Review

Active Power Decoupling for Current Source Converters: An Overview Scenario

1
Department of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China
2
Department of Energy Technology, Aalborg University, 6700 Esbjerg, Denmark
*
Author to whom correspondence should be addressed.
Electronics 2019, 8(2), 197; https://doi.org/10.3390/electronics8020197
Submission received: 29 December 2018 / Revised: 1 February 2019 / Accepted: 2 February 2019 / Published: 8 February 2019
(This article belongs to the Special Issue Power Converters in Power Electronics)

Abstract

:
For single-phase current source converters, there is an inherent limitation in DC-side low-frequency power oscillation, which is twice the grid fundamental frequency. In practice, it transfers to the DC side and results in the low-frequency DC-link ripple. One possible solution is to install excessively large DC-link inductance for attenuating the ripple. However, it is of bulky size and not cost-effective. Another method is to use the passive LC branch for bypassing the power decoupling, but this is still not cost-effective due to the low-frequency LC circuit. Recently, active power decoupling techniques for the current source converters have been sparsely reported in literature. However, there has been no attempt to classify and understand them in a systematic way so far. In order to fill this gap, an overview of the active power decoupling for single-phase current source converters is presented in this paper. Systematic classification and comparison are provided for researchers and engineers to select the appropriate solutions for their specific applications.

1. Introduction

The current source converters have unique features, such as inherent short-circuit capability, no electrolytic capacitor, step-up voltage capability and high reliability, and they have been widely used in applications such as smart microgrids [1], industrial uninterrupted power supplies (UPS) [2], Superconductor Magnetic Energy Storage (SMES) [3], photovoltaic power systems [4], high voltage direct current (HVDC) transmission systems and flexible AC transmission (FACT) systems [5]. There are many key technique issues that need to be solved for the converter, such as the leakage current problem, the efficiency problem, and so on [6,7,8,9,10,11]. For the single-phase current source converter, there is an inherent limitation of AC-side low-frequency power oscillation, which is twice the grid fundamental frequency. It transfers to the DC side and results in the low-frequency DC-link ripple. It has many unfavorable disadvantages. For example, it may reduce the efficiency of the maximum power point (MPPT) tracking in photovoltaic applications. Therefore, it could lead the light emitting diode (LED) lamps to flicker [12]. In addition, it may cause the battery to overheat and reduce the life of fuel cells [13,14]. This is the reason why the power decoupling techniques are popular in both academic and industrial fields.
Basically, the above-mentioned power ripple can be attenuated by increasing the DC-link inductance. However, it is of bulky size and not cost-effective. Another method is to use the passive LC branch for bypassing the power ripple, but it is still not cost-effective due to the low-frequency LC circuit. Recently, active power decoupling techniques have been reported to deal with this problem. Many interesting topologies have been reported in the last decades [15,16,17,18,19,20,21,22,23,24]. For example, a buck type circuit, boost type circuit or buck-boost type circuit is applied as the auxiliary power decoupling circuit [25]. Another method reported in [26,27] uses two additional capacitors placed on the AC side to achieve power decoupling without any auxiliary switches. The decoupling topology using the center tap of the isolation transformer has been proposed [28,29,30]. The above-mentioned topologies are the voltage-source converters. On the other hand, the active power decoupling techniques for the current source converters have been sparsely discussed in the literature. For example, Sun et al. proposed an interesting circuit, which used a decoupling circuit connect in series with the main converter [31]. This power decoupling method has the advantage of control flexible. For the current source AC/DC/AC converter, the low-frequency ripple also exists on the DC-side. There is a kind of power decoupling circuit proposed in [32]. The capacitor is used as a power compensation component, while the H bridge circuit is applied for power decoupling. Another circuit in [33] uses the buffer capacitor to achieve the power decoupling on the DC-side. A circuit structure connected in parallel with the current source converter on the DC-side is proposed in [34]. For this circuit structure, the buffer capacitor also connects in series with the current source converter when the circuit works in power decoupling mode. Aside from that, the power decoupling circuit can be installed on the AC side [35], which needs an extra bridge arm. A similar circuit structure is proposed in [36,37,38]. A modified differential connected circuit structure is proposed in [39]. To decrease the number of auxiliary switches, a kind of power decoupling circuit with the lower switches multiplexing has been proposed [40]. The modified power decoupling circuits, which need no extra switch, are proposed in [41,42]. A decoupling topology using the isolation transformer for the current source converter is derived from [43]. The power decoupling circuit is independent with the main converter. However, it needs a transformer to isolate the decoupling circuit and the main current source converter.
In summary, the power decoupling method can be divided into the capacitive and inductive compensations [44]. For the active power decoupling for the current source converters, the capacitor is generally applied as the ripple power compensation device. According to the relation between the auxiliary power decoupling circuit and the main circuit, the ripple power decoupling circuit can be divided into independent and non-independent structures [45]. The following will present the details, and the rest of the paper is organized as follows. The theoretical analysis of power oscillation and ripple for the single-phase current source converter is presented in Section 2. The versatile power decoupling circuits are illustrated and discussed in Section 3 and Section 4. Aside from that, a comparison of different power decoupling circuits is provided in Section 5.

2. Problem Definition

The basic single-phase current source converter is illustrated in Figure 1.
In Figure 1, the grid voltage uac and grid current iac can be represented as:
u a c = V cos ( ω t ) ,
i a c = I cos ( ω t + φ ) ,
In Equation (2), φ represents the phase-angle between grid voltage and current. The output power Pac can be represented as
P a c = u a c i a c = V I cos ( φ ) 2 + V I cos ( 2 ω t + φ ) 2 ,
From (3), it can be observed that Pac has the ripple power at twice line frequency.
The constant power Po can be represented as:
P o = V I cos ( φ ) 2 ,
Therefore, the ripple power Pr can be represented as:
P r = V I cos ( 2 ω t + φ ) 2
According to the power conservation law, the ripple power also exists on the DC side.
Figure 2 reflects the relation between the output power and ripple power. The AC power Pac consists of the constant power Po and ripple power Pr. According to the power conservation law, the auxiliary circuit is needed to attenuate the ripple. When the AC power Pac is larger than power Po, the ripple power is absorbed by the compensating circuit. The auxiliary circuit will emit the energy to compensate the AC power Pac when the AC power Pac is less than Po. It is the basic mechanism for the power decoupling method.

3. DC-Side Power Decoupling Solutions

The structure shown in Figure 3a connects in series with the main converter on the DC side to compensate for the ripple power. The capacitor is used as a passive component to bypass the ripple power. The circuit shown in Figure 3b is a simplified circuit in which the number of the auxiliary switch is reduced. However, the complexity of the circuit control will increase.
The converter applies the H bridge structure shown in Figure 4. The voltage of the buffer capacitor is lower than the DC-side voltage. For this circuit, the circuit modes and power decoupling process is introduced as follows. When the auxiliary switches S5 and S6 are turned on, the buffer capacitor is charged. When switches S5 and S6 are turned off, the buffer capacitor discharges through the auxiliary diode D1 and D2. When only the switch S5 or S6 is turned on, the buffer capacitor is bypassed. The voltage of the buffer capacitor controlled to compensate the ripple power according the real time ripple power on the system. The auxiliary decoupling circuit is controlled independently with the main converter. For the function of the power decoupling circuit, the ripple power is eliminated on the DC side, and the DC-side inductance can be relatively small.
Another power decoupling circuit applying the series power decoupling circuit is proposed as shown in Figure 5. The AC/DC/AC converter has three bridge arms, which play the role of rectification and inversion with sharing a bridge arm. The bridge arm ‘a’ and bridge arm ‘c’ work as rectification. And the bridge arm ‘b’ and bridge arm ‘c’ work as inversion. The decoupling circuit is in series with the DC-link in which capacitor applied to compensate the ripple power.
Compared with a conventional AC/DC/AC converter, the circuit needs fewer switches. However, the system may be broken down when the auxiliary decoupling circuit is out of order, since the decoupling circuit is connected in series with the main circuit on the DC-side.
This type of power decoupling structure shown in Figure 3 has the advantages of a simple circuit structure, being independent with a main converter and flexible control. There are several other types of circuit structures, introduced as follow.
As shown in Figure 6, the auxiliary decoupling circuit is connected in parallel with the main converter. The buffer capacitor C is used to compensate the ripple power. Taking the positive period for example, the operation modes and power decoupling process are discussed as follows.
In the positive period, the switches S3 and S2 are turned off, the switches S1, S4 and extra switch S5 work to implement the energy transfer and power decoupling. When S5 is turned on and the capacitor voltage uc of C is lower than the grid voltage, the diode D2 will be turned on. The DC current will flow through the circuit consisting of switch S5 and diode D2. When S5 is turned on and the capacitor voltage of C is higher than the grid voltage, the diode D2 will turn off and the capacitor C will discharge connected in series with the main converter. When S5 is turned off and the main converter switches S1, S4 are turned off, the capacitor C is charged through the diodes D1 and D2. When S5 is turned off and the main converter switches S1 and S4 are turned on, the capacitor C is bypassed. Meanwhile, the grid current and the voltage of the power compensated capacitor are controlled. In contrast to the circuit structure shown in Figure 4, the auxiliary decoupling circuit is depended on the main converter. When the grid voltage is negative, the circuit state is similar with the positive period.
As shown in Figure 7, the auxiliary decoupling circuit consists of one bridge arm and a bidirectional buck-boost circuit, which work to compensate the ripple power. The voltage of capacitor Cf, is controlled to keep constant. The capacitor C is used to compensate the ripple power.
For this circuit, the operation modes and power decoupling process are discussed as follows. When all the main converter switches S1–S4 are turned off, the extra switch S5 remains on. In this state, the DC current is bypassed by the auxiliary bridge while the switch S6 is on. The buffer circuit supplies zero voltage to the DC side. While switch S6 is turned off, the buffer circuit connects in series with the DC side to compensate the ripple power. When the main converter switches S1 and S4 (or S2 and S3) are turned on, the switch S5 keep off. In this state, when switch S6 is turned off, the buffer circuit is isolated with the source. When switch S6 is turned on, the buffer circuit connects in series with DC side. The switch states of S5 and S6 are dependent with the main circuit.
The decoupling circuit shown in Figure 6 and Figure 7 connects in parallel with the main converter but the buffer capacitor is connected in series with the main converter.

4. The Typical Circuit Structure of AC Side Decoupling

An interesting circuit structure to decouple the ripple power on the AC side is proposed in [35].
As shown in Figure 8, there is an auxiliary bridge arm of the converter. The capacitor C1, C2 and C3 work as power compensation capacitor connected in star structure. The capacitor C2 and C3 also work as AC filter capacitor. To compensate the ripple power, the decoupling circuit shares two arm bridges with the main converter to control the capacitor voltage effectively. The circuit shown in Figure 9 is one of the simplified circuits.
The decoupling capacitor C3 of Figure 8 can be seen as a wire in the circuit of Figure 9. The decoupling capacitor C1 works as the AC filter capacitor.
The literature [36] introduces a circuit which also compensates the ripple power on the AC-side. It is a duality with the voltage source converter introduced in [37]. It is similar to Figure 9 in circuit structure.
As shown in Figure 10, the circuit topology consists of three bridge arms. The bridge arm ’b’ is connected with bridge arm ‘c’ through buffer capacitor C. By controlling the current flowing through capacitor C, the ripple power can be compensated. Different from the circuit shown in Figure 9, the circuit only has one decoupling capacitor. Hence, it is easy to control.
For the single-phase current source AC/DC/AC converter, the ripple power exists at the source and load sides. To eliminate the low frequency DC-link energy, an interesting circuit is proposed in [38], as shown in Figure 11. The auxiliary power decoupling circuits were applied on the AC side to compensate for the ripple power, which is similar to the decoupling method shown in Figure 10. Compared with the power decoupling method shown in Figure 11, this circuit needs more extra switches. Henceforth, it has more switch losses.
A kind of differently-connected circuit was applied to achieve the ripple power decoupling as shown in Figure 12a.
As shown in Figure 12a, the current source inverter is composed of two H-type inverter which is connected in a differential way. The power decoupling circuit applies two capacitors as the power compensation device, which is placed at AC side. The number of switches is high as shown in Figure 12a. A modified circuit structure is proposed in [39]. The middle two bridge arms of Figure 12a were synthesized into one bridge arm, as shown in Figure 12b. The power compensation capacitors C1 and C2 shown in Figure 12b were used also as the AC filter capacitors. The phase of the ripple voltage part of the two capacitors was reversed. So, the total voltage of the two capacitors synchronizes with the grid voltage.
As stated above, the auxiliary power decoupling circuit shares the bridge arm with the main converter. The decoupling circuit, which shares the lower switches with the main inverter is proposed in [40]. As shown in Figure 13, the decoupling circuit part is marked by the lower dotted line. The main converter is marked by the upper dotted line. It is obvious that the multiplexed switches are the lower switches of the main converter. Compared to a conventional independent circuit, the dependent circuit needs fewer switches. To decrease the number of extra switches, the modified circuit of Figure 13 is proposed in [41,42].
As shown in Figure 14a, there is an auxiliary capacitor which connects between the bridge arms. There are two circuit states to charge the capacitor voltage. When the switches S1, S3 and S4 are turned on, the capacitor C is charged. While the switch S2 is turned on, the capacitor C discharged. The voltage of capacitor C is controlled to compensate for the ripple power. This circuit only needs one auxiliary diode to limit the discharging loop of the buffer capacitor. Compared with Figure 14a, the circuit shown in Figure 14b has two auxiliary capacitors. Thus, the circuit has more optional circuit states.
A decoupling topology using the isolation transformer for current source converter is derived from [43]. In Figure 15, it can be observed that the auxiliary power decoupling circuit is separated from the output circuit. The auxiliary power decoupling circuit is independent from the main converter. Compared to the dependent power decoupling circuit, control of independent circuit is simple. However, it needs more auxiliary switches and an extra transformer.

