Article

Treatment of Olive Mill Wastewater through Integrated Pressure-Driven Membrane Processes

Department of Chemistry and Industrial Chemistry, University of Genoa, via Dodecaneso 31, 16141 Genova, Italy
*
Author to whom correspondence should be addressed.
Membranes 2020, 10(11), 334; https://doi.org/10.3390/membranes10110334
Submission received: 14 August 2020 / Revised: 7 November 2020 / Accepted: 9 November 2020 / Published: 11 November 2020
(This article belongs to the Special Issue Membranes for Water and Wastewater Treatment)

Abstract

:
The disposal of wastewater resulting from olive oil production (olive mill wastewater, OMW) is a major issue for olive oil producers. This wastewater is among the most polluting due to the very high concentration of organic substances and the presence of hardly degradable phenolic compounds. The systems proposed for OMW treatment are essentially based either on conventional chemical-physical, biological and thermal processes, or on membrane processes. With respect to conventional methods, membrane processes allow to separate different species without the use of chemicals or heat. This work deals with the use of the integrated pressure-driven membrane processes for the treatment of OMW. They consist of a first stage (microfiltration, MF) in which a porous multichannel ceramic membrane retains suspended materials and produces a clarified permeate for a second stage (reverse osmosis, RO), in order to separate (and concentrate) dissolved substances from water. Laboratory scale experiments with different small flat sheet RO membranes were first carried out in order to select the most appropriate one for the successive bench scale tests with a spiral wound module having a large membrane surface. The aim of this test was to concentrate the dissolved substances and to produce water with low salinity, chemical oxygen demand (COD), and reduced phytotoxicity due to a low content of phenolic compounds. The trend of the permeate flux and membrane retention as a function of the volume concentration ratio was investigated. The influence of OMW origin and its aging on the membrane performance was also studied.

Graphical Abstract

1. Introduction

Olive oil mill wastewater (OMW) is a by-product of the olive oil extraction process produced seasonally in a large quantity. Niaounakis and Halvadakis in their book [1] estimated a generation of OMW in the range of 10–30 million m3/year in 2006 and we should expect that since then, its quantity has increased in accordance with the increase in world olive oil consumption, which from 2006 to 2019 has grown from about 2.6 to 2.97 million tons [2,3].

1.1. OMW Composition

The OMW consists mainly of olive fruit vegetation water (more than 50% of the fruit) and water added during the extraction process. The composition of OMW is affected by the variety and ripeness of the olives and by the system used for their processing (pressure or centrifugation mills). For example, the centrifugation step in three-phase olive mill processing, the most common olive oil extraction system, generates an amount of OMW more than two times higher than that of olive oil produced. An average OMW composition can be given as 83.2% of water, 1.8% of inorganic salts and 15% of organic constituents, among which 7.5% of sugars [4]. OMW is characterized by a low pH, a high electrical conductivity and a chemical oxygen demand (COD), which can be as high as 200 g/L. The three-phase process (3P) generates the greatest amount of OMW, about 1–1.2 m3/tons of olives, while the two-phase process generates the least amount, about 0.085–0.1 m3/tons of olives. The batch-pressing process produces about 0.4–0.6 m3/tons of olives of OMW [5]. Nevertheless, all the three types of OMW are highly pollutant. Due to the presence of several organic compounds, among which there is a phenolic fraction, untreated OMW has broad-spectrum toxicity against bacteria, plants and animals [6], which implies treatment and environmental problems. However, phenols presence in OMW makes this problematic by-product (wastewater) a potential source for recovery of precious antioxidants. For the abovementioned reasons, OMW treatment systems are not only supposed to be flexible and efficient in reducing COD and salinity, they also should be a viable alternative for recovery of high added value phenolic compounds.

1.2. OMW Membrane-Based Treatment Processes

The systems proposed for OMW treatment are essentially based either on conventional biological, chemical, physicochemical and thermal processes [7,8,9] or advanced membrane processes [10,11,12,13,14,15,16]. The latter, especially pressure-driven processes (microfiltration (MF), ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO)), offer several advantages over traditional technologies, mainly in terms of low energy consumption, no additive requirements and no phase change, and thus, the possibility to preserve the original characteristics of treated effluents.
Gebreyohannes et al. [17] in 2016 reviewed both the literature and patents about the application of integrated membrane technologies for OMW treatment and they highlighted the polarization and fouling problems occurring in the pressure-driven membrane processes, which are mainly related to the particular composition of the OMW (e.g., solids, pectins, etc.). Again in 2016, Pulido [18] reviewed in detail the open literature on the application of membrane technologies in OMW treatment as well as on the main obstacles for their cost-effective utilization, namely the related fouling problems. He highlighted the need for a pretreatment before the integrated membrane process to limit the fouling phenomena and to achieve more stable operating permeate fluxes.
Typically, the proposed integrated pressure-driven membrane processes are based on the combination of steps for the removal of suspended solids (e.g., microfiltration or ultrafiltration) and of a second step aimed at the pollutant concentration and clean water recovery (e.g., nanofiltration and/or reverse osmosis). A fractionation of the pollutants contained in the OMW is technically feasible [19,20] but the application of such a process scheme composed by several steps of MF and UF with different molecular weight cut-off (MWCO), NF and RO is very expensive and often quite sophisticated for its implementation into small and medium olive mills.
Membrane processes have been applied to all the three types of OMWs (Table 1). The content of total suspended solids (TSS) and others minor components such as fats and pectins makes imperative a feed pretreatment before the NF or RO processes. Considering that the pH for the types of OMWs is similar, the electrical conductivity (EC) reflects the concentration of organic electrolytes and salts. The two-phase process shows the lowest electrical conductivity or solid residue. On the other hand, the two-phase process generates a solid, known as alperujo, which is a very pollutant waste to handle since it contains most of the organic compounds that in the three-phase process are released in the wastewater [5].
Cassano et al. [9] studied the application of UF polymeric membranes (MWCO between 4 and 10 kDa) and they observed a flux decrement up to 50% over 300 min operating time. The best performing membrane was made of regenerated cellulose. The flux recovery after cleaning with an alkaline detergent at 40 °C was claimed enough to recover the initial water flux. In any case, the raw OMW was subjected to preventive microfiltration step at 0.2 micron. Garcia Castello et al. [11] studied the combination of MF, NF followed by an osmotic distillation. In the MF step a 0.2 µm membrane was used and a strong flux decrease was observed without any tendency of stabilization. The cleaning procedure was carried out by using a concentrated alkaline solution of 20 g/L NaOH at 40 °C for 30 min followed by tap water rinsing. An irreversible fouling was observed with a loss of flux of about 50%. The flux reduction in the NF membrane (Nadir N30F spiral-wound membrane module) was about 35% after about 1 h operation at a volume reduction factor of about 3. The NF membrane after cleaning with 1g/L of NaOH as done for MF completely recovered its initial water flux. From the cited investigations it seems that although UF underwent severe fouling the initial flux could be recovered in most of the cases by a chemical alkaline cleaning procedure.
Bazzarelli et al. [28] proposed an integrated membrane process based on a MF/NF and osmotic distillation and membrane emulsification. For the MF step, a 0.14 μm ceramic membrane was used and the good results in the MF flux stability were ascribed to an acidification step at pH 1.8 and a subsequent filtration on a stainless steel filter [29]. The chemical cleaning protocol was still based on the use of an alkaline detergent at 40 °C for 30 min. Chemical physical pretreatments before the integrated pressure-driven membrane processes were studied in order to improve the performance of the integrated membrane process. Pulido et al. [30] applied a pretreatment based on a Fenton process, then directly followed by NF. Nevertheless, the direct application of tighter membrane processes (NF or RO) after a physical chemical secondary treatment can lead to cake formation on the membrane surface as reported for RO membranes [31].
Recently, the possibility of using a water-ethanol mixture for the extraction of polyphenols and their purification by integrated membrane processes was explored [32]. Although it opens up an interesting perspective, additional investigations should be carried out in order to define the quality of the reverse osmosis permeate and its ethanol content. With the aim of recovering valuable polyphenols, most of the studies investigated the integration of ultrafiltration (UF) and (NF). De Almeida et al. [22] showed that despite the combination of UF and NF, the COD and total phenols removal can be 83.3 and 93.1%, respectively. Despite the interesting results, the quality of the permeate water is still far from being disposed in the sewage under the parameters imposed by the legislation. Therefore, to meet the current disposal regulations a further treatment or filtration step of the NF permeate is clearly necessary.
Another integration scheme relied on the direct use of RO instead or in addition to the NF. Tundis et al. [33] showed the recovery and classification of polyphenols by using a MF step on a 0.1 µm TiO2 membrane followed by a NF step and a RO step based on a membrane typically applied to brackish water. Although a flux decay was observed for all the membrane filtrations, as the aim of the work was about the characterization of the polyphenols in the concentrate, the quality of the final NF and RO permeates was not assessed by the authors. Zagklis et al. [34] in a recent paper mentioned the design of a full system based on UF/NF/RO integrated with adsorption steps and solid-liquid extraction with the aim of recovering the polyphenolic fractions from both OMW and other types of phenolic containing wastewater (e.g., grape marc and olive leaves). Coskun et al. [35] in their lab scale study proposed centrifugation as a primary step followed by UF and finally by RO. Their study was exclusively focused on the rejection performance of the different membranes. Petrotos et al. [36] studied some relevant operational parameters on a pilot scale, a process integrating MF followed by a NF (or open RO) and then by RO using tubular membranes.
The problem of OMW is clearly urgent from the point view of its environmental impact and the technological solution that requires it to be simple, cost-effective and reliable, especially in countries where the size of working olive mills is still small. Integrated pressure-driven processes, which include RO as a final step, should enable the production of a permeate water of sufficient quality not only for its safe discharge into sewage, but also for any kind of reuse into a farm or olive oil production process.
Membrane processes were shown to be very effective in the treatment of numerous industrial effluents and wastewaters. However, their successful application depends on the proper choice of process configuration and process conditions, and these are the focus of the experimental study presented here. In this work, two consecutive pressure-driven membrane processes, namely microfiltration and reverse osmosis, are proposed for OMW treatment in order to obtain a RO permeate composed of water with a low salinity, COD, and reduced phytotoxicity due to very low content of phenolic compounds, which are retained and concentrated by the RO membrane. To this aim, laboratory scale tests were first carried out with small flat sheet RO membrane samples in order to select the most suitable membrane for the successive pilot scale investigation with a spiral wound element with a large membrane surface area. The high concentrations of suspended materials in OMW imposed the use of microfiltration as a pretreatment system for the RO, in order to avoid plugging of the feed spacer of the spiral wound elements. Ceramic multichannel elements with excellent thermal stability and chemical resistance to withstand severe cleaning cycles were used for microfiltration in order to easily remove particulates that can foul the membrane or plug the channels. This work deals with practical aspects and problems connected to the concentration of large volumes of OMW with MF/RO pilot plants and to OMW storage that were not investigated enough in the literature.

2. Materials and Methods

Since characteristics of OMW may differ significantly from mill to mill, OMWs from three different olive mills, two located in Liguria and one in Tuscany, were employed. The names of these mills cannot be revealed for confidentiality reasons and a generic code composed of letters and numbers will be used to identify the three types of OMWs. OMWs were first stored in reservoir tanks to allow sedimentation of a large part of suspended materials and separation of a supernatant fluid, which was filtered through a filter bag with an opening of 200 µm prior to microfiltration.
Microfiltration of prefiltered OMW was performed in a batch operation mode with the plant schematically shown in Figure 1a, using three ceramic membranes (Membralox EP19-40, Pall Corp., Port Washington, NY, USA) arranged in parallel into a stainless steel housing (Figure 1b). The main properties of these membranes are shown in Table 2.
The MF retentate was completely recycled to the feed tank while the clean permeate was continuously withdrawn to be used for RO test. As can be seen from Figure 1a, OMW is fed by the centrifugal pump to the membrane module with a velocity v = 3.9 m/s (calculated from the ratio between the feed flow rate measured by the flow meter, F, and the membrane channels cross-section) at an average pressure P = 2.3 bar, unless otherwise reported, measured by two manometers, P1 and P2, located before and after the membrane module, respectively. The permeate flow rate is simply evaluated by measuring with a graduated tank the time necessary to produce a given permeate volume. Permeate flux is then calculated from the ratio between the permeate flow rate and the overall filtration surface area. The temperature measured by the thermometer, T, is kept constant at 30 °C by a cooling device immersed into the feed tank. An electric immersion heater in the cleaning tank provides a rapid heating of the cleaning solutions (NaOH and/or NaOCl solutions) used to remove foulants from the membrane.
The scheme of the RO plant is very similar to that of the MF plant shown in Figure 1a. The main differences are related to the feed pump (piston), the pressure control valve (globe valve), and the use of a variable frequency drive ‘inverter’ to control the feed flow rate, Q (speed pump). The experimental conditions adopted for RO experiments were: P = 30 bar (unless otherwise reported), Q = 1000 L/h, T = 25 °C. A small cell was used for preliminary tests with flat sheet membrane samples (surface 0.0066 m2) listed in Table 3. A cylindrical vessel was employed to house a spiral wound membrane module (SW30HR Dow-Filmtec, now DuPont, Wilmington, Deleware; 4” diameter, 40” length, membrane surface 7.9 m2) during the successive bench scale experiments. Preliminary tests with small flat membranes were carried out keeping the feed concentration constant, and continuously recycling both permeate and concentrate streams to the feed tank. Concentration tests with spiral wound module were performed in a batch operation mode, following the same procedure previously described for microfiltration of OMW. During both RO and MF experiments samples of different streams were collected for analysis.
Electrical conductivity, pH and suspended solids content were measured according to Standard Methods [37]. COD was determined with the spectrophotometric method using Merck Spectroquant@ test kits (Merck KGaA, Darmstadt, Germany). The method is analogues to EPA 410.4, US Standard Methods 5220 D, and ISO 15705. Phenols were determined with Folin–Ciocalteu reagent [38].

3. Results

3.1. Feed Pretreatment and Microfiltration

OMWs with quite different characteristics were received from three mills. In particular, the OMW3-SG was characterized by a very high load of suspended solids of small size with a negligible settling velocity and poorly retained by the filter bag as can be seen in Figure 2a, where the images of the three types of OMWs after settling and filtration treatment are reported for comparison. The darker color of samples OMW1-FR and OMW2-CA is connected to a high particle removal efficiency. However, even in these two cases (especially for OMW2-CA) the produced filtrates did not satisfy the requirements for the RO feed. This is apparent from the images of Figure 2b, where deposited solids after centrifugation (8000 rpm for 10 min) can be observed on the bottom of the centrifuge tube. Therefore, a post-filtration treatment with ceramic membrane with 0.2 µm pore size was employed for the removal of fine suspended solids and production of a suitable feed for RO [39]. The main physicochemical characteristics of the three types of OMW (after settling and bag filtration) fed to the microfiltration plant are reported in Table 4.
Figure 3 refers to the microfiltration tests and shows the behavior of permeate flux as a function of volume concentration ratio, VCR (i.e., the ratio between the volume of the initial feed and the volume of the final concentrate) for the three different pretreated (settled and filtered) OMWs. Gentle heating at 30 °C makes the feed (especially the OMW3-SG) more fluid with consequent reduction of the friction loss along the plant and improved performance of the centrifugal pump. The permeate flux at the beginning of the MF tests appears very close for the three OMWs, while increasing the VCR, OMWs behave differently, especially OMW3-SG. As far as OMW1-FR and OMW2-CA are considered, the permeate flux first slightly decreases and then tends to level off. With OMW3-SG, which contains a relevant amount of suspended materials, a strong and almost proportional decline of permeate flux with increasing the VCR is observed.
After a VCR = 2.1, the high viscosity of the concentrated OMW3-SG (Figure 4a) considerably reduces the performance (head and flow rate) of the centrifugal pump, thus the fluid velocity through the membrane channels is progressively lowered and membrane channels begin to plug. The permeate flux first falls and then continues the decrease slowly. Immediately after VCR = 2.85, a sudden increase of the pressure occurred and the pump reached its shut-off pressure. The test had to be stopped immediately and it was necessary to use a metal probe to unclog membrane channels (Figure 4b).
Moreover, an intense membrane cleaning with NaOH solution (2% w/w) and NaOCl (500 ppm Cl) at 60 °C for at least 60 min was used to remove the deposit remaining on the membrane surface and into the membrane pores. By measuring pure water flux before (JW,0) and after (JW,F) OMW filtration, a flux recovery ratio FRR = (JW,F/JW,0)·100 very close to 100% was achieved, thus demonstrating the effectiveness of the cleaning procedure. The other two types of OMWs (1-FR and 2-CA) did not plug membrane channels but severely fouled the membrane. The pure water flux after MF was around 30% of the original membrane flux, but even in this case a FRR ≈ 100% was obtained after the cleaning with NaOH and NaOCl.
The main physicochemical properties of feed (FD) and permeate (PR) samples collected at increasing VCR during the MF of the three types of OMW are listed in Table 5. Both pH and electrical conductivity of feed and permeate are substantially similar since dissolved ions pass through the pore of the membrane while a given retention is observed for COD due to the removal of suspended organic part, which contributes to this parameter. Phenol retentions seem to be high for the MF membrane, but according to previous literature findings [8], this fact can be ascribed to fouling, which may deeply alter the retention characteristics of membrane by itself.

3.2. Nanofiltration and Reverse Osmosis

The results of NF/RO screening tests with small flat sheet membranes carried out by using the MF permeate of OMW2-CA as feed are reported in Table 6. Except for Desal DK, all the other membranes present very high solute retention. To obtain useful products from OMW such as purified water (permeate) and a polyphenols rich solution (concentrate), a membrane with the highest possible retention to salts, COD and phenols are required. Table 6 reveals that SW30HR membrane (DOW) completely meets these requirements. Therefore, this membrane in a spiral wound configuration was selected for successive bench-scale tests.
The results of the RO concentration test carried out with the MF permeate of OMW1-FR are shown in Figure 5. By increasing the VCR, the permeate flux decreases first rapidly and then slowly until reaching VCR = 10.5, a value (around 1 L/(m2∙h)) ca. 30 times lower than that of the initial flux (VCR = 1). The observed flux decline with increasing VCR can be ascribed to the increase of the osmotic pressure of the feed, as well as concentration polarization and fouling phenomena.
The osmotic pressure of the concentrated solution (VCR = 10.5) can be estimated by measuring the permeate flux at increasing pressures and a constant feed concentration as shown in Figure 6. The differences in pure water flux (Figure 7) measured before and after OMW treatment are connected to the membrane fouling. Only a moderate cleaning with a NaOH solution (pH = 11) at 40°C was sufficient for eliminating fouling and achieving FRR around 100%.
Figure 8 and Figure 9 show the behavior of the permeate flux as a function of VCR during the RO concentration of the permeates produced by microfiltration of OWM2-CA and OWM3-SG. The trends are similar to that shown in Figure 5. The permeate flux improves at higher pressure but continues to fall with the increase in the VCR. A worse membrane performance is observed according to the considerably higher solute content of these OMWs as shown in Table 7. Further inspection of Table 7 reveals high retention values for conductivity and COD and an excellent abatement of phytotoxic phenol fraction. As expected, the retention worsens with VCR and improves with the pressure (since water flux through the membrane increases with the pressure while the solute diffusion is independent of pressure).
The effect of OMW age on the performance of the membrane is shown in the following Figure 10 and Figure 11 and in Table 8. It is worth noticing that olive oil extraction is a seasonal operation whose duration is around 4–5 months during the winter. The amount of OMW is much higher than that of olive oil produced, and consequently very large plants are necessary for the treatment of all the wastewater generated daily, otherwise it must be stored. To obtain preliminary information on the influence of OMW storage/aging on the performance of the integrated membrane process, a given amount of OMW2-CA was allowed to rest for ca. 4 months. After this long settling period, the supernatant liquid was filtered through the usual filter bag and the resulting filtrate was sent to the MF plant. From the results reported in Figure 10, a given increase of the permeate flux of the stored OMW is observed. This increase is connected to a lower content of suspended material (TSS = 420 mg/L) due to the 4 months settling period. Conversely, only a moderate variation of the permeate flux during the RO experiments (Figure 11) occurs since the amount of dissolved solids does not practically change during the storage, as can be seen from physicochemical characterization results shown in Table 8. From the same table it is apparent that the storage period does not affect membrane retention.

4. Discussion

4.1. Pretreatment and Microfiltration

As reported in Table 1 and Table 3, OMW contains relevant concentrations of TSS. Therefore, any type of membrane process aimed at polyphenol recovery as well as water reuse needs a pretreatment to remove TSS. The removal of TSS is of crucial importance for the fouling control of the NF or RO process.
Cassano et al. [12] pretreated the raw OMWs by using a commercial tubular MF membrane module (pore size 0.2 µm, polypropylene, 5.5 mm inner diameter). Then, UF polymeric membranes were used to produce a clear permeate to be fed to the nanofiltration unit. Nevertheless, for all the UF membranes, a flux decay was observed. Bazzarelli et al. [29] studied the change of pH to destabilize the solid suspension in OMW and they showed that a pretreatment based on MF or UF can be effective at removing the suspended solids. MF exhibits higher fluxes than UF and ceramic membranes showed the highest fluxes. In another interesting approach of MF by using polymeric hollow fiber membranes, a fouling control was attempted by the deposition on the membrane surface of a photoactive gel [40].
Garcia–Castello et al. [11] reported the performance of a 0.2 µm alumina membrane after several filtration runs. During each run, a consistent flux decay was observed and even after a cleaning procedure with 20 g/L NaOH at 40 °C the water flux of the virgin membrane was not fully recovered.
In our work, we proposed the use of a ceramic MF membrane due to its high chemical and thermal stability during the cleaning procedures to restore its performance. We also observed an evident decay of the flux (Figure 3), but on the other hand, a chemical cleaning with alkaline agents combined with the use of a sufficiently high temperature (about 60 °C for at least 1 h) we restored the initial membrane performance. The effect of the temperature during the chemical cleaning was remarked in a recent work also by Fraga et al. [41], where the use of high permeability silicon carbide MF membranes was investigated.
The MF ceramic membrane module tested with all the three OMWs was able to preserve the subsequent NF or RO spiral wound modules from plugging problems. Since MF can seriously suffer from plugging and fouling phenomena at high TSS, the use of chemically-resistant membranes seems to be essential, especially if the plant is designed to be used only seasonally.

4.2. Nanofiltration and Reverse Osmosis

SW30HR membrane showed the best retention of COD and phenols among the tested NF and RO membranes. By increasing the VCR, the retention to phenols was always very high (>99.3%) and the retention to COD had generally been about 95%. The highest VCR obtained was limited by the increase of the osmotic pressure. As shown, at VCR = 10.5 the experimental osmotic pressure was approaching 29 bars. The electrical conductivity of pristine OMW1-FR was 5310 µS/cm, while for OMW2-CA and OMW3-SG, the electrical conductivities were very close, 13,940 µS/cm, 12,780 µS/cm, respectively (Table 4). Since the electrical conductivity is mainly related to the concentration of dissolved salts, with the OMW1-CA it was possible to achieve a higher VCR than for the other two OMWs. The different behavior between OMW2-CA and OMW3-SG during the RO concentration is therefore mainly related to the different level of organic compounds, considering that the ratio of COD between the OMW3-SG and OMW2-CA is about 2. A pressure increase seems to be beneficial to both the flux and the retention.

4.3. Remarks

On the basis of our results and of the findings reported in the literature, integrated membrane processes are able to efficiently produce a polyphenols-rich concentrate. The recovery of polyphenols is very interesting, since they are valuable compounds that can be supplied to cosmetic and pharmaceutical industries. Nevertheless, the exploitation of polyphenols-rich streams is still facing some technological challenges related to the polyphenol fractionation. The main driver to develop processes for the treatment of OMW is the environmental pressure in order to limit the pollution related to their production and disposal. A clean water stream can be obtained when an RO process is considered as a final step. In the proposed integrated membrane process, the high retention of polyphenols can allow the separation of good quality water already after a first RO stage, which can be more easily accepted by a sewage depuration system since the residual COD is no longer related to the presence of polyphenols. The permeate water can be considered also for an internal reuse in the olive mill after and eventual refining treatment (a second RO stage or adsorption) as well as for irrigation purposes. The main process issues are related to controlling the fouling. Ceramic membranes have proved their suitability since they can withstand aggressive chemical cleaning procedures, and although their cost is still high compared to that of polymeric membranes, they can guarantee a longer lifetime. Since in many countries olive mills are still small enterprises, the investment costs for a membrane-based treatment plant can be more easily faced if there is the possibility of storing part of the OMWs generated during the milling season. In this work, we proved that the aging of the OMW does not critically affect the performance of the integrated membrane process.
Pulido and Martinez-Ferez in their review [42] identified the control of fouling as one of the limits of membrane technologies applied to OMW. Another bottleneck for a wide field application of the integrated membrane process remains, related to the options available for either the disposal or chemical/energetic valorization of the concentrate stream. These options should be evaluated on the specific characteristics and constraints of the olive mill willing to apply membrane technology.

5. Conclusions

MF/RO integrated membrane processes have been proposed for the treatment of OMW. The MF can be considered a suitable pretreatment for RO process since it provides a clean permeate, which does not cause plugging of the spiral wound element. RO separates dissolved substances from water, thus allowing the concentration of valuable products and produces water with a low salinity, COD, and phytotoxicity. Channel plugging and fouling of MF membrane represent a serious problem during the treatment of OWM, characterized by a high load of fine particles, which cannot be properly removed by simple settling or bag filtration. Therefore, ceramic membranes capable of withstanding hard cleaning agents are necessary. Membrane performance is not deeply affected by OWM aging and consequently, the wastewater may be treated gradually, without the need of large plants operating only a few months a year. This may involve important benefits connected to the reduction of investment costs and of bactericide solutions, which are necessary for a long-term storage of delicate RO membranes. The commercial RO membrane for seawater treatment, SW30 HR (Dow), showed a very high retention to polyphenols and dissolved species, which contribute to electrical conductivity. The increase of both osmotic pressure and organics concentration limited the maximum volume concentration ratio that could be achieved.

Author Contributions

Conceptualization, A.B. and G.C.; data curation, C.C. and A.J.; funding acquisition, G.C.; investigation, A.B., R.F., A.J. and M.P.; methodology, A.B. and A.J.; project administration, G.C. and A.C.; resources, A.C. and A.J.; supervision, A.B. and A.C.; visualization, A.J. and M.P.; writing—original draft, A.B. and A.J.; writing—review & editing, A.C. and M.P. All authors have read and agreed to the published version of the manuscript.

Funding

This research was conducted in the framework of the ENPI CBC Med Project: MEDOLICO I-B/2.1/090 (Mediterranean Cooperation in the Treatment and Valorisation of Olive Mill Wastewater, OMW).

Conflicts of Interest

The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.

References

  1. Niaounakis, M.; Halvadakis, C.P. Olive Processing Waste Management: Literature Review and Patent Survey, 2nd ed.; Waste Management Series; Elsevier: Amsterdam, The Netherlands, 2006; pp. 1–498. [Google Scholar]
  2. Trends in World Olive Oil Consumption. Available online: https://www.oliveoilmarket.eu/trends-in-world-olive-oil-consumption (accessed on 10 August 2020).
  3. Consumption of Olive Oil Worldwide from 2012/13 to 2019/20. Available online: https://www.statista.com/statistics/940491/olive-oil-consumption-worldwide/ (accessed on 10 August 2020).
  4. Kiritsakis, A.K. Olive Oil: From the Tree to the Table; Food & Nutrition Press Inc.: Trumbull, CT, USA, 1998. [Google Scholar]
  5. Tsagaraki, E.; Lazarides, H.N.; Petrotos, K.B. Olive Mill Wastewater Treatment. In Utilization of By-Products and Treatment of Waste in the Food Industry; Oreopoulou, V., Russ, W., Eds.; Springer: Boston, MA, USA, 2007; pp. 133–157. [Google Scholar]
  6. Obied, H.K.; Bedgood, D.R., Jr.; Prenzler, P.D.; Robards, K. Bioscreening of Australian olive mill waste extracts: Biophenol content, antioxidant, antimicrobial and molluscicidal activities. Food Chem. Toxicol. 2007, 45, 1238–1248. [Google Scholar] [CrossRef]
  7. Caputo, C.; Scacchia, F.; Pelagagge, P.M. Disposal of by-products in olive oil industry: Waste-to-energy solutions. Appl. Therm. Eng. 2003, 23, 197–214. [Google Scholar] [CrossRef]
  8. Paraskeva, P.; Diamadopoulos, E. Technologies for olive mill wastewater (OMW) treatment: A review. J. Chem. Technol. Biotechnol. 2006, 81, 1475–1485. [Google Scholar] [CrossRef]
  9. Yonar, T.; Mert, B.K.; Kestioglu, K.; Hung, Y.-T. Treatment of olive oil production wastewaters. In Handbook of Environment and Waste Management: Air and Water Pollution Control; Hung, Y.-T., Wang, L.K., Shammas, N.K., Eds.; World Scientific Pub: Singapore, 2012; Chapter 22; pp. 979–1014. [Google Scholar]
  10. Turano, E.; Curcio, S.; De Paola, M.G.; Calabrò, V.; Iorio, G. An integrated centrifugation–ultrafiltration system in the treatment of olive mill wastewater. J. Membr. Sci. 2002, 209, 519–531. [Google Scholar] [CrossRef]
  11. Garcia-Castello, E.; Cassano, A.; Criscuoli, A.; Conidi, C.; Drioli, E. Recovery and concentration of polyphenols from olive mill wastewaters by integrated membrane system. Water Res. 2010, 44, 3883–3892. [Google Scholar] [CrossRef] [PubMed]
  12. Cassano, A.; Conidi, C.; Drioli, E. Comparison of the performance of UF membranes in olive mill wastewater treatment. Water Res. 2011, 45, 3197–3204. [Google Scholar] [CrossRef]
  13. Ochando-Pulido, J.M.; Rodriguez-Vives, S.; Hodaifa, G.; Martinez-Ferez, A. Impacts of operating conditions on reverse osmosis performance of pretreated olive mill wastewater. Water Res. 2012, 46, 4621–4632. [Google Scholar] [CrossRef]
  14. El-Abbassi, A.; Kiai, H.; Raiti, J.; Hafidi, A. Application of ultrafiltration for olive processing wastewaters treatment. J. Cleaner Prod. 2014, 65, 432–438. [Google Scholar] [CrossRef]
  15. Zirehpour, A.; Rahimpour, A.; Jahanshahi, M. The filtration performance and efficiency of olive mill wastewater treatment by integrated membrane process. Desalin. Water Treat. 2015, 53, 1254–1262. [Google Scholar] [CrossRef]
  16. Hamza, M.; Sayadi, S. Valorisation of olive mill wastewater by enhancement of natural hydroxytyrosol recovery. Int. J. Food Sci. Tech. 2015, 50, 826–833. [Google Scholar] [CrossRef]
  17. Gebreyohannes, A.Y.; Mazzei, R.; Giorno, L. Trends and current practices of olive mill wastewater treatment: Application of integrated membrane process and its future perspective. Sep. Purif. Technol. 2016, 162, 45–60. [Google Scholar] [CrossRef]
  18. Pulido, J.M.O. A review on the use of membrane technology and fouling control for olive mill wastewater treatment. Sci. Total Environ. 2016, 563–564, 664–675. [Google Scholar] [CrossRef] [PubMed]
  19. Pizzichini, M.; Russo, C. Process for Recovering the Component of Olive Mill Wastewater with Membrane Technologies. WIPO Patent WO2005123603 A1, 29 December 2005. [Google Scholar]
  20. Galanakis, C.M.; Tornberg, E.; Gekas, V. Clarification of high-added value products from olive mill wastewater. J. Food Eng. 2010, 99, 190–197. [Google Scholar] [CrossRef]
  21. Ochando-Pulido, M.; Martinez-Ferez, A. Chapter 7: On the Purification of Agro-Industrial Wastewater by Membrane Technologies: The Case of Olive Mill Effluents. In Desalination; Taner, Y., Ed.; IntechOpen: London, UK, 2017; pp. 127–142. [Google Scholar] [CrossRef] [Green Version]
  22. De Almeida, M.S.; Martins, R.C.; Quinta-Ferreira, R.M.; Gando-Ferreira, L.M. Optimization of operating conditions for the valorization of olive mill wastewater using membrane processes. Environ. Sci. Pollut. Res. 2018, 25, 21968–21981. [Google Scholar] [CrossRef] [PubMed]
  23. Ochando-Pulido, M.; Corpas-Martínez, J.R.; Vellido-Perez, J.A.; Martinez-Ferez, A. Optimization of polymeric nanofiltration performance for olive-oil-washing wastewater phenols recovery and reclamation. Sep. Purif. Technol. 2020, 236, 116261. [Google Scholar] [CrossRef]
  24. Ochando-Pulido, J.M.; Stoller, M.; Martinez-Fereza, A. Boundary flux modelling for purification optimization of differently-pretreated agro-industrial wastewater with nanofiltration. Sep. Purif. Technol. 2018, 93, 147–154. [Google Scholar] [CrossRef]
  25. Ochando-Pulido, J.M.; Stoller, M.; Víctor-Ortega, M.D.; Martínez-Férez, A. Analysis of the Fouling Build-up of a Spiral Wound Reverse Osmosis Membrane in the Treatment of Two-phase Olive Mill Wastewater. Chem. Eng. Trans. 2016, 47, 403–408. [Google Scholar]
  26. Zagklis, D.P.; Vavouraki, A.I.; Kornaros, M.E.; Paraskeva, C.A. Purification of olive mill wastewater phenols through membrane filtration and resin adsorption/desorption. J. Hazard. Mater. 2015, 285, 69–76. [Google Scholar] [CrossRef]
  27. Paraskeva, C.A.; Papadakis, V.G.; Tsarouchi, E.; Kanellopoulou, D.G.; Koutsoukos, P.G. Membrane processing for olive mill wastewater fractionation. Desalination 2007, 213, 218–229. [Google Scholar] [CrossRef]
  28. Bazzarelli, F.; Piacentini, E.; Poerio, T.; Mazzei, R.; Cassano, A.; Giorno, L. Advances in membrane operations for water purification and biophenols recovery/valorization from OMWWs. J. Membr. Sci. 2016, 497, 402–409. [Google Scholar] [CrossRef]
  29. Bazzarelli, F.; Poerio, T.; Mazzei, R.; D’Agostino, N.; Giorno, L. Study of OMWWs suspended solids destabilization to improve membrane processes performance. Sep. Purif. Technol. 2015, 149, 183–189. [Google Scholar] [CrossRef]
  30. Ochando-Pulido, J.M.; Martinez-Ferez, A. Operation setup of a nanofiltration membrane unit for purification of two-phase olives and olive oil washing wastewaters. Sci. Total Environ. 2018, 612, 758–766. [Google Scholar] [CrossRef] [PubMed]
  31. Ochando-Pulido, J.M.; Víctor-Ortega, M.D.; Martínez-Ferez, A. Membrane fouling insight during reverse osmosis purification of pretreated olive mill wastewater. Sep. Purif. Technol. 2016, 168, 177–187. [Google Scholar] [CrossRef]
  32. Sygouni, V.; Pantziaros, A.G.; Iakovides, I.C.; Sfetsa, E.; Bogdou, P.I.; Christoforou, E.A.; Paraskeva, C.A. Treatment of two-phase olive mill wastewater and recovery of phenolic compounds using membrane technology. Membranes 2019, 9, 27. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  33. Tundis, R.; Conidi, C.; Loizzo, M.R.; Sicari, V.; Cassano, A. Olive Mill Wastewater Polyphenol-Enriched Fractions by Integrated Membrane Process: A Promising Source of Antioxidant, Hypolipidemic and Hypoglycaemic Compounds. Antioxidants 2020, 9, 602. [Google Scholar] [CrossRef]
  34. Zagklis, D.P.; Paraskeva, C.A. Preliminary design of a phenols purification plant. J. Chem. Technol. Biotechnol. 2020, 95, 373–383. [Google Scholar] [CrossRef]
  35. Coskun, T.; Debik, E.; Demir, N.M. Treatment of olive mill wastewaters by nanofiltration and reverse osmosis membranes. Desalination 2010, 259, 65–70. [Google Scholar] [CrossRef]
  36. Petrotos, K.B.; Kokkora, M.I.; Papaioannou, C.; Gkoutsidis, P.E. Olive mill wastewater concentration by two-stage reverse osmosis in tubular configuration, in a scheme combining open and tight membranes. Desalin. Water Treat. 2016, 57, 20621–20630. [Google Scholar] [CrossRef]
  37. American Public Health Association. Standard Methods for the Examination of Water and Wastewater, 15th ed.; American Public Health Association, American Water Works Association, Water Environment Federation: Washington, DC, USA, 1981. [Google Scholar]
  38. Singleton, V.L.; Orthofer, R.; Lamuela-Raventos, R.M. Analysis of total phenols and other oxidation substrates and antioxidants by means of Folin-Ciocalteu reagent. Methods Enzymol. 1999, 299, 152–178. [Google Scholar]
  39. Rodriguez, S.G.S. Particulate and Organic Matter Fouling of Seawater Reverse Osmosis Systems, Characterization, Modeling and Applications; CRC Press: Boca Raton, FL, USA, 2011. [Google Scholar]
  40. Han, Y.; Giorno, L.; Gugliuzza, A. Photoactive Gel for Assisted Cleaning during Olive Mill Wastewater Membrane Microfiltration. Membranes 2017, 7, 66. [Google Scholar] [CrossRef] [Green Version]
  41. Fraga, M.C.; Sanches, S.; Crespo, J.G.; Pereira, V.J. Assessment of a New Silicon Carbide Tubular Honeycomb Membrane for Treatment of Olive Mill Wastewaters. Membranes 2017, 7, 12. [Google Scholar] [CrossRef] [Green Version]
  42. Ochando-Pulido, J.M.; Martinez-Ferez, A. On the Recent Use of Membrane Technology for Olive Mill Wastewater Purification. Membranes 2015, 5, 513–531. [Google Scholar] [CrossRef] [PubMed] [Green Version]
Figure 1. (a) Schematic of the plant used for MF tests: V1-9 ball valves; GV gate valve; P1,2 manometers, T thermometer; F flowmeter. (b) Membralox module: 1—ceramic multi-channel membranes, 2—stainless steel membrane housing, 3—module end-cup, 4—clamps.
Figure 1. (a) Schematic of the plant used for MF tests: V1-9 ball valves; GV gate valve; P1,2 manometers, T thermometer; F flowmeter. (b) Membralox module: 1—ceramic multi-channel membranes, 2—stainless steel membrane housing, 3—module end-cup, 4—clamps.
Membranes 10 00334 g001
Figure 2. (a) Images of OMWs after settling and bag filtration. (b) Images of OMWs after centrifugation (h = TSS volume).
Figure 2. (a) Images of OMWs after settling and bag filtration. (b) Images of OMWs after centrifugation (h = TSS volume).
Membranes 10 00334 g002
Figure 3. Permeate flux versus volume concentration ratio (VCR) during the MF tests with different OMWs.
Figure 3. Permeate flux versus volume concentration ratio (VCR) during the MF tests with different OMWs.
Membranes 10 00334 g003
Figure 4. (a) OMW3-SG viscous concentrate after VCR = 2.1. (b) Removal of OMW3-SG muddy concentrate from the membrane channel with a metallic probe.
Figure 4. (a) OMW3-SG viscous concentrate after VCR = 2.1. (b) Removal of OMW3-SG muddy concentrate from the membrane channel with a metallic probe.
Membranes 10 00334 g004
Figure 5. Permeate flux as a function of VCR during RO test with the MF permeate of OMW1-FR.
Figure 5. Permeate flux as a function of VCR during RO test with the MF permeate of OMW1-FR.
Membranes 10 00334 g005
Figure 6. Permeate flux as a function of operating pressure at VCR = 10.5 (Feed: MF permeate of OMW1-FR).
Figure 6. Permeate flux as a function of operating pressure at VCR = 10.5 (Feed: MF permeate of OMW1-FR).
Membranes 10 00334 g006
Figure 7. Pure water flux as a function of operating pressure before and after RO test with MF permeate of OMW1-FR.
Figure 7. Pure water flux as a function of operating pressure before and after RO test with MF permeate of OMW1-FR.
Membranes 10 00334 g007
Figure 8. Permeate flux as a function of VCR during RO test with the MF permeate of OMW2-CA.
Figure 8. Permeate flux as a function of VCR during RO test with the MF permeate of OMW2-CA.
Membranes 10 00334 g008
Figure 9. Permeate flux as a function of VCR during RO test with the MF permeate of OMW3-SG.
Figure 9. Permeate flux as a function of VCR during RO test with the MF permeate of OMW3-SG.
Membranes 10 00334 g009
Figure 10. Effect of storage of OMW2-CA on the permeate flux as a function of VCR during MF test.
Figure 10. Effect of storage of OMW2-CA on the permeate flux as a function of VCR during MF test.
Membranes 10 00334 g010
Figure 11. Effect of storage of OMW2-CA on the permeate flux as a function of VCR during RO test with the MF permeate of OMW2-CA.
Figure 11. Effect of storage of OMW2-CA on the permeate flux as a function of VCR during RO test with the MF permeate of OMW2-CA.
Membranes 10 00334 g011
Table 1. Analytical characteristics of olive mill wastewater (OMWs) from the batch (BP), two-phase (2P) and three-phase (3P) processes and some integrated membrane processes proposed in literature.
Table 1. Analytical characteristics of olive mill wastewater (OMWs) from the batch (BP), two-phase (2P) and three-phase (3P) processes and some integrated membrane processes proposed in literature.
ProcesspHECTSSCODPhChProposed ProcessReferences
(mS/cm)(g/L)(g/L)(mg/L)(g/L)
BP4.5–5 0.1–2.765.7–1301.2–2.4%2.2–4.5 [5]
4.59.012%−180.0-- [21]
4.5-8.047.83740-UF-NF[22]
4.7-7.859.14560-
2P5.11.8-13.4749-NF[23]
5.252.1-14.0776-
5.52.2-4.2--NF[24]
4.91.75.616.4181-RO[25]
4.91.30.6%7.8 - [21]
3P4.7–5.2-0.9–27.640–103.40.37–0.5%1.5–4.7 [5]
5.0-17.6 212-MF-NF-OD[11]
--44107.2264012.3UF-NF-RO[26]
5.47.96.6%151.4-- [21]
5.135.0811.716.585013.1UF-NF-RO[27]
EC = Electrical conductivity; TSS = Total Suspended Solids; TOC = Total Organic Compounds; COD = Chemical Oxygen Demand; Ph = Polyphenols; Ch = Carbohydrates.
Table 2. Main properties of Pall–Membralox EP19-40 membrane used for MF tests.
Table 2. Main properties of Pall–Membralox EP19-40 membrane used for MF tests.
Channel Diameter4 mm
Number of Channels19
Filtration Surface Area0.24 m2
Length1020 mm
MaterialUltrapure α-alumina (>99.7%)
Pore size of the inner layer0.2 µm
Table 3. NF and RO membrane used during test cell experiments.
Table 3. NF and RO membrane used during test cell experiments.
MembraneManufacturerMinimum RejectionApplication
Desal AGGE Power&Water99.3% (NaCl)Brackish water RO
Desal SCGE Power&Water98.5% (NaCl)Brackish water RO
Desal DKGE Power&Water,98% (MgSO4)NF
SW30 HRDOW99.6% (NaCl)Seawater RO
SW30 ULEDOW99.55% (NaCl)Seawater RO
BW30DOW99.0% (NaCl)Brackish water RO
NF 90DOW97.0% (MgSO4), 85.0% (NaCl)NF
Table 4. Physicochemical properties of OMWs fed to the microfiltration plant.
Table 4. Physicochemical properties of OMWs fed to the microfiltration plant.
pH
(—)
TSS
(mg/L)
COD
(mg/L)
Conductivity
(µS/cm)
Phenols
(mg/L)
OMW1-FR4.4387030,00053102000
OMW2-CA5.80170066,50013,9401500
OMW3-SG5.1715,000159,50012,7803300
Table 5. Main physicochemical properties of feed (FD) and permeate (PR) samples collected during the MF tests with three different types of OMW.
Table 5. Main physicochemical properties of feed (FD) and permeate (PR) samples collected during the MF tests with three different types of OMW.
VCRpHConductivity (µs/cm)COD (mg/L)Phenols (mg/L)
FDPRFDPRR (%)FDPRR (%)FDPRR (%)
OMW1-FR
1.004.434.39531050504.9030,00019,78034.072000143028.50
1.294.444.39545053302.20
1.824.444.4542052902.4033,42520,45038.823900282027.69
3.074.54.41545052603.4938,70023,10040.314500320028.89
OMW2-CA
1.005.85.913,94013,6901.7966,50043,37034.78150099633.60
1.225.795.8813,60013,3501.8470,88940,99042.18
1.555.775.9113,56013,4101.1175,50042,44043.791590105033.96
2.145.795.8713,92013,6501.9485,00040,74052.07
3.455.815.913,99013,5003.5095,00042,85054.891910120037.17
OMW3-SG
1.005.175.2312,78012,2404.23128,80049,49061.583300195040.91
1.675.375.3812,47012,0603.29164,35055,35066.32
2.865.375.3912,47012,0503.37209,00064,59069.104800282041.25
Table 6. Results of the RO screening tests with different types of NF and RO membranes (P = 30 bar, T = 25 °C). Feed: MF permeate of OMW2-CA (Conductivity = 13,200 µS/cm; COD = 40,180 mg/L; Phenols = 1070 mg/L).
Table 6. Results of the RO screening tests with different types of NF and RO membranes (P = 30 bar, T = 25 °C). Feed: MF permeate of OMW2-CA (Conductivity = 13,200 µS/cm; COD = 40,180 mg/L; Phenols = 1070 mg/L).
MembranePermeate Flux
(L/m2h)
ConductivityCODPhenols
PR (µS/cm)R (%)PR (mg/L)R (%)PR (mg/L)R (%)
Desal AG7.00138.698.95260893.516.099.44
Desal SC14.35170.398.71232694.219.199.15
Desal DK60.61147388.84824979.47112.889.46
SW30 HR12.66109.699.17173695.682.999.73
SW30 ULE12.04151.898.85235994.134.499.59
BW3033.26159.798.79238794.069.099.16
NF 9027.27150.598.86266893.367.599.30
Table 7. Main physicochemical properties of feed (FD) and permeate (PR) samples collected during RO test with the MF permeates of three different types of OMW.
Table 7. Main physicochemical properties of feed (FD) and permeate (PR) samples collected during RO test with the MF permeates of three different types of OMW.
VCRP
(bar)
pHConductivity (µS/cm)COD (mg/L)Phenols (mg/L)
FDPRFDPRR (%)FDPRR (%)FDPRR (%)
OMW1-FR
1.00304.483.79510089.798.2419,65062896.8029006.099.79
1.96304.583.618880109.098.7736,17092697.44
6.56304.683.8320,900253.098.79
10.5030 26,700138294.82140,120255898.172430028.099.88
OMW2-CA
1.00305.884.8113,200116.399.1240,180201095.0010705.099.53
1.23305.874.8415,200133.499.1253,990223195.87
1.60305.864.8616,370199.298.7865,860249596.21
2.29305.94.918,910239.798.7386,960384095.58
4.00305.984.9220,490318.998.44109,220885591.89
5.33306.024.9627,400904.096.70151,70015,32589.90560057.398.98
6.15506.124.8930,200702.097.68191,350407597.87642024.299.62
OMW3-SG
1.00305.455.2712,100115.299.0558,560293394.9922502.299.90
1.2430 17,130128.499.2578,280318995.93
1.6230 20,500192.799.06104,320454395.65
2.33305.55.2125,800738.097.14120,80010,00091.72
2.7430 29,000159294.51159,22013,85591.30750054.099.28
3.6240 33,800173494.87215,85016,62092.30
4.57505.595.1636,100332090.80261,900872096.67985026.099.74
Table 8. Main physicochemical properties of feed (FD) and permeate (PR) samples collected during the RO test with “aged” OMW2-CA.
Table 8. Main physicochemical properties of feed (FD) and permeate (PR) samples collected during the RO test with “aged” OMW2-CA.
VCRP
(bar)
pHConductivity (µs/cm)COD (mg/L)Phenols (mg/L)
FDPRFDPRR (%)FDPRR (%)FDPRR (%)
1.00305.914.8213,500117.499.1340,200205094.9010255.299.49
1.14305.874.8414,200135.299.0544,500212095.24
1.33305.934.8515,300198.798.7055,450229095.87
1.60305.944.8716,450240.198.5467,800237096.50
2.00305.894.8317,930303.898.3184,300354095.80232011.099.53
2.67305.934.9019,800318.498.3998,650590094.02
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Bottino, A.; Capannelli, G.; Comite, A.; Costa, C.; Firpo, R.; Jezowska, A.; Pagliero, M. Treatment of Olive Mill Wastewater through Integrated Pressure-Driven Membrane Processes. Membranes 2020, 10, 334. https://doi.org/10.3390/membranes10110334

AMA Style

Bottino A, Capannelli G, Comite A, Costa C, Firpo R, Jezowska A, Pagliero M. Treatment of Olive Mill Wastewater through Integrated Pressure-Driven Membrane Processes. Membranes. 2020; 10(11):334. https://doi.org/10.3390/membranes10110334

Chicago/Turabian Style

Bottino, Aldo, Gustavo Capannelli, Antonio Comite, Camilla Costa, Raffaella Firpo, Anna Jezowska, and Marcello Pagliero. 2020. "Treatment of Olive Mill Wastewater through Integrated Pressure-Driven Membrane Processes" Membranes 10, no. 11: 334. https://doi.org/10.3390/membranes10110334

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics