageal foreign bodies. Pediatrics 2013, 131, e1497–e1501. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  30. Denney, W.; Ahmad, N.; Dillard, B.; Nowicki, M.J. Children will eat the strangest things: A 10-year retrospective analysis of foreign body and caustic ingestions from a single academic center. Pediatr. Emerg. Care 2012, 28, 731–734. [Google Scholar] [CrossRef] [PubMed]
  31. Huyett, P.; Shaffer, A.; Flom, L.; Simons, J.P.; Jabbour, N. Accuracy of chest X-Ray measurements of pediatric esophageal coins. Int. J. Pediatr. Otorhinolaryngol. 2018, 113, 1–3. [Google Scholar] [CrossRef] [PubMed]
  32. Raney, L.H.; Losek, J.D. Child with esophageal coin and atypical radiograph. J. Emerg. Med. 2008, 34, 63–66. [Google Scholar] [CrossRef] [PubMed]
  33. Tander, B.; Yazici, M.; Rizalar, R.; Ariturk, E.; Ayyildiz, S.H.; Bernay, F. Coin ingestion in children: Which size is more risky? J. Laparoendosc. Adv. Surg. Tech. 2009, 19, 241–243. [Google Scholar] [CrossRef] [PubMed]
  34. Rybojad, B.; Niedzielska, G.; Niedzielski, A.; Rudnicka-Drozak, E.; Rybojad, P. Esophageal foreign bodies in pediatric patients: A thirteen-year retrospective study. Sci. World J. 2012, 2012, 102642. [Google Scholar] [CrossRef] [Green Version]
  35. Schlesinger, A.E.; Crowe, J.E. Sagittal orientation of ingested coins in the esophagus in children. Am. J. Roentgenol. 2011, 196, 670–672. [Google Scholar] [CrossRef]
  36. Ullal, A.; Mundra, R.; Gupta, Y.; Mishra, S. Virtual bronchoscopy: Highly sensitive time and life saving investigation in the diagnosis of foreign body aspiration—Our experience. Indian J. Otolaryngol. Head Neck Surg. 2019, 71, 378–383. [Google Scholar] [CrossRef] [PubMed]
  37. Morrier, J.; Chrétien, M.; Martin, A.-G.; Vigneault, É.; Beaulieu, L. A more efficient, radiation-free alternative to systematic chest x-ray for the detection of embolized seeds to the lung. Int. J. Radiat. Oncol. Biol. Phys. 2010, 78, 1052–1056. [Google Scholar] [CrossRef] [PubMed]
  38. Kero, P.; Puhakka, H.; Erkinjuntti, M.; Iisalo, E.; Vilkki, P. Foreign body in the airways of children. Int. J. Pediatr. Otorhinolaryngol. 1984, 6, 51–59. [Google Scholar] [CrossRef] [PubMed]
  39. Xue, Z.; Candemir, S.; Antani, S.; Long, L.R.; Jaeger, S.; Demner-Fushman, D.; Thoma, G.R. Foreign object detection in chest X-rays. In Proceedings of the 2015 IEEE international conference on bioinformatics and biomedicine (BIBM), Washington, DC, USA, 9–12 November 2015; pp. 956–961. [Google Scholar]
  40. Zohora, F.T.; Santosh, K. Foreign circular element detection in chest x-rays for effective automated pulmonary abnormality screening. Int. J. Comput. Vis. Image Process. 2017, 7, 36–49. [Google Scholar] [CrossRef]
  41. Hogeweg, L.; Sánchez, C.I.; Melendez, J.; Maduskar, P.; Story, A.; Hayward, A.; van Ginneken, B. Foreign object detection and removal to improve automated analysis of chest radiographs. Med. Phys. 2013, 40, 071901. [Google Scholar] [CrossRef]
  42. Schultheiss, M.; Schober, S.A.; Lodde, M.; Bodden, J.; Aichele, J.; Müller-Leisse, C.; Renger, B.; Pfeiffer, F.; Pfeiffer, D. A robust convolutional neural network for lung nodule detection in the presence of foreign bodies. Sci. Rep. 2020, 10, 1–9. [Google Scholar] [CrossRef]
  43. Deshpande, H.; Harder, T.; Saalbach, A.; Sawarkar, A.; Buelow, T. Detection of foreign objects in chest radiographs using deep learning. In Proceedings of the 2020 IEEE 17th International Symposium on Biomedical Imaging Workshops (ISBI Workshops), Iowa City, IA, USA, 4 April 2020; pp. 1–4. [Google Scholar]
  44. Santosh, K.; Dhar, M.K.; Rajbhandari, R.; Neupane, A. Deep neural network for foreign object detection in chest X-rays. In Proceedings of the 2020 IEEE 33rd International symposium on computer-based medical systems (CBMS), Rochester, MN, USA, 28–30 July 2020; 2020; pp. 538–541. [Google Scholar]
  45. Santosh, K.; Roy, S.; Allu, S. Generic Foreign Object Detection in Chest X-rays. In Proceedings of the Recent Trends in Image Processing and Pattern Recognition RTIP2R 2021 Communications in Computer and Information Science, TX, USA, 1–2 December 2022. [Google Scholar] [CrossRef]
  46. Demner-Fushman, D.; Kohli, M.D.; Rosenman, M.B.; Shooshan, S.E.; Rodriguez, L.; Antani, S.; Thoma, G.R.; McDonald, C.J. Preparing a collection of radiology examinations for distribution and retrieval. J. Am. Med. Inform. Assoc. 2016, 23, 304–310. [Google Scholar] [CrossRef] [Green Version]
  47. Demner-Fushman, D.; Antani, S.; Simpson, M.; Thoma, G.R. Design and development of a multimodal biomedical information retrieval system. J. Comput. Sci. Eng. 2012, 6, 168–177. [Google Scholar] [CrossRef] [Green Version]
  48. Story, A.; Murad, S.; Roberts, W.; Verheyen, M.; Hayward, A.C. Tuberculosis in London: The importance of homelessness, problem drug use and prison. Thorax 2007, 62, 667–671. [Google Scholar] [CrossRef]
Figure 1. Foreign objects (annotated/labeled) in chest X-rays: (a) jewelry and buttons, (b) ring, (c) pacemaker, and (d) medical tube.
Figure 1. Foreign objects (annotated/labeled) in chest X-rays: (a) jewelry and buttons, (b) ring, (c) pacemaker, and (d) medical tube.
Healthcare 11 00308 g001
Figure 2. Closer view of NBFO: (a) chain, (b) ring; and BFO: (c) medical device, (d) tube, (e)–(f) buttons, (g)–(h) pinnode.
Figure 2. Closer view of NBFO: (a) chain, (b) ring; and BFO: (c) medical device, (d) tube, (e)–(f) buttons, (g)–(h) pinnode.
Healthcare 11 00308 g002
Figure 3. Typical workflow of the AI-guided tools for foreign object (NBFO and BFO) classification/detection.
Figure 3. Typical workflow of the AI-guided tools for foreign object (NBFO and BFO) classification/detection.
Healthcare 11 00308 g003
Table 1. Foreign objects in chest X-rays (clinical observation) dataset (cases and subjects).
Table 1. Foreign objects in chest X-rays (clinical observation) dataset (cases and subjects).
AuthorsForeign ObjectsMethodDataset (Case)
(Subjects)
Brown et al. (2012) [16]Magnets and batteriesCase Study1 Subject
Pugmire et al. (2016) [17]Button BatteryReview276 cases
Fuentes et al. (2014) [18]Button BatteryReview and Case Study3 Cases and 29 Review
Meyer et al. (2020)) [20]Button Battery, Coins, Disk magnetsCase Study20 subjects
Thompson et al. (1989) [21]Cardiopulmonary devices Digital and Analog 40 subjects
Godoy et al. (2012) [22]Catheters, Pacemakers, Automatic implantable cardioverter defibrillators,
intra-aortic counter pulsation balloon pump, ventricular assist devices
Case Study-
Godoy et al. (2012) [23]Endotracheal and tracheostomy tubes, Chest tubes, and Nasogastric and Nasoenteric tubesCase Study-
Jennings et al. (1992) [24]Cardiopulmonary devicesPhosphor plate system50 subjects
Grier et al. (1990) [25]PacemakerCase Study600 subjects
Murthy et al. (2001) [26]Scarf pinCase Study6 subjects
Orgill et al. (2018) [27]Multi-layer metallic candy wrappersDuel-energy radio-graph1 subject
Huyett et al. (2018)) [31]CoinsCase Study4 subjects
Raney, Losek (2007)) [32]CoinsCase Study1 subject
Schlesinger, Crowe (2011) [35]CoinsCase Study8 subjects
Tander et al. (2009) [33]CoinsCase Study62 subjects
Ullal et al. (2018) [36]
Morrier et al. (2010) [37]
Foreign bodyCase Study150 subjects
Seed-migrationA gamma scintillation737 Subjects
Kero et al. (1983) [38]
Rybojad et al. (2012) [34]
Foreign bodiesCase Study57 subjects
Esophageal foreign bodiesChi-square test192 subjects
Table 2. NBFO and BFO in chest X-ray, dataset size, and performance measured in Performance, Recall, F1-score.
Table 2. NBFO and BFO in chest X-ray, dataset size, and performance measured in Performance, Recall, F1-score.
AuthorsNBFO, BFOMethodsDatasets
(Size of Images)
Performance (in %)
PrecisionRecallF1-Score
Xue et al. (2015) [39]ButtonsHand-crafted features5050.840.88-
Zohora, Santosh (2017) [2]Buttons, medical devicesHand-crafted features50100100-
Zohora, Santosh (2017) [40]Circular (buttons, medical devices)Hand-crafted features4000.960.900.92
Hogeweg et al. (2013) [41]Buttons, brassier clips, jewelry, or pacemakers and wireskNN classifier2570.949 (pixel level value)--
Schulthesiss et al. [42]Nodule detectionCNN (RatinaNet)411-0.87 (ROC)-
Santosh et al. (2020) [44]Circle like (e.g., coins/buttons)R-CNN4000.970.900.93
Santosh et al. (2022) [45]Buttons, coins, ring, pinnode, medical devices, tubeYOLOv44000.850.930.89
Table 3. Datasets.
Table 3. Datasets.
DatasetSizeAuthors
US NLM, National Institute of Health (Indiana Dataset)278Xue et al. (2015) [39]
US NLM, National Institute of Health50Zohora, Santosh (2017) [2]
US NLM, National Institute of Health400Zohora, Santosh (2017) [40]
Santosh et al. (2020,2022) [44,45]
Digital Diagnost Trixel, Philips Healthcare, the Netherlands257Hogeweg et al. (2013) [41]
Japanese Society of Radiological Technology (JSRT)411Schulthesiss et al. [42]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Roy, S.; Santosh, K. Analyzing Overlaid Foreign Objects in Chest X-rays—Clinical Significance and Artificial Intelligence Tools. Healthcare 2023, 11, 308. https://doi.org/10.3390/healthcare11030308

AMA Style

Roy S, Santosh K. Analyzing Overlaid Foreign Objects in Chest X-rays—Clinical Significance and Artificial Intelligence Tools. Healthcare. 2023; 11(3):308. https://doi.org/10.3390/healthcare11030308

Chicago/Turabian Style

Roy, Shotabdi, and KC Santosh. 2023. "Analyzing Overlaid Foreign Objects in Chest X-rays—Clinical Significance and Artificial Intelligence Tools" Healthcare 11, no. 3: 308. https://doi.org/10.3390/healthcare11030308