Article

Experimental Study on Dynamics of Wooden House Wall Panels with Different Thermal Isolation

Faculty of Civil and Environmental Engineering, Gdansk University of Technology, 80-233 Gdansk, Poland
*
Author to whom correspondence should be addressed.
Appl. Sci. 2019, 9(20), 4387; https://doi.org/10.3390/app9204387
Submission received: 4 August 2019 / Revised: 13 October 2019 / Accepted: 14 October 2019 / Published: 17 October 2019
(This article belongs to the Section Civil Engineering)

Abstract

:
Wood frame buildings are very popular in regions that are exposed to different dynamic excitations including earthquakes. Therefore, their seismic resistance is really important in order to prevent structural damages and human losses. The aim of the present paper is to show the results of experimental tests focused on the dynamic response of wall panels of a wooden frame building with thermal isolation made of mineral wool and polyurethane foam. Firstly, the static and the dynamic mechanical analysis (DMA) tests were conducted so as to determine the basic thermomechanical properties of the analyzed isolation materials. Then, the elements of the exterior walls with two types of thermal insulation were tested under harmonic excitation for different amplitudes of displacement. The results of the static material tests indicate that the polyurethane foam behaves in a highly nonlinear way both during compression and tension. Moreover, the results of the DMA tests show that the storage and loss modulus of the polyurethane foam are significantly larger in relation to the values obtained for the mineral wool. The results of the dynamic tests on wall panels show that the use of polyurethane foam as thermal isolation leads to a substantial increase in stiffness and damping properties, as compared to the case when the mineral wood is used.

1. Introduction

The seismic resistance of civil engineering structures, especially buildings, is an important aspect related to structural safety in the event of an earthquake [1,2,3]. Damages to building structures are the most common cause of fatalities due to seismic excitation. This applies to structures erected with different technologies.
Buildings of major importance, such as hospitals, facilities of fire brigades or crisis management centres are designed in accordance with the applicable standards [4]. Methods of strengthening these structures, mainly constructed of reinforced concrete or steel frame (for example using the fiber-reinforced cementitious composite [4]), are subjected to many tests, including experimental and numerical ones [5,6,7,8,9]. There are many methods of retrofitting masonry structures, including methods for strengthening cracked walls using high-strength composite materials and a rigid adhesive with low deformability [10,11,12,13,14]. The concept of increasing the effectiveness of secondary structural elements in the overall seismic behaviour of buildings has also been investigated; for example, the application of special mechanical connectors interposed at the interface between a multi-storey building and the glazing facade [15]. The results of the study indicate that, once the input parameters of the connecting devices are properly designed, the glazing facade may work as an effective passive control system for the primary structure [15].
An increasing number of newly constructed wooden frame buildings has also been recently observed. The technology is popular both in rich and poor countries. Properly designed wooden structures are inherently well resistant to dynamic loads, such as extreme earthquakes [16]. The current research concerning wooden buildings is focused, among others, on forecasting the occurrence of damage and monitoring the critical structural elements during seismic shocks [17,18]. The research work includes both experimental investigations, including the shaking table tests (see [19,20]), as well as numerical analyses. A number of studies have been focused on structural connectors, anchor connections and special flat bars and angles, the use of which results in stiffening of the whole structure and increasing its seismic resistance [21,22,23]. The role of connections, with the lateral deformation of the light walls and with q-factor, has also been investigated (for example, see [24,25,26,27,28]).
In addition, the low construction cost is one of the most popular and well-known advantages of wooden buildings. This is due to the relatively good availability of building material in many parts of the world and ease of assembly related to technical aspects (heavy equipment is not required), as well as assembly time and good usability parameters (aesthetics, easy repairs and modifications, good climate, etc.). However, one of the most important technological elements in a wooden frame is the application and proper arrangement of thermal insulation. Thermal insulation affects the lifespan and durability of the building, and defines the energy class [29]. Unlike other elements of a wooden frame building, the results of research focused on thermal insulation are relatively limited. One of a few examples concerns a study on the seismic efficiency of structural insulated panels [30]. The behaviour of wood-composite laminated frames under the dynamic loads has also been investigated [31].
There are some numerical analyses available, which indicate that thermal insulation of the wooden frame building can substantially affect the dynamic resistance of the whole structure (for example, see [32,33]). The results of these analyses show that using polyurethane foam instead of mineral wool for the in-wall insulation of a wood-frame building leads to an increase in the rigidity of the whole structure. This effect is obtained mainly due to full connection between the polyurethane foam and the surrounding wooden elements, and a lack of such connection in the case of mineral wool. It has been found that the increase in the rigidity of the building insulated with the polyurethane foam leads to the substantial reduction in the structural response under different seismic excitations [33]. It should be added that, in construction, polyurethane foam is known only as an insulation material. It turns out that this insulation material can also effectively stiffen the whole structure and improve its dynamic resistance substantially. However, the results of the numerical analyses described in [32,33] have to be verified experimentally.
Therefore, the aim of the present study is to show the results of experimental tests focused on the dynamic response of wall panels of a wooden frame building with thermal isolation made of traditional mineral wool and polyurethane foam. Firstly, the static and the dynamic mechanical analysis (DMA) tests were conducted so as to determine the basic thermomechanical properties of the analyzed isolation materials. Then, the elements of exterior walls with two types of thermal insulation were tested under harmonic excitation for different amplitudes of displacement.

2. Static Material Tests

Firstly, static compression and tension tests were carried out for the polyurethane foam (because of the mechanical parameters of mineral wool and the problem with fixing the samples, tests for this material were not possible). The tests were conducted using a two-column Zwick/Roell Z020 machine with a maximum force range of 20 kN.
Polyurethane foam static compression tests were carried out on a number of cylindrical samples with a cross-section area of 18 mm2 and a height of 20 mm (Figure 1). Material samples were taken directly from the wall panels of the wooden frame building, which were previously tested experimentally (see Section 4). The representative results of the static compression tests, in the form of relation between stress and strain, are shown in Figure 2. It should be added that nearly identical curves were obtained for all of the tested samples and the scatter of the results was negligibly small. It can be seen from Figure 2 that the foam behaves in a highly nonlinear way during compression. In the range of elongation from 0 to about 0.1, stresses increase up to about 250 kPa. Then, at the deformation above about 0.1, stabilization occurs, and above this range of strains, the stresses remain almost constant.
Polyurethane foam static tension tests were carried out on a number of samples with a cross-section of 10 mm2 and a height of 80 mm (Figure 3). Material samples were taken directly from the wall panels of the wooden frame building, which were previously tested experimentally (see Section 4). The representative results of the static tension tests, in the form of relation between stress and strain, are shown in Figure 4. It should be added that nearly identical curves were obtained for all of the tested samples and the scatter of the results was negligibly small. It can be seen from Figure 4 that the foam behaves in a highly nonlinear way also during tension. In the strain range from 0 to about 0.05, the stresses increase nonlinearly up to about 43 kPa. In the strain interval above 0.05, the stresses increase almost linearly to the level of about 105 kPa.

3. DMA Material Tests

In the second stage of investigation, dynamic mechanical spectroscopy tests were performed using the DMA Q800 Instruments apparatus (Figure 5 and Figure 6). The parameters of tests are presented in Table 1. It should be underlined that the range of temperatures and frequencies corresponded to real conditions. The loading protocol was taken according to standards ASTM D4092 and DIN 53440.
The results of the DMA tests (compression tests) are presented in Figure 7, Figure 8, Figure 9, Figure 10, Figure 11, Figure 12, Figure 13 and Figure 14 and are summarized in Table 2 and Table 3. The results show the change of storage modulus, loss modulus and loss factor (tan delta) as the temperature increases. It should be mentioned that the storage modulus measures the stored energy in the material due to the applied strain and represents the elastic portion of energy [34]. On the other hand, the loss modulus measures the energy dissipated through molecular motion and represents the viscous portion of energy. The ratio of the loss modulus to storage modulus is termed as the loss factor [34].
The results of DMA tests (see Figure 7, Figure 8, Figure 9, Figure 10, Figure 11, Figure 12, Figure 13 and Figure 14) clearly show that the values of storage and loss modulus were substantially larger for the polyurethane foam, as compared to the mineral wool. In particular, it can be seen from Table 2 and Table 3 that, for the case of the temperature of 20 °C, the storage modulus of the polyurethane foam was larger by as much as 91.7%, 76.8% and 77.4% for the frequencies of 1 Hz, 10 Hz and 20 Hz, respectively. In turn, the loss modulus of the polyurethane foam was bigger than the corresponding value for the mineral wool by as much as 61.4%, 74.5% and 88.3% for the frequencies of 1 Hz, 10 Hz and 20 Hz, respectively. This indicates that the polyurethane foam, as a material, was able to dissipate a larger amount of energy. Therefore, comparing it to the mineral wool, it is a material with much better absorption capabilities related directly to the energy absorption.

4. Dynamic Tests on Wall Panels

In the final stage of investigation, dynamic tests for real size wall panels of the wooden frame house were carried out for two variants of skeleton filling.

4.1. Experimental Setup

The specially designed experimental setup was used to perform the tests (see Figure 15 and Figure 16). It was constructed using a steel frame with dimensions of 300 cm by 50 cm that was fixed to the floor slab. The additional mounting socket, with dimensions of 150 cm by 60 cm, was welded to the main frame to be used for installation of the wall panels (Figure 17). The dynamic actuator Parker ETB125, with the displacement range of ±25 cm, peak acceleration of 10 m/s2 and maximum force of 45 kN was installed on one side of the frame (Figure 17). The parameters of the designed setup enabled destructive testing of wooden wall elements, being at the same time strictly adapted to the dimensions of the tested elements.
For the purpose of this study, a typical wooden frame house set of wall panels were prepared (see Figure 17). Using a modulus of 60 cm for the frame elements, each panel was constructed with C24 wood, filled either with mineral wool or polyurethane foam, and covered on both sides by OSB3 (Oriented Strand Board) sheaths. The dimensions of each panel were 129 cm in length and 60 cm in width. Wooden skeleton elements (posts and cap) were connected to each other using standard screws. Screws were also applied to connect the OSB3 sheaths and the skeleton itself. In this case, the connectors were used at the corners and along the length of the board at intervals of 10 cm. Since the skeleton was covered by the single OSB3 boards on both sides (see Figure 17), there was no need to apply any connectors in the middle of the element. Material properties of different elements used in the panels are shown in Table 4.
One side of each of the tested panel was fixed to the experimental stand using 10 mm bolts, while the movement of the second side was allowed in the horizontal direction (buckling was prevented by special blocking system; see Figure 17).

4.2. Results

During experimental tests, both models were subjected to harmonic excitations. The tests were conducted at a frequency of 2 Hz for different values of displacement amplitude. Measurements were carried out with the sampling frequency of 500 kHz using Alitec VIMEA VE 16BCA measuring system. The exerted force was recorded by a force sensor KMM40, working in the range of up to 50 kN, the accuracy class of 0.5 and sampling frequency of 200 Hz (according to the producer’s specification). The resulting displacement was measured by a laser displacement sensor optoNCDT1302, working in the range of ±100 mm with the micrometre accuracy and sampling frequency of 750 Hz (according to the producer’s specification). The force sensor was mounted at the end of the actuator’s moveable rod, while the displacement sensor was installed at the actuator’s shaft (see Figure 17).
In the first stage of the tests, a wall panel with a skeleton filled with mineral wool was mounted on the stand. The results, in the form of representative hysteresis loops showing the relation between force and displacement, are presented in Figure 18. On this basis, the stiffness, K , and damping ratio, ξ , were calculated using the following formulas (see also Figure 19) [35]:
K = F ( x e ) F ( x e ) 2 · x e
ξ = Δ W 2 π · F ( x e ) · x e
The results are shown in Table 5. It should also be added that the tests for this element were destructive and could not be carried out for the amplitude of displacement larger than 28 mm. For such amplitude, OSB3 sheathing began to detach from the skeleton, and connectors became loose leading to delamination of the panel (see Figure 20).
In the second stage of the tests, a wall panel filled with the polyurethane foam was installed on the stand. Then, the experiments were carried out for the same scheme as for the panel filled with the mineral wool. The results, in the form of representative hysteresis loops, are presented in Figure 21. On this basis, the stiffness and damping ratio were calculated using Equations (1) and (2) and the results are shown in Table 6. It should also be underlined that the structure of the element filled with the polyurethane foam passed all the tests without any damages. The only damages were concentrated in screws fixing the panel to the stand which were destroyed when the amplitude of displacement was larger than 50 mm (see Figure 22).

5. Conclusions

The dynamic response of wall panels of a wooden frame building with two variants of insulation, mineral wool and polyurethane foam, has been experimentally studied. Firstly, the static compression and tension tests were conducted for the polyurethane foam. Then, the DMA tests were carried out so as to determine the basic thermomechanical properties of both analyzed isolation materials (mineral wool and polyurethane foam). Finally, the elements of exterior walls with two types of thermal insulation were tested under harmonic excitation for different amplitudes of displacement. On this basis, stiffness and damping ratios were calculated.
Based on the results of the study, the following conclusions can be drawn:
  • Polyurethane foam behaves in a highly nonlinear way both during static compression and tension.
  • Storage modulus of the polyurethane foam is significantly larger in relation to the value obtained for the mineral wool.
  • Loss modulus of the polyurethane foam is much larger compared to the modulus of the mineral wool.
  • Polyurethane foam, as a material, is able to absorb a greater amount of energy. Comparing it to the mineral wool, it is a material with much better energy absorption capabilities.
  • The use of polyurethane foam as thermal isolation leads to a substantial increase in stiffness and damping properties of wall panels, compared to the mineral wood.
  • The panel filled with the polyurethane foam passed all the tests without any damages, whereas the tests for the panel with the mineral wood were destructive.
  • The use of polyurethane foam caused the integration of individual elements of the panel allowing it to behave as one element, increasing its strength and spatial rigidity.
  • Damping properties of the polyurethane foam contributed to an increase in the dynamic resistance of the panel, since larger amount energy could be dissipated.
Taking into account the above arguments, it is recommended to apply the polyurethane foam not only as an isolation material but also to increase the dynamic resistance of skeletal wooden structures. It can be used for newly constructed houses. It can also be applied in the case of existing wood-frame buildings since replacing the mineral wool with the polyurethane foam is relatively easy. The results of the investigation shown in this paper indicate that such an approach would be a very effective method of increasing the dynamic resistance of existing structures. Moreover, the polyurethane foam is a material widely available and increasingly used in civil engineering. It is also a relatively inexpensive and durable material compared to other insulation materials, which also makes it very attractive.

Author Contributions

Conceptualization, M.S. and R.J.; data curation, M.S.; formal analysis, M.S., W.M., and R.J.; methodology, M.S. and R.J.; writing—original draft, M.S. and W.M.; writing—review and editing, R.J.

Funding

This research received no external funding.

Acknowledgments

The authors would like to thank Maciej Wysokiński from STOLKAL Company for supplying the specimens used in the tests, as well as Bohdan Kowalewski and Łukasz Piszczyk for their help during the tests.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Migda, W.; Jankowski, R. An approach for the response of buildings subjected to impact load after soft-story failure due to earthquake excitation. Shock Vib. 2013, 20, 681–692. [Google Scholar] [CrossRef]
  2. Jankowski, R. Pounding between superstructure segments in multi-supported elevated bridge with three-span continuous deck under 3D non-uniform earthquake excitation. J. Earthq. Tsunami 2015, 9, 1550012. [Google Scholar] [CrossRef]
  3. Jankowski, R.; Mahmoud, S. Linking of adjacent three-storey buildings for mitigation of structural pounding during earthquakes. Bull. Earthq. Eng. 2016, 14, 3075–3097. [Google Scholar] [CrossRef] [Green Version]
  4. Li, X.; Wang, J.; Bao, Y.; Chen, G. Cyclic behavior of damaged reinforced concrete columns repaired with high-performance fiber-reinforced cementitious composite. Eng. Struct. 2017, 136, 26–35. [Google Scholar] [CrossRef]
  5. ECS. Eurocode 8: Design Provisions for Earthquake Resistance of Structures; European Committee for Standardization: Brussels, Belgium, 1998. [Google Scholar]
  6. Teng, J.G.; Yu, T.; Fernando, D. Strengthening of steel structures with fiber-reinforced polymer composites. J. Constr. Steel Res. 2012, 78, 131–143. [Google Scholar] [CrossRef]
  7. Linghoff, D.; Haghani, R.; Al-Emrani, M. Carbon-fibre composites for strengthening steel structures. Thin Walled Struct. 2009, 47, 1048–1058. [Google Scholar] [CrossRef]
  8. Kim, D.H.; Moon, D.Y.; Kim, M.K.; Zi, G.; Roh, H. Experimental test and seismic performance of partial precast concrete segmental bridge column with cast-in-place base. Eng. Struct. 2015, 100, 178–188. [Google Scholar] [CrossRef]
  9. Shrive, N.G. The use of fibre reinforced polymers to improve seismic resistance of masonry. Constr. Build. Mater. 2006, 20, 269–277. [Google Scholar] [CrossRef]
  10. Kwiecień, A. Strengthening of masonry using natural fibers bonding with highly deformable adhesives. J. Eng. Technol. 2015, 3, 103–114. [Google Scholar]
  11. Falborski, T.; Jankowski, R.; Kwiecień, A. Experimental study on polymer mass used to repair damaged structures. Key Eng. Mater. 2012, 488–489, 347–350. [Google Scholar] [CrossRef]
  12. Kasal, B.; Polocoser, T.; Guindos, P.; Urushadze, S.; Pospisil, S.; Heiduschke, A.; Ruther, N.; Zembaty, Z. High performance composite-reinforced earthquake resistant buildings with self-aligning capabilities. Geotechnical. Geol. Earthq. Eng. 2015, 235, 359–372. [Google Scholar]
  13. Meng, W.; Khayat, K.H.; Bao, Y. Flexural behaviors of fiber-reinforced polymer fabric reinforced ultra-high-performance concrete panels. Cem. Concr. Compos. 2018, 93, 43–53. [Google Scholar] [CrossRef]
  14. Meng, W.; Khayat, K.H. Development of stay-in-place formwork using GFRP reinforced UHPC elements. In Proceedings of the First International Interactive Symposium on UHPC, Des Moines, IA, USA, 18–20 July 2016; pp. 1–9. [Google Scholar]
  15. Bedon, C.; Amadio, C. Enhancement of the seismic performance of multi-storey buildings by means of dissipative glazing curtain walls. Eng. Struct. 2017, 152, 320–334. [Google Scholar] [CrossRef] [Green Version]
  16. Toratti, T. Design guidance on Eurocode 8 for practicing engineers for timber structures. In International Workshop on Earthquake Engineering on Timber Structures; University of Coimbra: Coimbra, Portugal, 2006; pp. 55–70. [Google Scholar]
  17. Toratti, T. Seismic Design of Timber Structures; FEMA: Espoo, Finland, 1994.
  18. Liang, H.; Wen, Y.-K.; Foliente, G.C. Damage modeling and damage limit state criterion for wood-frame buildings subjected to seismic loads. J. Struct. Eng. 2011, 137, 41–48. [Google Scholar] [CrossRef]
  19. Heiduschke, A.; Kasal, B.; Haller, P. Shake table tests of small-and full-scale laminated timber frames with moment connections. Bull. Earthq. Eng. 2009, 7, 323–339. [Google Scholar] [CrossRef]
  20. Filiatrault, A.; Christovasilis, I.P.; Wanitkorkul, A.; Wan de Lindt, J.W. Experimental seismic response of a full-scale light-frame wood building. J. Struct. Eng. 2010, 136, 246–254. [Google Scholar] [CrossRef]
  21. Dujic, B.; Zarnic, R. Study of lateral resistance of massive X-lam wooden wall system subjected to horizontal loads. In International Workshop on Earthquake Engineering on Timber Structures; University of Coimbra: Coimbra, Portugal, 2006; pp. 97–104. [Google Scholar]
  22. Fournely, E.; Lamadon, T. Design detailing for earthquake engineering application for timber structures. In International Workshop on Earthquake Engineering on Timber Structures; University of Coimbra: Coimbra, Portugal, 2006; pp. 71–80. [Google Scholar]
  23. Vessby, J. Analysis of Shear Walls for Multi-Storey Timber Buildings; Linnaeus University Dissertations: Växjö, Sweden, 2011. [Google Scholar]
  24. González Fueyo, J.L.; Dominguez, M.; Cabezas, J.A.; Rubio, M.P. Design of connections with metal dowel-type fasteners in double shear. Mater. Struct. 2009, 42, 385–397. [Google Scholar] [CrossRef]
  25. Echavarría, C.; Salenikovich, A. Analytical model for predicting brittle failures of bolted timber joints. Mater. Struct. 2009, 42, 867–875. [Google Scholar] [CrossRef]
  26. Miller, J.F.; Schmidt, R.J.; Bulleit, W.M. New yield model for wood dowel connections. J. Struct. Eng. 2010, 136, 1255–1261. [Google Scholar] [CrossRef]
  27. Germano, F.; Metelli, G.; Giuriani, E. Experimental results on the role of sheathing-to-frame and base connections of a European timber framed shear wall. Constr. Build. Mater. 2015, 80, 315–328. [Google Scholar] [CrossRef]
  28. Gattesco, N.; Boem, I. Seismic performances and behavior factor of post-and-beam timber buildings braced with nailed shear walls. Eng. Struct. 2015, 100, 674–685. [Google Scholar] [CrossRef]
  29. Nitka, W. My Wooden House; National Forest Information Centre: Warsaw, Poland, 2010. [Google Scholar]
  30. Donovan, T.; Memari, M. Feasibility study of determination of seismic performance factors for structural insulated panels. J. Archit. Eng. 2015, 21, 1–9. [Google Scholar] [CrossRef]
  31. Kasal, B.; Heiduschke, A.; Haller, P. Analysis of wood-composite laminated frames under dynamic loads—Analytical models and model validation. Part I: Connection Model. Prog. Struct. Eng. Mater. 2006, 8, 103–110. [Google Scholar]
  32. Szczepański, M.; Migda, W.; Jankowski, R. Modal analysis of real timber frame houses with different insulation materials. Adv. Sci. Technol. Res. J. 2016, 10, 215–221. [Google Scholar] [CrossRef]
  33. Szczepański, M.; Migda, W.; Jankowski, R. Increasing the seismic resistance of wood-frame buildings by applying PU foam as thermal insulation. Period. Polytech. Civ. Eng. 2019, 63, 480–488. [Google Scholar]
  34. Kumar, A.; Gupta, R.K. Fundamentals of Polymer Engineering; Marcel Dekker: New York, NY, USA, 2003. [Google Scholar]
  35. Falborski, T.; Jankowski, R. Advanced hysteretic model of a prototype seismic isolation system made of polymeric bearings. Appl. Sci. 2018, 8, 400. [Google Scholar] [CrossRef]
Figure 1. Samples made of polyurethane foam subjected to static compression.
Figure 1. Samples made of polyurethane foam subjected to static compression.
Applsci 09 04387 g001
Figure 2. Relation between stress and strain for polyurethane foam subjected to static compression (average of tested specimens).
Figure 2. Relation between stress and strain for polyurethane foam subjected to static compression (average of tested specimens).
Applsci 09 04387 g002
Figure 3. A sample made of polyurethane foam subjected to static tension.
Figure 3. A sample made of polyurethane foam subjected to static tension.
Applsci 09 04387 g003
Figure 4. Relation between stress and strain for polyurethane foam subjected to static tension (average of tested specimens).
Figure 4. Relation between stress and strain for polyurethane foam subjected to static tension (average of tested specimens).
Applsci 09 04387 g004
Figure 5. Test setup with dynamic mechanical analysis (DMA) Q800 analyzer.
Figure 5. Test setup with dynamic mechanical analysis (DMA) Q800 analyzer.
Applsci 09 04387 g005
Figure 6. Mounting of polyurethane foam in DMA Q800 analyzer.
Figure 6. Mounting of polyurethane foam in DMA Q800 analyzer.
Applsci 09 04387 g006
Figure 7. Results of DMA tests for mineral wool for frequency 1 Hz.
Figure 7. Results of DMA tests for mineral wool for frequency 1 Hz.
Applsci 09 04387 g007
Figure 8. Results of DMA tests for mineral wool for frequency 10 Hz.
Figure 8. Results of DMA tests for mineral wool for frequency 10 Hz.
Applsci 09 04387 g008
Figure 9. Results of DMA tests for mineral wool for frequency 20 Hz.
Figure 9. Results of DMA tests for mineral wool for frequency 20 Hz.
Applsci 09 04387 g009
Figure 10. Results of DMA tests for mineral wool; comparison for all frequencies analyzed.
Figure 10. Results of DMA tests for mineral wool; comparison for all frequencies analyzed.
Applsci 09 04387 g010
Figure 11. Results of DMA tests for polyurethane foam for frequency 1 Hz.
Figure 11. Results of DMA tests for polyurethane foam for frequency 1 Hz.
Applsci 09 04387 g011
Figure 12. Results of DMA tests for polyurethane foam for frequency 10 Hz.
Figure 12. Results of DMA tests for polyurethane foam for frequency 10 Hz.
Applsci 09 04387 g012
Figure 13. Results of DMA tests for polyurethane foam for frequency 20 Hz.
Figure 13. Results of DMA tests for polyurethane foam for frequency 20 Hz.
Applsci 09 04387 g013
Figure 14. Results of DMA tests for polyurethane foam; comparison for all frequencies analyzed.
Figure 14. Results of DMA tests for polyurethane foam; comparison for all frequencies analyzed.
Applsci 09 04387 g014
Figure 15. Sketch of experimental setup (side view of the main frame).
Figure 15. Sketch of experimental setup (side view of the main frame).
Applsci 09 04387 g015
Figure 16. Sketch of experimental setup (top view of the main frame).
Figure 16. Sketch of experimental setup (top view of the main frame).
Applsci 09 04387 g016
Figure 17. Experimental setup with installed panel.
Figure 17. Experimental setup with installed panel.
Applsci 09 04387 g017
Figure 18. Hysteresis loops for the panel filled with mineral wool.
Figure 18. Hysteresis loops for the panel filled with mineral wool.
Applsci 09 04387 g018
Figure 19. Hysteresis loop.
Figure 19. Hysteresis loop.
Applsci 09 04387 g019
Figure 20. Panel filled with mineral wool after the tests.
Figure 20. Panel filled with mineral wool after the tests.
Applsci 09 04387 g020
Figure 21. Hysteresis loops for the panel filled with polyurethane foam.
Figure 21. Hysteresis loops for the panel filled with polyurethane foam.
Applsci 09 04387 g021
Figure 22. Panel filled with polyurethane foam after the tests.
Figure 22. Panel filled with polyurethane foam after the tests.
Applsci 09 04387 g022aApplsci 09 04387 g022b
Table 1. Parameters of DMA tests.
Table 1. Parameters of DMA tests.
ParameterSpecification
Dimensions of the test sampleCylinder with a height of 10 mm and a diameter of 12 mm
Frequency rangeFrom 1 Hz to 20 Hz
Heating speed4 °C/min
Temperature rangeFrom −30 °C to +50 °C
Table 2. Summary of DMA tests results for mineral wool for temperature of 20 °C.
Table 2. Summary of DMA tests results for mineral wool for temperature of 20 °C.
Frequency [Hz]Storage Modulus [kPa]Loss Modulus [kPa]Tan Delta
12.101.810.86
107.650.650.10
208.450.250.025
Table 3. Summary of DMA tests results for polyurethane foam for temperature of 20 °C.
Table 3. Summary of DMA tests results for polyurethane foam for temperature of 20 °C.
Frequency [Hz]Storage Modulus [kPa]Loss Modulus [kPa]Tan Delta
125.554.700.175
1033.002.550.07
2037.502.150.055
Table 4. Material properties of different elements used in the wooden frame house wall panels.
Table 4. Material properties of different elements used in the wooden frame house wall panels.
ElementMaterialDensity [kg/m3]Elasticity Modulus [GPa]
FrameWood of class C24509.811—along fibres
0.37—across fibres
SheathingOSB3713.81.98—along fibres
4.93—across fibres
Filling 1Mineral wool390.0005
Filling 2Polyurethane foam260.01
Table 5. Values of stiffness and damping ratio for the panel filled with mineral wool.
Table 5. Values of stiffness and damping ratio for the panel filled with mineral wool.
Frequency [Hz]Stiffness [kN/m]Damping Ratio [%]
2.0416.6617.09
Table 6. Values of stiffness and damping ratio for the panel filled with polyurethane foam.
Table 6. Values of stiffness and damping ratio for the panel filled with polyurethane foam.
Frequency [Hz]Stiffness [kN/m]Damping Ratio [%]
2.0549.5822.25

Share and Cite

MDPI and ACS Style

Szczepański, M.; Migda, W.; Jankowski, R. Experimental Study on Dynamics of Wooden House Wall Panels with Different Thermal Isolation. Appl. Sci. 2019, 9, 4387. https://doi.org/10.3390/app9204387

AMA Style

Szczepański M, Migda W, Jankowski R. Experimental Study on Dynamics of Wooden House Wall Panels with Different Thermal Isolation. Applied Sciences. 2019; 9(20):4387. https://doi.org/10.3390/app9204387

Chicago/Turabian Style

Szczepański, Marcin, Wojciech Migda, and Robert Jankowski. 2019. "Experimental Study on Dynamics of Wooden House Wall Panels with Different Thermal Isolation" Applied Sciences 9, no. 20: 4387. https://doi.org/10.3390/app9204387