Effect of Ion Selectivity on Current Production in Sewage Microbial Fuel Cell Separators

1
Department of Civil Engineering, Nagoya Institute of Technology (Nitech), Nagoya 466-8555, Japan
2
Graduate School of Sciences and Technology for Innovation, Yamaguchi University, Yoshida, Yamaguchi 753-8511, Japan
*
Author to whom correspondence should be addressed.
These authors contributed equally to this study.
Membranes 2022, 12(2), 183; https://doi.org/10.3390/membranes12020183
Submission received: 30 November 2021 / Revised: 28 January 2022 / Accepted: 31 January 2022 / Published: 3 February 2022
(This article belongs to the Special Issue Membranes for Resource Recovery in Bioelectrochemical Systems)

Abstract

:
This study compared the performance of two microbial fuel cells (MFCs) equipped with separators of anion or cation exchange membranes (AEMs or CEMs) for sewage wastewater treatment. Under chemostat feeding of sewage wastewater (hydraulic retention time of approximately 7 h and polarization via an external resistance of 1 Ω), the MFCs with AEM (MFCAEM) generated a maximum current that was 4–5 times greater than that generated by the MFC with CEM (MFCCEM). The high current in the MFCAEM was attributed to the approximately neutral pH of its cathode, in contrast to the extremely high pH of the MFCCEM cathode. Due to the elimination of the pH imbalance, the cathode resistance for the MFCAEM (13–19 Ω·m2) was lower than that for the MFCCEM (41–44 Ω·m2). The membrane resistance measured as the Cl mobility of AEMs for the MFCAEM operated for 35, 583, and 768 days showed an increase with operation time and depth, and this increase contributed minimally to the cathode resistance of the MFCAEM. These results indicate the advantage of the AEM over the CEM for air-cathode MFCs. The membrane resistance may increase when the AEM is applied in large-scale MFCs on a meter scale for extended periods.

1. Introduction

Wastewater treatment is becoming extremely important in present times. It is crucial not only in conserving public water quality but also in supplying sufficient quantities of safe water to address rapidly increasing demands [1]. Water treatment technology is widely used. However, electricity consumption in sewage treatment accounts for 0.7–4% of domestic electricity consumption in developed countries [2,3], and a substantial amount of greenhouse gases are emitted. To ensure sustainable water cycles, the wastewater treatment should maximize energy conservation by recovering the biomass energy contained in wastewater [4]. Typically, most of the energy recovered is obtained from converting sludge biomass into biogas [4] via microbial fermentation and solid fuel [5]. However, because of the low biomass concentration and substantial volume of wastewater, energy recovery from wastewater is still in the research stage. Several treatment methods that integrate energy recovery, such as microalgae cultivation, membrane-enriched fermentation, and microbial fuel cells (MFCs) [6], have been evaluated in the past. Among these, MFCs received the most attention for treating wastewater with simultaneous recovery of electricity [7].
MFCs generally comprise an anode, a cathode, and a separator. The anode collects electrons that are emitted by the microbial oxidization of organic matter in an anolyte, such as wastewater. The cathode reduces oxidants such as oxygen using electrons collected in the anode. The separator insulates the electrodes while maintaining the mobility of the ions or oxidants. Air-cathode MFCs are the most common type of MFCs and have a single anolyte chamber with cathodes exposed to the air. The catalysts for the anode reactions are microorganisms that degrade various organic matter, and the catalysts for cathode reactions are carbon particles that can reduce oxygen. Currently, the limited electric power production of the MFCs makes them impractical for application in real wastewater treatment. The performance of all three key components needs to be improved [8], particularly in terms of scaling-up. The challenges include developing (i) low-cost mass production technology for the anode, (ii) improved oxygen reducing catalyst for the cathode, and (iii) a resilient separator with high ion mobility. Among them, the selection of the separator significantly affects the performance of the MFC and the lifetime required to generate electric power.
The first air-cathode MFCs were equipped with proton-exchange [9] and later equipped with ion-exchange membranes (IEMs) because of cost effectiveness. Both membranes have been extensively used in hydrogen fuel cells [10] and iron-based flow-battery systems [11]. Non-ion-exchange membranes (NIEs) have been used as separators [12,13,14,15] in combination with polytetrafluoroethylene PTFE) gas diffusion layers (GDLs), which have oxygen mobility [16]. Examples of such membranes include glass fiber mats, polypropylene porous plastic plates, and non-woven fabrics. Compared to IEMs, systems with GDL and NIEs enable lower costs, although the cathode facing the liquid phase generally has a short lifetime due to biofouling on the cathode [17]. The MFCs with GDLs and NIEs exhibited a 34% decrease in electricity production after one month [13]; washing was required to recover the initial levels of performance [18,19] that was caused by aerobic bacterial growth on the cathode facing the wastewater. In contrast, the MFCs equipped with a cation exchange membrane (CEM) performed almost consistently over an entire year [20,21]. Recently, a scalable air-cathode MFCs equipped with an anion exchange membrane (AEM) was demonstrated for the first time [2], and electricity was successfully recovered from sewage wastewater over a year [22]. A comparison of electric power production by MFCs using AEMs and CEMs demonstrated the advantage of AEMs, which mitigate the pH imbalances that are often observed in MFCs with CEMs [23,24,25]. However, comparative studies are limited to milliliter scales in batch mode, making it difficult to evaluate the effects on the performance of MFCs in actual wastewater treatment.
In this study, the effect of the ion selectivity of IEMs on MFCs performance was evaluated in air-cathode MFCs equipped with AEMs and CEMs. These MFCs were operated in the chemostat in a sewage wastewater treatment plant, and the electric power density, chemical oxygen demand (COD) removal efficiency (COD-RE), membrane resistance, and cathode resistance were compared. In addition, the effect of operation time on the AEM resistance was evaluated to estimate the lifetime of the AEMs in the air cathode-MFC.

2. Materials and Methods

2.1. MFC Used in the Experiment

In this study, a cylindrical MFC core (Φ5 cm × 100 cm) with an air cathode [26] prepared from a stainless-steel mesh surrounded by a carbon-based cathode was used along with an IEMs and nonwoven graphite fabric (TOYOBO Co., Ltd., Osaka, Japan). The IEMs were either CEMs (CSE; Astom Co., Ltd., Tokyo, Japan) or AEMs (ASE; Astom Co., Ltd.). The thicknesses of the CEM and AEM were 0.16 and 0.15 mm, respectively. The membrane resistances were 0.18 and 0.26 Ω·m2, respectively, in 0.5 N NaCl at 25 °C according to the manufacturer’s catalogue. Carbon cloths painted with a mixture of activated carbon and carbon black were used as cathodes. Twelve carbon brushes (Φ4.0 cm × 100 cm) were placed around the MFC core, in addition to the nonwoven graphite fabric. The MFC units of the core and 12 additional carbon brushes were defined as the MFCAEM and MFCCEM equipped with an AEM and a CEM as separators, respectively. A mixture of poly (diallyldimethylammonium chloride) (PDDMAC) and PTFE [2] were used as the binders of the carbon catalyst pastes for the MFCAEM and a 7 L/mg-mixture of carbon in a 10% Nafion solution were used for the MFCCEM, respectively. Carbon brushes were manufactured using carbon fabrics (T300B-3k-40B, Toray, Tokyo, Japan), soaked in acetone, and heated at 450 °C for 5 h before use [27] to render the surface sufficiently hydrophilic for microbial adhesion [28].

2.2. Operation of the MFC Reactors

The MFCAEM and MFCCEM were installed in cylindrical reactors (Φ25 cm × 110 cm) made of polyvinyl chloride and filled with 50 L of wastewater. The reactor was operated in a sewage wastewater treatment plant (Nagoya City) and continuously supplied with influent using a tubing pump (TP-20SA, AS ONE, Osaka, Japan) with a hydraulic retention time (HRT) of 2.6–9.8 h. The HRTs were set by changing the inflow rate to realize different COD concentrations in the reactor. For the initial 35 days, the influent of the primary sedimentation tank (PST) was used; later the effluent of the PST was used due to the clogging of the tube by the influent. Wastewater in the reactor was circulated at a circulation time of 15 min using a submersible pump (LEDGLE, Shenzhen, China). The cathode and anode of the MFC were connected via an external resistor (Rext) of 1 Ω and a voltage data logger (VR-71; T&D Co., Nagano, Japan) parallel to Rext. The cell voltage between anode and cathode was recorded hourly.

2.3. Power Density Curve

Power density curves were measured for the MFCAEM and MFCCEM with HRTs of 3.0–9.8 h at 9, 18, and 30 days after the commencement of operation. As noted previously, the MFCs were connected in parallel with 1, 2, 5, 10, 20, 50, 100, and 10,000 Ω Rext [29]. An Ag/AgCl reference electrode (RE-1B; BAS Co., Ltd., Tokyo, Japan) was installed close to the MFC anode, and the anode and cathode potentials were measured. The anode (Ran) and cathode (Rca) resistances of the MFC were calculated by dividing the electrode potential difference by the current and multiplying it with the separator area [30].

2.4. COD Removal and Coulombic Efficiencies

COD was determined by adding potassium dichromate as an oxidizing agent and mercury as a reducing agent to the sample, followed by heating. Subsequently, the absorbance was measured with a spectrophotometer to determine the concentration [31]. The COD-RE [%] was calculated using Equation (1) with CODIN [mg/L] and CODEF [mg/L] values, that is, the concentrations of organic matter in the influent and effluent, respectively.
C O D - R E = C O D I N C O D E F C O D I N × 100 .
Coulombic efficiency (CE) is the ratio of charge recovered as current to the total charge obtained from the decomposition of organic matter in sewage. It can be expressed by Equation (2).
C E = C p C T i × 100 .
where Cp [C] is the cumulative charge carried by the current during the given HRT and CT [C] is the theoretical charge that is calculated using Equation (3).
C T = C O D · V F b M   .
where ΔC [g/L] is the difference between CODIN and CODEF, V [L] is the volume of wastewater in the reactor, F [C/mol] is Faraday constant (=96,485 C/mol), b is number of moles of electrons produced from 1 mol of oxygen (b = 4), and M [g/mol] is molecular weight of oxygen (M = 32). The CE was determined by least-squares fitting of the measured and calculated currents using the CE as a variable in Equation (2).

2.5. Measuring Membrane Resistance

The electrical resistance of the AEM before and after 35, 583, and 768 days of operation was measured using a custom-built acrylic cell, as described in a previous study [32]. The old AEMs (583 and 783 d) were taken from an air-cathode MFC [22] similar to the MFC used in this study. The AEMs were taken from the top, middle, and bottom of the cell, and cut into squares of approximately 5 cm × 5 cm (with an effective area of 11 cm2). Following this, the cell was filled with a 0.5 M NaCl solution. Two parallel Pt electrodes were placed on both sides of the AEM and connected to an LCR meter (AD-5827; A&D Co., Ltd., Tokyo, Japan). The membrane resistance (Rm) [Ω·cm2] was calculated using the values of resistance measured between the electrodes with and without membranes, denoted by R1 and R0, respectively, using the equation Rm = R1−R0. The resistances were measured using alternating current (AC) at a frequency of 10 kHz. It must also be noted that certain membranes were pre-incubated in 0.5 M NaCl.

2.6. Linear Sweep Voltammetry (LSV) Test

The effect of the AEM ages on the cathode reaction was evaluated by monitoring the current in a small cylindrical reactor (Φ6 cm × 5 cm) equipped with 0.5 mg/cm2 Pt-loaded carbon cloth [33] as the anode to avoid the restriction of the anode reaction, which is often observed in MFCs with low COD accessibility (Supplementary Figure S1). After operation for 35, 583, and 768 days, the cathodes and AEMs were set with the anode. The cathode and anode were used as the working electrode (WE) and counter electrode, respectively, and an Ag/AgCl reference electrode (012167RE-1B; BAS Co., Ltd., Tokyo, Japan) was placed near the anode. LSV measurements were performed using an electrochemical workstation (VMP-3; Bio-Logic, Claix, France) supplemented with hydrogen in the anolyte at approximately 0.1 MPa. The WE potential was set to 0.5 V and swept to −0.5 V vs. Ag/AgCl at 0.5 mV/s.

2.7. Investigation of Dirt on Membrane

White precipitates on 25 cm2 of the AEM (583 d) or CEM (35 d) were scrubbed and dissolved in 10 mL of 0.1 N HCl. The extracts were then filtered using a PTFE membrane filter (0.45 μm pore size) (Merck Millipore, Darmstadt, Germany). The filtrates were diluted 5–20 times and analyzed using an ion chromatography system (Shimadzu, Kyoto, Japan), including an electron conductivity detector (CDD-10Avp). Anions and cations in the samples were separated at 40 °C using Shim-pack IC-A3 (Φ4.6 × 150 mm) and Shim-pack IC-C4 (Φ4.6 × 150 mm), respectively. The mobile phase was a mixture of 8 mM p-hydroxybenzoic acid, 3.2 mM Bis-Tris, and 50 mM boric acid for anion analysis and a mixture of 2.5 mM oxalic acid dihydrate and 5 mM 18-Crown-6 for cation analysis.
The anode side of the AEM and CEM were observed by fluorescence microscopy after staining with SYBR Green II, a DNA-binding dye, as described in a previous study [34].

3. Results and Discussion

3.1. Current Production by the Two MFCs throughout the Operation

The MFCAEM and MFCCEM produced 0.80–1.30 A/m2 of current with the PST influent, although the operation was terminated due to the frequent clogging in the influent tube. The MFCAEM produced a current of 0.30–0.70 A/m2 with a continuous inflow of the PST effluent for 2.6–9.8 h of HRT. This current was approximately 4–5 times higher than that of MFCCEM, which produced 0.10–0.20 A/m2 (Figure 1). After 44 d, both MFCAEM and MFCCEM exhibited relatively stable currents, except for decreased currents in the MFCAEM reactor due to pumping problems. The slightly lower current observed from days 60 to 70 was probably caused by the supplementation of low COD because of the dilution of the inflow by rainwater. Assuming similar anode resistances in the MFCAEM and MFCCEM, the difference in current production can be attributed to the cathode reaction, which is typically regulated by the oxygen reduction rate of the cathode catalyst, oxygen availability, and ion mobility. The membrane resistance determined by ion mobility was smaller in CEM (0.16Ω·m2) than in AEM (0.26 Ω·m2) according to the manufacturer’s catalogue. Both MFCs had identical loaded cathode catalyst and oxygen availability. However, they had different binder components, that is, a mixture of PDDMAC and PTFE for MFCAEM, and Nafion for MFCCEM, which could potentially cause differences in oxygen availability to the carbon catalyst. Another factor was the difference in pH at the cathode. An approximate pH of 10–11 was measured on the cathode surface with CEM, in contrast to a neutral pH on that with AEM. This pH imbalance restricts electron transfer to oxygen, as suggested in a previous study [25]. Collectively, the differences in ion mobility, binder components, and pH resulted in higher current production in the MFCAEM.
The current density was similar to that generated by a similar MFC core without carbon brushes. The MFC without carbon brushes was also operated in the PST effluent with continuous inflow for 6 h of HRT using 2 Ω of the external resistance and recorded an average current density of 0.32 A/m2 [26]. The MFCAEM used in this study produced an average of 0.38 A/m2 for 6 h of HRT. This was unexpected because the increase in the anodic area caused by introducing the carbon brushes has been demonstrated in several studies [35,36]. The similarity in current production, despite the increase in the anodic area, was due to the reaction restriction of the cathode.

3.2. COD Removal and CE

The CODIN for the two MFCs was 210 ± 40 mg/L. MFC treatment at HRT = 7 h resulted in 66 ± 9.0 mg/L and 99 ± 51 mg/L of CODEF for the MFCAEM and MFCCEM, respectively (Table 1). The COD-REs of MFCAEM and MFCCEM were 69% ± 2.0% and 54% ± 19%, respectively, and were not significantly different (p > 0.05). The CEs of MFCAEM and MFCCEM were 1.6 ± 0.40% and 0.50 ± 0.35%, respectively. The superiority of MFCAEM in current recovery indicates the higher CE in MFCAEM than in MFCCEM.
The COD-RE achieved in the MFC indicated an improvement compared to that obtained with our previous MFCAEM, which exhibited 30% COD-RE at HRT = 6 h [26]; the COD-RE increased by approximately twice upon the introduction of carbon brushes. In addition, the CE was drastically reduced to less than 10% of that of the previous MFC without carbon brushes (23%) due to the reduction in specific cathode or separator areas with respect to wastewater volume; the introduction of 12 carbon brushes reduced the specific area from 14 m2/m3 [26] to 3.2 m2/m3 in this study. These results indicate the importance of determining the optimum ratio of carbon brushes to a specific cathode area [37]. However, the optimum ratio of carbon brushes to the MFCAEM is expected to vary at different CODs in the MFC reactor. This necessitates comprehensive MFC performance modeling that integrates COD as well as the anode and cathode surface areas.

3.3. Polarization Curve

Figure 2 shows the polarization curves for the MFCAEM and MFCCEM at HRTs in the range of 3.0–9.8 h. The open-circuit voltage (OCV) of the MFCAEM was the highest (0.43 V) for an HRT of 3.3 h and decreased to 0.37 and 0.39 V for an HRT of 6.9 and 9.8 h (Figure 2B, Table 1), respectively. The maximum power density (Pmax) showed a similar trend and was 0.064 W/m2 for an HRT of 3.3 h and decreased to 0.047 W/m2 and 0.032 W/m2 at 6.9 h and 9.8 h, respectively. The maximum current density (Imax) decreased marginally with the increase in HRT; it was 0.59 A/m2 at 3.0 h and decreased to 0.49 A/m2 and 0.33 A/m2 at 6.9 h and 9.8 h, respectively. The HRT-dependent decrease in electricity generation has been repeatedly observed in the MFC in previous studies [2,22,26]. This decrease was revealed by the low COD due to the extended time required for microbial degradation.
The MFCCEM had an OCV of 0.25–0.26 V, Imax of 0.089–0.13 A/m2, and Pmax of 0.0037–0.0081 W/m2, regardless of the HRT (Figure 2A,B, Table 1). The OCV, Imax, and Pmax for the MFCCEM were 60–70%, 22–26%, and 12–16% those of MFCAEM at similar HRTs, respectively. The stable but lower OCV, Imax, and Pmax in the MFCCEM indicates a limitation of the cathode reaction rate in the MFCCEM because of the pH imbalance in the MFCCEM [25].
The differences in the resistance between the MFCAEM and MFCCEM were considered by dividing the resistances by the anode (Ran) and cathode (Rca) resistances. The Ran values of the MFCAEM were 3.2, 3.4, and 6.9 mΩ·m2 at 3.3, 6.9, and 9.8 h, respectively. These values indicated that the COD accessibility in the anolyte affected the Ran (Figure 2D, Table 2). The Ran of the MFCCEM was 1.7–1.9 mΩ∙m2 and lower than that of the MFCAEM. In contrast, the Rca of MFCAEM was 13–19 mΩ∙m2 and approximately 27–43% that of the MFCCEM (41–49 mΩ·m2). These results indicated that the higher electricity production in the MFCAEM can be attributed to the lower Rca in the MFCAEM (Figure 2C, Table 2).
The Imax and Pmax of the MFCAEM were in the ranges observed in our previous study without carbon brushes and with 91 mg/L of COD [22], that is, 0.19–0.38 A/m2 and 0.038–0.081 W/m2, respectively. The enhancement of the carbon brushes was restricted due to the low COD and limitation of the cathode reaction in the MFCAEM.
According to the results presented in Section 3.1, Section 3.2 and Section 3.3, the superiority of the AEM as a separator in an air-cathode MFC was apparent. Therefore, the resistance of the cathode in MFCAEM was further investigated.

3.4. Linear Sweep Voltammetry

The color change of the AEM from clear to dark brown (Figure 3) after extended operation of the MFCAEM [22], motivated us to evaluate the effect of operation time on current production by the MFCAEM. The surface apparatus differed on either side of the AEM; the anode side was covered with a dark brown film, whereas the cathode side was covered with white precipitates. The effect of dirt on the current production was evaluated by LSV.
The LSV was performed using a small air-cathode fuel cell filled with sewage wastewater and using Pt as the anode catalyst under H2 supplementation to prevent the restriction of the microbial anode reaction (Supplementary Figure S1). The original AEM (AEM0) and AEMs (AEM35, AEM583, and AEM768) taken from the MFCAEM after 35, 583, and 768 days of operation exhibited a marginal increase in the slope, i.e., the cathode resistance (Rca-H2), with the increase in operation time (Figure 4). The Rca-H2 for all AEMs remained apparently unchanged at 8.0 ± 2.0 mΩ·m2 (Figure 4, Table 2). A similar Rca-H2 indicates a minor effect of dirt on the cathode resistance. The potential of the cells with AEM583 and AEM768 was marginally higher than that of AEM0 and AEM35, although the mechanism behind it is unknown.

3.5. Membrane Resistance in NaCl Solution

The AEM resistance measured in terms of the Cl mobility in the 0.5 M NaCl solution. In this experiment, AEMs were taken from the MFCAEM after operation times of 35, 583, and 768 d at depths of 20, 50, and 80 cm (Table 2 and Figure 5).
The membrane resistance (RM-Cl) of the original AEM was 0.31 mΩ·m2, which increased to 0.36, 0.37, and 0.61 mΩ·m2 in the MFCAEM at a depth of 50 cm after 35, 583, and 768 d, respectively. RM-Cl also tended to increase with increasing depth. For instance, for the MFCAEM at 583 d, the RM-Cl was 0.27 Ω·m2 at 20 cm, and it increased by 1.4 and 2.0 times at depths of 50 cm and 80 cm, respectively. This trend was also observed in the MFCAEM at 35 d, but the depth-dependent rate of increase was less than that at 583 d. After six weeks of AEM immersion in 0.5 M of NaCl, the surface dirt peeled off from the AEM, which resulted in a 97–110% recovery of RM-Cl compared to the original RM-Cl of AEM0. This indicates that the surface dirt caused a significant increase in RM-Cl, in contrast to the marginal increase resulting from the irreversible damage caused to the membrane.

3.6. Investigation of Dirt on Membrane

Ion chromatograph analysis of white precipitates on the cathode side of the AEM and CEM revealed the presence of Ca2+, Mg2+, and Na+ as cations for both membranes (Supplementary Figure S2). The AEMs obtained from the MFC operated for 583 d exhibited 0.21, 0.11, and 0.0037 mg/cm2 of Ca2+, Mg2+, and Na+, respectively. It is hypothesized that the cations are transferred from wastewater and through the AEM by the extreme water pressure. The CEM at 35 d exhibited 0.29, 0.019, and 0.047 mg/cm2 for Ca2+, Mg2+, and Na+, respectively. Cl was detected as an anion because 0.1 M of HCl was used as the solvent for both membranes. In contrast, the anode side of the AEM and CEM exhibited an apparent increase in microbial density (Supplementary Figure S3). These results indicate that Ca, Mg, and Na salts that are eluted from wastewater appear as precipitates on the cathode side and that microbial biofilm appears as the brown dirt on the anode side.

4. Conclusions

The comparison of air-cathode MFC performances equipped with the AEM and CEM indicated the superiority of the AEM as a separator. The use of AEMs reduced the cathode resistance by eliminating the pH imbalance observed in an air-cathode MFC equipped with a CEM. Moreover, the AEM showed an increase in membrane resistance as the Cl mobility with the increase in operation time and depth. This result indicates a potential increase in membrane resistance when using the AEM in large-scale MFCs at the meter scale for extended periods. However, the increase in membrane resistance marginally contributes to the cathode resistance with OH movement for less than 768 d and at a depth of less than 1 m.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/membranes12020183/s1, Figure S1: The illustration and apparatus of the reactor used for the LSV experiment; Figure S2: Identified ions precipitated on the cathode side of ion-exchange membranes in MFCs; Figure S3: Fluorescence microscopic images of microbes attached to the AEMs before MFC installation and 583 d after the operation.

Author Contributions

R.I., data curation and writing-original draft preparation; N.Y., writing—review and editing, supervision, project administration, funding acquisition; T.Y., data curation; Y.K., data curation; M.H., supervision. All authors have read and agreed to the published version of the manuscript.

Funding

This study was supported by JST A-step (Grant number: JPMJTM20EK), the MILT Sewage Applied Research Program, and the JSPS Joint Research Program with NSFC and was partially supported by Nippon Koei Co., Ltd. and Tamano Consultants Co., Ltd.

Informed Consent Statement

Not applicable.

Acknowledgments

We would like to thank Kazuki Iida and Hiroaki Kobayashi from Nippon Koei Co., Ltd. for coordinating the research collaboration, Mitsuhiro Sakoda and Akihiro Iwata from Tamano Consultants Co., Ltd. for their kind support in the reactor construction, and Takahiro Matsumura from TOYOBO Co., Ltd. for manufacturing the MFC core. We also thank the staff of the Nagoya City Waterworks and Sewerage Bureau for providing access to the test sites and advisory comments.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. UNESCO. The United Nations World Water Development Report 2021 Valuing Water; UNESCO: Paris, France, 2021; ISBN 9789231004346. [Google Scholar]
  2. Sugioka, M.; Yoshida, N.; Iida, K. On Site Evaluation of a Tubular Microbial Fuel Cell Using an Anion Exchange Membrane for Sewage Water Treatment. Front. Energy Res. 2019, 7, 91. [Google Scholar] [CrossRef]
  3. Lu, M.; Chen, S.; Babanova, S.; Phadke, S.; Salvacion, M.; Mirhosseini, A.; Chan, S.; Carpenter, K.; Cortese, R.; Bretschger, O. Long-term performance of a 20-L continuous flow microbial fuel cell for treatment of brewery wastewater. J. Power Source 2017, 356, 274–287. [Google Scholar] [CrossRef]
  4. Jin, P.; Gu, Y.; Shi, X.; Yang, W. Non-negligible greenhouse gases from urban sewer system. Biotechnol. Biofuels 2019, 12, 100. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  5. Franz, M. Phosphate fertilizer from sewage sludge ash (SSA). Waste Manag. 2008, 28, 1809–1818. [Google Scholar] [CrossRef]
  6. McCarty, P.L.; Bae, J.; Kim, J. Domestic wastewater treatment as a net energy producer-can this be achieved? Environ. Sci. Technol. 2011, 45, 7100–7106. [Google Scholar] [CrossRef]
  7. Logan, B.E.; Hamelers, B.; Rozendal, R.; Schröder, U.; Keller, J.; Freguia, S.; Aelterman, P.; Verstraete, W.; Rabaey, K. Microbial fuel cells: Methodology and technology. Environ. Sci. Technol. 2006, 40, 5181–5192. [Google Scholar] [CrossRef]
  8. AlSayed, A.; Soliman, M.; Eldyasti, A. Microbial fuel cells for municipal wastewater treatment: From technology fundamentals to full-scale development. Renew. Sustain. Energy Rev. 2020, 134, 110367. [Google Scholar] [CrossRef]
  9. Liu, H.; Logan, B.E. Electricity generation using an air-cathode single chamber microbial fuel cell in the presence and absence of a proton exchange membrane. Environ. Sci. Technol. 2004, 38, 4040–4046. [Google Scholar] [CrossRef]
  10. Nojavan, S.; Zare, K.; Mohammadi-Ivatloo, B. Application of fuel cell and electrolyzer as hydrogen energy storage system in energy management of electricity energy retailer in the presence of the renewable energy sources and plug-in electric vehicles. Energy Convers. Manag. 2017, 136, 404–417. [Google Scholar] [CrossRef]
  11. Zhang, H.; Sun, C. Cost-effective iron-based aqueous redox flow batteries for large-scale energy storage application: A review. J. Power Source 2021, 493, 229445. [Google Scholar] [CrossRef]
  12. Dong, Y.; Qu, Y.; He, W.; Du, Y.; Liu, J.; Han, X.; Feng, Y. A 90-liter stackable baffled microbial fuel cell for brewery wastewater treatment based on energy self-sufficient mode. Bioresour. Technol. 2015, 195, 66–72. [Google Scholar] [CrossRef] [PubMed]
  13. Hiegemann, H.; Littfinski, T.; Krimmler, S.; Lübken, M.; Klein, D.; Schmelz, K.G.; Ooms, K.; Pant, D.; Wichern, M. Performance and inorganic fouling of a submergible 255 L prototype microbial fuel cell module during continuous long-term operation with real municipal wastewater under practical conditions. Bioresour. Technol. 2019, 294, 122227. [Google Scholar] [CrossRef]
  14. Goto, Y.; Yoshida, N. Scaling up Microbial Fuel Cells for Treating. Water 2019, 11, 1803. [Google Scholar] [CrossRef] [Green Version]
  15. Rossi, R.; Jones, D.; Myung, J.; Zikmund, E.; Yang, W.; Gallego, Y.A.; Pant, D.; Evans, P.J.; Page, M.A.; Cropek, D.M.; et al. Evaluating a multi-panel air cathode through electrochemical and biotic tests. Water Res. 2019, 148, 51–59. [Google Scholar] [CrossRef]
  16. Cheng, S.; Liu, H.; Logan, B.E. Increased performance of single-chamber microbial fuel cells using an improved cathode structure. Electrochem. Commun. 2006, 8, 489–494. [Google Scholar] [CrossRef]
  17. Al Lawati, M.J.; Jafary, T.; Baawain, M.S.; Al-Mamun, A. A mini review on biofouling on air cathode of single chamber microbial fuel cell; prevention and mitigation strategies. Biocatal. Agric. Biotechnol. 2019, 22, 101370. [Google Scholar] [CrossRef]
  18. Liu, W.; Cheng, S.; Yin, L.; Sun, Y.; Yu, L. Influence of soluble microbial products on the long-term stability of air cathodes in microbial fuel cells. Electrochim. Acta 2018, 261, 557–564. [Google Scholar] [CrossRef]
  19. Pasternak, G.; Greenman, J.; Ieropoulos, I. Regeneration of the power performance of cathodes affected by biofouling. Appl. Energy 2016, 173, 431–437. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  20. Ge, Z.; He, Z. Long-term performance of a 200 liter modularized microbial fuel cell system treating municipal wastewater: Treatment, energy, and cost. Environ. Sci. Water Res. Technol. 2016, 2, 274–281. [Google Scholar] [CrossRef] [Green Version]
  21. Ge, Z.; Wu, L.; Zhang, F.; He, Z. Energy extraction from a large-scale microbial fuel cell system treating municipal wastewater. J. Power Source 2015, 297, 260–264. [Google Scholar] [CrossRef] [Green Version]
  22. Sugioka, M.; Yoshida, N.; Yamane, T.; Kakihana, Y.; Higa, M.; Matsumura, T.; Sakoda, M.; Iida, K. Long-term evaluation of an air-cathode microbial fuel cell with anion exchange membrane in a 226 L wastewater treatment reactor. Environ. Res. 2022, 205, 112416. [Google Scholar] [CrossRef] [PubMed]
  23. Rossi, R.; Wang, X.; Logan, B.E. High performance flow through microbial fuel cells with anion exchange membrane. J. Power Source 2020, 475, 228633. [Google Scholar] [CrossRef]
  24. Rossi, R.; Baek, G.; Saikaly, P.E.; Logan, B.E. Continuous Flow Microbial Flow Cell with an Anion Exchange Membrane for Treating Low Conductivity and Poorly Buffered Wastewater. ACS Sustain. Chem. Eng. 2021, 9, 2946–2954. [Google Scholar] [CrossRef]
  25. Rossi, R.; Logan, B.E. Using an anion exchange membrane for effective hydroxide ion transport enables high power densities in microbial fuel cells. Chem. Eng. J. 2021, 422, 130150. [Google Scholar] [CrossRef]
  26. Yamane, T.; Yoshida, N.; Sugioka, M. Estimation of total energy requirement for sewage treatment by a microbial fuel cell with a one-meter air-cathode assuming Michaelis–Menten COD degradation. RSC Adv. 2021, 11, 20036–20045. [Google Scholar] [CrossRef]
  27. Feng, Y.; Yang, Q.; Wang, X.; Logan, B.E. Treatment of carbon fiber brush anodes for improving power generation in air-cathode microbial fuel cells. J. Power Source 2010, 195, 1841–1844. [Google Scholar] [CrossRef]
  28. Yoshida, N.; Miyata, Y.; Iida, K. Current recovery from sewage wastewater using electrochemically oxidized graphite felt. RSC Adv. 2019, 9, 39348–39354. [Google Scholar] [CrossRef] [Green Version]
  29. Goto, Y.; Yoshida, N.; Umeyama, Y.; Yamada, T.; Tero, R.; Hiraishi, A. Enhancement of Electricity Production by Graphene Oxide in Soil Microbial Fuel Cells and Plant Microbial Fuel Cells. Front. Bioeng. Biotechnol. 2015, 3, 42. [Google Scholar] [CrossRef] [Green Version]
  30. Rossi, R.; Cario, B.P.; Santoro, C.; Yang, W.; Saikaly, P.E.; Logan, B.E. Evaluation of Electrode and Solution Area-Based Resistances Enables Quantitative Comparisons of Factors Impacting Microbial Fuel Cell Performance. Environ. Sci. Technol. 2019, 53, 3977–3986. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  31. Fujii, K.; Yoshida, N.; Miyazaki, K. Michaelis–Menten equation considering flow velocity reveals how microbial fuel cell fluid design affects electricity recovery from sewage wastewater. Bioelectrochemistry 2021, 140, 107821. [Google Scholar] [CrossRef]
  32. Mehdizadeh, S.; Yasukawa, M.; Abo, T.; Kakihana, Y.; Higa, M. Effect of spacer geometry on membrane and solution compartment resistances in reverse electrodialysis. J. Memb. Sci. 2019, 572, 271–280. [Google Scholar] [CrossRef]
  33. Goto, Y.; Yoshida, N. Microbially reduced graphene oxide shows efficient electricity ecovery from artificial dialysis wastewater. J. Gen. Appl. Microbiol. 2017, 63, 165–171. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  34. Yoshida, N.; Miyata, Y.; Mugita, A.; Iida, K. Electricity recovery from municipal sewage wastewater using a hydrogel complex composed of microbially reduced graphene oxide and sludge. Materials 2016, 9, 742. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  35. Logan, B.; Cheng, S.; Watson, V.; Estadt, G. Graphite fiber brush anodes for increased power production in air-cathode microbial fuel cells. Environ. Sci. Technol. 2007, 41, 3341–3346. [Google Scholar] [CrossRef]
  36. Nagahashi, W.; Yoshida, N. Comparative evaluation of fibrous carbons and bamboo charcoal in the recovery of current from sewage wastewater. J. Gen. Appl. Microbiol. 2021, 67, 248–255. [Google Scholar] [CrossRef] [PubMed]
  37. Lanas, V.; Ahn, Y.; Logan, B.E. Effects of carbon brush anode size and loading on microbial fuel cell performance in batch and continuous mode. J. Power Source 2014, 247, 228–234. [Google Scholar] [CrossRef]
Figure 1. Current production by MFCAEM and MFCCEM throughout the operation. * Indicates the times when the data logger had trouble with the MFC. Purple and yellow arrows indicate the timing for PI curve or COD analysis, respectively.
Figure 1. Current production by MFCAEM and MFCCEM throughout the operation. * Indicates the times when the data logger had trouble with the MFC. Purple and yellow arrows indicate the timing for PI curve or COD analysis, respectively.
Membranes 12 00183 g001
Figure 2. Effects of ion selectivity of the membrane separator on electricity and potential. Panels (A,B) present power density (A) and cell voltage (B) with varied currents, respectively. Panels (C,D) present cathode (C) and anode potential (D) at different current densities, respectively.
Figure 2. Effects of ion selectivity of the membrane separator on electricity and potential. Panels (A,B) present power density (A) and cell voltage (B) with varied currents, respectively. Panels (C,D) present cathode (C) and anode potential (D) at different current densities, respectively.
Membranes 12 00183 g002
Figure 3. Change in AEM appearance with operation age.
Figure 3. Change in AEM appearance with operation age.
Membranes 12 00183 g003
Figure 4. Effect of AEM age on cathode reaction in an H2-oxidizing air-cathode fuel cell filled with sewage wastewater as anolyte.
Figure 4. Effect of AEM age on cathode reaction in an H2-oxidizing air-cathode fuel cell filled with sewage wastewater as anolyte.
Membranes 12 00183 g004
Figure 5. Membrane resistance (RM-Cl) as Cl mobility of AEMs taken from different depths and operation times. Panels (A,B) indicate RM-Cl of the AEMs after 1 h and 6 weeks of immersion in 0.5 M NaCl, respectively.
Figure 5. Membrane resistance (RM-Cl) as Cl mobility of AEMs taken from different depths and operation times. Panels (A,B) indicate RM-Cl of the AEMs after 1 h and 6 weeks of immersion in 0.5 M NaCl, respectively.
Membranes 12 00183 g005
Table 1. Summary of operation conditions of the MFCAEM and MFCCEM and the resulting performances in COD-RE, CE, OCV, Imax, and Pmax.
Table 1. Summary of operation conditions of the MFCAEM and MFCCEM and the resulting performances in COD-RE, CE, OCV, Imax, and Pmax.
Operation Time
IEM Type44 d53 d65 d49 d72 d77 dAverage
(49, 72, 77 d)
HRT [h]AEM3.36.99.86.47.67.37.1 ± 0.7
CEM3.06.98.86.97.37.37.2 ± 0.3
CODIN [mg/L]AEM---230230170210 ± 4 0
CEM---230230170210 ± 40
CODEF [mg/L]AEM---73695766 ± 9.0
CEM---150767099 ± 51
COD-RE [%]AEM---68706769 ± 2.0
CEM---35675954 ± 19
CE [%]AEM---1.71.21.81.6 ± 0.4
CEM---0.850.270.460.50 ± 0.35
OCV [V]AEM0.430.370.39----
CEM0.260.260.25----
Imax [A/m2]AEM0.590.490.33----
CEM0.130.110.089----
Pmax [W/m2]AEM0.0640.0470.032----
CEM0.00810.00750.0037----
Table 2. Summary of resistance measured in this study.
Table 2. Summary of resistance measured in this study.
Time (d)Depth [cm]Ran-MFCCEM [mΩ·m2]Rca-MFCCEM [mΩ·m2]Ran-MFCAEM [mΩ·m2]Rca-MFCAEM [mΩ·m2]Rca-H2 [mΩ·m2]RM-Cl [mΩ·m2]RM-Cl * [mΩ·m2]
0 6.70.31-
44 1.8413.213 --
53 1.9493.413 --
65 1.7446.919 --
3520 0.340.32
3550 100.360.30
3580 0.380.29
58320 0.270.22
58350 7.50.370.28
58380 0.530.39
76850 7.70.610.32
Depth: depth from the water surface [cm]; Ran: anode resistance of the MFC; Rca: cathode resistance of the MFC; Rca-H2: cathode resistance of the H2 oxidizing fuel cell; RM-Cl: membrane resistance; * RM-Cl measured after immersion for 6 weeks.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Itoshiro, R.; Yoshida, N.; Yagi, T.; Kakihana, Y.; Higa, M. Effect of Ion Selectivity on Current Production in Sewage Microbial Fuel Cell Separators. Membranes 2022, 12, 183. https://doi.org/10.3390/membranes12020183

AMA Style

Itoshiro R, Yoshida N, Yagi T, Kakihana Y, Higa M. Effect of Ion Selectivity on Current Production in Sewage Microbial Fuel Cell Separators. Membranes. 2022; 12(2):183. https://doi.org/10.3390/membranes12020183

Chicago/Turabian Style

Itoshiro, Ryoya, Naoko Yoshida, Toshiyuki Yagi, Yuriko Kakihana, and Mitsuru Higa. 2022. "Effect of Ion Selectivity on Current Production in Sewage Microbial Fuel Cell Separators" Membranes 12, no. 2: 183. https://doi.org/10.3390/membranes12020183