Next Article in Journal
Design of Military Service Framework for Enabling Migration to Military SaaS Cloud Environment
Next Article in Special Issue
State-of-the-Art Optical Devices for Biomedical Sensing Applications—A Review
Previous Article in Journal
A Comparative Experimental Study of MIMO A&F and D&F Relay Nodes Using a Software-Defined Radio Platform
Previous Article in Special Issue
Multi-Channel Transfer Learning of Chest X-ray Images for Screening of COVID-19
 
 
Article
Peer-Review Record

Algorithm for Automated Foot Detection in Thermal and Optical Images for Temperature Asymmetry Analysis

Electronics 2021, 10(5), 571; https://doi.org/10.3390/electronics10050571
by Jonas Guzaitis 1, Agne Kadusauskiene 2,* and Renaldas Raisutis 3
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Electronics 2021, 10(5), 571; https://doi.org/10.3390/electronics10050571
Submission received: 2 February 2021 / Revised: 22 February 2021 / Accepted: 23 February 2021 / Published: 28 February 2021
(This article belongs to the Special Issue Optical Sensing for Biomedical Applications)

Round 1

Reviewer 1 Report

The paper entitled "Algorithm for automated foot detection in thermal and optical images for temperatures asymmetry analysis" aims at presenting a methodology allowing to detect abnormal thermal field on a foot. To do so, the method relies on 1) the feet edge detection, 2) the thermal field interpolation on points of interest, 3) the creation of a disparity map between the two feet and 4) the comparison of the disparity with a threshold value to detect abnormal zone.

The paper is well written and the methods used are quite well described. Nevertheless, some precision have to be added in order to help the comprehension:

  • the Figure 3 is difficult to understand, as different number seem to point toward the same object which complicate the comprehension of the method
  • it seems that the disparity field is built on by performing the difference between the temperature at two corresponding point-of-interest belonging to each foot. But is it exact? 
  • what happened if the temperature is abnormal in both foot at the same point-of-interest? Does it perturbe the detection?
  • it is not precised how the inflammation zone is attibuted to one foot or the other, supposingly according to the sign of the disparity value but it has to be noticed.

 

Author Response

"Please see the attachment." 

Author Response File: Author Response.pdf

Reviewer 2 Report

-please add colorful picture of measurements (optionally);;;?
-please add block diagram of the proposed research step by step ;;; what is the result of paper?;;;
-please add block diagram of the proposed method;;;
-please add photo/photos of application of the proposed research ;;;; 
-please add sentences about future analysis;;;
-Figures should have better quality;;;; for now they are low
-formulas should be formatted;;;;
-too many formulas, it is better to add block diagrams;;;;;
-Fonts of figures should be bigger;;;
-references should be 2018-2021 Web of Science about 50% or more ;;
-Please compare with other methods, justify. Advantages or Disadvantages thermal imaging;;
for example:

1) Fault diagnosis of electric impact drills using thermal imaging, Measurement, Volume 171, 2021, 
https://doi.org/10.1016/j.measurement.2020.108815

-Conclusion: point out what are you done;;;;
-is there possibility to use the proposed method for other problems?

Author Response

"Please see the attachment." 

Author Response File: Author Response.pdf

Round 2

Reviewer 2 Report

-it is good idea to compare the proposed method with other medical problems, add photos etc.

Author Response

"Please see the attachment." 

Author Response File: Author Response.pdf

This manuscript is a resubmission of an earlier submission. The following is a list of the peer review reports and author responses from that submission.