5. Discussions and Conclusions

The ripple power in the single-phase current source converter has an adverse effect on the performance of the system. That is the reason why power decoupling is important for single-phase current source converters. This paper has presented a systematic review of the power decoupling methods for single-phase current source converters. Typically, the capacitor is used as a buffer device for power decoupling [46,47,48,49]. According the relationship between the decoupling circuit and the main converter, the topology is divided into the independent and the dependent circuits. The dependent circuit needs few auxiliary switches. However, it is complex to control. The decoupling circuit can be placed on the DC-side or AC-side of the main converter. One of the DC-side decoupling circuits is shown in Figure 4. The H-bridge decoupling circuit is connected in series with the main converter. For this circuit structure, the power decoupling circuit is controlled independently with the main converter. Other circuit structures for DC-side power decoupling are shown in Figure 6 and Figure 7. The auxiliary power decoupling circuit is in parallel with the main converter. The AC-side decoupling circuit shares bridge arms with the main converter. The typical structure is described as follows.
The circuit structure in Figure 16a needs two or more buffer capacitors to decouple the ripple power. The typical circuit structures are shown in Figure 8, Figure 9 and Figure 12. The circuit structures in Figure 9 and Figure 12 can be considered as the simplified circuit of Figure 8. For the circuit structure shown in Figure 16b, the decoupling circuit shares a bridge arm with the main converter. The typical circuit is shown as Figure 10. Only one buffer capacitor is needed for power decoupling. It can be considered similar to the circuit structure in Figure 8.
Regarding the two circuit structures shown above, the decoupling circuit is dependent on the main converter. They will interfere with each other, which results in output current distortion and increases the control complexity.
A comparison of these topologies is shown in Table 1. The structures of power decoupling circuits have different characteristics. For example, compared to the dependent decoupling circuit, the independent decoupling circuit is not influenced by the main converter. However, the independent decoupling circuit needs more extra switches. Readers might wonder which could be the best choice among these versatile solutions. The answer to this question is difficult because each of them has its own disadvantages and advantages. In this paper, an overview and comparison has carried out, and it is expected to provide a useful guide for researchers and engineers to select the appropriate power decoupling solution for their specific applications.

Author Contributions

This paper was a collaborative effort among all authors.

Funding

This work is supported by the National Natural Science Foundation of China (51777181), the Lite-On Research Funding, the State Key Laboratory of Reliability and Intelligence of Electrical Equipment (No. EERIKF2018002), Hebei University of Technology, Postdoctoral Research Program of Hebei Province (B2018003010), and Hundred Excellent Innovation Talents Support Program of Hebei Province (SLRC2017059).

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

Acronyms
ADactive damping
UPSuninterruptible power supply
SMESsuperconductor magnetic energy storage
HVDChigh voltage direct current
FACTflexible AC transmission
MPPTmaximum power point tracking
LEDlight emitting diode
Nomenclature
uacgrid voltage
iacgrid current
φphase-angle between grid voltage and current
Pacoutput power
Poconstant power
Prripple power

References

  1. Senthilnathan, K.; Annapoorani, I. Multi-Port Current Source Inverter for Smart Microgrid Applications: A Cyber Physical Paradigm. Electronics 2019, 8, 1. [Google Scholar] [CrossRef]
  2. Colombi, S.; Balblano, C. Clean Input UPS with Fast Rectifier Control and Improved Battery Life. U.S. Patent US7768805, 3 August 2010. [Google Scholar]
  3. Wang, Z.; Jiang, L.; Zou, Z.; Cheng, M. Operation of SMES for the current source inverter fed distributed power system under islanding mode. IEEE Trans. Appl. Superconduct. 2012, 23, 5700404. [Google Scholar] [CrossRef]
  4. Guo, X. A novel CH5 inverter for single-phase transformerless photovoltaic system applications. IEEE Trans. Circ. Syst. II Express Briefs 2017, 64, 1197–1201. [Google Scholar] [CrossRef]
  5. Liang, J.; Nami, A.; Dijkhuizen, F.; Tenca, P.; Sastry, J. Current source modular multilevel converter for HVDC and FACTS. In Proceedings of the European Conference on Power Electronics and Applications, Lille, France, 2–6 September 2013; pp. 1–10. [Google Scholar]
  6. Kerekes, T.; Teodorescu, R.; Liserre, M.; Klumpner, C.; Sumner, M. Evaluation of Three-Phase Transformerless Photovoltaic Inverter Topologies. IEEE Trans. Power Electron. 2009, 24, 2202–2211. [Google Scholar] [CrossRef]
  7. Graditi, G.; Adinolfi, G.; Femia, N.; Vitelli, M. Comparative analysis of Synchronous Rectification Boost and Diode Rectification Boost converter for DMPPT applications. In Proceedings of the 2011 IEEE International Symposium on Industrial Electronics, Gdansk, Poland, 27–30 June 2011; pp. 1000–1005. [Google Scholar]
  8. Yang, B.; Li, W.; Gu, Y.; Cui, W.; He, X. Improved Transformerless Inverter with Common-Mode Leakage Current Elimination for a Photovoltaic Grid-Connected Power System. IEEE Trans. Power Electron. 2012, 27, 752–762. [Google Scholar] [CrossRef]
  9. Cecati, C.; Khalid, H.A.; Tinari, M.; Adinolfi, G.; Graditi, G. DC NanoGrid with Renewable Energy Sources and Modular DC/DC LLC Converter Building Block. IET Power Electron. 2016, 10, 536–544. [Google Scholar] [CrossRef]
  10. Adinolfi, G.; Graditi, G.; Siano, P.; Piccolo, A. Multi-Objective Optimal Design of Photovoltaic Synchronous Boost Converters Assessing Efficiency, Reliability and Cost Savings. IEEE Trans. Ind. Inform. 2015, 11, 1038–1048. [Google Scholar] [CrossRef]
  11. Cavalcanti, M.C.; De Oliveira, K.C.; De Farias, A.M.; Neves, F.A.; Azevedo, G.M.; Camboim, F.C. Modulation Techniques to Eliminate Leakage Currents in Transformerless Three-Phase Photovoltaic Systems. IEEE Trans. Ind. Electron. 2010, 57, 1360–1368. [Google Scholar] [CrossRef]
  12. Chen, W.; Hui, S.R. Elimination of an electrolytic capacitor in AC/DC light-emitting diode (LED) driver with high input power factor and constant output current. IEEE Trans. Power Electron. 2011, 27, 1598–1607. [Google Scholar] [CrossRef]
  13. Kim, H.; Shin, K.G. DESA: Dependable, Efficient, Scalable Architecture for management of large-scale batteries. IEEE Trans. Ind. Inform. 2011, 8, 406–417. [Google Scholar] [CrossRef]
  14. Shimizu, T.; Fujita, T.; Kimura, G.; Hirose, J. A unity power factor PWM rectifier with DC ripple compensation. IEEE Trans. Ind. Electron. 1997, 44, 447–455. [Google Scholar] [CrossRef]
  15. Hu, H.; Harb, S.; Kutkut, N.; Batarseh, I.; Shen, Z.J. A review of power decoupling techniques for microinverters with three different decoupling capacitor locations in PV systems. IEEE Trans. Power Electron. 2012, 28, 2711–2726. [Google Scholar] [CrossRef]
  16. Guo, X.; Zhang, X.; Guan, H.; Kerekes, T.; Blaabjerg, F. Three phase ZVR topology and modulation strategy for transformerless PV system. IEEE Trans. Power Electron. 2019, 34, 1017–1021. [Google Scholar] [CrossRef]
  17. Schimpf, F.; Norum, L. Effective use of film capacitors in single-phase PV-inverters by active power decoupling. In Proceedings of the 36th Annual Conference on IEEE Industrial Electronics Society, Glendale, AZ, USA, 7–10 November 2010; pp. 2784–2789. [Google Scholar]
  18. Yang, Y.; Ruan, X.; Zhang, L.; He, J.; Ye, Z. Feed-forward scheme for an electrolytic capacitor-less AC/DC LED driver to reduce output current ripple. IEEE Trans. Power Electron. 2014, 29, 5508–5517. [Google Scholar] [CrossRef]
  19. Cao, X.; Zhong, Q.; Ming, W. Ripple eliminator to smooth DC-Bus voltage and reduce the total capacitance required. IEEE Trans. Power Electron. 2015, 62, 2224–2235. [Google Scholar] [CrossRef]
  20. Krein, P.T.; Balog, R.S.; Mirjafari, M. Minimum energy and capacitance requirements for single-phase inverters and rectifiers using a ripple port. IEEE Trans. Power Electron. 2012, 27, 4690–4698. [Google Scholar] [CrossRef]
  21. Harb, S.; Mirjafari, M.; Balog, R.S. Ripple-port module-integrated inverter for grid-connected PV applications. IEEE Trans. Ind. Appl. 2013, 49, 2692–2698. [Google Scholar] [CrossRef]
  22. Nussbaumer, T.; Kolar, J.W. Improving mains current quality for three-phase three-switch buck-type PWM rectifiers. IEEE Trans. Power Electron. 2006, 21, 967–973. [Google Scholar] [CrossRef]
  23. Guo, X.; Yang, Y.; Zhu, T. ESI: A novel three-phase inverter with leakage current attenuation for transformerless PV systems. IEEE Trans. Ind. Electron. 2018, 65, 2967–2974. [Google Scholar] [CrossRef]
  24. Nussbaumer, T.; Baumann, M.; Kolar, J.W. Comprehensive design of a three-phase three-switch buck-type PWM rectifier. IEEE Trans. Power Electron. 2007, 22, 551–562. [Google Scholar] [CrossRef]
  25. Tang, Y.; Blaabjerg, F.; Loh, P.C.; Jin, C.; Wang, P. Decoupling of fluctuating power in single-phase systems through a symmetrical half-bridge circuit. IEEE Trans. Power Electron. 2015, 30, 1855–1865. [Google Scholar] [CrossRef]
  26. Serban, I. A novel transistor-less power decoupling solution for single-phase inverters. In Proceedings of the 39th Annual Conference of the IEEE Industrial Electronics Society, Vienna, Austria, 10–13 November 2013; pp. 1496–1500. [Google Scholar]
  27. Tang, Y.; Yao, W.; Wang, H.; Loh, P.C.; Blaabjerg, F. Transformerless photovoltaic inverters with leakage current and pulsating power elimination. In Proceedings of the 9th International Conference on Power Electronics and ECCE Asia, Seoul, Korea, 1–5 June 2015; pp. 115–122. [Google Scholar]
  28. Hu, H.; Harb, S.; Kutkut, N.; Batarseh, I.; Shen, Z.J. Power decoupling techniques for micro-inverters in PV systems-a review. In Proceedings of the 2010 IEEE Energy Conversion Congress and Exposition, Atlanta, GA, USA, 12–16 September 2010; pp. 3235–3240. [Google Scholar]
  29. Takahashi, H.; Takaoka, N.; Gutierrez, R.R.R.; Itoh, J.-I. Power decoupling method for isolated dc to single-phase ac converter using matrix converter. In Proceedings of the 20th European Conference on Power Electronics and Applications, Riga, Latvia, 17–21 September 2018; pp. 1–10. [Google Scholar]
  30. Cai, W.; Liu, B.; Duan, S.; Jiang, L. Power flow control and optimization of a three-port converter for photovoltaic-storage hybrid system. In Proceedings of the IEEE Energy Conversion Congress and Exposition, Raleigh, NC, USA, 15–20 September 2012; pp. 4121–4128. [Google Scholar]
  31. Han, H.; Liu, Y.; Sun, Y.; Su, M.; Xiong, W. Single-phase current source converter with power decoupling capability using a series-connected active buffer. IET Power Electron. 2015, 8, 700–707. [Google Scholar] [CrossRef]
  32. Liu, Y.; Sun, Y.; Su, M.; Li, X.; Ning, S. A Single Phase AC/DC/AC Converter with Unified Ripple Power Decoupling. IET Power Electron. 2018, 33, 3204–3217. [Google Scholar] [CrossRef]
  33. Ohnuma, Y.; Orikawa, K.; Itoh, J.I. A single-phase current source PV inverter with power decoupling capability using an active buffer. IEEE Trans. Ind. Appl. 2014, 51, 531–538. [Google Scholar] [CrossRef]
  34. Román, L.T.; Silva, L.S. A single-phase current-source inverter with active power filters for grid-tied PV systems. In Proceedings of the 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems, Aalborg, Denmark, 25–28 June 2012; pp. 349–356. [Google Scholar]
  35. Wei, L.; Skibinski, G.L.; Lukaszewski, R.A. Auxiliary Circuit for Use with Three-Phase Drive with Current Source Inverter Powering a Single-Phase Load. U.S. Patent 7518891B2, 14 April 2009. [Google Scholar]
  36. Vitorino, M.A.; Correa, M.B.D.R. Compensation of DC link oscillation in single-phase VSI and CSI converters for photovoltaic grid connection. IEEE Trans. Ind. Appl. 2014, 50, 2021–2028. [Google Scholar] [CrossRef]
  37. Su, M.; Pan, P.; Long, X.; Sun, Y.; Yang, J. An active power-decoupling method for single-phase AC-DC converters. IEEE Trans. Ind. Inf. 2014, 10, 461–468. [Google Scholar] [CrossRef]
  38. Vitorino, M.A.; Wang, R.; de Rossiter Corrêa, M.B.; Boroyevich, D. Compensation of DC-Link Oscillation in Single-Phase-to-Single-Phase VSC/CSC and Power Density Comparison. IET Power Electron. 2014, 50, 2021–2028. [Google Scholar] [CrossRef]
  39. Vitorino, M.A.; Correa, M.B.R.; Jacobina, C.B. Single-phase power compensation in a current source converter. In Proceedings of the 2013 IEEE Energy Conversion Congress and Exposition, Denver, CO, USA, 15–19 September 2013; pp. 5288–5293. [Google Scholar]
  40. Vitorino, M.A.; Hartmann, L.V.; Fernandes, D.A.; Silva, L.E.; Correa, M.B.R. Single-phase current source converter with new modulation approach and power decoupling. IEEE Appl. Power Electron. Conf. Expo. 2014, 16, 2200–2207. [Google Scholar]
  41. Liu, Y.; Sun, Y.; Su, M. Active power compensation method for single-phase current source rectifier without extra active switches. IET Power Electron. 2016, 9, 1719–1726. [Google Scholar] [CrossRef]
  42. Sun, Y.; Liu, Y.; Su, M. Active power decoupling method for single-phase current-source rectifer with no additional active switches. IEEE Trans. Power Electron. 2016, 31, 5644–5653. [Google Scholar] [CrossRef]
  43. Itoh, J.I.; Fayashi, F. Ripple current reduction of a fuel cell for a single-phase isolated converter using a dc active filter with a center tap. IEEE Trans. Power Electron. 2010, 25, 550–556. [Google Scholar] [CrossRef]
  44. Larsson, T.; Ostlund, S. Active DC link filter for two frequency electric locomotives. In Proceedings of the International Conference on Electric Railways in a United Europe, Amsterdam, The Netherlands, 27–30 March 1995; pp. 97–100. [Google Scholar]
  45. Cai, W.; Jiang, L.; Liu, B.; Zou, C. A power decoupling method based on four-switch three-port DC/DC/AC converter in dc microgrid. IEEE Trans. Ind. Appl. 2015, 51, 336–343. [Google Scholar] [CrossRef]
  46. Shimizu, T.; Fujioka, Y.; Kimura, G. DC ripples current reduction method on a single phase PWM voltage source converter. In Proceedings of the IEEE Power Conversion Conference, Nagaoka, Japan, 6 August 1998; Volume 1, pp. 525–530. [Google Scholar]
  47. Shimizu, T.; Jin, Y.; Kimura, G. DC ripple current reduction on a single-phase PWM voltage-source rectifier. IEEE Trans. Ind. Appl. 2000, 36, 1419–1429. [Google Scholar] [CrossRef]
  48. Guo, X.; Yang, Y.; Wang, X. Optimal space vector modulation of current source converter for dc-link current ripple reduction. IEEE Trans. Ind. Electron. 2019, 66, 1671–1680. [Google Scholar] [CrossRef]
  49. Tsuno, K.; Shimizu, T.; Wada, K.; Ishii, K. Optimization of the DC ripples energy compensating circuit on a single-phase voltage source PWM rectifier. In Proceedings of the IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551), Aachen, Germany, 20–25 June 2004; pp. 316–321. [Google Scholar]
Figure 1. Basic single-phase current source converter.
Figure 1. Basic single-phase current source converter.
Electronics 08 00197 g001
Figure 2. Output power and ripple power.
Figure 2. Output power and ripple power.
Electronics 08 00197 g002
Figure 3. (a) H-bridge decoupling circuit; (b) Simplified H-bridge decoupling circuit.
Figure 3. (a) H-bridge decoupling circuit; (b) Simplified H-bridge decoupling circuit.
Electronics 08 00197 g003
Figure 4. Power decoupling solution in [31].
Figure 4. Power decoupling solution in [31].
Electronics 08 00197 g004
Figure 5. Power decoupling solution in [32].
Figure 5. Power decoupling solution in [32].
Electronics 08 00197 g005
Figure 6. Power decoupling solution in [33].
Figure 6. Power decoupling solution in [33].
Electronics 08 00197 g006
Figure 7. Power decoupling solution in [34].
Figure 7. Power decoupling solution in [34].
Electronics 08 00197 g007
Figure 8. Power decoupling solution in [35].
Figure 8. Power decoupling solution in [35].
Electronics 08 00197 g008
Figure 9. Power decoupling solution in [35].
Figure 9. Power decoupling solution in [35].
Electronics 08 00197 g009
Figure 10. Power decoupling solution in [36].
Figure 10. Power decoupling solution in [36].
Electronics 08 00197 g010
Figure 11. Current source converter with two auxiliary decoupling circuits [38].
Figure 11. Current source converter with two auxiliary decoupling circuits [38].
Electronics 08 00197 g011
Figure 12. Topology of current source converter with differential-connected structure [39]. (a) four leg configuration; (b) three leg configuration.
Figure 12. Topology of current source converter with differential-connected structure [39]. (a) four leg configuration; (b) three leg configuration.
Electronics 08 00197 g012
Figure 13. Power decoupling solution in [40].
Figure 13. Power decoupling solution in [40].
Electronics 08 00197 g013
Figure 14. Power decoupling solution with no auxiliary switch [41,42]. (a) 1-capacitor configuration; (b) 2-capacitor configuration.
Figure 14. Power decoupling solution with no auxiliary switch [41,42]. (a) 1-capacitor configuration; (b) 2-capacitor configuration.
Electronics 08 00197 g014
Figure 15. Power decoupling solution with three-port circuit [43].
Figure 15. Power decoupling solution with three-port circuit [43].
Electronics 08 00197 g015
Figure 16. AC-side power decoupling circuit structure. (a) Share two bridge arms; (b) Share a bridge arm; (c) Three-port circuit.
Figure 16. AC-side power decoupling circuit structure. (a) Share two bridge arms; (b) Share a bridge arm; (c) Three-port circuit.
Electronics 08 00197 g016aElectronics 08 00197 g016b
Table 1. Comparison of versatile power decoupling circuits.
Table 1. Comparison of versatile power decoupling circuits.
Power RatingAuxiliary ComponentsConnection MethodCircuit PerformanceAdvantages and Disadvantages
Figure 4 [31]139.2 W1 Capacitor (91.8 µF) + 2 Switches + 2 DiodesIn series
(DC side)
Efficiency: 84%.
Effect: Second-order harmonic current ripple is reduced by 87.99%.
Dynamic response: within 5 ms.
Advantages: Easy control and simple circuit structure.
Disadvantages: Endangering the system stability due to the connected power decoupling circuit.
Figure 5 [32]300 W1 Capacitor (100 µF) + 2 Switches + 2 DiodesIn series
(DC side)
Effect: Second-order harmonic current ripple reduced to 1.72% of DC link current.
Dynamic response: within 1 ms.
Advantage: Less auxiliary switches
Disadvantages: Control is complex,
Endangering the system stability due to connected power decoupling circuit
Figure 6 [33]500 W1 Capacitor (50 µF) + 1 Switch + 2 DiodesIn parallel
(DC side)
THD: Less than 5%. The output power factor can reach to 99.9%
Efficiency: Maximum efficiency of 94.9%
Effect: Voltage ripple is reduced to 8.87%
Advantages: System stability.
Disadvantage: Control is complex.
Figure 7 [34]/1 Capacitor + 4 Switches + 1 DiodesIn parallel
(DC side)
Effect: MPPT performance can be improved for the PV converter.Advantages: System stability.
Disadvantage: Circuit structure complex, Much auxiliary switch.
Figure 8 [35]/3 Capacitors + 2 SwitchesIn parallel
(AC side)
/Advantage: Bridge arms multiplexing, Less auxiliary switches
Disadvantage: Control is complex.
Figure 9 [35]2 Capacitors + 2 SwitchesIn parallel
(AC side)
Figure 10 [36]1 kW1 Capacitor (10 µF) + 2 SwitchesIn parallel
(AC side)
Effect: The input current ripple is reduced to 1.86% of DC-link current.Advantages: Bridge arms multiplexing, Control is easy relatively.
Disadvantage: Control is complex.
Figure 11 [38]515 W2 Capacitor (100 µF, 100 µF) + 4 SwitchesIn parallel
(AC side)
Efficiency: 85.05%.
Effect: The input voltage ripple is reduced to 3.9% of DC-link voltage.
Advantage: Simple control.
Disadvantages: Extra switches for decoupling circuits exist on both AC-sides.
Figure 12b [39]1 kW2 Capacitors (32 µF, 32 µF) + 2 SwitchesIn parallel
(AC side)
Effect: The input current ripple is reduced to 3% of DC-link current.Advantage: Bridge arm multiplexing.
Disadvantage: Control is complex.
Figure 13 [40]1 kW1 Capacitor (50 µF) + 2 Switches/Effect: The input current ripple is reduced to 4.275% of DC-link current. The input voltage ripple can be reduced to 8.6% of DC-link voltage.Advantage: Switch multiplexing.
Disadvantages: Endangering system stability due to a bridge arm with three switches.
Figure 14a [41]217.5 W1 Capacitor (90 µF)/THD: 4.63%.
Efficiency: The power losses caused by decoupling circuit is about 1.5%
Dynamic response: within 1 ms.
Advantage: No extra switches.
Disadvantage: Control is complex.
Figure 14b [42]217.5 W2 Capacitors (90 µF total)/THD: 4.47%.
Effect: Second-order harmonic current ripple is reduced to 2.36%
Dynamic response: within 1 ms.
Advantages: No extra switches, More optional circuit states.
Disadvantage: complex control
Figure 15 [43]/1 Capacitor + 4 switches + transformerIsolated with main converter
(AC side)
Efficiency: The power losses are high due to the losses of auxiliary switches and transformer.Advantage: Independent structure.
Disadvantages: Need a transformer, high power loss.

Share and Cite

MDPI and ACS Style

Zhang, J.; Ding, H.; Wang, B.; Guo, X.; Padmanaban, S. Active Power Decoupling for Current Source Converters: An Overview Scenario. Electronics 2019, 8, 197. https://doi.org/10.3390/electronics8020197

AMA Style

Zhang J, Ding H, Wang B, Guo X, Padmanaban S. Active Power Decoupling for Current Source Converters: An Overview Scenario. Electronics. 2019; 8(2):197. https://doi.org/10.3390/electronics8020197

Chicago/Turabian Style

Zhang, Jianhua, Hao Ding, Baocheng Wang, Xiaoqiang Guo, and Sanjeevikumar Padmanaban. 2019. "Active Power Decoupling for Current Source Converters: An Overview Scenario" Electronics 8, no. 2: 197. https://doi.org/10.3390/electronics8020197

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop