Next Article in Journal
Analysis of the Productive, Structural, and Dynamic Development of Augmented Reality in Higher Education Research on the Web of Science
Previous Article in Journal
Tip Estimation Method in Phantoms for Curved Needle Using 2D Transverse Ultrasound Images
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Two-Stage Configuration of User-Side Hybrid Energy Storage Based on Fuzzy Optimization

1
School of Electrical Engineering, Southeast University, Nanjing 210096, China
2
School of Control Science and Engineering, Dalian University of Technology, Dalian 116024, China
3
Jiangsu Fangtian Power Technology Co., Ltd., Nanjing 210000, China
*
Author to whom correspondence should be addressed.
Appl. Sci. 2019, 9(24), 5307; https://doi.org/10.3390/app9245307
Submission received: 24 October 2019 / Revised: 28 November 2019 / Accepted: 29 November 2019 / Published: 5 December 2019
(This article belongs to the Section Energy Science and Technology)

Abstract

:
This paper proposes a new method for configuring hybrid energy storage systems on the user side with a distributed renewable energy power station. To reasonably configure the hybrid energy storage system, this paper divides the whole optimization into two stages from the two dimensions of capacity and power: supercapacitor and battery optimization. To minimize the fluctuation of new energy output when the user’s investment is as small as possible, a dual agent fuzzy optimization algorithm is used in the configuration of the supercapacitor. When the battery is configured, the optimization objective is to maximize the user’s income and minimize the number of charges and discharges in an optimization cycle. By dividing two objective functions, multi-objective optimization is integrated into single-objective optimization, the battery life is extended, and the total revenue of the user in the whole life cycle is increased.

Graphical Abstract

1. Introduction

Recently, due to the rapid development of the global economy, the power consumption on the user side has increased significantly [1], and the difference between peak and valley loads on the user side is increasing [2,3]. Therefore, with the further expansion of peak-valley difference of users’ electricity load, the government has established a two-part tariff system to encourage users to participate actively in load regulation [4]. The electricity charged by the two-part tariff in a charge cycle (CC) is as follows,
p = P p e a k × a + E × b
where P p e a k is the maximum load in the charge cycle, a is the demand price, E is the quantity of electricity consumed during the charge cycle, and b is the energy price.
Due to the increasing depletion of fossil fuels, many high-load industrial users are building photovoltaic power (PV) generation devices on the user side [5,6]. However, PV generation is greatly affected by light intensity and many other environmental factors [7,8], and its output fluctuates obviously. If directly connected to the grid, PV generation will affect the power quality and stability of the grid. Therefore, it is necessary to install energy storage devices (ES) in photovoltaic power generation system to suppress output fluctuations [9].
The power density and energy density when configuring ES on the user side need to be fully considered [10]. This paper establishes a hybrid energy storage model to suppress photovoltaic fluctuations, as shown in Figure 1. The expression of the load after configuration P l o a d a f t e r is
P l o a d a f t e r = P l o a d + P E S + P P V
where P l o a d is the original user load, P E S is the ES output (the discharge is negative, and the charge is positive), and P P V is the PV output.
In this paper, supercapacitors (SC) are selected as ES with high power density and lithium-ion batteries as ES with high energy density. This form of hybrid energy storage can reduce ES loss [11] and improve the power quality of the grid [12,13]. In [14], ES on the user side were divided into two layers: scheduling and operating. These two layers were optimized separately. R. Xiong et al. [15] proposed three evaluation indicators for the optimal allocation of ES on the user side from an economic point of view. In [16], the probabilistic weighted Markov process was used to predict future loads and determine the charging and discharging strategy based on state trajectory and ES loss. The whole life-cycle cost and benefit of ES were comprehensively considered in [17,18], but the model revenue part was too basic, and peak load reduction was not considered. Hu X. et al. [19] analyzed the pricing strategy under a fixed investment return period on the basis of three different mechanisms, but they did not consider the actual charging and discharging strategy, and the evaluation of the overall value of ES was incomplete.
To summarize, the existing optimal configuration schemes hardly consider prolonging the energy storage life from the point of reducing the number of charging and discharging cycles in each CC. There is seldom reference analyzing the impact of self-built distributed renewable energy generation on user-side ES configurations. Therefore, this paper establishes a two-stage multi-objective optimization model [20]. The optimization objective of the first stage is to suppress the fluctuation of PV output. The optimization objectives of the second stage are increasing the income of users’ ES investment and reducing the number of ES actions in each CC. The constraint conditions of this model include the limitation of the number of charging and discharging cycles, the SOC of ES, and the caps on ES investment.
The remainder of this paper is arranged as follows. The SC optimization model (Stage 1) and the large capacity battery optimization model (Stage 2) are introduced in Section 2. A two-stage optimization model based on fuzzy theory is proposed in Section 3. The case analysis is discussed in Section 4. Finally, the conclusion of paper is presented in Section 5.

2. Two-Stage Optimization Model of Hybrid Energy Storage on the User-Side

2.1. Stage 1: Supercapacitor Configuration

2.1.1. Model of Super Capacitor from the User’s Perspective

Taking the basic reference output as 1000 kW [21], the corresponding curve spectrum is solved by fast Fourier transform. In this paper, three common filtering algorithms are used to filter photovoltaic data: median filter (MF), wavelet transform (WT), and moving average filter (MAF) [22,23]. Because MF is very effective in smoothing impulse noise, it can protect the sharp edge curve of photovoltaic output by selecting the appropriate point to replace the bad point with large fluctuations. [24] MF is selected to process photovoltaic data in this paper. The time and frequency spectra of each waveform are shown in Figure 2. It can be seen from the Figure 2 that among the three filter algorithms, the median filtering output is the smoothest. The proportion of high-frequency components after filtering is shown in Table 1. In this paper, the price of a capacitor per unit capacity is set as c S C E , the price of a capacitor per unit power is set as c S C P , and then the mathematical model is established from the user’s point of view as follows.
M i n : C i n v e s t 1 = c S C P × P S C + c S C E × E S C
s . t . P S C , c h a , t P S C × B S C , c h a , t
P S C , d i s , t P S C × B S C , d i s , t
B S C , d i s , t + B S C , c h a , t 1
S O C S C ( t + 1 ) = S O C S C ( t ) η P S C ( t ) Δ t E S C
S O C S C m i n < S O C S C < S O C S C m a x
S O C S C i n i t i a l = S O C S C f i n a l
where P S C is the rated power of SC, E S C is the rated capacity of SC (discharge is positive, and charge is negative), and S O C S C is the SOC of SC, which has upper and lower limits of S O C S C m a x and S O C S C m i n , respectively. η is the charge–discharge coefficient, Δ t is the time interval. B S C , c h a , t and B S C , d i s , t are boolean variables, representing charge and discharge state constraints, B S C , d i s , t = 1 if SC is in the discharge state, B S C , d i s , t = 0 if SC is in the charge state, and B S C , c h a , t is the same as B S C , d i s , t . In the optimization model, the objective function indicates that the user wants capacitor investment to be as small as possible, and the constraints indicate that the charging state of the capacitor needs to be kept within the normal range. Capacitor charging and discharging upper limits are determined by the rated power of the capacitor.

2.1.2. Model of Power Quality from Grid’s Perspective

Due to the limitation of investment and operation of SC, it is difficult for SC to achieve the effect of the median filter and ideally suppress the fluctuations in photovoltaic output. Therefore, from the perspective of a power grid, it is necessary to establish a filter index R to minimize the proportion of high-frequency components in the total output:
M i n : R = f = f s a m p , f 0 f m a x Q f Q 0
where Q f is the high-frequency component of filtered output and f denotes frequency. This index represents the proportion of high-frequency output in the conventional output and minimizes the proportion under the normal operation of capacitors.

2.2. Stage 2: Large Capacity Battery Configuration

According to the IEC 600300-3-3 standard [25], under the two-part tariff system, the user’s tariff is closely related to the peak load on the grid side during the CC. According formula (2), the grid side load is related to the PV output after stabilization. Therefore, the user’s load after PV compensation is used as the underlying optimization parameter to input the battery optimization configuration model for optimization. The optimal allocation model of batteries in the life cycle is as follows.
Maximum total revenue:
M a x : C i n v e s t 2 = C i n c + C r e c C i n v e s t C m a i n t a i n
Minimum number of charging and discharging cycles:
M i n : N = t = 1 T B c h a ( t ) + t = 1 T B d i s ( t )
Energy storage scheduling revenue can be divided into demand and cost savings:
C i n c = C n e e d + C s t r a t e g y
C s t r a t e g y = y = 1 Y d a y = 1 D A Y ( t = 1 T d ( t ) ( P d i s , d a y , y ( t ) P c h a , d a y , y ( t ) ) Δ t ) ( 1 + i 1 + d ) y
C n e e d = y = 1 Y ( m = 1 M ( α δ P p e a k , m , y ) ) ( 1 + i 1 + d ) y
Energy storage recovery income:
C r e c = β C i n v e s t
Investment cost of energy storage:
C i n v e s t = c P P m a x + c E E m a x
Energy storage operation and maintenance cost:
C m a i n t a i n = y = 1 Y ( C m P m a x ) ( 1 + i 1 + d ) y
Constraint condition:
s . t . C i n v e s t C i n v e s t m a x
l o a d a f t e r = l o a d o u t p u t p v
l o a d a f t e r P d i s + P c h a ( 1 δ ) P p e a k , m , y
0 P d i s ( t ) P m a x B d i s ( t )
0 P c h a ( t ) P m a x B c h a ( t )
B d i s ( t ) + B c h a ( t ) 1
B denotes the state of charge and discharge. B d i s = 1 if energy storage is in the discharge state, B d i s = 0 if energy storage is in the charge state, and B c h a is the same as B d i s . Therefore, the sum of these two boolean variables can be used to calculate the total number of charging and discharging cycles.
S O C m i n < S O C b a t t e r y < S O C m a x
S O C b a t t e r y , i n i t i a l , m = S O C b a t t e r y , f i n a l , m
S O C b a t t e r y ( t ) = S O C b a t t e r y ( t 1 ) + [ η c h a P c h a ( t ) P d i s ( t ) / η d i s ] Δ t E m a x
where C i n c represents the benefit of peak-valley arbitrage, C s t r a t e g y , and demand savings C n e e d , C r e c is the revenue of recycling energy storage; C i n v e s t represents the energy storage investment; C m a i n t a i n represents the cost of energy storage operation and maintenance; P d i s , d a y , y denotes the discharge power of energy storage on the day-th day of the y-th year; and P c h a , d a y , y denotes energy storage charging power. α represents electricity demand price, δ denotes peak shaving rate, P p e a k , m , y represents the peak value of the original load in the m-th month of the y-th year. i denotes inflation rate, and d denotes the discount rate. P m a x denotes the rated battery power, and E m a x represents the rated capacity of the battery. d ( t ) denotes the peak-valley time-of-use tariff at t-time. η denotes the charge–discharge coefficient. The S O C constraints of the batteries are consistent with the S O C constraints of the supercapacitors.

3. Two-Stage Optimization Algorithm Based on Fuzzy Optimization

3.1. Multi-Objective Fuzzy Optimization

In the above model, there are two competing objective functions, and it is impossible for both of them to achieve the optimum at the same time. For the multi-objective programming problem, it is advisable to use the theory of fuzzy sets to transform the problem into a single-objective problem. On the premise of satisfying all constraints, considering user investment and smoothing photovoltaic output, the total cost of investing in supercapacitors and the total proportion of high-frequency components in the output need to be as small as possible. There is an upper limit and no lower limit in these two objectives. Therefore, the reduced half-line is chosen as their membership function, as shown in Figure 3. In the membership function, the ordinate represents the satisfaction of each subject (i.e., grid and user) and the abscissa represents the index of each subject. It can be seen from Figure 3 that the main body will eventually reach the most satisfactory level.
Two membership functions can be expressed as
μ ( f 1 ( x ) ) = 1 , if f 1 ( x ) < C 01 ; C 01 + D 01 f 1 ( x ) D 01 , if C 01 f 1 ( x ) C 01 + D 01 ; 0 , if f 1 ( x ) > C 01 + D 01 .
μ ( f 2 ( x ) ) = 1 , if f 2 ( x ) < C 02 ; C 02 + D 02 f 2 ( x ) D 02 , if C 02 f 2 ( x ) C 02 + D 02 ; 0 , if f 2 ( x ) > C 02 + D 02 .
where C 01 is the result when the minimum investment of users is taken as the optimization objective, C 02 is the result when the smoothest photovoltaic output is considered separately, C 01 + D 01 is the maximum acceptable value for user investment, and C 02 + D 02 is the maximum allowable value for the proportion of high-frequency components in the PV output. Taking λ as the smallest subordinate variable in all subordinate functions, satisfaction can be expressed as
λ = M i n : { μ ( f 1 ( x ) ) , μ ( f 2 ( x ) ) }
According to the principle of maximum membership degree, the original multi-objective optimal allocation problem can be transformed into a membership degree that satisfies all constraints, i.e., satisfaction maximum. At this time, the optimization results will comprehensively satisfy of both users and grids and can be simply represented by the following models.
M i n : λ
s . t . C 01 f 1 ( x ) + D 01 λ C 01 + D 01
C 02 f 2 ( x ) + D 02 λ C 02 + D 02
0 λ 1
Supercapacitor Operation Constraints: (4)–(9).

3.2. Two-Stage Optimization Algorithm Based on GUROBI

In summary, the specific steps of the two-stage algorithm for optimizing the configuration in this paper are as follows.
Step 1:
Input photovoltaic output data and load data
Step 2:
Determine whether the fluctuation of output data meets the grid-connected requirements, and if it meets the requirements, move to step 5. If not, adjust the fuzzy parameters, increase the investment of the supercapacitor, and return to step 2 to recalculate the filtering effect.
Step 3:
If the requirement is not met, calculate the fuzzy parameters from the viewpoint of users and power grid.
Step 4:
Establish a fuzzy optimization model to optimize the configuration of supercapacitors, verify whether the photovoltaic output after capacitance configuration meets the requirements, and return to step 2 if it does not meet the requirements.
Step 5:
Calculate user loads with the superimposed photovoltaic output if the requirements are met.
Step 6:
According to the overlapped load, establish the optimal battery allocation model under a two-part tariff.
Step 7:
Use GUROBI to solve the model and obtain the optimal configuration scheme of hybrid energy storage in the photovoltaic scenario.
Remark 1.
To achieve the two goals of reducing charging and discharging cycles and improving the user’s income, rewrite the battery optimization target as follows.
M a x : C i n v e s t 2 N
Remark 2.
To successfully solve the problem with GUROBI, as many nonlinear terms in the objective function need to be removed as possible. Therefore, the inflation term in objective functions (14), (15), and (18) is removed to simplify the optimization process. After the optimization, the results are added for analysis.

4. Case Study

The year-round load data of heavy-duty industrial users in Jiangsu Province China are chosen as an example in this paper. The specifications of batteries and supercapacitors are shown in Table 2. To simplify the model, it is assumed that the batteries are continuously optimized and that the supercapacitors are discretely optimized. The parameters of a supercapacitor are selected as Table 3, and the price of SC is CNY1218. The charge of unit electricity of demand is 40 CNY/(kW · month). The time-of-use tariff is consistent with the current system in Jiangsu.

4.1. Optimal Allocation of SC

(1)
Input the PV output data, load data, and SC price data, calculate the proportion of PV output in the total load output and SC charging and discharging behavior after MF, and obtain the minimum investment cost C 01 of SC, the maximum investment cost f 1 m a x of SC, and the high-frequency component strength after filtering.
(2)
Input the PV output data, load data and SC price data; calculate the PV output spectrum after MF and the original spectrum of PV output; and obtain the minimum allowable high-frequency ratio C 02 of PV output, the maximum high-frequency ratio f 2 m a x of PV output, and the corresponding SC investment.
(3)
According to D 01 = f 1 m a x C 01 and D 02 = f 2 m a x C 02 , substitute D 01 and D 02 into formulas (25) and (26) to obtain the membership functions, and the multi-objective optimization problems of users and power grids can be transformed into single-objective optimization. Satisfaction can be obtained using G U R O B I as Table 4.

4.2. Optimal Allocation of Batteries

The battery configuration corresponding to the maximum load is chosen to optimize the user’s load for the whole year of 2017. The upper limit of the number of battery charging and discharging cycles is set to 4000. The results of the investments and returns of users in the life cycle are shown in Table 5.

4.3. Discussion

According to the results of fuzzy optimization, the optimum degree of satisfaction is 0.82, and 296 supercapacitors need to be configured at this time. The corresponding output curve is shown in Figure 4. The curve of satisfaction of the two objectives with capacitance investment is shown in Figure 4. Figure 5 shows that due to the investment limitation of SC, there are upper and lower limits of SC output, which cannot fully achieve the effect of MF. The intersection of Figure 5 is the optimal configuration point that satisfies the grid and users.
In this paper, the typical daily load of the industrial user for 12 months is selected by a clustering algorithm.
The large daily load, medium daily load and small daily load of these 12 typical daily loads are selected and optimized, respectively. The output curves of the three kinds of loads are shown in Figure 6, Figure 7 and Figure 8. It can be seen from the figure that the peak load after energy storage adjustment was successfully reduced by 10–20%, and the energy storage was charged to reduce the overall electricity price in the late night and other low price periods.
According to the configuration results, the larger the load level is, the larger the energy storage specifications that need to be configured. Therefore, the battery configuration corresponding to the maximum load was chosen to optimize the user’s load for the whole year of 2017.
The industrial user selected in this paper shows obvious characteristics of working and non-working days. By reducing the maximum load requirement of each month, this model reduces the monthly electricity demand and improves the user’s income. Under the current hourly tariff background, the cost can be recovered after installing hybrid energy storage for 7.5 years, which shows that the model has application value and popularization significance.
Because the non-working day load has no peak and does not require energy storage regulation, the number of energy storage charging and discharging cycles throughout the year is greatly reduced. With that load characteristic, the average energy storage only needs 377 cycles in 2017, which achieves the target of minimizing the number of charge and discharge cycles so that the energy storage can be used for 10.61 years in total.

5. Conclusions

In this application scenario, supercapacitors are used to suppress the fluctuation of photovoltaic output, and batteries are used to reduce the user’s maximum load demand. The characteristics of this model are as follows.
(1)
This paper uses fuzzy optimization theory to optimize capacitor configuration from two aspects of power grid and users. Considering the benefits of users and the stability of the power grid, it can be seen from the calculation examples that both sides reach a more satisfactory state.
(2)
The whole multi-objective optimization process is divided into two stages to make the optimization process clear. In the second stage, the multi-objective optimization uses the method of dividing objective functions to ensure the user’s benefit and reduce the number of charging and discharging cycles in each CC, to improve the service life of energy storage. It can be seen from the calculation results that ES life is extended to 10.61 years after the number of CCs is determined, which successfully compensates for the investment and operation cost of ES systems and enables users to make profits.

Author Contributions

Conceptualization, Y.X.; methodology, Y.X. and Q.X.; software, Y.X.; validation, Y.X.; formal analysis, J.Z. and C.W.; writing—original draft preparation, Y.X.; writing—review and editing; supervision, Q.X.; project administration, Q.X.; funding acquisition, Q.X.

Funding

This research was funded by Chinese National Natural Science Foundation, grant number 51936003 and Chinese National Natural Science Foundation, grant number 51877044.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript.
SCsupercapacitor
chacharge
disdischarge
CNYChinese Yuan
CCCharge Cycle
PVPhotovoltaic
ESEnergy Storage
MFMedian Filter
WTWavelet Transform
MAFMoving Average Filter
SOCState of Charge

References

  1. Jiang, W.; Zhang, L.; Zhao, H.; Hu, R.; Huang, H. Research on power sharing strategy of hybrid energy storage system in photovoltaic power station based on multi-objective optimization. IET Renew. Power Gener. 2016, 10, 575–583. [Google Scholar] [CrossRef]
  2. Jayasekara, N.; Masoum, M.A.S.; Wolfs, P.J. Optimal operation of distributed energy storage systems to improve distribution network load and generation hosting capability. IEEE Trans. Sustain. Energy 2016, 7, 250–261. [Google Scholar] [CrossRef]
  3. Zhang, X.; Yuan, Y.; Hua, L.; Cao, Y.; Qian, K. On generation schedule tracking of wind farms with battery energy storage systems. IEEE Trans. Sustain. Energy 2017, 8, 341–353. [Google Scholar] [CrossRef]
  4. Yan, W.; Sheng, L.; Xu, D.; Yang, W.; Liu, Q. H∞ robust load frequency control for multi-area interconnected power system with hybrid energy storage system. Appl. Sci. 2018, 8, 1748. [Google Scholar] [CrossRef] [Green Version]
  5. Yan, N.; Zhang, B.; Li, W.; Ma, S. Hybrid energy storage capacity allocation method for active distribution network considering demand side response. IEEE Trans. Appl. Superconduct. 2018, 29, 1–4. [Google Scholar] [CrossRef]
  6. Kazemi, M.; Zareipour, H. Long-term scheduling of battery storage systems in energy and regulation markets considering battery’s lifespan. IEEE Trans. Smart Grid 2018, 9, 6840–6849. [Google Scholar] [CrossRef]
  7. Pantic, L.S.; Pavlović, T.M.; Milosavljević, D.D.; Radonjic, I.S.; Radovic, M.K.; Sazhko, G. The assessment of different models to predict solar module temperature, output power and efficiency for nis, serbia. Energy 2016, 109, 38–48. [Google Scholar] [CrossRef]
  8. Zhang, R.; Mirzaei, P.A.; Carmeliet, J. Prediction of the surface temperature of building-integrated photovoltaics: Development of a high accuracy correlation using computational fluid dynamics. Sol. Energy 2017, 147, 151–163. [Google Scholar] [CrossRef] [Green Version]
  9. Zidar, M.; Georgilakis, P.S.; Hatziargyriou, N.D.; Capuder, T.; Škrlec, A. Review of energy storage allocation in power distribution networks: Applications, methods and future research. IET Gener. Transm. Distrib. 2016, 10, 645–652. [Google Scholar] [CrossRef]
  10. Del Granado, P.C.; Pang, Z.; Wallace, S.W. Synergy of smart grids and hybrid distributed generation on the value of energy storage. Appl. Energy 2016, 170, 476–488. [Google Scholar] [CrossRef] [Green Version]
  11. Kim, W.-W.; Shin, J.-S.; Kim, J.-O. Operation strategy of multi-energy storage system for ancillary services. IEEE Trans. Power Syst. 2017, 32, 4409–4417. [Google Scholar] [CrossRef]
  12. Mohammadi, S.; Mohammadi, A. Stochastic scenario-based model and investigating size of battery energy storage and thermal energy storage for micro-grid. Int. J. Electr. Power Energy Syst. 2014, 61, 531–546. [Google Scholar] [CrossRef]
  13. Shang, C.; Srinivasan, D.; Reindl, T. An improved particle swarm optimisation algorithm applied to battery sizing for stand-alone hybrid power systems. Int. J. Electr. Power Energy Syst. 2016, 74, 104–117. [Google Scholar] [CrossRef]
  14. Song, Z.; Zhang, X.; Li, J.; Hofmann, H.; Ouyang, M.; Du, J. Component sizing optimization of plug-in hybrid electric vehicles with the hybrid energy storage system. Energy 2018, 144, 393–403. [Google Scholar] [CrossRef]
  15. Xiong, R.; Cao, J.; Yu, Q. Reinforcement learning-based real-time power management for hybrid energy storage system in the plug-in hybrid electric vehicle. Appl. Energy 2018, 211, 538–548. [Google Scholar] [CrossRef]
  16. Yorino, N.; Abdillah, M.; Sasaki, Y.; Zoka, Y. Robust power system security assessment under uncertainties using bi-level optimization. IEEE Trans. Power Syst. 2018, 33, 352–362. [Google Scholar] [CrossRef]
  17. Hesse, H.; Martins, R.; Musilek, P.; Naumann, M.; Truong, C.; Jossen, A. Economic optimization of component sizing for residential battery storage Systems. Energies 2017, 10, 835. [Google Scholar] [CrossRef]
  18. Merei, G.; Moshövel, J.; Magnor, D.; Sauer, D.U. Optimization of self-consumption and techno-economic analysis of pv-battery systems in commercial applications. Appl. Energy 2016, 168, 171–178. [Google Scholar] [CrossRef]
  19. Hu, X.; Moura, S.J.; Murgovski, N.; Egardt, B.; Cao, D. Integrated ptimization of battery sizing, charging, and power management in plug-in hybrid electric vehicles. IEEE Trans. Control Syst. Technol. 2015, 24, 1036–1043. [Google Scholar] [CrossRef] [Green Version]
  20. Sinha, A.; Malo, P.; Deb, K. A review on bilevel optimization: From classical to evolutionary approaches and applications. IEEE Trans. Evol. Comput. 2018, 22, 276–295. [Google Scholar] [CrossRef]
  21. Erdinc, O.; Paterakis, N.G.; Pappi, I.N.; Bakirtzis, A.G.; Catalão, J.P.S. A new perspective for sizing of distributed generation and energy storage for smart households under demand response. Appl. Energy 2015, 143, 26–37. [Google Scholar] [CrossRef]
  22. Leitermann, O.; Kirtley, J.L. Energy storage for use in load frequency control. In Proceedings of the 2010 IEEE Conference on Innovative Technologies for an Efficient and Reliable Electricity Supply, Waltham, MA, USA, 27–29 September 2010; pp. 292–296. [Google Scholar]
  23. Lv, P.; Liu, C.; Rao, Z. Experiment study on the thermal properties of paraffin/kaolin thermal energy storage form-stable phase change materials. Appl. Energy 2016, 182, 475–487. [Google Scholar] [CrossRef]
  24. Sanny, A.; Prasanna, V.K. Energy-efficient median filter on fpga. In Proceedings of the 2013 International Conference on Reconfigurable Computing and FPGAs (ReConFig), Waltham, MA, USA, 27–29 September 2013; pp. 1–8. [Google Scholar]
  25. Linssen, J.; Stenzel, P.; Fleer, J. Techno-economic analysis of photovoltaic battery systems and the influence of different consumer load profiles. Appl. Energy 2017, 185, 2019–2025. [Google Scholar] [CrossRef]
Figure 1. Structural chart of user-side photovoltaic hybrid energy storage model.
Figure 1. Structural chart of user-side photovoltaic hybrid energy storage model.
Applsci 09 05307 g001
Figure 2. Comparison of three filtering algorithms.
Figure 2. Comparison of three filtering algorithms.
Applsci 09 05307 g002
Figure 3. Membership function of two optimization objectives.
Figure 3. Membership function of two optimization objectives.
Applsci 09 05307 g003
Figure 4. SC output.
Figure 4. SC output.
Applsci 09 05307 g004
Figure 5. Satisfaction degree.
Figure 5. Satisfaction degree.
Applsci 09 05307 g005
Figure 6. Energy storage configuration for minimum load.
Figure 6. Energy storage configuration for minimum load.
Applsci 09 05307 g006
Figure 7. Energy storage configuration for medium load.
Figure 7. Energy storage configuration for medium load.
Applsci 09 05307 g007
Figure 8. Energy storage configuration for maximum load.
Figure 8. Energy storage configuration for maximum load.
Applsci 09 05307 g008
Table 1. High-frequency ratio.
Table 1. High-frequency ratio.
Primary Photovoltaic OutputWavelet TransformMoving Average FilteringMedian Filtering
0.39810.39530.32350.3197
Table 2. Relative parameters of the energy storage system.
Table 2. Relative parameters of the energy storage system.
Performance IndexBatterySuper Capacity
Power Cost Coefficient (CNY/kW)15001500
Capacity Cost Coefficient (CNY/kWh)100027,000
Operation Cost Coefficient (CNY/kW)0.050.05
Charging and discharging efficiency0.850.95
Range of SOC ( 0.2 , 0.8 ) ( 0.1 , 0.9 )
Table 3. Selected supercapacitor parameters.
Table 3. Selected supercapacitor parameters.
Specification ParameterNumerical Value
Capacity (F)10
Rated voltage (V)5
Rated current (A)40
Rated power (kW)0.2
Rated capacity (kWh)0.034
Table 4. Maximum satisfaction index and optimized results.
Table 4. Maximum satisfaction index and optimized results.
λ λ ( f 1 ) λ ( f 2 ) f 1 ( CNY × 10 4 ) f 2
0.390.960.3928.7960.39
0.730.730.9641.4120.33
0.520.940.5230.450.37
0.820.820.8636.540.34
Table 5. Total investment results.
Table 5. Total investment results.
ProjectEconomic Performance
Total Investment (CNY × 10 4 )396.54
Super Capacitor Investment (CNY × 10 4 )36.5
Battery Investment (CNY × 10 4 )360.04
Operation and Maintenance Investment (CNY × 10 4 )0.504
Total revenue (CNY × 10 4 )746.05
Income share of demand savings34.63%
Years of Return on Investment (year)7.49
Annual return on investment12.5%
Annual average cycle times of charge and discharge377

Share and Cite

MDPI and ACS Style

Xia, Y.; Xu, Q.; Zhao, J.; Wang, C. Two-Stage Configuration of User-Side Hybrid Energy Storage Based on Fuzzy Optimization. Appl. Sci. 2019, 9, 5307. https://doi.org/10.3390/app9245307

AMA Style

Xia Y, Xu Q, Zhao J, Wang C. Two-Stage Configuration of User-Side Hybrid Energy Storage Based on Fuzzy Optimization. Applied Sciences. 2019; 9(24):5307. https://doi.org/10.3390/app9245307

Chicago/Turabian Style

Xia, Yuanxing, Qingshan Xu, Jun Zhao, and Chengliang Wang. 2019. "Two-Stage Configuration of User-Side Hybrid Energy Storage Based on Fuzzy Optimization" Applied Sciences 9, no. 24: 5307. https://doi.org/10.3390/app9245307

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop