Next Article in Journal
Risk of Acute Myocardial Infarction in Patients with Gastroenteritis: A Nationwide Case-Control Study
Previous Article in Journal
Thyroid Function Alteration in Obesity and the Effect of Bariatric Surgery
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Innovative Medial Cushioning Orthoses Affect Peroneus Longus Electromyographic Activity during Running

by
Ruben Sanchez-Gomez
1,*,
Alvaro Gomez-Carrion
1,
Carlos Martinez-Sebastian
1,
Luis Alou
2,
David Sevillano
2,
Almudena Nuñez-Fernandez
1,
Paola Sanz-Wozniak
1 and
Blanca de la Cruz-Torres
3
1
Nursing Department, Faculty of Nursing, Physiotherapy and Podiatry, Universidad Complutense de Madrid, 28040 Madrid, Spain
2
Microbiology Division, Department of Medicine, Universidad Complutense de Madrid, 28040 Madrid, Spain
3
Department of Physiotherapy, University of Seville, 41009 Seville, Spain
*
Author to whom correspondence should be addressed.
J. Clin. Med. 2022, 11(5), 1339; https://doi.org/10.3390/jcm11051339
Submission received: 17 January 2022 / Revised: 11 February 2022 / Accepted: 25 February 2022 / Published: 28 February 2022

Abstract

:
Background: Over-supination processes of the foot and ankle involving peroneus longus (PL) damage during running sports have been treated conservatively with passive control tools, such as tapes, braces, or external ankle supports, but the effect of orthoses with typical lateral wedging orthoses (TLWO) on the muscular activity of PL during running remains unclear. Here we investigate the effects of innovative medial cushioning orthoses (IMCO) on PL activity during the full running gait cycle. In addition, we wished to ascertain the effects of innovative medial cushioning orthoses (IMCO) on PL activity during running. Methods: Thirty-one healthy recreational runners (mean age 34.5 ± 3.33) with neutral foot posture index scores, were selected to participate in the present study. They ran on a treadmill at 9 km/h wearing seven different orthoses (NRS, IMCO 3 mm, IMCO 6 mm, IMCO 9 mm, TLWO 3 mm, TLWO 6 mm and TLWO 9 mm), randomly performed on the same day while electromyographic activity of the PL muscle was recorded. Statistical intraclass correlation coefficient (ICC) to test reliability was carried out and the Wilcoxon test with Bonferroni’s correction was developed to analyze the differences between the conditions. Results: the reliability of all assessments showed data higher than 0.81, that is, “almost perfect reliability”; all EMG PL values wearing either TLWO or IMCO showed a statistically significant reduction versus NRS during the fully analyzed running gait cycle; the highest difference was set on NRS 23.08 ± 6.67 to TLWO 9 mm 17.77 ± 4.794 (p < 0.001). Conclusions: Muscular EMG activity of the PL during the full running gait cycle decreases when wearing either TLWO or IMCO relative to NRS; therefore, these orthoses could be prescribed to treat the strain and overload pathologies of PL. In addition, IMCO—as it less thick, compared with TLWO—can be used when aiming to achieve better running economy.

1. Introduction

Lateral ankle sprains and peroneal tendon disorders are common pathologies among recreational runners [1]. The lateral ligament complex and peroneus apparatus contribute to countering the normal supination moments in the first phase of the human gait [2], named the heel contact phase. There are multiple conservative interventions to treat lateral ligament ankle disorders, depending on the ankle sprain level and phase of its evolution [3]: compression, ice, non-steroidal anti-inflammatory medications, elevation and rest are prescribed to avoid swelling and to reduce the pain in the first inflammation phase; during the second proliferation phase, motion rehabilitation to recover the normal range of motion; and in the third phase, neuromodulation and strengthening to reach the normal level of sport competition or daily activity [4]. Furthermore, external ankle supports (such as an ankle brace or tape) for up to 1 year after an ankle sprain have been used to assist functional rehabilitation in runners [5,6]. However, plantar foot orthoses have not been considered as part of the efforts to quickly improve these ligament issues.
In addition to ankle ligament injuries, peroneal longus (PL) tendon damage is known to occur when a lateral ankle sprain is present and in over-supinated feet or hindfeet varus [7]. Those with chronic lateral ankle instability have higher PL electromyographic (EMG) activity than neutrals [8]. The tendon falls into three broad forms: tendinitis/tendinosis plus tenosynovitis, tendon subluxation/dislocation, and tendon splits/tears [9]. Anti-inflammatory drugs, rest, or activity modification are typically prescribed; elsewhere orthoses with typical lateral wedging orthoses (TLWO) or lateral forefoot posting have been proposed to solve slight or mild cases [10,11], tilting the hindfoot to the valgus position to diminish the strain of the lateral tissues of the ankle. However, while the effects of typical supination orthoses on peroneus longus or tibial anterior muscular behaviour have been assessed in some EMG studies [12,13], the EMG of lateral pronation orthoses on PL activity remains unclear, especially during running; in addition, no studies have investigated the effects of innovative medial cushioned orthoses (IMCO) without any lateral enhancement material combined with a medial soft stuffed material on the EMG activity cost of PL muscle during running activity.
Therefore, the purpose of the present study was to investigate the EMG changes of PL activity during running wearing two kinds of orthoses: TLWO of 3, 6, and 9 mm versus IMCO of 3, 6, and 9 mm, relative to neutral running shoes (NRS) without orthoses. We hypothesized that IMCO could decrease the muscular activity of PL more than TLWO or NRS during the full running gait cycle.

2. Materials and Methods

The present study was reviewed and approved by the review board at Nuestra Señora de Valme Hospital (certificate number 2115 N20). Ethical and Human guides have been followed according to the Declaration of Helsinki; all participants signed informed consent before starting the study.

2.1. Study Design and Sample Size

The appropriate sample size needed for the present study was calculated by the statistics unit of Universidad Complutense de Madrid, Spain. The aim was to compare the EMG changes of PL muscle activity between TLWO of 3, 6, and 9 mm versus IMCO of 3, 6, and 9 mm relative to NRS during running. In previous studies of gastrocnemius lateralis EMG activity during running, a value of 25.96 ± 4.68 millivolts (mV) wearing novel orthoses has been reported (compared to 22.27 ± 2.51 mV wearing classic shoes) (p < 0.05). Considering a statistical power of 80%, a 95% confidence interval (CI), β = 20%, and α = 0.05, it was estimated that 31 subjects would be needed in this study. The Observational Studies in Epidemiology (STROBE) [3] criteria and randomly consecutive sampling techniques were followed throughout this study.

2.2. Participants

The following inclusion criteria were followed to select the participants: (1) healthy women and men people ranging between 18 and 30 years old; (2) recreational rearfoot strike pattern-runners that perform 3 days per week training sessions with at least 1 year of experience; and (3) neutral foot posture index (FPI) [14]. The exclusion criteria were (1) to have any pain or any lower limb injury at the time of the test or 1 year ago; (2) to be in treatment with any medication; and (3) to have any restrictive joint mobility on feet or lower limb far from valid values [15,16]. Body max index (BMI) = weight (kg)/height (m2) was calculated, avoiding hypothetical bias on data recollection or interpreting.

2.3. Instruments and Assessments

A NeuroTrac Simplex Plus (Verity Medical Ltd., Braishfield, UK) EMG electronic device with a USB-Bluetooth was used to study the superficial EMG contraction [17,18] of PL muscle fibres during running trials; 0.2 mV to 2000 mV was the range of record of the device, with a sensitivity of 0.1 mV root mean square (RMS), 10 m of free wireless (via Bluetooth) connection range, and an accuracy of 4% of the reading from mV ± 0.3 mV to 200 Hz with a bandpass filter of 18 Hz ± 4 Hz to 370 Hz ± 10% for readings below 235 mV.
The signal was detected with self-adhesive circular surface electrodes made on high-quality hydrogel with conductive carbon film and 30 mm dia-round size; the information was sent under a unidirectional radioelectric secure connection to the receiver module and filtered automatically by the NeuroTrac software (Verity Medical Ltd., Braishfield, UK). After that, the computer digitally transformed it by the software to generate the activity pattern values of each electrode.

2.4. Materials

IMCO was made with a flat sheet of 3 mm density and high hardness of ethylene-vinyl acetate (EVA) and with a medial cushioning casting placed from the bisectrix of the rear part of the orthotic to its medial edge, filled with viscoelastic rubber of Poron (Microban) [19]. Covering the superficial layer of the orthotic, 1 mm thickness of low hardness EVA was used (Figure 1 and Figure 2). A flat sheet of 6 and 9 mm with the same design and materials were made to complete the IMCO.
The TLWO was made with a flat sheet of 1 mm of ethylene-vinyl acetate (EVA) thickness of high hardness with a posting wedge of 3 mm EVA thickness, placed on the lateral rear of the orthotic (Figure 3 and Figure 4). Other 6 and 9 mm lateral wedge postings were made to complete the TLWO.
To avoid any influence on the normal foot biomechanics behavior, no more orthotic elements were added in the inserts; both left and right IMCO and TLWO orthoses were manufactured. The laboratory producer of these orthoses was an external company and was blinded during all stages of the study. The NRS used were “New Feel PW 100 M medium grey” (ref. number: 2018022).

2.5. Procedure

An experienced podiatric clinician and researcher (Rubén Sánchez-Gómez) took the measurements of the participants. To set the proper location of the sensors on PL muscular belly, the researcher had to request each participant to do foot eversion against clinician resistance for a few seconds; then, self-sticking surface electrodes were placed on the skin area where the most prominent bulge of the PL muscle was located, according to European recommendations for surface EMG [20]. Next, maximal eversion movement against the clinician’s hand resistance was done again for 5 s to set the maximal voluntary contraction needed to calibrate the device and normalise each trial’s EMG data amplitudes.

Running Test

An automatic motorized treadmill (Domyos T520) was used to perform the running test. Subjects were requested to run once for 3 min at 5.7 km/h on the treadmill wearing NRS to become acclimatized [21] and reduce the hypothetical bias of “new use-materials”. Then, the running test was performed at 9 km/h [22] under seven conditions (NRS, IMCO 3 mm, IMCO 6 mm, IMCO 9 mm, TLWO 3 mm, TLWO 6 mm, and TLWO 9 mm) randomly performed on the same day. The mean of the EMG PL muscle activity of the right leg was recorded for 30 s, three times (a total of 21 trials per participant), leaving 5 min for rest between each test [23]. To avoid a possible imbalance of the musculoskeletal system, the same orthotic conditions for each trial were placed on the left foot.

2.6. Statistical Analysis

Demographic variables were shown as means and standard deviations. The within-day trial-to-trial intraclass correlation coefficient (ICC) and standard error of measurement (SEM) were calculated [24] for all subjects under seven conditions to assess the reliability of the present research. According to Landis and Koch [25] estimations, the ICCs would be slight if it showed < 0.20; fair if 0.20–0.40; moderate if 0.41–0.60; substantial if 0.61–0.80; and almost perfect agreement if 0.81–1.00. In the present research, we considered ICCs of ≥0.81 to get the optimal scientific validity to support the results. The SEM was calculated to find the minimum detectable change (MDC) for all measurements. The normality of the sample was calculated using the Shapiro–Wilks test, considering normal distribution if p > 0.05.
To check the presence of the difference between conditions, a non-parametric Friedman test was used. To analyse these differences, the Wilcoxon test with Bonferroni correction was performed. Statistically significant differences were indicated when p < 0.05, with 95% CI.

3. Results

All present study participants were recruited from a podiatry clinic in Madrid (Spain) over 90 days (November 2020 to January 2021). Fifty-six subjects were asked to participate in the experiment and assessed for eligibility; twenty participants did not meet the requirements of inclusion criteria, and five were lost participants; ultimately, 31 participants (14 males and 17 females) were enrolled in the study; sociodemographic data are shown in Table 1.
The Shapiro–Wilks test showed a no-normal distribution of the sample (p < 0.05) and Friedman test showed that the values were different between the conditions (p < 0.05).
The reliability of the EMG muscle data during the full running activity cycle for the seven different conditions is shown as the ICC and SEM in Table 2. All recollected data were higher than the established 0.81, which suggest that values had “almost perfect reliability” [25]. The TLWO 9 mm reached the highest value with 0.993, and the IMCO 3 mm the lowest with 0.990. Regarding SEM, the IMCO 9 mm achieved the lowest value (0.372) and the TLWO 3 mm the highest (0.463). The MDC data showed the lowest value for the IMCO 9 mm (1.03) and the TLWO 3 mm was the highest (1.284). All MDC values were lower than the mean differences found between NRS, TLWO, and IMCO, and therefore, the data reach the optimal quality to be considered.
PL muscle EMG mean activities while running with NRS were compared to TLWO 3 mm, 6 mm, 9 mm and with IMCO 3 mm, 6 mm, and 9 mm (Table 3, with their p-values in Table 4).
All EMG values of TLWO and IMCO showed statistically significant reductions in respect to NRS; in detail, from NRS 23.08 ± 6.67 to TLWO 3 mm 18.23 ± 4.16 (p < 0.001), to TLWO 6 mm 17.9 ± 3.78 (p < 0.001) and to TLWO 9 mm 17.77 ± 4.794 (p < 0.001); from NRS 23.08 ± 6.67 to IMCO 3 mm 18.64 ± 4.40 (p < 0.001), to IMCO 6 mm 18.26 ± 4.26 (p < 0.001) and to IMCO 9 mm 18.13. ± 3.86 (p < 0.001). Concerning the comparisons between pair-to-pair, the TLWO/IMCO data also showed some statistically significant values, specifically for IMCO 3 mm (18.64 ± 4.40) versus IMCO 6 mm (18.26 ± 4.26) (p < 0.05) and IMCO 3 mm (18.64 ± 4.40) versus IMCO 9 mm (18.13 ± 3.86) (p < 0.05).

4. Discussion

In the present study, we aimed to determine the EMG activity reaction of the PL wearing NRS compared with IMCO and TLWO.
The use of lateral load deviations to treat peroneal disorders associated with rearfoot varus deformities are justified in multiple studies; in some cases, authors use lateral wedges to increase the lateral moments of the ankle [11,26,27] and/or subtalar joint [28] to alleviate medial knee osteoarthritis syndromes; in other cases, surgery procedures [29,30] are indicated to reduce varus hindfoot deformities to improve the strain of the PL and/or brevis and even to support the hyperlaxity of the rearfoot complex. Closer to our study, orthoses devices together with taping have been proposed [4] as an intervention to prevent ankle sprains; postural sway of acute ankle-supinated injuries has shown improvement wearing orthoses and they offered protection against reinjury, enhancing the ankle mechanoreceptors [31,32]; however, the effects that support the control inversion perturbations of ankle prevention and/or during/post-injury were not clear [5].
According to our results, the decreases in the EMG of the PL signal when wearing either TLWO (p < 0.001) or IMCO (p < 0.001)—regardless of their thickness—verify that these orthoses with pronator elements could be a conservative option to relax over-supination injuries that affect the tired or strained PL [8]. This follows the subtalar axis rotation equilibrium theory that argued the use of external forces on the lateral side of that axis to increase the pronated moments on the rearfoot [33] and similarly in line with the results of Moisan et al. [34,35], who assessed the PL muscle activity on subjects with cavus foot during walking with orthoses with lateral bar similar to our TLWO and obtaining similar discharged effects on PL muscle EMG amplitudes.
Based on available research, we can say that there is a lack of references to compare the decrease of PL EMG activity when wearing some orthotic device during running; Konradsen et al. [2] concluded that an external ankle support could decrease the EMG of PL during running. Another study referred that the EMG of PL in pronated or valgus feet were decreased during walking [36] or running [37], postulating the general concept of pronation and the decrease of PL muscular activity. The study of Baur et al. [10] compared PL activity with and without wearing detorsion wedge forefoot on semirigid orthoses of polyurethane during running, in patients with ankle instability; the authors did not find any differences between groups, only a higher pre-activation of PL EMG activity versus the group of no-orthoses was recorded; these results contrast with ours, but these researchers used a forefoot element whereas the key of the peroneal control is in the rearfoot; moreover, they studied the EMG of the PL wearing full-shape-conformed orthoses, including the longitudinal medial arch, which could itself influence the muscular activity of the PL due to its passing through the plantar foot, whereas present research made flat-shaped non-conformed orthoses with only a rearfoot effect, to avoid this plausible slant.
Regarding comparisons between IMCO vs. TLWO, we found that the alleviating effects on muscular PL activity were essentially the same compared with NRS with the advantage that IMCO density and size were less than TLWO, which supposes a wishing condition to running economy, according to Ray et al. [38]. The soft material embedded in the medial side of the IMCO decreased PL activity, as occurred when wearing similar soft material on cushioning running shoes in other references [39,40] during a running-EMG test.

Limitations

The assessed muscular activity of the PL results must be interpreted with caution because the EMG device used in the present study has high sensitivity, and the maximal voluntary isometric contraction test used to calibrate the signal device can vary between participants.
Due to the deep location of the peroneus brevis muscular belly and the difficulty in reaching its muscular activity with the superficial EMG device used in the present study, the authors decided to rule out the assessment of this muscle.
The present results are not specifics to any phase of running gait, but to a mean value of a whole running gait cycle.

5. Conclusions

Foot orthoses with rearfoot lateral corrections to control the supination of the hindfoot have been a classical tool to treat ankle instability, but there has been a lack of studies addressing PL muscular activity wearing these orthoses during running. The present research has shown that wearing either IMCO or TLWO versus NRS decreases the EMG activity of the PL during a full running gait cycle in healthy subjects, with the advantage that IMCO offers less thickness and volume to users and hence a better running economy. Therefore, the prescription of foot orthoses with pronator elements on the rearfoot can be considered to treat pathologies involving PL overloads. To our knowledge, this is the first study to show the EMG effects of TLWO on PL activity, thereby enhancing the knowledge about the use of these kinds of orthopaedic corrections of the rearfoot, away from the unique balance of the rearfoot varus position.

Author Contributions

Conceptualization, R.S.-G. and B.d.l.C.-T.; methodology, C.M.-S. and L.A.; software, A.G.-C.; validation, B.d.l.C.-T.; formal analysis, D.S.; investigation, L.A., P.S.-W.; resources, R.S.-G.; data curation, A.N.-F., P.S.-W. and C.M.-S.; writing—original draft preparation, R.S.-G., A.G.-C.; writing—review and editing, D.S. and B.d.l.C.-T.; visualization, A.N.-F.; supervision, B.d.l.C.-T. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The present study was reviewed and approved by the review board at the Hospital Nuestra Señora de Valme (certificate number 2115N20). Ethical and Human guidelines have been followed according to the Declaration of Helsinki.

Informed Consent Statement

All participants signed an informed consent before the start of the study.

Data Availability Statement

All data supporting reported results can be request at R.S.-G. and the data will be provided.

Conflicts of Interest

The authors declare no conflict of interest. Authors do not have any personal circumstances or interest that may be perceived as inappropriately influencing the representation or interpretation of reported research results. There are no funders in the present research.

References

  1. Gribble, P.A.; Bleakley, C.M.; Caulfield, B.M.; Docherty, C.L.; Fourchet, F.; Fong, D.T.; Hertel, J.; Hiller, C.E.; Kaminski, T.W.; McKeon, P.O.; et al. Evidence review for the 2016 International Ankle Consortium consensus statement on the prevalence, impact and long-term consequences of lateral ankle sprains. Br. J. Sports Med. 2016, 50, 1496–1505. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Konradsen, L.; Voigt, M.; Højsgaard, C. Ankle inversion injuries. The role of the dynamic defense mechanism. Am. J. Sports Med. 1997, 25, 54–58. [Google Scholar] [CrossRef] [PubMed]
  3. McKeon, P.O.; Donovan, L. A Perceptual Framework for Conservative Treatment and Rehabilitation of Ankle Sprains: An Evidence-Based Paradigm Shift. J. Athl. Train. 2019, 54, 628–638. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Doherty, C.; Bleakley, C.; Delahunt, E.; Holden, S. Treatment and prevention of acute and recurrent ankle sprain: An overview of systematic reviews with meta-analysis. Br. J. Sports Med. 2017, 51, 113–125. [Google Scholar] [CrossRef]
  5. Kaminski, T.W.; Hertel, J.; Amendola, N.; Docherty, C.L.; Dolan, M.G.; Hopkins, J.T.; Nussbaum, E.; Poppy, W.; Richie, D.; National Athletic Trainers’ Association. National Athletic Trainers’ Association position statement: Conservative management and prevention of ankle sprains in athletes. J. Athl. Train. 2013, 48, 528–545. [Google Scholar] [CrossRef] [Green Version]
  6. Kaminski, T.W.; Needle, A.R.; Delahunt, E. Prevention of Lateral Ankle Sprains. J. Athl. Train. 2019, 54, 650–661. [Google Scholar] [CrossRef] [Green Version]
  7. Roster, B.; Michelier, P.; Giza, E. Peroneal Tendon Disorders. Clin. Sports Med. 2015, 34, 625–641. [Google Scholar] [CrossRef]
  8. Koldenhoven, R.M.; Feger, M.A.; Fraser, J.J.; Saliba, S.; Hertel, J. Surface electromyography and plantar pressure during walking in young adults with chronic ankle instability. Knee Surg. Sports Traumatol. Arthrosc. Off. J. ESSKA 2016, 24, 1060–1070. [Google Scholar] [CrossRef]
  9. Maffulli, N.; Khan, K.M.; Puddu, G. Overuse tendon conditions: Time to change a confusing terminology. Arthrosc. J. Arthrosc. Relat. Surg. 1998, 14, 840–843. [Google Scholar] [CrossRef]
  10. Baur, H.; Hirschmüller, A.; Müller, S.; Mayer, F. Neuromuscular activity of the peroneal muscle after foot orthoses therapy in runners. Med. Sci. Sports Exerc. 2011, 43, 1500–1506. [Google Scholar] [CrossRef]
  11. Lugo-Pico, J.G.; Kaiser, J.T.; Sanchez, R.A.; Aiyer, A.A. Peroneal Tendinosis and Subluxation. Clin. Sports Med. 2020, 39, 845–858. [Google Scholar] [CrossRef] [PubMed]
  12. Murley, G.S.; Bird, A.R. The effect of three levels of foot orthotic wedging on the surface electromyographic activity of selected lower limb muscles during gait. Clin. Biomech. 2006, 21, 1074–1080. [Google Scholar] [CrossRef] [PubMed]
  13. Murley, G.S.; Landorf, K.B.; Menz, H.B.; Bird, A.R. Effect of foot posture, foot orthoses and footwear on lower limb muscle activity during walking and running: A systematic review. Gait Posture 2009, 29, 172–187. [Google Scholar] [CrossRef] [PubMed]
  14. Redmond, A.C.; Crosbie, J.; Ouvrier, R.A. Development and validation of a novel rating system for scoring standing foot posture: The Foot Posture Index. Clin. Biomech. 2006, 21, 89–98. [Google Scholar] [CrossRef]
  15. Root, M.L.; Orien, W.P. Normal and Abnormal Function of the Foot; Clinical Biomechanics Corp, Ed.; Clinical Biomechanics Corp.: Los Angeles, CA, USA, 1977; Volume II. [Google Scholar]
  16. Sánchez-Gómez, R.; Becerro-de-Bengoa-Vallejo, R.; Losa-Iglesias, M.E.; Calvo-Lobo, C.; Navarro-Flores, E.; Palomo-López, P.; Romero-Morales, C.; López-López, D. Reliability Study of Diagnostic Tests for Functional Hallux Limitus. Foot Ankle Int. 2020, 41, 457–462. [Google Scholar] [CrossRef] [PubMed]
  17. Sánchez-Gómez, R.; Becerro-de-Bengoa-Vallejo, R.; Romero Morales, C.; Losa-Iglesias, M.E.; Castrillo de la Fuente, A.; López-López, D.; Vega, I.D.; Calvo-Lobo, C. Muscle Activity of the Triceps Surae With Novel Propulsion Heel-Lift Orthotics in Recreational Runners. Orthop. J. Sports Med. 2020, 8, 2325967120956914. [Google Scholar] [CrossRef] [PubMed]
  18. Sánchez-Gómez, R.; Romero-Morales, C.; Gómez-Carrión, Á.; De-La-cruz-torres, B.; Zaragoza-García, I.; Anttila, P.; Kantola, M.; Ortuño-Soriano, I. Effects of novel inverted rocker orthoses for first metatarsophalangeal joint on gastrocnemius muscle electromyographic activity during running: A cross-sectional pilot study. Sensors 2020, 20, 3205. [Google Scholar] [CrossRef]
  19. Tong, J.W.K.; Ng, E.Y.K. Preliminary investigation on the reduction of plantar loading pressure with different insole materials (SRP—Slow Recovery Poron®, P—Poron®, PPF—Poron®+Plastazote, firm and PPS—Poron®+Plastazote, soft). Foot 2010, 20, 1–6. [Google Scholar] [CrossRef]
  20. Hermens, H.J.; Freriks, B.; Disselhorst-Klug, C.; Rau, G. Development of recommendations for SEMG sensors and sensor placement procedures. J. Electromyogr. Kinesiol. 2000, 10, 361–374. [Google Scholar] [CrossRef]
  21. Roca-Dols, A.; Elena Losa-Iglesias, M.; Sánchez-Gómez, R.; Becerro-de-Bengoa-Vallejo, R.; López-López, D.; Palomo-López, P.; Rodríguez-Sanz, D.; Calvo-Lobo, C. Electromyography activity of triceps surae and tibialis anterior muscles related to various sports shoes. J. Mech. Behav. Biomed. Mater. 2018, 86, 158–171. [Google Scholar] [CrossRef]
  22. Shih, Y.; Lin, K.-L.; Shiang, T.-Y. Is the foot striking pattern more important than barefoot or shod conditions in running? Gait Posture 2013, 38, 490–494. [Google Scholar] [CrossRef] [PubMed]
  23. Fleming, N.; Walters, J.; Grounds, J.; Fife, L.; Finch, A. Acute response to barefoot running in habitually shod males. Hum. Mov. Sci. 2015, 42, 27–37. [Google Scholar] [CrossRef] [PubMed]
  24. Saunders, P.U.; Pyne, D.B.; Telford, R.D.; Hawley, J.A. Reliability and variability of running economy in elite distance runners. Med. Sci. Sports Exerc. 2004, 36, 1972–1976. [Google Scholar] [CrossRef] [PubMed]
  25. Landis, J.R.; Koch, G.G. The measurement of observer agreement for categorical data. Biometrics 1977, 33, 159–174. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  26. Chapman, G.J.; Parkes, M.J.; Forsythe, L.; Felson, D.T.; Jones, R.K. Ankle motion influences the external knee adduction moment and may predict who will respond to lateral wedge insoles?: An ancillary analysis from the SILK trial. Osteoarthr. Cartil. 2015, 23, 1316–1322. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  27. Jones, R.K.; Chapman, G.J.; Forsythe, L.; Parkes, M.J.; Felson, D.T. The relationship between reductions in knee loading and immediate pain response whilst wearing lateral wedged insoles in knee osteoarthritis. J. Orthop. Res. 2014, 32, 1147–1154. [Google Scholar] [CrossRef] [Green Version]
  28. Kakihana, W.; Torii, S.; Akai, M.; Nakazawa, K.; Fukano, M.; Naito, K. Effect of a lateral wedge on joint moments during gait in subjects with recurrent ankle sprain. Am. J. Phys. Med. Rehabil. 2005, 84, 858–864. [Google Scholar] [CrossRef]
  29. Davda, K.; Malhotra, K.; O’Donnell, P.; Singh, D.; Cullen, N. Peroneal tendon disorders. EFORT Open Rev. 2017, 2, 281–292. [Google Scholar] [CrossRef]
  30. Heckman, D.S.; Reddy, S.; Pedowitz, D.; Wapner, K.L.; Parekh, S.G. Operative treatment for peroneal tendon disorders. J. Bone Jt. Surg. Am. Vol. 2008, 90, 404–418. [Google Scholar] [CrossRef] [PubMed]
  31. Guskiewicz, K.M.; Perrin, D.H. Effect of orthotics on postural sway following inversion ankle sprain. J. Orthop. Sports Phys. Ther. 1996, 23, 326–331. [Google Scholar] [CrossRef] [Green Version]
  32. Ludwig, O.; Kelm, J.; Fröhlich, M. The influence of insoles with a peroneal pressure point on the electromyographic activity of tibialis anterior and peroneus longus during gait. J. Foot Ankle Res. 2016, 9, 33. [Google Scholar] [CrossRef] [Green Version]
  33. Kirby, K.A. Subtalar joint axis location and rotational equilibrium theory of foot function. J. Am. Podiatr. Med. Assoc. 2001, 91, 465–487. [Google Scholar] [CrossRef] [PubMed]
  34. Moisan, G.; Cantin, V. Effects of two types of foot orthoses on lower limb muscle activity before and after a one-month period of wear. Gait Posture 2016, 46, 75–80. [Google Scholar] [CrossRef] [PubMed]
  35. Moisan, G.; Descarreaux, M.; Cantin, V. Biomechanical effects of foot orthoses with and without a lateral bar in individuals with cavus feet during comfortable and fast walking. PLoS ONE 2021, 16, e0248658. [Google Scholar] [CrossRef]
  36. Hunt, A.E.; Smith, R.M. Mechanics and control of the flat versus normal foot during the stance phase of walking. Clin. Biomech. 2004, 19, 391–397. [Google Scholar] [CrossRef] [PubMed]
  37. Mündermann, A.; Wakeling, J.M.; Nigg, B.M.; Humble, R.N.; Stefanyshyn, D.J. Foot orthoses affect frequency components of muscle activity in the lower extremity. Gait Posture 2006, 23, 295–302. [Google Scholar] [CrossRef]
  38. Ray, S.F.; Takahashi, K.Z. The influence of footwear on the electromyographic activity of selected lower limb muscles. Sci. Rep. 2020, 10, 8793. [Google Scholar] [CrossRef]
  39. Scott, L.A.; Murley, G.S.; Wickham, J.B. The influence of footwear on the electromyographic activity of selected lower limb muscles during walking. J. Electromyogr. Kinesiol. 2012, 22, 1010–1016. [Google Scholar] [CrossRef]
  40. Roca-Dols, A.; Losa-Iglesias, M.E.; Sánchez-Gómez, R.; López-López, D.; Becerro-de-Bengoa-Vallejo, R.; Calvo-Lobo, C. Electromyography comparison of the effects of various footwear in the activity patterns of the peroneus longus and brevis muscles. J. Mech. Behav. Biomed. Mater. 2018, 82, 126–132. [Google Scholar] [CrossRef]
Figure 1. Innovative medial cushioned orthoses (IMCO) with medial cushioning casting filled with Poron (Microban).
Figure 1. Innovative medial cushioned orthoses (IMCO) with medial cushioning casting filled with Poron (Microban).
Jcm 11 01339 g001
Figure 2. Detail of medial cushioning casting filled with Poron (orange material) set on rear-medial side of a left innovative medial cushioned orthotic (IMCO).
Figure 2. Detail of medial cushioning casting filled with Poron (orange material) set on rear-medial side of a left innovative medial cushioned orthotic (IMCO).
Jcm 11 01339 g002
Figure 3. Typical lateral wedging orthoses (TLWO) with lateral enhancement of EVA on the rear side.
Figure 3. Typical lateral wedging orthoses (TLWO) with lateral enhancement of EVA on the rear side.
Jcm 11 01339 g003
Figure 4. Detail of the enhancement of EVA set on rear-lateral side of a left typical lateral wedging orthotic (TLWO).
Figure 4. Detail of the enhancement of EVA set on rear-lateral side of a left typical lateral wedging orthotic (TLWO).
Jcm 11 01339 g004
Table 1. Subject demographics.
Table 1. Subject demographics.
Variablen = 31
mean ± SD (95% CI)
Age (years)34.5 ± 3.33
(33.32–35.67)
FPI (scores)3.71 ± 0.19
(2.01–3.01)
Weight (kg)62.6 ± 8.68
(59.54–65.65)
Height (cm)162.25 ± 3.21
(161.11–163.38)
BMI (kg/m2)21.38 ± 3.02
(20.31–22.44)
Abbreviations: SD = standard deviation; CI = confidence interval; FPI = foot posture index; BMI = body mass index.
Table 2. Reliability ICC of variables with “Neutral Running Shoes” versus “Typical Lateral Wedging Orthoses” (TLWO) and “Innovative Medial Cushioned Orthoses” (IMCO) of 3, 6 and 9 mm.
Table 2. Reliability ICC of variables with “Neutral Running Shoes” versus “Typical Lateral Wedging Orthoses” (TLWO) and “Innovative Medial Cushioned Orthoses” (IMCO) of 3, 6 and 9 mm.
VariableNRSTLWO 3 mmTLWO 6 mmTLWO 9 mm
ICC (95% CI)SEMMDCICC (95% CI)SEMMDCICC (95% CI)SEMMDCICC (95%CI)SEMMDC
Peroneus Longus (mV)0.995
(0.992–0.998)
0.4551.2620.988
(0.978–0.994)
0.4631.2840.988
(0.978–0.994)
0.4191.1620.993
(0.987–0.996)
0.41.126
Peroneus Longus (mV)0.995
(0.992–0.998)
0.4551.2620.990
(0.981–0.995)
0.4511.2510.992
(0.985–0.996)
0.3821.060.991
(0.984–0.995)
0.3721.03
Abbreviations: ICC = intraclass correlation coefficient; CI = confidence interval; SEM = standard error of measurement; MDC = minimal detectable change; (mV) = millivolts; SO = shoe only; mm = millimeters.
Table 3. EMG signal amplitudes of the mean peroneus longus muscle activities between different study situations.
Table 3. EMG signal amplitudes of the mean peroneus longus muscle activities between different study situations.
NRSTLWO 3 mmTLWO 6 mmTLWO 9 mm
Variablemean (mV)Mean (mV)mean (mV)mean (mV)
± SD (95% CI)± SD (95% CI)± SD (95% CI)± SD (95% CI)
23.08 ± 6.6718.23 ± 4.1617.9 ± 3.7817.77 ± 4.794
Peroneus Longus(20.63–25.53)(16.7–19.76)(16.59–19.37)(16.01–19.52)
NRSIMCO 3 mmIMCO 6 mmIMCO 9 mm
Variablemean (mV)Mean (mV)mean (mV)mean (mV)
± SD (95% CI)± SD (95% CI)± SD (95% CI)± SD (95% CI)
23.08 ± 6.6718.64 ± 4.4018.26 ± 4.2618.13 ± 3.86
Peroneus Longus(20.63–25.53)(17.027–20.25)(16.7–19.83)(16.71–19.55)
Abbreviations: mV = millivolts; NRS = neutral running shoes; TLWO = typical lateral wedging orthoses; IMCO = innovative medial cushioned orthoses; mm = millimeters; ±SD = standard deviation
Table 4. p-Values comparison of the mean peroneus longus muscle activities between different study situations.
Table 4. p-Values comparison of the mean peroneus longus muscle activities between different study situations.
p-Value NRSp-Value NRSp-Value NRSp-Value TLWO 3 mmp-Value TLWO 3 mmp-Value
TLWO 6 mm
p-Value TLWO 3 mm
vs.
IMCO 3 mm
p-Value TLWO 6 mm
vs.
IMCO 6 mm
p-Value TLWO 9 mm
vs.
IMCO 9 mm
vs.vs.vs.vs.vs.vs.
TLWO 3 mmTLWO 6 mmTLWO 9 mmTLWO 6 mmTLWO 9 mmTLWO 9 mm
<0.001 **<0.001 **<0.001 **0.5180.1890.531
p-Value NRSp-Value NRSp-Value NRSp-Value IMCO 3 mmp-Value IMCO 3 mmp-Value
IMCO 6 mm
vs.vs.vs.vs.vs.vs.
IMCO 3 mmIMCO 6 mmIMCO 9 mmIMCO 6 mmIMCO 9 mmIMCO
9 mm
<0.001 **<0.001 **<0.001 **<0.05 *<0.05 *0.6660.1420.3830.131
Abbreviations: mV = millivolts; NRS = neutral running shoes; TLWO = typical lateral wedging orthoses; IMCO = innovative medial cushioned orthoses; mm = millimeters; ±SD = standard deviation; p < 0.05 * (95% CI) was considered statistically significant; p < 0.001 ** (95% CI) was considered statistically significant.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Sanchez-Gomez, R.; Gomez-Carrion, A.; Martinez-Sebastian, C.; Alou, L.; Sevillano, D.; Nuñez-Fernandez, A.; Sanz-Wozniak, P.; de la Cruz-Torres, B. Innovative Medial Cushioning Orthoses Affect Peroneus Longus Electromyographic Activity during Running. J. Clin. Med. 2022, 11, 1339. https://doi.org/10.3390/jcm11051339

AMA Style

Sanchez-Gomez R, Gomez-Carrion A, Martinez-Sebastian C, Alou L, Sevillano D, Nuñez-Fernandez A, Sanz-Wozniak P, de la Cruz-Torres B. Innovative Medial Cushioning Orthoses Affect Peroneus Longus Electromyographic Activity during Running. Journal of Clinical Medicine. 2022; 11(5):1339. https://doi.org/10.3390/jcm11051339

Chicago/Turabian Style

Sanchez-Gomez, Ruben, Alvaro Gomez-Carrion, Carlos Martinez-Sebastian, Luis Alou, David Sevillano, Almudena Nuñez-Fernandez, Paola Sanz-Wozniak, and Blanca de la Cruz-Torres. 2022. "Innovative Medial Cushioning Orthoses Affect Peroneus Longus Electromyographic Activity during Running" Journal of Clinical Medicine 11, no. 5: 1339. https://doi.org/10.3390/jcm11051339

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop